FVY-86-105, Part 21 Rept Re Design Defect Relating to Limitorque Motor Operators Mfg Prior to 1975.Mfg Contacted & Retrofit Kits Installed on safety-related & nonsafety-related Operators. Addl Info Encl10 November 1986Part 21 Rept Re Design Defect Relating to Limitorque Motor Operators Mfg Prior to 1975.Mfg Contacted & Retrofit Kits Installed on safety-related & nonsafety-related Operators. Addl Info Encl
LD-84-063, Part 21 Rept Re Evaluation & Corrective Action for Excessive Setpoint Drift in Some Potentiometers in Auxiliary Feedwater Actuation Sys Cabinet at St Lucie Unit 2 & Plant Protection Sys Cabinets at Palo Verde26 October 1984Part 21 Rept Re Evaluation & Corrective Action for Excessive Setpoint Drift in Some Potentiometers in Auxiliary Feedwater Actuation Sys Cabinet at St Lucie Unit 2 & Plant Protection Sys Cabinets at Palo Verde
ML17223A74526 January 1990Part 21 Rept Re Backup Rings Furnished in Spare Parts Seal Kits & in 25 Gpm 4 Way Valves as Part of Actuators Made of Incorrect Matl.Rings Should Be Viton & Have Been Identified as Buna N
ML17261A53018 June 1987Part 21 Rept Re Potential Util Failure to Comply W/Component Containment Isolation Licensing Commitment If Proposed Mods to Component Cooling Water Sys Instituted.Utils Advised to Evaluate Containment Isolation Sys
ML18093A8286 May 1988Part 21 & Deficiency Rept Re Asea Brown Boveri,Power Distribution,Inc Low Voltage K-Line Circuit Breakers. Efforts Underway to Define Quantity & Type of Component Parts That May Need to Be Replaced
ML18153C1012 February 1990Part 21 Rept Re Two of Three Pc Cards in GE Type SLV11A1 Over/Undervoltage Relays Failing to Produce Output.Short Between Leads Would Result in Damage to Component 1C5. Sketch of Threshold Detection Board Encl
ML19207B12215 August 1979Interim Deficiency Rept Re Questionable QA Documentation on Steel Received from Glazer Steel & Aluminum.Glazer Removed from List of Approved Suppliers of Certified Matl.Final Rept Anticipated by 800216
ML19207B15616 August 1979Final Deficiency Rept Re Defective Type GE SB-12 Auxiliary Switches in safety-related Switchgear.Caused by Worn Die Used to Form Holes in Contact Arms of Switches.Elongated Holes Resulted in Improper Contact Wipe
ML19207B97730 August 1979First Interim Deficiency Rept Re Containment Anchor Bolt Chain Weld Deficiencies.Caused by Breakdown in Institution of Welding Qa/Qc Program Due to Misunderstanding of Weld Acceptance Criteria by Some Inspectors
ML19207C00529 August 1979Final Deficiency Rept Re GE Design of safety-relief Valve Control Sys.Caused by Assumption That Containment Loads Were Sufficiently Low from safety-relief Valve Discharges to Be Classified as Secondary Loads.Ge Mods Will Be Implemented
ML19209B5581 October 1979Forwards Interim Rept on Unacceptable Bending of Welded Stud Anchors on Embedded Plates.Caused by Const Forces Not Following Design Drawings.Testing Program Being Initiated to Determine Effects of Bending
ML19209B5611 October 1979Forwards Interim Rept on Faulty Welding by Lakeside Bridge & Steel on Drywall Vent Structure & Reactor Pressure Vessel Pedestal.Caused by Unacceptable Work & Copper Containment. Defective Buttering & Pedestal Cracking Will Be RepairedNondestructive Examination
Earthquake
Liquid penetrant
ML19209C89911 October 1979Final Deficiency Rept Re Invalid Heat Treatment of Reactor Pressure Vessel Pedestal Studs.Studs Fabricated by Acimet Mfg Co in Lots Exceeding ASME Requirements.Caused by Error on Purchase Order in Specs for Heat Treated MatlTime of Discovery
ML19209D1331 October 1979Final Deficiency Rept Re Faulty Welding by Lakeside Bridge & Steel on Drywell Structure & Reactor Pressure Vessel Pedestal.Caused by Unacceptable Work as Result of Insufficient Nondestructive ExamEarthquake
Liquid penetrant
ML19209D1811 October 1979Interim Deficiency Rept Re Unacceptble Bending of Welded Anchor Studs on Embedded Plates.Another Rept Will Be Forwarded by 800601
ML19210D09113 August 1979Second Interim Deficiency Rept:On 790507,general R&D Program Tests Revealed Cracking of heat-affected Zone of Welded Stud Anchors.Final Rept by 791221
ML19210D14126 October 1979Final Deficiency Rept Re Tensile Anchor Capacities Lower than Assumed in Design Allowables.Progressive Cracking Occurred in Welded Stud Anchors.Plate Flexibility Problems Eliminated by Use of Knee Brace Brackets
ML19210D34816 November 1979Interim Rept 1:on 791019,excessive Base Metal Was Removed in Piping Assembly Elbows.Caused by Grit Blasting W/O Use of Diffuser or Deflection Shields.Piping Assemblies Being Surveyed.Final Rept Will Be Submitted 800131
ML19241A7941 June 1979Deficiency Rept:During Period 780705-0915,essential Svc Water Spray Pond Central & Support Earthfill Placed W/Moisture Content Outside Acceptable Limits.Caused by Mathematical Errors in Computation.Qc Manual Revised
ML19242D2055 July 1979First Interim Deficiency Rept Re Faulty Welding by Lakeside Bridge & Steel Co on Drywell Vent Structure & Reactor Pressure Vessel Pedestal.Cracks Observed Near Weld Joints. Investigation & Repairs UnderwayEarthquake
Liquid penetrant
ML19249A55516 August 1979Final Rept Re Use of non-ASME Components on Primary Containment Personnel Access Airlocks.Caused by Vendor Interpretation of GE Specification 300-13.Airlock Sys Will Be Redesigned & Refabricated
ML19249E39929 June 1979Final Deficiency Rept on Breakdown in QC Program at Industrial Engineering Works Re Reactor Pressure Vessel Shield Wall.Faulty Butter Welds Will Be Repaired at Const Site
ML19250C58821 November 1979First Interim Deficiency Rept Re Rebar Bending.Partially Embedded Rebar May Develop Cracks During Bending by Plant Const Employees.Caused by Nonimplementation of Rebar Bending Tech Specs.Procedures Revised
ML19256A23118 October 1978Third Interim Rept Re Purchase Requests Issued W/O IEEE Qualifications Specs.Procurement Requests for Process Flow Equip Have Been Rev & Sent to Vendors.Investigation Continues
ML19256E50815 October 1979Supplemental Rept to Final Interim Deficiency Rept Re Blown 3-amp Fuses in Low Voltage Switchgear.Westinghouse Unable to Determine Cause;Requested to Continue Investigation
ML19257A2816 December 1979Final Rept Re Pressure Testing of Fuel Pool Cooling & Cleanup Sys Piping for All Units Above Aci 318-71 Limits. Portions of Two 2-inch Pipes Tested Above Limits.Caused by Designer Failure to Specify Alternate Testing
ML19257A2846 December 1979Final Deficiency Rept:On 791111,notified Region Re Use of Incorrect Weld Acceptance Criteria on Reactor Pressure Vessel Pedestal Welds.Radiographs of Welds re-evaluated W/Proper Aws CriteriaEarthquake
ML19257A33112 December 1979Second Interim Deficiency Rept Re Use of Incorrect Concrete Mix in Shield Bldg Wall.Final Rept Will Be Forwarded by 800314
ML19257A78931 December 1979Final Deficiency Rept Re Condensate Header Vortex Breakers Omitted from Piping Arrangement Drawings.Caused by Failure to Transfer Vortex Breakers as Shown on CF Braun & Co Drawing.Hartsville Unit 1 Will Have Breakers Installed
ML19257B91711 January 1980Second Interim Deficiency Rept Re Containment Anchor Bolt Chair Weld.Evaluation Revealed That Deficiencies Were Isolated Condition & That Overall Weld Insp Program Is Adequate.Will Submit Final Rept by 800319
ML19260D05131 January 1980Final Deficiency Rept Re Grit Blasting of Fabricated Piping Assemblies.Caused by Operator Sandblasting W/O Diffusers. Straight Nozzle Will Be Locked in Tool Box Under Control of Sandblast Operator
ML19261D53525 May 1979Deficiency Rept on 790525:piping Elbows Constructed from Unspecified Matl.Elbows W/Heat Code W6719 Were Identified, Tested & Returned to Manufacturer
ML19262C3651 February 1980Final Deficiency Rept Re Rebar Not Bending in Accordance W/ Site Procedures.Affected Const Personnel Have Been Notified of Revision to G-2.Const Engineering Procedures Require Requesting Design Approval Before Bending Embedded Rebar
ML19269B9277 December 1978Deficiency Rept 3 on HPCS Motor Control Center Wiring Discrepancies(Nrc HNP-A-013)
ML19276F6417 March 1979Final Rept,Ncr HNP-A-021,on Wiring Discrepancies in High Pressure Core Spray Diesel Generator Control Switchgear. Lists Discrepancies Found.Problems Have Been Identified & Will Be Corrected
ML19289C89916 November 1978Final Rept of Deficiency:Shaft Key & Spline Adapter of Basic in-flow Valves May Vibrate Loose & Fall Away,Leaving Valve Inoperable.Corrective Action:Stainless Steel Spacer to Be Inserted Against End of Valve Stem
ML19290B73215 November 1979Final Deficiency Rept Re Design Deficiency of T-head Section of Anchor/Darling Gate Valves.Company Has Implemented Results of Evaluation of T-head Section for Svc Condition, Into Internal Design Std
ML19291C25218 January 1980Final Deficiency Rept Re Inadequate Matl Traceability on Bergen-Paterson Component Support Attachments.Caused by Vendor Failure to Specify Heat Traceability Requirements on Detailed Drawings.Vendor Will Replace Attachments
ML19295A61819 September 1980Part 21 Rept Re Potential Defect in Component of Dsrv Standby Diesel Generator Concerning Link Rod Assembly Which Could Result in Engine Failure.Defect Limited to Models Dsrv 12,DSRV 16 & Dsrv 20 Built Before Feb 1980
ML19296B77314 February 1980Final Deficiency Rept Re Unacceptable QA Documentation for Glazer Steel Matl.Util QA Survey Determined QA Program Unacceptable.Until Acceptable QA Level Achieved,Only Steel Shipped Direct from Mill Will Be Accepted
ML19296C66415 February 1980Final Deficiency Rept Re Radiographic Exam of Hartsville Drywell Vent Structure & Phipps Bend Reactor Pressure Vessel Pedestal Weld Buildup.Exam Improperly Performed & Evaluated. Partially Caused by Inadequate Exposure of FilmEarthquake
ML19305A80713 March 1980Interim Deficiency Rept Re Weld Deficiencies in Reactor Pressure Vessel Shield Wall.Of 25 Welds inspected,17 Were Found to Be of Unacceptable Quality.Backing Bar Will Be Stripped from First Two Shells of Wall
ML19305C37919 March 1980Third Interim Deficiency Rept Re Deficient Welds Between Containment Anchor Bolt Chair & Both Containment Shell & Base Plate.Cause Unstated.Work Halted on Containment Anchor Bolt Chair for Units 1 & 2.All Welders to Attend Training
ML19305D6953 April 1980Suppl to Final Deficiency Rept Re Unacceptable QA Documentation for Glazer Steel Matl.All Questionable Matl Has Been Tested.Slightly Excessive Sulfur Content Is Caused by Chemical Differences & Not QA Sys Defects
ML19305D93831 March 1980Revised Corrective Actions to 800213 Final Deficiency Rept. Buttered Edges on Reactor Pressure Vessel Pedestal Examined & Repaired.Vendor Film Quality Sufficient to Produce Repair OverlaysWeld Overlay
ML19309A83627 March 1980Interim Deficiency Rept Re Potential Overstress Condition in Letdown Cooler Supports.Nozzle Loads Will Be Analyzed for Effects on Support Structure to Determine If Mods Are Required to Cooler Support Sys
ML19309A8433 March 1980Forwards Addl Info to Part 21 Rept Re Potentially Overstressed Supports on Reactor Coolant Letdown Coolers at Facilities Under Const by B&W
ML19309F11614 April 1980First Interim Deficiency Rept Re Cracks in Reactor Pressure Vessel Shield Wall.Three Base Metal Cracks Were Found in Shield Wall Inner Shell Plates.Cause to Be Determined Pending Results of Singleton Analysis
ML19309F2437 April 1980Part 21 Rept Re Insp of Generator Control Panels for Emergency Diesel Generators.Results Determined Defects Could Degrade Emergency Diesel Unit to Unsafe Performance. Corrective Action Includes in-depth Insps & Training
ML19309F70324 April 1980First Interim Deficiency Rept Re Wiring in HPCS Metal Clad Switchgear.Ge Has Been Notified of Wiring Diagram & Labeling Discrepancies,Missing Wires & Billing Problems.Phipps Bend Mgt Investigating Discrepancies