Letter Sequence Approval |
---|
|
|
MONTHYEARML12242A5532012-08-27027 August 2012 End of Cycle (EOC) 26 Refueling Outage Steam Generator Inservice Inspection Report Project stage: Request ML13109A4532013-04-15015 April 2013 Unit 3 End of Cycle (EOC) 26 Refueling Outage Request for Additional Information (RAI) Response to 3EOC26 Steam Generator Inspection Project stage: Request ML13151A2522013-06-0303 June 2013 Review of the Steam Generator Tube Inspection Report for the Spring 2012 Refueling Outage Project stage: Approval 2013-04-15
[Table View] |
|
---|
Category:Letter
MONTHYEARML24255A3322024-10-16016 October 2024 SLRA - Revised SE Letter ML24297A6172024-10-11011 October 2024 PCA Letter to NRC Oconee Hurricane Helene ML24269A0912024-10-0909 October 2024 Request for Withholding Information from Public Disclosure IR 05000269/20243012024-09-23023 September 2024 NRC Operator License Examination Report 05000269/2024301, 05000270/2024301, and 05000287/2024301 ML24145A1782024-08-26026 August 2024 Issuance of Amendment Nos. 430, 432, and 431, to TS 5.5.2, Containment Leakage Rate Testing Program for a one-time Extension of the Type a Leak Rate Test Frequency IR 05000269/20240052024-08-26026 August 2024 Updated Inspection Plan for Oconee Nuclear Station, Units 1, 2 and 3 (Report 05000269/2024005, 05000270/2024005, and 05000287-2024005) ML24220A1092024-08-0808 August 2024 – Operator Licensing Examination Approval 05000269/2024301, 05000270/2024301, and 05000287/2024301 05000287/LER-2024-001, Procedure Deficiency Results in Inadvertent Automatic Feedwater Isolation and Automatic Emergency Feedwater Actuation2024-08-0202 August 2024 Procedure Deficiency Results in Inadvertent Automatic Feedwater Isolation and Automatic Emergency Feedwater Actuation IR 05000269/20240102024-08-0101 August 2024 Focused Engineering Inspection - Age-Related Degradation Report 05000269/2024010 and 05000270/2024010 and 05000287/2024010 IR 05000269/20240022024-07-25025 July 2024 Integrated Inspection Report 05000269/2024002 and 05000270/2024002 and 05000287/2024002 ML24192A1312024-07-15015 July 2024 Licensed Operator Positive Fitness-For-Duty Test ML24183A0972024-07-12012 July 2024 ISFSI; Catawba 1, 2 & ISFSI; McGuire 1, 2 & ISFSI; Oconee 1, 2, 3 & ISFSI; Shearon Harris 1; H. B. Robinson 2 & ISFSI; and Radioactive Package Shipping Under 10 CFR 71 (71-266 & 71-345) – Review of QA Program Changes EPID L-2024-LLQ-0002 ML24183A2352024-06-29029 June 2024 Update 3 to Interim Report Regarding a Potential Defect with Schneider Electric Medium Voltage Vr Type Circuit Breaker Part Number V5D4133Y000 ML24179A1102024-06-27027 June 2024 Submittal of Updated Final Safety Analysis Report Revision 30, Technical Specifications Bases Revisions, Selected Licensee Commitment Revisions, 10 CFR 50.59 Evaluation Summary Report, and 10 CFR 54.37 Update, and Notification ML24141A0482024-05-17017 May 2024 EN 56958_1 Ametek Solidstate Controls, Inc IR 05000269/20240012024-05-0303 May 2024 Integrated Inspection Report 05000269/2024001, 05000270/2024001 and 05000287/2024001 IR 05000269/20244022024-04-24024 April 2024 Security Baseline Inspection Report 05000269/2024402 and 05000270/2024402 and 05000287/2024402 ML24108A0792024-04-16016 April 2024 EN 57079 Paragon Energy Solutions Email Forwarding Part 21 Interim Report Re Potential Defect with Schneider Electric Medium Voltage Vr Type Circuit Breaker Part Number V5D4133Y000 IR 05000269/20244012024-03-28028 March 2024 – Security Baseline Inspection Report 05000269-2024401 and 05000270-2024401 and 05000287-2024401 ML24088A3052024-03-25025 March 2024 Fws to NRC, Agreement with Nlaa Determination for Tricolored Bat for Oconee Lr IR 05000269/20230062024-02-28028 February 2024 Annual Assessment Letter for Oconee Nuclear Station Units 1, 2 and 3 - (NRC Inspection Report 05000269/2023006, 05000270/2023006, and 05000287/2023006) ML24045A3062024-02-16016 February 2024 Ltr. to Michell Hicks, Principal Chief Eastern Band of Cherokee Re Oconee Nuclear Station Units 1,2, and 3 Section 106 ML24045A2962024-02-16016 February 2024 Ltr. to David Hill Principal Chief Muscogee Creek Nation Re Oconee Nuclear Station Units 1, 2, and 3 Section 106 ML24045A2972024-02-16016 February 2024 Ltr. to Dexter Sharp Chief Piedmont American Indian Assoc Re Oconee Nuclear Station Units 1, 2, and 3 Section 106 ML24045A3012024-02-16016 February 2024 Ltr. to Harold Hatcher Chief the Waccamaw Indian People Re Oconee Nuclear Station Units 1, 2, and 3 Section 106 ML24045A3052024-02-16016 February 2024 Ltr. to Louis Chavis Chief Beaver Creek Indians Re Oconee Nuclear Station Units 1, 2, and 3 Section 106 ML24045A3042024-02-16016 February 2024 Ltr. to Lisa M. Collins Chief the Wassamasaw Tribe of Varnertown Indians Re Oconee Nuclear Station Units 1, 2, and 3 Section 106 ML24045A3022024-02-16016 February 2024 Ltr. to Joe Bunch United Keetoowah Band of Cherokee Indians in Ok Re Oconee Nuclear Station Units 1, 2, and 3 Section 106 ML24045A3032024-02-16016 February 2024 Ltr. to John Creel Chief Edisto Natchez-Kusso Tribe of Sc Re Oconee Nuclear Station Units 1, 2, and 3 Section 106 ML24030A0052024-02-16016 February 2024 Ltr. to Brian Harris, Chief, Catawba Indian Nation; Re., Oconee Nuclear Station Units 1, 2, and 3 Section 106 ML24045A2952024-02-16016 February 2024 Ltr. to Chuck Hoskin, Jr, Principal Chief Cherokee Nation Re Oconee Nuclear Station Units 1, 2, and 3 Section 106 ML24045A2942024-02-16016 February 2024 Ltr. to Carolyn Chavis Bolton Chief Pee Dee Indian Nation of Upper Sc Re Oconee Nuclear Station Units 1, 2, and 3 Section 106 ML24045A2992024-02-16016 February 2024 Ltr. to Eric Pratt Chief the Santee Indian Organization Re Oconee Nuclear Station Units 1, 2, and 3 Section 106 ML24045A3082024-02-16016 February 2024 Ltr. to Ralph Oxendine Chief Sumter Tribe of Cheraw Indians Re Oconee Nuclear Station Units 1, 2, and 3 Section 106 ML24045A3072024-02-16016 February 2024 Ltr. to Pete Parr Chief Pee Dee Indian Tribe Re Oconee Nuclear Station Units 1, 2, and 3 Section 106 ML24011A1482024-02-13013 February 2024 Letter to Steven M. Snider-Oconee Nuclear Sta, Unites 1,2 & 3 Notice of Avail of the Draft Site-Specific Supp. 2, 2nd Renewal to the Generic EIS for Lic. Renew of Nuclear Plants ML24011A1532024-02-13013 February 2024 Letter to Tracy Watson EPA-Oconee Nuclear Sta, Unites 1, 2 & 3 Notice of Avail of the Draft Site-Specific Supp. 2, 2nd Renewal to the Generic EIS for Lic. Renew of Nuclear Plants IR 05000269/20230042024-02-13013 February 2024 Integrated Inspection Report 05000269/2023004, 05000270/2023004, and 05000287/2023004; and Inspection Report 07200040/2023001 ML24019A1442024-02-13013 February 2024 Letter to Reid Nelson, Executive Director, Achp; Re Oconee Nuclear Station Units 1, 2, and 3 Section 106 ML24030A5212024-02-13013 February 2024 Letter to Elizabeth Johnson, Director, SHPO; Re Oconee Nuclear Stations Units 1, 2, and 3 Section 106 ML23304A1422024-02-0101 February 2024 Issuance of Environmental Scoping Summary Report Associated with the U.S. Nuclear Regulatory Commission Staffs Review of the Oconee Nuclear Station, Units 1, 2, & 3, Subsequent License Renewal Application ML24005A2492024-01-24024 January 2024 Exemption from Select Requirements of 10 CFR Part 73 (Security Notifications, Reports, and Recordkeeping and Suspicious Activity Reporting) ML23331A7982023-12-14014 December 2023 Review of the Fall 2022 Steam Generator Tube Inspection Report (01R32) ML23262A9672023-12-13013 December 2023 Alternative to Use RR-22-0174, Risk-Informed Categorization and Treatment for Repair/Replacement Activities in Class 2 and 3 Systems Section XI, Division 1 ML23317A3462023-11-14014 November 2023 Duke Fleet - Correction Letter to License Amendment Nos. 312 & 340 Issuance of Amendments Regarding the Adoption of Technical Specifications Task Force Traveler TSTF-554, Revision 1 IR 05000269/20230032023-11-14014 November 2023 Integrated Inspection Report 05000269/2023003, 05000270/2023003, and 05000287/2023003; and IR 07200040/2023001; and Exercise of Enforcement Discretion ML23219A1402023-10-10010 October 2023 Audit Report Proposed Alternative to Use ASME Code Case N-752, Risk Informed Categorization and Treatment for Repair/Replacement Activities in Class 2 and 3 Systems XI, Division 1 ML23269A1102023-10-0606 October 2023 Letter to Steven Snider-Revised Schedule for the Environmental Review of the Oconee Nuclear Station, Unit 1, 2, and 3, Subsequent License Renewal Application ML23256A0882023-09-25025 September 2023 Issuance of Alternative to Steam Generator Welds ML23195A0782023-08-29029 August 2023 Issuance of Amendments Regarding the Adoption of Technical Specifications Task Force Traveler TSTF-554, Revision 1 2024-09-23
[Table view] |
Text
UNITED NUCLEAR REGULATORY WASHINGTON, D.C. 20555'()001 June 3, 2013 Mr. Scott Batson Site Vice President Oconee Nuclear Station Duke Energy Carolinas, LLC 7800 Rochester Highway Seneca, SC 29672-0752 OCONEE NUCLEAR STATION, UNIT 3, REVIEW OF THE STEAM GENERATOR TUBE INSPECTION REPORT FOR THE SPRING 2012 REFUELING OUTAGE (TAC NO. ME9449)
Dear Mr. Batson:
By letter dated August 27.2012 (Agencywide Documents Access and Management Systems (ADAMS) Accession No. ML 12242A553), as supplemented by letter dated April 15, 2013 (ADAMS Accession No. ML 13109A453).
Duke Energy Carolinas, LLC., the licensee, submitted information to the U.S. Nuclear Regulatory Commission (NRC) summarizing the results of the 2012 steam generator tube inspections at Oconee Nuclear Station, Unit 3 (ONS3). In addition to this report, the NRC staff summarized a conference call about the 2012 steam generator tube inspections at ONS3 in a letter to the licensee dated June 28,2012 (ADAMS Accession No. ML 12178A206).
The NRC staff has completed its review of the report and concludes that the licensee provided the information required by the ONS3 Technical Specifications.
No additional follow up is required at this time. The NRC staff's review is enclosed.
If you have any questions, please call me at 301-415-2901.
Sincerely, hn P. Boska, Senior Project Manager lant Licensing Branch 11-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-287
Enclosure:
As stated cc w/encl: Distribution via Listserv OCONEE NUCLEAR STATION, UNIT 3
SUMMARY
OF THE NRC STAFF'S REVIEW OF THE STEAM GENERATOR TUBE INSERVICE INSPECTION REPORT FOR THE 2012 REFUELING OUTAGE DOCKET NO. 50-287 By letter dated August 27,2012 (Agencywide Documents Access and Management Systems (ADAMS) Accession No. ML 12242A553), as supplemented by letter dated April 15, 2013 (ADAMS Accession No. ML 13109A453), Duke Energy Carolinas, LLC., the licensee, submitted information to the U.S. Nuclear Regulatory Commission (NRC) summarizing the results of the 2012 steam generator tube inspections at Oconee Nuclear Station, Unit 3 (ONS3). In addition to this report, the NRC staff summarized a conference call about the 2012 steam generator tube inspections at ONS3 in a letter to the licensee dated June 28, 2012 (ADAMS Accession No. ML 12178A206).
ONS3 is a two-loop pressurized-water reactor with replacement once-through steam generators (ROTSGs) manufactured by Babcock & Wilcox (B&W), Canada. The ONS3 ROTSGs were installed during the fall 2004 refueling outage. The ROTSGs contain 15,631 thermally treated Alloy 690 tubes that have been hydraulically expanded into the tubesheets to a depth of 13 inches. There are 15 Type 410 stainless steel tube support plates (TSP) of trifoil broach design; however, there are some round drilled openings at the 14th TSP. The inspection performed in spring 2012, was the fifth inservice inspection of the ROTSGs. The first inservice inspection of the ROTSGs at ONS3 (spring 2006) revealed widespread wear degradation of the tubing at TSP locations.
Oconee, Units 1 and 2, have also experienced this widespread tube wear degradation at TSP locations.
During the 2012 outage, the licensee detected wear attributed to tube-to-tube contact. The wear is located in tubes with the highest compression within the ROTSGs. All but one of these wear indications is traceable back to the first inspections performed after SG replacement.
The licensee stated that the cause of the tube-to-tube wear is believed to be lateral deflection of the tubes during heat-up when the shell is cooler than the tubes. As a result of the 2012 inspections, zero tubes were plugged in ROTSG 3A and two tubes were stabilized and plugged in ROTSG 3B. Two foreign objects were found in ROTSG 3A, one on the 11 th TSP and the other on the lower tubesheet.
The object on the lower tubesheet was removed and the object on the 11 th TSP was evaluated and found acceptable to be left in the ROTSG. Based on a review of the information provided, the NRC staff concludes that the licensee provided the information required by their technical specifications.
In addition, the NRC staff concludes that there are no technical issues that warrant follow-up action at this time since the inspections appear to be consistent with the objective of detecting potential tube degradation and the inspection results appear to be consistent with industry operating experience at similarly designed and operated units. Enclosure Mr. Scott Batson June 3,2013 Site Vice President Oconee Nuclear Station Duke Energy Carolinas, LLC 7800 Rochester Highway Seneca, SC 29672-0752 OCONEE NUCLEAR STATION, UNIT 3, REVIEW OF THE STEAM GENERATOR TUBE INSPECTION REPORT FOR THE SPRING 2012 REFUELING OUTAGE (TAC NO. ME9449)
Dear Mr. Batson:
By letter dated August 27,2012 (Agencywide Documents Access and Management Systems (ADAMS) Accession No. ML 12242A553), as supplemented by letter dated April 15, 2013 (ADAMS Accession No. ML 131 09A453) , Duke Energy Carolinas, LLC., the licensee, submitted information to the U.S. Nuclear Regulatory Commission (NRC) summarizing the results of the 2012 steam generator tube inspections at Oconee Nuclear Station, Unit 3 (ONS3). In addition to this report, the NRC staff summarized a conference call about the 2012 steam generator tube inspections at ONS3 in a letter to the licensee dated June 28,2012 (ADAMS Accession No. ML 12178A206).
The NRC staff has completed its review of the report and concludes that the licensee provided the information required by the ONS3 Technical Specifications.
No additional follow up is required at this time. The NRC staffs review is enclosed.
If you have any questions, please call me at 301-415-2901.
Sincerely, IRA! John P. Boska, Senior Project Manager Plant Licensing Branch 11-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-287
Enclosure:
As stated cc w/encl: Distribution via Listserv DISTRIBUTION:
PUBLIC LPLlI-1 R/F RidsAcrsAcnw_MailCTR Resource RidsNrrDorlDpr Resource RidsNrrDorlLpL2-1 Resource RidsNrrLASFigueroa Resource RidsNrrPMOconee Resource RidsOgcMailCenter Resource RidsRgn2MailCenter Resource RidsNrrDeEsgb Resource KKarwoski, NRR AJohnson, NRR ADAMS Accession No. ML 13151A252
"'See memo dated 5/21/13 OFFICE NRRlLPL2-1/PM NRRlLPL2-1/LA NRR/ESGB/BC*
NAME JBoska SFigueroa GKulesa RPascarelli DATE 06/03/13 06/03/13 05/21/13 06/03113 OFFICIAL RECORD COPY