Category:Memoranda
MONTHYEARML23044A3662023-02-15015 February 2023 Calendar Year 2022 Reactor Oversight Process Baseline Inspection Program Completion - Region III ML22034A3932022-02-16016 February 2022 Calendar Year 2021 Security Baseline Completion Memo ML21277A2472021-11-0505 November 2021 Notification of Significant Licensing Action - Proposed Issuance of Order Approving the Transfer of Licenses for Which a Hearing Has Been Requested - Exelon Generation Company, LLC; Et. Al ML20150A2862020-11-23023 November 2020 Memo to File: Environmental Assessment and Finding of No Significant Impact and NRC Financial Analysis for Exelon Generation Co., LLC Decommissioning Funding Plan Submitted in Accordance with 10 CFR 72.30(b) and (C) for LaSalle ISFSI ML20239A8322020-08-25025 August 2020 Summary of the August 4, 2020 Public Webinar to Discuss the NRC 2019 End-of-Cycle Plant Performance Assessment of LaSalle County Station, Units 1 and 2 ML17142A2382017-05-25025 May 2017 OEDO-17-00280 - Briefing Package for Drop-In Visit on June 9, 2017, by Senior Management of Exelon Generation Company, LLC with Chairman Svinicki, Commissioner Baran, and Commissioner Burns ML17037B8502017-02-0606 February 2017 08/21/1975 Notice of Meeting with Architect Engineers of Mark II Owners to Discuss Load Combinations and Analytical Techniques for Determining Stresses in Mechanical Components and Structures of Mark II Containments ML16154A0822016-06-0303 June 2016 Advisory Committee on Reactor Safeguards Review of the Lasalle County Station, Units 1 and 2, License Renewal Application Transmittal of the Final Safety Evaluation Report ML16088A2052016-03-28028 March 2016 Enclosure 1 - (72.30 DFP Reviews to Be Completed 2015) - Memo T Bowers from s Ruffin, Technial Assistance Requests - Review 2015 Tri-Annual Decommissioning Funding Plans for Multiple Independent Spent Fuel Storage Installations ML16088A2042016-03-28028 March 2016 Memo T Bowers from s Ruffin, Technical Assistance Requests - Review 2015 Tri-Annual Decommissioning Funding Plans for Multiple Independent Spent Fuel Storage Installations W/ Encl 2 (Template) ML16075A3292016-03-16016 March 2016 OEDO-16-00165 - Briefing Package for Drop-In Visit on March 23, 2016, by Senior Management of Exelon Generation Company, LLC with the NRC Executive Director for Operations ML16049A4232016-03-0202 March 2016 Advisory Committee on Reactor Safeguards Review of the LaSalle County Station, Units 1 and 2, License Renewal Application -Transmittal of Safety Evaluation Report with Open Items ML16021A3252016-01-29029 January 2016 Summary of Teleconference Held on January 21, 2016, Between the NRC and Exelon Generation Co., LLC, Concerning RAI 4.2.10-1 Response ML13309A0802013-12-11011 December 2013 Memorandum to File: Transcript for 10 CFR 2.206 Petition from Beyond Nuclear (Et Al) Regarding General Electric Mark I and Mark II Boiling-Water Reactors ML13190A3522013-07-10010 July 2013 Notice of Forthcoming Teleconference with Exelon Generation Company, LLC ML13097A0022013-04-17017 April 2013 Forthcoming Meeting with Exelon Generation Company, LLC Regarding Deferred Implementation of Proposed Extended Power Uprate License Amendment Request for LaSalle County Station, Units 1 and 2 ML12320A4222013-01-0909 January 2013 Request for Additional Information Related to License Amendment to Technical Specification 3.7.3 Ultimate Heat Sink (ME9076 and ME9077) ML12348A6962012-12-17017 December 2012 1/3/2013 - Notice of Forthcoming Meeting with Exelon Generation Company, LLC, to Discuss Requests for Additional Information Regarding Exelon Physical Security Plans ML12167A1292012-06-18018 June 2012 6/28/2012 Forthcoming Pre-Application Meeting with Exelon Generating Company, LLC, to Discuss Licensing Amendment Request for LaSalle County Station Unit 1 and 2 Ultimate Heat Sink ML12137A1792012-05-17017 May 2012 Forthcoming Pre-submittal Public Meeting with Exelon Generation Company, LLC Regarding LaSalle Extended Power Uprate Replacement Steam Dryer ML1208602902012-03-26026 March 2012 Notice of Forthcoming Public Meeting with Exelon Generation to Discuss Future Fleet Submittal Regarding Licensed Operator Eligibility Requirements ML1206807332012-03-20020 March 2012 Forthcoming Public Meeting with Exelon Generation Company, LLC Regarding Proposed License Amendment Request to Install Power Range Neutron Monitor ML1129114092011-10-18018 October 2011 Notice of Meeting with Exelon and NEI, to Discuss Application of Nuclear Energy Institute Pilot for Pre-Submittal Meetings to LaSalle Nuclear Power Station Extended Power Uprate Submittal ML1114409852011-05-26026 May 2011 Notice of Meeting with Exelon to Discuss Proposed License Amendment Request Related to the Installation of a Power Range Neutron Monitoring System for LaSalle Units 1 and 2 ML1028003592010-10-0707 October 2010 Notice of Public Meeting with Exelon Generation Company, LLC, Regarding LaSalle Netco Insert Request ML1022501922010-08-12012 August 2010 Memo C Lipa, Response to Region-III Technical Assistance Request - LaSalle Station and Byron Station Independent Spent Fuel Storage Installation (ISFSI) Pad Seismic Design REGION-III TAR ML101680320 Dated 6-4-2010 ML1011904862010-05-0303 May 2010 Notice of Meeting with Exelon, LaSalle, Units 1 and 2, to Discuss Response to Request for Additional Information License Amendment Request Regarding the Use of Neutron Absorbing Inserts in Spent Fuel Pool Storage Racks ML1002005172010-01-20020 January 2010 Memo to C. A. Lipa Revision to Response to Region III Technical Assistance Request- LaSalle Station Independent Spent Fuel Storage Installation (ISFSI) Pad- Seismic Design LaSalle Station Region III Technical Assistance Request (TAR) Dated ML0930205882009-11-16016 November 2009 Staff Review of LaSalle County Generating Station ISFSI Physical Security Plan and ASM Incorporation ML0926801972009-09-29029 September 2009 Notice of Pre-application Meeting to Discuss Egc'S Plants to Submit Power Uprate Requests for Various Units in Its Reactor Fleet ML0914901422009-06-0909 June 2009 Notice of Meeting with Exelon Generation Company on Licensing Practices and Processes ML0915903582009-06-0808 June 2009 Notice of Meetng with Exelon Generation Company to Discuss the Recapture License Amendment Request ML0906305362009-03-0404 March 2009 Corrected Notice of Meeting with Exelon to Discuss Request That Allow Use of NETCO-SNAPIN Inserts in the Lasalle County Station, Unit 2, Spent Fuel Storage Rack Cells as Neutron Absorbing Hardware ML0905705582009-03-0404 March 2009 Notice of Meeting with Exelon to Discuss Request That Allow Use of NETCO-SNAP-IN Inserts in LaSalle County Station, Unit 2, Spent Fuel Storage Rack Cells as Neutron Absorbing Hardware ML0810800102008-04-16016 April 2008 Summary of Public Meeting with NRC and Exelon Generation Company LaSalle Performance Assessment, with Presentation Slides ML0810600322008-04-15015 April 2008 Notice of Revised Meeting with Exelon Generation Company, LLC to Discuss Licensing Activities for Braidwood, Byron, Clinton, Dresden, LaSalle, Limerick, Oyster Creek, Peach Bottom, Quad Cities, and Three Mile Island ML0808605822008-04-0808 April 2008 Notice of Meeting with Exelon Generation Company, LLC (Exelon), to Discuss Licensing Activities ML0807400842008-03-14014 March 2008 Draft Regulatory Guide for Comment ML0700900372007-01-0909 January 2007 Extension of TS Completion Times, Associated with the Residual Heat Removal Service Water System, Diesel Generator Cooling Water System, and the Core Standby Cooling System ML0626904432006-09-25025 September 2006 Memo 09/25/06 LaSalle: Re Input to DRP IR 06-005 ML0607305732006-03-13013 March 2006 Memo 03/13/06 LaSalle DRS Input to DRP IR 06-003 Dej ML0606702252006-03-0808 March 2006 Meeting with Exelon to Discuss LaSalle Amendment Request Related to the Extension of Completion Times for the Core Standby Cooling System Maintenance ML0511604182005-04-21021 April 2005 4/21/05, Braidwood and Byron Stations, Units 1 and 2 - Summary of April 12, 2005, Telephone Conference Regarding the Emergency Plan for the Above Facilities (TAC Nos. MC6669 Thru MC6684) ML0417400862004-06-21021 June 2004 All Region III Facility Training Managers Revised NRC Form 398 - Personal Qualification Statement Licensee ML0323801232003-08-25025 August 2003 Results of the Lasalle Nuclear Power Station, Units 1 and 2 SDP Phase 2 Notebook Benchmarking Visit ML0324005922003-05-24024 May 2003 May 10-11, 2000, Summary of NRC Senior Management Meeting to Review Performance of Operating Nuclear Power Plants and Materials Facilities Licensed by Nrc. Partially Withheld ML0306400152003-04-28028 April 2003 TIA, Evaluation of LaSalle Water Hammer Analysis, Revision 1 ML0226002922002-09-17017 September 2002 Memorandum Regarding Report on the Status of Open TIAs Assigned to NRR ML0210505942002-04-17017 April 2002 Notice of Meeting with Exelon Generation Company to Discuss Aspects of Security Orders ML0212006172002-03-18018 March 2002 Enclosures to 03/18/2002 Meeting Summary 2023-02-15
[Table view] |
Text
January 20, 2010 MEMORANDUM TO: Christine A. Lipa, Branch Chief Division of Nuclear Materials Safety, Region III FROM: Eric Benner, Branch Chief /RA/
Licensing Branch Division of Spent Fuel Storage and Transportation
SUBJECT:
REVISION TO RESPONSE TO REGION III TECHNICAL ASSISTANCE REQUEST - LASALLE STATION INDEPENDENT SPENT FUEL STORAGE INSTALLATION (ISFSI) PAD -
SEISMIC DESIGN LASALLE STATION REGION III TECHNICAL ASSISTANCE REQUEST (TAR) DATED 10-20-2009 On October 16, 2009, NRC Region III transmitted a Technical Assistance Request (TAR) to the NMSS Division of Spent Fuel Storage and Transportation (DSFST), concerning the independent spent fuel storage installation (ISFSI) Pad constructed at the LaSalle Station (LS). In your request, you asked that DSFST review related background documents as shown in the TAR, performed by the licensee (Exelon Nuclear) and their contractor(s) HOLTEC and others that address the seismic design and analysis of the ISFSI Pad. These potential problems were raised as part of an Inspection currently under review by Region III; however, the scope of our review was limited to the licensees evaluations in the referenced documents (Package ADAMS accession number ML092881250) and determining the appropriateness and applicability of the use of nomograms presented in the NUREG/CR-6865 for analysis and design of the ISFSI Pad, in order to determine whether the licensees meet regulatory requirements.
DSFST has completed its review of the licensees seismic analyses of the LS ISFSI Pad and provides the enclosed assessment in response to your assistance request. Based on our review of the methodology, approach, results and conclusions documented by the licensee and its consultants, the SFST staff concludes that the seismic design of the LS ISFSI foundation has not met the requirements of the CoC and that the structural performance of the foundation has not met the applicable acceptance criteria during a safe-shutdown earthquake. Please note that our review, summary and conclusions are pertinent to LaSalle Station ISFSI pad only.
Enclosed, per your request, is a revised version of the response to the TAR delivered to you January 8, 2010, correcting typographical errors.
CONTACT: Bob Tripathi, DSFST 301-492-3281 Docket No: 050-373/374; 072-00070.
Enclosure:
Revised Response to Region III TAR - LS ISFSI Pad seismic analysis
January 20, 2010 MEMORANDUM TO: Christine A. Lipa, Branch Chief Division of Nuclear Materials Safety, Region III FROM: Eric Benner, Branch Chief /RA/
Licensing Branch Division of Spent Fuel Storage and Transportation
SUBJECT:
REVISION TO RESPONSE TO REGION III TECHNICAL ASSISTANCE REQUEST - LASALLE STATION INDEPENDENT SPENT FUEL STORAGE INSTALLATION (ISFSI) PAD - SEISMIC DESIGN LASALLE STATION REGION III TECHNICAL ASSISTANCE REQUEST (TAR)
DATED 10-20-2009 On October 16, 2009, NRC Region III transmitted a Technical Assistance Request (TAR) to the NMSS Division of Spent Fuel Storage and Transportation (DSFST), concerning the independent spent fuel storage installation (ISFSI) Pad constructed at the LaSalle Station (LS). In your request, you asked that DSFST review related background documents as shown in the TAR, performed by the licensee (Exelon Nuclear) and their contractor(s) HOLTEC and others that address the seismic design and analysis of the ISFSI Pad. These potential problems were raised as part of an Inspection currently under review by Region III; however, the scope of our review was limited to the licensees evaluations in the referenced documents (Package ADAMS accession number ML092881250) and determining the appropriateness and applicability of the use of nomograms presented in the NUREG/CR-6865 for analysis and design of the ISFSI Pad, in order to determine whether the licensees meet regulatory requirements.
DSFST has completed its review of the licensees seismic analyses of the LS ISFSI Pad and provides the enclosed assessment in response to your assistance request. Based on our review of the methodology, approach, results and conclusions documented by the licensee and its consultants, the SFST staff concludes that the seismic design of the LS ISFSI foundation has not met the requirements of the CoC and that the structural performance of the foundation has not met the applicable acceptance criteria during a safe-shutdown earthquake. Please note that our review, summary and conclusions are pertinent to LaSalle Station ISFSI pad only.
Enclosed, per your request, is a revised version of the response to the TAR delivered to you January 8, 2010, correcting typographical errors.
CONTACT: Bob Tripathi, DSFST 301-492-3281 Docket No: 050-373/374; 072-00070.
Enclosure:
Revised Response to Region III TAR - LS ISFSI Pad seismic analysis DISTRIBUTION:
SFST r/f BWhite, RLorson VOrdaz CLipa, RIII DHills, RIII VMeghani, RIII DSFST Ticket No: 201000003 G:\SFST\Tripathi\Cover Letter - Jan20 neew TAR Tripathi.doc ADAMS PACKAGE No.: ML100200515 OFC: SFST SFST SFST SFST SFST NAME: BTripathi CCook EBenner GBjorkman RLorson DATE: 1//20/10 1/08/10 1/20/10 1/08/10 1/08/10 C = COVER E = COVER & ENCLOSURE N = NO COPY OFFICIAL RECORD COPY