MONTHYEARML24295A3622024-10-21021 October 2024 Request for Additional Information Quality Assurance Program to Support License Transfer Request ML24289A1962024-10-10010 October 2024 Email Dated October 10, 2024 from Wallace Taylor Indicating His Intention to Refile ML24289A1952024-10-0909 October 2024 Follow-up Email Dated October 9, 2024 from the Office of the Secretary to Wallace Taylor Regarding the Filing Error ML24289A1932024-10-0808 October 2024 Email Dated October 9, 2024 from the Office of the Secretary to Wallace Taylor Regarding Filing Error ML24289A1942024-10-0808 October 2024 Email Dated October 8, 2024 from the Office of the Secretary to the Participants of the Palisades 50-255 & 72-007 LT-3 Proceeding Regarding Filing Error ML24277A3062024-10-0303 October 2024 Restart La Docs - 9-18-2024 Michigan SHPO Comments on Palisades Phase I Archaeological Survey ML24277A3042024-10-0303 October 2024 Restart La Docs - Sokaogon Chippewa Community Reply to NRC Status Update Re Palisades Restart ML24277A3032024-10-0303 October 2024 Restart La Docs - (External_Sender) Re Status Update - Palisades Request for Reauthorization of Power Operations ML24277A3082024-10-0303 October 2024 Restart La Docs - 10-2-2024 Michigan SHPO Comments Re Palisades Nuclear Plant Architectural Survey ML24277A3072024-10-0202 October 2024 Restart La Docs - (External_Sender) ER24-431 Palisades Nuclear Plant Subsequent License Renewal, Covert Township, Van Buren County (NRC) ML24270A2622024-09-26026 September 2024 Email to Petitioners and Licensee Representatives Transmitting Order of the Secretary Re Petition for Declaratory Order from Beyond Nuclear Et Al., for the Palisades Nuclear Plant ML24269A0162024-09-24024 September 2024 Email from Holtec Decommissioning International, LLC Re Reply to Beyond Nuclear Et Al.S Petition for Declaratory Order ML24277A3052024-09-18018 September 2024 Restart La Docs - (External_Sender) Sec. 106 Consultation - ER24-431, Palisades Phase I Archaeological Survey ML24262A0742024-09-18018 September 2024 Restart La Docs - FW Palisades Scoping Comment Period Ended ...E-mail Capture Platform Status ML24262A0732024-09-18018 September 2024 Restart La Docs - FW Palisades Scoping Comment Period Ended ...E-mail Capture Platform Status ML24291A2442024-09-18018 September 2024 Response to Questions from Alan Blind Regarding Public Meeting on August 1, 2024 ML24260A3552024-09-16016 September 2024 Restart La Docs - Palisades Reauthorization of Power Operations- Environmental Audit RCI Responses ML24260A3542024-09-12012 September 2024 Restart La Docs - (External_Sender) Re Palisades Reauthorization of Power Operations- Environmental Audit Draft RCIs ML24248A0572024-09-0404 September 2024 Restart La Docs - Draft Letter in Support of Draft RAIs and Draft Environmental Regulatory Audit Plan ML24248A2612024-09-0404 September 2024 Restart La Docs - Palisades Reauthorization of Power Operations- Environmental Audit Draft RCIs ML24248A2622024-09-0404 September 2024 Restart La Docs - FW Palisades Reauthorization of Power Operations- Environmental Audit Draft RCIs ML24248A0902024-08-28028 August 2024 Steam Generator Inspection Call ML24270A2712024-08-0707 August 2024 Public Comments for August 1, 2024, Public Outreach Meeting on Potential Palisades Nuclear Plant Restart ML24192A0012024-07-0606 July 2024 (E-Mail) Palisades Nuclear Plant - Plant - Draft Request for Additional Information: Palisades Operating TS License Amendment Request - June 6, 2024 ML24187A1332024-07-0505 July 2024 LTR-24-0069 Emailed Response Regarding Palisades Restart Project ML24192A1672024-06-28028 June 2024 Restart - NRC Request for Additional Information - EP ORO Coordination - June 28, 2024 ML24192A1472024-06-28028 June 2024 Email - Palisades Nuclear Plant - Draft Request for Additional Information: Palisades Administrative TS License Amendment Request - June 28, 2024 ML24248A0562024-06-27027 June 2024 Restart La Docs - Draft Letter in Support of Draft RAIs and Draft Environmental Regulatory Audit Plan ML24135A3542024-05-20020 May 2024 NRC Response to Jody Flynn of Michigan Regarding Statements Made About Holtec in the April 25, 2024 Peekskill Herald Article: Holtec Playing Fast and Loose with Taxpayers Money by Tina Volz-Bongar (Docket 50-255) ML24141A0862024-05-16016 May 2024 Notification of NRC Activities Regarding Palisades Restart ML24170A8812024-05-15015 May 2024 NRR E-mail Capture - Post Acceptance/Abeyance Process for the 10 CFR 2.206 Petition on Palisades Misuse of Decommissioning Trust Fund ML24032A2442024-02-0101 February 2024 OEDO-24-00011 - 10 CFR 2.206 Petition Holtec Misuse Decommissioning Fund- Email to Petitioner ML24005A1262024-01-0505 January 2024 Permanently Defueled Emergency Plan Implementation Notification ML23055A1532023-02-24024 February 2023 Request for Additional Information Related to the Post-Shutdown Decommissioning Activities Report ML22343A1902022-12-0909 December 2022 Acceptance Review: Palisades Proposed Exemption from 10 CFR 140.11 (a)(4) Primary and Secondary Liability Insurance ML22343A2282022-12-0909 December 2022 Acceptance Review: Palisades Proposed Exemption from 10 CFR 50.54(w)(1) - Onsite Property Damage Insurance ML22284A0502022-10-0707 October 2022 Acceptance Review: License Amendment Request to Revise License Condition to Eliminate Cyber Security Plan Requirements ML22227A0092022-08-12012 August 2022 Acceptance Review: License Amendment Request to Revise Emergency Plan and Emergency Action Level Scheme (L-2022-LLA-0099) ML22227A0082022-08-12012 August 2022 Acceptance Review: Exemption Request from 10CFR50.47(b), 10 CFR 50.47(c)(2), and 10 CFR Part 50, Appendix E, Section IV ML22179A0752022-06-28028 June 2022 E-mail from Entergy Dated June 28, 2022, Notification of Palisades and Big Rock Point License Transfer (EPIDs L-2022-LLM-0002 and L-2020-LLM-0003) ML22159A2672022-06-0202 June 2022 Answers to Your Questions on Palisades ML22159A2652022-05-0303 May 2022 Questions Asked at Palisades Plant Performance Public Meeting April 26, 2022 ML21328A0062021-11-18018 November 2021 NRR E-mail Capture - (External_Sender) State of Michigan Response - Palisades Nuclear Plant and Big Rock Point Plant - Application for Order Consenting to Transfers of Licenses and Conforming License Amendments ML22208A1052021-11-16016 November 2021 NRR E-mail Capture - (External_Sender) State of Michigan Response - Palisades - Preparation for Issuance of Final Environmental Assessment and Finding of No Significant Impact Holtec Exemption Request to Use Dtf ML21309A5152021-11-0505 November 2021 NRR E-mail Capture - Palisades Nuclear Plant - Preparation for Issuance of Final Environmental Assessment and Finding of No Significant Impact Holtec Exemption Request to Use Dtf ML21309A2982021-11-0505 November 2021 NRR E-mail Capture - Palisades Nuclear Plant and Big Rock Point Plant - Application for Order Consenting to Transfers of Licenses and Conforming License Amendments ML21209A9802021-07-28028 July 2021 NRR E-mail Capture - Palisades Nuclear Plant - Acceptance of Requested Licensing Action, Rescission of Interim Compensatory Measure from Order EA-02-026 ML21189A2462021-07-0606 July 2021 NRR E-mail Capture - Palisades Nuclear Plant - Acceptance of Requested Licensing Action, Proposed Partial Exemption from Record Retention Requirements ML21189A0432021-07-0606 July 2021 NRR E-mail Capture - Palisades Nuclear Plant - Acceptance of Requested Licensing Action, Permanently Defueled Technical Specifications ML21054A1822021-02-23023 February 2021 NRR E-mail Capture - Regarding Public Comment on Palisades Request for Relief RR 5-8 2024-09-04
[Table view] |
Text
From: Mahesh Chawla To: bdotson@entergy.com; llahti@entergy.com Date: 09/24/2007 10:52:58 AM
Subject:
2006 SG Tube Inspections By letters dated April 26, 2006 (ML061160510), April 11, 2007 (ML071090247),
and June 19, 2007 (ML071780216), Entergy Nuclear Operations, Inc. (the licensee)
submitted information pertaining to their 2006 steam generator (SG) tube
inspections at the Palisades Nuclear Plant. The U.S. Nuclear Regulatory
Commission (NRC) staff summarized three conference calls held with the
licensee, concerning the 2006 SG tube inspections, in a letter dated September
22, 2006 (ML062560069). In order to complete its review of the documents
listed above, the staff needs the following additional information:
- 1. You indicated that the location, orientation, and measured sizes of
service-induced indications were included in Tables 4A, 4B, and 4C. These
tables do not appear to contain all service-induced indications, since none of
the wear indications listed in Table 6 are included in these tables. Please
clarify. Please provide the sizes for the wear indications in Tables 4B and
4C (since presumably they were sized and are less than 40% throughwall).
- 2. In Table 3, you highlighted various degradation mechanisms for which you
inspected. Please clarify this table. In particular, discuss whether you
consider dents and dings greater than five volts susceptible to axial and
circumferential primary water stress corrosion cracking and outside diameter
stress corrosion cracking (ODSCC).
- 3. Please provide the scope and results of any secondary side inspections
(including foreign object search and retrieval) performed during
the 2006 outage.
- 4. Please clarify Table 6 and the discussion on in-situ pressure testing.
Table 6 does not appear to address the results of condition monitoring, but
the discussion on in-situ pressure testing does appear to address some of the
results of the condition monitoring assessment. With respect to condition
monitoring, please address the following:
- a. Please discuss whether a bladder was used at the location of the flaw
during the in-situ pressure testing.
- b. Please confirm that none of the structural integrity performance
criteria contained within the Technical Specifications were exceeded (e.g.,
factor of 1.2 on combined primary loads).
- c. Please confirm that you satisfied the accident-induced leakage
performance criterion and please provide the leak rate you calculated during
this assessment, making sure to include leakage from all sources (e.g.,
plugs).
- 5. Clarify the entries in Table 4A since several of the freespan
indications seem to be below the top of the tubesheet and some of the eggcrate
indications appear to be in the freespan.
- 6. Clarify the number of axial ODSCC indications in the freespan and eggcrate locations. Table 5 indicates two indications are at eggcrates and one indication is in the freespan; however, Table 6
only lists one indication at an eggcrate (R71C84) and two indications
in the freespan (R133C90 and R80C131).
CC: Allen Hiser; Andrew Johnson; Kenneth Karwoski
Mail Envelope Properties (46F7CF4A.823 : 2 : 35476)
Subject:
2006 SG Tube Inspections Creation Date 09/24/2007 10:52:58 AM From: Mahesh Chawla Created By: MLC@nrc.gov Recipients Action Date & Time entergy.com Transferred 09/24/2007 10:53:14 AM bdotson (bdotson@entergy.com) llahti (llahti@entergy.com)
nrc.gov OWGWPO04.HQGWDO01 Delivered 09/24/2007 10:53:06
AM ABJ1 CC (Andrew Johnson) Opened 09/24/2007 11:11:50
AM ALH1 CC (Allen Hiser) Opened 09/24/2007 11:09:53
AM KJK1 CC (Kenneth Karwoski) Opened 09/24/2007 11:16:31
AM Post Office Delivered Route entergy.com OWGWPO04.HQGWDO01 09/24/2007 10:53:06 AM nrc.gov
Files Size Date & Time MESSAGE 4023 09/24/2007 10:52:58 AM Options Auto Delete:
No Expiration Date:
None Notify Recipients:
Yes Priority:
Standard ReplyRequested:
No Return Notification:
None Concealed
Subject:
No Security:
Standard To Be Delivered: Immediate Status Tracking: Delivered & Opened