IR 05000289/2014406: Difference between revisions
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 2: | Line 2: | ||
| number = ML14234A149 | | number = ML14234A149 | ||
| issue date = 08/22/2014 | | issue date = 08/22/2014 | ||
| title = IR 050002892014406, | | title = IR 050002892014406, July 24, 2014, Three Mile Island Nuclear Station, Unit 1, NRC Material Control and Accounting Program | ||
| author name = Finney P W | | author name = Finney P W | ||
| author affiliation = NRC/RGN-I/DRP | | author affiliation = NRC/RGN-I/DRP | ||
Line 21: | Line 21: | ||
[[Issue date::August 22, 2014]] | [[Issue date::August 22, 2014]] | ||
Mr. | Mr. Michael Senior Vice President Exelon Generation Company, LLC President and Chief Nuclear Officer Exelon Nuclear 4300 Winfield Rd. | ||
Warrenville, IL | Warrenville, IL 60555 | ||
SUBJECT: | SUBJECT: THREE MILE ISLAND NUCLEAR STATION, UNIT 1 - U.S. NUCLEAR REGULATORY COMMISSION MATERIAL CONTROL AND ACCOUNTING PROGRAM INSPECTION REPORT NO. 05000289/2014406 | ||
==Dear Mr. Pacilio:== | ==Dear Mr. Pacilio:== | ||
Line 34: | Line 34: | ||
In accordance with Title 10 of the Code of Federal Regulations (10 CFR) Part 2.390, "Public Inspections, Exemptions, Requests for Withholding," of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC's Public Document Room or from the Publicly Available Records (PARS) component of the NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). However, the material enclosed herewith contains Security-Related information in accordance with 10 CFR 2.390(d)(1) and its disclosure to unauthorized individuals could present a security vulnerability. Therefore, the material in the enclosure will not be made available electronically for public inspection in the NRC Public Document Room or from the PARS component of NRC's ADAMS. | In accordance with Title 10 of the Code of Federal Regulations (10 CFR) Part 2.390, "Public Inspections, Exemptions, Requests for Withholding," of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC's Public Document Room or from the Publicly Available Records (PARS) component of the NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). However, the material enclosed herewith contains Security-Related information in accordance with 10 CFR 2.390(d)(1) and its disclosure to unauthorized individuals could present a security vulnerability. Therefore, the material in the enclosure will not be made available electronically for public inspection in the NRC Public Document Room or from the PARS component of NRC's ADAMS. | ||
Enclosure contains Sensitive Unclassified Non-Safeguards Information. When separated from enclosure, the transmittal document is decontrolled.If you choose to provide a response, and Security-Related Information is necessary to provide an acceptable response, please mark your entire response "Security-Related Information- | Enclosure contains Sensitive Unclassified Non-Safeguards Information. When separated from enclosure, the transmittal document is decontrolled. If you choose to provide a response, and Security-Related Information is necessary to provide an acceptable response, please mark your entire response "Security-Related Information- | ||
Withhold from public disclosure under 10 CFR 2.390" in accordance with 10 CFR 2.390(d)(1) | Withhold from public disclosure under 10 CFR 2.390" in accordance with 10 CFR 2.390(d)(1) | ||
and follow the instructions for withholding in 10 CFR 2.390(b)(1). In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response. | and follow the instructions for withholding in 10 CFR 2.390(b)(1). In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response. | ||
Line 44: | Line 44: | ||
===Enclosure:=== | ===Enclosure:=== | ||
NRC Inspection Report 05000289/2014406 | NRC Inspection Report 05000289/2014406 | ||
===w/Attachment:=== | ===w/Attachment:=== | ||
Supplemental Information (CONTAINS | Supplemental Information (CONTAINS (OUO-SRI)) cc w/encl; w/OUO-SRI: R. Campbell, Manager, Site Security Operations D. Allard, Director, PA DEP cc w/o encl; w/o OUO-SRI: Distribution via ListServ | ||
}} | }} |
Revision as of 20:48, 18 February 2018
ML14234A149 | |
Person / Time | |
---|---|
Site: | Three Mile Island |
Issue date: | 08/22/2014 |
From: | Finney P W Division Reactor Projects I |
To: | Pacilio M J Exelon Generation Co |
References | |
IR-2014-406 | |
Download: ML14234A149 (4) | |
Text
August 22, 2014
Mr. Michael Senior Vice President Exelon Generation Company, LLC President and Chief Nuclear Officer Exelon Nuclear 4300 Winfield Rd.
Warrenville, IL 60555
SUBJECT: THREE MILE ISLAND NUCLEAR STATION, UNIT 1 - U.S. NUCLEAR REGULATORY COMMISSION MATERIAL CONTROL AND ACCOUNTING PROGRAM INSPECTION REPORT NO. 05000289/2014406
Dear Mr. Pacilio:
On July 24, 2014, the U.S. Nuclear Regulatory Commission (NRC) completed a security inspection at your Three Mile Island Nuclear Station (TMI), Unit 1. The NRC inspectors discussed the results of this inspection with Mr. Randy Campbell, Manager, Site Security Operations, and other members of your staff. Inspectors documented the results of this inspection in the enclosed inspection report.
The inspectors did not identify any findings or violations with more than minor significance.
In accordance with Title 10 of the Code of Federal Regulations (10 CFR) Part 2.390, "Public Inspections, Exemptions, Requests for Withholding," of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC's Public Document Room or from the Publicly Available Records (PARS) component of the NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). However, the material enclosed herewith contains Security-Related information in accordance with 10 CFR 2.390(d)(1) and its disclosure to unauthorized individuals could present a security vulnerability. Therefore, the material in the enclosure will not be made available electronically for public inspection in the NRC Public Document Room or from the PARS component of NRC's ADAMS.
Enclosure contains Sensitive Unclassified Non-Safeguards Information. When separated from enclosure, the transmittal document is decontrolled. If you choose to provide a response, and Security-Related Information is necessary to provide an acceptable response, please mark your entire response "Security-Related Information-
Withhold from public disclosure under 10 CFR 2.390" in accordance with 10 CFR 2.390(d)(1)
and follow the instructions for withholding in 10 CFR 2.390(b)(1). In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response.
Sincerely,/RA/
Patrick W. Finney, Acting Chief Technical Support and Assessment Branch Division of Reactor Projects Docket No. 50-289 License No. DPR-50
Nonpublic
Enclosure:
NRC Inspection Report 05000289/2014406
w/Attachment:
Supplemental Information (CONTAINS (OUO-SRI)) cc w/encl; w/OUO-SRI: R. Campbell, Manager, Site Security Operations D. Allard, Director, PA DEP cc w/o encl; w/o OUO-SRI: Distribution via ListServ