ML15125A280: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
 
(14 intermediate revisions by the same user not shown)
Line 2: Line 2:
| number = ML15125A280
| number = ML15125A280
| issue date = 05/06/2015
| issue date = 05/06/2015
| title = Texas Engineering Experiment Station/Texas A&M University System - Request for Additional Information Regarding the Renewal of Facility Operating License No. R-83 for the Nuclear Science Center Triga Reactor (TAC ME1584)
| title = Texas Engineering Experiment Station/Texas A&M University System - Request for Additional Information Regarding the Renewal of Facility Operating License No. R-83 for the Nuclear Science Center Triga Reactor
| author name = Wertz G A
| author name = Wertz G
| author affiliation = NRC/NRR/DPR/PRTA
| author affiliation = NRC/NRR/DPR/PRTA
| addressee name = McDeavitt S M
| addressee name = Mcdeavitt S
| addressee affiliation = Texas A&M Univ
| addressee affiliation = Texas A&M Univ
| docket = 05000128
| docket = 05000128
| license number = R-083
| license number = R-083
| contact person = McDeavitt S M
| contact person = McDeavitt S
| case reference number = TAC ME1584
| case reference number = TAC ME1584
| document type = Letter, Request for Additional Information (RAI)
| document type = Letter, Request for Additional Information (RAI)
| page count = 8
| page count = 8
| project = TAC:ME1584
| project = TAC:ME1584
| stage = RAI
}}
}}


=Text=
=Text=
{{#Wiki_filter:   May 6, 2015  
{{#Wiki_filter:May 6, 2015 Dr. Sean McDeavitt, Director Nuclear Science Center Texas Engineering Experiment Station 1095 Nuclear Science Road MS 3575 College Station, TX 77843


Dr. Sean McDeavitt, Director Nuclear Science Center Texas Engineering Experiment Station 1095 Nuclear Science Road MS 3575 College Station, TX  77843
==SUBJECT:==
TEXAS ENGINEERING EXPERIMENT STATION/TEXAS A&M UNIVERSITY SYSTEM - REQUEST FOR ADDITIONAL INFORMATION REGARDING THE RENEWAL OF FACILITY OPERATING LICENSE NO. R-83 FOR THE NUCLEAR SCIENCE CENTER TRIGA REACTOR (TAC NO. ME1584)


SUBJECT:  TEXAS ENGINEERING EXPERIMENT STATION/TEXAS A&M UNIVERSITY SYSTEM - REQUEST FOR ADDITIONAL INFORMATION REGARDING THE RENEWAL OF FACILITY OPERATING LICENSE NO. R-83 FOR THE NUCLEAR SCIENCE CENTER TRIGA REACTOR (TAC NO. ME1584)
==Dear Dr. McDeavitt:==
Dear Dr. McDeavitt: The U.S. Nuclear Regulatory Commission (NRC) is continuing its review of your application for the renewal of Facility Operating License No. R-83, dated February 27, 2003 (a redacted version of the application, including the safety analysis report, is available on the NRC's public Web site at www.nrc.gov under Agencywide Documents Access and Management System Accession No. ML102920025), as supplemented, for the Texas Engineering Experiment Station/Texas A&M University System, Nuclear Science Center, TRIGA reactor. During our review, questions have arisen for which additional information is needed. The enclosed request for additional information identifies the additional information needed to complete our review.
We request that you provide responses to the enclosed RAI within 30 days from the date of this letter. In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 50.30(b), you must execute your response in a signed original document under oath or affirmation. Your response must be submitted in accordance with 10 CFR 50.4, "Written communications."  Information included in your response that is considered sensitive or proprietary, that you seek to have withheld from the public, must be marked in accordance with 10 CFR 2.390, "Public inspections, exemptions, requests for withholding."  Any information related to security should be submitted in accordance with 10 CFR 73.21, "Protection of Safeguards Information:  Performance Requirements."  Following receipt of the additional information, we will continue our evaluation of your renewal request.


S. McDeavitt - 2 -   If you have any questions, or need additional time to respond to this request, please contact me at (301) 415-0893 or by electronic mail at Geoffrey.Wertz@nrc.gov.
The U.S. Nuclear Regulatory Commission (NRC) is continuing its review of your application for the renewal of Facility Operating License No. R-83, dated February 27, 2003 (a redacted version of the application, including the safety analysis report, is available on the NRCs public Web site at www.nrc.gov under Agencywide Documents Access and Management System Accession No. ML102920025), as supplemented, for the Texas Engineering Experiment Station/Texas A&M University System, Nuclear Science Center, TRIGA reactor. During our review, questions have arisen for which additional information is needed. The enclosed request for additional information identifies the additional information needed to complete our review.
Sincerely,  
We request that you provide responses to the enclosed RAI within 30 days from the date of this letter.
      /Alexander Adams for RA/
In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 50.30(b), you must execute your response in a signed original document under oath or affirmation. Your response must be submitted in accordance with 10 CFR 50.4, Written communications. Information included in your response that is considered sensitive or proprietary, that you seek to have withheld from the public, must be marked in accordance with 10 CFR 2.390, Public inspections, exemptions, requests for withholding. Any information related to security should be submitted in accordance with 10 CFR 73.21, Protection of Safeguards Information: Performance Requirements. Following receipt of the additional information, we will continue our evaluation of your renewal request.
Geoffrey A. Wertz, Project Manager      Research and Test Reactors Licensing Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-128 Enclosure:
Request for Additional Information cc: See next page 


S. McDeavitt - 2 -  If you have any questions, or need additional time to respond to this request, please contact me at (301) 415-0893 or by electronic mail at Geoffrey.Wertz@nrc.gov.
S. McDeavitt                                   If you have any questions, or need additional time to respond to this request, please contact me at (301) 415-0893 or by electronic mail at Geoffrey.Wertz@nrc.gov.
Sincerely,  
Sincerely,
      /Alexander Adams for RA/
                                            /Alexander Adams for RA/
Geoffrey A. Wertz, Project Manager       Research and Test Reactors Licensing Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-128 Enclosure:
Geoffrey A. Wertz, Project Manager Research and Test Reactors Licensing Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-128
Request for Additional Information cc:  See next page 


DISTRIBUTION: PUBLIC    PRLB R/F  RidsNrrDprPrta Resource  AAdams, NRR RidsNrrDprPrtb Resource  GWertz, NRR  DHardesty, NRR RidsNrrDpr Resource  XYin, NRR  GMorlang, NRR  ADAMS Accession No.:  ML15125A280; *concurrence via email    NRR-106 OFFICIAL RECORD COPYOFFICE DPR/PRLB/PM DPR/LA DPR/PRLB/BC DPR/PRLB/PM NAME GWertz Elee (w/comment) AAdams (AAdams for) GWertz DATE 05/05/2015 05/06/2015 05/06/2015 05/06/2015 Texas A&M University Docket No. 50-128  cc:
==Enclosure:==
Mayor, City of College Station P.O. Box Drawer 9960 College Station, TX  77840-3575 Governor's Budget and  Planning Office P.O. Box 13561 Austin, TX  78711 ATTN:  Dr. Dimitris C. Lagoudas Deputy Director Texas A&M Engineering Experiment Station 241 Zachry Engineering Center 3577 TAMU College Station, TX  77843 ATTN:  Jerry Newhouse Assistant Director Nuclear Science Center Texas A&M Engineering Experiment Station 1095 Nuclear Science Road MS 3575 College Station, TX  77843


Radiation Program Officer Bureau of Radiation Control Dept. Of State Health Services Division for Regulatory Services 1100 West 49th Street, MC 2828 Austin, TX  78756-3189 Technical Advisor Office of Permitting, Remediation &
Request for Additional Information cc: See next page
Registration Texas Commission on Environmental Quality P.O. Box 13087, MS 122 Austin, TX  78711-3087


Test, Research and Training Reactor Newsletter 202 Nuclear Sciences Center University of Florida Gainesville, FL  32611 Greg Stasny Manager, Reactor Operations Texas A&M Engineering Experiment Station 1095 Nuclear Science Road MS 3575 College Station, TX 77843  
ML15125A280; *concurrence via email                          NRR-106 OFFICE      DPR/PRLB/PM    DPR/LA                  DPR/PRLB/BC          DPR/PRLB/PM NAME        GWertz          Elee (w/comment)        AAdams                (AAdams for) GWertz DATE        05/05/2015      05/06/2015              05/06/2015            05/06/2015 Texas A&M University                                              Docket No. 50-128 cc:
Mayor, City of College Station          Greg Stasny P.O. Box Drawer 9960                    Manager, Reactor Operations College Station, TX 77840-3575          Texas A&M Engineering Experiment Station 1095 Nuclear Science Road Governors Budget and                    MS 3575 Planning Office                        College Station, TX 77843 P.O. Box 13561 Austin, TX 78711                        State Energy Conservation Office Comptroller of Public Accounts ATTN: Dr. Dimitris C. Lagoudas          P.O. Box 13528 Deputy Director                          Austin, TX 78711-3528 Texas A&M Engineering Experiment Station 241 Zachry Engineering Center 3577 TAMU College Station, TX 77843 ATTN: Jerry Newhouse Assistant Director Nuclear Science Center Texas A&M Engineering Experiment Station 1095 Nuclear Science Road MS 3575 College Station, TX 77843 Radiation Program Officer Bureau of Radiation Control Dept. Of State Health Services Division for Regulatory Services 1100 West 49th Street, MC 2828 Austin, TX 78756-3189 Technical Advisor Office of Permitting, Remediation &
Registration Texas Commission on Environmental Quality P.O. Box 13087, MS 122 Austin, TX 78711-3087 Test, Research and Training Reactor Newsletter 202 Nuclear Sciences Center University of Florida Gainesville, FL 32611


State Energy Conservation Office Comptroller of Public Accounts P.O. Box 13528  Austin, TX  78711-3528 Enclosure OFFICE OF NUCLEAR REACTOR REGULATION REQUEST FOR ADDITIONAL INFORMATION FOR THE RENEWAL OF FACILITY OPERATING LICENSE NO. R-83 THE TEXAS ENGINEERING EXPERIMENT STATION/TEXAS A&M UNIVERSITY SYSTEM   NUCLEAR SCIENCE CENTER, TRIGA REACTOR DOCKET NO. 50-128 The U.S. Nuclear Regulatory Commission (NRC) is continuing its review of your application for the renewal of Facility Operating License No. R-83, dated February 27, 2003 (a redacted version of the application, including the safety analysis report (SAR), is available on the NRC's public Web site at www.nrc.gov under Agencywide Documents Access and Management System (ADAMS) Accession No. ML102920025), as supplemented, for the Texas Engineering Experiment Station/Texas A&M University System (TEES/TAMUS), Nuclear Science Center (NSC), TRIGA reactor. During our review, the following questions have arisen for which additional information is needed. Provide responses to these questions within 30 days from the date of this letter.  
OFFICE OF NUCLEAR REACTOR REGULATION REQUEST FOR ADDITIONAL INFORMATION FOR THE RENEWAL OF FACILITY OPERATING LICENSE NO. R-83 THE TEXAS ENGINEERING EXPERIMENT STATION/TEXAS A&M UNIVERSITY SYSTEM NUCLEAR SCIENCE CENTER, TRIGA REACTOR DOCKET NO. 50-128 The U.S. Nuclear Regulatory Commission (NRC) is continuing its review of your application for the renewal of Facility Operating License No. R-83, dated February 27, 2003 (a redacted version of the application, including the safety analysis report (SAR), is available on the NRCs public Web site at www.nrc.gov under Agencywide Documents Access and Management System (ADAMS) Accession No. ML102920025), as supplemented, for the Texas Engineering Experiment Station/Texas A&M University System (TEES/TAMUS), Nuclear Science Center (NSC), TRIGA reactor. During our review, the following questions have arisen for which additional information is needed. Provide responses to these questions within 30 days from the date of this letter.
: 1. The TEES/TAMUS updated SAR, dated June 9, 2011 (ADAMS Accession No. ML111950376), Section 7.2.3.4, Servo Control System, provides general information about the servo control system, but does not describe specific details associated with the operation or reactivity control aspects of the servo system. NUREG-1537, Part 1, Guidelines for Preparing and Reviewing Applications for the Licensing of Non-Power Reactors: Format and Content, Chapter 7.3, Reactor Control System, provides guidance that the license should analyze the operation and performance of the system, including the bases for any technical specifications and surveillance requirements, and provide a description of the evaluation of any accident scenarios that may be created by a malfunction of the system (e.g., a malfunction of the servo bounded by another reactivity insertion event).
: a. Provide details of the servo system operation including the normal reactivity control range, regulating rod position, interlocks, and any other significant design information, or justify why no additional information is necessary.
: b. Explain if additional technical specifications are needed for the servo system, or justify why no changes are necessary.
: 2. The TEES/TAMUS proposed Technical Specification (TS) 5.5, Radiation Monitoring System, Table 5, and TS 3.5.1, Radiation Monitoring, Table 3 (ADAMS Accession No. ML15065A068), states, in part, information regarding the Facility Air Monitors (FAMs),
Channels 1, 3, 4, and 5. However, the FAMs listed in Table 3 (channels 1, 3, and 4) do not match the FAM channels listed in Table 5 (channels 1, 3, 4, and 5). NUREG-1537, Part 1, Chapter 14, Appendix 14.1, Section 3.7.1, Monitoring Systems, provides guidance that the required radiation monitors should be listed in the TSs. Provide revised TSs addressing the Enclosure


1. The TEES/TAMUS updated SAR, dated June 9, 2011 (ADAMS Accession No. ML111950376), Section 7.2.3.4, "Servo Control System," provides general information about the servo control system, but does not describe specific details associated with the operation or reactivity control aspects of the servo system. NUREG-1537, Part 1, "Guidelines for Preparing and Reviewing Applications for the Licensing of Non-Power Reactors:  Format and Content," Chapter 7.3, "Reactor Control System," provides guidance that the license should analyze the operation and performance of the system, including the bases for any technical specifications and surveillance requirements, and provide a description of the evaluation of any accident scenarios that may be created by a malfunction of the system (e.g., a malfunction of the servo bounded by another reactivity insertion event). a. Provide details of the servo system operation including the normal reactivity control range, regulating rod position, interlocks, and any other significant design information, or justify why no additional information is necessary. b. Explain if additional technical specifications are needed for the servo system, or justify why no changes are necessary.
inconsistencies in the list of FAMs in Tables 3 and 5, or justify why no changes are necessary.
2. The TEES/TAMUS proposed Technical Specification (TS) 5.5, "Radiation Monitoring System," Table 5, and TS 3.5.1, "Radiation Monitoring," Table 3 (ADAMS Accession No. ML15065A068), states, in part, information regarding the Facility Air Monitors (FAMs), Channels 1, 3, 4, and 5. However, the FAMs listed in Table 3 (channels 1, 3, and 4) do not match the FAM channels listed in Table 5 (channels 1, 3, 4, and 5). NUREG-1537, Part 1, Chapter 14, Appendix 14.1, Section 3.7.1, "Monitoring Systems," provides guidance that the required radiation monitors should be listed in the TSs. Provide revised TSs addressing the
: 3. The TEES/TAMUS proposed TS 5.5, Radiation Monitoring System, Table 5, footnote (ADAMS Accession No. ML15065A068), states, in part, fission product monitor, but does not appear to be one of the FAM channels listed in Table 5, or TS 3.5.1, Table 3.
- 2 -  inconsistencies in the list of FAMs in Tables 3 and 5, or justify why no changes are necessary.
Furthermore, the TEES/TAMUS updated SAR, Section 7.7.2, Facility Air Monitors, describes the fission product monitor as FAM Channel 2. NUREG-1537, Part 1, Chapter 14, Appendix 14.1, Section 3.7.1, Monitoring Systems, provides guidance that the required radiation monitors should be listed in the TSs.
3. The TEES/TAMUS proposed TS 5.5, "Radiation Monitoring System," Table 5, footnote (ADAMS Accession No. ML15065A068), states, in part, "fission product monitor", but does not appear to be one of the FAM channels listed in Table 5, or TS 3.5.1, Table 3.
: a. Provide a description of the fission production monitor, consistent with the SAR description of the FAM channels, and
Furthermore, the TEES/TAMUS updated SAR, Section 7.7.2, "Facility Air Monitors," describes the fission product monitor as FAM Channel 2. NUREG-1537, Part 1, Chapter 14, Appendix 14.1, Section 3.7.1, "Monitoring Systems," provides guidance that the required radiation monitors should be listed in the TSs. a. Provide a description of the fission production monitor, consistent with the SAR description of the FAM channels, and b. Determine if the fission product monitor should be included in the TS 5.5, Table 5, and/or TS 3.5.1, Table 3. If so, provide revised TSs, or justify why no changes are necessary. 4. The TEES/TAMUS response to RAI No. 33.c, by letter dated March 2, 2015 (ADAMS Accession No. ML15065A068), provided information on the calculation of the setpoints for some of the FAM channels listed in proposed TS 5.5, Table 5. However, the calculation of the setpoint for FAM Channel No. 4 was not provided. Additionally, a description of how the setpoints ensure that personnel exposure and doses remain below the limits  of 10 CFR Part 20 was not provided. NUREG-1537, Part 1, Chapter 14, Appendix 14.1, Section 3.7.1, "Monitoring Systems," provides guidance that the alarm and automatic setpoints should be specified to ensure that personnel exposures and potential doses remain below the limits of 10 CFR Part 20. a. Provide the setpoint calculation for FAM Channel 4, similar to those provided for FAM Channels 1, 3, and 5. Include a setpoint calculation for the fission product monitor (FAM Channel 2), if added to the TSs based on the response to RAI 3 above, or justify why no additional information is necessary. b. Provide a description of the FAM channel setpoints for channels 1, 3, 4, and 5, that indicates how the setpoints ensure that personnel exposures and doses remain below the limits of 10 CFR Part 20. Include the fission product monitor, if the response to RAI No. 3 above adds the fission product monitor to the TSs, or justify why no changes are necessary. 5. The TEES/TAMUS proposed TS 3.5.1, "Radiation Monitoring," Specification (ADAMS Accession No. ML15065A068), states, in part, "The above operations-" which appear to be described in the Applicability section of TS 3.5.1. NUREG-1537, Part 1, Chapter 14, Appendix 14.1, Section 1.2.2, "Format," provides guidance that the Specification information should be provided in the specified format. Provide a revised TS 3.5.1, Specification that describes the operations intended by TS 3.5.1, or justify why no change is necessary.  
: b. Determine if the fission product monitor should be included in the TS 5.5, Table 5, and/or TS 3.5.1, Table 3. If so, provide revised TSs, or justify why no changes are necessary.
- 3 -  6. The TEES/TAMUS response to RAI No. 3, by letter dated November 14, 2012 (ADAMS Accession No. ML12321A321), provided the maximum exposure to an individual in an unrestricted area (at the fence line) that was based on the conservative assumption that the exposure was due to a total immersion in the plume generated from the immediate, ground level release of all fission products, from the reactor bay to the environment, that were produced by the Maximum Hypothetical Accident (MHA). Since the actual facility response to a significant radiological release would be to shutdown the exhaust system in order to limit the release of the MHA airborne radioactive material from the reactor bay, an additional calculation is needed to demonstrate the conservative assumptions provided by the plume model calculation. NUREG-1537, Part 1, Chapter 13, Section 13.1.1, "Maximum Hypothetical Accident," provides guidance that sensitivity analysis of the assumptions may be useful to determine more realistic results. Provide an estimate of the annual dose to a member of the public at the unrestricted area given that the MHA activity is confined in the reactor bay as a result of the isolation of the exhaust system (a simplified direct shine calculation assuming no leakage could be provided as a conservative estimate), or justify why no additional information is necessary. 7. The TEES/TAMUS proposed TS 1.3, "Definition," Pool Water Reference Operating Level (ADAMS Accession No. ML15065A068), states, in part, "the fission product air monitor."
: 4. The TEES/TAMUS response to RAI No. 33.c, by letter dated March 2, 2015 (ADAMS Accession No. ML15065A068), provided information on the calculation of the setpoints for some of the FAM channels listed in proposed TS 5.5, Table 5. However, the calculation of the setpoint for FAM Channel No. 4 was not provided. Additionally, a description of how the setpoints ensure that personnel exposure and doses remain below the limits of 10 CFR Part 20 was not provided. NUREG-1537, Part 1, Chapter 14, Appendix 14.1, Section 3.7.1, Monitoring Systems, provides guidance that the alarm and automatic setpoints should be specified to ensure that personnel exposures and potential doses remain below the limits of 10 CFR Part 20.
NUREG-1537, Part 1, Chapter 14, Appendix 14.1, Section 1.3, "Definitions" provides guidance that the definitions applicable to a facility should be included verbatim. With regard to the response to RAI No. 3 above, determine if a revision of the definition of Pool Water Reference Operating Level is necessary, and provide a revision to the TS Definition of Pool Water Reference Operating Level, or justify why no change is necessary.
: a. Provide the setpoint calculation for FAM Channel 4, similar to those provided for FAM Channels 1, 3, and 5. Include a setpoint calculation for the fission product monitor (FAM Channel 2), if added to the TSs based on the response to RAI 3 above, or justify why no additional information is necessary.
8. The TEES/TAMUS proposed TS 1.3, "Definition," Reactor Console Secured (ADAMS Accession No. ML15065A068), states, in part, that "whenever all scrammable rods-"
: b. Provide a description of the FAM channel setpoints for channels 1, 3, 4, and 5, that indicates how the setpoints ensure that personnel exposures and doses remain below the limits of 10 CFR Part 20. Include the fission product monitor, if the response to RAI No. 3 above adds the fission product monitor to the TSs, or justify why no changes are necessary.
However, the definition does not explain why it is limited to all scrammable rods and does not include all control rods. NUREG-1537, Part 1, Chapter 14, Appendix 14.1, Section 1.3, "Definitions" provides guidance that the definitions applicable to a facility should be included verbatim. Determine if a revision to the TS definition of Reactor Console Secured is needed to include all control rods, and provide a revised TS definition of Reactor Console Secured, or justify why no change is necessary. 9. The TEES/TAMUS proposed TS 1.3, "Definition," Reference Core Condition (ADAMS Accession No. ML15065A068), states, in part, "the reactivity worth of Xenon is negligible."
: 5. The TEES/TAMUS proposed TS 3.5.1, Radiation Monitoring, Specification (ADAMS Accession No. ML15065A068), states, in part, The above operations which appear to be described in the Applicability section of TS 3.5.1. NUREG-1537, Part 1, Chapter 14, Appendix 14.1, Section 1.2.2, Format, provides guidance that the Specification information should be provided in the specified format. Provide a revised TS 3.5.1, Specification that describes the operations intended by TS 3.5.1, or justify why no change is necessary.
However, negligible is not defined. NUREG-1537, Part 1, Chapter 14, Appendix 14.1, Section 1.3, "Definitions" provides guidance that the definitions applicable to a facility should be included verbatim. Provide a description of how TAMUS/TEES plans to implement the term "the reactivity worth of Xenon is negligible" in the definition of Reference Core Condition in operating procedures, or other guidance to the operators to ensure compliance with the TSs, or justify why no additional information is necessary.
: 6. The TEES/TAMUS response to RAI No. 3, by letter dated November 14, 2012 (ADAMS Accession No. ML12321A321), provided the maximum exposure to an individual in an unrestricted area (at the fence line) that was based on the conservative assumption that the exposure was due to a total immersion in the plume generated from the immediate, ground level release of all fission products, from the reactor bay to the environment, that were produced by the Maximum Hypothetical Accident (MHA). Since the actual facility response to a significant radiological release would be to shutdown the exhaust system in order to limit the release of the MHA airborne radioactive material from the reactor bay, an additional calculation is needed to demonstrate the conservative assumptions provided by the plume model calculation. NUREG-1537, Part 1, Chapter 13, Section 13.1.1, Maximum Hypothetical Accident, provides guidance that sensitivity analysis of the assumptions may be useful to determine more realistic results. Provide an estimate of the annual dose to a member of the public at the unrestricted area given that the MHA activity is confined in the reactor bay as a result of the isolation of the exhaust system (a simplified direct shine calculation assuming no leakage could be provided as a conservative estimate), or justify why no additional information is necessary.
10. The TEES/TAMUS proposed TS 3.2.2, "Reactor Systems and Interlocks," Specification (ADAMS Accession No. ML15065A068), states, in part, "any single safety channel or interlock may be inoperable with the reactor is operating-" may contain a typographic error. Consider if "with" should be changed to "when", or if another revision is needed, or justify why no change is necessary.
: 7. The TEES/TAMUS proposed TS 1.3, Definition, Pool Water Reference Operating Level (ADAMS Accession No. ML15065A068), states, in part, the fission product air monitor.
- 4 -  11. The TEES/TAMUS proposed TS 3.2.2, "Reactor Systems and Interlocks," Table 2b, Safety Channel, Pulse Stop Electro-Mechanical Interlock (ADAMS Accession No. ML15065A068), states the function is to prevent application of air to the Transient Rod unless the mechanical stop is installed. The corresponding Basis, Interlocks Required for Operation, item 5, states in part, that the interlock prevents application of air to the transient rod unless the cylinder is fully inserted. The TS 3.2.2, Pulse Stop Electro-Mechanical Interlock function and Basis description do not match. NUREG-1537, Part 1, Chapter 14, Appendix 14.1, Section 1.2.2, "Format," provides guidance that the Basis information should be provided in the specified format. Provide a revised TS 3.2.2 to correct the discrepancy between the Interlock function as described in Table 2b and the Basis item 5, or justify why no change is necessary. 12. The TEES/TAMUS proposed TS 3.3.2, "Equipment to Achieve Confinement," Specification 4 (ADAMS Accession No. ML15065A068), states, in part, "the fission product-facility air monitor."  With regard to the response to RAI No. 3 above, determine if a revision of the TS 3.3.2, Specification 4 is necessary, and provide a revision to TS 3.3.2, Specification 4, or justify why no change is necessary. 13. The TEES/TAMUS proposed TS 5.7, "Reactor Building and Central Exhaust System," Specification 3 (ADAMS Accession No. ML15065A068), states, in part, "the system shall be designed to shutdown in the event of an alarm on the stack particulate monitor (FAM Ch. 1)radiation monitoring channel."  The TEES/TAMUS updated SAR, Section 7.7.2, "Facility Air Monitors," indicates that FAM Channels 1, 2, and 5 automatically shutdown the facility air handling system. NUREG-1537, Part 1, Chapter 14, Appendix 14.1, Section 3.7.1, "Monitoring Systems," provides guidance that the required radiation monitors should be listed in the TSs. Provide a revised TS 5.7, Specification 3, which indicates which FAM channels automatically shutdown the facility air handling system, or justify why no change is necessary. 14. The TEES/TAMUS proposed TS 6.1.3, Specification 3.e. (ADAMS Accession No. ML15065A068), states, in part, "equal to or great-" which may contain a typographical error. Consider if "great" should be changed to "greater", if another revision is needed, or justify why no change is necessary.
NUREG-1537, Part 1, Chapter 14, Appendix 14.1, Section 1.3, Definitions provides guidance that the definitions applicable to a facility should be included verbatim. With regard to the response to RAI No. 3 above, determine if a revision of the definition of Pool Water Reference Operating Level is necessary, and provide a revision to the TS Definition of Pool Water Reference Operating Level, or justify why no change is necessary.
}}
: 8. The TEES/TAMUS proposed TS 1.3, Definition, Reactor Console Secured (ADAMS Accession No. ML15065A068), states, in part, that whenever all scrammable rods However, the definition does not explain why it is limited to all scrammable rods and does not include all control rods. NUREG-1537, Part 1, Chapter 14, Appendix 14.1, Section 1.3, Definitions provides guidance that the definitions applicable to a facility should be included verbatim. Determine if a revision to the TS definition of Reactor Console Secured is needed to include all control rods, and provide a revised TS definition of Reactor Console Secured, or justify why no change is necessary.
: 9. The TEES/TAMUS proposed TS 1.3, Definition, Reference Core Condition (ADAMS Accession No. ML15065A068), states, in part, the reactivity worth of Xenon is negligible.
However, negligible is not defined. NUREG-1537, Part 1, Chapter 14, Appendix 14.1, Section 1.3, Definitions provides guidance that the definitions applicable to a facility should be included verbatim. Provide a description of how TAMUS/TEES plans to implement the term the reactivity worth of Xenon is negligible in the definition of Reference Core Condition in operating procedures, or other guidance to the operators to ensure compliance with the TSs, or justify why no additional information is necessary.
: 10. The TEES/TAMUS proposed TS 3.2.2, Reactor Systems and Interlocks, Specification (ADAMS Accession No. ML15065A068), states, in part, any single safety channel or interlock may be inoperable with the reactor is operating may contain a typographic error.
Consider if with should be changed to when, or if another revision is needed, or justify why no change is necessary.
: 11. The TEES/TAMUS proposed TS 3.2.2, Reactor Systems and Interlocks, Table 2b, Safety Channel, Pulse Stop Electro-Mechanical Interlock (ADAMS Accession No. ML15065A068),
states the function is to prevent application of air to the Transient Rod unless the mechanical stop is installed. The corresponding Basis, Interlocks Required for Operation, item 5, states in part, that the interlock prevents application of air to the transient rod unless the cylinder is fully inserted. The TS 3.2.2, Pulse Stop Electro-Mechanical Interlock function and Basis description do not match. NUREG-1537, Part 1, Chapter 14, Appendix 14.1, Section 1.2.2, Format, provides guidance that the Basis information should be provided in the specified format. Provide a revised TS 3.2.2 to correct the discrepancy between the Interlock function as described in Table 2b and the Basis item 5, or justify why no change is necessary.
: 12. The TEES/TAMUS proposed TS 3.3.2, Equipment to Achieve Confinement, Specification 4 (ADAMS Accession No. ML15065A068), states, in part, the fission productfacility air monitor. With regard to the response to RAI No. 3 above, determine if a revision of the TS 3.3.2, Specification 4 is necessary, and provide a revision to TS 3.3.2, Specification 4, or justify why no change is necessary.
: 13. The TEES/TAMUS proposed TS 5.7, Reactor Building and Central Exhaust System, Specification 3 (ADAMS Accession No. ML15065A068), states, in part, the system shall be designed to shutdown in the event of an alarm on the stack particulate monitor (FAM Ch. 1) radiation monitoring channel. The TEES/TAMUS updated SAR, Section 7.7.2, Facility Air Monitors, indicates that FAM Channels 1, 2, and 5 automatically shutdown the facility air handling system. NUREG-1537, Part 1, Chapter 14, Appendix 14.1, Section 3.7.1, Monitoring Systems, provides guidance that the required radiation monitors should be listed in the TSs. Provide a revised TS 5.7, Specification 3, which indicates which FAM channels automatically shutdown the facility air handling system, or justify why no change is necessary.
: 14. The TEES/TAMUS proposed TS 6.1.3, Specification 3.e. (ADAMS Accession No. ML15065A068), states, in part, equal to or great which may contain a typographical error. Consider if great should be changed to greater, if another revision is needed, or justify why no change is necessary.}}

Latest revision as of 13:07, 5 February 2020

Texas Engineering Experiment Station/Texas A&M University System - Request for Additional Information Regarding the Renewal of Facility Operating License No. R-83 for the Nuclear Science Center Triga Reactor
ML15125A280
Person / Time
Site: 05000128
Issue date: 05/06/2015
From: Geoffrey Wertz
Research and Test Reactors Licensing Branch
To: Mcdeavitt S
Texas A&M Univ
McDeavitt S
References
TAC ME1584
Download: ML15125A280 (8)


Text

May 6, 2015 Dr. Sean McDeavitt, Director Nuclear Science Center Texas Engineering Experiment Station 1095 Nuclear Science Road MS 3575 College Station, TX 77843

SUBJECT:

TEXAS ENGINEERING EXPERIMENT STATION/TEXAS A&M UNIVERSITY SYSTEM - REQUEST FOR ADDITIONAL INFORMATION REGARDING THE RENEWAL OF FACILITY OPERATING LICENSE NO. R-83 FOR THE NUCLEAR SCIENCE CENTER TRIGA REACTOR (TAC NO. ME1584)

Dear Dr. McDeavitt:

The U.S. Nuclear Regulatory Commission (NRC) is continuing its review of your application for the renewal of Facility Operating License No. R-83, dated February 27, 2003 (a redacted version of the application, including the safety analysis report, is available on the NRCs public Web site at www.nrc.gov under Agencywide Documents Access and Management System Accession No. ML102920025), as supplemented, for the Texas Engineering Experiment Station/Texas A&M University System, Nuclear Science Center, TRIGA reactor. During our review, questions have arisen for which additional information is needed. The enclosed request for additional information identifies the additional information needed to complete our review.

We request that you provide responses to the enclosed RAI within 30 days from the date of this letter.

In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 50.30(b), you must execute your response in a signed original document under oath or affirmation. Your response must be submitted in accordance with 10 CFR 50.4, Written communications. Information included in your response that is considered sensitive or proprietary, that you seek to have withheld from the public, must be marked in accordance with 10 CFR 2.390, Public inspections, exemptions, requests for withholding. Any information related to security should be submitted in accordance with 10 CFR 73.21, Protection of Safeguards Information: Performance Requirements. Following receipt of the additional information, we will continue our evaluation of your renewal request.

S. McDeavitt If you have any questions, or need additional time to respond to this request, please contact me at (301) 415-0893 or by electronic mail at Geoffrey.Wertz@nrc.gov.

Sincerely,

/Alexander Adams for RA/

Geoffrey A. Wertz, Project Manager Research and Test Reactors Licensing Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-128

Enclosure:

Request for Additional Information cc: See next page

ML15125A280; *concurrence via email NRR-106 OFFICE DPR/PRLB/PM DPR/LA DPR/PRLB/BC DPR/PRLB/PM NAME GWertz Elee (w/comment) AAdams (AAdams for) GWertz DATE 05/05/2015 05/06/2015 05/06/2015 05/06/2015 Texas A&M University Docket No. 50-128 cc:

Mayor, City of College Station Greg Stasny P.O. Box Drawer 9960 Manager, Reactor Operations College Station, TX 77840-3575 Texas A&M Engineering Experiment Station 1095 Nuclear Science Road Governors Budget and MS 3575 Planning Office College Station, TX 77843 P.O. Box 13561 Austin, TX 78711 State Energy Conservation Office Comptroller of Public Accounts ATTN: Dr. Dimitris C. Lagoudas P.O. Box 13528 Deputy Director Austin, TX 78711-3528 Texas A&M Engineering Experiment Station 241 Zachry Engineering Center 3577 TAMU College Station, TX 77843 ATTN: Jerry Newhouse Assistant Director Nuclear Science Center Texas A&M Engineering Experiment Station 1095 Nuclear Science Road MS 3575 College Station, TX 77843 Radiation Program Officer Bureau of Radiation Control Dept. Of State Health Services Division for Regulatory Services 1100 West 49th Street, MC 2828 Austin, TX 78756-3189 Technical Advisor Office of Permitting, Remediation &

Registration Texas Commission on Environmental Quality P.O. Box 13087, MS 122 Austin, TX 78711-3087 Test, Research and Training Reactor Newsletter 202 Nuclear Sciences Center University of Florida Gainesville, FL 32611

OFFICE OF NUCLEAR REACTOR REGULATION REQUEST FOR ADDITIONAL INFORMATION FOR THE RENEWAL OF FACILITY OPERATING LICENSE NO. R-83 THE TEXAS ENGINEERING EXPERIMENT STATION/TEXAS A&M UNIVERSITY SYSTEM NUCLEAR SCIENCE CENTER, TRIGA REACTOR DOCKET NO. 50-128 The U.S. Nuclear Regulatory Commission (NRC) is continuing its review of your application for the renewal of Facility Operating License No. R-83, dated February 27, 2003 (a redacted version of the application, including the safety analysis report (SAR), is available on the NRCs public Web site at www.nrc.gov under Agencywide Documents Access and Management System (ADAMS) Accession No. ML102920025), as supplemented, for the Texas Engineering Experiment Station/Texas A&M University System (TEES/TAMUS), Nuclear Science Center (NSC), TRIGA reactor. During our review, the following questions have arisen for which additional information is needed. Provide responses to these questions within 30 days from the date of this letter.

1. The TEES/TAMUS updated SAR, dated June 9, 2011 (ADAMS Accession No. ML111950376), Section 7.2.3.4, Servo Control System, provides general information about the servo control system, but does not describe specific details associated with the operation or reactivity control aspects of the servo system. NUREG-1537, Part 1, Guidelines for Preparing and Reviewing Applications for the Licensing of Non-Power Reactors: Format and Content, Chapter 7.3, Reactor Control System, provides guidance that the license should analyze the operation and performance of the system, including the bases for any technical specifications and surveillance requirements, and provide a description of the evaluation of any accident scenarios that may be created by a malfunction of the system (e.g., a malfunction of the servo bounded by another reactivity insertion event).
a. Provide details of the servo system operation including the normal reactivity control range, regulating rod position, interlocks, and any other significant design information, or justify why no additional information is necessary.
b. Explain if additional technical specifications are needed for the servo system, or justify why no changes are necessary.
2. The TEES/TAMUS proposed Technical Specification (TS) 5.5, Radiation Monitoring System, Table 5, and TS 3.5.1, Radiation Monitoring, Table 3 (ADAMS Accession No. ML15065A068), states, in part, information regarding the Facility Air Monitors (FAMs),

Channels 1, 3, 4, and 5. However, the FAMs listed in Table 3 (channels 1, 3, and 4) do not match the FAM channels listed in Table 5 (channels 1, 3, 4, and 5). NUREG-1537, Part 1, Chapter 14, Appendix 14.1, Section 3.7.1, Monitoring Systems, provides guidance that the required radiation monitors should be listed in the TSs. Provide revised TSs addressing the Enclosure

inconsistencies in the list of FAMs in Tables 3 and 5, or justify why no changes are necessary.

3. The TEES/TAMUS proposed TS 5.5, Radiation Monitoring System, Table 5, footnote (ADAMS Accession No. ML15065A068), states, in part, fission product monitor, but does not appear to be one of the FAM channels listed in Table 5, or TS 3.5.1, Table 3.

Furthermore, the TEES/TAMUS updated SAR, Section 7.7.2, Facility Air Monitors, describes the fission product monitor as FAM Channel 2. NUREG-1537, Part 1, Chapter 14, Appendix 14.1, Section 3.7.1, Monitoring Systems, provides guidance that the required radiation monitors should be listed in the TSs.

a. Provide a description of the fission production monitor, consistent with the SAR description of the FAM channels, and
b. Determine if the fission product monitor should be included in the TS 5.5, Table 5, and/or TS 3.5.1, Table 3. If so, provide revised TSs, or justify why no changes are necessary.
4. The TEES/TAMUS response to RAI No. 33.c, by letter dated March 2, 2015 (ADAMS Accession No. ML15065A068), provided information on the calculation of the setpoints for some of the FAM channels listed in proposed TS 5.5, Table 5. However, the calculation of the setpoint for FAM Channel No. 4 was not provided. Additionally, a description of how the setpoints ensure that personnel exposure and doses remain below the limits of 10 CFR Part 20 was not provided. NUREG-1537, Part 1, Chapter 14, Appendix 14.1, Section 3.7.1, Monitoring Systems, provides guidance that the alarm and automatic setpoints should be specified to ensure that personnel exposures and potential doses remain below the limits of 10 CFR Part 20.
a. Provide the setpoint calculation for FAM Channel 4, similar to those provided for FAM Channels 1, 3, and 5. Include a setpoint calculation for the fission product monitor (FAM Channel 2), if added to the TSs based on the response to RAI 3 above, or justify why no additional information is necessary.
b. Provide a description of the FAM channel setpoints for channels 1, 3, 4, and 5, that indicates how the setpoints ensure that personnel exposures and doses remain below the limits of 10 CFR Part 20. Include the fission product monitor, if the response to RAI No. 3 above adds the fission product monitor to the TSs, or justify why no changes are necessary.
5. The TEES/TAMUS proposed TS 3.5.1, Radiation Monitoring, Specification (ADAMS Accession No. ML15065A068), states, in part, The above operations which appear to be described in the Applicability section of TS 3.5.1. NUREG-1537, Part 1, Chapter 14, Appendix 14.1, Section 1.2.2, Format, provides guidance that the Specification information should be provided in the specified format. Provide a revised TS 3.5.1, Specification that describes the operations intended by TS 3.5.1, or justify why no change is necessary.
6. The TEES/TAMUS response to RAI No. 3, by letter dated November 14, 2012 (ADAMS Accession No. ML12321A321), provided the maximum exposure to an individual in an unrestricted area (at the fence line) that was based on the conservative assumption that the exposure was due to a total immersion in the plume generated from the immediate, ground level release of all fission products, from the reactor bay to the environment, that were produced by the Maximum Hypothetical Accident (MHA). Since the actual facility response to a significant radiological release would be to shutdown the exhaust system in order to limit the release of the MHA airborne radioactive material from the reactor bay, an additional calculation is needed to demonstrate the conservative assumptions provided by the plume model calculation. NUREG-1537, Part 1, Chapter 13, Section 13.1.1, Maximum Hypothetical Accident, provides guidance that sensitivity analysis of the assumptions may be useful to determine more realistic results. Provide an estimate of the annual dose to a member of the public at the unrestricted area given that the MHA activity is confined in the reactor bay as a result of the isolation of the exhaust system (a simplified direct shine calculation assuming no leakage could be provided as a conservative estimate), or justify why no additional information is necessary.
7. The TEES/TAMUS proposed TS 1.3, Definition, Pool Water Reference Operating Level (ADAMS Accession No. ML15065A068), states, in part, the fission product air monitor.

NUREG-1537, Part 1, Chapter 14, Appendix 14.1, Section 1.3, Definitions provides guidance that the definitions applicable to a facility should be included verbatim. With regard to the response to RAI No. 3 above, determine if a revision of the definition of Pool Water Reference Operating Level is necessary, and provide a revision to the TS Definition of Pool Water Reference Operating Level, or justify why no change is necessary.

8. The TEES/TAMUS proposed TS 1.3, Definition, Reactor Console Secured (ADAMS Accession No. ML15065A068), states, in part, that whenever all scrammable rods However, the definition does not explain why it is limited to all scrammable rods and does not include all control rods. NUREG-1537, Part 1, Chapter 14, Appendix 14.1, Section 1.3, Definitions provides guidance that the definitions applicable to a facility should be included verbatim. Determine if a revision to the TS definition of Reactor Console Secured is needed to include all control rods, and provide a revised TS definition of Reactor Console Secured, or justify why no change is necessary.
9. The TEES/TAMUS proposed TS 1.3, Definition, Reference Core Condition (ADAMS Accession No. ML15065A068), states, in part, the reactivity worth of Xenon is negligible.

However, negligible is not defined. NUREG-1537, Part 1, Chapter 14, Appendix 14.1, Section 1.3, Definitions provides guidance that the definitions applicable to a facility should be included verbatim. Provide a description of how TAMUS/TEES plans to implement the term the reactivity worth of Xenon is negligible in the definition of Reference Core Condition in operating procedures, or other guidance to the operators to ensure compliance with the TSs, or justify why no additional information is necessary.

10. The TEES/TAMUS proposed TS 3.2.2, Reactor Systems and Interlocks, Specification (ADAMS Accession No. ML15065A068), states, in part, any single safety channel or interlock may be inoperable with the reactor is operating may contain a typographic error.

Consider if with should be changed to when, or if another revision is needed, or justify why no change is necessary.

11. The TEES/TAMUS proposed TS 3.2.2, Reactor Systems and Interlocks, Table 2b, Safety Channel, Pulse Stop Electro-Mechanical Interlock (ADAMS Accession No. ML15065A068),

states the function is to prevent application of air to the Transient Rod unless the mechanical stop is installed. The corresponding Basis, Interlocks Required for Operation, item 5, states in part, that the interlock prevents application of air to the transient rod unless the cylinder is fully inserted. The TS 3.2.2, Pulse Stop Electro-Mechanical Interlock function and Basis description do not match. NUREG-1537, Part 1, Chapter 14, Appendix 14.1, Section 1.2.2, Format, provides guidance that the Basis information should be provided in the specified format. Provide a revised TS 3.2.2 to correct the discrepancy between the Interlock function as described in Table 2b and the Basis item 5, or justify why no change is necessary.

12. The TEES/TAMUS proposed TS 3.3.2, Equipment to Achieve Confinement, Specification 4 (ADAMS Accession No. ML15065A068), states, in part, the fission productfacility air monitor. With regard to the response to RAI No. 3 above, determine if a revision of the TS 3.3.2, Specification 4 is necessary, and provide a revision to TS 3.3.2, Specification 4, or justify why no change is necessary.
13. The TEES/TAMUS proposed TS 5.7, Reactor Building and Central Exhaust System, Specification 3 (ADAMS Accession No. ML15065A068), states, in part, the system shall be designed to shutdown in the event of an alarm on the stack particulate monitor (FAM Ch. 1) radiation monitoring channel. The TEES/TAMUS updated SAR, Section 7.7.2, Facility Air Monitors, indicates that FAM Channels 1, 2, and 5 automatically shutdown the facility air handling system. NUREG-1537, Part 1, Chapter 14, Appendix 14.1, Section 3.7.1, Monitoring Systems, provides guidance that the required radiation monitors should be listed in the TSs. Provide a revised TS 5.7, Specification 3, which indicates which FAM channels automatically shutdown the facility air handling system, or justify why no change is necessary.
14. The TEES/TAMUS proposed TS 6.1.3, Specification 3.e. (ADAMS Accession No. ML15065A068), states, in part, equal to or great which may contain a typographical error. Consider if great should be changed to greater, if another revision is needed, or justify why no change is necessary.