Other: ML102650318, ML120190004, ML120190007, ML13007A425, ML13017A049, ML13030A426, ML14064A348, ML14076A112, ML14092A444, ML14183A012, ML15092A962, ML15187A256, ML15289A596, NRC-2015-0210, General Notice: FRN Texas Engineering Experiment Station/Texas a & M University System - Environmental Assessment Renewal of Facility Operating License No. R-83 for the Nuclear Science Center Reactor
|
MONTHYEARML0925303062009-07-22022 July 2009 Redacted Safety Analysis Report for Texas A&M Application for License Renewal and Power Uprate Including Technical Specifications and Environmental Report Project stage: Request ML0929903922009-11-13013 November 2009 Texas A&M University, Request for Additional Information (Financial Qualification), License Renewal Project stage: RAI NRC-2010-0220, FRN: General Notice. Texas Engineering Experiment Station, Notice of Acceptance for Docketing of Application and Opportunity for Hearing2010-06-21021 June 2010 FRN: General Notice. Texas Engineering Experiment Station, Notice of Acceptance for Docketing of Application and Opportunity for Hearing Project stage: Acceptance Review ML1013301222010-06-21021 June 2010 FRN: General Notice. Texas Engineering Experiment Station, Notice of Acceptance for Docketing of Application and Opportunity for Hearing Project stage: Acceptance Review ML1010604342010-06-24024 June 2010 Texas A&M System, Texas Engineering Experiment Station, Request for Additional Information Regarding License Renewal Project stage: RAI ML1011707092010-06-24024 June 2010 Texas A&M Request for Additional Information, Enclosure 2 - Public Project stage: RAI ML1013301392010-06-29029 June 2010 Texas Engineering Experiment Station, Letter to Licensee Notice of Acceptance for Docketing of Application and Opportunity for Hearing (Tac ME1584) Project stage: Acceptance Review ML1026503182010-08-31031 August 2010 Texas a & M University System, Redacted - Response to NRC Non-Financial Requests for Additional Information Questions 1-37 for the Tees Nuclear Science Center Reactor Project stage: Other ML1027704952010-10-0606 October 2010 Texas A&M System, Texas Engineering Experiment Station - Request for Additional Information Regarding the Nuclear Science Center Reactor License Renewal Project stage: RAI ML1127000062011-09-29029 September 2011 Texas A&M System, Texas Engineering Experiment Station - Request for Additional Information License Renewal of Facility Operating License No. R-83 Project stage: RAI ML14183A0122011-11-21021 November 2011 Texas A&M University System/Texas Engineering Experiment Station Nuclear Science Center Redacted Version of Letter Dated November 11, 2011 Project stage: Other ML1201005132012-01-11011 January 2012 Texas A&M System, Texas Engineering Experiment Station, NRC Request for Additional Information License Renewal Project stage: RAI ML1202600162012-01-12012 January 2012 Texas A&M University System, Texas Engineering Experiment Station - *Redacted* Responses to NRC Request for Additional Information Questions 1 and 3 (Tac No. ME1584) Project stage: Response to RAI ML13007A4252013-01-0404 January 2013 University of Missouri-Columbia Research Reactor - License Amendment Application: Operator Requalification Program Project stage: Other ML13007A4262013-01-0404 January 2013 Written Communication as Specified by 10 CFR 50.4 Regarding the Response to the University of Missouri, Columbia - Request for Copy of the Physical Security Plan and Operator Requalification Program, License Renewal (TAC No. ME1584), Dtd 12 Project stage: Request ML13017A0492013-01-10010 January 2013 1/10/2013 - Memo to File Conf. Call with Texas a & M Dr. Reece and NRC Staff to Discuss License Condition Changes for License Renewal Project stage: Other ML13330B0062013-12-0505 December 2013 Texas Engineering Experiment Station/Texas A&M University System - Request for Additional Information Updated Financial Information for License Renewal Project stage: RAI ML13340A7382014-01-0707 January 2014 Texas Engineering Experiment Station/Texas A&M University System - Request for Additional Information Emergency Preparedness Plan Review for License Renewal Project stage: RAI ML13361A2522014-01-0808 January 2014 Texas Engineering Experiment Station/Texas A&M University System - Request for Additional Information Operator Requalification Program Review for License Renewal Project stage: RAI ML14076A1122014-02-11011 February 2014 Response to USNRC Requests for Additional Information RAI 1-6, Operator Requalification Program, from the Texas A&M University System, Texas Engineering Experiment Station, Nuclear Science Center Reactor (NSCR, License No. R-83, Docket 50-1 Project stage: Other ML14064A3482014-02-11011 February 2014 Response to USNRC Requests for Additional Information RAI 1-3, Emergency Preparedness Plan, from the Texas A&M University System, Texas Engineering Experiment Station, Nuclear Science Center Reactor (NSCR, License No. R-83, Docket 50-128) Project stage: Other ML14092A4442014-04-10010 April 2014 Texas Engineering Experiment Station/Texas A&M University System, Nuclear Science Center - Approval of the Nuclear Science Center Senior Reactor Operator and Reactor Operator Requalification Program Project stage: Other ML14115A1632014-05-0505 May 2014 Texas Engineering Experiment Station/Texas A&M University System, Nuclear Science Center Review of the Emergency Preparedness Plan for License Renewal Project stage: Approval ML14168A1582014-06-19019 June 2014 Texas A&M University System/Texas Engineering Experiment Station Nuclear Science Center Transmittal Letter Request for Additional Information for the Physical Security Plan Review for License Renewal Project stage: RAI ML14192A2012014-07-15015 July 2014 Texas Engineering Experiment Station/Texas A&M University System - Request for Additional Information Review of the Fuel Pool Temperature on Fuel Temperature for License Renewal for the NSC Triga Reactor Project stage: RAI ML14293A4492014-11-0505 November 2014 Texas Engineering Experiment Station/Texas A&M University System - Request for Additional Information Regarding the Review Renewal for Facility Operating License R-83 for the Nuclear Science Center Triga Reactor Project stage: RAI ML15009A2792014-11-13013 November 2014 Response to U.S. NRC Request for Additional Information, Review of the Fuel Pool Temperature on Fuel Temperature for the License Renewal for the Nuclear Science Center Triga Reactor (TAC Me 1584), from the Texas A&M University System, Texas Project stage: Request ML14316A3932014-11-14014 November 2014 Texas A&M University System/Texas Engineering Experiment Station Nuclear Science Center Request for Additional Information for the Physical Security Plan Review for License Renewal (Cover Letter) Project stage: RAI ML15065A0682015-03-0202 March 2015 Texas A&M University - Response to Us NRC Request for Additional Information Regarding the Renewal of Facility Operating License No. R-83 for the Nuclear Science Center Triga Reactor Project stage: Request ML15092A9622015-04-15015 April 2015 Texas A&M University Training, Research, Isotopes, General Atomics Reactor Suspension of Experiments Under Technical Specification 3.5.3, Xenon and Iodine Monitoring and 3.6.4, Xenon Irradiation for Iodine Production Project stage: Other ML15125A2802015-05-0606 May 2015 Texas Engineering Experiment Station/Texas A&M University System - Request for Additional Information Regarding the Renewal of Facility Operating License No. R-83 for the Nuclear Science Center Triga Reactor Project stage: RAI ML15160A0232015-06-0505 June 2015 Texas A&M University - Response to U.S. NRC Request for Additional Information Regarding the Renewal of Facility Operating License No. R-83 Project stage: Request ML15187A2562015-06-30030 June 2015 Email to Correct Updated Proposed Tees TS from Jerry Newhouse 6.30.15 Project stage: Other NRC-2015-0210, General Notice: FRN Texas Engineering Experiment Station/Texas a & M University System - Environmental Assessment Renewal of Facility Operating License No. R-83 for the Nuclear Science Center Reactor2015-08-24024 August 2015 General Notice: FRN Texas Engineering Experiment Station/Texas a & M University System - Environmental Assessment Renewal of Facility Operating License No. R-83 for the Nuclear Science Center Reactor Project stage: Other ML1201900072015-08-24024 August 2015 General Notice: FRN Texas Engineering Experiment Station/Texas a & M University System - Environmental Assessment Renewal of Facility Operating License No. R-83 for the Nuclear Science Center Reactor Project stage: Other ML1201900042015-08-24024 August 2015 Texas Engineering Experiment Station/Texas A&M University System - Enviornmental Assessment Renewal of Facility Operating License No. R-83 Project stage: Other ML15289A5962015-09-30030 September 2015 NRC Form 669 Conversation Record Texas A&M University System, Texas Engineering Experiment Station, Nuclear Science Center Reactor Change to the Technical Specification 6.8.1 (NSCR, License No. R-83, Docket 50-128) Project stage: Other ML13030A4262015-10-0101 October 2015 Texas Engineering Experiment Station/Texas A&M University System - Technical Specifications Appendix a Renewed Facility Operating License R-83 Dated October 1, 2015 (Tac No. ME1584) Project stage: Other ML13030A4482015-10-0101 October 2015 Texas Engineering Experiment Station/Texas A&M University - Safety Evaluation Report for Renewed Facility Operating License (Tac No. ME1584) Project stage: Approval ML13030A4102015-10-0101 October 2015 Texas Engineering Experiment Station/Texas A&M University System - Issuance of Renewed Facility Operating License No. R-83 (Tac No. ME1584) Project stage: Approval ML13031A0312015-10-15015 October 2015 FRN: General Notice - Texas Engineering Experiment Station/Texas A&M University System - Notice of Issuance of Renewed Facility Operating License No. R-83 (Tac No. ME1584) Project stage: Approval 2014-11-13
[Table View] |
Text
October 6, 2010 Dr. W. D. Reece, Director Nuclear Science Center Texas Engineering Experiment Station Texas A&M University 1095 Nuclear Science Road F.E. Box 89, M/S 3575 College Station, Texas 77843
SUBJECT:
TEXAS A&M SYSTEM, TEXAS ENGINEERING EXPERIMENT STATION -
REQUEST FOR ADDITIONAL INFORMATION REGARDING THE NUCLEAR SCIENCE CENTER REACTOR LICENSE RENEWAL (TAC NO. ME1584)
Dear Dr. Reece:
The U. S. Nuclear Regulatory Commission (NRC) completed its review of your letter dated August 31, 2010 in response to our letter dated June 24, 2010, requesting additional information. This review was performed in support of your application for renewal of Facility Operating License No. R-83 for the Nuclear Science Center Reactor (NSC) dated February 27, 2003, as supplemented by letters dated March 30, 2005, and July 22, 2009.
During our review, we find that some of the responses to our request for additional information were incomplete. The enclosed request for additional information identifies the additional information needed to complete our review. For your information, the enclosed do not contain any request beyond those already asked in our June 24, 2010, letter. Also for ease of review, the request numbers are kept the same.
Please provide responses to the enclosed request for additional information within 30 days of the date of this letter or as soon as possible. In accordance with Title 10 of the Code of Federal Regulations Section 50.30(b), your response must be executed in a signed original under oath or affirmation.
If you have any questions regarding this review, please contact A. Frank DiMeglio at 301-415-0894 or by electronic mail at francis.dimeglio@nrc.gov.
Sincerely,
/RA/
Linh N. Tran, Senior Project Manager Research and Test Reactors Licensing Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-128
Enclosure:
As Stated
Texas A&M University Docket No. 50-128 cc:
Mayor, City of College Station P.O. Box Drawer 9960 College Station, TX 77840-3575 Governors Budget and Planning Office P.O. Box 13561 Austin, TX 78711 Texas A&M University System ATTN: Jim Remlinger, Associate Director Nuclear Science Center Texas Engineering Experiment Station F. E. Box 89, M/S 3575 College Station, Texas 77843 Radiation Program Officer Bureau of Radiation Control Dept. Of State Health Services Division for Regulatory Services 1100 West 49th Street, MC 2828 Austin, TX 78756-3189 Susan M. Jablonski Technical Advisor Office of Permitting, Remediation & Registration Texas Commission on Environmental Quality P.O. Box 13087, MS 122 Austin, TX 78711-3087 Test, Research and Training Reactor Newsletter 202 Nuclear Sciences Center University of Florida Gainesville, FL 32611
ML102770495 TEMPLATE # NRR-088 OFFICE PRLB :PM PRLB: PM PRPB: LA PRLB: ABC PRLB: PM NAME FDiMeglio LTran GLappert JQuichocho LTran DATE 10/5/2010 10/5/2010 10/5/2010 10/5/2010 10/6/2010
ENCLOSURE OFFICE OF NUCLEAR REACTOR REGULATION REQUEST FOR ADDITIONAL INFORMATION TEXAS A&M UNIVERSITY TEXAS ENGINEERING EXPERIMENT STATION NUCLEAR SCIENCE CENTER REACTOR FACILITY OPERATING LICENSE NO. R-83 DOCKET NO. 50-128 The U. S. Nuclear Regulatory Commission (NRC) completed its review of the response provided by The Texas A&M University (the licensee) in a letter dated August 31, 2010. The NRC determined that some of the responses to the requests for additional information provided by the licensee were incomplete. In order for the NRC to complete its review, the licensee is requested to provide additional information as identified below:
RAI 1
The response provided for RAI 1 is incomplete in that while stating that there is a temperature indication available to the reactor operator, there is not a technical specification, an administrative procedure, or an operating procedure for the required actions following a temperature limit being reached. In addition, while it is proposed in the response to allow the inlet coolant temperature to increase beyond the temperature currently in the Texas A&M Safety Analysis Report, there is no consideration of the effect of this increased temperature on reactor components. Please provide a technical specification (TS), administrative control, or operating procedure for the maximum inlet temperature and consider the effect of increased temperature on reactor components.
RAI 10
The response provided for RAI 10 is incomplete in that the proposed TS does not reflect the maximum licensed power level of the reactor. Please revise the proposed TS to reflect the maximum licensed power level of the reactor.
RAI 13
The response to RAI 13 is ambiguous in that it suggests that the 1 kW interlock may be checked after maintenance by operating the reactor. Please provide clarification for this response.
RAI14 The response provided for RAI 14 is incomplete as follows:
The response to item (3) and (4) is incomplete because it does not establish a limiting condition for operation (LCO). Please provide a LCO for minimum amount of water above the core and pool water level monitoring.
The current TS have a LCO on pool water pH. The response has removed the LCO on pool water pH. Please provide an explanation as to why this LCO should not be retained.
RAI 18
The response to RAI 18 is incomplete in that the Basis provided for the technical specification revision is ambiguous. Please provide clarification for the statement concerning a safety factor of 2.0 or greater.
RAI 22
The response to RAI 22 is incomplete in that adequate justification is not provided for removing the limitations of the pool water pH. Please reconsider retaining the LCO on pool water pH or provide justification why it is not needed.
RAI 23
The response to RAI 23 is inadequate as follows:
TS 14.4.8, Specification 7 refers to TS 14.4.3.2, Reactor Safety Systems and except pool level. TS 14.4.3.2 does not contain a specification on pool level. Please provide clarification for this specification.
TS 14.4.8, Specification 9 refers to TS 14.4.4.1, Coolant Radioactivity Analysis allows for deferral of determination of coolant radioactivity analysis. This appears to be a contradiction of the Basis for TS 14.4.8, Specification 5. Please provide justification for deferment of coolant radioactivity analysis.
TS 14.4.8, Specification 10 refers to TS 14.4.4.2, Coolant conductivity allows for deferral of measurement of coolant conductivity. Please provide justification for deferment of coolant conductivity determination.
RAI 28
The response to RAI 28 is incomplete in that it does not specify limits on coolant pH. In addition, response 2) is ambiguous and requires clarification. Please provide this additional information.
RAI 29
The response to RAI 29 is incomplete in that it does not state whether the filter bank is part of the ventilation system which is used to achieve building confinement. The components of the ventilation system including a filter bank would require an LCO and surveillance even if no credit is taken for filtration in analysis. Please amend the response to RAI 29 to include the filter bank or justify why the inclusion is not needed.
RAI 30
The response to RAI 30 is a proposed TS concerning the TAMU site. Please review the proposed TS for sensitive information which should be withheld and not be included in the TS.
RAI31 The response to RAI 31 is unclear in that it appears to allow a maintenance technician who is not a licensed reactor operator to be performing maintenance on the unsecured reactor with the Senior Reactor Operator somewhere on site. This places the non licensed maintenance technician in control of the unsecured reactor. Please provide clarification for this response.
RAI 32
The response to RAI 32 is incomplete in that it does not show consistency with ANSI/ANS-15.4-1988 (R1999) nor endorse it. Please provide clarification this response.
RAI 33
The response to RAI 33 proposed a new proposed TS concerning the Reactor Safety Board. However, the response is incomplete. From the proposed TS, it appears that in the absence of the Chairman, a committee meeting can be held with a quorum of two voting individuals. In addition, the meeting frequency specified in the Facility Operating License No. 83 and the proposed TS differ. The proposed TS does not provide for the use of subcommittees and for the review, approval, and dissemination of minutes which are provided for in the current TS. The proposed TS does not clearly state that the ex-officio members do not vote. Please provide clarification for the proposed TS.
RAI 35
The response to RAI 35 is incomplete in that it does not include all surveillance procedures in proposed TS 14.6.3. For examples: surveillance procedures for shipping of radioactive materials and maintenance of major components of systems that could have an effect on reactor safety. Please review and revise proposed