Letter Sequence RAI |
|---|
|
Results
Other: ML102650318, ML120190004, ML120190007, ML13007A425, ML13017A049, ML13030A426, ML14064A348, ML14076A112, ML14092A444, ML14183A012, ML15092A962, ML15187A256, ML15289A596, NRC-2015-0210, General Notice: FRN Texas Engineering Experiment Station/Texas a & M University System - Environmental Assessment Renewal of Facility Operating License No. R-83 for the Nuclear Science Center Reactor
|
MONTHYEARML0925303062009-07-22022 July 2009 Redacted Safety Analysis Report for Texas A&M Application for License Renewal and Power Uprate Including Technical Specifications and Environmental Report Project stage: Request ML0929903922009-11-13013 November 2009 Texas A&M University, Request for Additional Information (Financial Qualification), License Renewal Project stage: RAI NRC-2010-0220, FRN: General Notice. Texas Engineering Experiment Station, Notice of Acceptance for Docketing of Application and Opportunity for Hearing2010-06-21021 June 2010 FRN: General Notice. Texas Engineering Experiment Station, Notice of Acceptance for Docketing of Application and Opportunity for Hearing Project stage: Acceptance Review ML1013301222010-06-21021 June 2010 FRN: General Notice. Texas Engineering Experiment Station, Notice of Acceptance for Docketing of Application and Opportunity for Hearing Project stage: Acceptance Review ML1010604342010-06-24024 June 2010 Texas A&M System, Texas Engineering Experiment Station, Request for Additional Information Regarding License Renewal Project stage: RAI ML1011707092010-06-24024 June 2010 Texas A&M Request for Additional Information, Enclosure 2 - Public Project stage: RAI ML1013301392010-06-29029 June 2010 Texas Engineering Experiment Station, Letter to Licensee Notice of Acceptance for Docketing of Application and Opportunity for Hearing (Tac ME1584) Project stage: Acceptance Review ML1026503182010-08-31031 August 2010 Texas a & M University System, Redacted - Response to NRC Non-Financial Requests for Additional Information Questions 1-37 for the Tees Nuclear Science Center Reactor Project stage: Other ML1027704952010-10-0606 October 2010 Texas A&M System, Texas Engineering Experiment Station - Request for Additional Information Regarding the Nuclear Science Center Reactor License Renewal Project stage: RAI ML1127000062011-09-29029 September 2011 Texas A&M System, Texas Engineering Experiment Station - Request for Additional Information License Renewal of Facility Operating License No. R-83 Project stage: RAI ML14183A0122011-11-21021 November 2011 Texas A&M University System/Texas Engineering Experiment Station Nuclear Science Center Redacted Version of Letter Dated November 11, 2011 Project stage: Other ML1201005132012-01-11011 January 2012 Texas A&M System, Texas Engineering Experiment Station, NRC Request for Additional Information License Renewal Project stage: RAI ML1202600162012-01-12012 January 2012 Texas A&M University System, Texas Engineering Experiment Station - *Redacted* Responses to NRC Request for Additional Information Questions 1 and 3 (Tac No. ME1584) Project stage: Response to RAI ML13007A4252013-01-0404 January 2013 University of Missouri-Columbia Research Reactor - License Amendment Application: Operator Requalification Program Project stage: Other ML13007A4262013-01-0404 January 2013 Written Communication as Specified by 10 CFR 50.4 Regarding the Response to the University of Missouri, Columbia - Request for Copy of the Physical Security Plan and Operator Requalification Program, License Renewal (TAC No. ME1584), Dtd 12 Project stage: Request ML13017A0492013-01-10010 January 2013 1/10/2013 - Memo to File Conf. Call with Texas a & M Dr. Reece and NRC Staff to Discuss License Condition Changes for License Renewal Project stage: Other ML13330B0062013-12-0505 December 2013 Texas Engineering Experiment Station/Texas A&M University System - Request for Additional Information Updated Financial Information for License Renewal Project stage: RAI ML13340A7382014-01-0707 January 2014 Texas Engineering Experiment Station/Texas A&M University System - Request for Additional Information Emergency Preparedness Plan Review for License Renewal Project stage: RAI ML13361A2522014-01-0808 January 2014 Texas Engineering Experiment Station/Texas A&M University System - Request for Additional Information Operator Requalification Program Review for License Renewal Project stage: RAI ML14076A1122014-02-11011 February 2014 Response to USNRC Requests for Additional Information RAI 1-6, Operator Requalification Program, from the Texas A&M University System, Texas Engineering Experiment Station, Nuclear Science Center Reactor (NSCR, License No. R-83, Docket 50-1 Project stage: Other ML14064A3482014-02-11011 February 2014 Response to USNRC Requests for Additional Information RAI 1-3, Emergency Preparedness Plan, from the Texas A&M University System, Texas Engineering Experiment Station, Nuclear Science Center Reactor (NSCR, License No. R-83, Docket 50-128) Project stage: Other ML14092A4442014-04-10010 April 2014 Texas Engineering Experiment Station/Texas A&M University System, Nuclear Science Center - Approval of the Nuclear Science Center Senior Reactor Operator and Reactor Operator Requalification Program Project stage: Other ML14115A1632014-05-0505 May 2014 Texas Engineering Experiment Station/Texas A&M University System, Nuclear Science Center Review of the Emergency Preparedness Plan for License Renewal Project stage: Approval ML14168A1582014-06-19019 June 2014 Texas A&M University System/Texas Engineering Experiment Station Nuclear Science Center Transmittal Letter Request for Additional Information for the Physical Security Plan Review for License Renewal Project stage: RAI ML14192A2012014-07-15015 July 2014 Texas Engineering Experiment Station/Texas A&M University System - Request for Additional Information Review of the Fuel Pool Temperature on Fuel Temperature for License Renewal for the NSC Triga Reactor Project stage: RAI ML14293A4492014-11-0505 November 2014 Texas Engineering Experiment Station/Texas A&M University System - Request for Additional Information Regarding the Review Renewal for Facility Operating License R-83 for the Nuclear Science Center Triga Reactor Project stage: RAI ML15009A2792014-11-13013 November 2014 Response to U.S. NRC Request for Additional Information, Review of the Fuel Pool Temperature on Fuel Temperature for the License Renewal for the Nuclear Science Center Triga Reactor (TAC Me 1584), from the Texas A&M University System, Texas Project stage: Request ML14316A3932014-11-14014 November 2014 Texas A&M University System/Texas Engineering Experiment Station Nuclear Science Center Request for Additional Information for the Physical Security Plan Review for License Renewal (Cover Letter) Project stage: RAI ML15065A0682015-03-0202 March 2015 Texas A&M University - Response to Us NRC Request for Additional Information Regarding the Renewal of Facility Operating License No. R-83 for the Nuclear Science Center Triga Reactor Project stage: Request ML15092A9622015-04-15015 April 2015 Texas A&M University Training, Research, Isotopes, General Atomics Reactor Suspension of Experiments Under Technical Specification 3.5.3, Xenon and Iodine Monitoring and 3.6.4, Xenon Irradiation for Iodine Production Project stage: Other ML15125A2802015-05-0606 May 2015 Texas Engineering Experiment Station/Texas A&M University System - Request for Additional Information Regarding the Renewal of Facility Operating License No. R-83 for the Nuclear Science Center Triga Reactor Project stage: RAI ML15160A0232015-06-0505 June 2015 Texas A&M University - Response to U.S. NRC Request for Additional Information Regarding the Renewal of Facility Operating License No. R-83 Project stage: Request ML15187A2562015-06-30030 June 2015 Email to Correct Updated Proposed Tees TS from Jerry Newhouse 6.30.15 Project stage: Other NRC-2015-0210, General Notice: FRN Texas Engineering Experiment Station/Texas a & M University System - Environmental Assessment Renewal of Facility Operating License No. R-83 for the Nuclear Science Center Reactor2015-08-24024 August 2015 General Notice: FRN Texas Engineering Experiment Station/Texas a & M University System - Environmental Assessment Renewal of Facility Operating License No. R-83 for the Nuclear Science Center Reactor Project stage: Other ML1201900072015-08-24024 August 2015 General Notice: FRN Texas Engineering Experiment Station/Texas a & M University System - Environmental Assessment Renewal of Facility Operating License No. R-83 for the Nuclear Science Center Reactor Project stage: Other ML1201900042015-08-24024 August 2015 Texas Engineering Experiment Station/Texas A&M University System - Enviornmental Assessment Renewal of Facility Operating License No. R-83 Project stage: Other ML15289A5962015-09-30030 September 2015 NRC Form 669 Conversation Record Texas A&M University System, Texas Engineering Experiment Station, Nuclear Science Center Reactor Change to the Technical Specification 6.8.1 (NSCR, License No. R-83, Docket 50-128) Project stage: Other ML13030A4262015-10-0101 October 2015 Texas Engineering Experiment Station/Texas A&M University System - Technical Specifications Appendix a Renewed Facility Operating License R-83 Dated October 1, 2015 (Tac No. ME1584) Project stage: Other ML13030A4482015-10-0101 October 2015 Texas Engineering Experiment Station/Texas A&M University - Safety Evaluation Report for Renewed Facility Operating License (Tac No. ME1584) Project stage: Approval ML13030A4102015-10-0101 October 2015 Texas Engineering Experiment Station/Texas A&M University System - Issuance of Renewed Facility Operating License No. R-83 (Tac No. ME1584) Project stage: Approval ML13031A0312015-10-15015 October 2015 FRN: General Notice - Texas Engineering Experiment Station/Texas A&M University System - Notice of Issuance of Renewed Facility Operating License No. R-83 (Tac No. ME1584) Project stage: Approval 2014-11-13
[Table View] |
Text
OFFICIAL USE ONLY - SECURITY RELATED INFORMATION OFFICIAL USE ONLY - SECURITY RELATED INFORMATION June 19, 2014 Dr. Radek Skoda, Director Nuclear Science Center Texas Engineering Experiment Station 1095 Nuclear Science Road MS 3575 College Station, TX 77843
SUBJECT:
TEXAS ENGINEERING EXPERIMENT STATION/TEXAS A&M UNIVERSITY SYSTEM - REQUEST FOR ADDITIONAL INFORMATION RE: PHYSICAL SECURITY PLAN REVIEW FOR LICENSE RENEWAL (TAC NO. ME1584)
Dear Dr. Skoda:
The U.S. Nuclear Regulatory Commission (NRC) is continuing its review of your application for the renewal of Facility Operating License No. R-83, dated February 27, 2003 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML102920025), as supplemented, for the Texas Engineering Experiment Station/Texas A&M University System (TEES/TAMUS), Nuclear Science Center (NSC), TRIGA-type research reactor. The license renewal review includes an NRC staff review of your current TEES/TAMUS NSC Physical Security Plan, Revision No. 1, dated January 1995. We require additional information and clarification on questions that have arisen during our review. Please provide responses to the enclosed request for additional information (RAI) within 30 days from the date of this letter.
In accordance with 10 CFR 50.30(b), you must execute your response in a signed original document under oath or affirmation. Your response must be submitted in accordance with 10 CFR 50.4, Written communications. Information included in your response that is considered sensitive or proprietary, that you seek to have withheld from the public, must be marked in accordance with 10 CFR 2.390, Public inspections, exemptions, requests for withholding. Any information related to security should be submitted in accordance with 10 CFR 73.21, Protection of Safeguards Information: Performance requirements. Following receipt of the additional information, we will continue our evaluation of your renewal request.
NOTE: Enclosure Transmitted Herewith Contains Security-Related Information. When Separated from Enclosure, this Document is DECONTROLLED.
OFFICIAL USE ONLY - SECURITY RELATED INFORMATION OFFICIAL USE ONLY - SECURITY RELATED INFORMATION If you have any questions, or need additional time to respond to this request, contact me at (301) 415-0893 or by electronic mail at: Geoffrey.Wertz@nrc.gov.
Sincerely,
/RA/
Geoffrey A. Wertz, Project Manager Research and Test Reactors Licensing Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-128
Enclosure:
RAI cc w/o enclosure: See next page
Package: ML14170A912 Letter: ML14168A158 OUO-SRI RAI: ML14168A189 *concurrence via email
Texas A&M University Docket No. 50-128 cc:
Mayor, City of College Station P.O. Box Drawer 9960 College Station, TX 77840-3575 Governors Budget and Planning Office P.O. Box 13561 Austin, TX 78711 Texas A&M University System ATTN: Dr. Dimitris C. Lagoudas, Interim Facility Director Nuclear Science Center Texas Engineering Experiment Station 1095 Nuclear Science Road MS 3575 College Station, TX 77843 Radiation Program Officer Bureau of Radiation Control Dept. Of State Health Services Division for Regulatory Services 1100 West 49th Street, MC 2828 Austin, TX 78756-3189 Technical Advisor Office of Permitting, Remediation & Registration Texas Commission on Environmental Quality P.O. Box 13087, MS 122 Austin, TX 78711-3087 Test, Research and Training Reactor Newsletter 202 Nuclear Sciences Center University of Florida Gainesville, FL 32611