ML13207A235: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
 
(4 intermediate revisions by the same user not shown)
Line 3: Line 3:
| issue date = 09/19/2013
| issue date = 09/19/2013
| title = P. Daly Ltr Issuance of Amendment Relating to Upgraded Fuel Handling Building Crane for Zion Nuclear Power Station, Units 1 and 2 (TAC Nos. J00433 and J00434)
| title = P. Daly Ltr Issuance of Amendment Relating to Upgraded Fuel Handling Building Crane for Zion Nuclear Power Station, Units 1 and 2 (TAC Nos. J00433 and J00434)
| author name = Hickman J B
| author name = Hickman J
| author affiliation = NRC/FSME/DWMEP/DURLD/RDB
| author affiliation = NRC/FSME/DWMEP/DURLD/RDB
| addressee name = Daly P
| addressee name = Daly P
Line 15: Line 15:
| page count = 4
| page count = 4
}}
}}
=Text=
{{#Wiki_filter:September 19, 2013 Mr. Patrick Daly Senior Vice President and General Manager ZionSolutions LLC 101 Shiloh Blvd.
Zion, IL 60099-2797
==SUBJECT:==
ISSUANCE OF AMENDMENTS RELATING TO UPGRADED FUEL HANDLING BUILDING CRANE FOR ZION NUCLEAR POWER STATION, UNITS 1 AND 2 (TAC NOS. J00433 AND J00434)
==Dear Mr. Daly:==
By letters dated May 31, 2012, and October 25, 2012, as supplemented by letters dated December 20, 2012, January 17, 2013, February 21, 2013, April 4, 2013, and May 16, 2013, you submitted an application, pursuant to Section 50.90 of Title 10 of the Code of Federal Regulations (10 CFR), requesting a License Amendment for the decommissioning Zion Nuclear Power Station (ZNPS) Units 1 and 2.
The proposed amendment to Facility Operating License Nos. DPR-39 and DPR-48, requested approval of the upgraded Fuel Handling Building crane. As discussed in the enclosed Safety Evaluation, the crane upgrade conforms to the American Society of Mechanical Engineers (ASME) Rules for Construction of Overhead and Gantry Cranes (Top Running Bridge, Multiple Girder), NOG-1, 2004 Edition, as an acceptable means of meeting the criteria in NUREG-0554, Single-Failure-Proof Cranes for Nuclear Power Plants, and conforms to any applicable criteria listed in NUREG-0612, Control of Heavy Loads at Nuclear Power Plants: Resolution of Generic Technical Activity A-36, Appendix C.
This amendment revises the ZNPS Licenses. A copy of the related Safety Evaluation is enclosed. The Notice of Issuance will be included in the Commissions next biweekly Federal Register notice.
This amendment involves changes to the ZNPS License that change a requirement with respect to installation or use of a facility component located within the restricted area. The staff has determined that the amendment involves no significant increase in the amounts, and no significant change in the types, of any effluents that may be released offsite, and that there is no significant increase in individual or cumulative occupational radiation exposure. NRC has previously issued a proposed finding that the amendment involves no significant hazards consideration (77 FR 47123; August 7, 2012), and there has been no public comment on such finding. NRC staff has made a final determination that the proposed amendment does not involve a significant hazards consideration. Accordingly, the amendment meets the eligibility criteria for categorical exclusion set forth in 10 CFR 51.22(c)(9). Pursuant to 10 CFR 51.22(b),
no environmental impact statement or environmental assessment needs to be prepared in connection with the issuance of this amendment.
P. Daly                                  2 In accordance with 10 CFR 2.390 of the NRCs Rules of Practice for Domestic Licensing Proceedings and Issuance of Orders, a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records component of NRCs ADAMS. ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html.
Should you have any questions regarding this action please contact me at 301-415-3017 or john.hickman@nrc.gov.
Sincerely,
                                          /RA/
John B. Hickman, Project Manager Reactor Decommissioning Branch Decommissioning and Uranium Recovery Licensing Directorate Division of Waste Management and Environmental Protection Office of Federal and State Materials and Environmental Management Programs Docket Nos.: 50-295 and 50-304 License Nos.: DPR-39 and DPR-49
==Enclosures:==
: 1. Amendment to DPR-39
: 2. Amendment to DPR-48
: 3. Safety Evaluation cc: w/enclosures:
Zion Service List
P. Daly                                    2 In accordance with 10 CFR 2.390 of the NRCs Rules of Practice for Domestic Licensing Proceedings and Issuance of Orders, a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records component of NRCs ADAMS. ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html.
Should you have any questions regarding this action please contact me at 301-415-3017 or john.hickman@nrc.gov.
Sincerely,
                                              /RA/
John B. Hickman, Project Manager Reactor Decommissioning Branch Decommissioning and Uranium Recovery Licensing Directorate Division of Waste Management and Environmental Protection Office of Federal and State Materials and Environmental Management Programs Docket Nos.: 50-295 and 50-304 License Nos.: DPR-39 and DPR-49
==Enclosures:==
: 1. Amendment to DPR-39
: 2. Amendment to DPR-48
: 3. Safety Evaluation cc: w/enclosures:
Zion Service List Distribution:
ML13207A222 OFFICE    RDB              DWMEP/la    RDB              OGC              DWMEP/DD        RDB NAME      JHickman        SAchten      BWatson          HBenowitz        DPersinko        JHickman DATE      8/1/2013        7/31/2013    8/01/2013        9/17/2013        9/19/2013        9/19/2013 OFFICIAL RECORD COPY
Zion Nuclear Power Station, Units 1 and 2 Service List cc:
Patrick T. Daly                                    Mr. Kent McKenzie, Emergency Senior Vice President and General Manager            Management Coordinator ZionSolutions, LLC                                Lake County Emergency Management 101 Shiloh Blvd.                                    Agency Zion, IL 60099-2797                                1303 N. Milwaukee Avenue Libertyville, IL 60048-1308 Patrick Thurman, Esq.
VP Regulatory Affairs, Licensing and              Regional Administrator Document Control                                U.S. NRC, Region III ZionSolutions, LLC                                2443 Warrenville Road 101 Shiloh Blvd.                                  Lisle, IL 60532-4352 Zion, IL 60099-2797 John E. Matthews Gary Bouchard                                      Morgan, Lewis & Bockius LLP VP Engineering, Ops & Nuclear Security            1111 Pennsylvania Avenue, NW and Decommissioning Plant Manager                Washington, DC 20004 ZionSolutions, LLC 101 Shiloh Blvd.                                  Matias F. Travieso-Diaz Zion, IL 60099                                    Pillsbury Winthrop Shaw Pittman LLP 2300 N St., N.W.
Alan Parker                                        Washington, D.C. 20037 President Projects Group EnergySolutions                                    Tom Rielly, Executive Principal 800 Oak Ridge Turnpike, Ste. A-402                Vista 360 Oak Ridge, TN 37830                                649 Innsbruck Libertyville IL 60048 John Christian President of the Logistics, Processing and        Director Spent Fuel & Decommissioning Disposal Group                                      Strategy EnergySolutions                                    Exelon Generation Company, LLC 1750 Tysons Boulevard, Suite 1500                  4300 Winfield Road McLean, VA 22102                                  Warrenville, IL 60555 Thomas Magette                                    J. Bradley Fewell Senior VP Nuclear Regulatory Strategy              Associate General Counsel EnergySolutions                                    Exelon Corporation, LLC 6350 Stevens Forest Road, Ste. 2000                4300 Winfield Rd.
Columbia, MD 21046                                Warrenville, IL 60555 Russ Workman                                      Document Control Desk - Licensing General Counsel                                    Exelon Generation Company, LLC EnergySolutions                                    4300 Winfield Road 423 West 300 South, Suite 200                      Warrenville, IL 60555 Salt Lake City, UT 84101 Mayor of Zion Zion, IL 60099}}

Latest revision as of 15:31, 4 November 2019

P. Daly Ltr Issuance of Amendment Relating to Upgraded Fuel Handling Building Crane for Zion Nuclear Power Station, Units 1 and 2 (TAC Nos. J00433 and J00434)
ML13207A235
Person / Time
Site: Zion  File:ZionSolutions icon.png
Issue date: 09/19/2013
From: John Hickman
NRC/FSME/DWMEP/DURLD/RDB
To: Daly P
ZionSolutions
Shared Package
ML13207A222 List:
References
TAC J00433, TAC J00434
Download: ML13207A235 (4)


Text

September 19, 2013 Mr. Patrick Daly Senior Vice President and General Manager ZionSolutions LLC 101 Shiloh Blvd.

Zion, IL 60099-2797

SUBJECT:

ISSUANCE OF AMENDMENTS RELATING TO UPGRADED FUEL HANDLING BUILDING CRANE FOR ZION NUCLEAR POWER STATION, UNITS 1 AND 2 (TAC NOS. J00433 AND J00434)

Dear Mr. Daly:

By letters dated May 31, 2012, and October 25, 2012, as supplemented by letters dated December 20, 2012, January 17, 2013, February 21, 2013, April 4, 2013, and May 16, 2013, you submitted an application, pursuant to Section 50.90 of Title 10 of the Code of Federal Regulations (10 CFR), requesting a License Amendment for the decommissioning Zion Nuclear Power Station (ZNPS) Units 1 and 2.

The proposed amendment to Facility Operating License Nos. DPR-39 and DPR-48, requested approval of the upgraded Fuel Handling Building crane. As discussed in the enclosed Safety Evaluation, the crane upgrade conforms to the American Society of Mechanical Engineers (ASME) Rules for Construction of Overhead and Gantry Cranes (Top Running Bridge, Multiple Girder), NOG-1, 2004 Edition, as an acceptable means of meeting the criteria in NUREG-0554, Single-Failure-Proof Cranes for Nuclear Power Plants, and conforms to any applicable criteria listed in NUREG-0612, Control of Heavy Loads at Nuclear Power Plants: Resolution of Generic Technical Activity A-36, Appendix C.

This amendment revises the ZNPS Licenses. A copy of the related Safety Evaluation is enclosed. The Notice of Issuance will be included in the Commissions next biweekly Federal Register notice.

This amendment involves changes to the ZNPS License that change a requirement with respect to installation or use of a facility component located within the restricted area. The staff has determined that the amendment involves no significant increase in the amounts, and no significant change in the types, of any effluents that may be released offsite, and that there is no significant increase in individual or cumulative occupational radiation exposure. NRC has previously issued a proposed finding that the amendment involves no significant hazards consideration (77 FR 47123; August 7, 2012), and there has been no public comment on such finding. NRC staff has made a final determination that the proposed amendment does not involve a significant hazards consideration. Accordingly, the amendment meets the eligibility criteria for categorical exclusion set forth in 10 CFR 51.22(c)(9). Pursuant to 10 CFR 51.22(b),

no environmental impact statement or environmental assessment needs to be prepared in connection with the issuance of this amendment.

P. Daly 2 In accordance with 10 CFR 2.390 of the NRCs Rules of Practice for Domestic Licensing Proceedings and Issuance of Orders, a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records component of NRCs ADAMS. ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html.

Should you have any questions regarding this action please contact me at 301-415-3017 or john.hickman@nrc.gov.

Sincerely,

/RA/

John B. Hickman, Project Manager Reactor Decommissioning Branch Decommissioning and Uranium Recovery Licensing Directorate Division of Waste Management and Environmental Protection Office of Federal and State Materials and Environmental Management Programs Docket Nos.: 50-295 and 50-304 License Nos.: DPR-39 and DPR-49

Enclosures:

1. Amendment to DPR-39
2. Amendment to DPR-48
3. Safety Evaluation cc: w/enclosures:

Zion Service List

P. Daly 2 In accordance with 10 CFR 2.390 of the NRCs Rules of Practice for Domestic Licensing Proceedings and Issuance of Orders, a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records component of NRCs ADAMS. ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html.

Should you have any questions regarding this action please contact me at 301-415-3017 or john.hickman@nrc.gov.

Sincerely,

/RA/

John B. Hickman, Project Manager Reactor Decommissioning Branch Decommissioning and Uranium Recovery Licensing Directorate Division of Waste Management and Environmental Protection Office of Federal and State Materials and Environmental Management Programs Docket Nos.: 50-295 and 50-304 License Nos.: DPR-39 and DPR-49

Enclosures:

1. Amendment to DPR-39
2. Amendment to DPR-48
3. Safety Evaluation cc: w/enclosures:

Zion Service List Distribution:

ML13207A222 OFFICE RDB DWMEP/la RDB OGC DWMEP/DD RDB NAME JHickman SAchten BWatson HBenowitz DPersinko JHickman DATE 8/1/2013 7/31/2013 8/01/2013 9/17/2013 9/19/2013 9/19/2013 OFFICIAL RECORD COPY

Zion Nuclear Power Station, Units 1 and 2 Service List cc:

Patrick T. Daly Mr. Kent McKenzie, Emergency Senior Vice President and General Manager Management Coordinator ZionSolutions, LLC Lake County Emergency Management 101 Shiloh Blvd. Agency Zion, IL 60099-2797 1303 N. Milwaukee Avenue Libertyville, IL 60048-1308 Patrick Thurman, Esq.

VP Regulatory Affairs, Licensing and Regional Administrator Document Control U.S. NRC, Region III ZionSolutions, LLC 2443 Warrenville Road 101 Shiloh Blvd. Lisle, IL 60532-4352 Zion, IL 60099-2797 John E. Matthews Gary Bouchard Morgan, Lewis & Bockius LLP VP Engineering, Ops & Nuclear Security 1111 Pennsylvania Avenue, NW and Decommissioning Plant Manager Washington, DC 20004 ZionSolutions, LLC 101 Shiloh Blvd. Matias F. Travieso-Diaz Zion, IL 60099 Pillsbury Winthrop Shaw Pittman LLP 2300 N St., N.W.

Alan Parker Washington, D.C. 20037 President Projects Group EnergySolutions Tom Rielly, Executive Principal 800 Oak Ridge Turnpike, Ste. A-402 Vista 360 Oak Ridge, TN 37830 649 Innsbruck Libertyville IL 60048 John Christian President of the Logistics, Processing and Director Spent Fuel & Decommissioning Disposal Group Strategy EnergySolutions Exelon Generation Company, LLC 1750 Tysons Boulevard, Suite 1500 4300 Winfield Road McLean, VA 22102 Warrenville, IL 60555 Thomas Magette J. Bradley Fewell Senior VP Nuclear Regulatory Strategy Associate General Counsel EnergySolutions Exelon Corporation, LLC 6350 Stevens Forest Road, Ste. 2000 4300 Winfield Rd.

Columbia, MD 21046 Warrenville, IL 60555 Russ Workman Document Control Desk - Licensing General Counsel Exelon Generation Company, LLC EnergySolutions 4300 Winfield Road 423 West 300 South, Suite 200 Warrenville, IL 60555 Salt Lake City, UT 84101 Mayor of Zion Zion, IL 60099