ML17209A554: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
 
(8 intermediate revisions by the same user not shown)
Line 2: Line 2:
| number = ML17209A554
| number = ML17209A554
| issue date = 07/28/2017
| issue date = 07/28/2017
| title = Watts Bar, Unit 1 - Cycle 14 Steam Generator Tube Inspection Report
| title = Cycle 14 Steam Generator Tube Inspection Report
| author name = Simmons P
| author name = Simmons P
| author affiliation = Tennessee Valley Authority
| author affiliation = Tennessee Valley Authority
Line 13: Line 13:
| document type = Letter, Report, Miscellaneous
| document type = Letter, Report, Miscellaneous
| page count = 22
| page count = 22
| revision = 0
}}
}}
=Text=
{{#Wiki_filter:Tennessee Valley Authority, Post Office Box 2000, Spring City, Tennessee 37381 July 28,2017 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Watts Bar Nuclear Plant, Unit 1 Facility Operating License No. NPF-90 NRC Docket No. 50-390
==Subject:==
Watts Bar Nuclear Plant (WBN) Unit 1 - Cycle 14 Steam Generator Tube lnspection Report ln accordance with the requirements of WBN Technical Specification (TS) 5.9.9, "Steam Generator Tube lnspection Report," the Enclosure provides the 180 Day Steam Generator lnspection Report for Unit 1 Cycle 14. This report is required to be submitted within 180 days after the initial entry into MODE 4 following the completion of an inspection performed in accordance with TS 5.7.2.12, "Steam Generator (SG) Program." The report provides the complete results of the tube inspections.
There are no regulatory commitments in this submittal. Please direct any questions concerning this matter to Kasey Decker, WBN Site Licensing, at 423-365-3173.
Respectfully, Pau! Simmons Site Vice President Watts Bar Nuclear Plant
==Enclosure:==
Watts Bar U1R14 180 Day Steam GeneratorTube Inspection Report cc: See Page 2
U.S. Nuclear Regulatory Commission Page 2 July 28,2017 Enclosures cc (Enclosures):
NRC Regional Administrator - Region ll NRC Project Manager - Watts Bar Nuclear Plant, Unit 1 NRC Senior Resident lnspector - Watts Bar Nuclear Plant, Unit 1
Enclosure Watts Bar UlR14 180 Day Steam Generator Tube lnspection Report
WTSTTNGHOUSE NON-PnoprueTARY CIess 3 SCr-SGMP-17-20                                          June 2017 Revision 0 Watts Bar U1R14 180 Day Steam Generator TUbe Inspection Report
WESTINGHOUSE NON-PROPRIETARY CLASS                3 SCr-SGMP-17-20 Revision 0 Waffs Bar U1R14 180 Day Steam Generator Tube Inspection Report Prepared for:
Tennessee Valley Authority Author's Name:                              Signature lDate                              For Pages William R. LaMantia                          *EI ec tron i caII v A p pro ved                All SG Management Programs Verifier's Name:                            Signature lDate                              For Pages Jesse S. Baron                              *EI ectron i c aII v A p pro ved                All SG Management Programs Manager's Name:                            Signature I Date                            For Pages David P. Lytle, Manager                      *Electronicallv A o oroved                    All SG Management Programs Revierverts Name:                          Signnture I Date                            For Fageo Jercmyl[/. Mayo TYA SGPrograrnManager Reviewer'sNnmel                            Signature  /
Tarnmy C. $ears TYA Watts Bar SG Progmm O$mer Rtvlewgr'r Nnnrtr                          Sign*ffir* / Date                          For Pages DaniclP, Folsom TYA NDHLevel      III
                                            -"&\
* Electronically Approved Records are Authcnticeted in the Elcafronic Document Menagcmeat System 02017 Westinghouse Electric Company          LtC Alt Rights Reserved SG-SGMP-17-20                                                                            June 2017 Revision 0                                                                              Page 2 of 19
Record of Revisions Revision    Date Description June 0a            Preliminary draft for Tennessee Valley Authority review and corrment.
2017 See 0            Original Issue EMDS SG-SGMP-17-20                                                                            June 2017 Revision 0                                                                              Page 3 of 19
Table of Contents 2.0  180 Day Steam Generator Tube lnspection    Report                                                      ..........6
: a.        The Scope of the Inspections Performed on Each  SG.............                        ...............6
: b.        Active Degradation Mechanisms    Found......                                  ........................6
: c.        Nondestructive Examination (NDE) Techniques Used for Each Degradation Mechanism..........6
: d.        Location, Orientation (if Linear), and Measured Sizes (if Available) of Service lnduced Indications.                                                                        ..................7
: e.        Number of Tubes Plugged During the Inspection Outage for Each Active Degradation Mechanism                                                                          ................18
: f.        Total Number and Percentage of Tubes Plugged to  Date                        ..................... 19 o
D.        The Results of Condition Monitoring, Including the Results of Tube Pulls and In-Situ Testinglg
: h.        The Effective Plugging Percentage for All Plugging in Each SG..............          .............. 19 List of Tables and Figures Figure  l-l: Tube Support Arrangement for Watts Bar Unit I Model 68AXP Replacement Steam Generators .5 Table  2-l:  Watts Bar UlRl4 Steam Generator Eddy Current Inspection  Scope.........          .....................6 Table2-2: Number of lndications Detected for Each Degradation    Mechanism                              ............6 Table 2-3: NDE Techniques for Each Existing or Potential Degradation    Mechanism.............                ........7 Table 24: Watts Bar UlRl4 U-bend Support Stnrcture Wear Indications - All SGs      ............            ..........7 Table 2-5: Watts Bar UlR14 Horizontal Tube Support Grid Wear Indications - SG      1...........              .........9 Table2-9: Number of Tubes Plugged for Each Degradation      Mechanism                          ...................18 SG-SGMP-17-20                                                                                            Jnne 2017 Revision 0                                                                                            Page 4    of  19
1.0      Introduction Inspections of the replacement steam generators (SGs) were perforrned during the Watts Bar Unit 1 (WBNI) spring 2017 refueling outage designated as (UlRl4). These inspections included eddy current test.g of the SG tubing as well as primary and secondary side cleanings and visual inspections. This report documents the "Watts Bar UlRl4 180-Day Steam Generator Tube lnspection Report" as required by the WBN1 Technical Specifications.
The original steam generators at WBNI were replaced in 2006 with Westinghouse Model 68AXP SGs which have thermally treated Alloy 690 tubing. The UlRl4 inspection was the third in-service inspection of the replacement SGs. Prior to the UlRl4 inspection, the replacement SGs had operated for seven (7) fuel cycles since replacement. The replacement SGs had operated for tbree (3) fuel cycles since the previous inspection at UlRl l. Figure l-l below provides the arrangement and location designation of the tube support structures for the WBN1 SGs.
AXIAL fLott ilL.-,- C0LD SIDI
                                                                      );rr    RECIRCULATING TNTRANCT CROSS TLOW HOT SIDE RECIRCULATINO ENTRANCT CROSS TLOW Figure 1-1: Tube Support Arrangement for Watts Bar Unit          I Model68AXP    Replacement Steam Generators Notes: VS : Vertical  Strap DS : Diagonal Strap HTS/CTS : Hot/Cold Tubesheet (designates top of tubesheet)
HTE/CTE : Hot/Cold Tube End Horizontal supports are a lattice grid design SG-SGMP-17-20                                                                                    Jtrne 2017 Revision 0                                                                                      Page 5 of 19
2.0      180 Day Steam Generator Tube Inspection Report In accordance with WBNI Technical Specification Section 5.7.2.12, "Steam Generator Program", and Technical Specification Section 5.9.9, "Steam Generator Tube Inspection Report", this report documents the scope and results of the UlR14 SG inspections. There are eight specific reporting requirements associated with the Technical Specification. Each lettered reporting requirement listed below is followed with the associated infonnation based on the inspections performed during U1R14.
: a. The Scope of the Inspections Performed on Each SG The  UlRl4 outage included a combination of bobbin and array coil inspections of 100% of the full length in all in-service tubes except for tubes in Rows I through 4. Tube Rows I through 4 were inspected to the frst support with the combination bobbin and array coil from both the hot leg tube end (HTE) and the cold leg tube end (CTE). The remainder of the tube length in Rows I through 4 were inspected with a singular bobbin probe due to dimensional clearance restrictions in the U-bend region. As a result, the inspection included all tubes with prior indications of degradation and all tubes not inspected during the previous SG in-service inspection. The table below summarizes the number and type of eddy current examinations performed during UlR14.
Table 2-1: Watts Bar U1R14 Steam Generator Eddy Current Inspection Scope Eddy Current Exam TVpe        sGl      sG2    sG3    sG4        Total 0.610 tIL Bobbin & Array VS3-HTE  5,125  5,123    5,121  5,114    20,483 0.610 CL Bobbin & Array VS3-CTE    5,125  5,123    5,121  5,114    20,483 0.590 HLICL Bobbin (U-bend Region)  t27      t27    t27      t27      s08 In addition to the eddy current inspections, visual inspections were also performed on both the primary and secondary sides. Primary side visual inspections included all previously installed tube plugs, the channel head bowl cladding, and the divider plate. Secondary side visual inspections were performed at the top of the tubesheet for the detection of foreign objects, assessment of hard deposit buildup in the tube bundle interior 'kidney region' and for determining the effectiveness of the tubesheet cleaning performed in all four SGs.
: b. Active Degradation Mechanisms Found Volumetric wear was the only degradation mechanism detected during the UlRl4 inspection. All of the wear indications detected were located at either U-bend or horizontal tube support structures. Table 2-2 below shows the number of indications reported during the UlR14 inspection.
Table2-22 Number of Indications Detected for Each Degradation Mechanism Degradation Mechanism          scl1      sG12    sG13      SGl4      Total U-bend Support Stmcnre Wear          l3        lt      23        t2        59 Horizontal Tube Support Grid Wear    74        139      83      t23        419
: c. Nondestructive Examination (NDE) Techniques Used for Each Degradation Mechanism Table 2-3 below provides the NDE techniques that were used for the detection                  of each degradation mechanism that was considered as existing or potential for the    UlRl4    inspection.
SG-SGMP-17-20                                                                                  Jtrne 2017 Revision 0                                                                                      Page 6 of 19
Table 2-3: I\DE Techniques for Each Existing or Potential Degradation Mechanism Degradation Mechanism    Detection Technique            EPRI ETSS Bobbin            96004.1, Revision l3 Array              I 1956. l, Revision 2 U-Bend Array              11956.2, Revision 2 Support Stmcture Wear Array              I 1956.3, Revision 2 Array              11956.4. Revision2 Bobbin            96004.1, Revision l3 Array              I 1956.1, Revision 2 Horizontal Array              11956.2,  Revision2 Tube Support Grid Wear Array              I1956.3, Revision2 Array              11956.4. Revision2 Bobbin            27091.2, Revision 2 Array              I 1956.1, Revision 2 Foreign Object Wear            Array              11956.2, Revision 2 Array              I1956.3, Revision 2 Array              11956.4. Revision2 Tube-to-Tube Wear              Bobbin            96010.1, RevisionT
: d. Location, Orientation (if Linear), and Measured Sizes (if Available) of Service Induced Indications Table 2-4 through 2-8 below provides a listing of all service-induced indications reported during the UlRl4 inspection including the estimated depths from the bobbin coil.
Table 24: lVatts Bar U1R14 U-bend Support Structure Wear fndications            - All SGs SG    Row    Col    Locn    Inchl    Ind  YuTW              Characterization                Resolution I      53      74    VS4        l. t5 PCT    l5        U-bend Support Stnrcnre Wear      Remain In-Service I      58      47    VS3        1.29  PCT    l6        U-bend Support Structure Wear      Remain In-Service I      58      47    VS3      -0.96  PCT    l6        U-bend Support Structure Wear      Remain In-Service I      66      65    V54        0.86  PCT    r9        U-bend Support Structure Wear      Remain In-Service I      77      56    VS3      -0.9r  PCT    l8        U-bend Support Structure Wear      Remain In-Service I      77      82    VS3        t.t2  PCT    t7        U-bend Support Stnrcture Wear      Remain In-Senrice I      82      83    VS4        I.0r  PCT    t8        U-bend Support Structure Wear      Remain In-Service I      95      58    VS2      -0.61    PCT    l5        U-bend Support Structure Wear      Remain In-Service I    105      68    DS2      0.62    PCT    2t        U-bend Support Stnrcture Wear      Remain In-Service I    105      68    VS2      -0.03    PCT    l9        U-bend Support Stnrcture Wear      Remain In-Service I    105      68    VS2      -0.72  PCT    l8        U-bend Support Structure Wear      Remain In-Service I    r05      68    VS4        1.03  PCT    l7        U-bend Support Stnrcture Wear      Remain In-Service I    105      68    DS2      -0.23  PCT    l5        U-bend Support Structure Wear      Remain In-Service 2      65      98    VS2        t.24  PCT    t7        U-bend Support Structure Wear      Remain In-Service 2      67      96    VS2        1.05  PCT    t4        U-bend Support Structure Wear      Remain In-Service 2      75      54    VS4      0.86    PCT    22        U-bend Support Structure Wear      Remain In-Service 2      90      67    VS4      -0.76  PCT    l8        U-bend Support Stnrcture Wear      Remain In-Service 2      90      67    VS2      -0.85    PCT    t2        U-bend Support Stnrcture Wear      Remain In-Service 2      9l      58    vs2        0.8    PCT    20        U-bend Support Stnrcture Wear      Remain In-Service 2      96      63    VS3      -0.64  PCT    22        U-bend Support Stnrcture Wear      Remain In-Service 2      99      s8    VS4        0.8    PCT    l8        U-bend Support Stmcture Wear      Remain In-Service 2    r00      63    VS2      -0.75  PCT    24        U-bend Support Stnrcture Wear      Remain In-Service 2    100      63    VS2      0.55    PCT    l8        U-bend Support Stnrcture Wear      Remain In-Service 2    l0l      52    vst      -0.93    PCT    t3        U-bend Support Stnrcture Wear      Remain In-Service SG-SGMP-17-20                                                                                          June 2017 Revision 0                                                                                            Page 7 of 19
SG    Row Col Locn Inchl  Ind o/oTW      Characterization          Resolution  '
3      24 69  DS4  -0.03  PCT  23  U-bend Support Stnrcture Wear Remain In-Service 3      43 78  VS3      1.2 PCT  t6  U-bend Support Stnrcture Wear Remain In-Service 3      50 85  vs3  -0.38  PCT  20  U-bend Support Structure Wear Remain In-Service 3      53 82  VS3  -0.12  PCT  t9  U-bend Support Structure Wear Remain In-Service 3      63 82  VS3    1.35  PCT  t7  U-bend Support Stnrcture Wear Remain In-Service 3      &  8l  VS3    1.82  PCT  l7  U-bend Support Stnrcture Wear Remain In-Service 3      8l 56  VS4    0.89  PCT  27  U-bend Support Structure Wear Remain In-Service 3      82 43  VS2  -0.95  PCT  l8  U-bend Support Structure Wear Remain In-Service 3      96 67  VS2  -0.78  PCT  l6  U-bend Support Structure Wear Remain In-Service 3      97 56  VS3    0.74  PCT  20  U-bend Support Structure Wear Remain In-Service 3      97 56  VS3    t.2l  PCT  l9  U-bend Support Stnrcture Wear Remain In-Service 3      97 @  DS3  -0.83  PCT  t9  U-bend Support Structure Wear Remain In-Service 3      98 7l  VS4    0.t3  PCT  20  U-bend Support Stnrcture Wear Remain In-Service 3      99 50  DS3    0.82  PCT  l8  U-bend Support Structure Wear Remain In-Service 3      99 58  VS4    0.96  PCT  2t  U-bend Support Structure Wear Remain In-Service 3      99 s8  V34    0.03  PCT  l7  U-bend Support Structure Wear Remain In-Service 3    r00 55  VS2  -0.75  PCT  20  U-bend Support Stnrcture Wear Remain In-Service 3    100 63  DS3    0.8  PCT  t7  U-bend Support Structure Wear Remain In-Service 3    100 67  DS3  0.7 5  PCT  l8  U-bend Support Stnrcture Wear Remain In-Service 3    r0l 58  DS2    -0.8  PCT  2t  U-bend Support Stnrcture Wear Remain In-Service 3    l0l 58  VS4  0.84  PCT  t9  U-bend Support Structure Wear Remain In-Service 3    l0l 58  VS3  -0.31  PCT  t7  U-bend Support Structure Wear Remain In-Service 3    102 73  VSI  -0.91  PCT  l9  U-bend Support Stmcture Wear  Remain In-Service 4      92 8l  VS2    0.9  PCT  23  U-bend Support Structure Wear Remain In-Service 4      93 70  VS2  0.92  PCT  19  U-bend Support Stnrcture Wear Remain In-Service 4      93 70  VS2  0.06  PCT  l8  U-bend Support Stnrcture Wear Remain In-Service 4      93 70  VS2  -0.82  PCT  l8  U-bend Support Structure Wear Remain In-Service 4      93 80  vs2  0.96  PCT  2t  U-bend Support Structure Wear Remain In-Service 4      93 80  vs2    0.2  PCT  t7  U-bend Support Stnrcture Wear Remain In-Service 4      96 83  DS2  -0.83  PCT  20  U-bend Support Structure Wear Remain In-Service 4      97 72  VS3  -0.24  PCT  l8  U-bend Support Stmcture Wear  Remain In-Service 4      98 47  VS2  0.82  PCT  l5  U-bend Support Structure Wear Remain In-Service 4    l0l 70  VS3  0.61  PCT  t9  U-bend Support Structure Wear Remain In-Service 4    102 57  VS3    t.t4 PCT  22  U-bend Support Stnrcture Wear Remain In-Service 4    102 57  DS2  -0.76  PCT  2t  U-bend Support Structure Wear Remain In-Service SG-SGMP-17-20                                                              June 2017 Revision 0                                                                  Page 8 of 19
Table 2-5: Watts Bar U1R14 Ilorizontal Tube Support Grid Wear Indications -  SG  I SG    Row    Col    Locn  Inchl    Ind  (%rw    Characterization      Resolution I      I      48    H04      1.06  PCT    l8  Horizontal Grid Wear Remain In-Service I      I      48    H07      0. l9 PCT    l7  Horizontal Grid Wear Remain In-Service I      I    I l6  c04    -0.88  PCT    l8  Horizontal Grid Wear Remain In-Service 1      7      64    H09      0.66  PCT    t9  Horizontal Grid Wear Remain In-Service I      7      88    H06      -0.97  PCT    22  Horizontal Grid Wear Remain In-Service I      7    102    H08      0.63  PCT    l8  Horizontal Grid Wear Remain In-Service I      8      99    H09      1.06  PCT    t9  Horizontal Grid Wear Remain In-Service I      8    tzt    c05      -0.67  PCT    l7  Horizontal Grid Wear Remain In-Service I      9    100    cl0    -0.87  PCT    t9  Horizontal Grid Wear Remain In-Service I      9    100    cll      0.76  PCT    l8  Horizontal Grid Wear Remain In-Service I      9    104    H07      -0.92  PCT    22  Horizontal Grid Wear Remain In-Service I    l8    103    H07    -0.92  PCT    20  Horizontal Grid Wear Remain In-Service I    23      84    clr      0.78  PCT    l9  Horizontal Grid Wear Remain In-Service I    26    t23    c06      -0.7  PCT    r9  Horizontal Grid Wear Remain In-Service I    27    124    c06    -0.84  PCT    20  Horizontal Grid Wear Remain In-Service I    28      45    clr      0.67  PCT    t9  Horizontal Grid Wear Remain In-Service I    29    t24    c06      0.77  PCT    20  Horizontal Grid Wear Remain In-Service I    29    t24    c0s      -0.9  PCT    t7  Horizontal Grid Wear Remain In-Service I    34    t23    c05    -0.87  PCT    t9  Horizontal Grid Wear Remain In-Service I    59    n2    c06    -0.67  PCT    t7  Horizontal Grid Wear Remain In-Service I    60    ll5    c0s    -0.67  PCT    l8  Horizontal Grid Wear Remain In-Service I    67    tt2    c06      0.83  PCT    t9  Horizontal Grid Wear Remain In-Service I    68    lll    c06      0.75  PCT    l8  Horizontal Grid Wear Remain In-Service I    7l    ll0    c06      0.81  PCT    t9  Horizontal Grid Wear Remain In-Service I    76    t07    c06      0.62  PCT    22    Horizontal Grid Wear Remain In-Service I    77    106    c06      0.72  PCT    l8  Horizontal Grid Wear Remain In-Service I    79    104    c03    -0,84  PCT    t7  Horizontal Grid Wear Remain In-Service I    82    103    c04    -0.7 4  PCT    l5  Horizontal Grid Wear Remain In-Service I    83      26    c03      0.73  PCT    l9  Horizontal Grid Wear Remain In-Service I    83    r02    c03    -0.76  PCT    l9  Horizontal Grid Wear Remain In-Service I    83    t02    c06      0.67  PCT    l7  Horizontal Grid Wear Remain In-Service I    84      99    c04      0.75  PCT    22    Horizontal Grid Wear Remain In-Service I    84      99    c03    -0.76  PCT    l9  Horizontal Grid Wear Remain In-Service I    84      99    c07        I  PCT    l8  Horizontal Grid Wear Remain In-Service I    85      30    c03      0.73  PCT    2l    Horizontal Grid Wear Remain In-Service I    85      94    c03          I  PCT    l8  Horizontal Grid Wear Remain In-Service I    85      98    c04      0.81  PCT    l8  Horizontal Grid Wear Remain In-Service I    85    100    c03    -0.79  PCT    27    Horizontal Grid Wear Remain In-Service I    86      97    c04      0.56  PCT    t7  Horizontal Grid Wear Remain In-Service I    86      99    c03      -0.9  PCT    l8  Horizontal Grid Wear Remain In-Service 1    87      30    c02    0.73  PCT    2l    Horizontal Grid Wear Remain In-Service I    87      96    c04    -0.87  PCT    l9  Horizontal Grid Wear Remain In-Service 1    87      98    c03      0.76  PCT    2l    Horizontal Grid Wear Remain In-Service I    88      3l    c03      0.78  PCT    t7  Horizontal Grid Wear Remain In-Service I    88      95    c03    -0.87  PCT    22    Horizontal Grid Wear Remain In-Service I    88      97    c03      0.78  PCT    2t    Horizontal Grid Wear Remain In-Service SG-SGMP-17-20                                                                              June 2017 Revision 0                                                                                Page 9 of 19
I  89  94 c04  0.73  PCT l8 Horizontal Grid Wear Remain In-Service I  89  96 c03 -0.t9  PCT 33 Horizontal Grid Wear Remain In-Service I  90  93 c03 -0.75  PCT 20 Horizontal Grid Wear Remain In-Service I  90  95 c04  0.59  PCT 22 Horizontal Grid Wear Remain In-Service I  90  95 c03 -0.78  PCT 2t Horizontal Grid Wear Remain In-Service I  9l  90 c04 -0.98  PCT t9 Horizontal Grid Wear Remain In-Service I  9l  92 c03  -0.9  PCT l9 Horizontal Grid Wear Remain In-Service I  9l  94 c06  0.64  PCT 20 Horizontal Grid Wear Remain In-Service I  92  9l c03  -0.9  PCT l8 Horizontal Grid Wear Remain In-Service I  92  93 c03 -0.79  PCT 24 Horizontal Grid Wear Remain In-Service I  95  88 c03  0.7 5 PCT 22 Horizontal Grid Wear Remain In-Service I  96  89 c03 -0.93  PCT l8 Horizontal Grid Wear Remain In-Service I  97  84 c07  0.78  PCT 2t Horizontal Grid Wear Remain In-Service I  97  84 c03  -0.79 PCT 20 Horizontal Grid Wear Remain In-Service I  98  85 c05 -0.92  PCT 22 Horizontal Grid Wear Remain In-Service I  98  85 c03  0.73  PCT 20 Horizontal Grid Wear Remain In-Service I  100 83 c05 -0.95  PCT 23 Horizontal Grid Wear Remain In-Service I  100 83 c03  0.75  PCT 22 Horizontal Grid Wear Remain In-Service I  t0l 66 c03  0.78  PCT l7 Horizontal Grid Wear Remain In-Service I  l0l 78 c03 -0.95  PCT 20 Horizontal Grid Wear Remain In-Service I  102 7l c03 -0.8 r PCT t7 Horizontal Grid Wear Remain In-Service 1  102 7l c04    I  PCT l6 Horizontal Grid Wear Remain In-Service I  102 79 c03  0.73  PCT 23 Horizontal Grid Wear Remain In-Service I  103 54 c03  0.9s  PCT l8 Horizontal Grid Wear Remain In-Service I  103 74 c03  0.95  PCT l8 Horizontal Grid Wear Remain In-Service I  104 63 c03  0.78  PCT t8 Horizontal Grid Wear Remain In-Service I  105 64 c05  -0.92 PCT 22 Horizontal Grid Wear Remain In-Service I  105 64 c03  0.7 5 PCT 20 Horizontal Grid Wear Remain In-Service SG-SGMP-17-20                                                        June 2017 Revision 0                                                            Page l0 of 19
aDte 2{:
Table      wa Bar U1R14 Horizontal z-oz Watts              o  n  u Suooort Grid Wear Tube                  ear Inorcauons Indications -
                                                                                        - SG 2 SG    Row      Col  Locn Inchl    Ind  o/oTW  Characterization          Resolution 2      I      42  H04    -0.8    PCT    t6  Horizontal Grid Wear    Remain In-Service 2      I      44  H08  -0.91    PCT    t6  Horizontal Grid Wear    Remain In-Service 2      I      44  H04  -0.86    PCT    l3  Horizontal Grid Wear    Remain In-Service 2      I      48  H04    0.91    PCT    t7  Horizontal Grid Wear    Remain In-Service 2      I      70  H05  -0.95    PCT    l6  Horizontal Grid Wear    Remain In-Service 2      I      74  H04    -0.6    PCT    l8  Horizontal Grid Wear    Remain In-Service 2      2      31  H06  -0.99    PCT    l9  Horizontal Grid Wear    Remain In-Service
          )      2      4t  H07  -0.94    PCT    t7  Horizontal Grid Wear    Remain In-Service 2      2      53  H0s  -0.72    PCT    l6  Horizontal Grid Wear    Remain In-Service 2      2      69  H04  -0.94    PCT    t7  Horizontal Grid Wear    Remain In-Service
          )
L      2      73  H04  -0.88    PCT    l6  Horizontal Grid Wear    Remain In-Service 2      2      l0l  H06    0.86    PCT    l7  Horizontal Grid Wear    Remain In-Service 2      6        I  c03    0.81    PCT    l7  Horizontal Grid Wear    Remain In-Senrice 2      8        I  c03    0.56    PCT    l8  Horizontal Grid Wear    Remain In-Service 2      8      77  H08  -0.98    PCT    25  Horizontal Grid Wear    Remain In-Service 2      8      77  H07    l.0l  PCT    2t  Horizontal Grid Wear    Remain In-Service 2      8      t27  c04    0.82    PCT    22  Horizontal Grid Wear    Remain In-Service 2      8      127  c03    0.76    PCT    2t  Horizontal Grid Wear    Remain In-Service 2    t0      t27  c03    0.75    PCT    2t  Horizontal Grid Wear    Remain In-Service 2    t4      t23  c03    0.92    PCT    t7  Horizontal Grid Wear    Remain In-Service 2    l8      73  H07    r.04  PCT    l9  Horizontal Grid Wear    Remain In-Service 2    t9      124  c05  -0.93    PCT    l8  Horizontal Grid Wear    Remain In-Service 2    l9      t24  c03  0,76    PCT    t7  Horizontal Grid Wear    Remain In-Service 2    t9      126  c03  0.79    PCT    t7  Horizontal Grid Wear    Remain In-Service 2    20      t23  c03  0.86    PCT    l8  Horizontal Grid Wear    Remain In-Service 2    2t      t22  c09    1.04  PCT    20  Horizontal Grid Wear    Remain In-Service 2    22      123  c03  0.73    PCT    30  Horizontal Grid Wear    Remain In-Service 2    22      t23    c07  0.76    PCT    23  Horizontal Grid Wear    Remain In-Service 2    22      r23    c07  -0.92    PCT    23  Horizontal Grid Wear    Remain In-Service 2    22      t23  c05  0.64    PCT    l8  Horizontal Grid Wear    Remain In-Service 2    22      123  c06    1.07  PCT    l8  Horizontal Grid Wear    Remain In-Service 2    22      t25  c03    0.7    PCT    18  Horizontal Grid Wear    Remain In-Service 2    22      t25  c06  0.73    PCT    r8  Horizontal Grid Wear    Remain In-Service 2    23      44    ct2  0.67    PCT    20  Horizontal Grid Wear    Remain In-Service 2    23      48    ct2 -0.84    PCT    t7  Horizontal Grid Wear    Remain In-Service 2    23      t22  c03  0.76    PCT    22  Horizontal Grid Wear    Remain In-Service
          )    25      28  ct2  -0.79    PCT    l3  Horizontal Grid Wear    Remain In-Service 2    25      122  c03  0.76    PCT    23  Horizontal Grid Wear    Remain In-Service 2    26      t23  c03  0.6s    PCT    2t  Horizontal Grid Wear    Remain In-Service 2    26      123  CM    0.@      PCT    l9  Horizontal Grid Wear    Remain In-Service 2    26      t23  c03  -0.9s    PCT    l8  Horizontal Grid Wear    Remain In-Service 2    26      t25  c03    0.t    PCT    l8  Horizontal Grid Wear    Remain In-Service 2    27      4    c06    1.04    PCT    l5  Horizontal Grid Wear    Remain In-Service
          )    27      t24  c03  0.8 r    PCT    2t  Horizontal Grid Wear    Remain In-Service 2    27      124  c05  -0.98    PCT    t9  Horizontal Grid Wear    Remain In-Service
          )    28      ll9  c06  -0.82    PCT    2t  Horizontal Grid Wear    Remain In-Service 2    28      t23  c03  0.78    PCT    26  Horizontal Grid Wear    Remain In-Service SG-SGMP-17-20                                                                              June 2017 Revision 0                                                                                Page 11 of 19
SG  Row Col  Locn Inchl  Ind YrTW  Characterization      Resolution 2  30    7  c06    0.76  PCT  t6 Horizontal Grid Wear Remain In-Service 2  30  123  c06    0.84  PCT  27  Horizontal Grid Wear Remain In-Service 2  30  t23  c07  -0.86  PCT  27  Horizontal Grid Wear Remain In-Service 2  30  t23  c03    0.73  PCT  26  Horizontal Grid Wear Remain In-Service 2  30  t23  c05  -0.89  PCT  23  Horizontal Grid Wear Remain In-Service 2  30  123  c06  -0.84  PCT  20  Horizontal Grid Wear Remain In-Service 2  30 123  c04    0.65  PCT  l8 Horizontal Grid Wear Remain In-Service 2  3r  54    ct2    1.03 PCT  22  Horizontal Grid Wear Remain In-Service 2  32 t2t  c03    0.73  PCT  t9 Horizontal Grid Wear Remain In-Service 2  32 t2t  c05  -0.93  PCT  l8 Horizontal Grid Wear Remain In-Service 2  33 t22  c03    -0.9  PCT  l9 Horizontal Grid Wear Remain In-Service 2  33 122  c04    0.73  PCT  l8 Horizontal Grid Wear Remain In-Service 2  33 122    c07  0.s3  PCT  l8 Horizontal Grid Wear Remain In-Service 2  36    7  c06  -0.84  PCT  l8 Horizontal Grid Wear Remain In-Service 2  36 t2t  c03  -0.92  PCT  20  Horizontal Grid Wear Remain In-Service 2  37    8  c03  0.75  PCT  l8 Horizontal Grid Wear Remain In-Service 2  38    7  c03  0.94  PCT  t6 Horizontal Grid Wear Remain In-Service 2  39    8  c07    1.07 PCT  t5 Horizontal Grid Wear Remain In-Service 2  47  l0  c03  0.88  PCT  t9 Horizontal Grid Wear Remain In-Service 2  50    9  c04    -0.9  PCT  l9  Horizontal Grid Wear Remain In-Service 2  5l ll8  c03  -0.98  PCT  l8  Horizontal Grid Wear Remain In-Service 2  53 I  l8 c03  -0.89  PCT  2t  Horizontal Grid Wear Remain In-Service 2  s9 tt4  c04  0.62  PCT  l5  Horizontal Grid Wear Remain In-Service 2  60 I  15 c03  -0.96  PCT  l9  Horizontal Grid Wear Remain In-Service 2  60 ll5  c06    l.t2 PCT  l9  Horizontal Grid Wear Remain In-Service 2  60 I  l5 c07    l.0r PCT  l7  Horizontal Grid Wear Remain In-Service 2  62  l5  c0s  0.67  PCT  l9  Horizontal Grid Wear Remain In-Service 2  62  t5  c04    1.03 PCT  l7  Horizontal Grid Wear Remain In-Service 2  62 ll3  c07  -0.98  PCT  25  Horizontal Grid Wear Remain In-Service 2  62 ll3  c03  -0.95  PCT  l8  Horizontal Grid Wear Remain In-Service 2  62 n3    c04  0.62  PCT  l8  Horizontal Grid Wear Remain In-Service 2  63 tt4  c03    1.04  PCT  t7  Horizontal Grid Wear Remain In-Service 2  63 tt4  c06  0.64  PCT  l5  Horizontal Grid Wear Remain In-Service 2  64 l13  c03  -0.87  PCT  t7  Horizontal Grid Wear Remain In-Service 2  7l ll0  c05  0.65  PCT  t6  Horizontal Grid Wear Remain In-Service 2  72 109  c03    -t.2  PCT  20  Horizontal Grid Wear Remain In-Service 2  76 107  c03  0.65  PCT  l6  Horizontal Grid Wear Remain In-Service 2  77 104  c03  -0.76  PCT  t9  Horizontal Grid Wear Remain In-Service 2  77 104  c04    I .01 PCT  l8  Horizontal Grid Wear Remain In-Service 2  78 105  c03  -0.82  PCT  l8  Horizontal Grid Wear Remain In-Service 2  79 IM    c03    1.04  PCT  l8  Horizontal Grid Wear Remain In-Service 2  79 104  c04  -0.96  PCT  t7  Horizontal Grid Wear Remain In-Service 2  80 103  c06  -0.9s  PCT  l9  Horizontal Grid Wear Remain In-Service 2  83 100  c04  0.54  PCT  20  Horizontal Grid Wear Remain In-Service 2  85 100  c06  -0.99  PCT  2t  Horizontal Grid Wear Remain In-Service 2  85 r00  c04  0.65  PCT  l9  Horizontal Grid Wear Remain In-Service 2  85 100  c07    1.22  PCT  l8  Horizontal Grid Wear Remain In-Service 2  86  97  c04  0.89  PCT  l8  Horizontal Grid Wear Remain In-Service SG-SGMP-17-20                                                                June 2017 Revision 0                                                                  Page 12 of 19
SG Row  Col Locn Inchl  Ind %TW  Characterization      Resolution 2  86  97  c03    0.68  PCT  l7 Horizontal Grid Wear Remain In-Service 2  86  99  c04  0.7  PCT  22 Horizontal Grid Wear Remain In-Service 2  87  30  c03  0.74  PCT  l8 Horizontal Grid Wear Remain In-Service 2  87  32  c06    1.72 PCT  t9 Horizontal Grid Wear Remain In-Service 2  87  94  c04  0.73  PCT  20 Horizontal Grid Wear Remain In-Service 2  87  98  c06  -0.95  PCT  30 Horizontal Grid Wear Remain In-Service 2  87  98  c03  -0.9s  PCT  23 Horizontal Grid Wear Remain In-Service 2  87  98  c04  0.67  PCT  l9 Horizontal Grid Wear Remain In-Service 2  88  95  c03    1.04 PCT  37 Horizontal Grid Wear Remain In-Service 2  88  95  c03  0.53  PCT  t6 Horizontal Grid Wear Remain In-Service 2  88  95  c06  0.78  PCT  l6 Horizontal Grid Wear Remain In-Service 2  89  32  c03  -0.94  PCT  t9 Horizontal Grid Wear Remain In-Service 2  89  32  c03  0.82  PCT  l6 Horizontal Grid Wear Remain In-Senrice 2  89  94  c03  -0.98  PCT  25 Horizontal Grid Wear Remain In-Service 2  89  96  c06    1.04 PCT  t7 Horizontal Grid Wear Remain In-Service 2  90  95  c04  0.73  PCT  23 Horizontal Grid Wear Remain In-Service 2  90  95  c07  -0.95  PCT  l8 Horizontal Grid Wear Remain In-Service 2  9t  94  c03  -0.92  PCT  25 Horizontal Grid Wear Remain In-Service 2  92  35  c04  -0.86  PCT  l7 Horizontal Grid Wear Remain In-Service 2  92  35  c03  -0.92  PCT  l6 Horizontal Grid Wear Remain In-Service 2  92  93  c07  -0.87  PCT  l9 Horizontal Grid Wear Remain In-Service 2  92  93  c04  0.73  PCT  l8 Horizontal Grid Wear Remain In-Service 2  92  93  c06  -0.88  PCT  l8 Horizontal Grid Wear Remain In-Service 2  95  82  c03    l.l5 PCT  l7 Horizontal Grid Wear Remain In-Service 2  96  85  c06  0.89  PCT  t9 Horizontal Grid Wear Remain In-Service 2  96  85  c07    1.06 PCT  t7 Horizontal Grid Wear Remain In-Service 2  96  87  c03  -0.82  PCT  t8 Horizontal Grid Wear Remain In-Service 2  97  86  c03    t.t2 PCT  l9 Horizontal Grid Wear Remain In-Service
          )  97  88  c03  -0.96  PCT  20 Horizontal Grid Wear Remain In-Service 2  98  43  c05  0.71  PCT  20 Horizontal Grid Wear Remain In-Service 2  98  79  c03    t.t2 PCT  l9 Horizontal Grid Wear Remain In-Service 2  98  83  c03    l.l8 PCT  l8 Horizontal Grid Wear Remain In-Service 2  99  84  c02  0.62  PCT  l6 Horizontal Grid Wear Remain In-Service 2  100 8l  c04  0.78  PCT  23 Horizontal Grid Wear Remain In-Service 2  l0l 78  c03    l.l5 PCT  20 Horizontal Grid Wear Remain In-Service 2  l0l 80  c03    1.2 PCT  20 Horizontal Grid Wear Remain In-Service 2  103 62  c03  0.92  PCT  t7 Horizontal Grid Wear Remain In-Service 2  103 66  c05  0.67  PCT  22 Horizontal Grid Wear Remain In-Service 2  103 74  c03    l.l5 PCT  l9 Horizontal Grid Wear Remain In-Service 2  104 6l  c06  -0.9  PCT  l6 Horizontal Grid Wear Remain In-Service 2  104 69  c05    0.7  PCT  t9 Horizontal Grid Wear Remain In-Service 2  105 66  c03  0.72  PCT  23 Horizontal Grid Wear Remain In-Service 2  105 66  c05  0.67  PCT  t7 Horizontal Grid Wear Remain In-Service 2  105 68  c03  0.75  PCT  20 Horizontal Grid Wear Remain In-Service SG-SGMP-17-20                                                            June 2017 Revision 0                                                                Page 13 of 19
Table2-72            UlRl4 Horimntal able 2-72 Watts Bar U1R14      Horizontal Tube Su Suooort Grid Wear    tnotcauons ear Indications - SG 3 SG    Row    Col    Locn    Inchl      Ind  %TW    Characterization          Resolution 3      I    72    H04      -0.88    PCT    l5    Horizontal Grid Wear    Remain In-Service 3      I    72    H05      -0.96    PCT    t4    Horizontal Grid Wear    Remain In-Service 3      I    72    H04      0.91    PCT    l3    Horizontal Grid Wear    Remain In-Service 3      I    78    H04      -0.9r    PCT    20    Horizontal Grid Wear    Remain In-Service 3      I    86    H04      -0.85    PCT    l5    Horizontal Grid Wear    Remain In-Service 3      7      2  c03      0.83    PCT    t6    Horizontal Grid Wear    Remain In-Service 3      9    r06    c06      -0.78    PCT    l8    Horizontal Grid Wear    Remain In-Service 3    l0        I  c03      0.72    PCT    23    Horizontal Grid Wear    Remain In-Service 3      l0      I  c05      -0.92    PCT    t7    Horizontal Grid Wear    Remain In-Service 3      l3      4  c03      0.75    PCT    l8    Horizontal Grid Wear    Remain In-Service 3      t4    5l    Hl0      0.68    PCT    l8    Horizontal Grid Wear    Remain In-Service 3      t4    5l    clt        1.06    PCT    t7    Horizontal Grid Wear    Remain In-Senrice 3      t4    8r    H06      -0.9    PCT    t8    Horizontal Grid Wear    Remain In-Service 3      l5      2  c04      -0.97    PCT    20    Horizontal Grid Wear    Remain In-Service 3    l5        2  c03      0.83    PCT    t7    Horizontal Grid Wear    Remain In-Service 3      l5      4  c06      -0.91    PCT    l9    Horizontal Grid Wear    Remain In-Service 3    t7    102    ct2      1.06    PCT    20    Horizontal Grid Wear    Remain In-Service 3      t7    t02    cl2      0.66    PCT    l8    Horizontal Grid Wear    Remain In-Service 3    l8      53    ct2    -0.89    PCT    t7    Horizontal Grid Wear    Remain In-Service 3    l9        2  c04      -0.98    PCT    23    Horizontal Grid Wear    Remain In-Service 3    20      6t    cl0      -0.98    PCT    l9    Horizontal Grid Wear    Remain In-Service 3    23    t24    c06      0.69    PCT    23    Horizontal Grid Wear    Remain In-Service 3    24        3  c05        0.8    PCT    l8    Horizontal Grid Wear    Remain In-Service 3    26        5  c03      -0.8    PCT    l8    Horizontal Grid Wear    Remain In-Service 3    28    I  l9  ct2      -0.86    PCT    l8    Horizontal Grid Wear    Remain In-Service 3    32        5  c03      -0.89    PCT    l8    Horizontal Grid Wear    Remain In-Service 3    34        5  c03          I    PCT    20    Horizontal Grid Wear    Remain In-Service 3    53    r  r8  c06      0.69    PCT    l6    Horizontal Grid Wear    Remain In-Service 3    59      t4  c03        1.03    PCT    2t    Horizontal Grid Wear    Remain In-Service 3    6t    tt4    c06      0.83    PCT    26    Horizontal Grid Wear    Remain In-Service 3    6l    tt4    c06      -0.75    PCT    t7    Horizontal Grid Wear    Remain In-Service 3    64      l7  c03      -0.89    PCT    l6    Horizontal Grid Wear    Remain In-Service 3    64    lll    c04      -0.77    PCT    l8    Horizontal Grid Wear    Remain In-Service 3    64    lll    c07          I    PCT    t4    Horizontal Grid Wear    Remain In-Service 3    65      l8  c03      -0.98    PCT    l8    Horizontal Grid Wear    Remain In-Service 3    67    n2    c06        l.l I  PCT    t6    Horizontal Grid Wear    Remain In-Service 3    68      t9  c03      0.63    PCT    l8    Horizontal Grid Wear    Remain In-Service 3    7l    r04    c03      0.87    PCT    l7    Horizontal Grid Wear    Remain In-Service 3    76    t07    c04      0.75    PCT    2t    Horizontal Grid Wear    Remain In-Service 3    76    t07    c06        0.8    PCT    20    Horizontal Grid Wear    Remain In-Service 3    77      22    c03      0.72    PCT    l6    Horizontal Grid Wear    Remain In-Service 3    79      24    c03      0.75    PCT    l8    Horizontal Grid Wear    Remain In-Service 3    82      25    c03      0.69    PCT    t6    Horizontal Grid Wear    Remain In-Service 3    82      27    c03      0.67    PCT    l6    Horizontal Grid Wear    Remain In-Service 3    83      26    c03      0.95    PCT    l5    Horizontal Grid Wear    Remain In-Service 3    84      29    c03      0.72    PCT    20    Horizontal Grid Wear    Remain In-Senrice 3    84      95    c05      0.91    PCT    l6    Horizontal Grid Wear    Remain In-Service SG-SGMP-17-20                                                                                      June 2017 Revision 0                                                                                        Page 14 of 19
SG  Row Col Locn Inchl  Ind o/oTW  Characterization      Resolution 3  84 99  c03  -0.92  PCT  t7  Horizontal Grid Wear Remain In-Service 3  85 28  c03    0.7s  PCT  2t  Horizontal Grid Wear Remain In-Service 3  85 96  c03    0.8  PCT  l8  Horizontal Grid Wear Remain In-Service 3  85 98  c02  -0.94  PCT  22  Horizontal Grid Wear Remain In-Service 3  86 3l  c03    0.66  PCT  t7  Horizontal Grid Wear Remain In-Service 3  86 95  c03    0.7 l PCT  20  Horizontal Grid Wear Remain In-Service 3  86 97  c02  -0.82  PCT  22  Horizontal Grid Wear Remain In-Service 3  86 99  c05    0.74  PCT  22  Horizontal Grid Wear Remain In-Service 3  86 99  c02  -0.85  PCT  2t  Horizontal Grid Wear Remain In-Service 3  86 99  c04    0.62  PCT  l8  Horizontal Grid Wear Remain In-Service 3  86 99  c03  -0.89  PCT  t7  Horizontal Grid Wear Remain In-Service 3  89 32  c03    0.69  PCT  l8  Horizontal Grid Wear Remain In-Service 3  89 96  c03  -0.92  PCT  22  Horizontal Grid Wear Remain In-Servrce 3  90 33  c03    0.66  PCT  2t  Horizontal Grid Wear Remain In-Service 3  90 93  c04  -0.97  PCT  l5  Horizontal Grid Wear Remain In-Service 3  90 95  c04  -0.8s  PCT  t8  Horizontal Grid Wear Remain In-Service 3  90 95  c03    -0.8  PCT  l7  Horizontal Grid Wear Remain In-Service 3  9t 34  c03  -0.92  PCT  25  Horizontal Grid Wear Remain In-Service 3  92 35  c03  -0.98  PCT  25  Horizontal Grid Wear Remain In-Service 3  92 9l  c03  -0.83  PCT  l9  Horizontal Grid Wear Remain In-Service 3  92 9l  c0s  -0.95  PCT  t6  Horizontal Grid Wear Remain In-Service 3  92 93  c04  -0.98  PCT  t7  Horizontal Grid Wear Remain In-Service 3  93 36  c03  -0.89  PCT  l8  Horizontal Grid Wear Remain In-Service 3  93 36  c04    0.69  PCT  18  Horizontal Grid Wear Remain In-Service 3  93 90  c03    0.8  PCT  l9  Horizontal Grid Wear Remain In-Service 3  94 37  c06  -0.92  PCT  t9  Horizontal Grid Wear Remain In-Service 3  94 4t  c07    t.t2 PCT  21  Horizontal Grid Wear Remain In-Service 3  94 89  c03  -0.92  PCT  l8  Horizontal Grid Wear Remain In-Service 3  95 38  c02  -0.77  PCT  l9  Horizontal Grid Wear Remain In-Service 3  95 38  c04    0.69  PCT  t7  Horizontal Grid Wear Remain In-Service 3  96 85  c06  0.79  PCT  19  Horizontal Grid Wear Remain In-Service 3  97 40  c04  0.72  PCT  t6  Horizontal Grid Wear Remain In-Service 3  97 42  c04  0.69  PCT  26  Horizontal Grid Wear Remain In-Service 3  97 42  c06  0.86  PCT  t6  Horizontal Grid Wear Remain In-Service 3  100 75  c03    0.72  PCT  l8  Horizontal Grid Wear Remain In-Service 3  t0l 68  c03    0.8  PCT  2l  Horizontal Grid Wear Remain In-Service SG-SGMP-17-20                                                              June 2017 Revision 0                                                                  Page 15 of 19
aDte l-IJi 2-8  w warfstts lrar  ull(rlt rlo Ba U1Rl4 a
H rUZO n tal T u be Su  rt Grid Wear Indications -  SG 4 SG  Row      Col      Locn    Inchl        Ind        o/oTW  Characterization      Resolution 4    3      42        cil      -0.96        PCT          23  Horizontal Grid Wear  Remain In-Service 4    3      42        ct2        1.09      PCT          l9  Horizontal Grid Wear  Remain In-Service 4    6      37        cll        I .01    PCT          t7  Horizontal Grid Wear  Remain In-Service 4    6      73        H07      -0.87        PCT          2l  Horizontal Grid Wear  Remain In-Service 4    6      127        c03      0.76        PCT          23  Horizontal Grid Wear  Remain In-Service 4    9      40        cll      -0.96        PCT          t7  Horizontal Grid Wear  Remain In-Service 4    9      42        H06        0.62        PCT          24  Horizontal Grid Wear  Remain In-Service 4    9      42        H07        0.72        PCT          t7  Horizontal Grid Wear  Remain In-Service 4    l0      4t        c09      -0.87        PCT          t9  Horizontal Grid Wear  Remain In-Service 4    l0      6l        H07        t.t2      PCT          l8  Horizontal Grid Wear  Remain In-Service 4    t2      7l        H06      -0.86        PCT          22  Horizontal Grid Wear  Remain ln-Service 4    t2      7l        H07      -t.23        PCT          22  Horizontal Grid Wear  Remain In-Service 4    l3      78        cl0      0.64        PCT          3l  Horizontal Grid Wear  Remain In-Service 4    t4        3        c04      0.69        PCT          20  Horizontal Grid Wear  Remain In-Service 4    r8      63        ct2      0.61        PCT          23  Horizontal Grid Wear  Remain In-Service 4    l8      63        cll      0.64        PCT          2t  Horizontal Grid Wear  Remain In-Service 4  22      123        c03          l.l      PCT          l8  Horizontal Grid Wear  Remain In-Service 4  23      t24        c03      -0.88        PCT          2t  Horizontal Grid Wear  Remain In-Service 4  23      r24        c06      -0.84        PCT          2t  Horizontal Grid Wear  Remain In-Service 4  24      9l        H06      -0.22      PCT          t9 Horizontal Grid Wear  Remain In-Service 4  24      125        c03      0.87        PCT          24  Horizontal Grid Wear  Remain In-Service 4  24      t25        c06      0.75        PCT          l8 Horizontal Grid Wear  Remain In-Service 4  25        62        cll      0.67        PCT          20  Horizontal Grid Wear  Remain In-Service 4    26      3s        ct2      -0.92      PCT          t7 Horizontal Grid Wear  Remain In-Service 4  26      t23        c04      0.7 6      PCT          2t  Horizontal Grid Wear  Remain In-Service 4  26      123        c08      -0.93        PCT          l9 Horizontal Grid Wear  Remain In-Service 4  26      123        c03        -0.9      PCT          l8 Horizontal Grid Wear  Remain In-Service 4    27      124        c03      -0.93        PCT          23  Horizontal Grid Wear  Remain In-Service 4    28      123        c04      -0.87        PCT          20  Horizontal Grid Wear  Remain In-Service 4    30        5        c05      -0.78        PCT          l8 Horizontal Grid Wear  Remain In-Service 4    3l      124        c03      -0.93        PCT          20  Horizontal Grid Wear  Remain In-Service 4    32        5        c02      0.76        PCT          t7 Horizontal Grid Wear  Remain In-Service 4    32        7        c02      0.82        PCT          20  Horizontal Grid Wear  Remain In-Service 4    32        7        c03      0.73        PCT          l8 Horizontal Grid Wear  Remain In-Service 4    33        8        c03      0.94        PCT          l8 Horizontal Grid Wear  Remain In-Service 4    3s      t22        c03      0.97        PCT          20  Horizontal Grid Wear  Remain In-Service 4    43        8        c04      0.98        PCT          l9 Horizontal Grid Wear  Remain In-Service 4  44        9        c06        -0.7      PCT          l8 Horizontal Grid Wear  Remain In-Service 4    44      t2t        c03          I      PCT          22  Horizontal Grid Wear  Remain In-Service 4    45        8        c03      -0.82        PCT          r8 Horizontal Grid Wear  Remain In-Service 4    49      il0        ct2      -0.48        PCT          l8 Horizontal Grid Wear  Remain In-Service 4    50      87        H0l      -t.22      PCT          l9 Horizontal Grid Wear  Remain In-Service 4    53      r l8      c02      -0.87        PCT          2l  Horizontal Grid Wear  Remain In-Service 4    60      I 15      c07        0.9      PCT          18 Horizontal Grid Wear  Remain In-Service 4    63      tt4        c06        l.l  I    PCT          2l  Horizontal Grid Wear  Remain In-Service 4    6s      tt2        c05      -0.84        PCT          t9 Horizontal Grid Vlear Remain In-Servrce 4    7t      108        c06      0.73        PCT          t6 Horizontal Grid Wear  Remain In-Service SG-SGMP-17-20                                                                                          June 2017 Revision 0                                                                                              Page 16 of 19
SG Row  Col Locn Inchl    Ind o/oTW  Characterization      Resolution 4  77 104 c03  0.71    PCT  26  Horizontal Grid Wear Remain In-Service 4  78 103 c03    0.8  PCT  t8  Horizontal Grid Wear Remain In-Service 4  83  98 c03  0.71    PCT  l8  Horizontal Grid Wear Remain In-Service 4  83  98 c04    -0.9  PCT  t6  Horizontal Grid Wear Remain In-Service 4  83 100 c03  0.72    PCT  20  Horizontal Grid Wear Remain In-Service 4  84  97 c04  -0.94  PCT  20  Horizontal Grid Wear Remain In-Service 4  84  97 c03  0.74    PCT  l9  Horizontal Grid Wear Remain In-Service 4  84 l0l c04  -0.94  PCT  22  Horizontal Grid Wear Remain In-Service 4  84 l0l c03    0.71  PCT  2t  Horizontal Grid Wear Remain In-Senrice 4  84 l0r  c02  0.68  PCT  20  Horizontal Grid Wear Remain In-Service 4  84 l0l c06  -0.91  PCT  l8  Horizontal Grid Wear Remain In-Service 4  85  28 c03  -0.86  PCT  22  Horizontal Grid Wear Remain In-Service 4  85  94 c03  -0.84  PCT  20  Horizontal Grid Wear Remain In-Service 4  85  96  c04  -0.95  PCT  t8  Horizontal Grid Wear Remain In-Service 4  85 100  c04  -0.86  PCT  20  Horizontal Grid Wear Remain In-Service 4  87  92  CM    0.78  PCT  r9  Horizontal Grid Wear Remain In-Service 4  87  96  c03  -0.89  PCT  24  Horizontal Grid Wear Remain In-Service 4  87  96  c05  -0.72  PCT  t9  Horizontal Grid Wear Remain In-Service 4  87  98  c04  -0.89  PCT  20  Horizontal Grid Wear Remain In-Service 4  88  3l  c03  -0.95  PCT  22  Horizontal Grid Wear Remain In-Service 4  88  95  c03  -0.75  PCT  t7  Horizontal Grid Wear Remain In-Service 4  89  94  c0s  0.66  PCT  t7  Horizontal Grid Wear Remain In-Service 4  89  96  c03  -0.89  PCT  23  Horizontal Grid Wear Remain In-Service 4  89  96  c05  0.7  l PCT  l8  Horizontal Grid Wear Remain In-Service 4  90  35  c03    I .18 PCT  l9  Horizontal Grid Wear Remain In-Service 4  90  39  c04  0.88  PCT    l7 Horizontal Grid Wear Remain In-Service 4  90  9l  c04  -0.92  PCT  l8  Horizontal Grid Wear Remain In-Service 4  9l  34  c03  -0.89  PCT  24  Horizontal Grid Wear Remain In-Service 4  9t  34  c05  0.74  PCT  20  Horizontal Grid Wear Remain In-Service 4  9l  36  c04  0.7 t  PCT  22  Horizontal Grid Wear Remain In-Service 4  9l  36  c03    -t.2  PCT  2l  Horizontal Grid Wear Remain In-Service 4  9l  38  c03  -0.92  PCT  22  Horizontal Grid Wear Remain In-Service 4  9l  92  c04  -0.8  PCT  20  Horizontal Grid Wear Remain In-Service 4  9l  94  c03  0.71  PCT  23  Horizontal Grid Wear Remain In-Service 4  92  37  c03  -0.86  PCT  25  Horizontal Grid Wear Remain In-Service 4  92  9l  c03  0.65  PCT  t7  Horizontal Grid Wear Remain In-Service 4  92  93  c03  0.74  PCT  20  Horizontal Grid Wear Remain In-Service 4  93  36  c03  -0.t 4  PCT  22  Horizontal Grid Wear Remain In-Service 4  93  36  c05  0.68  PCT  2t  Horizontal Grid Wear Remain In-Service 4  94  37  c03    t.l7  PCT  34  Horizontal Grid Wear Remain In-Service 4  94  39  c03  -0.86  PCT  22  Horizontal Grid Wear Remain In-Service 4  94  39  c07  -0.92  PCT  l8  Horizontal Grid Wear Remain In-Service 4  94  4l  c03  -0.92  PCT  23  Horizontal Grid Wear Remain In-Service 4  95  40  c0s  0.71  PCT    l9 Horizontal Grid Wear Remain In-Service 4  95  40  c06    1.03  PCT    l8 Horizontal Grid Wear Remain In-Service 4  95  42  c03  -0.83  PCT  26  Horizontal Grid Wear Remain In-Service 4  95  86  c03  0.68  PCT  24  Horizontal Grid Wear Remain In-Service 4  96  4t  c03  0.7  l PCT  22  Horizontal Grid Wear Remain In-Service SG-SGMP-17-20                                                              June 2017 Revision 0                                                                Page 17 of 19
SG  Row      Col      Locn    Inchl    Ind %TW    Characterization          Resolution 4    96        4l      c0s      -0.98    PCT  l9  Horizontal Grid Wear      Remain In-Service 4    96        43      c03      -0.95    PCT  l9  Horizontal Grid Wear      Remain In-Service 4    96        45      c03      -0.92    PCT  2l  Horizontal Grid Wear      Remain In-Service 4    96        8l      c03      0.92    PCT  l8  Horizontal Grid Wear      Remain In-Service 4    97        42      c0s      -0.97    PCT  22  Horizontal Grid Wear      Remain In-Service 4    97        78      c03      0.8 r  PCT  2l  Horizontal Grid Wear      Remain In-Service 4    97        86      c03      0.74    PCT  25  Horizontal Grid Wear      Remain In-Service 4    97      88      c03        0.8    PCT  2t  Horizontal Grid Wear      Remain In-Service 4    97      88      c03      -0.74    PCT  18  Horizontal Grid V/ear    Remain In-Service 4    97      88      c07      -0.86    PCT  18  Horizontal Grid Wear      Remain In-Service 4    98      43      c07      0.77    PCT  l9  Horizontal Grid Wear      Remain In-Service 4    98      43      c03      -0.95    PCT  l8  Horizontal Grid Wear      Remain In-Service 4    98      45      c03      -0.94    PCT  30  Horizontal Grid Wear      Remain In-Service 4    98      8l      c03      0.59    PCT  l8  Horizontal Grid Wear      Remain In-Service 4    98      85      c03      0.7 l  PCT  23  Horizontal Grid Wear      Remain In-Service 4    99      4        c03      0.88    PCT  t9  Horizontal Grid Wear      Remain In-Service 4    99      44      c06      0.79    PCT  t7  Horizontal Grid Wear      Remain In-Service 4    99      44      c08      0.71    PCT  l7  Horizontal Grid Wear      Remain In-Service 4    99      46      c03      -0.89    PCT  22  Horizontal Grid Wear      Remain In-Service 4    100      8r      c03        0.7    PCT  l8  Horizontal Grid Wear      Remain In-Service 4    100      83      c03      -0.86    PCT  2t  Horizontal Grid Wear      Remain In-Service 4    100      83      c07        t.t7  PCT  l8  Horizontal Grid Wear      Remain In-Service 4    l0t      80      c03        0.7    PCT  20  Horizontal Grid Wear      Remain In-Service 4    t02      49      c03        0.8    PCT  2l  Horizontal Grid Wear      Remain In-Service 4    r02      5l      c04      0.78    PCT  l9  Horizontal Grid Wear      Remain In-Service 4    t02      79      c03      0.73    PCT  l9  Horizontal Grid Wear      Remain In-Service 4    103      76      c03      0.67    PCT  2t  Horizontal Grid Wear      Remain In-Service 4    104      7l      c03      -0.9    PCT  23  Horizontal Grid Wear      Remain In-Service
: e. Number of Tubes Plugged During the Inspection Outage for Each Active Degradation Mechanism There were no tubes required to be plugged during the Watts Bar UlRl4 RSG in-service inspection. Table 2-9 below provides the numbers of tubes plugged for each degradation mechanism detected. This table also shows the numbers of tubes plugged before and after the UlRl4 outage as well as the percentage of tubes currently plugged.
Table 2-92 Number of Tubes Plugged for Each Degradation Mechanism sclr  scr2      SG13      SG14      Total Plugged Tubes prior to  UlRl4      3      5        7        t4      29 Plugged for U-bend Support Structure Wear    0    0          0          0        0 Plugged for Horizontal Grid Wear      0    0          0          0        0 Total Plugged to Date          3      5        7        t4      29 Percentage Plugged to Date        0.06% 0.t0%    0.r4%    0.274/0  a.r4%
SG-SGMP-17-20                                                                                    June 2017 Revision 0                                                                                      Page l8 of 19
: f. Total Number and Percentage of Tubes Plugged to Date Table 2-9 in the previous section provides the number and percentage of tubes plugged to date.
: g. The Results of Condition Monitoring, Including the Results of Tube Pulls and In-Situ Testing Tube Inteerity A  condition monitoring (CM) assessment was performed as required by the WBNI steam generator progfam. The only tube degradation detected during the U1Rl4 inspection was wear at tube support structures. The deepest indication had an estimated depth of 37%Ttl from the bobbin probe exam and was located at a horizontal support grid. Conservatively assuming an enveloping flaw length slightly greater than the width of the support (2.0 inches), the CM limit for horizontal support grid wear is 52%TW. This CM limit includes uncertainties for material properties, NDE depth sizing, and the burst pressure relationship. Since the deepest flaw has an estimated depth less than the conservatively determined CM limit, the stnrctural integrity perfonnance criterion was met for the operating interval prior to UlR14.
Since volumetric wear indications will leak and burst at essentially the same pressure, accident-induced leakage integnty at a much lower accident pressure differential is also demonstrated.
Operational leakage integrity was demonstrated by the absence of any detectable primary-to-secondary leakage during the operating interval prior to UlRl4. Since tube integrity was demonstrated analytically, in-sitr,r pressure testing was not required nor perfonned during the UlRl4 outage. No tube pulls were planned or performed during UlRl4.
Visual Insoection Results Visual inspections were performed on both the primary and secondary sides during UlR14.
Primary side inspections included visual inspections of all previously installed tube plugs as well as the channel head bowl cladding and the divider plate. The installed tube plug inspections showed no conditions indicative of improper installation or in-service degradation. The visual inspections of the channel head bowl cladding and the divider plate showed no visually apparent evidence of degradation of the cladding, divider plate, or divider plate welds.
Prior to the secondary side foreign object search and retrieval (FOSAR) inspections, sludge, scale, foreign objects, and other deposit accumulations at the top of the tubesheet were removed as part of the top of tubesheet sludge lancing process. The secondary side FOSAR inspections performed in all four SGs included visual examination of tube bundle periphery tubes from the hot leg and cold leg annulus and center no tube lane. A total of 6 foreign objects were removed from the top of the tubesheet region and 6 objects remain on the secondary side among the four SGs. The foreign objects remaining are all small pieces of metal, wires, and bristles. Any foreign objects not able to be retrieved were characteized and an analysis performed to demonstrate acceptability of continued operation without exceeding the performance criteria. A limited top of tubesheet in-bundle visual inspection was also performed in each SG for the purpose ofassessing and frending the level ofhardened deposit buildup in the kidney regron.
: h. The Effective Plugging Percentage for    All Plugging in Each SG There are no sleeves installed in the WBN1 replacement SGs. Therefore, the effective plugging percentage is the same as the plugging percentage shown in Table 2-9.
SG-SGMP-17-20                                                                                June 2017 Revision 0                                                                                  Page 19 of 19}}

Latest revision as of 00:08, 30 October 2019

Cycle 14 Steam Generator Tube Inspection Report
ML17209A554
Person / Time
Site: Watts Bar Tennessee Valley Authority icon.png
Issue date: 07/28/2017
From: Simmons P
Tennessee Valley Authority
To:
Document Control Desk, Office of Nuclear Reactor Regulation, NRC/RGN-II
References
SC-SGMP-17-20, Rev. 0
Download: ML17209A554 (22)


Text

Tennessee Valley Authority, Post Office Box 2000, Spring City, Tennessee 37381 July 28,2017 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Watts Bar Nuclear Plant, Unit 1 Facility Operating License No. NPF-90 NRC Docket No. 50-390

Subject:

Watts Bar Nuclear Plant (WBN) Unit 1 - Cycle 14 Steam Generator Tube lnspection Report ln accordance with the requirements of WBN Technical Specification (TS) 5.9.9, "Steam Generator Tube lnspection Report," the Enclosure provides the 180 Day Steam Generator lnspection Report for Unit 1 Cycle 14. This report is required to be submitted within 180 days after the initial entry into MODE 4 following the completion of an inspection performed in accordance with TS 5.7.2.12, "Steam Generator (SG) Program." The report provides the complete results of the tube inspections.

There are no regulatory commitments in this submittal. Please direct any questions concerning this matter to Kasey Decker, WBN Site Licensing, at 423-365-3173.

Respectfully, Pau! Simmons Site Vice President Watts Bar Nuclear Plant

Enclosure:

Watts Bar U1R14 180 Day Steam GeneratorTube Inspection Report cc: See Page 2

U.S. Nuclear Regulatory Commission Page 2 July 28,2017 Enclosures cc (Enclosures):

NRC Regional Administrator - Region ll NRC Project Manager - Watts Bar Nuclear Plant, Unit 1 NRC Senior Resident lnspector - Watts Bar Nuclear Plant, Unit 1

Enclosure Watts Bar UlR14 180 Day Steam Generator Tube lnspection Report

WTSTTNGHOUSE NON-PnoprueTARY CIess 3 SCr-SGMP-17-20 June 2017 Revision 0 Watts Bar U1R14 180 Day Steam Generator TUbe Inspection Report

WESTINGHOUSE NON-PROPRIETARY CLASS 3 SCr-SGMP-17-20 Revision 0 Waffs Bar U1R14 180 Day Steam Generator Tube Inspection Report Prepared for:

Tennessee Valley Authority Author's Name: Signature lDate For Pages William R. LaMantia *EI ec tron i caII v A p pro ved All SG Management Programs Verifier's Name: Signature lDate For Pages Jesse S. Baron *EI ectron i c aII v A p pro ved All SG Management Programs Manager's Name: Signature I Date For Pages David P. Lytle, Manager *Electronicallv A o oroved All SG Management Programs Revierverts Name: Signnture I Date For Fageo Jercmyl[/. Mayo TYA SGPrograrnManager Reviewer'sNnmel Signature /

Tarnmy C. $ears TYA Watts Bar SG Progmm O$mer Rtvlewgr'r Nnnrtr Sign*ffir* / Date For Pages DaniclP, Folsom TYA NDHLevel III

-"&\

  • Electronically Approved Records are Authcnticeted in the Elcafronic Document Menagcmeat System 02017 Westinghouse Electric Company LtC Alt Rights Reserved SG-SGMP-17-20 June 2017 Revision 0 Page 2 of 19

Record of Revisions Revision Date Description June 0a Preliminary draft for Tennessee Valley Authority review and corrment.

2017 See 0 Original Issue EMDS SG-SGMP-17-20 June 2017 Revision 0 Page 3 of 19

Table of Contents 2.0 180 Day Steam Generator Tube lnspection Report ..........6

a. The Scope of the Inspections Performed on Each SG............. ...............6
b. Active Degradation Mechanisms Found...... ........................6
c. Nondestructive Examination (NDE) Techniques Used for Each Degradation Mechanism..........6
d. Location, Orientation (if Linear), and Measured Sizes (if Available) of Service lnduced Indications. ..................7
e. Number of Tubes Plugged During the Inspection Outage for Each Active Degradation Mechanism ................18
f. Total Number and Percentage of Tubes Plugged to Date ..................... 19 o

D. The Results of Condition Monitoring, Including the Results of Tube Pulls and In-Situ Testinglg

h. The Effective Plugging Percentage for All Plugging in Each SG.............. .............. 19 List of Tables and Figures Figure l-l: Tube Support Arrangement for Watts Bar Unit I Model 68AXP Replacement Steam Generators .5 Table 2-l: Watts Bar UlRl4 Steam Generator Eddy Current Inspection Scope......... .....................6 Table2-2: Number of lndications Detected for Each Degradation Mechanism ............6 Table 2-3: NDE Techniques for Each Existing or Potential Degradation Mechanism............. ........7 Table 24: Watts Bar UlRl4 U-bend Support Stnrcture Wear Indications - All SGs ............ ..........7 Table 2-5: Watts Bar UlR14 Horizontal Tube Support Grid Wear Indications - SG 1........... .........9 Table2-9: Number of Tubes Plugged for Each Degradation Mechanism ...................18 SG-SGMP-17-20 Jnne 2017 Revision 0 Page 4 of 19

1.0 Introduction Inspections of the replacement steam generators (SGs) were perforrned during the Watts Bar Unit 1 (WBNI) spring 2017 refueling outage designated as (UlRl4). These inspections included eddy current test.g of the SG tubing as well as primary and secondary side cleanings and visual inspections. This report documents the "Watts Bar UlRl4 180-Day Steam Generator Tube lnspection Report" as required by the WBN1 Technical Specifications.

The original steam generators at WBNI were replaced in 2006 with Westinghouse Model 68AXP SGs which have thermally treated Alloy 690 tubing. The UlRl4 inspection was the third in-service inspection of the replacement SGs. Prior to the UlRl4 inspection, the replacement SGs had operated for seven (7) fuel cycles since replacement. The replacement SGs had operated for tbree (3) fuel cycles since the previous inspection at UlRl l. Figure l-l below provides the arrangement and location designation of the tube support structures for the WBN1 SGs.

AXIAL fLott ilL.-,- C0LD SIDI

);rr RECIRCULATING TNTRANCT CROSS TLOW HOT SIDE RECIRCULATINO ENTRANCT CROSS TLOW Figure 1-1: Tube Support Arrangement for Watts Bar Unit I Model68AXP Replacement Steam Generators Notes: VS : Vertical Strap DS : Diagonal Strap HTS/CTS : Hot/Cold Tubesheet (designates top of tubesheet)

HTE/CTE : Hot/Cold Tube End Horizontal supports are a lattice grid design SG-SGMP-17-20 Jtrne 2017 Revision 0 Page 5 of 19

2.0 180 Day Steam Generator Tube Inspection Report In accordance with WBNI Technical Specification Section 5.7.2.12, "Steam Generator Program", and Technical Specification Section 5.9.9, "Steam Generator Tube Inspection Report", this report documents the scope and results of the UlR14 SG inspections. There are eight specific reporting requirements associated with the Technical Specification. Each lettered reporting requirement listed below is followed with the associated infonnation based on the inspections performed during U1R14.

a. The Scope of the Inspections Performed on Each SG The UlRl4 outage included a combination of bobbin and array coil inspections of 100% of the full length in all in-service tubes except for tubes in Rows I through 4. Tube Rows I through 4 were inspected to the frst support with the combination bobbin and array coil from both the hot leg tube end (HTE) and the cold leg tube end (CTE). The remainder of the tube length in Rows I through 4 were inspected with a singular bobbin probe due to dimensional clearance restrictions in the U-bend region. As a result, the inspection included all tubes with prior indications of degradation and all tubes not inspected during the previous SG in-service inspection. The table below summarizes the number and type of eddy current examinations performed during UlR14.

Table 2-1: Watts Bar U1R14 Steam Generator Eddy Current Inspection Scope Eddy Current Exam TVpe sGl sG2 sG3 sG4 Total 0.610 tIL Bobbin & Array VS3-HTE 5,125 5,123 5,121 5,114 20,483 0.610 CL Bobbin & Array VS3-CTE 5,125 5,123 5,121 5,114 20,483 0.590 HLICL Bobbin (U-bend Region) t27 t27 t27 t27 s08 In addition to the eddy current inspections, visual inspections were also performed on both the primary and secondary sides. Primary side visual inspections included all previously installed tube plugs, the channel head bowl cladding, and the divider plate. Secondary side visual inspections were performed at the top of the tubesheet for the detection of foreign objects, assessment of hard deposit buildup in the tube bundle interior 'kidney region' and for determining the effectiveness of the tubesheet cleaning performed in all four SGs.

b. Active Degradation Mechanisms Found Volumetric wear was the only degradation mechanism detected during the UlRl4 inspection. All of the wear indications detected were located at either U-bend or horizontal tube support structures. Table 2-2 below shows the number of indications reported during the UlR14 inspection.

Table2-22 Number of Indications Detected for Each Degradation Mechanism Degradation Mechanism scl1 sG12 sG13 SGl4 Total U-bend Support Stmcnre Wear l3 lt 23 t2 59 Horizontal Tube Support Grid Wear 74 139 83 t23 419

c. Nondestructive Examination (NDE) Techniques Used for Each Degradation Mechanism Table 2-3 below provides the NDE techniques that were used for the detection of each degradation mechanism that was considered as existing or potential for the UlRl4 inspection.

SG-SGMP-17-20 Jtrne 2017 Revision 0 Page 6 of 19

Table 2-3: I\DE Techniques for Each Existing or Potential Degradation Mechanism Degradation Mechanism Detection Technique EPRI ETSS Bobbin 96004.1, Revision l3 Array I 1956. l, Revision 2 U-Bend Array 11956.2, Revision 2 Support Stmcture Wear Array I 1956.3, Revision 2 Array 11956.4. Revision2 Bobbin 96004.1, Revision l3 Array I 1956.1, Revision 2 Horizontal Array 11956.2, Revision2 Tube Support Grid Wear Array I1956.3, Revision2 Array 11956.4. Revision2 Bobbin 27091.2, Revision 2 Array I 1956.1, Revision 2 Foreign Object Wear Array 11956.2, Revision 2 Array I1956.3, Revision 2 Array 11956.4. Revision2 Tube-to-Tube Wear Bobbin 96010.1, RevisionT

d. Location, Orientation (if Linear), and Measured Sizes (if Available) of Service Induced Indications Table 2-4 through 2-8 below provides a listing of all service-induced indications reported during the UlRl4 inspection including the estimated depths from the bobbin coil.

Table 24: lVatts Bar U1R14 U-bend Support Structure Wear fndications - All SGs SG Row Col Locn Inchl Ind YuTW Characterization Resolution I 53 74 VS4 l. t5 PCT l5 U-bend Support Stnrcnre Wear Remain In-Service I 58 47 VS3 1.29 PCT l6 U-bend Support Structure Wear Remain In-Service I 58 47 VS3 -0.96 PCT l6 U-bend Support Structure Wear Remain In-Service I 66 65 V54 0.86 PCT r9 U-bend Support Structure Wear Remain In-Service I 77 56 VS3 -0.9r PCT l8 U-bend Support Structure Wear Remain In-Service I 77 82 VS3 t.t2 PCT t7 U-bend Support Stnrcture Wear Remain In-Senrice I 82 83 VS4 I.0r PCT t8 U-bend Support Structure Wear Remain In-Service I 95 58 VS2 -0.61 PCT l5 U-bend Support Structure Wear Remain In-Service I 105 68 DS2 0.62 PCT 2t U-bend Support Stnrcture Wear Remain In-Service I 105 68 VS2 -0.03 PCT l9 U-bend Support Stnrcture Wear Remain In-Service I 105 68 VS2 -0.72 PCT l8 U-bend Support Structure Wear Remain In-Service I r05 68 VS4 1.03 PCT l7 U-bend Support Stnrcture Wear Remain In-Service I 105 68 DS2 -0.23 PCT l5 U-bend Support Structure Wear Remain In-Service 2 65 98 VS2 t.24 PCT t7 U-bend Support Structure Wear Remain In-Service 2 67 96 VS2 1.05 PCT t4 U-bend Support Structure Wear Remain In-Service 2 75 54 VS4 0.86 PCT 22 U-bend Support Structure Wear Remain In-Service 2 90 67 VS4 -0.76 PCT l8 U-bend Support Stnrcture Wear Remain In-Service 2 90 67 VS2 -0.85 PCT t2 U-bend Support Stnrcture Wear Remain In-Service 2 9l 58 vs2 0.8 PCT 20 U-bend Support Stnrcture Wear Remain In-Service 2 96 63 VS3 -0.64 PCT 22 U-bend Support Stnrcture Wear Remain In-Service 2 99 s8 VS4 0.8 PCT l8 U-bend Support Stmcture Wear Remain In-Service 2 r00 63 VS2 -0.75 PCT 24 U-bend Support Stnrcture Wear Remain In-Service 2 100 63 VS2 0.55 PCT l8 U-bend Support Stnrcture Wear Remain In-Service 2 l0l 52 vst -0.93 PCT t3 U-bend Support Stnrcture Wear Remain In-Service SG-SGMP-17-20 June 2017 Revision 0 Page 7 of 19

SG Row Col Locn Inchl Ind o/oTW Characterization Resolution '

3 24 69 DS4 -0.03 PCT 23 U-bend Support Stnrcture Wear Remain In-Service 3 43 78 VS3 1.2 PCT t6 U-bend Support Stnrcture Wear Remain In-Service 3 50 85 vs3 -0.38 PCT 20 U-bend Support Structure Wear Remain In-Service 3 53 82 VS3 -0.12 PCT t9 U-bend Support Structure Wear Remain In-Service 3 63 82 VS3 1.35 PCT t7 U-bend Support Stnrcture Wear Remain In-Service 3 & 8l VS3 1.82 PCT l7 U-bend Support Stnrcture Wear Remain In-Service 3 8l 56 VS4 0.89 PCT 27 U-bend Support Structure Wear Remain In-Service 3 82 43 VS2 -0.95 PCT l8 U-bend Support Structure Wear Remain In-Service 3 96 67 VS2 -0.78 PCT l6 U-bend Support Structure Wear Remain In-Service 3 97 56 VS3 0.74 PCT 20 U-bend Support Structure Wear Remain In-Service 3 97 56 VS3 t.2l PCT l9 U-bend Support Stnrcture Wear Remain In-Service 3 97 @ DS3 -0.83 PCT t9 U-bend Support Structure Wear Remain In-Service 3 98 7l VS4 0.t3 PCT 20 U-bend Support Stnrcture Wear Remain In-Service 3 99 50 DS3 0.82 PCT l8 U-bend Support Structure Wear Remain In-Service 3 99 58 VS4 0.96 PCT 2t U-bend Support Structure Wear Remain In-Service 3 99 s8 V34 0.03 PCT l7 U-bend Support Structure Wear Remain In-Service 3 r00 55 VS2 -0.75 PCT 20 U-bend Support Stnrcture Wear Remain In-Service 3 100 63 DS3 0.8 PCT t7 U-bend Support Structure Wear Remain In-Service 3 100 67 DS3 0.7 5 PCT l8 U-bend Support Stnrcture Wear Remain In-Service 3 r0l 58 DS2 -0.8 PCT 2t U-bend Support Stnrcture Wear Remain In-Service 3 l0l 58 VS4 0.84 PCT t9 U-bend Support Structure Wear Remain In-Service 3 l0l 58 VS3 -0.31 PCT t7 U-bend Support Structure Wear Remain In-Service 3 102 73 VSI -0.91 PCT l9 U-bend Support Stmcture Wear Remain In-Service 4 92 8l VS2 0.9 PCT 23 U-bend Support Structure Wear Remain In-Service 4 93 70 VS2 0.92 PCT 19 U-bend Support Stnrcture Wear Remain In-Service 4 93 70 VS2 0.06 PCT l8 U-bend Support Stnrcture Wear Remain In-Service 4 93 70 VS2 -0.82 PCT l8 U-bend Support Structure Wear Remain In-Service 4 93 80 vs2 0.96 PCT 2t U-bend Support Structure Wear Remain In-Service 4 93 80 vs2 0.2 PCT t7 U-bend Support Stnrcture Wear Remain In-Service 4 96 83 DS2 -0.83 PCT 20 U-bend Support Structure Wear Remain In-Service 4 97 72 VS3 -0.24 PCT l8 U-bend Support Stmcture Wear Remain In-Service 4 98 47 VS2 0.82 PCT l5 U-bend Support Structure Wear Remain In-Service 4 l0l 70 VS3 0.61 PCT t9 U-bend Support Structure Wear Remain In-Service 4 102 57 VS3 t.t4 PCT 22 U-bend Support Stnrcture Wear Remain In-Service 4 102 57 DS2 -0.76 PCT 2t U-bend Support Structure Wear Remain In-Service SG-SGMP-17-20 June 2017 Revision 0 Page 8 of 19

Table 2-5: Watts Bar U1R14 Ilorizontal Tube Support Grid Wear Indications - SG I SG Row Col Locn Inchl Ind (%rw Characterization Resolution I I 48 H04 1.06 PCT l8 Horizontal Grid Wear Remain In-Service I I 48 H07 0. l9 PCT l7 Horizontal Grid Wear Remain In-Service I I I l6 c04 -0.88 PCT l8 Horizontal Grid Wear Remain In-Service 1 7 64 H09 0.66 PCT t9 Horizontal Grid Wear Remain In-Service I 7 88 H06 -0.97 PCT 22 Horizontal Grid Wear Remain In-Service I 7 102 H08 0.63 PCT l8 Horizontal Grid Wear Remain In-Service I 8 99 H09 1.06 PCT t9 Horizontal Grid Wear Remain In-Service I 8 tzt c05 -0.67 PCT l7 Horizontal Grid Wear Remain In-Service I 9 100 cl0 -0.87 PCT t9 Horizontal Grid Wear Remain In-Service I 9 100 cll 0.76 PCT l8 Horizontal Grid Wear Remain In-Service I 9 104 H07 -0.92 PCT 22 Horizontal Grid Wear Remain In-Service I l8 103 H07 -0.92 PCT 20 Horizontal Grid Wear Remain In-Service I 23 84 clr 0.78 PCT l9 Horizontal Grid Wear Remain In-Service I 26 t23 c06 -0.7 PCT r9 Horizontal Grid Wear Remain In-Service I 27 124 c06 -0.84 PCT 20 Horizontal Grid Wear Remain In-Service I 28 45 clr 0.67 PCT t9 Horizontal Grid Wear Remain In-Service I 29 t24 c06 0.77 PCT 20 Horizontal Grid Wear Remain In-Service I 29 t24 c0s -0.9 PCT t7 Horizontal Grid Wear Remain In-Service I 34 t23 c05 -0.87 PCT t9 Horizontal Grid Wear Remain In-Service I 59 n2 c06 -0.67 PCT t7 Horizontal Grid Wear Remain In-Service I 60 ll5 c0s -0.67 PCT l8 Horizontal Grid Wear Remain In-Service I 67 tt2 c06 0.83 PCT t9 Horizontal Grid Wear Remain In-Service I 68 lll c06 0.75 PCT l8 Horizontal Grid Wear Remain In-Service I 7l ll0 c06 0.81 PCT t9 Horizontal Grid Wear Remain In-Service I 76 t07 c06 0.62 PCT 22 Horizontal Grid Wear Remain In-Service I 77 106 c06 0.72 PCT l8 Horizontal Grid Wear Remain In-Service I 79 104 c03 -0,84 PCT t7 Horizontal Grid Wear Remain In-Service I 82 103 c04 -0.7 4 PCT l5 Horizontal Grid Wear Remain In-Service I 83 26 c03 0.73 PCT l9 Horizontal Grid Wear Remain In-Service I 83 r02 c03 -0.76 PCT l9 Horizontal Grid Wear Remain In-Service I 83 t02 c06 0.67 PCT l7 Horizontal Grid Wear Remain In-Service I 84 99 c04 0.75 PCT 22 Horizontal Grid Wear Remain In-Service I 84 99 c03 -0.76 PCT l9 Horizontal Grid Wear Remain In-Service I 84 99 c07 I PCT l8 Horizontal Grid Wear Remain In-Service I 85 30 c03 0.73 PCT 2l Horizontal Grid Wear Remain In-Service I 85 94 c03 I PCT l8 Horizontal Grid Wear Remain In-Service I 85 98 c04 0.81 PCT l8 Horizontal Grid Wear Remain In-Service I 85 100 c03 -0.79 PCT 27 Horizontal Grid Wear Remain In-Service I 86 97 c04 0.56 PCT t7 Horizontal Grid Wear Remain In-Service I 86 99 c03 -0.9 PCT l8 Horizontal Grid Wear Remain In-Service 1 87 30 c02 0.73 PCT 2l Horizontal Grid Wear Remain In-Service I 87 96 c04 -0.87 PCT l9 Horizontal Grid Wear Remain In-Service 1 87 98 c03 0.76 PCT 2l Horizontal Grid Wear Remain In-Service I 88 3l c03 0.78 PCT t7 Horizontal Grid Wear Remain In-Service I 88 95 c03 -0.87 PCT 22 Horizontal Grid Wear Remain In-Service I 88 97 c03 0.78 PCT 2t Horizontal Grid Wear Remain In-Service SG-SGMP-17-20 June 2017 Revision 0 Page 9 of 19

I 89 94 c04 0.73 PCT l8 Horizontal Grid Wear Remain In-Service I 89 96 c03 -0.t9 PCT 33 Horizontal Grid Wear Remain In-Service I 90 93 c03 -0.75 PCT 20 Horizontal Grid Wear Remain In-Service I 90 95 c04 0.59 PCT 22 Horizontal Grid Wear Remain In-Service I 90 95 c03 -0.78 PCT 2t Horizontal Grid Wear Remain In-Service I 9l 90 c04 -0.98 PCT t9 Horizontal Grid Wear Remain In-Service I 9l 92 c03 -0.9 PCT l9 Horizontal Grid Wear Remain In-Service I 9l 94 c06 0.64 PCT 20 Horizontal Grid Wear Remain In-Service I 92 9l c03 -0.9 PCT l8 Horizontal Grid Wear Remain In-Service I 92 93 c03 -0.79 PCT 24 Horizontal Grid Wear Remain In-Service I 95 88 c03 0.7 5 PCT 22 Horizontal Grid Wear Remain In-Service I 96 89 c03 -0.93 PCT l8 Horizontal Grid Wear Remain In-Service I 97 84 c07 0.78 PCT 2t Horizontal Grid Wear Remain In-Service I 97 84 c03 -0.79 PCT 20 Horizontal Grid Wear Remain In-Service I 98 85 c05 -0.92 PCT 22 Horizontal Grid Wear Remain In-Service I 98 85 c03 0.73 PCT 20 Horizontal Grid Wear Remain In-Service I 100 83 c05 -0.95 PCT 23 Horizontal Grid Wear Remain In-Service I 100 83 c03 0.75 PCT 22 Horizontal Grid Wear Remain In-Service I t0l 66 c03 0.78 PCT l7 Horizontal Grid Wear Remain In-Service I l0l 78 c03 -0.95 PCT 20 Horizontal Grid Wear Remain In-Service I 102 7l c03 -0.8 r PCT t7 Horizontal Grid Wear Remain In-Service 1 102 7l c04 I PCT l6 Horizontal Grid Wear Remain In-Service I 102 79 c03 0.73 PCT 23 Horizontal Grid Wear Remain In-Service I 103 54 c03 0.9s PCT l8 Horizontal Grid Wear Remain In-Service I 103 74 c03 0.95 PCT l8 Horizontal Grid Wear Remain In-Service I 104 63 c03 0.78 PCT t8 Horizontal Grid Wear Remain In-Service I 105 64 c05 -0.92 PCT 22 Horizontal Grid Wear Remain In-Service I 105 64 c03 0.7 5 PCT 20 Horizontal Grid Wear Remain In-Service SG-SGMP-17-20 June 2017 Revision 0 Page l0 of 19

aDte 2{:

Table wa Bar U1R14 Horizontal z-oz Watts o n u Suooort Grid Wear Tube ear Inorcauons Indications -

- SG 2 SG Row Col Locn Inchl Ind o/oTW Characterization Resolution 2 I 42 H04 -0.8 PCT t6 Horizontal Grid Wear Remain In-Service 2 I 44 H08 -0.91 PCT t6 Horizontal Grid Wear Remain In-Service 2 I 44 H04 -0.86 PCT l3 Horizontal Grid Wear Remain In-Service 2 I 48 H04 0.91 PCT t7 Horizontal Grid Wear Remain In-Service 2 I 70 H05 -0.95 PCT l6 Horizontal Grid Wear Remain In-Service 2 I 74 H04 -0.6 PCT l8 Horizontal Grid Wear Remain In-Service 2 2 31 H06 -0.99 PCT l9 Horizontal Grid Wear Remain In-Service

) 2 4t H07 -0.94 PCT t7 Horizontal Grid Wear Remain In-Service 2 2 53 H0s -0.72 PCT l6 Horizontal Grid Wear Remain In-Service 2 2 69 H04 -0.94 PCT t7 Horizontal Grid Wear Remain In-Service

)

L 2 73 H04 -0.88 PCT l6 Horizontal Grid Wear Remain In-Service 2 2 l0l H06 0.86 PCT l7 Horizontal Grid Wear Remain In-Service 2 6 I c03 0.81 PCT l7 Horizontal Grid Wear Remain In-Senrice 2 8 I c03 0.56 PCT l8 Horizontal Grid Wear Remain In-Service 2 8 77 H08 -0.98 PCT 25 Horizontal Grid Wear Remain In-Service 2 8 77 H07 l.0l PCT 2t Horizontal Grid Wear Remain In-Service 2 8 t27 c04 0.82 PCT 22 Horizontal Grid Wear Remain In-Service 2 8 127 c03 0.76 PCT 2t Horizontal Grid Wear Remain In-Service 2 t0 t27 c03 0.75 PCT 2t Horizontal Grid Wear Remain In-Service 2 t4 t23 c03 0.92 PCT t7 Horizontal Grid Wear Remain In-Service 2 l8 73 H07 r.04 PCT l9 Horizontal Grid Wear Remain In-Service 2 t9 124 c05 -0.93 PCT l8 Horizontal Grid Wear Remain In-Service 2 l9 t24 c03 0,76 PCT t7 Horizontal Grid Wear Remain In-Service 2 t9 126 c03 0.79 PCT t7 Horizontal Grid Wear Remain In-Service 2 20 t23 c03 0.86 PCT l8 Horizontal Grid Wear Remain In-Service 2 2t t22 c09 1.04 PCT 20 Horizontal Grid Wear Remain In-Service 2 22 123 c03 0.73 PCT 30 Horizontal Grid Wear Remain In-Service 2 22 t23 c07 0.76 PCT 23 Horizontal Grid Wear Remain In-Service 2 22 r23 c07 -0.92 PCT 23 Horizontal Grid Wear Remain In-Service 2 22 t23 c05 0.64 PCT l8 Horizontal Grid Wear Remain In-Service 2 22 123 c06 1.07 PCT l8 Horizontal Grid Wear Remain In-Service 2 22 t25 c03 0.7 PCT 18 Horizontal Grid Wear Remain In-Service 2 22 t25 c06 0.73 PCT r8 Horizontal Grid Wear Remain In-Service 2 23 44 ct2 0.67 PCT 20 Horizontal Grid Wear Remain In-Service 2 23 48 ct2 -0.84 PCT t7 Horizontal Grid Wear Remain In-Service 2 23 t22 c03 0.76 PCT 22 Horizontal Grid Wear Remain In-Service

) 25 28 ct2 -0.79 PCT l3 Horizontal Grid Wear Remain In-Service 2 25 122 c03 0.76 PCT 23 Horizontal Grid Wear Remain In-Service 2 26 t23 c03 0.6s PCT 2t Horizontal Grid Wear Remain In-Service 2 26 123 CM 0.@ PCT l9 Horizontal Grid Wear Remain In-Service 2 26 t23 c03 -0.9s PCT l8 Horizontal Grid Wear Remain In-Service 2 26 t25 c03 0.t PCT l8 Horizontal Grid Wear Remain In-Service 2 27 4 c06 1.04 PCT l5 Horizontal Grid Wear Remain In-Service

) 27 t24 c03 0.8 r PCT 2t Horizontal Grid Wear Remain In-Service 2 27 124 c05 -0.98 PCT t9 Horizontal Grid Wear Remain In-Service

) 28 ll9 c06 -0.82 PCT 2t Horizontal Grid Wear Remain In-Service 2 28 t23 c03 0.78 PCT 26 Horizontal Grid Wear Remain In-Service SG-SGMP-17-20 June 2017 Revision 0 Page 11 of 19

SG Row Col Locn Inchl Ind YrTW Characterization Resolution 2 30 7 c06 0.76 PCT t6 Horizontal Grid Wear Remain In-Service 2 30 123 c06 0.84 PCT 27 Horizontal Grid Wear Remain In-Service 2 30 t23 c07 -0.86 PCT 27 Horizontal Grid Wear Remain In-Service 2 30 t23 c03 0.73 PCT 26 Horizontal Grid Wear Remain In-Service 2 30 t23 c05 -0.89 PCT 23 Horizontal Grid Wear Remain In-Service 2 30 123 c06 -0.84 PCT 20 Horizontal Grid Wear Remain In-Service 2 30 123 c04 0.65 PCT l8 Horizontal Grid Wear Remain In-Service 2 3r 54 ct2 1.03 PCT 22 Horizontal Grid Wear Remain In-Service 2 32 t2t c03 0.73 PCT t9 Horizontal Grid Wear Remain In-Service 2 32 t2t c05 -0.93 PCT l8 Horizontal Grid Wear Remain In-Service 2 33 t22 c03 -0.9 PCT l9 Horizontal Grid Wear Remain In-Service 2 33 122 c04 0.73 PCT l8 Horizontal Grid Wear Remain In-Service 2 33 122 c07 0.s3 PCT l8 Horizontal Grid Wear Remain In-Service 2 36 7 c06 -0.84 PCT l8 Horizontal Grid Wear Remain In-Service 2 36 t2t c03 -0.92 PCT 20 Horizontal Grid Wear Remain In-Service 2 37 8 c03 0.75 PCT l8 Horizontal Grid Wear Remain In-Service 2 38 7 c03 0.94 PCT t6 Horizontal Grid Wear Remain In-Service 2 39 8 c07 1.07 PCT t5 Horizontal Grid Wear Remain In-Service 2 47 l0 c03 0.88 PCT t9 Horizontal Grid Wear Remain In-Service 2 50 9 c04 -0.9 PCT l9 Horizontal Grid Wear Remain In-Service 2 5l ll8 c03 -0.98 PCT l8 Horizontal Grid Wear Remain In-Service 2 53 I l8 c03 -0.89 PCT 2t Horizontal Grid Wear Remain In-Service 2 s9 tt4 c04 0.62 PCT l5 Horizontal Grid Wear Remain In-Service 2 60 I 15 c03 -0.96 PCT l9 Horizontal Grid Wear Remain In-Service 2 60 ll5 c06 l.t2 PCT l9 Horizontal Grid Wear Remain In-Service 2 60 I l5 c07 l.0r PCT l7 Horizontal Grid Wear Remain In-Service 2 62 l5 c0s 0.67 PCT l9 Horizontal Grid Wear Remain In-Service 2 62 t5 c04 1.03 PCT l7 Horizontal Grid Wear Remain In-Service 2 62 ll3 c07 -0.98 PCT 25 Horizontal Grid Wear Remain In-Service 2 62 ll3 c03 -0.95 PCT l8 Horizontal Grid Wear Remain In-Service 2 62 n3 c04 0.62 PCT l8 Horizontal Grid Wear Remain In-Service 2 63 tt4 c03 1.04 PCT t7 Horizontal Grid Wear Remain In-Service 2 63 tt4 c06 0.64 PCT l5 Horizontal Grid Wear Remain In-Service 2 64 l13 c03 -0.87 PCT t7 Horizontal Grid Wear Remain In-Service 2 7l ll0 c05 0.65 PCT t6 Horizontal Grid Wear Remain In-Service 2 72 109 c03 -t.2 PCT 20 Horizontal Grid Wear Remain In-Service 2 76 107 c03 0.65 PCT l6 Horizontal Grid Wear Remain In-Service 2 77 104 c03 -0.76 PCT t9 Horizontal Grid Wear Remain In-Service 2 77 104 c04 I .01 PCT l8 Horizontal Grid Wear Remain In-Service 2 78 105 c03 -0.82 PCT l8 Horizontal Grid Wear Remain In-Service 2 79 IM c03 1.04 PCT l8 Horizontal Grid Wear Remain In-Service 2 79 104 c04 -0.96 PCT t7 Horizontal Grid Wear Remain In-Service 2 80 103 c06 -0.9s PCT l9 Horizontal Grid Wear Remain In-Service 2 83 100 c04 0.54 PCT 20 Horizontal Grid Wear Remain In-Service 2 85 100 c06 -0.99 PCT 2t Horizontal Grid Wear Remain In-Service 2 85 r00 c04 0.65 PCT l9 Horizontal Grid Wear Remain In-Service 2 85 100 c07 1.22 PCT l8 Horizontal Grid Wear Remain In-Service 2 86 97 c04 0.89 PCT l8 Horizontal Grid Wear Remain In-Service SG-SGMP-17-20 June 2017 Revision 0 Page 12 of 19

SG Row Col Locn Inchl Ind %TW Characterization Resolution 2 86 97 c03 0.68 PCT l7 Horizontal Grid Wear Remain In-Service 2 86 99 c04 0.7 PCT 22 Horizontal Grid Wear Remain In-Service 2 87 30 c03 0.74 PCT l8 Horizontal Grid Wear Remain In-Service 2 87 32 c06 1.72 PCT t9 Horizontal Grid Wear Remain In-Service 2 87 94 c04 0.73 PCT 20 Horizontal Grid Wear Remain In-Service 2 87 98 c06 -0.95 PCT 30 Horizontal Grid Wear Remain In-Service 2 87 98 c03 -0.9s PCT 23 Horizontal Grid Wear Remain In-Service 2 87 98 c04 0.67 PCT l9 Horizontal Grid Wear Remain In-Service 2 88 95 c03 1.04 PCT 37 Horizontal Grid Wear Remain In-Service 2 88 95 c03 0.53 PCT t6 Horizontal Grid Wear Remain In-Service 2 88 95 c06 0.78 PCT l6 Horizontal Grid Wear Remain In-Service 2 89 32 c03 -0.94 PCT t9 Horizontal Grid Wear Remain In-Service 2 89 32 c03 0.82 PCT l6 Horizontal Grid Wear Remain In-Senrice 2 89 94 c03 -0.98 PCT 25 Horizontal Grid Wear Remain In-Service 2 89 96 c06 1.04 PCT t7 Horizontal Grid Wear Remain In-Service 2 90 95 c04 0.73 PCT 23 Horizontal Grid Wear Remain In-Service 2 90 95 c07 -0.95 PCT l8 Horizontal Grid Wear Remain In-Service 2 9t 94 c03 -0.92 PCT 25 Horizontal Grid Wear Remain In-Service 2 92 35 c04 -0.86 PCT l7 Horizontal Grid Wear Remain In-Service 2 92 35 c03 -0.92 PCT l6 Horizontal Grid Wear Remain In-Service 2 92 93 c07 -0.87 PCT l9 Horizontal Grid Wear Remain In-Service 2 92 93 c04 0.73 PCT l8 Horizontal Grid Wear Remain In-Service 2 92 93 c06 -0.88 PCT l8 Horizontal Grid Wear Remain In-Service 2 95 82 c03 l.l5 PCT l7 Horizontal Grid Wear Remain In-Service 2 96 85 c06 0.89 PCT t9 Horizontal Grid Wear Remain In-Service 2 96 85 c07 1.06 PCT t7 Horizontal Grid Wear Remain In-Service 2 96 87 c03 -0.82 PCT t8 Horizontal Grid Wear Remain In-Service 2 97 86 c03 t.t2 PCT l9 Horizontal Grid Wear Remain In-Service

) 97 88 c03 -0.96 PCT 20 Horizontal Grid Wear Remain In-Service 2 98 43 c05 0.71 PCT 20 Horizontal Grid Wear Remain In-Service 2 98 79 c03 t.t2 PCT l9 Horizontal Grid Wear Remain In-Service 2 98 83 c03 l.l8 PCT l8 Horizontal Grid Wear Remain In-Service 2 99 84 c02 0.62 PCT l6 Horizontal Grid Wear Remain In-Service 2 100 8l c04 0.78 PCT 23 Horizontal Grid Wear Remain In-Service 2 l0l 78 c03 l.l5 PCT 20 Horizontal Grid Wear Remain In-Service 2 l0l 80 c03 1.2 PCT 20 Horizontal Grid Wear Remain In-Service 2 103 62 c03 0.92 PCT t7 Horizontal Grid Wear Remain In-Service 2 103 66 c05 0.67 PCT 22 Horizontal Grid Wear Remain In-Service 2 103 74 c03 l.l5 PCT l9 Horizontal Grid Wear Remain In-Service 2 104 6l c06 -0.9 PCT l6 Horizontal Grid Wear Remain In-Service 2 104 69 c05 0.7 PCT t9 Horizontal Grid Wear Remain In-Service 2 105 66 c03 0.72 PCT 23 Horizontal Grid Wear Remain In-Service 2 105 66 c05 0.67 PCT t7 Horizontal Grid Wear Remain In-Service 2 105 68 c03 0.75 PCT 20 Horizontal Grid Wear Remain In-Service SG-SGMP-17-20 June 2017 Revision 0 Page 13 of 19

Table2-72 UlRl4 Horimntal able 2-72 Watts Bar U1R14 Horizontal Tube Su Suooort Grid Wear tnotcauons ear Indications - SG 3 SG Row Col Locn Inchl Ind %TW Characterization Resolution 3 I 72 H04 -0.88 PCT l5 Horizontal Grid Wear Remain In-Service 3 I 72 H05 -0.96 PCT t4 Horizontal Grid Wear Remain In-Service 3 I 72 H04 0.91 PCT l3 Horizontal Grid Wear Remain In-Service 3 I 78 H04 -0.9r PCT 20 Horizontal Grid Wear Remain In-Service 3 I 86 H04 -0.85 PCT l5 Horizontal Grid Wear Remain In-Service 3 7 2 c03 0.83 PCT t6 Horizontal Grid Wear Remain In-Service 3 9 r06 c06 -0.78 PCT l8 Horizontal Grid Wear Remain In-Service 3 l0 I c03 0.72 PCT 23 Horizontal Grid Wear Remain In-Service 3 l0 I c05 -0.92 PCT t7 Horizontal Grid Wear Remain In-Service 3 l3 4 c03 0.75 PCT l8 Horizontal Grid Wear Remain In-Service 3 t4 5l Hl0 0.68 PCT l8 Horizontal Grid Wear Remain In-Service 3 t4 5l clt 1.06 PCT t7 Horizontal Grid Wear Remain In-Senrice 3 t4 8r H06 -0.9 PCT t8 Horizontal Grid Wear Remain In-Service 3 l5 2 c04 -0.97 PCT 20 Horizontal Grid Wear Remain In-Service 3 l5 2 c03 0.83 PCT t7 Horizontal Grid Wear Remain In-Service 3 l5 4 c06 -0.91 PCT l9 Horizontal Grid Wear Remain In-Service 3 t7 102 ct2 1.06 PCT 20 Horizontal Grid Wear Remain In-Service 3 t7 t02 cl2 0.66 PCT l8 Horizontal Grid Wear Remain In-Service 3 l8 53 ct2 -0.89 PCT t7 Horizontal Grid Wear Remain In-Service 3 l9 2 c04 -0.98 PCT 23 Horizontal Grid Wear Remain In-Service 3 20 6t cl0 -0.98 PCT l9 Horizontal Grid Wear Remain In-Service 3 23 t24 c06 0.69 PCT 23 Horizontal Grid Wear Remain In-Service 3 24 3 c05 0.8 PCT l8 Horizontal Grid Wear Remain In-Service 3 26 5 c03 -0.8 PCT l8 Horizontal Grid Wear Remain In-Service 3 28 I l9 ct2 -0.86 PCT l8 Horizontal Grid Wear Remain In-Service 3 32 5 c03 -0.89 PCT l8 Horizontal Grid Wear Remain In-Service 3 34 5 c03 I PCT 20 Horizontal Grid Wear Remain In-Service 3 53 r r8 c06 0.69 PCT l6 Horizontal Grid Wear Remain In-Service 3 59 t4 c03 1.03 PCT 2t Horizontal Grid Wear Remain In-Service 3 6t tt4 c06 0.83 PCT 26 Horizontal Grid Wear Remain In-Service 3 6l tt4 c06 -0.75 PCT t7 Horizontal Grid Wear Remain In-Service 3 64 l7 c03 -0.89 PCT l6 Horizontal Grid Wear Remain In-Service 3 64 lll c04 -0.77 PCT l8 Horizontal Grid Wear Remain In-Service 3 64 lll c07 I PCT t4 Horizontal Grid Wear Remain In-Service 3 65 l8 c03 -0.98 PCT l8 Horizontal Grid Wear Remain In-Service 3 67 n2 c06 l.l I PCT t6 Horizontal Grid Wear Remain In-Service 3 68 t9 c03 0.63 PCT l8 Horizontal Grid Wear Remain In-Service 3 7l r04 c03 0.87 PCT l7 Horizontal Grid Wear Remain In-Service 3 76 t07 c04 0.75 PCT 2t Horizontal Grid Wear Remain In-Service 3 76 t07 c06 0.8 PCT 20 Horizontal Grid Wear Remain In-Service 3 77 22 c03 0.72 PCT l6 Horizontal Grid Wear Remain In-Service 3 79 24 c03 0.75 PCT l8 Horizontal Grid Wear Remain In-Service 3 82 25 c03 0.69 PCT t6 Horizontal Grid Wear Remain In-Service 3 82 27 c03 0.67 PCT l6 Horizontal Grid Wear Remain In-Service 3 83 26 c03 0.95 PCT l5 Horizontal Grid Wear Remain In-Service 3 84 29 c03 0.72 PCT 20 Horizontal Grid Wear Remain In-Senrice 3 84 95 c05 0.91 PCT l6 Horizontal Grid Wear Remain In-Service SG-SGMP-17-20 June 2017 Revision 0 Page 14 of 19

SG Row Col Locn Inchl Ind o/oTW Characterization Resolution 3 84 99 c03 -0.92 PCT t7 Horizontal Grid Wear Remain In-Service 3 85 28 c03 0.7s PCT 2t Horizontal Grid Wear Remain In-Service 3 85 96 c03 0.8 PCT l8 Horizontal Grid Wear Remain In-Service 3 85 98 c02 -0.94 PCT 22 Horizontal Grid Wear Remain In-Service 3 86 3l c03 0.66 PCT t7 Horizontal Grid Wear Remain In-Service 3 86 95 c03 0.7 l PCT 20 Horizontal Grid Wear Remain In-Service 3 86 97 c02 -0.82 PCT 22 Horizontal Grid Wear Remain In-Service 3 86 99 c05 0.74 PCT 22 Horizontal Grid Wear Remain In-Service 3 86 99 c02 -0.85 PCT 2t Horizontal Grid Wear Remain In-Service 3 86 99 c04 0.62 PCT l8 Horizontal Grid Wear Remain In-Service 3 86 99 c03 -0.89 PCT t7 Horizontal Grid Wear Remain In-Service 3 89 32 c03 0.69 PCT l8 Horizontal Grid Wear Remain In-Service 3 89 96 c03 -0.92 PCT 22 Horizontal Grid Wear Remain In-Servrce 3 90 33 c03 0.66 PCT 2t Horizontal Grid Wear Remain In-Service 3 90 93 c04 -0.97 PCT l5 Horizontal Grid Wear Remain In-Service 3 90 95 c04 -0.8s PCT t8 Horizontal Grid Wear Remain In-Service 3 90 95 c03 -0.8 PCT l7 Horizontal Grid Wear Remain In-Service 3 9t 34 c03 -0.92 PCT 25 Horizontal Grid Wear Remain In-Service 3 92 35 c03 -0.98 PCT 25 Horizontal Grid Wear Remain In-Service 3 92 9l c03 -0.83 PCT l9 Horizontal Grid Wear Remain In-Service 3 92 9l c0s -0.95 PCT t6 Horizontal Grid Wear Remain In-Service 3 92 93 c04 -0.98 PCT t7 Horizontal Grid Wear Remain In-Service 3 93 36 c03 -0.89 PCT l8 Horizontal Grid Wear Remain In-Service 3 93 36 c04 0.69 PCT 18 Horizontal Grid Wear Remain In-Service 3 93 90 c03 0.8 PCT l9 Horizontal Grid Wear Remain In-Service 3 94 37 c06 -0.92 PCT t9 Horizontal Grid Wear Remain In-Service 3 94 4t c07 t.t2 PCT 21 Horizontal Grid Wear Remain In-Service 3 94 89 c03 -0.92 PCT l8 Horizontal Grid Wear Remain In-Service 3 95 38 c02 -0.77 PCT l9 Horizontal Grid Wear Remain In-Service 3 95 38 c04 0.69 PCT t7 Horizontal Grid Wear Remain In-Service 3 96 85 c06 0.79 PCT 19 Horizontal Grid Wear Remain In-Service 3 97 40 c04 0.72 PCT t6 Horizontal Grid Wear Remain In-Service 3 97 42 c04 0.69 PCT 26 Horizontal Grid Wear Remain In-Service 3 97 42 c06 0.86 PCT t6 Horizontal Grid Wear Remain In-Service 3 100 75 c03 0.72 PCT l8 Horizontal Grid Wear Remain In-Service 3 t0l 68 c03 0.8 PCT 2l Horizontal Grid Wear Remain In-Service SG-SGMP-17-20 June 2017 Revision 0 Page 15 of 19

aDte l-IJi 2-8 w warfstts lrar ull(rlt rlo Ba U1Rl4 a

H rUZO n tal T u be Su rt Grid Wear Indications - SG 4 SG Row Col Locn Inchl Ind o/oTW Characterization Resolution 4 3 42 cil -0.96 PCT 23 Horizontal Grid Wear Remain In-Service 4 3 42 ct2 1.09 PCT l9 Horizontal Grid Wear Remain In-Service 4 6 37 cll I .01 PCT t7 Horizontal Grid Wear Remain In-Service 4 6 73 H07 -0.87 PCT 2l Horizontal Grid Wear Remain In-Service 4 6 127 c03 0.76 PCT 23 Horizontal Grid Wear Remain In-Service 4 9 40 cll -0.96 PCT t7 Horizontal Grid Wear Remain In-Service 4 9 42 H06 0.62 PCT 24 Horizontal Grid Wear Remain In-Service 4 9 42 H07 0.72 PCT t7 Horizontal Grid Wear Remain In-Service 4 l0 4t c09 -0.87 PCT t9 Horizontal Grid Wear Remain In-Service 4 l0 6l H07 t.t2 PCT l8 Horizontal Grid Wear Remain In-Service 4 t2 7l H06 -0.86 PCT 22 Horizontal Grid Wear Remain ln-Service 4 t2 7l H07 -t.23 PCT 22 Horizontal Grid Wear Remain In-Service 4 l3 78 cl0 0.64 PCT 3l Horizontal Grid Wear Remain In-Service 4 t4 3 c04 0.69 PCT 20 Horizontal Grid Wear Remain In-Service 4 r8 63 ct2 0.61 PCT 23 Horizontal Grid Wear Remain In-Service 4 l8 63 cll 0.64 PCT 2t Horizontal Grid Wear Remain In-Service 4 22 123 c03 l.l PCT l8 Horizontal Grid Wear Remain In-Service 4 23 t24 c03 -0.88 PCT 2t Horizontal Grid Wear Remain In-Service 4 23 r24 c06 -0.84 PCT 2t Horizontal Grid Wear Remain In-Service 4 24 9l H06 -0.22 PCT t9 Horizontal Grid Wear Remain In-Service 4 24 125 c03 0.87 PCT 24 Horizontal Grid Wear Remain In-Service 4 24 t25 c06 0.75 PCT l8 Horizontal Grid Wear Remain In-Service 4 25 62 cll 0.67 PCT 20 Horizontal Grid Wear Remain In-Service 4 26 3s ct2 -0.92 PCT t7 Horizontal Grid Wear Remain In-Service 4 26 t23 c04 0.7 6 PCT 2t Horizontal Grid Wear Remain In-Service 4 26 123 c08 -0.93 PCT l9 Horizontal Grid Wear Remain In-Service 4 26 123 c03 -0.9 PCT l8 Horizontal Grid Wear Remain In-Service 4 27 124 c03 -0.93 PCT 23 Horizontal Grid Wear Remain In-Service 4 28 123 c04 -0.87 PCT 20 Horizontal Grid Wear Remain In-Service 4 30 5 c05 -0.78 PCT l8 Horizontal Grid Wear Remain In-Service 4 3l 124 c03 -0.93 PCT 20 Horizontal Grid Wear Remain In-Service 4 32 5 c02 0.76 PCT t7 Horizontal Grid Wear Remain In-Service 4 32 7 c02 0.82 PCT 20 Horizontal Grid Wear Remain In-Service 4 32 7 c03 0.73 PCT l8 Horizontal Grid Wear Remain In-Service 4 33 8 c03 0.94 PCT l8 Horizontal Grid Wear Remain In-Service 4 3s t22 c03 0.97 PCT 20 Horizontal Grid Wear Remain In-Service 4 43 8 c04 0.98 PCT l9 Horizontal Grid Wear Remain In-Service 4 44 9 c06 -0.7 PCT l8 Horizontal Grid Wear Remain In-Service 4 44 t2t c03 I PCT 22 Horizontal Grid Wear Remain In-Service 4 45 8 c03 -0.82 PCT r8 Horizontal Grid Wear Remain In-Service 4 49 il0 ct2 -0.48 PCT l8 Horizontal Grid Wear Remain In-Service 4 50 87 H0l -t.22 PCT l9 Horizontal Grid Wear Remain In-Service 4 53 r l8 c02 -0.87 PCT 2l Horizontal Grid Wear Remain In-Service 4 60 I 15 c07 0.9 PCT 18 Horizontal Grid Wear Remain In-Service 4 63 tt4 c06 l.l I PCT 2l Horizontal Grid Wear Remain In-Service 4 6s tt2 c05 -0.84 PCT t9 Horizontal Grid Vlear Remain In-Servrce 4 7t 108 c06 0.73 PCT t6 Horizontal Grid Wear Remain In-Service SG-SGMP-17-20 June 2017 Revision 0 Page 16 of 19

SG Row Col Locn Inchl Ind o/oTW Characterization Resolution 4 77 104 c03 0.71 PCT 26 Horizontal Grid Wear Remain In-Service 4 78 103 c03 0.8 PCT t8 Horizontal Grid Wear Remain In-Service 4 83 98 c03 0.71 PCT l8 Horizontal Grid Wear Remain In-Service 4 83 98 c04 -0.9 PCT t6 Horizontal Grid Wear Remain In-Service 4 83 100 c03 0.72 PCT 20 Horizontal Grid Wear Remain In-Service 4 84 97 c04 -0.94 PCT 20 Horizontal Grid Wear Remain In-Service 4 84 97 c03 0.74 PCT l9 Horizontal Grid Wear Remain In-Service 4 84 l0l c04 -0.94 PCT 22 Horizontal Grid Wear Remain In-Service 4 84 l0l c03 0.71 PCT 2t Horizontal Grid Wear Remain In-Senrice 4 84 l0r c02 0.68 PCT 20 Horizontal Grid Wear Remain In-Service 4 84 l0l c06 -0.91 PCT l8 Horizontal Grid Wear Remain In-Service 4 85 28 c03 -0.86 PCT 22 Horizontal Grid Wear Remain In-Service 4 85 94 c03 -0.84 PCT 20 Horizontal Grid Wear Remain In-Service 4 85 96 c04 -0.95 PCT t8 Horizontal Grid Wear Remain In-Service 4 85 100 c04 -0.86 PCT 20 Horizontal Grid Wear Remain In-Service 4 87 92 CM 0.78 PCT r9 Horizontal Grid Wear Remain In-Service 4 87 96 c03 -0.89 PCT 24 Horizontal Grid Wear Remain In-Service 4 87 96 c05 -0.72 PCT t9 Horizontal Grid Wear Remain In-Service 4 87 98 c04 -0.89 PCT 20 Horizontal Grid Wear Remain In-Service 4 88 3l c03 -0.95 PCT 22 Horizontal Grid Wear Remain In-Service 4 88 95 c03 -0.75 PCT t7 Horizontal Grid Wear Remain In-Service 4 89 94 c0s 0.66 PCT t7 Horizontal Grid Wear Remain In-Service 4 89 96 c03 -0.89 PCT 23 Horizontal Grid Wear Remain In-Service 4 89 96 c05 0.7 l PCT l8 Horizontal Grid Wear Remain In-Service 4 90 35 c03 I .18 PCT l9 Horizontal Grid Wear Remain In-Service 4 90 39 c04 0.88 PCT l7 Horizontal Grid Wear Remain In-Service 4 90 9l c04 -0.92 PCT l8 Horizontal Grid Wear Remain In-Service 4 9l 34 c03 -0.89 PCT 24 Horizontal Grid Wear Remain In-Service 4 9t 34 c05 0.74 PCT 20 Horizontal Grid Wear Remain In-Service 4 9l 36 c04 0.7 t PCT 22 Horizontal Grid Wear Remain In-Service 4 9l 36 c03 -t.2 PCT 2l Horizontal Grid Wear Remain In-Service 4 9l 38 c03 -0.92 PCT 22 Horizontal Grid Wear Remain In-Service 4 9l 92 c04 -0.8 PCT 20 Horizontal Grid Wear Remain In-Service 4 9l 94 c03 0.71 PCT 23 Horizontal Grid Wear Remain In-Service 4 92 37 c03 -0.86 PCT 25 Horizontal Grid Wear Remain In-Service 4 92 9l c03 0.65 PCT t7 Horizontal Grid Wear Remain In-Service 4 92 93 c03 0.74 PCT 20 Horizontal Grid Wear Remain In-Service 4 93 36 c03 -0.t 4 PCT 22 Horizontal Grid Wear Remain In-Service 4 93 36 c05 0.68 PCT 2t Horizontal Grid Wear Remain In-Service 4 94 37 c03 t.l7 PCT 34 Horizontal Grid Wear Remain In-Service 4 94 39 c03 -0.86 PCT 22 Horizontal Grid Wear Remain In-Service 4 94 39 c07 -0.92 PCT l8 Horizontal Grid Wear Remain In-Service 4 94 4l c03 -0.92 PCT 23 Horizontal Grid Wear Remain In-Service 4 95 40 c0s 0.71 PCT l9 Horizontal Grid Wear Remain In-Service 4 95 40 c06 1.03 PCT l8 Horizontal Grid Wear Remain In-Service 4 95 42 c03 -0.83 PCT 26 Horizontal Grid Wear Remain In-Service 4 95 86 c03 0.68 PCT 24 Horizontal Grid Wear Remain In-Service 4 96 4t c03 0.7 l PCT 22 Horizontal Grid Wear Remain In-Service SG-SGMP-17-20 June 2017 Revision 0 Page 17 of 19

SG Row Col Locn Inchl Ind %TW Characterization Resolution 4 96 4l c0s -0.98 PCT l9 Horizontal Grid Wear Remain In-Service 4 96 43 c03 -0.95 PCT l9 Horizontal Grid Wear Remain In-Service 4 96 45 c03 -0.92 PCT 2l Horizontal Grid Wear Remain In-Service 4 96 8l c03 0.92 PCT l8 Horizontal Grid Wear Remain In-Service 4 97 42 c0s -0.97 PCT 22 Horizontal Grid Wear Remain In-Service 4 97 78 c03 0.8 r PCT 2l Horizontal Grid Wear Remain In-Service 4 97 86 c03 0.74 PCT 25 Horizontal Grid Wear Remain In-Service 4 97 88 c03 0.8 PCT 2t Horizontal Grid Wear Remain In-Service 4 97 88 c03 -0.74 PCT 18 Horizontal Grid V/ear Remain In-Service 4 97 88 c07 -0.86 PCT 18 Horizontal Grid Wear Remain In-Service 4 98 43 c07 0.77 PCT l9 Horizontal Grid Wear Remain In-Service 4 98 43 c03 -0.95 PCT l8 Horizontal Grid Wear Remain In-Service 4 98 45 c03 -0.94 PCT 30 Horizontal Grid Wear Remain In-Service 4 98 8l c03 0.59 PCT l8 Horizontal Grid Wear Remain In-Service 4 98 85 c03 0.7 l PCT 23 Horizontal Grid Wear Remain In-Service 4 99 4 c03 0.88 PCT t9 Horizontal Grid Wear Remain In-Service 4 99 44 c06 0.79 PCT t7 Horizontal Grid Wear Remain In-Service 4 99 44 c08 0.71 PCT l7 Horizontal Grid Wear Remain In-Service 4 99 46 c03 -0.89 PCT 22 Horizontal Grid Wear Remain In-Service 4 100 8r c03 0.7 PCT l8 Horizontal Grid Wear Remain In-Service 4 100 83 c03 -0.86 PCT 2t Horizontal Grid Wear Remain In-Service 4 100 83 c07 t.t7 PCT l8 Horizontal Grid Wear Remain In-Service 4 l0t 80 c03 0.7 PCT 20 Horizontal Grid Wear Remain In-Service 4 t02 49 c03 0.8 PCT 2l Horizontal Grid Wear Remain In-Service 4 r02 5l c04 0.78 PCT l9 Horizontal Grid Wear Remain In-Service 4 t02 79 c03 0.73 PCT l9 Horizontal Grid Wear Remain In-Service 4 103 76 c03 0.67 PCT 2t Horizontal Grid Wear Remain In-Service 4 104 7l c03 -0.9 PCT 23 Horizontal Grid Wear Remain In-Service

e. Number of Tubes Plugged During the Inspection Outage for Each Active Degradation Mechanism There were no tubes required to be plugged during the Watts Bar UlRl4 RSG in-service inspection. Table 2-9 below provides the numbers of tubes plugged for each degradation mechanism detected. This table also shows the numbers of tubes plugged before and after the UlRl4 outage as well as the percentage of tubes currently plugged.

Table 2-92 Number of Tubes Plugged for Each Degradation Mechanism sclr scr2 SG13 SG14 Total Plugged Tubes prior to UlRl4 3 5 7 t4 29 Plugged for U-bend Support Structure Wear 0 0 0 0 0 Plugged for Horizontal Grid Wear 0 0 0 0 0 Total Plugged to Date 3 5 7 t4 29 Percentage Plugged to Date 0.06% 0.t0% 0.r4% 0.274/0 a.r4%

SG-SGMP-17-20 June 2017 Revision 0 Page l8 of 19

f. Total Number and Percentage of Tubes Plugged to Date Table 2-9 in the previous section provides the number and percentage of tubes plugged to date.
g. The Results of Condition Monitoring, Including the Results of Tube Pulls and In-Situ Testing Tube Inteerity A condition monitoring (CM) assessment was performed as required by the WBNI steam generator progfam. The only tube degradation detected during the U1Rl4 inspection was wear at tube support structures. The deepest indication had an estimated depth of 37%Ttl from the bobbin probe exam and was located at a horizontal support grid. Conservatively assuming an enveloping flaw length slightly greater than the width of the support (2.0 inches), the CM limit for horizontal support grid wear is 52%TW. This CM limit includes uncertainties for material properties, NDE depth sizing, and the burst pressure relationship. Since the deepest flaw has an estimated depth less than the conservatively determined CM limit, the stnrctural integrity perfonnance criterion was met for the operating interval prior to UlR14.

Since volumetric wear indications will leak and burst at essentially the same pressure, accident-induced leakage integnty at a much lower accident pressure differential is also demonstrated.

Operational leakage integrity was demonstrated by the absence of any detectable primary-to-secondary leakage during the operating interval prior to UlRl4. Since tube integrity was demonstrated analytically, in-sitr,r pressure testing was not required nor perfonned during the UlRl4 outage. No tube pulls were planned or performed during UlRl4.

Visual Insoection Results Visual inspections were performed on both the primary and secondary sides during UlR14.

Primary side inspections included visual inspections of all previously installed tube plugs as well as the channel head bowl cladding and the divider plate. The installed tube plug inspections showed no conditions indicative of improper installation or in-service degradation. The visual inspections of the channel head bowl cladding and the divider plate showed no visually apparent evidence of degradation of the cladding, divider plate, or divider plate welds.

Prior to the secondary side foreign object search and retrieval (FOSAR) inspections, sludge, scale, foreign objects, and other deposit accumulations at the top of the tubesheet were removed as part of the top of tubesheet sludge lancing process. The secondary side FOSAR inspections performed in all four SGs included visual examination of tube bundle periphery tubes from the hot leg and cold leg annulus and center no tube lane. A total of 6 foreign objects were removed from the top of the tubesheet region and 6 objects remain on the secondary side among the four SGs. The foreign objects remaining are all small pieces of metal, wires, and bristles. Any foreign objects not able to be retrieved were characteized and an analysis performed to demonstrate acceptability of continued operation without exceeding the performance criteria. A limited top of tubesheet in-bundle visual inspection was also performed in each SG for the purpose ofassessing and frending the level ofhardened deposit buildup in the kidney regron.

h. The Effective Plugging Percentage for All Plugging in Each SG There are no sleeves installed in the WBN1 replacement SGs. Therefore, the effective plugging percentage is the same as the plugging percentage shown in Table 2-9.

SG-SGMP-17-20 June 2017 Revision 0 Page 19 of 19