Duke Energy Carolinas, LLC Oconee Nuclear Station, Units 1, 2, and 3 Renewed Operating Licenses: DPR-38, DPR-47, and DPR-55 Docket Numbers: 50-269, 50-270, and 50-287 Registration for Use of General License Spent Fuel Cask Number 130 In accordance with 1OCFR72.212 (b)(2), Duke Energy Carolinas, LLC, hereby notifies the Commission of storage of dry fuel under Cask Certificate of Compliance 72-1004, Amendment 9. The date of storage was July 26, 2013, and the cask load number was 130.
Duke Energy Carolinas, LLC Oconee Nuclear Station, Units 1, 2, and 3 Renewed Operating Licenses: DPR-38, DPR-47, and DPR-55 Docket Numbers: 50-269, 50-270, and 50-287 Registration for Use of General License Spent Fuel Cask Number 130 In accordance with 10CFR72.212 (b)(2), Duke Energy Carolinas, LLC, hereby notifies the Commission of storage of dry fuel under Cask Certificate of Compliance 72-1004, Amendment 9. The date of storage was July 26, 2013, and the cask load number was 130.
The cask model is the Standardized NUHOMS 24PHB and the dry storage canister identification number is ONS-24PHBL-HZ130. The physical storage location at Oconee Nuclear Station's Independent Spent Fuel Storage Installation is Module W-60.
The cask model is the Standardized NUHOMS 24PHB and the dry storage canister identification number is ONS-24PHBL-HZ130. The physical storage location at Oconee Nuclear Station's Independent Spent Fuel Storage Installation is Module W-60.
If there are any questions regarding this registration, please contact Corey A. Gray, Oconee Regulatory Affairs Group, at (864) 873-6325.
If there are any questions regarding this registration, please contact Corey A. Gray, Oconee Regulatory Affairs Group, at (864) 873-6325.

Latest revision as of 12:09, 11 November 2019

Registration for Use of General License Spent Fuel Cask Number 130
ML13241A300
Person / Time
Site: Oconee, 07201004  Duke Energy icon.png
Issue date: 08/26/2013
From: Batson S
Duke Energy Carolinas
To:
Document Control Desk, NRC/NMSS/SFPO
References
Download: ML13241A300 (2)


Text

DUKE

~ FMDC~VVice President Oconee Nuclear Station Duke Energy ONO IVP / 7800 RochesterHwy Seneca, SC 29872 864-873-3274 864-873-4208 fax Scott.Batson@duke-energy.com 10 CFR 72.212 August 26, 2013 Document Control Desk Director, Spent Fuel Project Office Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

Subject:

Duke Energy Carolinas, LLC Oconee Nuclear Station, Units 1, 2, and 3 Renewed Operating Licenses: DPR-38, DPR-47, and DPR-55 Docket Numbers: 50-269, 50-270, and 50-287 Registration for Use of General License Spent Fuel Cask Number 130 In accordance with 10CFR72.212 (b)(2), Duke Energy Carolinas, LLC, hereby notifies the Commission of storage of dry fuel under Cask Certificate of Compliance 72-1004, Amendment 9. The date of storage was July 26, 2013, and the cask load number was 130.

The cask model is the Standardized NUHOMS 24PHB and the dry storage canister identification number is ONS-24PHBL-HZ130. The physical storage location at Oconee Nuclear Station's Independent Spent Fuel Storage Installation is Module W-60.

If there are any questions regarding this registration, please contact Corey A. Gray, Oconee Regulatory Affairs Group, at (864) 873-6325.

Sincerely, Scott L. Batson Vice President, Oconee Nuclear Station www.duke-energy.com

U. S. Nuclear Regulatory Commission August 26, 2013 Page 2 cc:

Mr. John P. Boska, Project Manager (by electronic distribution)

U.S. Nuclear Regulatory Commission One White Flint North, M/S O-8G9A 11555 Rockville Pike Rockville, MD 20852-2746 C. Haney, Director Office of Nuclear Material Safety and Safeguards U. S. Nuclear Regulatory Commission 11555 Rockville Pike Mail Stop EBB 1 Rockville, MD 20852-2738 M. D. Waters, Chief - Licensing Branch Office of Nuclear Material Safety and Safeguards U. S. Nuclear Regulatory Commission 11555 Rockville Pike Mail Stop E3 D2M Rockville, MD 20852-2738 Mr. Victor M.McCree, Administrator, Region II U.S. Nuclear Regulatory Commission Marquis One Tower 245 Peachtree Center Ave., NE, Suite 1200 Atlanta, GA 30303-1257 Robert P. Carrion, Division of Reactor Safety U. S. Nuclear Regulatory Commission Marquis One Tower 245 Peachtree Center Ave., NE Suite 1200 Atlanta, GA 30303-1257 Cecil A. Fletcher II,Division of Reactor Safety U. S. Nuclear Regulatory Commission Marquis One Tower 245 Peachtree Center Ave., NE Suite 1200 Atlanta, GA 30303-1257 Ed Crowe NRC Senior Resident Inspector Oconee Nuclear Station