(One intermediate revision by the same user not shown) |
Line 9: |
Line 9: |
| | docket = 07201031 | | | docket = 07201031 |
| | license number = | | | license number = |
| | contact person = White B H | | | contact person = White B |
| | case reference number = CAC 001028, EPID L-2018-LLA-0561 | | | case reference number = CAC 001028, EPID L-2018-LLA-0561 |
| | package number = ML19045A345 | | | package number = ML19045A345 |
Line 19: |
Line 19: |
|
| |
|
| =Text= | | =Text= |
| {{#Wiki_filter:Federal Register}} | | {{#Wiki_filter:March 24, 2019 Mr. Wren Fowler Licensing Manager NAC International 3930 East Jones Bridge Road Suite 200 Norcross, GA 30092 |
| | |
| | ==SUBJECT:== |
| | CORRECTION TO NAC INTERNATIONAL TECHNICAL SPECIFICATIONS FOR AMENDMENT NO. 7 TO MAGNASTOR STORAGE SYSTEMS FOR CERTIFICATE OF COMPLIANCE NO. 1031 (CAC NO. 001028, DOCKET NO. |
| | 72-1031, EPID: L-2018-LLA-0561) |
| | |
| | ==Dear Mr. Fowler:== |
| | |
| | By letter dated December 14, 2018 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML18352A886), the cask vendor, NAC International, Inc. notified the U.S. Nuclear Regulatory Commission (NRC) staff that Technical Specifications, Appendix A to Amendment No. 7 for the MAGNASTOR storage system for Certificate of Compliance No. |
| | 1031 included an editorial error. Specifically, Technical Specification A.5.2.e should have referred to the operating procedures for the newly added Passive MAGNASTOR Transfer Cask (PMTC). |
| | Upon further review, the NRC staff determined that in Amendment No. 7, Technical Specification A.5.2.e inadvertently omitted a necessary reference to the applicable procedures in the Technical Specifications. The NRC staff determined this omission is editorial and non-substantive. Technical Specification A.5.2.e should read: |
| | The integrity of the inner port cover welds to the closure lid at the vent port and at the drain port shall be verified in accordance with the procedures in Section 9.1.1 for the MTC or 9.4.1 for the PMTC. |
| | The NRC processed a corrective amendment to Technical Specification A.5.2.e. Enclosure 1 (ADAMS Accession No. ML19045A346) contains the page with the corrected technical specifications for the CoC No. 1031 for Amendment No. 7. |
| | A notice was published on March 20, 2019 (84 FR 10257), in the Federal Register reflecting this action. |
| | |
| | W. Fowler Please reference CAC No. 001028, Docket No. 72-1031, EPID: L-2018-LLA-0561 in future correspondence related to this corrective action. If you have any questions, please contact Bernard White of my staff at (301) 415-6657. |
| | Sincerely, |
| | /RA/ |
| | Ilka Berrios, Acting Chief Spent Fuel Licensing Branch Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards CAC No.: 001028 Docket No.: 72-1031 EPID: L-2018-LLA-0561 |
| | |
| | ==Enclosures:== |
| | |
| | Corrected Technical Specification page |
| | |
| | ML19045A347 TS Page Accession No. ML19045A346 OFFICE: DSFM DSFM OGC DSFM NAME: BWhite WWheatley JBielecki IBerrios DATE: 2/6/19 2/6/19 3/8/19 3/24/19}} |
Latest revision as of 01:53, 20 October 2019
Letter Sequence Other |
---|
|
|
MONTHYEARML19045A3462019-03-0808 March 2019 Enclosucorrected Technical Specification Page (Letter to W. Fowler Correction to NAC International Technical Specifications for Amendment No. 7 to Magnastor Storage Systems for Certificate of Compliance No. 1031) Project stage: Other ML19045A3472019-03-24024 March 2019 Letter to W. Fowler Correction to NAC International Technical Specifications for Amendment No. 7 to Magnastor Storage Systems for Certificate of Compliance No 1031 Project stage: Other 2019-03-24
[Table View] |
|
---|
Category:Letter
MONTHYEARML24008A2482024-01-0808 January 2024 NAC International, Response to Apparent Violations (a and B) in NRC Inspection Report 72-1031/2023-201; EA-2023-069 ML23283A2382023-12-0707 December 2023 NAC International, Inc. - U.S. Nuclear Regulatory Commission Inspection Report 72-1031/2023-201 ML23250A3242023-09-12012 September 2023 1. Transmittal Letter Magnastor Issuance of Amendment Nos 11 and 12 and Revision of Amendment Nos 0 Through 9 ML23166B0832023-07-0505 July 2023 Independence Spent Fuel Storage Installation - Issuance of Exemption ML23143A3912023-05-23023 May 2023 Independent Spent Fuel Storage Installation - Request for Exemption from NAC-MAGNASTOR Certificate of Compliance 72-1031 - Cask Lid Batch 3 Design Requirements ML23074A2522023-03-29029 March 2023 Application for Amendment No. 13 to the Model No. Magnastor Storage Cask Request for Additional Information ML23076A2272023-03-17017 March 2023 Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Transportable Storage Canister Identification Numbers AMZDFX165 and AMZDFX166 and Vertical Concrete Cask Identification Numbers ML23005A2572023-01-0505 January 2023 Request to Withdraw Administrative Controls for Adverse Weather Events During Operations from Magnastor Amendment 12 Supplement ML22349A4682022-12-19019 December 2022 Amendment No. 10 to Certificate of Compliance No. 1031 for the Magnastor Storage System ML22340A5902022-12-0808 December 2022 Acknowledgement Letter - Magnastor Amendment 13 ML22327A2252022-11-23023 November 2022 NAC International - Magnastor Cask System Users CoC Amendment 12 Supplement and Intent to Adopt Letters ML22321A2682022-11-17017 November 2022 Supplement to the Submission of an Amendment Request for the NAC International Magnastor Cask System, Amendment No. 13 ML22308A1942022-11-0909 November 2022 NAC International, Inc. - U.S. Nuclear Regulatory Commission Report No. 72-1031/2022-201 ML22287A0382022-10-13013 October 2022 Supplement to the Submission of an Amendment Request for the NAC International Magnastor Cask System, Amendment No. 13 ML22257A2562022-09-14014 September 2022 Registration of Dry Spent Fuel Transportable Storage Canisters Identification Numbers AMZDFX170 and AMZDFX174 and Vertical Concrete Cask Identification Numbers AMZDNE170 and AMZDNE174 ML22230D0802022-08-18018 August 2022 Independent Spent Fuel Storage Installation - Registration of Dry Spent Fuel Transportable Storage Container ML22216A1102022-08-0404 August 2022 Magnastor Cask System Users CoC Amendments 0 Thru 9 Intent to Adopt Letters ML22208A0782022-07-27027 July 2022 Registration of Use of Cask to Store Spent Fuel ML22196A0232022-07-15015 July 2022 Submittal of Supplemental Information to the Nrc'S Request for Additional Information for the NAC International Magnastor Cask System Amendment No. 11 ML22201A0662022-07-13013 July 2022 NAC International, Inc., Submittal of Data Disk for the Magnastor Cask System, Amendment No. 13 ML22194A9082022-07-13013 July 2022 NAC, Submittal of an Amendment Request for the NAC International Magnastor Cask System, Amendment No. 13 ML22111A3572022-05-16016 May 2022 Letter Issuing Exemption to Catawba ML22111A3112022-05-16016 May 2022 Letter Issuing Exemption to McGuire ML22111A2842022-05-13013 May 2022 Independence Spent Fuel Storage Installation - Issuance of Exemption ML22110A1112022-05-13013 May 2022 Letter Issuing Exemption to TMI-1 ML22125A1532022-05-0505 May 2022 Registration of Use of Casks to Store Spent Fuel ML22118B1622022-04-28028 April 2022 Request for Exemption from NAC-MAGNASTOR Certificate of Compliance 72-1031 - Cask Lid Design Requirements - Supplement RS-22-062, Supplemental Information to Exemption to the Requirements of Certificate of Compliance No. 1031 for the NAC Magnastor Storage System2022-04-26026 April 2022 Supplemental Information to Exemption to the Requirements of Certificate of Compliance No. 1031 for the NAC Magnastor Storage System ML22108A1972022-04-18018 April 2022 RAI Response to Nac'S Amendment Request for the NAC International Magnastor Cask System Amendment No. 12 ML22095A1012022-04-12012 April 2022 Application for Amendment No. 12 to the Model No. Magnastor Storage Cask - Request for Additional Information ML22101A0042022-04-0707 April 2022 Registration of Use of Casks to Store Spent Fuel ML22090A0982022-03-31031 March 2022 Independent Spent Fuel Storage Installation - Request for Exemption from NAC-MAGNASTOR Certificate of Compliance 72-1031 - Cask Lid Design Requirements ML22082A2762022-03-23023 March 2022 Independent Spent Fuel Storage Installation - Registration of Dry Spent Fuel Transportable Storage Canister Identification Numbers AMZDFX164 and AMZDFX168 and Vertical Concrete Cask Identification Numbers ML22077A7692022-03-18018 March 2022 Supplement to Nac'S Amendment Request for the NAC International Magnastor Cask System Amendment No. 12 ML22024A3742022-01-24024 January 2022 Submission of an Amendment Requestfor the NAC International Magnastor Cask System Amendment No. 12 ML22018A0592022-01-11011 January 2022 NAC International, Inc., Submittal of Supplemental Information to the Nrc'S Request for Additional Information for the NAC International Magnastor Cask System Amendment No.11 ML21277A0452021-09-24024 September 2021 Submittal of Final Safety Analysis Report (Fsar), Revision 12, for the NAC Magnastor Cask System ML21251A5302021-09-0202 September 2021 Supplemental Responses to the NRCs Request for Additional Information for the NAC International Magnastor Cask System Amendment No. 10 ML21242A0502021-08-23023 August 2021 Submission of Responses to the Nrc'S Request for Additional Information for the NAC International Magnastor Cask System Amendment No. 11 ML21174A0732021-07-12012 July 2021 Application for Amendment No. 10 to the Model No. Magnastor Storage Cask - Second Request for Additional Information ML21183A1872021-07-0202 July 2021 Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Transportable Storage Canister Identification Number AMZDFX163 and Vertical Concrete Cask Identification Number AMZDNE163 ML21102A0872021-05-0707 May 2021 NRC Review of NAC Internationals Response Letter to Inspection Report 07201015/2020201 Notice of Violation EA-20-066; and Response to Disputed Notice of Violation ML21118A0432021-04-20020 April 2021 NAC International, Inc., Supplemental Responses to the NRCs Request for Additional Information for the Cask System Amendment No. 10 ML21078A5142021-03-19019 March 2021 Independent Spent Fuel Storage Installation - Registration of Dry Spent Fuel Transportable Storage Canister Identification Number AMZDFX161 and Vertical Concrete Cask Identification Number AMZDNE161 ML21047A1992021-02-26026 February 2021 Application for Amendment No. 11 to the Model No. Magnastor Storage Cask - First Request for Additional Information ML21067A0422021-02-25025 February 2021 Submission of Responses to the Nrc'S Request for Additional Information for the NAC International Magnastor Cask System Amendment No. 10 ML21050A3262021-02-19019 February 2021 Independent Spent Fuel Storage Installation - Registration of Dry Spent Fuel Transportable Storage Canister ML21036A0372021-01-29029 January 2021 NAC International Reply to Notice of Violation (EA-20-066), January 29, 2021 (Docket Nos.: 72-1015, 72-1025, 72-1031) ML20351A4512020-12-16016 December 2020 License Amendment Request, Proposed Revision to License Conditions and Permanently Defueled Technical Specifications for Permanent Removal of Irradiated Fuel from the Spent Fuel Pool (ISFSI-Only Tech Specs) ML20307A1172020-11-10010 November 2020 Transmittal Letter - Amendment No. 9 to Certificate of Compliance No. 1031 for Magnastor Storage System 2024-01-08
[Table view] |
Text
March 24, 2019 Mr. Wren Fowler Licensing Manager NAC International 3930 East Jones Bridge Road Suite 200 Norcross, GA 30092
SUBJECT:
CORRECTION TO NAC INTERNATIONAL TECHNICAL SPECIFICATIONS FOR AMENDMENT NO. 7 TO MAGNASTOR STORAGE SYSTEMS FOR CERTIFICATE OF COMPLIANCE NO. 1031 (CAC NO. 001028, DOCKET NO.
72-1031, EPID: L-2018-LLA-0561)
Dear Mr. Fowler:
By letter dated December 14, 2018 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML18352A886), the cask vendor, NAC International, Inc. notified the U.S. Nuclear Regulatory Commission (NRC) staff that Technical Specifications, Appendix A to Amendment No. 7 for the MAGNASTOR storage system for Certificate of Compliance No.
1031 included an editorial error. Specifically, Technical Specification A.5.2.e should have referred to the operating procedures for the newly added Passive MAGNASTOR Transfer Cask (PMTC).
Upon further review, the NRC staff determined that in Amendment No. 7, Technical Specification A.5.2.e inadvertently omitted a necessary reference to the applicable procedures in the Technical Specifications. The NRC staff determined this omission is editorial and non-substantive. Technical Specification A.5.2.e should read:
The integrity of the inner port cover welds to the closure lid at the vent port and at the drain port shall be verified in accordance with the procedures in Section 9.1.1 for the MTC or 9.4.1 for the PMTC.
The NRC processed a corrective amendment to Technical Specification A.5.2.e. Enclosure 1 (ADAMS Accession No. ML19045A346) contains the page with the corrected technical specifications for the CoC No. 1031 for Amendment No. 7.
A notice was published on March 20, 2019 (84 FR 10257), in the Federal Register reflecting this action.
W. Fowler Please reference CAC No. 001028, Docket No. 72-1031, EPID: L-2018-LLA-0561 in future correspondence related to this corrective action. If you have any questions, please contact Bernard White of my staff at (301) 415-6657.
Sincerely,
/RA/
Ilka Berrios, Acting Chief Spent Fuel Licensing Branch Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards CAC No.: 001028 Docket No.: 72-1031 EPID: L-2018-LLA-0561
Enclosures:
Corrected Technical Specification page
ML19045A347 TS Page Accession No. ML19045A346 OFFICE: DSFM DSFM OGC DSFM NAME: BWhite WWheatley JBielecki IBerrios DATE: 2/6/19 2/6/19 3/8/19 3/24/19