{{#Wiki_filter:}} | {{#Wiki_filter:ATTACHMENT 7 PNP 2018-025 Traveler TSTF-425 Versus Palisades Nuclear Plant (PNP) | ||
Renewed Facility Operating License (RFOL) | |||
Surveillance Requirement (SR) | |||
Applicability Cross Reference Table 11 Pages Follow | |||
ATTACHMENT 7 PNP 2018-025 Traveler TSTF-425 Versus PNP RFOL SR Applicability Cross Reference Table The below TSTF-425 applicability cross reference table is provided as a reviewers aid for the application of TSTF-425 to ENO's PNP RFOL TS. The table contains the following information. | |||
: 1. Column one, labeled TSTF-425 SR, contains the TSTF-425 NUREG-1432 STS surveillance requirement reference in the same sequence as listed in TSTF-425. | |||
A blank cell in this column denotes that a PNP SR included in the LAR does not have a corresponding TSTF-425 SR and as such is identified as a variance to TSTF-425. | |||
: 2. Column two, labeled TSTF-425 TS Section Title, contains the TSTF-425 NUREG STS section title as written in TSTF-425. | |||
: 3. Column three, labeled PNP SR, contains the PNP surveillance requirement number as listed in PNP's RFOL TS through license amendment number 266. A blank cell in this column denotes that a TSTF-425 SR does not have a corresponding PNP SR and therefore relocation of its frequency to the PNP surveillance frequency control program is not included in the LAR. | |||
: 4. Column four, labeled PNP SR Frequency, contains the current PNP TS SR frequency that is proposed to be relocated to a surveillance frequency control program. | |||
: 5. Column five, labeled Var., identifies if the listed SR is a variation to TSTF-425. | |||
: 6. Column six, labeled Var. Just. Ref. (Att1 Tbl.), lists the table number in Attachment 1 to this LAR that addresses the variances with respect to TSTF-425. | |||
For reference when using the below table the following is provided. | |||
Table 1 PNP SITE SPECFIC TS SURVIELLANCE REQUIREMENTS Table 2 PNP TS SECTION NUMBER DIFFERENCES Table 3 TSTF-425 (CEOG STS) CHANGES NOT IN PNP TS Table 4 TSTF-425 (CEOG STS) CHANGES NOT APPLICABLE DUE TO PNP DESIGN Abbreviations used that are specific to the table below are: | |||
* N/A Not Applicable | |||
* Y Yes | |||
* N No | |||
* h hours | |||
* EFPD effective full power days | |||
* m months | |||
* d days | |||
* min minutes Page 1 of 11 | |||
ATTACHMENT 7 PNP 2018-025 Traveler TSTF-425 Versus PNP RFOL SR Applicability Cross Reference Table Var. Just. | |||
TSTF-425 TSTF-425 TS PNP PNPSR Var. Ref. | |||
SR Section Title SR Frequency (Att1 Tbl.) | |||
1.1 Definitions 1.1 N/A Y 3 Shutdown Margin (SDM) 3.1.1.1 3.1.1.1 24 h N N/A (Analog) 3.1.2.1 Reactivity Balance (Analog) 3.1.2.1 31 EFPD N N/A 3.1.4.1 CEA Alignment (Analog) 3.1.4.1 12 h N 1 3.1.4.2 3 3.1.4.2 12 h Y 1 3.1.4.3 3.1.4.4 18 m Y 1 3.1.4.4 3.1.4.3 92 d Y 2 3.1.4.5 3.1.4.5 18 m Y 1 Shutdown CEA Insertion Limits 3.1.5.1 3.1.5.1 12 h N N/A (Analog) | |||
Regulating CEA Insertion Limits 3.1.6.1 3.1.6.1 12 h Y 1 | |||
.(Analog) 3.1.6.2 3 3.1.6.3 3.1.6.2 31 d Y 2 3.1.6.3 31 d Y 1 3.1.7.1 STE-SDM (Analog) 3 3.1.8.1 STE- MODES 1 and 2 (Analog) 3.1.7.1 1h Y 1 3.1.7.2 1h Y 1 3.1.7.3 24 h Y 1 3.1.1.1 (SDM) (Digital) 4 3.1.2.1 Reactivity Balance (Digital) 4 3.1.4.1 CEA Alignment (Digital) 4 3.1.4.2 4 3.1.4.3 4 3.1.4.4 4 Shutdown CEA Insertion Limits 3.1.5.1 4 (Digital) | |||
Regulating CEA Insertion Limits 3.1.6.1 4 (Digital) 3.1.6.2 4 3.1.6.3 4 Part Length CEA Insertion Limits 3.1.7.1 4 (DiQital) 3.1.8.1 STE-SDM (Digital) 4 3.1.9.1 STE- MODES 1 and 2 (Digital) 4 3.2.1.1 LHR (Analog) 3 3.2.1.1 12 h Y 1 3.2.1.2 3.2.1.2 31 EFPD Y 1 3.2.1.3 3 3.2.1.4 1h Y 1 3.2.1.5 1h Y 1 3.2.1.6 24 h Y 1 Page 2 of 11 | |||
ATTACHMENT 7 PNP 2018-025 Traveler TSTF-425 Versus PNP RFOL SR Applicability Cross Reference Table Var. Just. | |||
TSTF-425 TSTF-425 TS PNP PNPSR Var. Ref. | |||
SR Section Title SR Frequency (Att1 Tbl.) | |||
3.2.2.1 F' xv (Analog) 3 3.2.3.1 Fr' (Analog) 3.2.2.1 31 EFPD Y 1 3.2.4.1 Fq (Analog) 3.2.3.1 12 h Y 1 3.2.5.1 ASI (Analog) 3.2.4.1 12 h N 2 3.2.1.1 LHR (Digital) 4 3.2.1.2 4 3.2.2.1 Fxv (Digital) 4 3.2.3.1 Fa (Digital) 4 3.2.3.2 4 3.2.3.3 4 3.2.4.1 DNBR (Digital) 4 3.2.4.2 4 3.2.5.1 ASI (Digital) 4 RPS Instrumentation-3.3.1.1 3.3.1.1 12 h Y 1 Operating (Analog) 3.3.1.2 3.3.1.3 24 h N 2 3.3.1.2 12 h Y 1 3.3.1.3 3.3.1.4 31 d N 2 3.3.1.4 3.3.1.5 92 d Y 1 3.3.1.5 3.3.1.6 92 d Y 1 3.3.1.8 3.3.1.8 18 m Y 1 3.3.1.9 3 RPS Instrumentation-3.3.2.1 3 Shutdown (Analog) 3.3.2.2 3 3.3.2.3 3 3.3.2.4 3 RPS Logic and Trip Initiation 3.3.3.1 3 (Analog) 3.3.3.2 3.3.2.1 92 d Y 1 3.3.3.4 3 ESFAS Instrumentation 3.3.4.1 3.3.3.1 12 h Y 1 (Analog) 3.3.4.2 3.3.3.2 92 d Y 1 3.3.4.4 3.3.3.3 18 m Y 1 3.3.4.5 3 3.3.4.1 ESFAS Logic and Manual Trip 3.3.5.1 3.3.4.2 92 d Y 1 (Analog) 3.3.4.3 3.3.4.1 3.3.5.2 3.3.4.2 92 d Y 1 3.3.4.3 3.3.6.1 DG - LOVS (AnaloQ) 3 3.3.6.2 3.3.5.1 18 m Y 1 Page 3 of 11 | |||
ATTACHMENT 7 PNP 2018-025 Traveler TSTF-425 Versus PNP RFOL SR Applicability Cross Reference Table Var. Just. | |||
TSTF-425 TSTF-425 TS PNP PNPSR Var. Ref. | |||
SR Section Title SR Frequency (Att1 Tbl.) | |||
3.3.6.3 3.3.5.2 18 m Y 1 3.3.7.1 CPIS (Analog) 4 3.3.7.2 4 3.3.7.3 4 3.3.7.4 4 3.3.7.5 4 3.3.7.6 4 3.3.8.1 CRIS (Analog) 3.3.6.1 12 h Y 1 3.3.8.2 3 3.3.8.3 3.3.6.2 31 d Y 1 3.3.8.4 3.3.6.4 18 m Y 1 3.3.8.5 3.3.6.3 18 m Y 1 3.3.8.6 3 3.3.9.1 CVCS Isolation Signal (Analog) 4 3.3.9.2 4 3.3.9.3 4 3.3.10.1 SBFAS (Analog) 4 3.3.10.1 12 h Y 1 3.3.10.2 31 d Y 1 3.3.10.3 18 m Y 1 3.3.10.2 4 3.3.11.1 PAM Instrumentation (Analog) 3.3.7.1 31 d N 2 3.3.11.2 3.3.7.2 18 m N 2 Remote Shutdown System 3.3.12.1 3 (Analog) 3.3.12.2 3.3.8.2 18 m N 2 3.3.12.3 3.3.8.3 18 m N 2 3.3.12.4 4 | |||
[Logarithmic] Power Monitoring 3.3.13.1 3.3.9.1 12 h N 2 Channels (Analog) 3.3.13.2 3 3.3.13.3 3.3.9.2 18 m N 2 RPS Instrumentation - | |||
3.3.1.1 4 Operating (Digital) 3.3.1.2 4 3.3.1.3 4 3.3.1.4 4 3.3.1.5 4 3.3.1.6 4 3.3.1.7 4 3.3.1.8 4 3.3.1.9 4 3.3.1.10 4 3.3.1.11 4 Page 4 of 11 | |||
ATTACHMENT 7 PNP 2018-025 Traveler TSTF-425 Versus PNP RFOL SR Applicability Cross Reference Table Var. Just. | |||
TSTF-425 TSTF-425 TS PNP PNPSR Var. Ref. | |||
SR Section Title SR Frequency (Att1 Tbl.) | |||
3.3.1.14 4 RPS Instrumentation-3.3.2.1 4 Shutdown (Digital) 3.3.2.2 4 3.3.2.4 4 3.3.2.5 4 3.3.3.1 CEACs (Digital) 4 3.3.3.2 4 3.3.3.3 4 3.3.3.4 4 3.3.3.5 4 3.3.3.6 4 RPS Logic and Trip Initiation 3.3.4.1 4 (Digital) 3.3.4.2 4 3.3.4.3 4 3.3.5.1 ESFAS Instrumentation (Digital) 4 3.3.5.2 4 3.3.5.3 4 3.3.5.4 4 ESFAS Logic and Manual Trip 3.3.6.1 4 (Digital) 3.3.6.2 4 3.3.6.3 4 3.3.7.1 DG - LOVS (Digital) 4 3.3.7.2 4 3.3.7.3 4 3.3.8.1 CPIS (Digital) 4 3.3.8.2 4 3.3.8.3 4 3.3.8.4 4 3.3.8.5 4 3.3.8.6 4 3.3.8.7 4 3.3.8.8 4 3.3.9.1 CRIS (Digital) 4 3.3.9.2 4 3.3.9.3 4 3.3.9.4 4 3.3.9.5 4 3.3.9.6 4 3.3.10.1 FHIS (Digital) 4 3.3.10.2 4 3.3.10.3 4 Page 5 of 11 | |||
ATTACHMENT 7 PNP 2018-025 Traveler TSTF-425 Versus PNP RFOL SR Applicability Cross Reference Table Var. Just. | |||
TSTF-425 TSTF-425 TS PNP PNPSR Var. Ref. | |||
SR Section Title SR Frequency (Att1 Tbl.) | |||
3.3.10.4 4 3.3.10.5 4 3.3.10.6 4 3.3.11.1 PAM Instrumentation (Digital) 4 3.3.11.2 4 Remote Shutdown System 3.3.12.1 4 (Digital) 3.3.12.2 4 3.3.12.3 4 3.3.12.4 4 | |||
[Logarithmic] Power Monitoring 3.3.13.1 4 Channels (Digital) 3.3.13.2 4 3.3.13.3 4 RCS Pressure, Temperature, 3.4.1.1 3.4.1.1 12 h Y 1 and Flow [DNB] Limits 3.4.1.2 3.4.1.2 12 h Y 1 3.4.1.3 3 3.4.1.4 3.4.1.3 18 m Y 1 RCS Minimum Temperature for 3.4.2.1 Criticality 3.4.2.1 12 h N N/A 3.4.3.1 RCS PIT Limits 3.4.3.1 30 min Y 1 3.4.4.1 RCS Loops - MODES 1 and 2 3.4.4.1 12 h N N/A 3.4.5.1 RCS Loops - MODE 3 3.4.5.1 12 h Y 1 3.4.5.2 3.4.5.2 12 h N N/A 3.4.5.3 3.4.5.3 7d Y 1 3.4.6.1 RCS Loops - MODE 4 3.4.6.1 12 h Y 1 3.4.6.2 3.4.6.2 12 h N N/A 3.4.6.3 3.4.6.3 7d Y 1 RCS Loops - MODE 5, Loops 3.4.7.1 3.4.7.1 12 h Y 1 Filled 3.4.7.2 3.4.7.2 12 h N N/A 3.4.7.3 3.4.7.3 7d Y 1 RCS Loops - MODE 5, Loops 3.4.8.1 3.4.8.1 12 h Y 1 Not Filled 3.4.8.2 12 h Y 1 3.4.8.3 12 h Y 1 3.4.8.2 3.4.8.4 7d Y 1 3.4.9.1 Pressurizer 3.4.9.1 12 h N N/A 3.4.9.2 3.4.9.2 18 m Y 1 3.4.9.3 3.4.9.3 18 m Y 1 3.4.11.1 Pressurizer POVRs 3 3.4.11.2 3.4.11.2 18 m Y 1 3.4.11.3 3 Page 6 of 11 | |||
ATTACHMENT 7 PNP 2018-025 Traveler TSTF-425 Versus PNP RFOL SR Applicability Cross Reference Table Var. Just. | |||
TSTF-425 TSTF-425 TS PNP PNPSR Var. Ref. | |||
SR Section Title SR Frequency (Att1 Tbl.) | |||
3.4.11.4 3 3.4.12.1 LTOP System 3.4.12.1 12 h Y 1 3.4.12.2 4 3.4.12.3 3 12 hand y 3.4.12.4 3.4.12.2 1 31 d 3.4.12.5 3.4.12.3 72 h N 2 3.4.12.6 3.4.12.4 31 d N 2 3.4.12.7 3.4.12.5 18 m N 2 3.4.13.1 RCS Operational LEAKAGE 3.4.13.1 72 h N N/A 3.4.13.2 3.4.13.2 72 h N N/A 3.4.14.1 RCS PIV Leakage 3.4.14.1 18 m Y 1 3.4.14.2 3.4.14.2 18 m Y 1 3.4.14.3 4 RCS Leakage Detection 3.4.15.1 12 h Y 1 Instrumentation 3.4.15.1 3.4.15.2 12 h Y 1 3.4.15.2 3 3.4.15.3 12 h Y 1 3.4.15.4 18 m Y 1 3.4.15.3 3.4.15.5 18 m Y 1 3.4.15.4 3.4.15.6 18 m Y 1 3.4.15.5 3 3.4.15.7 18 m Y 1 3.4.16.1 RCS Specific Activity 3.4.16.1 7d N N/A 3.4.16.2 3.4.16.2 14 d N N/A 3.4.16.3 3.4.16.3 184 d N N/A 3.4.17.1 STE-RCS Loops 3 3.5.1.1 SITs 3.5.1.1 12 h N N/A 3.5.1.2 3.5.1.2 12 h N N/A 3.5.1.3 3.5.1.3 12 h Y 1 3.5.1.4 3.5.1.4 31 d N N/A 3.5.1.5 3.5.1.5 31 d Y 1 3.5.2.1 ECCS - Operating 3.5.2.1 12 h N N/A 3.5.2.2 3.5.2.2 31 d N N/A 3.5.2.3 3 3.5.2.3 31 d Y 1 3.5.2.6 3.5.2.5 18 m N 2 3.5.2.7 3.5.2.6 18 m N 2 3.5.2.8 3.5.2.7 18 m N 2 3.5.2.9 3.5.2.8 18 m N 2 3.5.2.10 3.5.2.9 18 m Y 1 3.5.4.1 RWT 3.5.4.1 24 h N N/A 3.5.4.2 3.5.4.2 7d Y 1 Page 7 of 11 | |||
ATTACHMENT 7 PNP 2018-025 Traveler TSTF-425 Versus PNP RFOL SR Applicability Cross Reference Table Var. Just. | |||
TSTF-425 TSTF-425 TS PNP PNPSR Var. Ref. | |||
SR Section Title SR Frequency (Att1 Tbl.) | |||
3.5.4.3 7d Y 1 3.5.4.3 3.5.4.4 31 d Y 1 3.5.5.1 TSP 3.5.5.1 18 m Y 1 3.5.5.2 3.5.5.2 18 m Y 1 Containment Air Locks 3.6.2.2 (Atmospheric and Dual) 3.6.2.2 24m N N/A Containment Isolation Valves 3.6.3.1 4 (Atmospheric and Dual) 3.6.3.2 3.6.3.1 31 d Y 1 3.6.3.3 3.6.3.2 31 d Y 1 3.6.3.5 3 3.6.3.6 3.6.3.5 184 Y 1 3.6.3.7 3.6.3.6 18 m N 2 3.6.3.8 4 Containment Pressure 3.6.4.1 3.6.4.1 12 h N N/A (Atmospheric and Dual) | |||
Containment Air Temperature 3.6.5.1 (Atmospheric and Dual) 3.6.5.1 24 h N N/A Containment Spray and Cooling 3.6.6A.1 Systems (Atmospheric and 3.6.6.1 31 d N N/A Dual) 3.6.6A.2 3.6.6.2 31 d Y 1 3.6.6A.3 3.6.6.4 18 m Y 1 3.6.6A.4 3.6.6.3 31 d N 2 3.6.6A.6 3.6.6.6 18 m N N/A 3.6.6A.7 3.6.6.7 18 m N N/A 3.6.6A.8 3.6.6.8 18 m Y 1 3.6.6A.9 3.6.6.9 3 Containment Spray and Cooling 3.6.68.1 Systems (Atmospheric and 4 Dual) 3.6.68.2 4 3.6.68.3 4 3.6.68.4 4 3.6.68.6 4 3.6.68.7 4 3.6.68.8 4 3.6.68.9 4 Spray Additive System 3.6.7.1 4 (Atmospheric and Dual) 3.6.7.2 4 3.6.7.3 4 3.6.7.5 4 3.6.7.6 4 Page 8 of 11 | |||
ATTACHMENT 7 PNP 2018-025 Traveler TSTF-425 Versus PNP RFOL SR Applicability Cross Reference Table Var. Just. | |||
TSTF-425 TSTF-425 TS PNP PNPSR Var. Ref. | |||
SR Section Title SR Frequency (Att1 Tbl.) | |||
3.6.8.1 SBEACS (Dual) 4 3.6.8.3 4 3.6.8.4 4 3.6.8.5 4 3.6.9.1 HMS (Atmospheric and Dual) 4 3.6.9.2 4 3.6.9.3 4 3.6.10.1 ICS (Atmospheric and Dual) 4 3.6.10.3 4 3.6.10.4 4 3.6.11.1 Shield Building (Dual) 4 3.6.11.2 4 3.6.11.4 4 3.7.2.2 MSIVs 3.7.2.1 18 m Y 1 MFIVs [and [MFIV] Bypass 3.7.3.2 3.7.3.1 18 m Y 1 Valves] | |||
3.7.4.1 ADVs 3.7.4.1 18 m N N/A 3.7.4.2 4 3.7.5.1 AFW System 3.7.5.1 31 d Y 1 3.7.5.3 3.7.5.3 18 m N N/A 3.7.5.4 3.7.5.4 18 m Y 1 3.7.6.1 CST 3.7.6.1 12 h Y 1 3.7.7.1 CCW System 3.7.7.1 31 d N N/A 3.7.7.2 3.7.7.2 18 m N N/A 3.7.7.3 3.7.7.3 18 m Y 1 3.7.8.1 SWS 3.7.8.1 31 d N N/A 3.7.8.2 3.7.8.2 18 m N N/A 3.7.8.3 3.7.8.3 18 m Y 1 3.7.9.1 UHS 3.7.9.1 24 h N N/A 3.7.9.2 3.7.9.2 24 h N N/A 3.7.9.3 3 3.7.10.1 ECW 4 3.7.10.2 4 3.7.11.1 CREACS 3.7.10.1 31 d N 2 3.7.11.3 3.7.10.3 18 m N 2 3.7.11.4 3 3.7.12.1 CREATCS 3.7.11.1 18 m N 2 3.7.13.1 ECCS PREACS 4 3.7.13.1 31 d Y 1 3.7.13.3 4 3.7.13.4 4 3.7.13.5 4 3.7.14.1 FBACS 4 3.7.12.2 18 m Y 1 Page 9 of 11 | |||
ATTACHMENT 7 PNP 2018-025 Traveler TSTF-425 Versus PNP RFOL SR Applicability Cross Reference Table Var. Just. | |||
TSTF-425 TSTF-425 TS PNP PNPSR Var. Ref. | |||
SR Section Title SR Frequency (Att1 Tbl.) | |||
3.7.14.3 4 3.7.14.4 4 3.7.14.5 4 3.7.15.1 PREACS 4 3.7.15.3 4 3.7.15.4 4 3.7.15.5 4 3.7.16.1 Fuel StoraQe Pool Water Level 3.7.14.1 7d Y 1 Fuel Storage Pool Boron 3.7.17.1 3.7.15.1 7d N 2 Concentration 3.7.19.1 Secondary Specific Activity 3.7.17.1 31 d N 2 3.8.1.1 AC Sources - Operating 3.8.1.1 7d Y 1 3.8.1.2 3.8.1.2 31 d Y 1 3.8.1.3 3.8.1.3 31 d Y 1 3.8.1.4 3.8.1.4 31 d N N/A 3.8.1.5 3 3.8.1.6 3.8.3.6 92 d N 2 3.8.1.7 3 3.8.1.8 3 3.8.1.9 3.8.1.5 18 m N 2 3.8.1.10 3.8.1.6 18 m Y 1 3.8.1.11 3.8.1.7 18 m N 2 3.8.1.12 3 3.8.1.13 3 3.8.1.14 3.8.1.8 18 m Y 1 3.8.1.15 3 3.8.1.16 3.8.1.9 18 m Y 1 3.8.1.17 3 3.8.1.18 3.8.1.10 18 m Y 1 3.8.1.19 3.8.1.11 18 m N 2 3.8.1.20 3 Diesel Fuel Oil, Lube Oil, and 3.8.3.1 3.8.3.1 24 h Y 1 Starting Air 3.8.3.2 3.8.3.2 31 d Y 1 3.8.3.4 3.8.3.4 31 d N N/A 3.8.3.5 3.8.3.5 92 d Y 1 3.8.4.1 DC Sources - Operating 3.8.4.1 7d Y 1 3.8.4.2 92 d Y 1 3.8.4.3 12 m Y 1 3.8.4.4 12 m Y 1 3.8.4.5 12 m Y 1 3.8.4.2 3.8.4.6 18 m Y 1 3.8.4.3 3.8.4.7 18 m NA 2 3.8.6.1 Battery Parameters 3 Page 10 of 11 | |||
ATTACHMENT 7 PNP 2018-025 Traveler TSTF-425 Versus PNP RFOL SR Applicability Cross Reference Table Var. Just. | |||
TSTF-425 TSTF-425 TS PNP PNPSR Var. Ref. | |||
SR Section Title SR Frequency (Atn Tbl.) | |||
3.8.6.2 3.8.6.1 31 d Y 1 3.8.6.3 3.8.6.3 92 d Y 1 3.8.6.4 3.8.6.2 31 d Y 1 3.8.6.5 3.8.6.3 92 d Y 1 3.8.6.6 3.8.4.8 60 m N 2 3.8.7.1 Inverters - Operating 3.8.7.1 7d Y 1 3.8.8.1 Inverters - Shutdown 3.8.8.1 7d Y 1 3.8.9.1 Distribution Systems - OperatinQ 3.8.9.1 7d Y 1 3.8.10.1 Distribution Systems - Shutdown 3.8.10.1 7d Y 1 3.9.1.1 Boron Concentration 3.9.1.1 72 h Y 1 3.9.2.1 Nuclear Instrumentation 3.9.2.1 12 h N N/A 3.9.2.2 3.9.2.2 18 m N N/A 3.9.3.1 Containment Penetrations 3.9.3.1 7d Y 1 3.9.3.2 3.9.3.2 18 m Y 1 SDC and Coolant Circulation - | |||
3.9.4.1 3.9.4.1 12 h Y 1 High Water Level SDC and Coolant Circulation - | |||
3.9.5.1 3.9.5.1 12 h Y 1 Low Water Level 3.9.5.2 3.9.5.2 7d N N/A 3.9.6.1 Refueling Water Level 3.9.6.1 24 h Y 1 Battery Monitoring and 5.5.17 3 Maintenance Program Surveillance Frequency Control 5.5.18 5.5.17 N/A N 2 Program Page 11 of 11}} |
Latest revision as of 10:57, 27 October 2019
ML18270A328 | |
Person / Time | |
---|---|
Site: | Palisades |
Issue date: | 09/27/2018 |
From: | Entergy Nuclear Operations |
To: | Office of Nuclear Reactor Regulation |
Shared Package | |
ML18270A320 | List:
|
References | |
PNP 2018-025 | |
Download: ML18270A328 (12) | |
Text
ATTACHMENT 7 PNP 2018-025 Traveler TSTF-425 Versus Palisades Nuclear Plant (PNP)
Renewed Facility Operating License (RFOL)
Surveillance Requirement (SR)
Applicability Cross Reference Table 11 Pages Follow
ATTACHMENT 7 PNP 2018-025 Traveler TSTF-425 Versus PNP RFOL SR Applicability Cross Reference Table The below TSTF-425 applicability cross reference table is provided as a reviewers aid for the application of TSTF-425 to ENO's PNP RFOL TS. The table contains the following information.
- 1. Column one, labeled TSTF-425 SR, contains the TSTF-425 NUREG-1432 STS surveillance requirement reference in the same sequence as listed in TSTF-425.
A blank cell in this column denotes that a PNP SR included in the LAR does not have a corresponding TSTF-425 SR and as such is identified as a variance to TSTF-425.
- 2. Column two, labeled TSTF-425 TS Section Title, contains the TSTF-425 NUREG STS section title as written in TSTF-425.
- 3. Column three, labeled PNP SR, contains the PNP surveillance requirement number as listed in PNP's RFOL TS through license amendment number 266. A blank cell in this column denotes that a TSTF-425 SR does not have a corresponding PNP SR and therefore relocation of its frequency to the PNP surveillance frequency control program is not included in the LAR.
- 4. Column four, labeled PNP SR Frequency, contains the current PNP TS SR frequency that is proposed to be relocated to a surveillance frequency control program.
- 5. Column five, labeled Var., identifies if the listed SR is a variation to TSTF-425.
- 6. Column six, labeled Var. Just. Ref. (Att1 Tbl.), lists the table number in Attachment 1 to this LAR that addresses the variances with respect to TSTF-425.
For reference when using the below table the following is provided.
Table 1 PNP SITE SPECFIC TS SURVIELLANCE REQUIREMENTS Table 2 PNP TS SECTION NUMBER DIFFERENCES Table 3 TSTF-425 (CEOG STS) CHANGES NOT IN PNP TS Table 4 TSTF-425 (CEOG STS) CHANGES NOT APPLICABLE DUE TO PNP DESIGN Abbreviations used that are specific to the table below are:
- N/A Not Applicable
- Y Yes
- N No
- h hours
- EFPD effective full power days
- m months
- d days
- min minutes Page 1 of 11
ATTACHMENT 7 PNP 2018-025 Traveler TSTF-425 Versus PNP RFOL SR Applicability Cross Reference Table Var. Just.
TSTF-425 TSTF-425 TS PNP PNPSR Var. Ref.
SR Section Title SR Frequency (Att1 Tbl.)
1.1 Definitions 1.1 N/A Y 3 Shutdown Margin (SDM) 3.1.1.1 3.1.1.1 24 h N N/A (Analog) 3.1.2.1 Reactivity Balance (Analog) 3.1.2.1 31 EFPD N N/A 3.1.4.1 CEA Alignment (Analog) 3.1.4.1 12 h N 1 3.1.4.2 3 3.1.4.2 12 h Y 1 3.1.4.3 3.1.4.4 18 m Y 1 3.1.4.4 3.1.4.3 92 d Y 2 3.1.4.5 3.1.4.5 18 m Y 1 Shutdown CEA Insertion Limits 3.1.5.1 3.1.5.1 12 h N N/A (Analog)
Regulating CEA Insertion Limits 3.1.6.1 3.1.6.1 12 h Y 1
.(Analog) 3.1.6.2 3 3.1.6.3 3.1.6.2 31 d Y 2 3.1.6.3 31 d Y 1 3.1.7.1 STE-SDM (Analog) 3 3.1.8.1 STE- MODES 1 and 2 (Analog) 3.1.7.1 1h Y 1 3.1.7.2 1h Y 1 3.1.7.3 24 h Y 1 3.1.1.1 (SDM) (Digital) 4 3.1.2.1 Reactivity Balance (Digital) 4 3.1.4.1 CEA Alignment (Digital) 4 3.1.4.2 4 3.1.4.3 4 3.1.4.4 4 Shutdown CEA Insertion Limits 3.1.5.1 4 (Digital)
Regulating CEA Insertion Limits 3.1.6.1 4 (Digital) 3.1.6.2 4 3.1.6.3 4 Part Length CEA Insertion Limits 3.1.7.1 4 (DiQital) 3.1.8.1 STE-SDM (Digital) 4 3.1.9.1 STE- MODES 1 and 2 (Digital) 4 3.2.1.1 LHR (Analog) 3 3.2.1.1 12 h Y 1 3.2.1.2 3.2.1.2 31 EFPD Y 1 3.2.1.3 3 3.2.1.4 1h Y 1 3.2.1.5 1h Y 1 3.2.1.6 24 h Y 1 Page 2 of 11
ATTACHMENT 7 PNP 2018-025 Traveler TSTF-425 Versus PNP RFOL SR Applicability Cross Reference Table Var. Just.
TSTF-425 TSTF-425 TS PNP PNPSR Var. Ref.
SR Section Title SR Frequency (Att1 Tbl.)
3.2.2.1 F' xv (Analog) 3 3.2.3.1 Fr' (Analog) 3.2.2.1 31 EFPD Y 1 3.2.4.1 Fq (Analog) 3.2.3.1 12 h Y 1 3.2.5.1 ASI (Analog) 3.2.4.1 12 h N 2 3.2.1.1 LHR (Digital) 4 3.2.1.2 4 3.2.2.1 Fxv (Digital) 4 3.2.3.1 Fa (Digital) 4 3.2.3.2 4 3.2.3.3 4 3.2.4.1 DNBR (Digital) 4 3.2.4.2 4 3.2.5.1 ASI (Digital) 4 RPS Instrumentation-3.3.1.1 3.3.1.1 12 h Y 1 Operating (Analog) 3.3.1.2 3.3.1.3 24 h N 2 3.3.1.2 12 h Y 1 3.3.1.3 3.3.1.4 31 d N 2 3.3.1.4 3.3.1.5 92 d Y 1 3.3.1.5 3.3.1.6 92 d Y 1 3.3.1.8 3.3.1.8 18 m Y 1 3.3.1.9 3 RPS Instrumentation-3.3.2.1 3 Shutdown (Analog) 3.3.2.2 3 3.3.2.3 3 3.3.2.4 3 RPS Logic and Trip Initiation 3.3.3.1 3 (Analog) 3.3.3.2 3.3.2.1 92 d Y 1 3.3.3.4 3 ESFAS Instrumentation 3.3.4.1 3.3.3.1 12 h Y 1 (Analog) 3.3.4.2 3.3.3.2 92 d Y 1 3.3.4.4 3.3.3.3 18 m Y 1 3.3.4.5 3 3.3.4.1 ESFAS Logic and Manual Trip 3.3.5.1 3.3.4.2 92 d Y 1 (Analog) 3.3.4.3 3.3.4.1 3.3.5.2 3.3.4.2 92 d Y 1 3.3.4.3 3.3.6.1 DG - LOVS (AnaloQ) 3 3.3.6.2 3.3.5.1 18 m Y 1 Page 3 of 11
ATTACHMENT 7 PNP 2018-025 Traveler TSTF-425 Versus PNP RFOL SR Applicability Cross Reference Table Var. Just.
TSTF-425 TSTF-425 TS PNP PNPSR Var. Ref.
SR Section Title SR Frequency (Att1 Tbl.)
3.3.6.3 3.3.5.2 18 m Y 1 3.3.7.1 CPIS (Analog) 4 3.3.7.2 4 3.3.7.3 4 3.3.7.4 4 3.3.7.5 4 3.3.7.6 4 3.3.8.1 CRIS (Analog) 3.3.6.1 12 h Y 1 3.3.8.2 3 3.3.8.3 3.3.6.2 31 d Y 1 3.3.8.4 3.3.6.4 18 m Y 1 3.3.8.5 3.3.6.3 18 m Y 1 3.3.8.6 3 3.3.9.1 CVCS Isolation Signal (Analog) 4 3.3.9.2 4 3.3.9.3 4 3.3.10.1 SBFAS (Analog) 4 3.3.10.1 12 h Y 1 3.3.10.2 31 d Y 1 3.3.10.3 18 m Y 1 3.3.10.2 4 3.3.11.1 PAM Instrumentation (Analog) 3.3.7.1 31 d N 2 3.3.11.2 3.3.7.2 18 m N 2 Remote Shutdown System 3.3.12.1 3 (Analog) 3.3.12.2 3.3.8.2 18 m N 2 3.3.12.3 3.3.8.3 18 m N 2 3.3.12.4 4
[Logarithmic] Power Monitoring 3.3.13.1 3.3.9.1 12 h N 2 Channels (Analog) 3.3.13.2 3 3.3.13.3 3.3.9.2 18 m N 2 RPS Instrumentation -
3.3.1.1 4 Operating (Digital) 3.3.1.2 4 3.3.1.3 4 3.3.1.4 4 3.3.1.5 4 3.3.1.6 4 3.3.1.7 4 3.3.1.8 4 3.3.1.9 4 3.3.1.10 4 3.3.1.11 4 Page 4 of 11
ATTACHMENT 7 PNP 2018-025 Traveler TSTF-425 Versus PNP RFOL SR Applicability Cross Reference Table Var. Just.
TSTF-425 TSTF-425 TS PNP PNPSR Var. Ref.
SR Section Title SR Frequency (Att1 Tbl.)
3.3.1.14 4 RPS Instrumentation-3.3.2.1 4 Shutdown (Digital) 3.3.2.2 4 3.3.2.4 4 3.3.2.5 4 3.3.3.1 CEACs (Digital) 4 3.3.3.2 4 3.3.3.3 4 3.3.3.4 4 3.3.3.5 4 3.3.3.6 4 RPS Logic and Trip Initiation 3.3.4.1 4 (Digital) 3.3.4.2 4 3.3.4.3 4 3.3.5.1 ESFAS Instrumentation (Digital) 4 3.3.5.2 4 3.3.5.3 4 3.3.5.4 4 ESFAS Logic and Manual Trip 3.3.6.1 4 (Digital) 3.3.6.2 4 3.3.6.3 4 3.3.7.1 DG - LOVS (Digital) 4 3.3.7.2 4 3.3.7.3 4 3.3.8.1 CPIS (Digital) 4 3.3.8.2 4 3.3.8.3 4 3.3.8.4 4 3.3.8.5 4 3.3.8.6 4 3.3.8.7 4 3.3.8.8 4 3.3.9.1 CRIS (Digital) 4 3.3.9.2 4 3.3.9.3 4 3.3.9.4 4 3.3.9.5 4 3.3.9.6 4 3.3.10.1 FHIS (Digital) 4 3.3.10.2 4 3.3.10.3 4 Page 5 of 11
ATTACHMENT 7 PNP 2018-025 Traveler TSTF-425 Versus PNP RFOL SR Applicability Cross Reference Table Var. Just.
TSTF-425 TSTF-425 TS PNP PNPSR Var. Ref.
SR Section Title SR Frequency (Att1 Tbl.)
3.3.10.4 4 3.3.10.5 4 3.3.10.6 4 3.3.11.1 PAM Instrumentation (Digital) 4 3.3.11.2 4 Remote Shutdown System 3.3.12.1 4 (Digital) 3.3.12.2 4 3.3.12.3 4 3.3.12.4 4
[Logarithmic] Power Monitoring 3.3.13.1 4 Channels (Digital) 3.3.13.2 4 3.3.13.3 4 RCS Pressure, Temperature, 3.4.1.1 3.4.1.1 12 h Y 1 and Flow [DNB] Limits 3.4.1.2 3.4.1.2 12 h Y 1 3.4.1.3 3 3.4.1.4 3.4.1.3 18 m Y 1 RCS Minimum Temperature for 3.4.2.1 Criticality 3.4.2.1 12 h N N/A 3.4.3.1 RCS PIT Limits 3.4.3.1 30 min Y 1 3.4.4.1 RCS Loops - MODES 1 and 2 3.4.4.1 12 h N N/A 3.4.5.1 RCS Loops - MODE 3 3.4.5.1 12 h Y 1 3.4.5.2 3.4.5.2 12 h N N/A 3.4.5.3 3.4.5.3 7d Y 1 3.4.6.1 RCS Loops - MODE 4 3.4.6.1 12 h Y 1 3.4.6.2 3.4.6.2 12 h N N/A 3.4.6.3 3.4.6.3 7d Y 1 RCS Loops - MODE 5, Loops 3.4.7.1 3.4.7.1 12 h Y 1 Filled 3.4.7.2 3.4.7.2 12 h N N/A 3.4.7.3 3.4.7.3 7d Y 1 RCS Loops - MODE 5, Loops 3.4.8.1 3.4.8.1 12 h Y 1 Not Filled 3.4.8.2 12 h Y 1 3.4.8.3 12 h Y 1 3.4.8.2 3.4.8.4 7d Y 1 3.4.9.1 Pressurizer 3.4.9.1 12 h N N/A 3.4.9.2 3.4.9.2 18 m Y 1 3.4.9.3 3.4.9.3 18 m Y 1 3.4.11.1 Pressurizer POVRs 3 3.4.11.2 3.4.11.2 18 m Y 1 3.4.11.3 3 Page 6 of 11
ATTACHMENT 7 PNP 2018-025 Traveler TSTF-425 Versus PNP RFOL SR Applicability Cross Reference Table Var. Just.
TSTF-425 TSTF-425 TS PNP PNPSR Var. Ref.
SR Section Title SR Frequency (Att1 Tbl.)
3.4.11.4 3 3.4.12.1 LTOP System 3.4.12.1 12 h Y 1 3.4.12.2 4 3.4.12.3 3 12 hand y 3.4.12.4 3.4.12.2 1 31 d 3.4.12.5 3.4.12.3 72 h N 2 3.4.12.6 3.4.12.4 31 d N 2 3.4.12.7 3.4.12.5 18 m N 2 3.4.13.1 RCS Operational LEAKAGE 3.4.13.1 72 h N N/A 3.4.13.2 3.4.13.2 72 h N N/A 3.4.14.1 RCS PIV Leakage 3.4.14.1 18 m Y 1 3.4.14.2 3.4.14.2 18 m Y 1 3.4.14.3 4 RCS Leakage Detection 3.4.15.1 12 h Y 1 Instrumentation 3.4.15.1 3.4.15.2 12 h Y 1 3.4.15.2 3 3.4.15.3 12 h Y 1 3.4.15.4 18 m Y 1 3.4.15.3 3.4.15.5 18 m Y 1 3.4.15.4 3.4.15.6 18 m Y 1 3.4.15.5 3 3.4.15.7 18 m Y 1 3.4.16.1 RCS Specific Activity 3.4.16.1 7d N N/A 3.4.16.2 3.4.16.2 14 d N N/A 3.4.16.3 3.4.16.3 184 d N N/A 3.4.17.1 STE-RCS Loops 3 3.5.1.1 SITs 3.5.1.1 12 h N N/A 3.5.1.2 3.5.1.2 12 h N N/A 3.5.1.3 3.5.1.3 12 h Y 1 3.5.1.4 3.5.1.4 31 d N N/A 3.5.1.5 3.5.1.5 31 d Y 1 3.5.2.1 ECCS - Operating 3.5.2.1 12 h N N/A 3.5.2.2 3.5.2.2 31 d N N/A 3.5.2.3 3 3.5.2.3 31 d Y 1 3.5.2.6 3.5.2.5 18 m N 2 3.5.2.7 3.5.2.6 18 m N 2 3.5.2.8 3.5.2.7 18 m N 2 3.5.2.9 3.5.2.8 18 m N 2 3.5.2.10 3.5.2.9 18 m Y 1 3.5.4.1 RWT 3.5.4.1 24 h N N/A 3.5.4.2 3.5.4.2 7d Y 1 Page 7 of 11
ATTACHMENT 7 PNP 2018-025 Traveler TSTF-425 Versus PNP RFOL SR Applicability Cross Reference Table Var. Just.
TSTF-425 TSTF-425 TS PNP PNPSR Var. Ref.
SR Section Title SR Frequency (Att1 Tbl.)
3.5.4.3 7d Y 1 3.5.4.3 3.5.4.4 31 d Y 1 3.5.5.1 TSP 3.5.5.1 18 m Y 1 3.5.5.2 3.5.5.2 18 m Y 1 Containment Air Locks 3.6.2.2 (Atmospheric and Dual) 3.6.2.2 24m N N/A Containment Isolation Valves 3.6.3.1 4 (Atmospheric and Dual) 3.6.3.2 3.6.3.1 31 d Y 1 3.6.3.3 3.6.3.2 31 d Y 1 3.6.3.5 3 3.6.3.6 3.6.3.5 184 Y 1 3.6.3.7 3.6.3.6 18 m N 2 3.6.3.8 4 Containment Pressure 3.6.4.1 3.6.4.1 12 h N N/A (Atmospheric and Dual)
Containment Air Temperature 3.6.5.1 (Atmospheric and Dual) 3.6.5.1 24 h N N/A Containment Spray and Cooling 3.6.6A.1 Systems (Atmospheric and 3.6.6.1 31 d N N/A Dual) 3.6.6A.2 3.6.6.2 31 d Y 1 3.6.6A.3 3.6.6.4 18 m Y 1 3.6.6A.4 3.6.6.3 31 d N 2 3.6.6A.6 3.6.6.6 18 m N N/A 3.6.6A.7 3.6.6.7 18 m N N/A 3.6.6A.8 3.6.6.8 18 m Y 1 3.6.6A.9 3.6.6.9 3 Containment Spray and Cooling 3.6.68.1 Systems (Atmospheric and 4 Dual) 3.6.68.2 4 3.6.68.3 4 3.6.68.4 4 3.6.68.6 4 3.6.68.7 4 3.6.68.8 4 3.6.68.9 4 Spray Additive System 3.6.7.1 4 (Atmospheric and Dual) 3.6.7.2 4 3.6.7.3 4 3.6.7.5 4 3.6.7.6 4 Page 8 of 11
ATTACHMENT 7 PNP 2018-025 Traveler TSTF-425 Versus PNP RFOL SR Applicability Cross Reference Table Var. Just.
TSTF-425 TSTF-425 TS PNP PNPSR Var. Ref.
SR Section Title SR Frequency (Att1 Tbl.)
3.6.8.1 SBEACS (Dual) 4 3.6.8.3 4 3.6.8.4 4 3.6.8.5 4 3.6.9.1 HMS (Atmospheric and Dual) 4 3.6.9.2 4 3.6.9.3 4 3.6.10.1 ICS (Atmospheric and Dual) 4 3.6.10.3 4 3.6.10.4 4 3.6.11.1 Shield Building (Dual) 4 3.6.11.2 4 3.6.11.4 4 3.7.2.2 MSIVs 3.7.2.1 18 m Y 1 MFIVs [and [MFIV] Bypass 3.7.3.2 3.7.3.1 18 m Y 1 Valves]
3.7.4.1 ADVs 3.7.4.1 18 m N N/A 3.7.4.2 4 3.7.5.1 AFW System 3.7.5.1 31 d Y 1 3.7.5.3 3.7.5.3 18 m N N/A 3.7.5.4 3.7.5.4 18 m Y 1 3.7.6.1 CST 3.7.6.1 12 h Y 1 3.7.7.1 CCW System 3.7.7.1 31 d N N/A 3.7.7.2 3.7.7.2 18 m N N/A 3.7.7.3 3.7.7.3 18 m Y 1 3.7.8.1 SWS 3.7.8.1 31 d N N/A 3.7.8.2 3.7.8.2 18 m N N/A 3.7.8.3 3.7.8.3 18 m Y 1 3.7.9.1 UHS 3.7.9.1 24 h N N/A 3.7.9.2 3.7.9.2 24 h N N/A 3.7.9.3 3 3.7.10.1 ECW 4 3.7.10.2 4 3.7.11.1 CREACS 3.7.10.1 31 d N 2 3.7.11.3 3.7.10.3 18 m N 2 3.7.11.4 3 3.7.12.1 CREATCS 3.7.11.1 18 m N 2 3.7.13.1 ECCS PREACS 4 3.7.13.1 31 d Y 1 3.7.13.3 4 3.7.13.4 4 3.7.13.5 4 3.7.14.1 FBACS 4 3.7.12.2 18 m Y 1 Page 9 of 11
ATTACHMENT 7 PNP 2018-025 Traveler TSTF-425 Versus PNP RFOL SR Applicability Cross Reference Table Var. Just.
TSTF-425 TSTF-425 TS PNP PNPSR Var. Ref.
SR Section Title SR Frequency (Att1 Tbl.)
3.7.14.3 4 3.7.14.4 4 3.7.14.5 4 3.7.15.1 PREACS 4 3.7.15.3 4 3.7.15.4 4 3.7.15.5 4 3.7.16.1 Fuel StoraQe Pool Water Level 3.7.14.1 7d Y 1 Fuel Storage Pool Boron 3.7.17.1 3.7.15.1 7d N 2 Concentration 3.7.19.1 Secondary Specific Activity 3.7.17.1 31 d N 2 3.8.1.1 AC Sources - Operating 3.8.1.1 7d Y 1 3.8.1.2 3.8.1.2 31 d Y 1 3.8.1.3 3.8.1.3 31 d Y 1 3.8.1.4 3.8.1.4 31 d N N/A 3.8.1.5 3 3.8.1.6 3.8.3.6 92 d N 2 3.8.1.7 3 3.8.1.8 3 3.8.1.9 3.8.1.5 18 m N 2 3.8.1.10 3.8.1.6 18 m Y 1 3.8.1.11 3.8.1.7 18 m N 2 3.8.1.12 3 3.8.1.13 3 3.8.1.14 3.8.1.8 18 m Y 1 3.8.1.15 3 3.8.1.16 3.8.1.9 18 m Y 1 3.8.1.17 3 3.8.1.18 3.8.1.10 18 m Y 1 3.8.1.19 3.8.1.11 18 m N 2 3.8.1.20 3 Diesel Fuel Oil, Lube Oil, and 3.8.3.1 3.8.3.1 24 h Y 1 Starting Air 3.8.3.2 3.8.3.2 31 d Y 1 3.8.3.4 3.8.3.4 31 d N N/A 3.8.3.5 3.8.3.5 92 d Y 1 3.8.4.1 DC Sources - Operating 3.8.4.1 7d Y 1 3.8.4.2 92 d Y 1 3.8.4.3 12 m Y 1 3.8.4.4 12 m Y 1 3.8.4.5 12 m Y 1 3.8.4.2 3.8.4.6 18 m Y 1 3.8.4.3 3.8.4.7 18 m NA 2 3.8.6.1 Battery Parameters 3 Page 10 of 11
ATTACHMENT 7 PNP 2018-025 Traveler TSTF-425 Versus PNP RFOL SR Applicability Cross Reference Table Var. Just.
TSTF-425 TSTF-425 TS PNP PNPSR Var. Ref.
SR Section Title SR Frequency (Atn Tbl.)
3.8.6.2 3.8.6.1 31 d Y 1 3.8.6.3 3.8.6.3 92 d Y 1 3.8.6.4 3.8.6.2 31 d Y 1 3.8.6.5 3.8.6.3 92 d Y 1 3.8.6.6 3.8.4.8 60 m N 2 3.8.7.1 Inverters - Operating 3.8.7.1 7d Y 1 3.8.8.1 Inverters - Shutdown 3.8.8.1 7d Y 1 3.8.9.1 Distribution Systems - OperatinQ 3.8.9.1 7d Y 1 3.8.10.1 Distribution Systems - Shutdown 3.8.10.1 7d Y 1 3.9.1.1 Boron Concentration 3.9.1.1 72 h Y 1 3.9.2.1 Nuclear Instrumentation 3.9.2.1 12 h N N/A 3.9.2.2 3.9.2.2 18 m N N/A 3.9.3.1 Containment Penetrations 3.9.3.1 7d Y 1 3.9.3.2 3.9.3.2 18 m Y 1 SDC and Coolant Circulation -
3.9.4.1 3.9.4.1 12 h Y 1 High Water Level SDC and Coolant Circulation -
3.9.5.1 3.9.5.1 12 h Y 1 Low Water Level 3.9.5.2 3.9.5.2 7d N N/A 3.9.6.1 Refueling Water Level 3.9.6.1 24 h Y 1 Battery Monitoring and 5.5.17 3 Maintenance Program Surveillance Frequency Control 5.5.18 5.5.17 N/A N 2 Program Page 11 of 11