{{#Wiki_filter:UNITED STATES NUCLEAR REGULATORY COMMISSION REGION I 2100 RENAISSANCE BLVD. KING OF PRUSSIA, PA  19406-2713   
{{#Wiki_filter:UNITED STATES NUCLEAR REGULATORY COMMISSION REGION I 2100 RENAISSANCE BLVD. KING OF PRUSSIA, PA  19406-2713  
  November 3, 2016  EA-16-244  
   
  November 3, 2016  
   EA-16-244  
 
   
   
Mr. Peter Sena, III  
Mr. Peter Sena, III  
President and Chief Nuclear Officer PSEG Nuclear LLC - N09 P.O. Box 236  
President and Chief Nuclear Officer PSEG Nuclear LLC - N09 P.O. Box 236  
Hancocks Bridge, NJ  08038  
Hancocks Bridge, NJ  08038  
SUBJECT: U.S. NUCLEAR REGULATORY COMMISSION RESPONSE TO DISPUTED NOTICE OF NON-CITED VIOLATION 05000311/2016002-02
   
   
SUBJECT: U.S. NUCLEAR REGULATORY COMMISSION RESPONSE TO DISPUTED NOTICE OF NON-CITED VIOLATION 05000311/2016002-02 
Dear Mr. Sena:  
Dear Mr. Sena:  
   
   
I am writing to acknowledge receipt of PSEG's letter dated October 24, 2016, in response to the  
I am writing to acknowledge receipt of PSEG's letter dated October 24, 2016, in response to the  
U.S. Nuclear Regulatory Commission (NRC) Inspection Report 05000272/2016002 and 05000311/2016002 issued on September 22, 2016.   
U.S. Nuclear Regulatory Commission (NRC) Inspection Report 05000272/2016002 and 05000311/2016002 issued on September 22, 2016.  
   
The letter requests withdrawal of the 10 CFR Part 50, Appendix B, Criterion V, "Instructions,  
The letter requests withdrawal of the 10 CFR Part 50, Appendix B, Criterion V, "Instructions,  
Procedures, and Drawings," Green non-cited violation (NCV 0500311/2016002-02) concerning the failure to follow the operability process as prescribed in OP-AA-108-115, "Operability Determinations & Functionality Assessments."  The letter stated that PSEG was in full compliance with procedure OP-AA-108-115 when evaluating the baffle former bolt condition  
Procedures, and Drawings," Green non-cited violation (NCV 0500311/2016002-02) concerning the failure to follow the operability process as prescribed in OP-AA-108-115, "Operability  
Determinations & Functionality Assessments."  The letter stated that PSEG was in full compliance with procedure OP-AA-108-115 when evaluating the baffle former bolt condition  
discovered at Unit 1 as it applied to Unit 2.  The NRC will review PSEG's response and provide you a letter documenting the basis for any decision within 90 days.  
discovered at Unit 1 as it applied to Unit 2.  The NRC will review PSEG's response and provide you a letter documenting the basis for any decision within 90 days.  
   
   
In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390 of the NRC's "Rules of Practice," a copy of this letter, its enclosure, and your response (if any) will be available electronically for public inspection in the NRC's Public Document Room or from the Publicly Available Records component of the NRC's Agencywide Documents Access and  
In accordance with Title 10 of the Code of Federal Regulations  
Management System (ADAMS).  ADAMS is accessible from the NRC website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).  Your letter has also been added to ADAMS for the information of the public, and may be found under ADAMS Accession Number ML16298A161.  
(10 CFR) 2.390 of the NRC's "Rules of Practice," a copy of this letter, its enclosure, and your response (if any) will be  
available electronically for public inspection in the NRC's Public Document Room or from the Publicly Available Records component of the NRC's Agencywide Documents Access and  
Management System (ADAMS).  ADAMS is accessible from the NRC website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).  Your letter has also been added to ADAMS for the information of the public, and may be found under  
ADAMS Accession Number ML16298A161.  
 
    
    
P. Sena -2-   
P. Sena -2-  
Should you have any questions concerning this letter, please contact me at (610) 337-5150.  Sincerely,              /RA/  Raymond R. McKinley, Chief Plant Support Branch 1  
   
Division of Reactor Safety  
Should you have any questions concerning this letter, please contact me at (610) 337-5150.  
Docket No. 50-311 License No. DPR-75   
  Sincerely,  
               /RA/  Raymond R. McKinley, Chief  
Plant Support Branch 1  
 
Division of Reactor Safety
Docket No. 50-311 License No. DPR-75  
   
cc:  Distribution via ListServ  
cc:  Distribution via ListServ  


   ML16308A328   SUNSI Review  Non-Sensitive  Sensitive  Publicly Available  Non-Publicly Available  OFFICE RI/DRP RI/DRP RI/DRP  NAME RVadella/rb for  FBower/flb  RMcKinley/rrm DATE 11/3/16 11/3/1611/3/16
   ML16308A328
    SUNSI Review  
   Non-Sensitive  Sensitive  
   Publicly Available  Non-Publicly Available  
  OFFICE RI/DRP RI/DRP RI/DRP  NAME RVadella/rb for  FBower/flb  RMcKinley/rrm DATE 11/3/16 11
/3/1611/3/16
}}
}}

Revision as of 03:00, 30 June 2018

U.S. Nuclear Regulatory Commission Response to Disputed Notice of Non-Cited Violation 05000311/2016002-02
ML16308A328
Person / Time
Site: Salem PSEG icon.png
Issue date: 11/03/2016
From: Raymond McKinley
Plant Support Branch 1
To: Sena P
Public Service Enterprise Group
McKinley R R
References
EA-16-244 IR 2016002
Download: ML16308A328 (3)


See also: IR 05000311/2016002

Text

UNITED STATES NUCLEAR REGULATORY COMMISSION REGION I 2100 RENAISSANCE BLVD. KING OF PRUSSIA, PA 19406-2713

November 3, 2016

EA-16-244

Mr. Peter Sena, III

President and Chief Nuclear Officer PSEG Nuclear LLC - N09 P.O. Box 236

Hancocks Bridge, NJ 08038

SUBJECT: U.S. NUCLEAR REGULATORY COMMISSION RESPONSE TO DISPUTED NOTICE OF NON-CITED VIOLATION 05000311/2016002-02

Dear Mr. Sena:

I am writing to acknowledge receipt of PSEG's letter dated October 24, 2016, in response to the

U.S. Nuclear Regulatory Commission (NRC) Inspection Report 05000272/2016002 and 05000311/2016002 issued on September 22, 2016.

The letter requests withdrawal of the 10 CFR Part 50, Appendix B, Criterion V, "Instructions,

Procedures, and Drawings," Green non-cited violation (NCV 0500311/2016002-02) concerning the failure to follow the operability process as prescribed in OP-AA-108-115, "Operability

Determinations & Functionality Assessments." The letter stated that PSEG was in full compliance with procedure OP-AA-108-115 when evaluating the baffle former bolt condition

discovered at Unit 1 as it applied to Unit 2. The NRC will review PSEG's response and provide you a letter documenting the basis for any decision within 90 days.

In accordance with Title 10 of the Code of Federal Regulations

(10 CFR) 2.390 of the NRC's "Rules of Practice," a copy of this letter, its enclosure, and your response (if any) will be

available electronically for public inspection in the NRC's Public Document Room or from the Publicly Available Records component of the NRC's Agencywide Documents Access and

Management System (ADAMS). ADAMS is accessible from the NRC website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). Your letter has also been added to ADAMS for the information of the public, and may be found under

ADAMS Accession Number ML16298A161.

P. Sena -2-

Should you have any questions concerning this letter, please contact me at (610) 337-5150.

Sincerely,

/RA/ Raymond R. McKinley, Chief

Plant Support Branch 1

Division of Reactor Safety

Docket No. 50-311 License No. DPR-75

cc: Distribution via ListServ