ML14168A268: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
 
(4 intermediate revisions by the same user not shown)
Line 16: Line 16:


=Text=
=Text=
{{#Wiki_filter:Attachment NOC-AE-14003142 Page 1 of 155 4180 Delaware Street, Ste 402, Beaumont, Texas 77706, USA T +1 409 838 4400 F +1 409 838 9056 W www.rpsgroup.com Texas Pollutant Discharge Elimination System Major Amendment with Renewal Application for a Major Facility TPDES Permit No. WQ0001908000 Prepared For: STP Nuclear Operating.
{{#Wiki_filter:Attachment NOC-AE-14003142 Page 1 of 155 4180 Delaware Street, Ste 402, Beaumont, Texas 77706, USA T +1 409 838 4400 F +1 409 838 9056 W www.rpsgroup.com Texas Pollutant Discharge Elimination System Major Amendment with Renewal Application for a Major Facility TPDES Permit No. WQ0001908000
Company South Texas Project Electric Generating Station Bay City, Texas May 2014 (.United States I Canada I Brazil I UK I Ireland I Netherlands Australia Asia Pacific I Russia I Middle East I Africa Attachment NOC-AE-14003142 Page 2 of 155 41A0 Delaware Street, Ste 402', BeauMont, Texas 77706, USA T +1 40.9 838 4400. P 4.1 ,409 938 9056 W www,rpsgroup.com May 29, 2014 Executive Director Applications Review and Processing.Team (MC148)Texas Commission on Environmental OLrIality 12100 Park 35 Circle Austin, TX 78753 MAY 2 9 2014 vi~Erf' QUALITy DIVISION RE: ApplicatIon for the Renewal with Major Amendment of TPDES Permit No.WQ000.1908000 South: Texas Project Nuclear Operating Company (STP)
(.
Prepared For:
STP Nuclear Operating. Company South Texas Project Electric Generating Station Bay City, Texas May 2014 United States I Canada I Brazil I UK I Ireland I Netherlands Australia Asia Pacific I Russia I Middle East I Africa
 
Attachment NOC-AE-14003142 Page 2 of 155 41A0 Delaware Street, Ste 402', BeauMont, Texas 77706, USA T +1 40.9 838 4400. P 4.1 ,409 938 9056 W www,rpsgroup.com May 29, 2014 MAY 29 2014 vi~Erf' QUALITy DIVISION Executive Director Applications Review and Processing.Team (MC148)
Texas Commission on Environmental OLrIality 12100 Park 35 Circle Austin, TX 78753 RE:     ApplicatIon for the Renewal with Major Amendment of TPDES Permit No.
WQ000.1908000 South: Texas Project Nuclear Operating Company (STP)


==Dear Sir:==
==Dear Sir:==
On behalf of.STP, we are submitting the. enclosed permit renewal with major amendment application for the above referenced Texas Pollutant Discharge Elimination System (TPDES) permit. Enclosed you will find one original and three complete copies for your approval.
The application fee has.been submitted directly to the Financial Administration Division under separate cover, however, a copy of the fee submitta9l is presented in Attachment A.If you have any questions concerning this ýappl!tation, please contact me at 512-326-5859... We look forward to working with. you In prooessing this application.
Thank you for your consideration, Sincerely, Tres Koenings Senior Consultant I UnIted States IlCan~ada.l0razi I UK I.lIr~land I N~etherlands Austealla A.91a.Pbocflo I Rusela I Middle East I Africa Atnon ebir of RPS. Groulp P/C Attachment NOC-AE-14003142 Page 3 of 155 TABLE OF CONTENTS TCEQ Industrial Wastewater Permit Application TPDES Permit No. WQ0001908000 Submission Checklist Industrial Administrative Report 1.0 Industrial Administrative Report 1.1 Supplemental Permit Information Form Industrial Technical Report 1.0 Worksheet 1.0 EPA Effluent Guidelines Worksheet


===2.0 Pollutant===
On behalf of.STP, we are submitting the. enclosed permit renewal with major amendment application for the above referenced Texas Pollutant Discharge Elimination System (TPDES) permit. Enclosed you will find one original and three complete copies for your approval. The application fee has.been submitted directly to the Financial Administration Division under separate cover, however, a copy of the fee submitta9l is presented in Attachment A.
If you have any questions concerning this ýappl!tation, please contact me at 512-326-5859... We look forward to working with. you In prooessing this application. Thank you for your consideration, Sincerely, Tres Koenings Senior Consultant I
UnIted States IlCan~ada.l0razi I UK I.lIr~land I N~etherlands Austealla A.91a.Pbocflo I Rusela I Middle East I Africa Atnonebir of RPS. Groulp P/C
 
Attachment NOC-AE-14003142 Page 3 of 155 TABLE OF CONTENTS TCEQ Industrial Wastewater Permit Application TPDES Permit No. WQ0001908000 Submission Checklist Industrial Administrative Report 1.0 Industrial Administrative Report 1.1 Supplemental Permit Information Form Industrial Technical Report 1.0 Worksheet 1.0 EPA Effluent Guidelines Worksheet 2.0 Pollutant Analyses Requirements Worksheet 4.0 Receiving Waters Worksheet 5.0 Sewage Sludge Management and Disposal Worksheet 7.0 Storm Water Runoff Attachment A      Copy of Application Fee (Submission Checklist, Pg.. 1)
Attachment B      USGS Map (Admin Report 1.0 - 8.m., Pg. 12)
Attachment C      Affected Landowners (Admin Report 1.1 - l.a. & b., Pg. 15)
Attachment D      Original Photographs (Admin Report 1.1-          2., Pg. 12)
Attachment E      USGS Map (SPIF, Item 8)
Attachment F      Wastewater Generating Process (Tech Report 1.0 1 .c., Pg. 1)
Attachment G      Facility Plot Plan (Tech Report 1.0 - I.e., Pg. 2)
Attachment H      Flow Schematic Diagrams (Tech Report 1.0 - 2.b., Pg. 3)
Attachment I      Water Treatment Chemicals (Tech Report 1.0 - 5.c., Pg. 8)
Attachment J      Requested Permit Amendments (Admin Report 1.0, Pg. 1; Tech Report 1.0 -12., Pg. 11)
Attachment K Treatment System (Tech Report, Item 2. a., Pg. 3)
J:\Projects\STP Nuclear\Application\STP Nuclear Amendment with Renewal Application~doc
 
Attachment NOC-AE-14003142 Page 4 of 155 Submission Checklist
 
Attachment NOC-AE-14003142 Page 5 of 155 TEXAS COMMISSION ON ENVIRONMENTAL QUALITY TCEQ INDUSTRIAL WASTEWATER PERMIT APPLICATION INDUSTRIAL ADMINISTRATiVE REPORT Submit this checklist with the application. Do not submit the instructionswith the application.Indicateif thefollowing are included in the application.
Applicant STP Nuclear Operating Company Permit Number WQ0001 908000 Administrative Report 1.o              W              Worksheet 7.0                                W    E Administrative Report 1.1              F7f JF          Worksheet 8.0                                F71 -
SPIF                                    i    [7]      Worksheet 9.o                            17      Li Technical Report 1.0                        .          Worksheet 0o.o0]                                  [
Worksheet 1.o                                        . original OF]      USGS Map                              El Worksheet 2.0  -                              [-I. Affected Landowners Map                      .    -
Worksheet 3.0                          EL      i:Y Landowner Disk or Labels                        ,    -] I1 Worksheet 3.1                          1-      []      Copy of Application Fee Check.              V    01 Worksheet3.2                                  F-/    "All fees owed TCEQ are paid                Z      DI Worksheet 3.3                          []        [] Flow Diagram Worksheet 4.0                          [ ,      _      Site Drawing Worksheet 4.11                                          Original Photographs ..                              _
Worksheet 5.0                              i      _, Solids Management Plan                    FE] I Worksheet 6.0                        ].-      L2] Water Balance                                0J rV Please indicate by a check mark the amount submi tted for the application fee: See Attachment A elld...:                  -ajoo Mnor          ".:...
or&med.          ..
  .PA dassificatori                    New                      ond              Rwieid Withut.Qnl                        /-M 0d.
Minor facility not subject to categorical standards                ____$350              -___$350            ____$315              -___$150 promulgated by the EPA (40 CFR Part 4oo-471)
Minor facility subject to categorical standards                ____$1,250            -___$1250          ____$12-15      ____$150 promulgated by the EPA (40 CFR Part 400-471)                                                                                ______
Major facility                          N/A *              Ž..$2,050            __    _$2-,015      -    $450
    '~All facilities are designated as minors until formally classified as a major by EPA.
  -For C~fifimissioim Use 'Only-Se.ge'nieit Nunbr:bt:,                                  §                            ICuny prtlnDte:_______
Troposed/CurrentlrI'emt N~ub&': __________ei I
TCEQ-1 0411 (9/1/2010) Industrial Wastewater Permit Application - Administrative Report                  Page 1 of 18
 
Attachment NOC-AE-14003142 Page 6 of 155 Industrial Administrative Report 1.0


Analyses Requirements Worksheet
Attachment NOC-AE-14003142 Page 7 of 155 INDUSTRIAL ADMINISTRATIE REPORT 1.O The following is requiredforall applications--Renewal,New, And Amendment Type of application:
B NewTPDES                                                    j NewTLAP Major amendment with Renewal                              Major Amendment without Renewal
' Renewal of existing permit                              EJ Stormwater only discharge M Minor amendment to permit                                0 Minor modification to permit If applying for an amendment to a permit, please describe the request in detail. See Attachment J
-The applicant Is requesting the removal of effluent limitations and monitoring requirements for Outfalls 002-006, Relief Well Monitoring Ouffalls.
-The applicant Is requesting the removal of pH monitoring requirements at Internal Outfalls 101, 201, and 501.
: a. Facility Owner (Owner of the facility must apply for the permit.)
What is the Legal Name of the entity (applicant) applying for this permit?
STP Nuclear Operating Company (The legal name must be spelled exactly asfiled with the Texas Secretary of State, County, or in the legal document forming the entity.)
If the applicant is currently a customer with TCEQ, what is the Customer Number (CN)? Search for your CN at:
http:/!wwwV2.tceq.texas.gov/crpub/index.cfm?fuseaction=cust.CustSearch CN601658669 What is the name and title of the person signing the application?
(The person must be an executive official meeting signatory requirements in TAC 305.43(a).)
Prefix (Mr. Ms, Miss): Mr.
First/Last Name: Michael P. Murray Suffix:


===4.0 Receiving===
==Title:==
Manager, Regulatory Affairs                        Credential:
What is the applicant's mailing address as recognized by the US Postal Service?
You may verify the address at: http://zip4.usps.com/zip4/welcome.Isp Organization Name: STP Nuclear Operating Company Mailing Address: P.O. Box 289 Internal Routing (Mail Code, Etc.): N6016 City: Wadsworth                                  State: Xx                        ZIP Code: 77483 Mailing Information if outside USA Territory:                        Country Code:                        Postal Code:
Phone No.: (361)    072-8164                  Extension:_
Fax No.:                                        E-mail Address:
TCEQ-10411 (911/2010) Industrial Wastewater Permit Application - Administrative Report                    Page 2 of 18


Waters Worksheet
Attachment NOC-AE-14003142 Page 8 of 155 Indicate the type of Customer:
[ Individual                                        El Sole Proprietorship-D.B.A.
[ Limited Partnership                                El Corporation
[ Trust                                              C3 Estate
[ Federal Government                                El State Government C County Government                                  Cj City Government C Other Government                                  ED Other:
Independent entity E Yes E] No (If governmental entity; subsidiary,or partof a largercoiporation)
Number of Empio es:
E0-20;            [    21-100;            o 101-250;        Lj  251-500; or      7 501 or higher Customer Business Tax and Filing Numbers (Not applicable to individuals, governments, general partnershipsor sole proprietors.REQUIREDfor corporationsand limited partnerships)
State Franchise Tax ID Number: 1-76-0517597-9 TX SOS Charter (filing) Number: 1459553-01 Federal Tax ID:
DUNS Number (if known):
: b. Co-Permittee information (complete only if the operator must be a co-permittee)
What is the Legal Name of the entity (operator) applying for this permit?
Operator N/A (The legal name must be spelled exactly as filed with the Texas Secretary of State, County, or in the legal documentforming the entity.)
If the operator is currently a customer with TCEQ, what is the Customer Number (CN)? Search for your CN at:
http://www12.tceq.texas.gov/crpub/index.cfm?fLiseaction=cust.CustSearch CN.
What is the name and title of the person signing the application?
(The person must be an executive official meeting signatory requirements in TAC 305.43(a).)
Prefix (Mr. Ms, Miss):
First/Last Name:
Suffix:


===5.0 Sewage===
==Title:==
Sludge Management and Disposal Worksheet
Credential:
What is the applicant's mailing address as recognized by the US Postal Service?
You may verify the address at: http: //zip4.usps.com/zip4/welcome.jsD TCEQ-10411 (9/1/2010) Industrial Wastewater Permit Application - Administrative Report        Page 3 of `18


===7.0 Storm===
Attachment NOC-AE-14003142 Page 9 of 155 Organization Name:
Water Runoff Attachment A Copy of Application Fee (Submission Checklist, Pg.. 1)Attachment B USGS Map (Admin Report 1.0 -8.m., Pg. 12)Attachment C Affected Landowners (Admin Report 1.1 -l.a. & b., Pg. 15)Attachment D Original Photographs (Admin Report 1.1- 2., Pg. 12)Attachment E USGS Map (SPIF, Item 8)Attachment F Wastewater Generating Process (Tech Report 1.0 1 .c., Pg. 1)Attachment G Facility Plot Plan (Tech Report 1.0 -I.e., Pg. 2)Attachment H Flow Schematic Diagrams (Tech Report 1.0 -2.b., Pg. 3)Attachment I Water Treatment Chemicals (Tech Report 1.0 -5.c., Pg. 8)Attachment J Requested Permit Amendments (Admin Report 1.0, Pg. 1; Tech Report 1.0 -12., Pg. 11)Attachment K Treatment System (Tech Report, Item 2. a., Pg. 3)J:\Projects\STP Nuclear\Application\STP Nuclear Amendment with Renewal Application~doc Attachment NOC-AE-14003142 Page 4 of 155 Submission Checklist Attachment NOC-AE-14003142 Page 5 of 155 TEXAS COMMISSION ON ENVIRONMENTAL QUALITY TCEQ INDUSTRIAL WASTEWATER PERMIT APPLICATION INDUSTRIAL ADMINISTRATiVE REPORT Submit this checklist with the application.
Mailing Address:
Do not submit the instructions with the application.
Internal Routing (Mail Code, Etc.):__
Indicate if thefollowing are included in the application.
City:                                         State:                             ZIP Code:
Applicant STP Nuclear Operating Company Permit Number WQ0001 908000 Administrative Report 1.o W Worksheet 7.0 W E Administrative Report 1.1 F7f JF Worksheet 8.0 F71 -SPIF i [7] Worksheet 9.o 17 Li Technical Report 1.0 .Worksheet 0o.o0] [Worksheet 1.o OF] .original USGS Map El Worksheet 2.0 -[-I. Affected Landowners Map .-Worksheet 3.0 EL i:Y Landowner Disk or Labels , -] I1 Worksheet 3.1 1- [] Copy of Application Fee Check. V 01 Worksheet3.2 F-/ " All fees owed TCEQ are paid Z DI Worksheet 3.3 [] [] Flow Diagram Worksheet 4.0 [ , _ Site Drawing Worksheet 4.11 Original Photographs
Mailing Information if outside USA Territory:                         Country Code: _Postal                       Code.,
.._Worksheet 5.0 i _, Solids Management Plan FE] I Worksheet 6.0 ].- L2] Water Balance 0J rV tted for the application fee: See Attachment A Please indicate by a check mark the amount submi-ajoo elld...: ".:...or&med. ..Mnor.PA dassificatori New Rwieid ond Withut.Qnl
Phone No.:                             ____ Extension:
/-M 0d.Minor facility not subject to categorical standards
Fax No.,                                       E-mail Address:
____$350 -___$350 ____$315 -___$150 promulgated by the EPA (40 CFR Part 4oo-471)Minor facility subject to categorical standards
Indicate the type of Customer:
____$1,250
E] Individual                                       [   Sole Proprietorship-D.B.A.
-___$1250
El Limited Partnership                             D Corporation l Trust                                             t Estate D Federal Government                               E State Government t* County Government                                fl City Government
____$12-15
[* Other Government                                  l Other:
____$150 promulgated by the EPA (40 CFR Part 400-471) ______Major facility N/A * ..$2,050
Independent entity 0 Yes E3 No (If governmentalentity, subsidiary,or partof a largercorporation)
__ _$2-,015 -$450'~All facilities are designated as minors until formally classified as a major by EPA.-For C~fifimissioim Use 'Only-Se.ge'nieit Nunbr:bt:, ICuny § prtlnDte:_______
Troposed/Currentlr I'emt N~ub&': __________ei I TCEQ-1 0411 (9/1/2010)
Industrial Wastewater Permit Application
-Administrative Report Page 1 of 18 Attachment NOC-AE-14003142 Page 6 of 155 Industrial Administrative Report 1.0 Attachment NOC-AE-14003142 Page 7 of 155 INDUSTRIAL ADMINISTRATIE REPORT 1.O The following is requiredfor all applications--Renewal, New, And Amendment Type of application:
B NewTPDES j NewTLAP Major amendment with Renewal Major Amendment without Renewal' Renewal of existing permit EJ Stormwater only discharge M Minor amendment to permit 0 Minor modification to permit If applying for an amendment to a permit, please describe the request in detail. See Attachment J-The applicant Is requesting the removal of effluent limitations and monitoring requirements for Outfalls 002-006, Relief Well Monitoring Ouffalls.-The applicant Is requesting the removal of pH monitoring requirements at Internal Outfalls 101, 201, and 501.a. Facility Owner (Owner of the facility must apply for the permit.)What is the Legal Name of the entity (applicant) applying for this permit?STP Nuclear Operating Company (The legal name must be spelled exactly as filed with the Texas Secretary of State, County, or in the legal document forming the entity.)If the applicant is currently a customer with TCEQ, what is the Customer Number (CN)? Search for your CN at: http:/!wwwV2.tceq.texas.gov/crpub/index.cfm?fuseaction=cust.CustSearch CN601658669 What is the name and title of the person signing the application?(The person must be an executive official meeting signatory requirements in TAC 305.43(a).)
Prefix (Mr. Ms, Miss): Mr.First/Last Name: Michael P. Murray Suffix: Title: Manager, Regulatory Affairs Credential:
What is the applicant's mailing address as recognized by the US Postal Service?You may verify the address at: http://zip4.usps.com/zip4/welcome.Isp Organization Name: STP Nuclear Operating Company Mailing Address: P.O. Box 289 Internal Routing (Mail Code, Etc.): N6016 City: Wadsworth State: Xx ZIP Code: 77483 Mailing Information if outside USA Territory:
Country Code: Postal Code: Phone No.: (361) 072-8164 Extension:_
Fax No.: E-mail Address: TCEQ-10411 (911/2010)
Industrial Wastewater Permit Application
-Administrative Report Page 2 of 18 Attachment NOC-AE-14003142 Page 8 of 155 Indicate the type of Customer:[ Individual
[ Limited Partnership
[ Trust[ Federal Government C County Government C Other Government El Sole Proprietorship-D.B.A.
El Corporation C3 Estate El State Government Cj City Government ED Other: Independent entity E Yes E] No (If governmental entity; subsidiary, or part of a larger coiporation)
Number of Empio es: E0-20; [ 21-100;o 101-250;Lj 251-500; or 7 501 or higher Customer Business Tax and Filing Numbers (Not applicable to individuals, governments, general partnerships or sole proprietors.
REQUIRED for corporations and limited partnerships)
State Franchise Tax ID Number: 1-76-0517597-9 TX SOS Charter (filing) Number: 1459553-01 Federal Tax ID: DUNS Number (if known): b. Co-Permittee information (complete only if the operator must be a co-permittee)
What is the Legal Name of the entity (operator) applying for this permit?Operator N/A (The legal name must be spelled exactly as filed with the Texas Secretary of State, County, or in the legal document forming the entity.)If the operator is currently a customer with TCEQ, what is the Customer Number (CN)? Search for your CN at: http://www12.tceq.texas.gov/crpub/index.cfm?fLiseaction=cust.CustSearch CN.What is the name and title of the person signing the application?(The person must be an executive official meeting signatory requirements in TAC 305.43(a).)
Prefix (Mr. Ms, Miss): First/Last Name: Suffix: Title: Credential:
What is the applicant's mailing address as recognized by the US Postal Service?You may verify the address at: http: //zip4.usps.com/zip4/welcome.jsD TCEQ-10411 (9/1/2010)
Industrial Wastewater Permit Application
-Administrative Report Page 3 of `18 Attachment NOC-AE-14003142 Page 9 of 155 Organization Name: Mailing Address: Internal Routing (Mail Code, Etc.):__City: State: ZIP Code: Mailing Information if outside USA Territory:
Country Code: _Postal Code., Phone No.: ____ Extension:
Fax No., E-mail Address: Indicate the type of Customer: E] Individual  
[ Sole Proprietorship-D.B.A.
El Limited Partnership D Corporation l Trust t Estate D Federal Government E State GovernmentCounty Government fl City GovernmentOther Government l Other: Independent entity 0 Yes E3 No (If governmental entity, subsidiary, or part of a larger corporation)
Number of Employees:
Number of Employees:
0-20; 21-100; E 101-250; 0 251-500; or E 501 or higher Customer Business Tax and Filing Numbers (Not applicable to individuals, governments, general partnerships or sole proprietors.
0-20;             21-100;     E 101-250;           0   251-500; or       E   501 or higher Customer Business Tax and Filing Numbers (Not applicableto individuals, governments, generalpartnershipsor sole proprietors.REQUIREDfor corporationsand limited partnerships)
REQUIRED for corporations and limited partnerships)
State Franchise Tax ID Number:
State Franchise Tax ID Number: TX SOS Charter (filing) Number: Federal Tax ID: DUNS Number (if known): Provide a brief description of the need for a co-permittee:
TX SOS Charter (filing) Number:
TCEQ-10411.  
Federal Tax ID:
(9/1/2010)
DUNS Number (if known):
Industrial Wastewater Permit Application -Administrative Report Page 4 of 18 Attachment NOC-AE-14003142 Page 10 of 155 c. Individual information (complete only if thefacility owner or co-permittee is an individual)
Provide a brief description of the need for a co-permittee:
What is the Legal Name of the owner/co-permittee applying for this permit?N/A If the owner/co-permittee is currently a customer with TCEQ, what is the Customer Number (CN)? Search for your CN at: http:!/wwwl2.tceg.texas.gov/crpub/index.cfm?fuseaction=cust.CustSearch CN What is the name and title of the person signing the application?(The person must be the individual.
TCEQ-10411. (9/1/2010) Industrial Wastewater Permit Application -Administrative Report             Page 4 of 18
See signatoly requirements in TAC 305.43(a).)
 
Prefix (Mr. Ms, Miss):.First/Last Name: Suffix: State Identification Number: Date of Birth: Assumed business or professional name: Business name: What is the applicant's mailing address as recognized by the US Postal Service?You may verify the address at: http://zip4.usps.com/ziP4/welcome.'sm Mailing Address: Internal Routing (Mail Code, Etc.): City: State: TX ZIP Code:.Mailing Information if outside USA Territory:
Attachment NOC-AE-14003142 Page 10 of 155
Country Code: _Postal Code: Phone No.: Extension:
: c. Individual information (complete only if thefacility owner or co-permittee is an individual)
Fax No.: E-mail Address: a. Billing Contact and Address Information The permittee is responsible for paying the annual fee. The annual fee will be assessed to permits active on September 1 of each year. TCEQ will send a bill to the address provided in this section. The permittee is responsible for terminating the permit when it is no longer needed.Is the billing address the same as the permittee or co-permittee?
What is the Legal Name of the owner/co-permittee applying for this permit?
E] Permittee  
N/A If the owner/co-permittee is currently a customer with TCEQ, what is the Customer Number (CN)? Search for your CN at:
[ Co-permittee l No, fill out this section Prefix (Mr, Ms, Miss): Mr.First/Last Name: John Hoffman Suffix: Title: Staff Environmental Consultant Credential:_
http:!/wwwl2.tceg.texas.gov/crpub/index.cfm?fuseaction=cust.CustSearch CN What is the name and title of the person signing the application?
Organization Name: STP Nuclear Operating Company Billing Mailing Address: P.O. Box 289 TCEQ-10411 (9/1/2010)
(The person must be the individual. See signatoly requirements in TAC 305.43(a).)
Industrial Wastewater Permit Application  
Prefix (Mr. Ms, Miss):.
-Administrative Report Page 6 of 18 Attachment NOC-AE-14003142 Page 11 of 155 Internal Routing (Mail Code, Etc.): N2019 City: Wadsworth State: TX ZIP Code: 77483 Mailing Information if outside USA.Territory:.
First/Last Name:
Country Code: Postal Code: Phone No.: (361) 972-4507 Extension:
Suffix:
Fax No.: E-mail Address: jphoffman@stpegs.eom If TCEQ needs additional information regarding this application, who should be contacted?
State Identification Number:
: a. Application Contact Prefix (Mr. Ms, Miss): Mr.First/Last Name: John Hoffman Suffix: Title: Staff Environmental Consultant Credential:
Date of Birth:
Organization Name: STP Nuclear Operating Company Mailing Address: P.O. Box 289 Internal Routing (Mail Code, Etc.): N201 9 City: Wadsworth State: TX ZIP Code: 77483 Mailing Information if outside USA.Territory:
Assumed business or professional name:
Country Code: Postal Code: Phone No.: (361) 972-4507 Extension:
Business name:
Fax No.: E-mail Address: Jphoffman@stpegs.com Check one or both: F Administrative contact n/ Technical Contact b. Application Contact Prefix (Mr. Ms, Miss): Mr.First/Last Name: Tres Koenings Suffix: Title:. Senior Consultant Credential:
What is the applicant's mailing address as recognized by the US Postal Service?
Organization Name: RPS Mailing Address: 4801 Southwest Parkway, Parkway 2, Suite 150 Internal Routing (Mail Code, Etc.): City: Austin State: TX ZIP Code: 78735 Mailing Information if outside USA.Territory:
You may verify the address at: http://zip4.usps.com/ziP4/welcome.'sm Mailing Address:
Country Code: Postal Code: Phone No.: (512) 326-56L9 Extension:
Internal Routing (Mail Code, Etc.):
Fax No.: E-mail Address: tres.koenlngs@rpsgroup.com Check one or both: : F Administrative contact 0 Technical Contact TCEQ-1 0411 (9/1/2010)
City:                                         State: TX                           ZIP Code:.
Industrial Wastewater Permit Application  
Mailing Information if       outside   USA Territory:                         Country Code: _Postal                       Code:
-Administrative Report Page 6 of 18 Attachment NOC-AE-14003142 Page 12 of 155% '?. .. ........ ',¢  
Phone No.:                                     Extension:
........ i''": '='.; " i"... "......."...
Fax No.:                                       E-mail Address:
..... ..... ....... ... .... .... .. ... .....-,'ii:
: a. Billing Contact and Address Information The permittee is responsiblefor paying the annualfee. The annualfee will be assessed to permits active on September 1 of each year. TCEQ will send a bill to the addressprovided in this section. The permittee is responsiblefor terminatingthe permit when it is no longer needed.
~  Contact Responsible for Discharge Monitoring Reports (EPA 3320-1) Provide the name of the person and their complete mailing address delegated to receive and submit Discharge Monitoring Report Forms.Prefix (Mr. Ms, Miss): Mr.First/Last Name: John Hoffman Suffix: Title: Staff Environmental Consultant Credential:
Is the billing address the same as the permittee or co-permittee?
Organization Name:, STP Nuclear Operating Company Mailing Address: pKo. Box 289 Internal Routing (Mail Code, Etc.): N2019 City: Wadsworth State: TX ZIP Code: 77843 Mailing Information if outside USA.Territory:
E] Permittee             [ Co-permittee                 l No, fill out this section Prefix (Mr, Ms, Miss): Mr.
Country Code: Postal Code: Phone No.: (361) 972-4507 Extension:
First/Last Name: John Hoffman Suffix:
Fax No. E-mail Addre-ss jphoffman stpegs.com letl-zb Did you know you can submit DMR data on line?Go to Sign up now at: https: /!www6.tceq.texas.gov/steers/
 
Establish an electronic reporting account when you get your permit number.Provide two names of individuals that can be contacted throughout the permit term.Prefix (Mr. Ms, Miss): Mr.First/Last Name: John Hoffman Q, , ATIA4 ."UXLAA, Title: Staff Environmental Consultant Credei Organization Name: STP Nuclear Operating Company Mailing Add'ess: P.O. Box 289 Internal Routing (Mail Code, Etc.): N2019 City: Wadsworth State: TX ZIP Code: 77843 Mailing Information if outside USA.Territory:
==Title:==
Country Code: Postal Code: Phone No.: (361) 972-4507 Extension:
Staff Environmental Consultant                   Credential:_
Fax No.: E-mail Address: Jphoffman@stpegs.com TCEQ-10411 (911/2010)
Organization Name: STP Nuclear Operating Company Billing Mailing Address: P.O. Box 289 TCEQ-10411 (9/1/2010) Industrial Wastewater Permit Application - Administrative Report           Page 6 of 18
Industrial Wastewater Permit Application  
 
-Administrative Report Page 7 of 18 Attachment NOC-AE-14003142 Page 13 of 155 Prefix (Mr. Ms, Miss): Ms.First/Last Name: P.L. Travis Suffix: Title: Environmental Supervisor Credential:
Attachment NOC-AE-14003142 Page 11 of 155 Internal Routing (Mail Code, Etc.): N2019 City: Wadsworth                                 State: TX                           ZIP Code: 77483 Mailing Information if outside USA.
Organization Name: STP Nuclear Operating Company Mailing Address: P.O. Box 289 Internal Routing (Mail Code, Etc.): N2019 City: Wadsworth State: TX ZIP Code: 77843 Mailing Information if outside USA.Territory:
Territory:.                     Country Code:                       Postal Code:
Country Code: Postal Code: Phone No.: (361) 972-8573 Extension:
Phone No.: (361) 972-4507                       Extension:
Fax No.: E-mail Address: pltravls@stpegs.com
Fax No.:                                       E-mail Address: jphoffman@stpegs.eom If TCEQ needs additional information regarding this application, who should be contacted?
: a. Individual publishing the notices Prefix (Mr. Ms, Miss): Mr.First/Last Name: John Hoffman Suffix: Title: Staff Environmental Consultant Credential:__
: a. Application Contact Prefix (Mr. Ms, Miss): Mr.
Organization Name: STP Nuclear Operating Company Mailing Address: P.O. Box 289 Internal Routing (Mail Code, Etc.): N2019 City: Wadsworth .State: TX ZIP Code: 77843 Mailing Information if outside USA.Territory:
First/Last Name: John Hoffman Suffix:
Country Code: Postal Code:_Phone No.: (361) 972-4507 Extension:
 
Fax No.: E-mail Address: jphoffman@stpegscom
==Title:==
Staff Environmental Consultant                   Credential:
Organization Name: STP Nuclear Operating Company Mailing Address: P.O. Box 289 Internal Routing (Mail Code, Etc.):         N201 9 City: Wadsworth                                 State: TX                           ZIP Code: 77483 Mailing Information if outside USA.
Territory:                       Country Code:                       Postal Code:
Phone No.: (361) 972-4507                       Extension:
Fax No.:                                       E-mail Address: Jphoffman@stpegs.com Check one or both:           F Administrative contact                 n/ Technical Contact
: b. Application Contact Prefix (Mr. Ms, Miss): Mr.
First/Last Name: Tres Koenings Suffix:
 
==Title:==
. Senior Consultant                               Credential:
Organization Name: RPS Mailing Address: 4801 Southwest Parkway, Parkway 2, Suite 150 Internal Routing (Mail Code, Etc.):
City: Austin                                   State: TX                           ZIP Code: 78735 Mailing Information if outside USA.
Territory:                       Country Code:                       Postal Code:
Phone No.: (512) 326-56L9                       Extension:
Fax No.:                                       E-mail Address: tres.koenlngs@rpsgroup.com Check one or both: :             F Administrative contact               0 Technical Contact TCEQ-1 0411 (9/1/2010) Industrial Wastewater Permit Application - Administrative Report             Page 6 of 18
 
Attachment NOC-AE-14003142 Page 12 of 155
            !*:¢
                % *.i!='
                      * :*."'?........... ',¢ *' *""-¢"**"i"! ........ i''":.....
                      *"                                                    '='.;
:~i":!*''''*'*=''-'
i"...
                                                                                                            "......."...                                 ~i**i
                                                                                                                                    *!?*~ii*-,'ii:?:!'.:*:.*:!
Contact Responsible for Discharge Monitoring Reports (EPA 3320-1) Provide the name of the person and their complete mailing address delegated to receive and submit Discharge Monitoring Report Forms.
Prefix (Mr. Ms, Miss): Mr.
First/Last Name: John Hoffman Suffix:
 
==Title:==
Staff Environmental Consultant                                                     Credential:
Organization Name:, STP Nuclear                                   Operating         Company Mailing Address: pKo. Box 289 Internal Routing (Mail Code, Etc.): N2019 City: Wadsworth                                                           State: TX                                   ZIP Code: 77843 Mailing Information if outside USA.
Territory:                                             Country Code:                               Postal Code:
Phone No.: (361) 972-4507                                                                 Extension:
Fax No.                                                                                   E-mail Addre-ss jphoffman stpegs.com Did you know you can submit DMR data on line?
Go to Sign up now at:
letl-zb              https: /!www6.tceq.texas.gov/steers/
Establish an electronic reporting account when you get your permit number.
Provide two names of individuals that can be contacted throughout the permit term.
Prefix (Mr. Ms, Miss): Mr.
First/Last Name: John Hoffman Q, , ATIA4 .
"UXLAA,
 
==Title:==
Staff Environmental Consultant                                                     Credei Organization Name: STP Nuclear Operating Company Mailing Add'ess: P.O. Box 289 Internal Routing (Mail Code, Etc.): N2019 City: Wadsworth                                                           State: TX                                   ZIP Code: 77843 Mailing Information if outside USA.
Territory:                                             Country Code:                               Postal Code:
Phone No.: (361) 972-4507                                                                 Extension:
Fax No.:                                                                                 E-mail Address: Jphoffman@stpegs.com TCEQ-10411 (911/2010) Industrial Wastewater Permit Application - Administrative Report                                                     Page 7 of 18
 
Attachment NOC-AE-14003142 Page 13 of 155 Prefix (Mr. Ms, Miss): Ms.
First/Last Name: P.L. Travis Suffix:
 
==Title:==
Environmental Supervisor                   Credential:
Organization Name: STP Nuclear Operating Company Mailing Address: P.O. Box 289 Internal Routing (Mail Code, Etc.): N2019 City: Wadsworth                           State: TX                           ZIP Code: 77843 Mailing Information if outside USA.
Territory:                       Country Code:                               Postal Code:
Phone No.: (361) 972-8573                         Extension:
Fax No.:                                         E-mail Address: pltravls@stpegs.com
: a. Individual publishing the notices Prefix (Mr. Ms, Miss): Mr.
First/Last Name: John Hoffman Suffix:
 
==Title:==
Staff Environmental Consultant                   Credential:__
Organization Name: STP Nuclear Operating       Company Mailing Address:       P.O. Box 289 Internal Routing (Mail Code, Etc.): N2019 City: Wadsworth                                       .State: TX                   ZIP Code: 77843 Mailing Information if outside USA.
Territory:                   Country Code:                       Postal Code:_
Phone No.: (361) 972-4507                               Extension:
Fax No.:                                       E-mail Address: jphoffman@stpegscom
: b. Method for receiving Notice of Receipt and Intent to Obtain a Water Quality Permit Package Indicate by a check mark the preferred method for receiving the first notice and instructions:
: b. Method for receiving Notice of Receipt and Intent to Obtain a Water Quality Permit Package Indicate by a check mark the preferred method for receiving the first notice and instructions:
[21 E-mail Address: Jphoffman@stpegs.com
[21 E-mail Address: Jphoffman@stpegs.com
[] Fax No.: El Overnight/Priority mail: (self addressed, prepaid envelope required)[] Regular Mail: Mailing Address: Internal Routing (Mail Code, Etc.):_City: State: TX ZIP Code: c. Contact in the Notice TCEQ-10411 (911/2010)
[] Fax No.:
Industrial Wastewater Permit Application  
El Overnight/Priority mail: (self addressed, prepaid envelope required)
-Administrative Report Page 8 of 18 Attachment NOC-AE-14003142 Page 14 of 155 Prefix (Mr. Ms, Miss): Mr.First/Last Name: John Hoffman Suffix: Title: Staff Environmental Consultant Credential:
[] Regular Mail:
Organization Name: STP Nuclear Operating Company Phone No.: (361) 972-4507 Extension:
Mailing Address:
: d. Public Place Information If thefacility and/or outfall are located in more than one county, a public viewing place for each county must be provided.Public Building name: Matagorda County Courthouse Location within the building:
Internal Routing (Mail Code, Etc.):_
County Clerks Office Physical address of building:
City:                                           State: TX                 ZIP Code:
1700 7th Street City: Bay City County: Matagorda Contact Name: Janet Hlckl Phone No.: (970) 244-7680 Extension:
: c. Contact in the Notice TCEQ-10411 (911/2010) Industrial Wastewater Permit Application - Administrative Report             Page 8 of 18
 
Attachment NOC-AE-14003142 Page 14 of 155 Prefix (Mr. Ms, Miss): Mr.
First/Last Name: John Hoffman Suffix:
 
==Title:==
Staff Environmental Consultant                     Credential:
Organization Name: STP Nuclear Operating         Company Phone No.: (361) 972-4507                                 Extension:
: d. Public Place Information If thefacility and/oroutfall are located in more than one county, a public viewing placefor each county must be provided.
Public Building name: Matagorda County Courthouse Location within the building: County Clerks Office Physical address of building: 1700 7th Street City: Bay City                                                   County: Matagorda Contact Name: Janet Hlckl Phone No.: (970) 244-7680                                         Extension:
: e. Bilingual Notice Requirements:
: e. Bilingual Notice Requirements:
For new permit, major amendment and renewal applications.
For new permit, major amendment and renewal applications. Not applicable for minor amendment or minor modification applications.
Not applicable for minor amendment or minor modification applications.
Please call the bllingual/ESL coordinator at the nearest elementary and middle schools and obtain the following Information to determine if an alternative language notice is required:
Please call the bllingual/ESL coordinator at the nearest elementary and middle schools and obtain the following Information to determine if an alternative language notice is required: 1. Is a bilingual education program required by the Texas Education Code at the nearest elementary or middle school to the facility or proposed facility?n- Yes nN No (If No, alternative language notice publication is not required; skip to item 7. SITE INFORMATION.)
: 1. Is a bilingual education program required by the Texas Education Code at the nearest elementary or middle school to the facility or proposed facility?
: 2. Are the students who attend either the elementary school or the middle school enrolled in a bilingual education program at that school?0 Yes [3 No 3. Do the students at these schools attend a bilingual education program at another location?0 Yes [] No 4. Would the school be required to provide a bilingual education program but the school has waived out of this requirement under 19 TAC §89.1205(g)?
n- Yes         nN No           (If No, alternative language notice publication is not required; skip to item 7. SITE INFORMATION.)
[7 Yes 0 No 5. If the answer is yes to 1, 2, 3, or 4, public notice in an alternative language is required.
: 2. Are the students who attend either the elementary school or the middle school enrolled in a bilingual education program at that school?
Which language is required by the bilingual program?This section of the application is only used to determine if alternative language notice will be needed. Complete instructions on publishing the alternative language notice will be in your public notice package.TCEQ-1 0411 (9/1/2010)
0 Yes         [3 No
Industrial Wastewater Permit Application  
: 3. Do the students at these schools attend a bilingual education program at another location?
-Administrative Report Page 9 of 18 Attachment NOC-AE-14003142 Page 15 of 155 If the site of your business is part of a larger business site, a Regulated Entity Number (RN) may already be assigned for the larger sitt. Use the RN assigned for the larger site. Search TCEQ's Central Registry to see if the larger site may already be registered as a regulated site at: http: //wwwl2.tceeq.texas.gov/crpub/index.cfm?ftseaction=regent.RNSearch If the site is found, provide the assigned Regulated Entity Reference Number and provide the information for the site to be authorized through this application below.The site information for this authorization may vary from the larger site information.
0 Yes         [] No
TCEQ issued RE Reference Number (RN): RN 102395654 a. State/TPDES Permit No.: WQ0001908000 Expiration date: 12/01/2014 EPA Identification No. (TPDES Permits only): TX 0 0 6 4 9 4 7 b. Name of project or site (the name kmown by the community where located): South Texas Project Electric Generating Station c. Is the facility located in Bexar Comal Hays, Kinney, Medina, Travis, Uvalde, or Williamson County? l Yes lNo (If Yes, additional Information concerning protection of the Edwards Aquifer may be required.)
: 4. Would the school be required to provide a bilingual education program but the school has waived out of this requirement under 19 TAC §89.1205(g)?
: d. Is the location of the facility used in the existing permit correct? ED Yes ONo e. Does the site have a physical address?If Yes, complete Section A for a physical address.If No (the location description is not accurate or this is a new permit application, complete), complete Section B for site location information.
[7 Yes         0 No
Se~ction, A; E addre~s for thg~le, :' ,,: -,. ' - Verify the address with USPS. If the address is not recognized as a delivery address, provide the address as identified for overnight mail delivery, 911 emergencies, or other online map tool to confirm an address.Physical Address of Project or Site: Street Number: 12090 Street Name: Farm-to-Market Road 521 City: Wadsworth ZIP Code: 77483 Seck~ns~ ute t e ri~-~cto iomatln, If no physical address (Street Number & Street Name), provide a written location access description to the site: I (Ex.: located 2 miles west from intersection of Hwy 29o & IH35 accessible on Hwy 29o South)TCEQ-10411 (9/1/2010)
: 5. If the answer is yes to 1, 2, 3, or 4, public notice in an alternative language is required. Which language is required by the bilingual program?
Industrial Wastewater Permit Application  
This section of the applicationis only used to determine if alternative language notice will be needed. Complete instructionson publishing the alternative languagenotice will be in your public noticepackage.
-Administrative Report Page 10 of 18 Attachment NOC-AE-14003142 Page 16 of 155 f. City where the site is located or, if not in a city, what is the nearest city: Wadsworth g. ZIP Code where the site is located: 77483 h. County where the site is located Matagorda i. Latitude:
TCEQ-1 0411 (9/1/2010) Industrial Wastewater Permit Application - Administrative Report   Page 9 of 18
28' 47' 50" N Longitude:
 
96' 03' 10" W j. In your own words, briefly describe the primary business of the Regulated Entity: (Do not repeat the SIC and NAICS code)FSteam Electric Generating Facility k. Owner of treatment facility:
Attachment NOC-AE-14003142 Page 15 of 155 If the site of your business is part of a larger business site, a Regulated Entity Number (RN) may already be assigned for the larger sitt. Use the RN assigned for the larger site. Search TCEQ's Central Registry to see if the larger site may already be registered as a regulated site at:
STP Nuclear Operating Company Ownership of Facility:
http: //wwwl2.tceeq.texas.gov/crpub/index.cfm?ftseaction=regent.RNSearch If the site is found, provide the assigned Regulated Entity Reference Number and provide the information for the site to be authorized through this application below.
E Public 1-/ Private ] Both lZLFederal
The site information for this authorization may vary from the larger site information.
: 1. Owner of land where treatment facility is/will be: STP Nuclear Operating Company (If not the same as the facility owner, there must be a long term lease agreement in effect for at least six years. In some cases, a lease may not suffice -see instructions.)
TCEQ issued RE Reference Number (RN): RN 102395654
: m. Owner of effluent disposal site: N/A (If not the same as the facility owner, there must be a long term lease agreement in effect for at least six years.)n. Owner of sewage sludge disposal site: N/A (Required only If authorization is sought in the permit for sludge disposal on property owned/controlled by the applicant.)
: a. State/TPDES Permit No.: WQ0001908000                             Expiration date: 12/01/2014 EPA Identification No. (TPDES Permits only): TX 06 49 47      0
: a. Is the point of discharge and discharge route in the existing permit correct?V1 Yes 0 No If no, or a new or amendment permit application, please give an accurate description.
: b. Name of project or site (the name kmown by the community where located):
N/A b. City or Town in which the outfall(s) is or will be located Near Bay City c. County the outfall(s) is located: Matagorda d. Ogtfate atitud 001:280 44' 48"N Longitude:
South Texas Project Electric Generating Station
001: 960 00' 02"W eee-low foredditional outfalls, e. For all applications involving an average daily discharge of 5 million gallons per day or more, provide the names of all counties located within loo statute miles downstream of the point(s) of discharge.
: c. Is the facility located in Bexar Comal Hays, Kinney, Medina, Travis, Uvalde, or Williamson County?                 l Yes lNo (If Yes, additional Information concerning protection of the Edwards Aquifer may be required.)
N/A*Oultfall 002: 28°46'29"N 950 59' 53" W; Outfall 003: 28°44'49"N 96 0 00'40"W; Outfall 004:28"44'57"N 96001'03";
: d. Is the location of the facility used in the existing permit correct? ED Yes               ONo
Outfall 005: 28 0 44'32"N 96 0 02'42"W; Outfall 006: 28 0 44'31"N 96 0 03'36"W TCEQ-10411 (9/1/2010)
: e. Does the site have a physical address?
Industrial Wastewater Permit Application  
If Yes, complete Section A for a physical address.
-Administrative Report Page 11 of 18 Attachment NOC-AE-14003142 Page 17 of 155 f. If a TLAP, is the location of the effluent disposal site in the existing permit accurate?[ Yes Eu No If no, or a new or amendment permit application, please give an accurate description.
If No (the location description is not accurate or this is a new permit application, complete), complete Section B for site location information.
N/A g. City or Town in which the disposal site is or willbe located N/A h. County the disposal site is located: N/A i. Disposal Site Latitude:
Se~ction, A; E ter:thBph*cal addre~s for thg~le,                  *:<:, :',,: ,. ::,* >*1 ;:::*:!:
N/A Longitude:
Verify the address with USPS. If the address is not recognized as a delivery address, provide the address as identified for overnight mail delivery, 911 emergencies, or other online map tool to confirm an address.
N/A j. If a TLAP, describe the routing of effluent from the treatment facility to the effluent disposal site: N/A k. For TLAP applications please identify the nearest watercourse to the disposal site to which rainfall runoff might flow if not contained:
PhysicalAddress of Projector Site:
N/A 1. Is the location of the sewage sludge disposal site in the existing permit accurate?-Yes r No If no, or a new permit application, please give an accurate description.
Street Number: 12090                             Street Name: Farm-to-Market Road 521 City: Wadsworth                                 ZIP Code: 77483 Seck~ns~ ute t       e               iomatln, ri~-~cto If no physical address (Street Number & Street Name), provide a written location I
N/A m. Provide an original full size USGS Topographic Map with all required information.
access description to the site:
Indicate by a check mark that the information is provided.
(Ex.: located 2 miles west from intersection of Hwy 29o & IH35 accessible on Hwy 29o South)
See Attachment B j Applicant's property boundary D Treatment facility boundaries nN Labeled point of discharge and highlighted discharge route[-] Sewage sludge disposal site-] Effluent disposal site boundaries
TCEQ-10411 (9/1/2010) Industrial Wastewater Permit Application - Administrative Report         Page 10 of 18
[j New and future construction on i mile radius and 3 miles downstream information V All ponds n. Is/will the treated wastewater discharge to a city, county, or state highway right-of-way, or a flood control district drainage ditch? LI Yes [] No If Yes, indicate by a check mark if: N/A[- Authorization granted [I Authorization pending (For new and amendments, provide copies of letters that show proof of contact and the approval letter upon receipt.)TCEQ-10411 (9/1/2010)
 
Industrial Wastewater Permit Application -Administrative Report Page 12 of 18 Attachment NOC-AE-14003142 Page 18 of 155 o. Is the facility located on or does the treated effluent cross American Indian Land?DYes MY No a. List each person formerly employed by the TCEQ who represented your company and was paid for service regarding the application:
Attachment NOC-AE-14003142 Page 16 of 155
Tres Koenings, Jamie Saladiner b. Do you owe fees to the TCEQ? EL Yes 70 No If yes, please provide: Account number: Amount past due: c. Do you owe any penalties to the TCEQ? F] Yes [] No If yes, please provide: Enforcement order number Amount past due TCEQ-10411 (9/1/2010)
: f. City where the site is located or, if not in a city, what is the nearest city:
Industrial Wastewater Permit Application  
Wadsworth
-Administrative Report Page 13 of 18 Attachment NOC-AE-14003142 Page 19 of 155 Permit Number: WQ0001908000 Applicant; STP Nuclear Operating Company Certification:
: g. ZIP Code where the site is located: 77483
I, Michael P. Murray Manager, Regulatory Affairs Typed or printed name Title certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted.
: h. County where the site is located Matagorda
Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete.
: i. Latitude: 28' 47' 50" N                         Longitude: 96' 03' 10" W
I am aware there are significant penalties for submitting false information, including thepossibility of fine and imprisonment for knowing violations.
: j. In your own words, briefly describe the primary business of the Regulated Entity:
I further certify that I am authorized under 30 Texas Administrative Code &sect;305.44 to sign and submit this document, and can provide documentation in proof'of such authorization upon request.Signature:
(Do not repeat the SIC andNAICS code)
Date: 2 (Use l"e k)Subscribed and Sworn to before me by the said- &#xfd;A c\ c\ \ Ctu on this dayof ,20 o2 My commission expires on the LAh- day of I ,2o )WL\ ~ [SEAL]Notary Public County, Texas tf co-permittees are necessary, each entity must submit an original, separate signature page.TCEQ-1041 i (9/1/2010)
FSteam Electric Generating Facility
Industrial Wastewater Permit Application -Administrative Report Page 14 of 18 Attachment NOC-AE-14003142 Page 20 of 155 Industrial Administrative Report 1.1 Attachment NOC-AE-14003142 Page 21 of 155 INDUSTRIAL ADMINISTRATIVE REPORT 1.1 The following is requir'edfor new and amendment applications.
: k. Owner of treatment facility:         STP Nuclear Operating Company Ownership of Facility: E           Public   1-/     Private     ] Both     lZLFederal
See Attachment C a. Indicate by a check mark that the landowners map or drawing, with scale, includes the following, as applicable.
: 1. Owner of land where treatment facility is/will be: STP Nuclear Operating Company (If not the same as the facility owner, there must be a long term lease agreement in effect for at least six years. In some cases, a lease may not suffice - see instructions.)
: m. Owner of effluent disposal site: N/A (If not the same as the facility owner, there must be a long term lease agreement in effect for at least six years.)
: n. Owner of sewage sludge disposal site: N/A (Required only If authorization is sought in the permit for sludge disposal on property owned/controlled by the applicant.)
: a. Is the point of discharge and discharge route in the existing permit correct?
V1 Yes 0 No             If no, or a new or amendment permit application, please give an accurate description.
N/A
: b. City or Town in which the outfall(s) is or will be located Near Bay City
: c. County the outfall(s) is located: Matagorda
: d. Ogtfate atitud 001:280 44' 48"N                           Longitude: 001: 960 00' 02"W eee-low foredditional outfalls,
: e. For all applications involving an average daily discharge of 5 million gallons per day or more, provide the names of all counties located within loo statute miles downstream of the point(s) of discharge. N/A
*Oultfall 002: 28&deg;46'29"N 950 59' 53" W; Outfall 003: 28&deg;44'49"N 96 0 00'40"W; Outfall 004:28"44'57"N 96001'03"; Outfall 005: 28 044'32"N 96 0 02'42"W; Outfall 006: 28 0 44'31"N 96 003'36"W TCEQ-10411 (9/1/2010) Industrial Wastewater Permit Application - Administrative Report       Page 11 of 18
 
Attachment NOC-AE-14003142 Page 17 of 155
: f. If a TLAP, is the location of the effluent disposal site in the existing permit accurate?
[ Yes       Eu No         If no, or a new or amendment permit application, please give an accurate description.
N/A
: g. City or Town in which the disposal site is or willbe located N/A
: h. County the disposal site is located: N/A
: i. Disposal Site Latitude: N/A                               Longitude: N/A
: j. If a TLAP, describe the routing of effluent from the treatment facility to the effluent disposal site:
N/A
: k. For TLAP applications please identify the nearest watercourse to the disposal site to which rainfall runoff might flow if not contained: N/A
: 1. Is the location of the sewage sludge disposal site in the existing permit accurate?
      - Yes r No         If no, or a new permit application, please give an accurate description.
N/A
: m. Provide an original full size USGS Topographic Map with all required information.
Indicate by a check mark that the information is provided. See Attachment B j Applicant's property boundary D Treatment facility boundaries nN Labeled point of discharge and highlighted discharge route
[-] Sewage sludge disposal site
          -] Effluent disposal site boundaries
[j New and future construction on i mile radius and 3 miles downstream information V All ponds
: n. Is/will the treated wastewater discharge to a city, county, or state highway right-of-way, or a flood control district drainage ditch? LI Yes [] No If Yes, indicate by a check mark if:             N/A
[- Authorization granted [I Authorization pending (For new and amendments, provide copies of letters that show proof of contact and the approval letter upon receipt.)
TCEQ-10411 (9/1/2010) Industrial Wastewater Permit Application -Administrative Report   Page 12 of 18
 
Attachment NOC-AE-14003142 Page 18 of 155
: o. Is the facility located on or does the treated effluent cross American Indian Land?
DYes MY No
: a. List each person formerly employed by the TCEQ who represented your company and was paid for service regarding the application:
Tres Koenings, Jamie Saladiner
: b. Do you owe fees to the TCEQ?                 EL Yes 70 No If yes, please provide:
Account number:                                           Amount past due:
: c. Do you owe any penalties to the TCEQ?                     F] Yes           [] No If yes, please provide:
Enforcement order number                                         Amount past due TCEQ-10411 (9/1/2010) Industrial Wastewater Permit Application - Administrative Report   Page 13 of 18
 
Attachment NOC-AE-14003142 Page 19 of 155 Permit Number: WQ0001908000 Applicant; STP Nuclear Operating Company Certification:
I, Michael P. Murray                                           Manager, Regulatory Affairs Typed or printed name                                                   Title certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware there are significant penalties for submitting false information, including thepossibility of fine and imprisonment for knowing violations.
I further certify that I am authorized under 30 Texas Administrative Code &sect;305.44 to sign and submit this document, and can provide documentation in proof'of such authorization upon request.
Signature:                                                               Date:                 2    /*
                                                                                                  ,*2 (Use l"e       k)
Subscribed and Sworn to before me by the said- M*                c\ c\  &#xfd;A     \ L*t(Ctu on this                       dayof                                             o2
                                                                              ,20 My commission expires on the                   LAh-         day of             I             ,2o   )WL
                    \~                                                                 [SEAL]
Notary Public County, Texas tf co-permittees are necessary, each entity must submit an original, separatesignaturepage.
TCEQ-1041 i (9/1/2010) Industrial Wastewater Permit Application -Administrative Report             Page 14 of 18
 
Attachment NOC-AE-14003142 Page 20 of 155 Industrial Administrative Report 1.1
 
Attachment NOC-AE-14003142 Page 21 of 155 INDUSTRIAL ADMINISTRATIVE REPORT 1.1 Thefollowing is requir'edfor new and amendment applications.
See Attachment C
: a. Indicate by a check mark that the landowners map or drawing, with scale, includes the following, as applicable.
[A The applicant's property boundaries
[A The applicant's property boundaries
[El The facility site boundaries within the applicant's property boundaries FD The distance the buffer zone falls into adjacent properties and the property boundaries of the landowners located within the buffer zone[E The property boundaries of all landowners surrounding the applicant's property[ The point(s) of discharge and highlighted discharge route clearly shown for one mile downstream
[El The facility site boundaries within the applicant's property boundaries FD The distance the buffer zone falls into adjacent properties and the property boundaries of the landowners located within the buffer zone
* The property boundaries of the landowners located on both sides of the discharge route for one full stream mile downstream of the point of discharge[E The property boundaries of the landowners along the watercourse for a one-half mile radius from the point of discharge if the point of discharge is into a lake, bay estuary, or affected by tides F The boundaries of the effluent disposal site (for example, irrigation area or subsurface drainfield site), all evaporation/holding ponds within the applicant's property El The property boundaries of all landowners surrounding the applicant's property boundaries where the effluent disposal site is located El The boundaries of the sludge land application site (for land application of sewage sludge for beneficial use) and the property boundaries of landowners surrounding the applicant's property boundaries where the sewage sludge land application site is located E The property boundaries of landowners within one-half mile in all directions from the applicant's property boundaries where the sewage sludge disposal site (for example, sludge surface disposal site or sludge monofill) is located b. Indicate by a check mark in which format the landowners list is submitted:
[E The property boundaries of all landowners surrounding the applicant's property
[N Read/Writeable CD or Disk [-l 4 sets of labels c. Indicate by a check mark that a separate list with the landowners' names and mailing address cross-referenced to the landowners map has been provided.  
[ The point(s) of discharge and highlighted discharge route clearly shown for one mile downstream
[E d. Provide the source of the landowners' names and mailing addresses.
* The property boundaries of the landowners located on both sides of the discharge route for one full stream mile downstream of the point of discharge
Matagorda County Appraisal District, 2014 Parcel Boundary & 2013 Tax Roll TCEQ-1 0411 (9/1/2010)
[E The property boundaries of the landowners along the watercourse for a one-half mile radius from the point of discharge if the point of discharge is into a lake, bay estuary, or affected by tides F The boundaries of the effluent disposal site (for example, irrigation area or subsurface drainfield site), all evaporation/holding ponds within the applicant's property El The property boundaries of all landowners surrounding the applicant's property boundaries where the effluent disposal site is located El The boundaries of the sludge land application site (for land application of sewage sludge for beneficial use) and the property boundaries of landowners surrounding the applicant's property boundaries where the sewage sludge land application site is located E The property boundaries of landowners within one-half mile in all directions from the applicant's property boundaries where the sewage sludge disposal site (for example, sludge surface disposal site or sludge monofill) is located
Industrial Wastewater Permit Application  
: b. Indicate by a check mark in which format the landowners list is submitted:
-Administrative Report Page 15 of 18 Attachment NOC-AE-14003142 Page 22 of 155 c. As required by Texas Water Code &sect;5.115, is any permanent school fund land affected by this application?  
[N Read/Writeable CD or Disk                     [-l 4 sets of labels
[] Yes [] No If yes, provide the location and foreseeable impacts and effects this application has on the land(s)..... ..~ ~ ~ ~ ~~ ~ ~~~ ~~~...... ......:  
: c. Indicate by a check mark that a separate list with the landowners' names and mailing address cross-referenced to the landowners map has been provided. [E
.i.?! `Provide original ground level photographs.
: d. Provide the source of the landowners' names and mailing addresses.
Indicate by checking that the following information is provided.
Matagorda County Appraisal District, 2014 Parcel Boundary & 2013 Tax Roll TCEQ-1 0411 (9/1/2010) Industrial Wastewater Permit Application - Administrative Report         Page 15 of 18
See Attachment D El At least one original photograph of the new or expanded treatment unit location[ At least two photographs of the existing/proposed point of discharge and as much area downstream (photo i) and upstream (photo 2) as can be captured.F- If the discharge is to an open water body (e.g., lake, bay), the point of discharge should be in the right or left edge of each photograph showing the open water and with as much area on each respective side of the discharge as can be captured, El At least one photograph of the existing/proposed effluent disposal site AJ A plot plan or map showing the location and direction of each photograph TCEQ-1 0411 (9/1/2010)
 
Industrial Wastewater Permit Application  
Attachment NOC-AE-14003142 Page 22 of 155
-Administrative Report Page 16 of IS Attachment NOC-AE-14003142 Page 23 of 155 Supplemental Permit Information Form Attachment NOC-AE-14003142 Page 24 of 155 TEXAS COMMISSION ON ENVIRONMENTAL QUALITY SUPPLEMENTAL PERMIT INFORMATION FORM (SPIF)FOR AGENCIES REVIEWING INDUSTRIAL TPDES WASTEWATER PERMIT APPLICATIONS T-CJQ VSE ONLY: -APPlieat~i6n~type., 'iiRenewal Majot Amnendment Minor Amendrtient -New c&#xfd;Otnty:_
: c. As required by Texas Water Code &sect;5.115, is any permanent school fund land affected by this application? [] Yes [] No If yes, provide the location and foreseeable impacts and effects this application has on the land(s).
Segment Number -_Admin Com~plete Date:_______
        . . ...   .~                       .i`*
Agency Receiving SPIV:___Texas H-istorical commfns~ion-US Fish and WAildlife This form applies to TPDES permit applications only. (Instructions, Page 34)The SPIF must be completed as a separate document.
                                              ......      ~~ ~       ~~       ~ ~~~ ~~~......
The TCEQ will mail a copy of the SPIF to each agency as required by the TCEQ agreement with EPA. If any of the items are not completely addressed and/or further information is needed, you will be contacted to provide the information before the permit Is issued. Each item must be completely addressed.
: .`.:-.:*y  . i.?! i;* *% `
Do not refer to a response of any item in the permit application form. Each attachment must be provided with this form separately from the administrative report of the application.
Provide original ground level photographs. Indicate by checking that the following information is provided. See Attachment D El   At least one original photograph of the new or expanded treatment unit location
The application will not be declared administratively complete without this form being completed in its entirety including all attachments.
[   At least two photographs of the existing/proposed point of discharge and as much area downstream (photo i) and upstream (photo 2) as can be captured.
F- If the discharge is to an open water body (e.g., lake, bay), the point of discharge should be in the right or left edge of each photograph showing the open water and with as much area on each respective side of the discharge as can be captured, El   At least one photograph of the existing/proposed effluent disposal site AJ A plot plan or map showing the location and direction of each photograph TCEQ-1 0411 (9/1/2010) Industrial Wastewater Permit Application - Administrative Report                 Page 16 of IS
 
Attachment NOC-AE-14003142 Page 23 of 155 Supplemental Permit Information Form
 
Attachment NOC-AE-14003142 Page 24 of 155 TEXAS COMMISSION ON ENVIRONMENTAL QUALITY SUPPLEMENTAL PERMIT INFORMATION FORM (SPIF)
FOR AGENCIES REVIEWING INDUSTRIAL TPDES WASTEWATER PERMIT APPLICATIONS T-CJQ VSE ONLY:                   -
APPlieat~i6n~type.,       'iiRenewal     Majot Amnendment           Minor Amendrtient       -New c&#xfd;Otnty:_                           Segment Number           -_Admin         Com~plete Date:_______
Agency Receiving SPIV:
___Texas   H-istorical commfns~ion-                             US Fish and WAildlife This form applies to TPDES permit applications only. (Instructions, Page 34)
The SPIF must be completed as a separate document. The TCEQ will mail a copy of the SPIF to each agency as required by the TCEQ agreement with EPA. If any of the items are not completely addressed and/or further information is needed, you will be contacted to provide the information before the permit Is issued. Each item must be completely addressed.
Do not refer to a response of any item in the permit application form. Each attachment must be provided with this form separately from the administrative report of the application. The application will not be declared administratively complete without this form being completed in its entirety including all attachments.
The following applies to all applications:
The following applies to all applications:
: 1. Permlttee:
: 1. Permlttee: STP Nuclear Operating Company
STP Nuclear Operating Company 2. Permit No. WQoo 0 1 9 0 8 0 0 0 (EPA ID No.) TX 0 0 6 4 9 4 7 3. Address of the project (location description that includes street/highway, ity/vicinity, & county)12090 Farm-to-Market Road 521, Wadsworth, Texas 77483 4. Provide the name, address, phone and fax number of an individual that can be contacted to answer specific questions about the property.Name: John Hoffman Company: STP Nuclear Operating Company Phone number: (361) 972-4507 Fax number: Street No.: Street name: Street type: P.O. Box, 289 City: Wadsworth State: TX ZIP code: 7 7 4 8 3 Email: jphoffman@stpegs.com TCEQ-10411 (9/1/2010)
: 2. Permit No. WQoo 0 1 9 0 8 0 0 0                           (EPA ID No.) TX 0 0 6 4 9 4 7
Industrial Wastewater Permit Application  
: 3. Address of the project (location description that includes street/highway, ity/vicinity, & county) 12090 Farm-to-Market Road 521, Wadsworth, Texas 77483
-Administrative Report Page 17 of 18 Attachment NOC-AE-14003142 Page 25 of 155 5. List the county in which the facility is located:.Matagorda
: 4. Provide the name, address, phone and fax number of an individual that can be contacted to answer specific questions about the property.
: 6. If the property is publicly owned and the owner is different than the permittee/applicant, please list the owner of the property.N/A 7. Provide a description of the effluent discharge route. The discharge route must follow the flow of effluent from the point of discharge to the nearest major watercourse (from the point of discharge to a classified segment as defined in 30 TAC Chapter 307). If known, please identify the Segment Number.L 'a Ot directh, lo Co0oraao Rlver t12al; via M2e tome Plant.area Drainage Dto, then tO'Coorado Tidal; via 002 to an unnamed oitch, loe n 1 an unnamed trbutar of West Branh of Colorado River, then to West Branch of Colorado River, then to Mategorda Bay/Powderhomr Lake: via 004 to en unnamed ditch then to Colorado RiverI Tidal In Segment No. 1401 of Colorado River Baon; via 005 to East Fork Little RobbinaSlough, then to Robbins Slough, then to Robbins Lake, than to Robbins Slough, I then to Crab Lake, then to Crab Bayou, then to Gulf Intercoastal Waterway, then to Metagorda Bay/Powderhorn Lake; and via 006 to Little Robbing Slough, then to an-'M O _ H.. .. .... ....... ...... .... .. ...to m- .. ..i '. W ks.
Name: John Hoffman                                     Company: STP Nuclear Operating Company Phone number: (361) 972-4507                             Fax number:
* to In ' .'.. ...I .' , ...ft e Intercoastal Waterway, .hen to Matagorda Bey/Powderhom Lka In Segment No. 2451 of theBays and vatuarles 8. Please provide a separate 7.5 minute USGS quadrangle map with the project boundaries plotted and a general location map showing the project area. Please highlight the discharge route from the point of discharge for a distance of one mile downstream. (This map is required in addition to the map in the administrative report). See Attachment E 9. Provide original photographs of any structures 50 years or older on the property.io. Does your project involve any of the following?
Street No.:                 Street name:                                           Street type:
Check all that apply.n] a. Proposed access roads, utility lines, construction easements D1 b. Visual effects that could damage or detract from a historic property's integrity H c. Vibration effects during construction or as a result of project design d. Additional phases of development that are planned for the future e. Sealing caves, fractures, sinkholes, other karst features f. Disturbance of vegetation or wetlands ii. List proposed construction impact (surface acres to be impacted, depth of excavation, sealing of caves, or other karst features).
P.O. Box, 289               City: Wadsworth                     State:   TX       ZIP code: 7 7 4 8 3 Email: jphoffman@stpegs.com TCEQ-10411 (9/1/2010) Industrial Wastewater Permit Application - Administrative Report             Page 17 of 18
: 12. Describe existing disturbances, vegetation and land use.THIE FOLLO;W.-NG ITEMS-` POPLYO L QAPI'IN O E TPES PEIIMTTS&#xfd; AD MAJOQ"-R ;AMENDMENTS TO PDE 1MfS 13. List construction dates of all buildings and structures on the property..NN/A 14. Provide a brief history of the property, and name of the architect/builder, if known.TCEQ-1 0411 (9/1/2010)
 
Industrial Wastewater Permit Application  
Attachment NOC-AE-14003142 Page 25 of 155
-Administrative Report Page 18 of 18 Attachment NOC-AE-14003142 Page 26 of 155 Industrial Technical Report 1.0 (
: 5. List the county in which the facility is located:.Matagorda
Attachment NOC-AE-14003142 Page 27 of 155 TECHNICAL REPORT 1.o INDUSTRIAL THE FOLLOWING IS REQUIRED FOR ALL APPLICATIONS RENEWAL, NEW, AND AMENDMENT a. Describe the type of activity and general nature of your business.South Texas (STP) Electric Generating Station is a nuclear fueled, steam-electric generating facility.
: 6. If the property is publicly owned and the owner is different than the permittee/applicant, please list the owner of the property.
Electricity is generated from steam driven turbines.b. SIC Code(s) 4911 , , NAICS Code(s) 221113 , , c. Describe the wastewater generating processes.
N/A
See Attachment F d. Provide a list of raw materials, major intermediates, and products handled at your facility.Raw Materials Intermediate Products Final Products Nuclear Fuel (7440-61-1)
: 7. Provide a description of the effluent discharge route. The discharge route must follow the flow of effluent from the point of discharge to the nearest major watercourse (from the point of discharge to a classified segment as defined in 30 L
Steam Electricity TCEQ-10055 (05/15/2012)
TAC Chapter 307). If known, please identify the Segment Number.
Industrial Wastewater Permit Application Technical Report Page I of 66 Attachment NOC-AE-14003142 Page 28 of 155 e. Indicate by a check mark that an attached facility map with the following information was provided with the application:
          'aOt directh, lo Co0oraao Rlver t12al; via M2etome Plant.areaDrainage Dto, then tO'Coorado *liverTidal; via 002 to an unnamed oitch, loen 1 an unnamed trbutar of West Branh of Colorado River, then to West Branch of Colorado River, then to Mategorda Bay/Powderhomr Lake: via 004 to en unnamed ditch then to Colorado RiverI Tidal InSegment No. 1401 of Colorado River Baon; via 005 to East Fork Little RobbinaSlough, then to Robbins Slough, then to Robbins Lake, than to Robbins Slough, Ithen to Crab Lake, then to Crab Bayou, then to Gulf Intercoastal Waterway, then to Metagorda Bay/Powderhorn Lake; and via 006 to LittleRobbing Slough, then to an
[1 Production areas, maintenance areas, materials handling areas, and waste disposal areas.[71 The location of each unit of the wastewater treatment plant including the location of wastewater collection sumps and impoundments.
          -   O_'M H....     .    ... .                               . ks... .. to
Attachment  
                                                  . . .... to m-...... . W          . . .                   .. . .i In      '.     . *. . I
#: G f. Is this a new permit application for an existing facility?If yes, provide background discussion below.ED Yes IZ No N/A g. Is the treatment facility/disposal site located above the 1oo-year frequency flood level?fZYes F No List source(s) used to determine 1oo-year frequency flood plain: FIRM 485489037C, March 18, 1985 If no, provide the elevation of the 1o0-year frequency flood plain and describe what protective measures are in use or planned to be used to prevent flooding of the treatment facility/disposal area.N/A h. For new or amendment permit applications, will there be discharge of fill material into a water in the state for construction of the proposed outfall structure?
                                                                                                                                  .'.. .' e '            , . .     ft.
El Yes W1 No If no, proceed to Item No. 2. If yes, has the a plicant applied for a U.S. Corps of Engineers 404 Dredge and Fill permit? [_Yes LI No If yes, provide the permit number: If no, provide the approximate date you anticipate submitting your application to the Corps.TCEQ-10055 (05/15/2012)
Intercoastal Waterway, .hen to Matagorda Bey/Powderhom Lka In Segment No. 2451 of theBays and vatuarles
Industrial Wastewater Permit Application Technical Report Page 2 of 66 Attachment NOC-AE-14003142 Page 29 of 155 a. List any physical, chemical, an/or biological treatment process that y ou use f or the treatm ent of wastewater at your facility.
: 8. Please provide a separate 7.5 minute USGS quadrangle map with the project boundaries plotted and a general location map showing the project area. Please highlight the discharge route from the point of discharge for a distance of one mile downstream. (This map is required in addition to the map in the administrative report). See Attachment E
Include a description of each treatment process starting with initial treatment and finishing with the discharge point.See Attachment K b. [] Indicate by a check mark t hat an attached flow schematic with a water balance was provided with the applications showing each treatment unit and all sources of wastewater flow into the treatment plant and to each outfall/point of disposal.Attachment  
: 9. Provide original photographs of any structures 50 years or older on the property.
#: H Do you use or plan to use any wastewater lagoons, ponds, or impoundments 71 YesR No If yes, complete item 3(a) for existing impoundments and items 3(a)-3(t) for new or proposed impoundments.
io. Does your project involve any of the following? Check all that apply.
If no, proceed to Item No. 4.a. Provide the following information in the table provided: Dcsignation:
n] a. Proposed access roads, utility lines, construction easements D1 b. Visual effects that could damage or detract from a historic property's integrity H       c. Vibration effects during construction or as a result of project design
Indicate t he appropriate u se designation for each p ond [ Treatment (T), Disposal (D), Containment (C), or Evaporation (E)]Discharge Point: If a discharge occurs from the Impoundments, designate the outfall associated with the impoundment.
: d. Additional phases of development that are planned for the future
Liner I nformation:
: e. Sealing caves, fractures, sinkholes, other karst features
If the impoundments are lined to comply with specifications outlined for t) a c ompacted clay liner (C), 2) an in-situ clay l iner (I), or 3) a synthetic/plastic/rubber liner (S), indicate the liner type with the appropriate letter designation (see instructions for further detail on liner specifications).
: f. Disturbance of vegetation or wetlands ii. List proposed construction impact (surface acres to be impacted, depth of excavation, sealing of caves, or other karst features).
If not, provide a reference to the attachment that provides a description of the alternate liner and any additional technical information necessary for an evaluation.
: 12. Describe existing disturbances, vegetation and land use.
Dimensions:
THIE FOLLO;W.-NG ITEMS-` POPLYO L QAPI'IN                                                                                                 O         E TPES PEIIMTTS&#xfd; AD MAJOQ"-R;AMENDMENTS TO PDE                                                                                         1MfS
Provide t he dimensions(s), f reeboard, surface area, an d storage volume capacity of the impoundments.
: 13. List construction dates of all buildings and structures on the property.
For impoundments with irregular shapes, submit surface area (instead of length an d width), the average depth, an d the maximum depth b elow natural ground level.TCEQ-1 0055 (0511612012)
      .NN/A
Industrial Wastewater Permit Application Technical Report Page 3 of 66 Attachment NOC-AE-14003142 Page 30 of 155 Pond# 1 Pond# 2 Pond J Pond# 4 Pond# 6 Designation (T) (D) (C) or (E) T T T T Discharge Point j.Outfall Number 501 501 101 001 none Liner Information Liner Type (C) (I) or (S) reinforce concrete reinforce concrete reinforce concrete soil and concrete none Alt. Liner Attachment Reference n/a n/a n/a n/a n/a Dimensions Length (feet) 100 ft 25 ft 136 ft .nia ft 150,ft Width (feet) 5o0 ft 25 ft 42 ft n/a ft 70 ft Depth from Water Surface 17.5 ft 13.3 ft 10 ft 20 ft 4 ft Depth from Nat. Ground Level .avg 0 max o avg oymax o2avg omax __o avg. o max 0 avg -2Lmax Freeboard (feet) '0 ft >2 ft >2 ft 2, ft '2 ft Surface Area (acres) o.io acres O.Ol acres 0.13 acres 7,000 acres 024 acres Storage Capacity (gallons) 1,000.000 gal 50,000 gal 600,000 gal " 6.6e0 gal 31.4,160 gal Pond # P_ ond# Pond# Pond## Pond#-Designation (T) (D) (C) or (E) C Discharge Point Outfall Number None Liner Informati-on-Liner Type (C) (I) or (S) soil and concrete Alt. Liner Attachment Reference n/a Dimensions Length (feet) .ft Width (feet) .1,0oo ft .ft _ .ft ft ft Depth from Water Surface 8 ft ft ft _ ft ft Depth from Nat. Ground Level (avg/max) (feet) 0 .0 I .I .Freeboard (feet) '2 ft ft _ _ft _ ft ft Surface Area (acres) 47 acres acres _ acres 'acres .acres Storage Capacity (gallons) 1.3ea gal gal _ gal _ .gal _ gal TCEQ-10055 (05/15/2012)
: 14. Provide a brief history of the property, and name of the architect/builder, if known.
Industrial Wastewater Permit Application Technical Report Page 4 of 66 Attachment NOC-AE-14003142 Page 31 of 155 THE FO LLOWING I TEMS A RE R EQUIRED 0 NLY FO R N EW 0 R PR OPOSED IMPOUNDMENTS.
TCEQ-1 0411 (9/1/2010) Industrial Wastewater Permit Application - Administrative Report                                                                 Page 18 of 18
 
Attachment NOC-AE-14003142 Page 26 of 155 Industrial Technical Report 1.0
(
 
Attachment NOC-AE-14003142 Page 27 of 155 TECHNICAL REPORT 1.o INDUSTRIAL THE FOLLOWING IS REQUIRED FOR ALL APPLICATIONS RENEWAL, NEW, AND AMENDMENT
: a. Describe the type of activity and general nature of your business.
South Texas (STP) Electric Generating Station is a nuclear fueled, steam-electric generating facility. Electricity is generated from steam driven turbines.
: b. SIC Code(s)           4911                               ,                 ,
NAICS Code(s)         221113                             ,                 ,
: c. Describe the wastewater generating processes.
See Attachment F
: d. Provide a list of raw materials, major intermediates, and products handled at your facility.
Raw Materials                         Intermediate Products               Final Products Nuclear Fuel (7440-61-1)                                 Steam                     Electricity TCEQ-10055 (05/15/2012) Industrial Wastewater Permit Application Technical Report             Page I of 66
 
Attachment NOC-AE-14003142 Page 28 of 155
: e. Indicate by a check mark that an attached facility map with the following information was provided with the application:
[1 Production areas, maintenance areas, materials handling areas, and waste disposal areas.
[71 The location of each unit of the wastewater treatment plant including the location of wastewater collection sumps and impoundments.
Attachment #:                 G
: f. Is this a new permit application for an existing facility?                       ED Yes IZ No If yes, provide background discussion below.
N/A
: g. Is the treatment facility/disposal site located above the 1oo-year frequency flood level?
fZYes       F No List source(s) used to determine 1oo-year frequency flood plain:
FIRM 485489037C, March 18, 1985 If no, provide the elevation of the 1o0-year frequency flood plain and describe what protective measures are in use or planned to be used to prevent flooding of the treatment facility/disposal area.
N/A
: h. For new or amendment permit applications, will there be discharge of fill material into a water in the state for construction of the proposed outfall structure? El Yes W1 No If no, proceed to Item No. 2. If yes, has the a plicant applied for a U.S. Corps of Engineers 404 Dredge and Fill permit?                         [_Yes         LI No If yes, provide the permit number:
If no, provide the approximate date you anticipate submitting your application to the Corps.
TCEQ-10055 (05/15/2012) Industrial Wastewater Permit Application Technical Report               Page 2 of 66
 
Attachment NOC-AE-14003142 Page 29 of 155
: a. List any physical, chemical, an/or biological treatment process that y ou use f or the treatm ent of wastewater at your facility. Include a description of each treatment process starting with initial treatment and finishing with the discharge point.
See Attachment K
: b. [] Indicate by a check mark t hat an attached flow schematic with a water balance was provided with the applications showing each treatment unit and all sources of wastewater flow into the treatment plant and to each outfall/point of disposal.
Attachment #:                       H Do you use or plan to use any wastewater lagoons, ponds, or impoundments 71 YesR No If yes, complete item 3(a) for existing impoundments and items 3(a)-3(t) for new or proposed impoundments. If no, proceed to Item No. 4.
: a. Provide the following information in the table provided:
Dcsignation: Indicate t he appropriate u se designation for each p ond [ Treatment (T),
Disposal (D), Containment (C), or Evaporation (E)]
Discharge Point: If a discharge occurs from the Impoundments, designate the outfall associated with the impoundment.
Liner I nformation: If the impoundments are lined to comply with specifications outlined for t) a c ompacted clay liner (C), 2) an in-situ clay l iner (I), or 3) a synthetic/plastic/rubber liner (S), indicate the liner type with the appropriate letter designation (see instructions for further detail on liner specifications). If not, provide a reference to the attachment that provides a description of the alternate liner and any additional technical information necessary for an evaluation.
Dimensions: Provide t he dimensions(s), f reeboard, surface area, an d storage volume capacity of the impoundments. For impoundments with irregular shapes, submit surface area (instead of length an d width), the average depth, an d the maximum depth b elow natural ground level.
TCEQ-1 0055 (0511612012) Industrial Wastewater Permit Application Technical Report   Page 3 of 66
 
Attachment NOC-AE-14003142 Page 30 of 155 Pond#           1   Pond#         2     Pond           J Pond#           4     Pond#         6 Designation (T) (D) (C) or (E)                                 T                 T                   T                 T Discharge Point                                                                                                       j.
Outfall Number                                   501               501                 101               001                   none Liner Information Liner Type (C) (I) or (S)             reinforce concrete reinforce concrete reinforce concrete soil and concrete                 none Alt. Liner Attachment Reference                   n/a               n/a                 n/a               n/a                   n/a Dimensions Length (feet)                             100     ft         25     ft           136   ft     .nia       ft           150,ft Width (feet)                                 5o0   ft           25     ft             42   ft         n/a ft                 70     ft Depth from Water Surface                   17.5   ft         13.3   ft             10   ft         20     ft             4     ft Depth from Nat. Ground Level           .avg         0 max o avg oymax           o2avg omax     __o avg. o max           0 avg -2Lmax Freeboard (feet)                           '0   ft           >2     ft             >2   ft         2,       ft           '2     ft Surface Area (acres)                     o.io   acres       O.Olacres            0.13   acres     7,000acres            024     acres Storage Capacity (gallons)             1,000.000   gal     50,000 gal           600,000 gal "     6.6e0 gal             31.4,160   gal Pond #                 P_
ond#               Pond#             Pond##                 Pond#
-Designation                         !***"
(T) (D) (C) or (E)                                 C Discharge Point Outfall Number                                   None Liner Informati-on-Liner Type (C) (I) or (S)           soil and concrete Alt. Liner Attachment Reference                   n/a Dimensions Length (feet)                             .ft Width (feet)     .                       1,0oo ft                   .ft         _       .ft               ft                     ft Depth from Water Surface                   8     ft                 ft                   ft     _         ft                     ft Depth from Nat. Ground Level (avg/max) (feet)                               0 . 0                 I                   .I .
Freeboard (feet)                           '2     ft                 ft       _       _ft           _     ft                   ft Surface Area (acres)                     47     acres             acres     _         acres           'acres             .acres Storage Capacity (gallons)               1.3ea     gal                 gal     _           gal   __        . gal                   gal TCEQ-10055 (05/15/2012) Industrial Wastewater Permit Application Technical Report                                 Page 4 of 66
 
Attachment NOC-AE-14003142 Page 31 of 155 THE FO LLOWING I TEMS A RE R EQUIRED 0 NLY FO R N EW 0 R PR OPOSED IMPOUNDMENTS.
: b. Indicate by a check mark if any of the following data was provided with the application:
: b. Indicate by a check mark if any of the following data was provided with the application:
Li Synthetic/plastic/rubber liner data LI In-situ clay liner data Not Applicable Attachment  
Li Synthetic/plastic/rubber liner data LIIn-situ clay liner data                               Not Applicable Attachment #:_
#:_c. Are there any leak detection systems or ground water monitoring wells in place or planned? Li Yes ni No Not Applicable Li If yes, indicate by a check mark that a separate attachment was provided with the leak detection system information for each pond and/or gr ound water monitoring well data.Attachment  
: c. Are there any leak detection systems or ground water monitoring wells in place or planned?         Li Yes ni No                   Not Applicable Li If yes, indicate by a check mark that a separate attachment was provided with the leak detection system information for each pond and/or gr ound water monitoring well data.
#: d. Is t he b ottom of the p ond a bove t he s easonal high water t able in t he shallowest water bearing zone?Li Yes Li No Not Applicable Li If no, indicate by a check m ark that additional information was provided describing the depth of the seasonal high water table in the shallowest water bearing zone in relation to the depth of the bottom of the new or proposed impoundment and how this may or may not impact groundwater.
Attachment #:
: e. Indicate by a check mark that the following information was provided:
: d. Is t he b ottom of the p ond a bove t he s easonal high water t able in t he shallowest water bearing zone?
Not Applicable L] A USGS quadrangle map or a color copy of original quality and scale which accurately locates and identifies water supply wells and/or monitor wells within 1/2 mile radius of the impoundments.
Li Yes Li No                   Not Applicable Li   If no, indicate by a check m ark that additional information was provided describing the depth of the seasonal high water table in the shallowest water bearing zone in relation to the depth of the bottom of the new or proposed impoundment and how this may or may not impact groundwater.
Li Copies of State Water Well Reports (driller's logs, completion data), and data on depths to g round water for water supply w ells in cluding a d escription o f how t he d epths t o ground water were obtained.For TLAP permit applications:
: e. Indicate by a check mark that the following information was provided:                             Not Applicable L] A USGS quadrangle map or a color copy of original quality and scale which accurately locates and identifies water supply wells and/or monitor wells within                         1/2 mile radius of the impoundments.
Not Applicable Li Indicate by a check mark t hat t he new or proposed impoundment(s) and the land application disposal area are located in the same general area and the information for this item is provided in Worksheet 3.0 (item 8).Not Applicable
Li Copies of State Water Well Reports (driller's logs, completion data),                         and data on depths to g round water for water supply w ells in cluding a d escription o f how t he d epths t o ground water were obtained.
: f. i- Indicate by a check mark id any data was provided with the application pertaining to the ground water, soils, geology, etc. used to assess the potential for migration of wastes from the impoundments and/or the potential for contamination of ground water or surface water.Complete the following tables to describe the location and wastewater discharge or disposal operations for each outfall for discharge operations and for each point of disposal for TLAP operations.
For TLAP permit applications: Not Applicable Li Indicate by a check mark t hat t he new or proposed impoundment(s) and the land application disposal area are located in the same general area and the information for this item is provided in Worksheet 3.0 (item 8).
For TLAP permit applications:
Not Applicable
Indicate the disposal method and each individual lirigation area (i), evaporation pond ( E), or subsurface drainage system (S) by providing the appropriate letter designation for the disposal method followed by a numerical designation for each disposal area (e.g. evaporation pond, application area) in the space provided for "Outfall" designation e.g. "E'" for ev oration pond 1 "12" for irrigation area No. 2, etc.).TCEO-. 0055 (05A/517012)
: f. i- Indicate by a check mark id any data was provided with the application pertaining to the ground water, soils, geology, etc. used to assess the potential for migration of wastes from the impoundments and/or the potential for contamination of ground water or surface water.
Industrial Wasttegater Permit Application Technical Report Page of 66 Attachment NOC-AE-14003142 Page 32 of 155 OUTFALL: 001-Latitude .' -Longitude*-
Complete the following tables to describe the location and wastewater discharge or disposal operations for each outfall for discharge operations and for each point of disposal for TLAP operations.
Location Des.riptloh 8 44 96 00 .02 At a point in the blowdown line prior to entering the(MGD) Pirposed Fl",op(MD), Colorado River Dly Avg Dly MaVix. Dly Avg, -fy 3 3/4 1schar ge; I.tration 144 200 144 200 ** (hrs./day)  
For TLAP permit applications: Indicate the disposal method and each individual lirigation area (i), evaporation pond ( E), or subsurface drainage system (S) by providing the appropriate letter designation for the disposal method followed by a numerical designation for each disposal area (e.g. evaporation pond, application area) in the space provided for "Outfall" designation e.g.       "E'" for ev       oration pond 1           "12"   for irrigation area No. 2, etc.).
** (days/mo.)  
TCEO-. 0055 (05A/517012) Industrial Wasttegater Permit Application Technical Report                       Page of 66
**_(mo./year)
 
X PumpedGravlty Measurement Device: Estimate X Intermittent
Attachment NOC-AE-14003142 Page 32 of 155 OUTFALL:             001
_ Seasonal Continuous
  -     Latitude         . '       -Longitude*-                                             Location Des.riptloh 8 44                     96           00       .02       At a point in the blowdown line prior to entering the
,:.: *:..h..... ting W4te0trAfis:-
:Pirmitt*d*iow (MGD)             Pirposed Fl",op(MD),             Colorado River Dly Avg       Dly MaVix.     Dly Avg,         -fy         3/4                               31schar ge;I.tration 144             200             144               200             **       (hrs./day) **           (days/mo.) **_(mo./year)
6 -Volme (MOD) Oz/f to'ta low Recirculated cooling water n/a** n/a**Cooling reservoir blowdown Previously monitored effluent Stormwater Makeup water from the Colorado River Uncontaminated groundwater
X PumpedGravlty             Measurement Device: Estimate                         X Intermittent _ Seasonal                               Continuous ting W4te0trAfis:-
*At spillway.
      ..h.....                                                                       -Volme 6         (MOD)                   Oz/f to'ta low Recirculated cooling water                                               n/a**                                     n/a**
At blowdown at the river: 28' 44' 46" N, 96' 00' 02" W"*There has been no discharge from the outfall since March 4, 1997 OUTFALL: 002 La- tte Ul.et :. Location Doscription  
Cooling reservoir blowdown Previously monitored effluent Stormwater Makeup water from the Colorado River Uncontaminated groundwater
, 468I 29 95 II 59 II 53 Prior to entering the plant drainage ditch Pemte PoG) Proposed, IIW o.(M.Gb)Pi vg Dy Max IJyAg. -D~Ma se t harge burat onj n/a n/a n/a n/a n/a (hrs./day)  
*At spillway. At blowdown at the river: 28' 44' 46" N,96' 00' 02" W
!la (days/mo.)  
"*Therehas been no discharge from the outfall since March 4, 1997 OUTFALL: 002 La-tteUl.et                                               :.                     Location Doscription                       ,
/a (nmo./year)
468I     29         95   II     59 II     53     Prior to entering the plant drainage ditch PemtePoG)               Proposed, IIW   o.(M.Gb) vg      Pi Max Dy             IJyAg.                 -D~Ma                                 t se harge burat onj n/a           n/a             n/a               n/a             n/a     (hrs./day) !la         (days/mo.)             /a             (nmo./year)
Pumped _L Gravity Measurement Device: estimate X Intermittent -Seasonal
Pumped _L Gravity         Measurement Device: estimate                         X Intermittent       -Seasonal _                       Continuous Reservoir relief well effluent (wells 1-125)                               Intermittent Demlneralized water from instrumentation                                   Intermittent t                             *11*
_ Continuous Reservoir relief well effluent (wells 1-125) Intermittent Demlneralized water from instrumentation Intermittent
p                           *
.., ..-t *11*p *.11.TCEQ-1 0055 (05/15/2012)
                                                                                                              .11.
Industrial Wastewater Permit Application Technical Report Page 6 of 66 Attachment NOC-AE-14003142 Page 33 of 155 OUTFALL: 003 Latituide'.
TCEQ-1 0055 (05/15/2012) Industrial Wastewater Permit Application Technical Report                                           Page 6 of 66
Longf1tude Lorato ecrption 28 44 49 96 700 J40 At the discharge of flowing relief wells prior to mixing 1Permiitted FloW.(MGi)
 
Wl- ooe P (MGO with the West Branch of Colorado River Ply Ag pDly Max. ...ly"Av .., D1miD Max 0 , .-..bscharge a i ratlon d n/a n/a n/a n/a (hrs./day) (days/mo.)  
Attachment NOC-AE-14003142 Page 33 of 155 OUTFALL:               003 Latituide'.                   Longf1tude                                         Lorato       ecrption 28         44         49   700  96     J40                   At the discharge of flowing relief wells prior to mixing 1Permiitted FloW.(MGi)               ooe P Wl-       (MGO       with the West Branch of Colorado River Ply Ag         pDly Max.   . .. ly"Av     ..,     D1miD Max             ,         .     -.. bscharge 0 a d    i ratlon n/a             n/a             n/a               n/a                   (hrs./day)               (days/mo.)         ..   (mo.Iyear)
.. (mo.Iyear)
Pumped         Gravity   Measurement Device: Estmlate                           X   Intermittent   -Seasonal             Continuous Cnrbuting W&#xfd;~testrqamn                                                     .       Vo         GeMD)         *Of     Total     Co.
Pumped Gravity Measurement Device: Estmlate X Intermittent -Seasonal Continuous Cnrbuting W&#xfd;~testrqamn  
Reservoir Relief Well effluent (wells 138-195)                                   Intermittent                         100 OUTFALL: 004 Latitudle,                     Longitude                                           Location &#xfd;Deicri ption 28         44 ThiT IIEEgate Permnitte".d :FloW"(kO) 57       96             01 Prposed Flow (MGD)-
.Vo GeMD) *Of Total Co.Reservoir Relief Well effluent (wells 138-195) Intermittent 100 OUTFALL: 004 Latitudle, Longitude Location &#xfd;Deicri ption 28 44 57 96 01 03 Ata point in the MCR Spillway Channel after commingling of spillway ThiT IIEEgate leakage and relief well water, and prior to mixing with other waters P e rmnitte".d
03    Ata point inthe MCR Spillway Channel after commingling of spillway leakage and relief well water, and prior to mixing with other waters i~li~g.DbiMa               yDAvg, -     .~   i~ak                               Kqshag         urat~ion       j n/a             n/a             n/a               n/a     ,     _     _(hrs,/day) .             (days/mo.)           .(mo./year)
:FloW" (kO) Prposed Flow (MGD)-i~li~g. DbiMa yDAvg, -.~ i~ak Kqshag urat~ion j n/a n/a n/a n/a , _ _(hrs,/day)  
Pumped X       Gravity   Measurement Device: Estimate                           Xintermittent     -Seasonal     __Continuous Rebutlng       Relief Well effMODuent(well                                                                                 Flow Reservoir Relief Well effluent (wells 196-268)                                 Intermittent                         100 ii.                           a 4'
.(days/mo.)  
41 ii 4'
.(mo./year)
r                             II JI TCEQ-1 0055 (05/15/2012) Industrial Wastewater Permit Application Technical Report                                 Page 7 of 66
Pumped X Gravity Measurement Device: Estimate Xintermittent -Seasonal
 
__Continuous Rebutlng Relief Well effMODuent(well Flow Reservoir Relief Well effluent (wells 196-268) Intermittent 100 ii. a 4'41 ii 4'r II JI TCEQ-1 0055 (05/15/2012)
Attachment NOC-AE-14003142 Page 34 of 155 OUTFALL:             005 Latitude                       Longitud6'.-'.'".                                       Locat.i. Descr.ptlon"-
Industrial Wastewater Permit Application Technical Report Page 7 of 66 Attachment NOC-AE-14003142 Page 34 of 155 OUTFALL: 005 Latitude Longitud6'.-'.'".
28           44     32         96           02           4     At the discharge of flowing relief wells, prior to mixing i'trmltteddFoib   MG6).       Proposed   i   low (!GiiDGt)     with the East Fork Little Robbins Slough D~y ~yAg Dl   AgMax      OlyMax                                                     isc ~baeDuration n/a         n/a               n/a             n/a           _         (hrs./day) _                     (days/mo.) _             (mo./year)
Locat.i. Descr.ptlon"-
Pumped X Gravity       Measurement Device: Estimate                             X     Intermittent           -seasonal   ___Continuous Wate RontaibrtI re       aief Wele                                                       .nttal Vowele (MG64)                                       F Reservoir Relief Well effluent (wells 269-483)                                     Intermittent                             100 It it It It                                           tI II
28 44 32 96 02 4 At the discharge of flowing relief wells, prior to mixing i'trmltteddFoib MG6). Proposed i low (!GiiDGt) with the East Fork Little Robbins Slough D~y Ag Dl Max ~y Ag OlyMax isc ~baeDuration n/a n/a n/a n/a _ (hrs./day)
                                                                                .11                                           ii OUTFALL:       006 Latitud         ~             Longitude;:..               .ocapn-,-
_ (days/mo.)
14l I~'~r~m~!t~ted       M1 31        _96          03I dFl*   (MGD)ji 36    At the discharge of flowing relief wells, prior to mixing with Little Robbins Slough Dl~v ~l;a)<             bl&#xfd;-               lMax                                           ishrbutdn n/a         n/a               n/a             n/a                     (hrs./day)                       (days/mo.)               ,(mo./year)
_ (mo./year)
-Pumped           X Gravity     Measurement Device: Estimate                     ,       X     Intermittent ____Seasonal ____Continuous
Pumped X Gravity Measurement Device: Estimate X Intermittent -seasonal
                                  .' iii,;               .-..                    ..on
___Continuous RontaibrtI re Wate aief Wele Vowele (MG64) .nttal F Reservoir Relief Well effluent (wells 269-483) Intermittent 100 It it It It tI II.11 ii OUTFALL: 006 Latitud ~ Longitude;:.. .ocapn-,-14 31 _96 03I 36 At the discharge of flowing relief wells, prior to mixing I~'~r~m~!t~ted 1 l M dFl* (MGD)ji with Little Robbins Slough Dl~v ~l;a)< bl&#xfd;- lMax ishrbutdn n/a n/a n/a n/a (hrs./day) (days/mo.)  
                                                                                      ;. V ",.".:...'.,.,'...
,(mo./year)-Pumped X Gravity Measurement Device: Estimate , X Intermittent
                                                                                          ""'. i n e M         b".. .,'' ".       ,T*:.'lo        ,>
____Seasonal
Reservoir Relief Well effluent (wells 483-670)                                   Intermittent                             100
____Continuous.on ;. .' iii,; .-.. .""'. ",.".:...'.,.,'...
                                                                                -e                                           a
V i n e M b ".. .,'' ". ,>Reservoir Relief Well effluent (wells 483-670) Intermittent 100-e a-ft It-t It II H-e II -I TCEQ-10055 (0511612012)
                                                                                -ft                                         It
Industrial Wastewater Permit Application Technical Report Page 7b of 66 Attachment NOC-AE-14003142 Page 35 of 155 OUTFALL: 101.Lattude -ongltude' Location Description 2Where low volume waste sources commingled with previously monitored: l i .; effluents are discharged from the neutralization beslns prior to mixing with other Permitted Flodw (MGD) Proposed lF1oW (MGO) waste stream DyAvg OlyMax' A Dly Max on n/a n/a n/a n/a n/a_ (hrs./day) n/a (days/mo.)
                                                                                -t                                           It II                                           H
n/a (mo,/year)
                                                                                  -e II                               -         I TCEQ-10055 (0511612012) Industrial Wastewater Permit Application Technical Report                                         Page 7b of 66
X Pumped -Gravity Measurement Device: totalizer X Intermittent Seasonal Continuous t at~ras Volume (MOP) % ifll No1W Low volume waste sources commingled with 0.25** 100 previously monitored effluents from the metal cleaning waste system discharge Stormwater
 
*At discharge into the MCR**Total outfall flow, average Sep 12 -Apr 14 OUTFALL: 201-Latitude'I -Lngtud.* .ILocatfon Descrfiiption 28 47 3 96 03 07 Where low volume waste sources are discharged from the oily waste.( GD) treatment system prior to mixing with any other waste stream-Permtited FloW ropose d F'V(M D 9~g t)ya D~Avg Diy Max ishageJuat na n/a n/a n/a fl/a (r.dy a (days/mo.)  
Attachment NOC-AE-14003142 Page 35 of 155 OUTFALL:               101
.2/a (mo./year~.Pumped_
        .Lattude                 -       ongltude'                                         Location Description 2Where low volume waste sources commingled with previously monitored
Gravity Measurement Device:_totalizer X Intermittent
: l   i       .   ;   effluents are discharged from the neutralization beslns prior to mixing with other Permitted Flodw (MGD)           Proposed lF1oW (MGO)           waste stream DyAvg     OlyMax'               A         Dly Max                                                           on n/a             n/a               n/a           n/a             n/a_     (hrs./day) n/a           (days/mo.) n/a             (mo,/year)
____,Seasonal
X Pumped     -Gravity         Measurement Device: totalizer                       X Intermittent           Seasonal           Continuous t       at~ras                                                             Volume (MOP)                     %         ifll No1W Low volume waste sources commingled with                                             0.25**                             100 previously monitored effluents from the metal cleaning waste system discharge Stormwater
___Continuous CotiuigWasteitraams:
                    *At discharge into the MCR
s- Volm I MD OA 6hf Toailo Low volume waste sources from the oily waste O.019** 100 treatment system_________
        **Total outfall flow, average Sep 12 - Apr 14 OUTFALL: 201
_________Stormwater
        -Latitude'I                   -Lngtud.*                                           .ILocatfon Descrfiiption 28         47         3         96       03         07     Where low volume waste sources are discharged from the oily waste
*At discharge into theMCR _________**Total outfall flow, average Sep 12 -Apr 14 TCEQ-1 0055 (05/15/2012)
                    .( GD)                                       treatment system prior to mixing with any other waste stream
Industrial Wastewater Permit Application Technical Reportg Page 7c of 66 Attachment NOC-AE-14003142 Page 36 of 155 OUTFALL: 401-Latltude*
-Permtited FloW                     ropose d F'V(M D 9~g t)ya                   D~Avg           Diy Max                                       ishageJuat na n/a                           n/a           n/a             fl/a     (r.dy             a     (days/mo.) .2/a             (mo./year
Longltude' Locatloh bes Srlotion 28 47"' 35 ""96""-03j  
  ~.Pumped_         Gravity     Measurement Device:_totalizer                       X   Intermittent ____,Seasonal ___Continuous CotiuigWasteitraams:s-                                                             Volm I     MD                   OA6hf Toailo Low volume waste sources from the oily waste                                           O.019**                             100 treatment system_________                                                               _________
&#xfd;7 At discharge from the sewage treatment plant (West Sanitary Waste P ..a.i &#xfd;Wtted Flow (MGD) Proposed Flow (MGD) Treatment System) prior to mixing with any other waste stream Oly AV g Dly Max Dly AVO PlMY rpchrx D ation, n/a n/a n/a n/a n/a (hrs,/day) n/a (days/mo.)
Stormwater
n/a (mo./year)
                      *At discharge into theMCR                                   _________
X pumpedGravlty Measurement.Device:
          **Total outfall flow, average Sep 12 - Apr 14 TCEQ-1 0055 (05/15/2012) Industrial Wastewater Permit Application Technical Reportg                                     Page 7c of 66
ultrasonic X Intermittent
 
__Seasonal Continuous Treated sanitary sewage commingled with car 0.021* 100 wash water and air conditioning condensate Stormwater
Attachment NOC-AE-14003142 Page 36 of 155 OUTFALL:                 401
*At discharge into the MCR**Total outfall flow, average Sep 12- Apr 14 OUTFALL: 501 Latltucie*
      - Latltude*                               Longltude'                                           Locatloh   besSrlotion 28         47"'         35     ""96""-03j                       &#xfd;7     At discharge from the sewage treatment plant (West Sanitary Waste
Longitude$'..
    &#xfd;Wtted Flow (MGD)
Lo'batidoh bes;rp n, 28 47 39 96 02 52 Where metal cleaning wastes are discharged prior toproposed Flow (MGD) mixing with any other waste stream~O~~v~ WyMa Wyvg JliMax .> Di&#xfd;cage Durftnori, n/a n/a n/a n/a n/a (hrs./day) n/a (days/mo.)
P..a.i                                  Proposed Flow (MGD)                 Treatment System) prior to mixing with any other waste stream Oly AV g           Dly Max           Dly AVO             PlMY rpchrx                                             D     ation, n/a               n/a               n/a                   n/a           n/a       (hrs,/day) n/a         (days/mo.) n/a         (mo./year)
2/a (mo,/year)
X pumpedGravlty                   Measurement.Device: ultrasonic                           X Intermittent __Seasonal               Continuous Treated sanitary sewage commingled with car                                                   0.021*                         100 wash water and air conditioning condensate Stormwater
X PumpedGravlty Measurement Device: estimate X Intermittent
                        *At discharge into the MCR
___Seasonal Continuous 777 7 7 .....Cd.-r ,-t..ri -. .u.ti.ng :-: W t
          **Total outfall flow, average Sep 12- Apr 14 OUTFALL: 501 Latltucie*                             Longitude$'..                                       Lo'batidoh bes;rp       n, 28         47           39           96             02           52     Where metal cleaning wastes are discharged prior to
-;. .. ..
:.:r*.      d*:Fl.O.        G*I'o proposed Flow(MGD)                        mixing with any other waste stream
.; .V -..GD of O ai~ W Metal cleaning waste n/a** R/a**Stormwater
              ~O~~v~ WyMa               Wyvg             JliMax                                   .>   Di&#xfd;cage Durftnori, n/a               n/a               n/a                   n/a           n/a       (hrs./day)   n/a     (days/mo.) 2/a         (mo,/year)
*Prior to mixing with Outfall_101
X PumpedGravlty                   Measurement Device: estimate                             X   Intermittent ___Seasonal           Continuous Cd.-r ,-t..ri -. .u.ti.ng                                                                                 777  7 7 W t :-: .*..e..:..*.-.'..,:,- -;.. :*...*
"*There has been no discharge from this outfall since Dec 1992 TCEQ-1 0055 (05/15/2012)
                                                              ..     *-*.\..*.,...  ; . -...V                  GD    .....
Industrial Wastewater Permit Application Technical Report Page 7d of 66 Attachment NOC-AE-14003142 Page 37 of 155 OUTFALL: 601 Latitude " Longitude  
of O ai~ W Metal cleaning waste                                                     n/a**                         R/a**
: Location.Descriptnon 28 I47 I15 96 02 [10 At discharge from the sewage treatment plant (Training Sanitary.eritt..ed"low."(MD)i P.rop, d! FlOw (M".. Waste Treatment Facility) prior to mixing with any other waste stream Diy.:0' bI j , lM'ax:'by'i~
Stormwater
D OyWMax Dilscharge'ltiral n/a n/a n/a n/a rna (hrs./day) n/a (days/mo.)
                      *Prior to mixing with Outfall_101
_.a_(mo./year)
"*There has been no discharge from this outfall since Dec 1992 TCEQ-1 0055 (05/15/2012) Industrial Wastewater Permit Application Technical Report                                         Page 7d of 66
X Pumped Gravity Measurement Device: ultrasonic  
 
-X Intermittent
Attachment NOC-AE-14003142 Page 37 of 155 OUTFALL:                   601 Latitude         "               Longitude             :                             Location.Descriptnon 28     I47           I15           96             02   [10     At discharge from the sewage treatment plant (Training Sanitary
_ Seasonal _ Continuous Contribuit ing ast btr~ams -Vollume d(MG 13 .13) To TotalF oW.Treated sanitary sewage commingled with air 0.018"* 100 conditioning condensate and HVAC cooling tower blowdown Stormwater
.eritt..ed"low."(MD)i               P.rop,     d! FlOw (M"..       Waste Treatment Facility) prior to mixing with any other waste stream Diy.:0'j         bIlM'ax:'by'i~
*At discharge into the MCR**Total outfall flow, average Sep 12 -Apr 14 OUTFALL: Latitude Longitude .LctnDeriion el Iow GO) Proposed Flow (MGD)I'y Avg Dly Max D!yAV9j :~Max~ i'~~i~Drtion'(hrs./day) (days/mo.)
                        ,          D                   OyWMax                                   Dilscharge'ltiral n/a               n/a             n/a               n/a         rna       (hrs./day) n/a           (days/mo.) _.a_(mo./year)
_.(mo./year)
X Pumped               Gravity   Measurement Device: ultrasonic         -             X     Intermittent _     Seasonal _             Continuous Contribuit ing         ast btr~ams                 -                                       Vollumed(MG13    .13)                   TotalF oW.
-Pumped Gravity Measurement Device:_, Intermittent -Seasonal
To Treated sanitary sewage commingled with air                                           0.018"*                               100 conditioning condensate and HVAC cooling tower blowdown Stormwater
____continuous Contributing Wastestreams: -oiu i' MGb) .of iofM :7?'r It II ii 41. 41 it. II L .41 TCEQ-1 0055 (05/15/2012)
                        *At discharge into the MCR
Industrial Wastewater Permit Application Technical Report Page 7e of 66 Attachment NOC-AE-14003142 Page 38 of 155 a. Does y our facility use any coolingtowers or boilers that discharge blowdown or other wastestreams to the outfall(s)?
            **Total outfall flow, average Sep 12 - Apr 14 OUTFALL:
ELI Yes El No b. Does your facility discharge once-through cooling water to the outfall(s)?
Latitude                         Longitude                         .LctnDeriion el Iow           GO)     Proposed Flow (MGD)
LiYes FII No c. If yes to either item a or b, indicate with a check mark that the appropriate MSDS with the following information for each chemical additive was submitted with the application.
I'y Avg         Dly   Max       D!yAV9j               :~Max~                                                   i'~~i~Drtion' (hrs./day)               (days/mo.)               _.(mo./year)
71 Manufacturers Product Identification Number.7] Product use. (e.g., biocide, fungicide, corrosion inhibitor, etc.)P1 Chemical Composition including Chemical Abstracts System (CAS) number for each ingredient.
-     Pumped           Gravity   Measurement Device:_,                                     Intermittent   -Seasonal             ____continuous Contributing Wastestreams:               -oiu                                                     i' MGb)       .               of         iofM :7?'
r                                 It II                     ii
: 41.                               41 it.                               II L                                 .41 TCEQ-1 0055 (05/15/2012) Industrial Wastewater Permit Application Technical Report                                         Page 7e of 66
 
Attachment NOC-AE-14003142 Page 38 of 155
: a. Does y our facility use any coolingtowers or boilers that discharge blowdown or other wastestreams to the outfall(s)? ELI Yes El No
: b. Does your facility discharge once-through cooling water to the outfall(s)? LiYes FII No
: c. If yes to either item a or b, indicate with a check mark that the appropriate MSDS with the following information for each chemical additive was submitted with the application.
71   Manufacturers Product Identification Number.
7]   Product use. (e.g., biocide, fungicide, corrosion inhibitor, etc.)
P1 Chemical Composition including Chemical Abstracts System (CAS) number for each ingredient.
LI Classify product as non-persistent, persistent, or bloaccumulative.
LI Classify product as non-persistent, persistent, or bloaccumulative.
H Product or active ingredient half-life.
H Product or active ingredient half-life.
71 Frequency of product use (e.g., 2 hr/day once every two weeks).RV Product toxicity data specific to fish and aquatic invertebrate organisms.
71 Frequency of product use (e.g., 2 hr/day once every two weeks).
71 Concentration of whole product in wastestream (if above item is for whole product)E] Concentration of active ingredient in wastestream (if above item is for active ingredient)
RV Product toxicity data specific to fish and aquatic invertebrate organisms.
71 Concentration of whole product in wastestream (if above item is for whole product)
E] Concentration of active ingredient in wastestream (if above item is for active ingredient)
Please provide a summary of this information in a ddition to the submittal o f the M SDS for each specific w astestream an d the associated ch emical a dditives and specify which outfalls are affected.
Please provide a summary of this information in a ddition to the submittal o f the M SDS for each specific w astestream an d the associated ch emical a dditives and specify which outfalls are affected.


==Attachment:==
==Attachment:==
 
I
I d. Cooling Towers and Boilers Number of Units Daily Avg. Blowdown Dally Max Blowdown Cooling Towers 1 cooling towers Dally Avg: 7,200 gallons/day Dally Max: 17,280 gallons/day Boilers 1 boilers Daily Avg:
: d. Cooling Towers and Boilers Number of Units                 Daily Avg. Blowdown                 Dally Max Blowdown Cooling Towers     1       cooling towers       Dally Avg: 7,200         gallons/day Dally Max:   17,280 gallons/day Boilers             1         boilers             Daily Avg:
* gallons/day Dally Max:
* gallons/day Dally Max:
* gallons/day
* gallons/day
.*4,022 rox matl d&#xa5;s e1 ear Are there any existing or proposed outfalls which discharge stormwater runoff commingled with other wastestreams?
          .*4,022 gpd.*fo-a,,p rox matl             d&#xa5;s       e1 ear Are there any existing or proposed outfalls which discharge stormwater runoff commingled with other wastestreams?
[0 Yes FH No. If yes, provide the following information.
[0 Yes FH No. If yes, provide the following information. If no, proceed to Item No. 7.
If no, proceed to Item No. 7.a. Provide a brief n arrative description of the industrial processes and a ctivities t hat occur outdoors or in some manner that may result in exposure of the materials to precipitation or runoff in areas where runoff is generated.
: a. Provide a brief n arrative description of the industrial processes and a ctivities t hat occur outdoors or in some manner that may result in exposure of the materials to precipitation or runoff in areas where runoff is generated.
Storm water drainage from production and non-production areas Is discharged through permitted outfalls or under the TPDES Storm Water General Permit. For production areas, at least the first flush of stormwater runoff from SPOC sources and production equipment areas is collected and treated by the Oily Waste Treatment Systems (Outfall 201). Secondary containment is provided for chemical and other storage tank areas.TCEQ-10055 (0511612012)
Storm water drainage from production and non-production areas Is discharged through permitted outfalls or under the TPDES Storm Water General Permit. For production areas, at least the first flush of stormwater runoff from SPOC sources and production equipment areas is collected and treated by the Oily Waste Treatment Systems (Outfall 201). Secondary containment is provided for chemical and other storage tank areas.
Industrial Wastewater Permit Application Technical Report Page 8 of 66 Attachment NOC-AE-14003142 Page 39 of 155 D7 EOXM4RTICS SWAGE~ SWAXf MIIGE A 4D/RSPAT?
TCEQ-10055 (0511612012) Industrial Wastewater Permit Application Technical Report                       Page 8 of 66
MANA1M~'7 ANN PVSA(~ SEPTAa~4~
 
V, WAGPA a. Please check the appropriate method(s) of domestic sewage and domestic sewage sludge treatment/disposal and complete Attachment F if directed.[] Domestic sewage is not generated on-site. PROCEED TO ITEM NO. 8.-Both do mestic and industrial treatment sludge ARE commingled prior to use or disposal.
Attachment NOC-AE-14003142 Page 39 of 155 D7 EOXM4RTICS       SWAGE~           SWAXf             MIIGE A 4D/RSPAT? MANA1M~
PROCEED TO ITEM NO. 8.121 Industrial wastewater and domestic sewage are treated separately and the respective sludge IS NOT commingled prior to sludge use or disposal COMPLETE WORKSHEET 5.0 OF THIS APPLICATION.
'7 ANN                                                                                 PVSA(~
SEPTAa~4~
V, WAGPA
: a. Please check the appropriate method(s) of domestic sewage and domestic sewage sludge treatment/disposal and complete Attachment F if directed.
[] Domestic sewage is not generated on-site. PROCEED TO ITEM NO. 8.
      -   Both do mestic and industrial treatment sludge ARE commingled prior to use or disposal. PROCEED TO ITEM NO. 8.
121 Industrial wastewater and domestic sewage are treated separately and the respective sludge IS NOT commingled prior to sludge use or disposal COMPLETE WORKSHEET 5.0 OF THIS APPLICATION.
[] If your facility is a POTW, COMPLETE WORKSHEET 5.0 OF THIS APPLICATION.
[] If your facility is a POTW, COMPLETE WORKSHEET 5.0 OF THIS APPLICATION.
F] Facility is connected t o a wastewater treatment plant permitted t o receive domestic sewage, or the domestic sewage is transported off-site to a permitted facility for treatment and/or disposal.
F] Facility is connected t o a wastewater treatment plant permitted t o receive domestic sewage, or the domestic sewage is transported off-site to a permitted facility for treatment and/or disposal. COMPLETE ITEM NO. 7.11.
COMPLETE ITEM NO. 7.11.n Domestic sewage is disposed of by an on-site septic tank. COMPLETE ITEM 7.B.T- Other: Please provide a detailed description below.b. Provide t he name and TC EQ, NPDES, and/or TPDES Permit N o. of t he waste disposal facility which receives the domestic sewage/septage.
n   Domestic sewage is disposed of by an on-site septic tank. COMPLETE ITEM 7.B.
If hauled by motorized vehicle, provide the name and TCEQ Registration No. of the hauler.N/A Is the p ermittee currently required t o meet any implementation schedule for compliance or enforcement?
T- Other: Please provide a detailed description below.
E] Yes W] No If yes, provide a brief summary of the requirements and a status update.TCEQ-10055 (05115/2012)
: b. Provide t he name and TC EQ, NPDES, and/or TPDES Permit N o. of t he waste disposal facility which receives the domestic sewage/septage. If hauled by motorized vehicle, provide the name and TCEQ Registration No. of the hauler.
Industrial Wastewater Permit Application Technical Report Page 1) of 66 Attachment NOC-AE-14003142 Page 40 of 155 Have any biological tests for acute or chronic toxicity been made on any of your discharges or.on a receiving water in relation to your discharge within the last three (3) years?El Yes l] No If yes, identify the tests and describe their purposes below. Please attach a copy of all tests performed that have not been previously sent to the TCEQ and/or EPA.There has been no discharge via Outfall 001 since 1997. The facility will perform the required testing when discharges occur.P ~~a YOPSIETfI V.A%~~ (1-ftcii, pge )Do you receive wastes from off-site sources for treatment in your facility, disposal on-site via land. application, and/or discharge via a permitted outfall El Yes V No If no, proceed to Item No. ii. If yes, proceed as directed.a. Indicate with a check mark that a detailed attachment with the following information was provided with the application:
N/A Is the p ermittee currently required t o meet any implementation schedule for compliance or enforcement? E] Yes                   W] No If yes, provide a brief summary of the requirements and a status update.
F-1 List of wastes received Identified sources of wastes received-- Characterization of wastes receivedH Name and addresses of generators 8 Volumes of each waste received Description of the relationship of Info. on compatibility with on-site wastes waste source(s) with your facility's activities.
TCEQ-10055 (05115/2012) Industrial Wastewater Permit Application Technical Report               Page 1)of 66
 
Attachment NOC-AE-14003142 Page 40 of 155 Have any biological tests for acute or chronic toxicity been made on any of your discharges or.
on a receiving water in relation to your discharge within the last three (3) years?
El Yes l] No If yes, identify the tests and describe their purposes below. Please attach a copy of all tests performed that have not been previously sent to the TCEQ and/or EPA.
There has been no discharge via Outfall 001 since 1997. The facility will perform the required testing when discharges occur.
P ~~a                                 YOPSIETfI(1-ftcii,V.A%~~             pge )
Do you receive wastes from off-site sources for treatment in your facility, disposal on-site via land. application, and/or discharge via a permitted outfall El Yes V No If no, proceed to Item No. ii. If yes, proceed as directed.
: a. Indicate with a check mark that a detailed attachment with the following information was provided with the application:
F-1 List of wastes received                                             Identified sources of wastes received 8 -- Characterization of wastes receivedH Volumes of each waste received Info. on compatibility with on-site wastes Name and addresses of generators Description of the relationship of waste source(s) with your facility's activities.
Attachlnent:
Attachlnent:
: b. Is wastewater from a TCEQ, NPDES, and/or TPDES permitted facility commingled with your wastewater after your final treatment and prior to discharge via your final outfall/point of disposal?
: b. Is wastewater from a TCEQ, NPDES, and/or TPDES permitted facility commingled with your wastewater after your final treatment and prior to discharge via your final outfall/point of disposal? E] Yes                   n- No If yes, provide the name, address, and TCEQ, NPDES, and/or TPDES permit number of the co ntributing facility an d a copy of any agreements an d/or contracts r elating t o t his activity.
E] Yes n- No If yes, provide the name, address, and TCEQ, NPDES, and/or TPDES permit number of the co ntributing facility an d a copy of any agreements an d/or contracts r elating t o t his activity.c. Is your facility a Publicly Owned Treatment Works (POTW) that accepts process wastewater from any Significant Industrial User (SIU) and has or is required to have an approved pretreatment program under the NPDES/TPDES program? El Yes 11 No If yes, complete Worksheet 6.o of this application.
: c. Is your facility a Publicly Owned Treatment Works (POTW) that accepts process wastewater from any Significant Industrial User (SIU) and has or is required to have an approved pretreatment program under the NPDES/TPDES program?                                   El Yes 11 No If yes, complete Worksheet 6.o of this application.
Are radioactive materials mined, used, stored, or processed at this facility?
Are radioactive materials mined, used, stored, or processed at this facility?                       2 Yes [] No If yes, Provide alist of the materials and the r esults of one analysis of your effluent in picocuries per liter (pCi/L) for all radioactive parameters which may be present.
2 Yes [] No If yes, Provide alist of the materials and the r esults of one analysis of your effluent in picocuries per liter (pCi/L) for all radioactive parameters which may be present.Radioactive Materials Conc. (pCi/L)Nuclear fuel (CAS no. 7440-61-1)  
Radioactive Materials                                                                         Conc. (pCi/L)
---**There has been no discharge via Outfall 001 since 1997.TCEQ-10055 (05/10/2012)
Nuclear fuel (CAS no. 7440-61-1)                                                                       --- *
Industrial Wastewater Permit Application Technical Report Page 10 of 66 Attachment NOC-AE-14003142 Page 41 of 155 THE FO LLOWING ITEMS ARE ONLY REQUIRED FOR EXISTING PERMITTED FACILITIES.
*There has been no discharge via Outfall 001 since 1997.
Are you requesting a major amendment of an existing permit? 71 Yes F] No If yes, list each specific request and provide discussion on the scope of any requested permit changes.See Attachment J If necessary, provide supplemental information or additional data that will support the request.Are you requesting any minor modifications to the permit? RV Yes E- No Note: see the instructions for an exclusive list of changes considered as minor modifications.
TCEQ-10055 (05/10/2012) Industrial Wastewater Permit Application Technical Report                     Page 10 of 66
If yes, list and discuss the requested changes.Please revise the definition for "total residual chlorine" provided In Other Requirement No. 4 to be consistent with the current definition for "total residual chlorine" in 40 CFR 423 that reads as follows: "The term total residual chlorine (or total residual oxidants for Intake water with bromides) means the value obtained using any of the "chlorine-total residual" methods in Table IB in 40 CFR 136.3(a), or other methods approved by the permitting authority." Are you requesting any minor amendments to the permit? ___Yes , No If yes, list and discuss the requested changes.TCEQ-1 0055 (05115/2012)
 
IndustrIal Wastewater Permit Application Technical Report Page I1I of 66 Attachment NOC-AE-14003142 Page 42 of 155 WORKSHEETS TO THE INDUSTRIAL WASTEWATER PERMIT APPLICATION TECHNICAL REPORT Please review the worksheet requirements in the instructions and indicate by checking either yes or no which worksheets are required, completed, and submitted with the technical report.Worksheets that are not applicable do not need to be submitted with the technical report.COMPLETED AND SUMI'JTED WITF ,WORKSHJEET I THET CHNIt RIEPORT:-YES NO 1.0: EPA EFFLUENT CATEGORICAL GUIDELINES  
Attachment NOC-AE-14003142 Page 41 of 155 THE FO LLOWING ITEMS ARE ONLY REQUIRED FOR EXISTING PERMITTED FACILITIES.
[]1 F]1 2.0: POLLUTANT ANALYSES REQUIREMENTS  
Are you requesting a major amendment of an existing permit?                               71 Yes F] No If yes, list each specific request and provide discussion on the scope of any requested permit changes.
[ElF 3.0: LAND DISPOSAL OF EFFLUENT[7[]
See Attachment J If necessary, provide supplemental information or additional data that will support the request.
3-1 SURFACE LAND DISPOSAL OF EFFLUENT [ 7 3.2: SUBSURFACE LAND DISPOSAL OF EFFLUENT [I] R(]3-3 SUBSURFACE AREA DRIP DISPERSAL SYSTEM LAND E7] o7 DISPOSAL OF EFFLUENT 4.0: RECEIVING WATERS [7 F]4.1: STREAM PHYSICAL CHARACTERISTICS WORKSHEET Di 7]5.0: SEWAGE SLUDGE MANAGEMENT AND DISPOSAL [71 [E]6.0: INDUSTRIAL WASTE CONTRIBUTION  
Are you requesting any minor modifications to the permit?                             RV Yes E- No Note: see the instructions for an exclusive list of changes considered as minor modifications.
[7 [7 7.0: STORM WATER RUNOFF Z~7 El 8.o: AQUACULTURE[]
If yes, list and discuss the requested changes.
7 9.0: CLASS V INJECTION WELL I]7 10.0: QUARRIES IN THE JOHN GRAVES SCENIC RIVERWAY 7 7 TCEQ-10055 (05/15/2012)
Please revise the definition for "total residual chlorine" provided In Other Requirement No. 4 to be consistent with the current definition for "total residual chlorine" in 40 CFR 423 that reads as follows:
Industrial Wastewater Permit Application Technical Report Page 12 of 66 Attachment NOC-AE-14003142 Page 43 of 155 Worksheet 1.0 EPA Effluent Categorical Guidelines Attachment NOC-AE-14003142 Page 44 of 155 WORKSHEET 1.o EPA EFFLUENT CATEGORICAL GUIDELINES REQUIRED FOR ALL APPLICATIONS FOR TPDES PERMITS FOR DISCHARGES OF WASTEWATERS SUBJECT TO EPA EFFLUENT LIMITATION GUIDELINES.
"The term total residual chlorine (or total residual oxidants for Intake water with bromides) means the value obtained using any of the "chlorine-total residual" methods in Table IB in 40 CFR 136.3(a), or other methods approved by the permitting authority."
Is your facility subject to any of the 40 CFR effluent guidelines outlined in Table I?E-I Yes n.No If yes, provide the appropriate information in the table below. I f no, this worksheet is not required.IndustryCFR Steam Electric Generating Station 423 a. Production data: Provide the appropriate data for effluent guidelines with production based effluent limitations.
Are you requesting any minor amendments to the permit? ___Yes                               , No If yes, list and discuss the requested changes.
Sub:ategory Uc.... D.. .. .... Units-: i QuanUttY/Day N/A b. Organic Chemicals, P lastics, and S ynthetic Fibers Ma nufacturing Data (40 CFR Part 414): Provide each appropriate subpart and the percent of total production.
TCEQ-1 0055 (05115/2012) IndustrIal Wastewater Permit Application Technical Report                 Page I1Iof 66
Also provide the appropriate data for metal bearing wastestreams as required in 40 CFR Part 414, Appendices A and B.N0 Aof totallApendixA andB Suctgr productio.iMtl rcs NIA _ _ _ _ _ _ _ _TCEQ-10055 (05/15/2012)
 
Industrial Wastewater Permit Application Technical Report Page 13 of 66 Attachment NOC-AE-14003142 Page 45 of 155 c. Refineries (40 CFR Part 419): Provide the applicable subcategory and a brief justification for each.N/A 0OCES NOW~&ESWS.
Attachment NOC-AE-14003142 Page 42 of 155 WORKSHEETS TO THE INDUSTRIAL WASTEWATER PERMIT APPLICATION TECHNICAL REPORT Please review the worksheet requirements in the instructions and indicate by checking either yes or no which worksheets are required, completed, and submitted with the technical report.
X~~l6S M6~d eaire~dw fpo See Flow diagrams, Attachment H to~V1fen e- 9ti~K~ "p.-t t nea pg4~ .r S Process E .PA Guidleline Date Process/PIart Subp .art Construction.
Worksheets that are not applicable do not need to be submitted with the technical report.
P. olmmenced Units I and 2 423 N/A 1975 Units 3 and 4 423. N/A Near future TCEQ-1 0055 (05116/2012)
COMPLETED AND SUMI'JTED WITF
Industrial Wastewater Permit Application Technical Report Page 14 of 66 Attachment NOC-AE-14003142 Page 46 of 155 Worksheet
,WORKSHJEET                                                                         ITHET      CHNIt RIEPORT:-
YES           NO 1.0:   EPA EFFLUENT CATEGORICAL GUIDELINES                                           []1           F]1 2.0:   POLLUTANT ANALYSES REQUIREMENTS                                               [ElF 3.0:   LAND DISPOSAL OF EFFLUENT[7[]
3-1     SURFACE LAND DISPOSAL OF EFFLUENT                                             [             7 3.2:   SUBSURFACE LAND DISPOSAL OF EFFLUENT                                           [I]           R(]
3-3     SUBSURFACE AREA DRIP DISPERSAL SYSTEM LAND                                     E7]           o7 DISPOSAL OF EFFLUENT 4.0:   RECEIVING WATERS                                                               [7           F]
4.1:   STREAM PHYSICAL CHARACTERISTICS WORKSHEET                                     Di           7]
5.0:   SEWAGE SLUDGE MANAGEMENT AND DISPOSAL                                         [71           [E]
6.0:   INDUSTRIAL WASTE CONTRIBUTION                                                 [7           [7 7.0:   STORM WATER RUNOFF                                                             Z~7 El 8.o: AQUACULTURE[]                                                                                   7 9.0:   CLASS V INJECTION WELL                                                         I]7 10.0: QUARRIES IN THE JOHN GRAVES SCENIC RIVERWAY                                   7             7 TCEQ-10055 (05/15/2012) Industrial Wastewater Permit Application Technical Report           Page 12 of 66
 
Attachment NOC-AE-14003142 Page 43 of 155 Worksheet 1.0 EPA Effluent Categorical Guidelines
 
Attachment NOC-AE-14003142 Page 44 of 155 WORKSHEET 1.o EPA EFFLUENT CATEGORICAL GUIDELINES REQUIRED FOR ALL APPLICATIONS FOR TPDES PERMITS FOR DISCHARGES OF WASTEWATERS SUBJECT TO EPA EFFLUENT LIMITATION GUIDELINES.
Is your facility subject to any of the 40 CFR effluent guidelines outlined in Table I?
E-IYes n.No If yes, provide the appropriate information in the table below. I f no, this worksheet is not required.
IndustryCFR Steam Electric Generating Station                                                         423
: a. Production data: Provide the appropriate data for effluent guidelines with production based effluent limitations.
Sub:ategory                                                   .. D...   ... Units Uc....
                    -i::;,**    -: i       QuanUttY/Day                   jQuantityiDa.,.*
N/A
: b. Organic Chemicals, P lastics, and S ynthetic Fibers Ma nufacturing Data (40 CFR Part 414): Provide each appropriate subpart and the percent of total production.
Also provide the appropriate data for metal bearing wastestreams as required in 40 CFR Part 414, Appendices A and B.
N0Aof                              totallApendixA                           andB Suctgr                     productio.iMtl                                           rcs NIA                                               _   _   _   _ _ _ _ _
TCEQ-10055 (05/15/2012) Industrial Wastewater Permit Application Technical Report                 Page 13 of 66
 
Attachment NOC-AE-14003142 Page 45 of 155
: c. Refineries (40 CFR Part 419): Provide the applicable subcategory and a brief justification for each.
N/A 0OCES       NOW~&ESWS.     M6~d                    X~~l6S                       eaire~dw     fpo See Flow diagrams, Attachment H to~V1fen                                         e- 9ti~K~   "p.-t t   pg4~
nea        .r S Process                                       .                 EPA Guidleline           Date Process/
PIart     Subp.art       Construction.
P.olmmenced Units I and 2                               423             N/A           1975 Units 3 and 4                                 423.           N/A       Near future TCEQ-1 0055 (05116/2012) Industrial Wastewater Permit Application Technical Report                     Page 14 of 66


===2.0 Pollutant===
Attachment NOC-AE-14003142 Page 46 of 155 Worksheet 2.0 Pollutant Analyses Requirements


Analyses Requirements Attachment NOC-AE-14003142 Page 47 of 155 Worksheet  
Attachment NOC-AE-14003142 Page 47 of 155 Worksheet 2.0 Notes and Additional Information Outfall 001: There has not been a discharge from Outfall 001 since 1997, therefore, the required effluent samples for the application could not be collected.
STP will collect the required samples for the application upon the next available discharge via Outfall 001 and submit the results to the TCEQ for review.
Outfalls 002-006: Effluent data is currently being collected by the facility for these outfalls. The sample result will be submitted at a later date under separate cover.


===2.0 Notes===
Attachment NOC-AE-14003142 Page 48 of 155 WORKSHEET          2.0 POLLUTANT ANALYSES REQUIREMENTS
and Additional Information Outfall 001: There has not been a discharge from Outfall 001 since 1997, therefore, the required effluent samples for the application could not be collected.
* there has not been a discharge via Outfall 001 since 1997.
STP will collect the required samples for the application upon the next available discharge via Outfall 001 and submit the results to the TCEQ for review.Outfalls 002-006: Effluent data is currently being collected by the facility for these outfalls.
REQUIRED FOR APPLICATIONS SUBMITTED FOR A TPDES PERMIT. NOT REQUIRED FOR APPLICATIONS FOR A PERMIT TO DISPOSE OF ALL WASTEWATER BY LAND DISPOSAL OR FOR DISCHARGES SOLELY OF STORM-WATER RUNOFF. (General Requirements: Instructions, Pages 49-51)
The sample result will be submitted at a later date under separate cover.
    'lP6Ilutarnts  iV>!* LD IC
Attachment NOC-AE-14003142 Page 48 of 155 WORKSHEET
    !Outfall Nt."'P0*l-              0 .. *Sam~p,:.
G      .i':*:i!,~~i.*~:.*i.EfU
                              -::i,*:.:-'ii:i;              :}Samp (tc6n  e p.,
:*. !iSam  tain(    gl.: >.Average~
* _Sarnp.,:i* :*i:*i::'.i-BOD.(5-day) .....
CBOD (5-day)
Chemical Oxygen Demand Total Organic Carbon r_.,,                                                          _r_
Dissolved Oxygen Ammonia Nitrogen Total Suspended Solids Nitrate Nitrogen .
Total Organic Nitrogen Total Phosphorus Oil and Grease Total Residual Chlorine Total Dissolved Solids Sulfate Chloride Fluoride              IiiIl Temperature (OF) pH (Standard Units; min/max)_
                                                            *fl    tC',,r ;n          (gI~.. . , . ",.        MA.
Total Aluminum                                                                                                  30 Total Antimony                                                                                                  30 Total Arsenic                                                                                                  10 Total Barium                                                                                                    10 Total Beryllium                                                                                                  5 Total* Cadmium                                                                                                  1 Total Chromium                                                                                                  10 Trivalent Chromium                                                                                      . N/A Hexavalent Chromilum                                                                                          10 Total.Copper                                                                                                  10 Cyanide                                                                                                    ,20 Total Lead                                                                                                      .5 Total Mercury                                                                                                  0.2 Total Nickel                                                                                                  10 Total Selenium                                                                                                10 Total Silver                                                                                                  2.0 Total Thallium                                                                                      _10 Total Zinc                                                                                                      5 TCEQ-10055 (05/16/2012) Industrial Wastewater Permit Application Technical Report                            Page 15 of 66


===2.0 POLLUTANT===
Attachment NOC-AE-14003142 Page 49 of 155 Complete table required for all external outfalls which discharge process wastewater. Partial table required for all external outfalls with n onprocess wastewater discharges. Stormwater runoff discharges commingled with other wastestreams shall complete the table as instructed (Instructions, Pages 49-51).                ,
There has not been a discharge via Outfall 001 since 1997.
Dutfall No.:            ncC IO                              fletCnetatoi.pI)(1
.Pol.utan      /....SAMp':.                                          2 Samp 3.. S.h.S 4 ".Ayerage M.AL (Pg/I.
Benzene                                                                                              10 Benzidine                                                                                            50 Benzo(a)anthracene                                                                      _10 Benzo(a)pyrene                                                                                        10 Carbon Tetrachloride                                                                                  10 Chlorobenzene                                                                                        10 Chloroform                                                                                            10 Chrysene                                                                                              10 Cresols                                                                                              (*2)
Dibromochloromethane                                                      _10 1,2-Dibromoethane                                                                                &#xfd;2 1,4-Dichloro benzene                                                                                  10 1,2:.Dlchloroethane                                                                                  1G0 1,1-Diohloroethylene                                                                                  10 Fluoride                                                                                            .600 Hexachlorobenzene                                                                                    10 Hexachlorobutadlene                                                                                  10 Hexachloroethane                                                                                      20 Methyl Ethyl Ketone                                                                                .50 Nitrobenzene                                                                                          10 n-Nitrosodlethylamlne                                                                                20 n-Nltroso-di-n-Butylamlne                                                                            20 PCB's, Total (*3)                                                                                    1 Pentachlorobenzene                                                                                    20 Pentachlorophenol                                                                                    50 Phenanthrene                                                                      _10 Pyrldlne                                                                                              20 1,2,4,5-Tetrachlorobenzene                                                                            20 Tetrachloroethylene                                                                                  10 Trichloroethylene                                                                                    10 1,1,1.-Trlchloroethane "_10 2,4,6-Trlchlorophenol                                                                                50 TTHM (Total Trihalmethanes)                                                                            10 Vinyl Chloride                                                                                        10
(*1)    Indicates units if different from pg/l.
(*2)    MAL's for Cresols: p-Chloro-m-Creso 10 pg/1; 4,6-Dinitro-o-Cresol 50 pg/i; p-Cresol o0pg/l.
(*3) Total PCB-1242, PCB-1254, PCB-1221, PCB-1232, PCB-1248, PCB-126o, PCB-ioi6.
TCEQ-1 0055 (05/16/2012) Industrial Wastewater Permit Application Technical Report              Page 16 of 66


ANALYSES REQUIREMENTS
Attachment NOC-AE-14003142 Page 50 of 155
* there has not been a discharge via Outfall 001 since 1997.REQUIRED FOR APPLICATIONS SUBMITTED FOR A TPDES PERMIT. NOT REQUIRED FOR APPLICATIONS FOR A PERMIT TO DISPOSE OF ALL WASTEWATER BY LAND DISPOSAL OR FOR DISCHARGES SOLELY OF STORM-WATER RUNOFF. (General Requirements:
: a.     LABORATORY ACCREDITATION:
Instructions, Pages 49-51)!Outfall LD IC G 0 .. (tc6n e tain( gl.:
'lP6Ilutarnts iV>!
:}Samp !iSam p.,
>.Average~
BOD.(5-day)
.....CBOD (5-day)Chemical Oxygen Demand Total Organic Carbon r_.,, _r_Dissolved Oxygen Ammonia Nitrogen Total Suspended Solids Nitrate Nitrogen .Total Organic Nitrogen Total Phosphorus Oil and Grease Total Residual Chlorine Total Dissolved Solids Sulfate Chloride Fluoride IiiIl Temperature (OF)pH (Standard Units;min/max)_*fl tC',,r ;n (gI~. .., .",. MA.Total Aluminum 30 Total Antimony 30 Total Arsenic 10 Total Barium 10 Total Beryllium 5 Total* Cadmium 1 Total Chromium 10 Trivalent Chromium .N/A Hexavalent Chromilum 10 Total.Copper 10 Cyanide ,20 Total Lead .5 Total Mercury 0.2 Total Nickel 10 Total Selenium 10 Total Silver 2.0 Total Thallium _10 Total Zinc 5 TCEQ-10055 (05/16/2012)
Industrial Wastewater Permit Application Technical Report Page 15 of 66 Attachment NOC-AE-14003142 Page 49 of 155 Complete table required for all external outfalls which discharge process wastewater.
Partial table required for all external outfalls with n onprocess wastewater discharges.
Stormwater runoff discharges commingled with other wastestreams shall complete the table as instructed (Instructions, Pages 49-51). , There has not been a discharge via Outfall 001 since 1997.Dutfall No.: ncC IO fletCnetatoi.pI)(1.Pol.utan
/....SAMp':.
2 Samp 3.. S.h.S 4 ".Ayerage M.AL (Pg/I.Benzene 10 Benzidine 50 Benzo(a)anthracene
_10 Benzo(a)pyrene 10 Carbon Tetrachloride 10 Chlorobenzene 10 Chloroform 10 Chrysene 10 Cresols (*2)Dibromochloromethane
_10 1,2-Dibromoethane
&#xfd;2 1,4-Dichloro benzene 10 1,2:.Dlchloroethane 1G0 1,1-Diohloroethylene 10 Fluoride .600 Hexachlorobenzene 10 Hexachlorobutadlene 10 Hexachloroethane 20 Methyl Ethyl Ketone .50 Nitrobenzene 10 n-Nitrosodlethylamlne 20 n-Nltroso-di-n-Butylamlne 20 PCB's, Total (*3) 1 Pentachlorobenzene 20 Pentachlorophenol 50 Phenanthrene
_10 Pyrldlne 20 1,2,4,5-Tetrachlorobenzene 20 Tetrachloroethylene 10 Trichloroethylene 10 1,1,1.-Trlchloroethane
"_10 2,4,6-Trlchlorophenol 50 TTHM (Total Trihalmethanes) 10 Vinyl Chloride 10 (*1)(*2)(*3)Indicates units if different from pg/l.MAL's for Cresols: p-Chloro-m-Creso 10 pg/1; 4,6-Dinitro-o-Cresol 50 pg/i; p-Cresol o0 pg/l.Total PCB-1242, PCB-1254, PCB-1221, PCB-1232, PCB-1248, PCB-126o, PCB-ioi6.TCEQ-1 0055 (05/16/2012)
Industrial Wastewater Permit Application Technical Report Page 16 of 66 Attachment NOC-AE-14003142 Page 50 of 155 a. LABORATORY ACCREDITATION:
Effective July 1, 2oo8, all laboratory tests performed must meet the requirements of 3o TAC Chapter 25, Environmental Testing Laboratory Accreditation and Certification with the following general exemptions:
Effective July 1, 2oo8, all laboratory tests performed must meet the requirements of 3o TAC Chapter 25, Environmental Testing Laboratory Accreditation and Certification with the following general exemptions:
: i. The laboratory is an in-house laboratory and is: 1. periodically inspected by the TCEQ; or 2. located in another state and is accredited or inspected by that state; or 3. performing work for another company with a unit located in the same site; or 4. performing pro bono work for a governmental agency or charitable organization.
: i.       The laboratory is an in-house laboratory and is:
ii. The laboratory is accredited under federal law.iii. The data are needed for emergency-response activities, and a laboratory accredited under the Texas Laboratory Accreditation Program is not available.
: 1.       periodically inspected by the TCEQ; or
iv. The laboratory supplies data for which the TCEQ does not offer accreditation.
: 2.       located in another state and is accredited or inspected by that state; or
The applicant should review 3 o T AC Chapter 2 5 for specific requirements.
: 3.       performing work for another company with a unit located in the same site; or
The following certification statement shall be signed and submitted with very application.
: 4.       performing pro bono work for a governmental agency or charitable organization.
See Instructions, Page 30, for a list of designated representatives who may sign the certification.
ii.     The laboratory is accredited under federal law.
I, Michael P. Murray certify that all laboratory tests submittedwith this application meet the requirements of 3o TAC Chapter 25, Environmental Testing Laboratory Accreditation and Certification.
iii. The data are needed for emergency-response activities, and a laboratory accredited under the Texas Laboratory Accreditation Program is not available.
Partial table (only those pollutants which are required by the conditions specified for each outfall where the pollutant is believed to be present) required for each external outfall where the source is identified.
iv.     The laboratory supplies data for which the TCEQ does not offer accreditation.                     I The applicant should review 3 o T AC Chapter 2 5 for specific requirements. The following certification statement shall be signed and submitted with very application. See Instructions, Page 30, for a list of designated representatives who may sign the certification.
Not required for internal outfalls.* (Instructions, Page 51)a. TRIBUTYLTIN:
I,         Michael P. Murray                             certify that all laboratory tests submittedwith this application meet the requirements of 3o TAC Chapter 25, Environmental Testing Laboratory Accreditation and Certification.
Is your facility or will your proposed facility be an industrial/commercial facility which directly disposes of wastewater from the types of operations listed below or a domestic facility which receive wastewater from the types of industrial/commercial operations listed below? DI Yes 0 No If yes, Indicate with a check mark all of the following criteria which apply and provide the appropriate testing results in the table below.M anufacturers and formulators of tributyltin or related compounds.
Partial table (only those pollutants which are required by the conditions specified for each outfall where the pollutant is believed to be present) required for each external outfall where the source is identified. Not required for internal outfalls.* (Instructions, Page 51)
: a.     TRIBUTYLTIN:
Is your facility or will your proposed facility be an industrial/commercial facility which directly disposes of wastewater from the types of operations listed below or a domestic facility which receive wastewater from the types of industrial/commercial operations listed below? DI Yes                 0 No If yes, Indicate with a check mark all of the following criteria which apply and provide the appropriate testing results in the table below.
M anufacturers and formulators of tributyltin or related compounds.
Painting of ships, boats and marine structures.
Painting of ships, boats and marine structures.
Lj Ship and boat building and repairing, H Ship and boat cleaning, salvage, wrecldng and scaling.Operation and maintenance of marine cargo handling facilities and marinas Facilities engaged in wood preserving LI Any other industrial/commercial facility for which tributyltin is known to be present, or for which there is any reason to believe that tributyltin may be present in the effluent.I TCEQ-1 0055 (05/15/2012)
H Lj   Ship and boat building and repairing, Ship and boat cleaning, salvage, wrecldng and scaling.
Industrial Wastewater Permit Application Technical Report Page 17 of 66 Attachment NOC-AE-14003142 Page 51 of 155 b. ENTEROCOCCI Does your facility or will your proposed facility discharge directly into saltwater receiving waters and: Enterococci bacteria Is expected to be present?Z]Yes 0INo Is domestic wastewater discharged?
Operation and maintenance of marine cargo handling facilities and marinas Facilities engaged in wood preserving LI Any other industrial/commercial facility for which tributyltin is known to be present, or for which there is any reason to believe that tributyltin may be present in the effluent.
W Yes M-No If yes to either question, provide the appropriate testing results in the table below.c. E. coli Does your facility or will your proposed facility discharge directly into fresh water receiving waters and: ElU~l] acteria is expected to be present?VIjYes L1No Is domestic wastewater discharged?
TCEQ-1 0055 (05/15/2012) Industrial Wastewater Permit Application Technical Report               Page 17 of 66
ED Yes [Z No If yes to either question, provide the appropriate testing results in the table below.TABLUE A.:::....Outfall No.: oC oG Effluent Concentration Pollutants Samp. 1 Samp. 2 Samp. 3 Samp. 4 Averagc MAL Tributyltin (gg/1) 0.010 Enterococci (CFU or MPN/1oo ml) N/A E. coli (CFU or MPN/ioo ml) N/A Complete table r equired f or all external outfalls which discharge process wastewater and other wastewaters, which way contain pesticides or herbicides, from a facility which manufactures or formulates pesticides or herbicides.
Not required for internal outfalls.Does your facility manufacture or formulate pesticides or herbicides?
E] Yes [Z No If yes, provide the appropriate testing results."CEQ-10056 (05115/2012)
Industrial Wastewater Permit Application Technical Report Page 18 of 66 Attachment NOC-AE-14003142 Page 52 of 155 D ; EX ... :, &#xfd;.tr f-.' 01)OIitfall No.&#xfd; ZCE ~ ~ f~ihQfoMaln4I
*) A Pdltht.', Saffib.rI SaMp. 2; Ship. 3 Sanip. 4.A:. ' (091I)'Beta-hexachlorocyclohexane 0.05 Carbaryl 5 Chlordane 0.15 Chlorpyrifos 0.05 2,4-D 10 Danitol 4,4-DDD 0.1 4,4'-DDE 0.1 4,4'-DDT 0.1 Demeton 0.2 Diazlnon 0.6 Dloofol 20 Dieldrin 0.1 Diuron 0.09 Endosulfan I (alpha) 0.1 Endosulfan II (beta) 0.1 Endosulfan Sulfate 0.1 Endrln 0.1 Gamma -Hexachlorocyolohexane (Lindane) 0,05 Guthlon 0.10 Heptachlor 0.05 Heptachlor Epoxide 1,0 Hexachlorophene 10 Malathlon 0.10 Methoxychlor


===2.0 Mirex===
Attachment NOC-AE-14003142 Page 51 of 155
0.2 Parathion
: b.      ENTEROCOCCI Does your facility or will your proposed facility discharge directly into saltwater receiving waters and:
Enterococci bacteria Is expected to be present?
Z]Yes        0INo Is domestic wastewater discharged?
W Yes      M-No If yes to either question, provide the appropriate testing results in the table below.
: c.      E. coli Does your facility or will your proposed facility discharge directly into fresh water receiving waters and:
ElU~l] acteria is expected to be present?
VIjYes      L1No Is domestic wastewater discharged?
ED Yes [Z No If yes to either question, provide the appropriate testing results in the table below.
TABLUE A.:::....
Outfall No.:              oC oG                      Effluent Concentration Pollutants                              Samp. 1 Samp. 2 Samp. 3 Samp. 4 Averagc                    MAL Tributyltin (gg/1)                                                                                  0.010 Enterococci (CFU or MPN/1oo ml)                                                                      N/A E. coli (CFU or MPN/ioo ml)                                                                        N/A Complete table r equired f or all external outfalls which discharge process wastewater and other wastewaters, which way contain pesticides or herbicides, from a facility which manufactures or formulates pesticides or herbicides. Not required for internal outfalls.
Does your facility manufacture or formulate pesticides or herbicides?                    E] Yes    [Z No If yes, provide the appropriate testing results.
    "CEQ-10056 (05115/2012) Industrial Wastewater Permit Application Technical Report            Page 18 of 66


===0.1 Toxaphene===
Attachment NOC-AE-14003142 Page 52 of 155
:,&#xfd;.tr f-.' 01) *)
OIitfall No.&#xfd;                    ZCE          ~    D
                                                      ~;      f~ihQfoMaln4I EX ...
A Pdltht.',                                        Saffib.rI SaMp. 2; Ship. 3 Sanip. 4.A:.                  '  (091I)'
Beta-hexachlorocyclohexane                                                                                          0.05 Carbaryl                                                                                                              5 Chlordane                                                                                                          0.15 Chlorpyrifos                                                                                                        0.05 2,4-D                                                                                                                10 Danitol 4,4-DDD                                                                                                            0.1 4,4'-DDE                                                                                                            0.1 4,4'-DDT                                                                                                            0.1 Demeton                                                                                                            0.2 Diazlnon                                                                                                            0.6 Dloofol                                                                                                              20 Dieldrin                                                                                                            0.1 Diuron                                                                                                              0.09 Endosulfan I (alpha)                                                                                                0.1 Endosulfan II (beta)                                                                                                0.1 Endosulfan Sulfate                                                                                                  0.1 Endrln                                                                                                              0.1 Gamma - Hexachlorocyolohexane (Lindane)                                                                            0,05 Guthlon                                                                                                            0.10 Heptachlor                                                                                                          0.05 Heptachlor Epoxide                                                                                                  1,0 Hexachlorophene                                                                                                      10 Malathlon                                                                                                          0.10 Methoxychlor                                                                                                        2.0 Mirex                                                                                                                0.2 Parathion                                                                                                            0.1 Toxaphene                                                                                                             5 2,4,5-TP (SIlvex)                                                                                                    2
* Indicate trnits if different from mg/L.
TCEQ-10055 (05/15/2012) Industrial Wastewater Permit Application Technical Report                      Page 19 of 66


5 2,4,5-TP (SIlvex) 2* Indicate trnits if different from mg/L.TCEQ-10055 (05/15/2012)
Attachment NOC-AE-14003142 Page 53 of 155 Complete table required for all external outfalls. Not required for internal outfalls.
Industrial Wastewater Permit Application Technical Report Page 19 of 66 Attachment NOC-AE-14003142 Page 53 of 155 Complete table required for all external outfalls.
(Instructions, Page 52)
Not required for internal outfalls.(Instructions, Page 52)OUtfaII No' : nC oiG B616eIIVd b'ICOGn-, , Verage Mtaxlrimum NOf oSafibe&sect;Bromide Color(PCU)
OUtfaII No':               nC oiG           B616eIIVd     b'ICOGn
Nitrate-Nttrite(as N)Sulfide(as S)Sulfite(as SO 3)Surfactants Total Antimony Total Beryllium Total Boron Total Cobalt Total Iron Total Magnesium Total Molybdenum Total Manganese Total Thallium Total Tin Total Titanium TCEQ-10055.  
                                                      -             ,         , Verage Mtaxlrimum   NOf oSafibe&sect; Bromide Color(PCU)
(05/15/2012)
Nitrate-Nttrite(as N)
Industrial Wastewater PermIt Application Technical Report Page 20 of 66 Attachment NOC-AE-14003142 Page 54 of 155 Indicate with a check mark any of the industrial caategories applicable t o y our facility.
Sulfide(as S)
If testing is required, indicate with a check mark in the box provided that the testing results for the appropriate parameters in Table B-7 a re p rovided with t he application. (Instructions, Page 52-53)N/Ak .CiA ,etl4~dle Volatile Acid Oase/Neutral Pesticides Adhesives and Sealants Yes [] Yes El Yes El No Aluminum Forming Yes El Yes ED Yes El No Auto and Other Laundries Yes El Yes E) Yes El Yes El Battery Manufacturing Yes E] No Yes El No Coal Mining No No No No Coll Coating Yes D Yes El Yes El No Copper Forming Yes C- Yes El Yes El No__ Electric and Electronic Components Yes El Yes El Yes El Yes El Electroplating Yes Dl Yes El Yes El No Explosives Manufacturing No Yes El Yes El No Foundries Yes El Yes ED Yes El No Gum and Wood Chemicals_____Subparts AB,C,E Yes El Yes El No No Subparts D,F Yes El Yes Ul Yes El No Inorganic Chemicals Yes [l Yes El Yes [ No Iron and Steel Manufacturing Yes El Yes El Yes El No Leather Tanning/Finishing Yes El Yes El Yes El No Mechanical Products Manufacturing Yes El Yes El Yes El No__ Nonferrous Metals Mfg. Yes El Yes El Yes El Yes El Ore Mining(Subpart B) No Yes El No No Organic Chemicals, Plastics, and Synthetic Fibers Yes El Yea El Yes LJ Yes El Paint and Ink Formulation Yes El Yes El Yes El No Pesticides Yes El Yes El Yes El Yes D Petroleum Refining Yes El No No No Pharmaceutical Preparations Yes El Yes El Yes EL No Photographic Equipment and Supplies Yes El Yes El Yes El No Plastic and Synthetic Materials Manufacturing Yes El Yes El Yes El Yes El Plastic Processing Yes El No No No Porcelain Enameling No No No No Printing and Publishing Yes El Yes El Yes El Yes El-Pulp and Paperboard Mills___.Subparts A *E ] Yes l *l Yes U_ Subparts B, C, D, R
Sulfite(as SO3)
* El Yes l *El *El____Subparts F, G, H, 1, K, L, M. N, O, P Yes El Yes El
Surfactants Total Antimony Total Beryllium Total Boron Total Cobalt Total Iron Total Magnesium Total Molybdenum Total Manganese Total Thallium Total Tin Total Titanium TCEQ-10055. (05/15/2012) Industrial Wastewater PermIt Application Technical Report               Page 20 of 66
 
Attachment NOC-AE-14003142 Page 54 of 155 Indicate with a check mark any of the industrial caategories applicable t o y our facility. If testing is required, indicate with a check mark in the box provided that the testing results for the appropriate parameters in Table B-7 a re p rovided with t he application. (Instructions, Page 52-53)
N/Ak,etl4~dle   .                                                              CiA Volatile       Acid       Oase/Neutral   Pesticides Adhesives and Sealants                                     Yes []         Yes El     Yes El         No Aluminum Forming                                           Yes   El       Yes   ED   Yes El       No Auto and Other Laundries                                   Yes   El       Yes   E)   Yes El       Yes El Battery Manufacturing                                     Yes   E]       No         Yes El       No Coal Mining                                               No             No         No             No Coll Coating                                               Yes   D         Yes   El   Yes El       No Copper Forming                                             Yes   C-       Yes   El   Yes El       No
__  Electric and Electronic Components                         Yes   El       Yes   El   Yes El       Yes El Electroplating                                             Yes   Dl       Yes   El   Yes El       No Explosives Manufacturing                                   No             Yes   El   Yes El       No Foundries                                                 Yes   El       Yes   ED   Yes El       No Gum and Wood Chemicals
_____Subparts AB,C,E                                     Yes El         Yes El     No             No Subparts D,F                                 Yes El         Yes Ul     Yes El         No Inorganic Chemicals                                       Yes [l         Yes El     Yes [         No Iron and Steel Manufacturing                               Yes El         Yes El     Yes El       No Leather Tanning/Finishing                                 Yes El         Yes El     Yes El       No Mechanical Products Manufacturing                         Yes El         Yes El     Yes El       No
__      Nonferrous Metals Mfg.                                     Yes El         Yes El     Yes El       Yes El Ore Mining(Subpart B)                                     No             Yes El     No             No Organic Chemicals, Plastics, and Synthetic Fibers         Yes El         Yea El     Yes LJ       Yes El Paint and Ink Formulation                                 Yes El         Yes El     Yes El       No Pesticides                                                 Yes El         Yes El     Yes El       Yes D Petroleum Refining                                         Yes El           No         No             No Pharmaceutical Preparations                               Yes El         Yes El     Yes   EL       No Photographic Equipment and Supplies                       Yes El         Yes El     Yes   El       No Plastic and Synthetic Materials Manufacturing             Yes El         Yes El     Yes   El       Yes El Plastic Processing                                         Yes El           No         No             No Porcelain Enameling                                       No               No         No             No Printing and Publishing                                   Yes El           Yes El     Yes   El       Yes El
    -Pulp       and Paperboard Mills
___.Subparts A                                           *E]             Yes     l *l             Yes U
_          Subparts B, C, D, R
* El           Yes     l *El           *El
____Subparts F, G, H, 1, K, L, M. N,O, P                 Yes El         Yes   El
* El
* El
* El Subparts E, Q, S, T Yes El Yes l *El Yes [Subparts J, U YesEl Yes El Yes El
* El Subparts E, Q, S, T                           Yes El         Yes     l *El           Yes [
* El-Rubber Processing Yes El Yes El Yes El No Soap and Detergent Manufacturing Yes El Yes El Yes El No V Steam Electric Power Plants Yes El Yes El No No Textile Mills (Not Subpart C). Yes El Yes El Yes El No Timber Products Processing Yes El Yes El Yes El Yes El* Test if "believed present" TCEQ-10055 (05116/2012)
Subparts J, U                                 YesEl           Yes   El   Yes El
Industrial Wastewater Permit Application Technical Report Page 21 of 66 Attachment NOC-AE-14003142 Page 55 of 155 Please complete as directed and only for those parameters specified in Table 6 Required for all external outfalls which contain process wastewater.
* El
N ot required for internal outfalls.
    -Rubber         Processing                                   Yes El         Yes   El   Yes El         No Soap and Detergent Manufacturing                           Yes El         Yes   El   Yes El         No V Steam Electric Power Plants                                   Yes El         Yes   El   No             No Textile Mills (Not Subpart C).                             Yes El         Yes   El Yes El         No Timber Products Processing                                 Yes El         Yes   El Yes El         Yes El
Testing may be required for types of industry not specified in Table 6 for specific parameters if believed present (Instructions, Page 53).TAIILE t... ,. ., ..} .,:. ..
* Test if "believed present" TCEQ-10055 (05116/2012) Industrial Wastewater Permit Application Technical Report                       Page 21 of 66
'.. ' : !,: 7 ' , L' ~ '* llll lrR ll ll, llrl;" .. .. ... ..,.{. ., ., .:...i, .... ,. ..i .*ll ., i ..,.. ,... ..:...,,.SS VOLATIlLE COMPOUNDS, ', ~pp Acrolein 50 Acrylonltrile 50 Benzene 10 Bromoform 10 Carbon Tetrachloride 10 Chlorobenzene 10 Chlorodibromomethane 10 Chloroethane 50 2-Chloroethylvinyl Ether 10 Chloroform 10 Dichlorobromomethane 10 1,1-Dlchloroethane 10 1,2-Dichloroethane 10 1,1-Dichloroethylene 10 1,2-Dichloropropane 10 1,3-Dlchloropropylene 10 Ethylbenzene 10 Methyl Bromide 50 Methyl Chloride 50 Methylene Chloride 20 1,1,2,2-Tetrachloroethane 10 Tetrachloroethylene 10 Toluene 10 1,2-Trans-Dlchloroethylene 10 1,11,11-TrIchloroethane 10 1,1,2-Trichloroethane 10 Trichloroethylene 10 Vinyl Chloride 10 TCEQ-1 0055 (05/16/2012)
 
Industrial Wastewater Permit Application Technical Report Page 22 of 66 Attachment NOC-AE-14003142 Page 56 of 155 Effluent Concentration (pg/I)*Average Maximum MAL (pg/o)' -. I-Samples ACID COMPOUNDS V 2-Chlorophenol 10 2 , 4-Dlchlorophenol 10 2,4-Dimethylphenol 10 4,6-Dinltro-o-Cresol 50 2,4-Dinitrophenol 50 2-Nitrophenol 20 4-Nitrophenol 50 P-Chloro-m-Cresol 10 Pentalchlorophenol 50 Phenol 10 2,4,6-Trichlorophenol 10 BASEINEUTRAL COMPOUNDS Acenaphthene 10 Acenaphthylene 10 Anthracene 10 Benzldine 50 Benzo(a)Anthracene 10 Benzo(a)Pyrene 10 3,4-Benzofluoranthene 10 Benzo(ghl)Perylene 20 Benzo(k)Fluo.ranthene 10 Bis(2-Chloroethoxy)
Attachment NOC-AE-14003142 Page 55 of 155 Please complete as directed and only for those parameters specified in Table 6 Required for all external outfalls which contain process wastewater. N ot required for internal outfalls. Testing may be required for types of industry not specified in Table 6 for specific parameters if believed present (Instructions, Page 53).
Me~thane 10 Bis(2-Chloroethyl)Eter  
TAIILE     t
..10 B.s(2-Chlorolsopropyl).Eth~er 10 Bis(2-Ethylhexyl)Phthlarte 1.0 4-Bromophenyl Phenyl Ether 10 Butylbenzyl Phthalate 10 2-chloronaphthalene 10 4-chorophenyl phenyl ether 10 Chrysene 10 Dlbenzo(a,h)Anthracene 20 1.,2-Dlchlorobenzene 10 1,3_.Dchlorbenzene 10 1,4-Dlchlorobenzene 10 3,3-Dlchlorobenzldine 50 Dl~ethyl Phthalate 110 Dlmethyl Phthalate 10 DI-n-Butyl Phthalate 10 2,4-Dlnitrotoluene 10 2,6-Dinltroluene 10 DI-n-Octyl Phthalate 10 TCEQ-1 0055 (05115/2012)
* llll lrR ll
Industrial Wastewater Permit Application Technical Report Page 23 of 66 Attachment NOC-AE-14003142 Page 57 of 155
:. ..****:.i,::'':.H ll,llrl;" .. ..
:.
                              ... ..,.{. .,
nt Concentration (pgll)*  
                                                          . .,. :*'!,:r'* :*,:!'~ * : !,:
: Pollutants Average Maximum !No. of Samples MAL (pg/I)BASEINEUTRAL COMPOUNDS (cont.)
* 7 *.::
1,2-Dlphenyl Hydrazine (as Azobenzene) 20 Fluoranthene 1'0 Fluorene 10 Hexachlarobenzene 10 Hexachlorobutadiene 10 Hexachlorocyclopentadlene 10 Hexachloroethane 20 Indeno(1,2,3-cd)pyrene 20 Isophorone 10 Naphthalene 10 Nitrobenzene 10 N-Nltrosodlmethylamlne 50 N-Nitrosodl-n-Propylamlne 20 N-Nitrosodiphenylamlne 20.Phenanthrehe 10 Pyrene 10 1,2,4-Trichlorobe nzene 10 PESTICIDES Aldrin 0.05 alpha-BHC 0.05 beta-BHC 0.05 gamma-BHC 0.05 delta-BHC 0,05 Chlordane 0.15 4,4-DDT 0.1 4,4-DDE 0.1 Dleldrin 0.1 alpha-Endosulfan 0.1 beta-Endosulfan 0,1 Endosulfan Sulfate 0,1 Endrln 0.1 Endrln Aldehyde 0.1 Heptachlor 0.05 Heptachlor Epoxide PCB-1 264 1.0 PCB-1 221 1.0 PCB-1242 PCB-1 232 1,0 PCB-1248 1.0 PCB-1 260 1.0 PCB-1016 1.0 Toxaphene 5.0....... .... ...I M, , ... .. .-.. ... ......, , .TCEQ-1 0055 (05/15/2012)
                                            ., .:...i, ....     ,. . .i .*ll *    . , i .. il*]i ,.. ,... .. :...,,.
Industrial Wastewater Permit Application Technical Report Page 24 of 66 Attachment NOC-AE-14003142 Page 58 of 155 8 TABL3 IS (MOXINS/ RA WOiUDS Please complete as directed.
                                                                                                                      -*,*          L' .vg.*.}
Not required for internal outfalls. (Instructions, Pages 53-54)a. Are any of the following compounds manufactured and/or u sed in a process at t he facility?
                                                                                                                                    ,          ,* ~ * * . ,      W-w* ''
Fj Yes 0 No If yes, i ndicate with a ch eck mark the compound(s) which apply and provide a brief description of the conditions of its/their presence at the facility.Ml 2,4,5-trichlorophenoxy acetic acid (2,4,5-T)
SS VOLATIlLE COMPOUNDS,                                                           ',                                                 ~pp Acrolein                                                                                                                                                       50 Acrylonltrile                                                                                                                                                   50 Benzene                                                                                                                                                         10 Bromoform                                                                                                                                                       10 Carbon Tetrachloride                                                                                                                                           10 Chlorobenzene                                                                                                                                                   10 Chlorodibromomethane                                                                                                                                           10 Chloroethane                                                                                                                                                   50 2-Chloroethylvinyl Ether                                                                                                                                       10 Chloroform                                                                                                                                                     10 Dichlorobromomethane                                                                                                                                           10 1,1-Dlchloroethane                                                                                                                                             10 1,2-Dichloroethane                                                                                                                                             10 1,1-Dichloroethylene                                                                                                                                           10 1,2-Dichloropropane                                                                                                                                           10 1,3-Dlchloropropylene                                                                                                                                         10 Ethylbenzene                                                                                                                                                   10 Methyl Bromide                                                                                                                                                 50 Methyl Chloride                                                                                                                                               50 Methylene Chloride                                                                                                                                             20 1,1,2,2-Tetrachloroethane                                                                                                                                     10 Tetrachloroethylene                                                                                                                                           10 Toluene                                                                                                                                                       10 1,2-Trans-Dlchloroethylene                                                                                                                                     10 1,11,11-TrIchloroethane                                                                                                                                       10 1,1,2-Trichloroethane                                                                                                                                         10 Trichloroethylene                                                                                                                                             10 Vinyl Chloride                                                                                                                                                 10 TCEQ-1 0055 (05/16/2012) Industrial Wastewater Permit Application Technical Report                                                                     Page 22 of 66
CAS #93-76-5 E- 2-(2,4,5-trichlorophenoxy) propanoic acid (Silvex, 2,4,5-TP)
 
CAS #93-72-1 n- 2-(2,4,5-trichlorophenoxy) ethyl 2,2-dichloropropionate (Erbon) CAS #136-25-4[] o,o-dimethyl o-(2,4,5-trichlorophenyl) phosphorothioate (Ronnel) CAS #P-99-84-3 E] 2,4,5-trichlorophenol (TCP) CAS #95-95-4 E] Hexachlorophene (HCP) CAS #70-30-4 b. Do you know or have any reason to believe that 2,3,7,8 Te trachlorodibenzo-P-Dioxin (TCDD) or any congeners of TCDD may be present in your effluent?
Attachment NOC-AE-14003142 Page 56 of 155 Effluent Concentration (pg/I)*
[] Yes [] No If yes, provide a brief description of the conditions for its presence.C.If your responded yes to either item a or b, complete Table 8 as instructed.
ACID COMPOUNDS S-!.*;- .,*        ' -.
VAB TE 8 Outfall No. -C [G u:7 ,wte.'':EMIulvent Concentration EqivalV~ents Concelitratiori EqUlValentSt MAL (ppq)_onip6Und QA&#xfd;&#xfd;rs~~(p)
Average I-Samples Maximum V
..P? (PptM (ppt))2,3,7,8-TCDD 1 10.0 1,2,3,7,8-PeCDD 0.5 50.0 2,3,7,8-HxCDDs 0.1 50.0 2,3,7,8-TCDF 0.1 10.0 1,2,3,7,8-PeCDF 0.05 50.0 2,3,4,7,8-PeCDF 0,5 50.0 2,3,7,8-HxCDFs 0.1 50.0 Total TCEQ-1 0055 (05115/2012)
MAL (pg/o) 2-Chlorophenol                                                                               10 2 ,4-Dlchlorophenol                                                                           10 2,4-Dimethylphenol                                                                           10 4,6-Dinltro-o-Cresol                                                                         50 2,4-Dinitrophenol                                                                             50 2-Nitrophenol                                                                                 20 4-Nitrophenol                                                                                 50 P-Chloro-m-Cresol                                                                             10 Pentalchlorophenol                                                                           50 Phenol                                                                                       10 2,4,6-Trichlorophenol                                                                         10 BASEINEUTRAL COMPOUNDS Acenaphthene                                                                                 10 Acenaphthylene                                                                               10 Anthracene                                                                                   10 Benzldine                                                                                     50 Benzo(a)Anthracene                                                                           10 Benzo(a)Pyrene                                                                               10 3,4-Benzofluoranthene                                                                         10 Benzo(ghl)Perylene                                                                           20 Benzo(k)Fluo.ranthene                                                                         10 Bis(2-Chloroethoxy) Me~thane                                                                 10 Bis(2-Chloroethyl)Eter ..                                                                     10 B.s(2-Chlorolsopropyl).Eth~er                                                                 10 Bis(2-Ethylhexyl)Phthlarte                                                                   1.0 4-Bromophenyl Phenyl Ether                                                                   10 Butylbenzyl Phthalate                                                                         10 2-chloronaphthalene                                                                           10 4-chorophenyl phenyl ether                                                                   10 Chrysene                                                                                     10 Dlbenzo(a,h)Anthracene                                                                       20 1.,2-Dlchlorobenzene                                                                         10 1,3_.Dchlorbenzene                                                                           10 1,4-Dlchlorobenzene                                                                         10 3,3-Dlchlorobenzldine                                                                         50 Dl~ethyl Phthalate                                                                             110 Dlmethyl Phthalate                                                                             10 DI-n-Butyl Phthalate                                                                           10 2,4-Dlnitrotoluene                                                                             10 2,6-Dinltroluene                                                                               10 DI-n-Octyl Phthalate                                                                           10 TCEQ-1 0055 (05115/2012) Industrial Wastewater Permit Application Technical Report       Page 23 of 66
Industrial Wastewater Permit Application Technical Report Page 26 of 66 Attachment NOC-AE-14003142 Page 59 of 155~9.J'flJE9HAAt V1J S STAN~ES: Proceed complete as directed.
 
Not required for internal outfalls. (Instructions, Pages 55)a. Are there any pollutants listed In the instructions (page 55) believed present in the discharge?
Attachment NOC-AE-14003142 Page 57 of 155
LlYes INo b. Are there pollutants listed in Item No. i.d. on Page No. i of this technical report which are believed present in the discharge and have not been analytically quantified elsewhere in this application?
                      *, * ,,*,,* ,**.,*,*,{,,_*
[]Yes O7No If your responded yes to either item, complete Table 9 as instructed.
                                        ,#*.      :. *. .*:,Efflue          nt Concentration (pgll)*           *:,i"!;:;.*'i:;!**        :
TALit<~Arae 0px~niiI 'N6. of, 1'Atialytio~I
Pollutants                                                   Average       Maximum         !No. of Samples       MAL (pg/I)
_______________________________
BASEINEUTRAL COMPOUNDS (cont.)                                     !***l**;*********-i;*LI      **i  ******;L**
CAS-N_________d_________
NTi*:i            *,,,';:'''****'.
1- 4 4-I 4- 4 4 t .4- 4 .4 I *4-* .4 4-t +/- 4 +TCEQ-1 0055 (05/1512012)
1,2-Dlphenyl Hydrazine (as Azobenzene)                                                                                   20 Fluoranthene                                                                                                             1'0 Fluorene                                                                                                                 10 Hexachlarobenzene                                                                                                         10 Hexachlorobutadiene                                                                                                       10 Hexachlorocyclopentadlene                                                                                                 10 Hexachloroethane                                                                                                         20 Indeno(1,2,3-cd)pyrene                                                                                                   20 Isophorone                                                                                                                 10 Naphthalene                                                                                                               10 Nitrobenzene                                                                                                               10 N-Nltrosodlmethylamlne                                                                                                   50 N-Nitrosodl-n-Propylamlne                                                                                                 20 N-Nitrosodiphenylamlne                                                                                                   20.
Industrial Wastewater Permit Application Technical Report Page 26 of 66 Attachment NOC-AE-14003142 Page 60 of 155 Worksheet
Phenanthrehe                                                                                                             10 Pyrene                                                                                                                   10 1,2,4-Trichlorobe nzene                                                                                                   10 PESTICIDES Aldrin                                                                                                                   0.05 alpha-BHC                                                                                                               0.05 beta-BHC                                                                                                                 0.05 gamma-BHC                                                                                                               0.05 delta-BHC                                                                                                               0,05 Chlordane                                                                                                               0.15 4,4-DDT                                                                                                                   0.1 4,4-DDE                                                                                                                   0.1 Dleldrin                                                                                                                 0.1 alpha-Endosulfan                                                                                                         0.1 beta-Endosulfan                                                                                                           0,1 Endosulfan Sulfate                                                                                                       0,1 Endrln                                                                                                                   0.1 Endrln Aldehyde                                                                                                           0.1 Heptachlor                                                                                                               0.05 Heptachlor Epoxide PCB-1 264                                                                                                                 1.0 PCB-1 221                                                                                                                 1.0 PCB-1242 PCB-1 232                                                                                                                 1,0 PCB-1248                                                                                                                 1.0 PCB-1 260                                                                                                               1.0 PCB-1016                                                                                                                 1.0 Toxaphene                                                                                                                 5.0
....... ..... . .I, . .. .. . - .. . .. . .     . . . .,M,                  , .
TCEQ-1 0055 (05/15/2012) Industrial Wastewater Permit Application Technical Report                     Page 24 of 66


===4.0 Receiving===
Attachment NOC-AE-14003142 Page 58 of 155 8 TABL3 IS (MOXINS/ WOiUDS              RA Please complete as directed. Not required for internal outfalls. (Instructions, Pages 53-54)
: a. Are any of the following compounds manufactured and/or u sed in a process at t he facility?            Fj Yes          0 No If yes, i ndicate with a ch eck mark the compound(s) which apply and provide a brief description of the conditions of its/their presence at the facility.
Ml    2,4,5-trichlorophenoxy acetic acid (2,4,5-T) CAS #93-76-5 E- 2-(2,4,5-trichlorophenoxy) propanoic acid (Silvex, 2,4,5-TP) CAS #93-72-1 n- 2-(2,4,5-trichlorophenoxy) ethyl 2,2-dichloropropionate (Erbon) CAS #136-25-4
[] o,o-dimethyl o-(2,4,5-trichlorophenyl) phosphorothioate (Ronnel) CAS #P-99-84-3 E] 2,4,5-trichlorophenol (TCP) CAS #95-95-4 E] Hexachlorophene (HCP) CAS #70-30-4
: b. Do you know or have any reason to believe that 2,3,7,8 Te trachlorodibenzo-P-Dioxin (TCDD) or any congeners of TCDD may be present in your effluent?                                        [] Yes [] No If yes, provide a brief description of the conditions for its presence.
C. If your responded yes to either item a or b, complete Table 8 as instructed.
VAB TE 8 Outfall No.            -C    [G                ,wte.                                          u:7
          '':EMIulvent                  Concentration      EqivalV~ents      Concelitratiori    EqUlValentSt      MAL (ppq)
_onip6Und                    QA&#xfd;&#xfd;rs~~(p)                    .. (PptM P?                                    (ppt))
2,3,7,8-TCDD                1                                                                                          10.0 1,2,3,7,8-PeCDD            0.5                                                                                          50.0 2,3,7,8-HxCDDs            0.1                                                                                          50.0 2,3,7,8-TCDF              0.1                                                                                          10.0 1,2,3,7,8-PeCDF          0.05                                                                                          50.0 2,3,4,7,8-PeCDF            0,5                                                                                          50.0 2,3,7,8-HxCDFs            0.1                                                                                          50.0 Total TCEQ-1 0055 (05115/2012) Industrial Wastewater Permit Application Technical Report                            Page 26 of 66


Waters Attachment NOC-AE-14003142 Page 61 of 155 WORKSHEET
Attachment NOC-AE-14003142 Page 59 of 155
    ~9.J'flJE9HAAt                            S V1J STAN~ES:
Proceed complete as directed. Not required for internal outfalls. (Instructions, Pages 55)
: a. Are there any pollutants listed In the instructions (page 55) believed present in the discharge?
LlYes      INo
: b. Are there pollutants listed in Item No. i.d. on Page No. i of this technical report which are believed present in the discharge and have not been analytically quantified elsewhere in this application?
[]Yes      O7No If your responded yes to either item, complete Table 9 as instructed.
TALit CAS-N_________d_________
                                                                        <~Arae0px~niiI    'N6.of,  1'Atialytio~I 1-        4          4
                                            -            I                  4-      4          4 t                  .4-      4          .4 I                  *4-*    .4          4-t                  +/-        4          +
TCEQ-1 0055 (05/1512012) Industrial Wastewater Permit Application Technical Report                Page 26 of 66


===4.0 RECEIVING===
Attachment NOC-AE-14003142 Page 60 of 155 Worksheet 4.0 Receiving Waters


WATERS THE FOLLOWING IS REQUIRED FOR ALL TPDES PERMIT APPLICATIONS Is t here a surface water intake for domestic drinking water supply I ocated within 5 (five) miles downstream from the point/proposed point of discharge?
Attachment NOC-AE-14003142 Page 61 of 155 WORKSHEET 4.0 RECEIVING WATERS THE FOLLOWING IS REQUIRED FOR ALL TPDES PERMIT APPLICATIONS Is t here a surface water intake for domestic drinking water supply I ocated within 5 (five) miles downstream from the point/proposed point of discharge?
ElYes WNo If yes, identify owner of the drinking water supply, the distance and direction to the Intake, and locate and identify the intake on the USGS map. Indicate by a check mark that the requested information is provided:
ElYes       WNo If yes, identify owner of the drinking water supply, the distance and direction to the Intake, and locate and identify the intake on the USGS map. Indicate by a check mark that the requested information is provided: D]
D]a. Width of the receiving water at the outfall? ~300 feet b. Are there oyster reefs in the vicinity of the discharge?  
: a. Width of the receiving water at the outfall?                         ~300       feet
[] Yes [No If yes, Indicate approximate distance and direction from outfall(s):
: b. Are there oyster reefs in the vicinity of the discharge?                     [] Yes   [No If yes, Indicate approximate distance and direction from outfall(s):
: c. Are there any sea grasses within the vicinity of the point of discharge?
: c. Are there any sea grasses within the vicinity of the point of discharge?
D Yes []No If yes, provide the distance and direction to the grasses: Is the discharge directly into (or within 300 feet of) a classified segment?V Yes -No If yes , stop here. It is not necessary to complete items 4 and 5 and it is n ot necessary to complete Worksheet 2.1. If no, complete items 4 and 5.Name of the immediate receiving waters: a. Check the appropriate description of the receiving waters H Man-made Channel or Ditch E Stream or creek n] Lake or Pond Surface area _ .acres Average depth of the entire water body -feet Average depth of water body within a 5oo-foot radius or the discharge point -feet E] Freshwater Swamp or Marsh T idal Stream, Bayou, or Marsh Open Bay[] Other: If a man-made channel, ditch or stream was checked above, provide the following:
D Yes []No If yes, provide the distance and direction to the grasses:
TCEQ-10055 (05/1612012)
Is the discharge directly into (or within 300 feet of) a classified segment?
Industrial Wastewater Permit Application Technical Report Page 39 of 66 Attachment NOC-AE-14003142 Page 62 of 155 b. Check one of the following that best characterizes the area upstream of the discharge.
V Yes         -No If yes , stop here. It is not necessary to complete items 4 and 5 and it is n ot necessary to complete Worksheet 2.1. If no, complete items 4 and 5.
For new discharges, characterize the area downstream of the discharge (check one).-' Intermittent (dry for at least one week during most years)L] Intermittent with Perennial Pools (enduring p ools c ontaining s ufficlent habitat t o maintain significant aquatic life uses)F] Perennial (normally flowing)Check t he method used t o c haracterize t he a rea u pstream (or d ownstream for n ew dischargers):
Name of the immediate receiving waters:
: a. Check the appropriate description of the receiving waters H Man-made Channel or Ditch EStream or creek n] Lake or Pond Surface area             _     .acres Average depth of the entire water body                     - feet Average depth of water body within a 5oo-foot radius or the discharge point                 -     feet E] Freshwater Swamp or Marsh Tidal Stream, Bayou, or Marsh Open Bay
[] Other:
If a man-made channel, ditch or stream was checked above, provide the following:
TCEQ-10055 (05/1612012) Industrial Wastewater Permit Application Technical Report               Page 39 of 66
 
Attachment NOC-AE-14003142 Page 62 of 155
: b. Check one of the following that best characterizes the area upstream of the discharge.
For new discharges, characterize the area downstream of the discharge (check one).
        -' Intermittent (dry for at least one week during most years)
L] Intermittent with Perennial Pools (enduring p ools c ontaining s ufficlent habitat t o maintain significant aquatic life uses)
F] Perennial (normally flowing)
Check t he method used t o c haracterize t he a rea u pstream (or d ownstream for n ew dischargers):
FI USGS flow records DI personal observation LI historical observation by adjacent landowner(s)
FI USGS flow records DI personal observation LI historical observation by adjacent landowner(s)
[] others, specify: C. List t he n ame(s) o f all p erennial streams t hat j oin t he r eceiving water within three miles downstream of the discharge point: d. Do the receiving water characteristics change within three miles downstream of t he discharge? (e.g., natural or man-made dams, ponds, reservoirs, etc Dl Yes E]No If yes, discuss how: e. Provide general obser vations of the water body during normal dry weather conditions:
[] others, specify:
C. List t he n ame(s) o f all p erennial streams t hat j oin t he r eceiving water within three miles downstream of the discharge point:
: d. Do the receiving water characteristics change within three miles downstream of t he discharge? (e.g., natural or man-made dams, ponds, reservoirs, etc Dl Yes E]No If yes, discuss how:
: e. Provide general obser vations of the water body during normal dry weather conditions:
Date and time of observation:
Date and time of observation:
Was water body influenced by stormwater runoff during observations?
Was water body influenced by stormwater runoff during observations?
n Yes [-No a. Is the receiving water upstream of the discharges or proposed discharge site influenced by (check as appropriate):
n Yes [-No
RI oil field activities LI urban runoff L-] agricultural runoff LI septic tanks E] upstream discharges LI others, specify below TCEQ-10055 (05/115/2012)
: a. Is the receiving water upstream of the discharges or proposed discharge site influenced by (check as appropriate):
Industrial Wastewater Permit Application Technical Report Page 40 of 66 Attachment NOC-AE-14003142 Page 63 of 155 b. Uses of water body observed or evidences of (check as appropriate):.
RI oil field activities                                               LI urban runoff L-] agricultural runoff                                               LI septic tanks E] upstream discharges                                                 LI others, specify below TCEQ-10055 (05/115/2012) Industrial Wastewater Permit Application Technical Report                   Page 40 of 66
[ livestock watering El contact recreation ED irrigation withdrawal Li non contact recreation El fishing E- navigation El domestic water supply Li industrial water supply Ri picnic park activities El others, specify below c. Check one of the following to best describe the aesthetics of the receiving water and the surrounding area: LI Wilderness:
outstanding natural beauty; usually wooded or unpastured area: water clarity exceptional Li Natural Area: trees and/or native vegetation common; some development evident (from fields, pastures,dwellings);
water clarity discolored Li Common Setting: not offensive, developed but uncluttered; water may be colored or turbid Li Offensive:
stream does not enhance aesthetics; cluttered; highly developed; dumping areas; water discolored TCEQ-10055 (0511512012)
Industrial Wastewater Permit Application Technical Report Page 41 of 66 Attachment NOC-AE-14003142 Page 64 of 155 Worksheet


===5.0 Sewage===
Attachment NOC-AE-14003142 Page 63 of 155
Sludge Management and Disposal Attachment NOC-AE-14003142 Page 65 of 155 WORKSHEET 5.o SEWAGE SLUDGE MANAGEMENT AND DISPOSAL THE FO ILOWING I S R EQUIRED FO R A LL T PDES PER MIT A PPLICATIONS THAT M EET T HE CONDITIONS AS OUTLINED I N T ECHNICAL REPORT 1.o, ITEM NO. 7.a. Is this a new permit application or an amendment permit application?
: b. Uses of water body observed or evidences of (check as appropriate):.
0 Yes E] No *The amendment requests will not change the sludge handling process at the facility.b. Does the facility discharge in the Lake Houston watershed?
[ livestock watering                          El contact recreation          ED irrigation withdrawal Li non contact recreation                    El fishing                      E- navigation El domestic water supply                      Li industrial water supply Ri picnic park activities El others, specify below
R Yes 0 No If yes to either item a or b, Indicate by a check mark that a solids management plan was provided with the application.
: c. Check one of the following to best describe the aesthetics of the receiving water and the surrounding area:
E-] N/A, see note above.NAiL P 4AE~~~A4 QA~(ntcl;~e 4).a. Please check t he current sludge disposal m ethod(s).
LI  Wilderness: outstanding natural beauty; usually wooded or unpastured area: water clarity exceptional Li  Natural Area: trees and/or native vegetation common; some development evident (from fields, pastures,dwellings); water clarity discolored Li  Common Setting: not offensive, developed but uncluttered; water may be colored or turbid Li  Offensive: stream does not enhance aesthetics; cluttered; highly developed; dumping areas; water discolored TCEQ-10055 (0511512012) Industrial Wastewater Permit Application Technical Report               Page 41 of 66
More t han one method can b e checked.[] Permitted landfill[] Marketing and distribution by the permittee-- Registered land application site n-] Composted by the permittee[ Surface disposal site (sludge monofill)D Transported to another WWTP (written statement or contractual agreement required)[] Beneficial land application as authorized in the existing permit b. Disposal site name: Blue Ridge Landfill, TCEQ Permit/Registration Number: 1505 County where disposal site is located: Fort Bend County C. Method of Transportation (truck, train, pipe, other): Truck Hauler Registration Number: Aqua Zyme Services, Reg.. No. 21480 Transported in: FI liquid E semi-liquid F-1 semi-solid Z] solid state Land application for: EL Reclamation R Soil Conditioning
: d. If the existing permit contains authorization for sludge land application, composting, marketing and distribution of sludge, and/or sludge lagoons and authorization t o renew t he activity is being s ought in t he application, t he appropriate s ections o f t he Sludge Technical Report must be provided.TCEQ-1 0055 (05/15/2012)
Industrial Wastewater Permit Application Technical Report Page 45 of 66 Attachment NOC-AE-14003142 Page 66 of 155~~Ag S WJouA xMo S ~TD'GEPR'S-SOSAL A hcio '4s,7a~5~Are you requesting new authorization to beneficially land apply sewage sludge at this site or a site under your direct control?Mi Yes 0 No Are you requesting new authorization to market and distribute sewage sludge at this facility or a facility under your direct control?[] Yes W1 No Are you requesting new authorization to compost sewage sludge?[D1 Yes IZ No Are you requesting new authorization to surface dispose sewage sludge at this site or site under your direct control?M Yes IZ No Are you requesting new authorization t o in cinerate sewage sludge at t his site o r site under your direct control?ElYes WZINo If yes to any of the above it ems, provide the information required in the S LUDGE TECHNICAL REPORT.New authorization for beneficial land application, incineration, and sludge lagoons in the TPDES or TLAP permits requires a major a mendmentto t he p ermit. New authorization for composting may require a major amendment to the permit. See the instructions for an explanation whether a major amendment Is required or if authorization for composting can be added through the renewal process.TCEQ-1 0055 (05/15/2012)
Industrial Wastewater Permit Application Technical Report Page 46 of 66 Attachment NOC-AE-14003142 Page 67 of 155 Worksheet


===7.0 Storm===
Attachment NOC-AE-14003142 Page 64 of 155 Worksheet 5.0 Sewage Sludge Management and Disposal
Water Runoff Attachment NOC-AE-14003142 Page 68 of 155 WORICSHEET


===7.0 STORMWATER===
Attachment NOC-AE-14003142 Page 65 of 155 WORKSHEET 5.o SEWAGE SLUDGE MANAGEMENT AND DISPOSAL THE FO ILOWING I S R EQUIRED FO R A LL T PDES PER MIT A PPLICATIONS THAT M EET T HE CONDITIONS AS OUTLINED I N T ECHNICAL REPORT 1.o, ITEM NO. 7.
: a. Is this a new permit application or an amendment permit application?
0 Yes              E] No *The amendment requests will not change the sludge handling process at the facility.
: b. Does the facility discharge in the Lake Houston watershed?
R Yes              0 No If yes to either item a or b, Indicate by a check mark that a solids management plan was provided with the application. E-] N/A, see note above.
P            4AE~~~A4      NAiL                    QA~(ntcl;~e              4).
: a. Please check t he current sludge disposal m ethod(s). More t han one method can b e checked.
[]    Permitted landfill
[]    Marketing and distribution by the permittee
        --  Registered land application site n-]    Composted by the permittee
[    Surface disposal site (sludge monofill)
D Transported to another WWTP (written statement or contractual agreement required)
[] Beneficial land application as authorized in the existing permit
: b. Disposal site name:            Blue Ridge Landfill, TCEQ Permit/Registration Number: 1505 County where disposal site is located: Fort Bend County C. Method of Transportation (truck, train, pipe, other): Truck Hauler Registration Number: Aqua Zyme Services, Reg.. No. 21480 Transported in:              FI liquid        E semi-liquid              F-1 semi-solid  Z] solid state Land application for:                EL  Reclamation            R Soil Conditioning
: d.      If the existing permit contains authorization for sludge land application, composting, marketing and distribution of sludge, and/or sludge lagoons and authorization t o renew t he activity is being s ought in t he application, t he appropriate s ections o f t he Sludge Technical Report must be provided.
TCEQ-1 0055 (05/15/2012) Industrial Wastewater Permit Application Technical Report                Page 45 of 66


RUNOFF WORIKSHEET REQUIRED FOR ALL TPDES PERMIT APPLICATIONS APPLYING FOR INDIVIDUAL PERMIT COVERAGE FOR DISCHARGES OF STORM WATER RUNOFF.1. Do discharges from a ny of the p roposed or e xisting outfalls consist of stormw ater runoff only o r s tormwater runoff and any of the l isted n on-stormwater discharges?(See Instructions, Page 79)W-Yes IZINo If yes, proceed as directed.
Attachment NOC-AE-14003142 Page 66 of 155 WJouA xMo S ~~Ag                                      S
If no, stop here.2. Indicate by a check mark which type of authorization covers or is proposed to cover discharges from each stormwater outfall. (See Instructions, Page 79)outfallI coverage Coverqag U'nde .r oulI coverbkoe coverage Under-UdrMGP Indiv"idual.
                                                                                ~TD'GEPR'S-  SOSAL A    hcio            '4s,7a~5~
Permit utar Under MSGI' In'dividual Pelrnit&#xfd;
Are you requesting new authorization to beneficially land apply sewage sludge at this site or a site under your direct control?
:. ...., u a.... .. ....,-4. 4. .11 4 L 4 -4* -II -I-J. .11 A -L If you have indicated that all existing or proposed stormwater outfalls are covered under the MSGP, stop here. If you have indicated that you are seeking authorization under an individual permit, proceed as directed.TH OU~0* GVrM ARE !EQ.~~)F R ]IAC obTFAtlHA.  
Mi Yes            0 No Are you requesting new authorization to market and distribute sewage sludge at this facility or a facility under your direct control?
..DISCH GES StOIMWATERANDT OR WT6IIfY`OtJARESEEKICN(~N W&#xfd;MALftTO1UZATON UNDER MlIfS PERMIT APPLICATION.
[] Yes            W1 No Are you requesting new authorization to compost sewage sludge?
[D1 Yes          IZ No Are you requesting new authorization to surface dispose sewage sludge at this site or site under your direct control?
M Yes            IZ No Are you requesting new authorization t o in cinerate sewage sludge at t his site o r site under your direct control?
ElYes            WZINo If yes to any of the above it ems, provide the information required in the S LUDGE TECHNICAL REPORT.
New authorization for beneficial land application, incineration, and sludge lagoons in the TPDES or TLAP permits requires a major a mendmentto t he p ermit. New authorization for composting may require a major amendment to the permit. See the instructions for an explanation whether a major amendment Is required or if authorization for composting can be added through the renewal process.
TCEQ-1 0055 (05/15/2012) Industrial Wastewater Permit Application Technical Report        Page 46 of 66
 
Attachment NOC-AE-14003142 Page 67 of 155 Worksheet 7.0 Storm Water Runoff
 
Attachment NOC-AE-14003142 Page 68 of 155 WORICSHEET 7.0 STORMWATER RUNOFF WORIKSHEET REQUIRED FOR ALL TPDES PERMIT APPLICATIONS APPLYING FOR INDIVIDUAL PERMIT COVERAGE FOR DISCHARGES OF STORM WATER RUNOFF.
: 1. Do discharges from a ny of the p roposed or e xisting outfalls consist of stormw ater runoff only o r s tormwater runoff and any of the l isted n on-stormwater discharges?
(See Instructions, Page 79)
W-Yes         IZINo If yes, proceed as directed. If no, stop here.
: 2. Indicate by a check mark which type of authorization covers or is proposed to cover discharges from each stormwater outfall. (See Instructions, Page 79)
U.n.:.e::**:.r:...**.:.                          :.....                      ..u a....
outfallI       coverage                   Coverqag U'nde.r       oulI           coverbkoe     ,
coverage         Under-UdrMGP                 Indiv"idual. Permit     utar         Under MSGI'   In'dividual Pelrnit&#xfd;
: 4.                         4.                       .11           4               L 4   -                       4*                       -II     -     I
                        -                     J.                       .11           A             - L If you have indicated that all existing or proposed stormwater outfalls are covered under the MSGP, stop here. If you have indicated that you are seeking authorization under an individual permit, proceed as directed.
TH OU~0*               GVrM ARE                                               R]IAC
                                                                                  !EQ.~~)F obTFAtlHA.                       ..
DISCH GES StOIMWATERANDT OR WT6IIfY`OtJARESEEKICN(
~N W&#xfd;MALftTO1UZATON UNDER MlIfS PERMIT APPLICATION.
Indicate by a check mark that a site map(s) of the entire facility has been provided with the following information.
Indicate by a check mark that a site map(s) of the entire facility has been provided with the following information.
H the location of each stormwater outfall to be covered by the permit;an outline of the drainage area that is within the facility's boundary and that LI nI nI El contributes storm water to each outfall to be covered by the permit;connections or discharge points to municipal separate storm sewer systems;locations of all structures (e.g. buildings, garages, storage tanks);structural control devices that are designed to reduce pollution In storm water runoff;process wastewater treatment units (including ponds);bag house and other air treatment units exposed to precipitation or runoff;landfills; scrapyards; surface water bodies (including wetlands);
H       the location of each stormwater outfall to be covered by the permit; an outline of the drainage area that is within the facility's boundary and that contributes storm water to each outfall to be covered by the permit; LI connections or discharge points to municipal separate storm sewer systems; nI locations of all structures (e.g. buildings, garages, storage tanks);
TCEQ-1 0055 (0511512012)
nI structural control devices that are designed to reduce pollution In storm water runoff; process wastewater treatment units (including ponds);
Industrial Wastewater Permit Application Technical Report Page 51 of 66 Attachment NOC-AE-14003142 Page 69 of 155 E vehicle and equipment maintenance areas;ED physical features of the site that may influence stormwater runoff or contribute a dry weather flow;D locations where spills or leaks of reportable quality (as defined in 3o TAC &sect;327.4)have occurred during the three years b efore this application w as submitted t o obtain coverage under an individual permit; and ED processing areas, storage area, material loading/unloading areas, and other locations where significant materials are exposed to precipitation or runoff.a. Provide an inventory, or list, of materials currently handled at the facility that may be exposed to precipitation.
El bag house and other air treatment units exposed to precipitation or runoff; landfills; scrapyards; surface water bodies (including wetlands);
: b. Provide narrative descriptions of the industrial p rocesses and activities involving the materials in the above-listed inventory that occur outdoors or in some manner that may result in exposure of the materials to precipitation or runoff.TCEQ-1 0055 (05/15/2012)
TCEQ-1 0055 (0511512012) Industrial Wastewater Permit Application Technical Report                           Page 51 of 66
Industrial Wastewater Permit Application Technical Report Page 52 of 66 Attachment NOC-AE-14003142 Page 70 of 155 c. Describe any best management practices and controls that you are using to prevent or effectively reduce pollution in stormwater discharges from the facility.TCEQ-1 0055 (05/16/2012)
Industrial Wastewater Permit Application Technical Report Page 53 of 66 Attachment NOC-AE-14003142 Page 71 of 155 poJVA4 4-t1$ ~ ti gs800)a. TABLE i-SW: Please complete the table as directed.Outfall ____MXUM~VAL~
nflYA ~ ~ ~ ~/.Grab "lw Grab Plow Number 'of Sml Weighted Sample Weighted Storm M1AL Composipotie
~~ 116tI~~rn Sample 7 Sampled pH (Standard Units) (min) (max) (min) (max) .....Total Suspended Solids Chemical Oxygen Demand Total Organic Carbon OIl and Grease Total Arsenic 0.010 Total Barium 0.010 Total Cadmium 0.001 Total Chromium '0.010 Trivalent Chromium Hexavalent Chromium 0..010 Total Copper 0.010 Total Lead 0.005 Total Mercury ...0.0002 Total Nickel 0.010 Total Selenium 0.010 Total Silver 0.002 Total Zinc 0.005 TCEQ-10055 (05/15/2012)
Industrial Wastewater Permit Application Technical Report Page 64 of 66 Attachment NOC-AE-14003142 Page 72 of 155 b. TABLE 2-SW: Please complete the table as directed. (Instructions, Pages 8o)STR EE~TO K(t"q~ Pag.Please provide the following data for the storm event(s) which resulted in the maximum values for the analytical data submitted:
a.b.C.d.e.g.Date of storm event: Duration of storm event (in minutes): Total rainfall during storm event (in inches): Number of hours between beginning of storm measured and end of previous measurable rain event: hours Maximum flow rate during rain event (gallons/minute):
Total stormwater flow from rain event (in gallons): Provide a description of the method of flow measurement or estimate: TCEQ-1 0055 (05115/2012)
Industrial Wastewater Permit Application Technical Report Page 55 of 66 Attachment NOC-AE-14003142 Page 73 of 155 Attachment A Copy of Application Fee 4 Submission Checklist, Pg. 1 Attachment NOC-AE-14003142 Page 76 of 155 Attachment B USGS Maps (Admin Report 1.0 -8.m., Pg. 12 Attachment NOC-AE-14003142 Page 77 of 155 THIS PAGE IS AN OVERSIZED DRAWING OR FIGURE, THAT CAN BE VIEWED AT THE RECORD TITLED: BLESSING SE, TX DMA 6741 I SE-SERIES V882 Attachment B 1USGS MAP WITHIN THIS PACKAGE...
02D01 THIS PAGE IS AN OVERSIZED DRAWING OR FIGURE, THAT CAN BE VIEWED AT THE RECORD TITLED:PALACIOS NE, TX, DMA 674111 NE-SERIES V882 Attachment B USGS MAP WITHIN THIS PACKAGE...
02D02 THIS PAGE IS AN OVERSIZED DRAWING OR FIGURE, THAT CAN BE VIEWED AT THE RECORD TITLED :IM[ATAGORDA,TEX, AMS 6841 III NW-SERIES V882 Attachment B USGS MAP WITHIN THIS PACKAGE...
02D03 THIS PAGE IS AN OVERSIZED DRAWING OR FIGURE, THAT CAN BE VIEWED AT THE RECORD TITLED: WADWORTH,TEX, AMS 6841 IV NW-SERIES V882 Attachment B USGS MAP WITHIN THIS PACKAGE...
02D04X Attachment NOC-AE-14003142 Page 82 of 155 Attachment C Affected Landowners Admin Report 1.1 -I.a. & b., Pg. 15 Attachment NOC-AE-14003142 Page 83 of 155 LEGEND_____ South Toxas Nucear Plant-Adjacent Landowners A Outfial Location* kntenl Monwfto Points Upstreanrvownstrea Markers-- Disharge Route a 200 4X SOUTH TEXAS NUCLEAR PLANT MATAGOR.DA COUN~TY. 7EXAS ATTACHIENT C AFFECITE LANOWES AP-It my tt *sin wj. ao.T4 O.Cs'b Vts , Um PLS Attachment NOC-AE-14003142 Page 84 of 155 MAPIl 3 2 3 4 5 6 7 0 N 10 11 12 13 14 15 16 17 1i 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 33 39 40 41 42 43 44 45 45 47 40 49 51 52 53 54 55 56 57 so 59 60 61 62 63 64 65 66 67 68 69 7n 71 7Z 73 74 75 76 77 78 70 81 83 64 05 07 8R 00 91 02 RIle...otn AARON REVOCABLE TRUST ABER WILLIAM M 1R & LAURA A ABER ADAMS ALLEN M ALKIRE WILULAM & LYNN O'BRIEN ALLEN MAREE L & EDITH M LANIER PRU ITT ARNIM A H 5 CARYN BARTON GARY R & DEANNA M BARTON SEAN E & BETH A BENNETT TIMOTHY T & CONNIE I BLACK MICHAELW & ALUSON BOWERS V Y BRANIFF JOHN R JR & MELISSA BROWN DIANA L BROWN TRACE PROPERTIES LTD BURDITTTOMMIE W & JUDY L & TROY W JO A CANTRELL JAMES S CARROLL JOHNNIE LEE CARROLL WAYNE & SUE CHANCE FARM CHAPPELL COLEY & LOREE ELTON CHERYL WIITE INC COLUER BILL & RUBY COR0RON ALLEN ROY COX JANE M COX THOMAS BRENT &TERRI LYNN CRAIN GARY & KAREN COANEJOE M CULVER RAY M JR DAVIS CLYDE I DAVIS JEFF R & BETTY S DAY JEREMY DEFEHR KEITH D & BARBARA DENHAM ALFRED B DORR FRANK D DZIUK ROBERT J/HELEN/JEFFERY&
STACYATTAWAY ELYJAMESE ESTES DANIEL EDWARD III & TAMMY RESEE EXOTIC ISLE HOMEOWNERS ASSOC FALTYSEK NATHAN RAY & KERA FLORE5 JAMES W & THOMAS 0 FLOYD CHARLES R ESTATE FREEMAN FAMILYTRUST GAERTNER DEAN R & MARY BESH GAERTNER GATELY FRANCIS & JOY D GAVENDER M E & ROSALIE GAVENDER RONALD F GILLILAND ANGELA M GOODMAN LESLIE L GREGORY JAM ES F GROTH ALISON E GST EXEMPT DE3CENDANTS TRUST GROTH CARL E & KATHY D HANSEN DORIS BUNGE FAMILY TRUST 2012 HARRISON GEORGE R & DONNA CORNELIUS HENDERSON ROBERT K JR HICKS MICHAEL & CHARLENE HINOTE RUSSELL E & DIANE HOWAATON MARION L & VWCKIE E HUBBARD PROPERTIES LTD HUGHEYJOHN R IVY DONALD D & JOYCE JANISE NATHAN S & PAMELA S JOHNSON DIRK 19 KIM8RA K JONES JEANNIE R KEY MARTIN L & DONNA L KIENTZ CALVIN W KIRBY BRENTT & SUE W KNAPP DEBBIE KIRE SOSTESSAUDER HARRY 8 & SHERYE. L SZEINBACH KRENEK LARRYJ & DEANNA H LANDERS JOHN S SR & JANE C LEDWIG JULIUS H RR & SCOTT D LEDWIG LEISSNER DAYTON LANE LESLIE JESSICA LIGUMS JOHN E & IENNIFER H LOYACANO RAY DALE & FRANCES MARTIN JERRY L & KATHRYN MASSEY DAVE & NANCY SPEICH MATHERNE TERRY A & SUSAN K MCELMURRAY ELI HENRY MCGEE CLAUDE & BARBARA PRESLEY MCKINLEYJESSE G ETAL MILER SEAN GORDON MILLER RONNIE LAVELLE MOBLEY LARRY W & CAROL I MOFFITT REAL ESTATE I LLC MONTGOMERY JACK C & BARBARA I MORRIS STEVE I NIELSEN DONALD & MARY JEAN OCONNEILL PATRICK I OWEN BESSIE MAE PAJESTKA BLANCHE PETRVALSEK GERALD& MARGARET ELLEN PETRVALSKY addrjine2 SB ENGUSH OAK 1640 CR243 1610 CR 243 372 CR 243 18350 FENSKE BRB EXOTIC ISLE 4708 WELFORD DRIVE 471 USNDEN 2700 CYPRESS SPRINGS LN 1618 CR243 P G BOX 799 6230 LYNBROOK 2076 CR 243 3606 YVENUE F 5924 HOMESTEAD 302 EMPRESS LANE 1071 CR 385 352 CR 243 P F BOX 0265 2010 CR 243 607 SALERNO H61 CALADIUM COURT 625 GREEN DEWITT RD 1540 CR 243 550 CR 243 SELKIRK RD 1190 CR 243 (SELKIRS RD)2909 OAK DR 306 PRIVATE ROAD 608 1320 CR 243 SELKIRK RD P 0 BOX 3196 10684 CRf303 P 0 BOX 126 P G BOX 1792 17603 WESYTLEIGH DR 1824 SUNSET DR 1700 GOLDEN AVE RI100 P0 BOX 27 1322 BETEEL 2021 HIAMILTON DRIVE J1B3 WILLOW STREET 1700 :COUNTY ROAD 243 P G BOX 789 27002 MESA VERDE DRIVE 1802 CR 243 1990 CR 243 PG EOX 372 R20TW 3TH ST 18100FFPP 411 S BELKNAP ST SSSS SAN FELIPE STE 200 2811 GOLDEN LARCH DR 7282 1'M 521 2486 CR 222 535 AZALEADELL DR 20822 RIVA FUDGE 2315 OAKVIEW DR 720 CR 243 PO BOX 2&3 59 EXOTIC ISLE DRIVE 2058 CR 243 592 CR 243 3313 ASPENBEROOK COURT 726 S PRAIRIE RD 9810SPINGFIELD RIDGE DR 3669 FM 2268 P 0 BOX 32 PG BOOX 4179 P0 BOX 211101 32653 PECAN HILL 2014 COUNTY ROAD 243 P G BOX 190 5619 CR 112 110 CANYON DRIVE 3736 KNOLLWOOGST 448 CR 243 1R78 CR 243 4021 BYRON 4841 BRAIRBEND DRIVE 1718 CR 243 700 AVENUE F NORTH 12522 CAMPSITE TRAIL P0BOX669 2404 AVENUE H 1810 CR243 13002 KLUGE RD 435 FOX BRIAR LANE 5151 EDLOE APT9107 1910 C R 243 10101 SOUTHWEST FWY STE 100 15318 ARHWOOD DR P 0 BOX 105 6717 COTTON add_dRW LAKE JACKSON BAY CITY SAY CITY BAY CITY CYPRESS BAY CITY BELLAIRE BELLAIRE CYPRESS BAYCITY PALACIOS HOUSTON RAY CITY BAY CITY ROSENBERG LEAGUE CITY PALACIOS BAY CITY WICHITA FALLS SAY CITY SUGAR LAND LAKE JACKSON CUERO BAY CITY BAY CITY BAY CITY BAY CITY BAYCITY BAY CITY PORTLAVACA PLANTERSVILLE WADSWORTH RAY CITY HOUSTON BAY CITY RAY CRY EL MATON HOUSTON ROSENBERG BAY CITY BAY CITY BROOKSHIRE MAGNOLIA BAY ERY BAY CITY WADSWORTH HOUSTON PASADENA SUGARLAND HOUSTON KATY PALAClOS BAY CITY HOUSTON FAIR OAKS RANCH MISSOURI CIE BAY CITY VAN VLECK BAY CITY DAY CRIY BAY CITY PEARLAND NEW LENOX KATY BAYICRY WADSWORTH HOUSTON COLUMBUS BROOKSHIRE BAY CTY BLESSING VAN VLECK SAN ANTONIO HOUSTON BAYCETY BAY CITY HOUSTON HOUSTON BAY CIE BAY CITY CYPRESS 8AY CERY BAY CETY BAY CITY CYPRESS SUGAR LAND HOUSTON RAY CITY HOUSTON SUGARLAND HOLLAND HOUSTON addr..%ate"TX Tx Tx"TX TX Tx TX TX TX TX TX TX Tx Tx TX 0X TX TY TX TX TX TX 03 0X T3 TX T3 TX T3 TX TX T1 03 TX TX Tx Tx TX TX T0 0X 03 T5 T3 TY 03 T3 T3 03 TX 03 T3"X 03(IL T3 TX T0 TX OH TX TX TX TX TX TX T3 TX T3 T3 T3 TX T3 T3 0X T1 IL TX T3 TX TR TX zip 77566 77414 77414 77414 73433 77114 77401*77401 77433 77414 77465 77037 77414 77414 77471 77573 77465 77414 76307 77414 77478 77566 77954 77414 77414 77414 77414 77414 77414 77979 77363 77483 77404 77077 77414 77414 77440 77055 77471 77414 77414 77423 77355 77414 77414 77483 77018 77502 77478 77056 77494 77465 77414 77018 78015 774159 77114 77.00 77414 77414 77414 77581 60,151 77494 77414 71413 77210 43221 77423 77414 77419 77402 78209 77019 77414 77414 7700S 77035 77414 77414 77429 77404 77414 77414 77429 77478 7700D 77414 77074 7747B 76534 77092 Attachment NOC-AE-14003142 Page 85 of 155 PHILLIPS BRIAN M & PAMELA A PLUMMER CHIEDRENS' TRUST PLUMMER MATTHEW W JR TRUSTEE POPP CEDRIC E &JOANN POSTER WARTREUR 1999 REVOCABLE POSWAY JOHN P & ELISSA PURYEAR MARILYN ANN PYATTE JOSEPH B QUINNEY JOSEPH F RADITE TRAVIS WILUAM & NICOLE P REUSE RUSSELL P & ALYCE J RICHARDSON JERRY & BARBARA ROBERTS PAUL D & LINDA I ROY CHRIS A & KELLIE D RUNNELLS CLIVE III RUNNELLS CLIVE IV SAHA JOHN BYRON & AMANDA KAY SALAZAR RUBEN SAMS CLEO LESTER & MARY K SAVAGE JOHIN MORRIS SAVAGE KEN & CINDY SCHEPS BRENT SCHWARTZ SIDNEY TRUSTEE SELKIRK ISLAND IMPROVEMENT COMMITTEE SHEPPARD IIENRY C SHERRILL KAREN SILLERS CYNTHIA B REV TRUST SILVERTHORNE KENNETH W SNYDER JAMES EUGENE & CAROLYN L SPECK FAMILY LIVING TRUST SPROTT HANNAH ASHIEY SPROTT SHERRY L CULVER STEFFEK KEITH A & JONNIE E SZEINBACH SANDY A TALASEK MELVIN B TALASEK MICHAEL M & KARSE J TALASEK THE SCHINDLER UVING TRUST THOMAS HARRY R 1R & DIANA TILLER DAVE GUY I11 & TALBOTT FAMILY LIVING TRUST TRACY TRENT N TRAHAN RONALD L & GAIL E TURNER GERALD DALBERT A IR & ANNETTE L VANCE JOAHN T III & ELIZABETH VAUGHAN WATTS RARD & PATSY KAYE VAUGHA N VAVRA JARRETT &TAMMY VAVRA MILTON JR WALKER TED L & LORT I WARR KENNETH H JR & CHRISTIAN SWINBANK WEDEMEIER THOMAS M WENZEL CHARLES E & MARIELLEN WESTMORELAND GREG B WIKOFP LEE E A KERRI WINTERS JOSEPH P & DOLORES YOUNG ROBERTAUSTIN ZABOROSKI EUGENE & SELPHINE ZARRANSKY MICHAEL C & RUTH 5EW HIGHWAY 36 N 2101 CRAWFORD ST STE 302 2101 CRAWFORD SUITE 204 4612 CR 410 RD 4408 LONG CHAMP DR APT S8 6903 ELM TRACE DR 334 CR 243 / SELKIRK RD 1070 CR 243 P 0 6X.71 E13 TWIN PINES DR 30702 MCKINNEY DR P B BOX 911 2901 7TH 1TR363 P C BOX 926 P 0 EOX 5097 P 0 EOX 5097 2E95 CR 391 4702 MIMOSA CIR 2(B CR243 4797 FM 2853 1652 CR 243 550 COLLEGE 1940 AVENUE G 1650CR243 5207 MARBLE GATE 11707 CEDAR POI NT COURT 5555 45TH ST 1574 CR 243 1930 CR 243 SELKIRK RD 11D2 SYCAMORE RD 9479 LIGH.SEY LN 9479 LIGHTSEY LN 7601 SWANSON DR 1054 CR 243 P 0 BOX 397 P 0 B DX 278 1LS WEST EVANS 2108 CR 243 2613 TUPELO P 0 BOX 350 2704 CR 243 33Z7 EAST OVERDALE 7402 FP 361 3100 AVENUE H 1493 CR 243 3458 CR 384 415 CR 353 402 MAIN 9TH FLOOR P 0 BOX 1127 1420R5243 2701 PARKWAY 18 VALHALLA DR 1650 CA 243 252 CR 243 P0.BOX632 184 LCR 743 A 6529 MERLIN BELLVILLE HOUSTON HOUSTON ELCAIMPO AUSnN SUGARLAND BAY CITY BAY CITY MARKHAM FRENDSWOC)D TOMBALL WADSWORTH BAY CITY SANTE FE AUSTIN AUSTIN PALACIOS RICHMOND BAY CITY PALACICS DAY CITY BELLAIRE BAY CITY BAY CITY HOUSTON HOUSTON MOORHEAD BAY CITY BAY CITY RICHMOND COLLEGE STATION COLLEGE STATION RICHMOND DAY CITY WADSWORTH MATAGORDA WHARTON BAY CITY BAY CITY WADSWORTH BAY CITY PEARLAND RICHMOND BAY CITY BAY CTTY PALACIOS PALACIOS HOUTO N FULSHEAR BAY CITY ROSENBERG BAY CITY BAY CETY BAY CIT" MATAGORDA THORNTON HOUSTON 77418 77002 77002 77437 78746 77479 77414 77414 77456 77546 77375 77483 77414 77517 78703 79763 77465 77406 77454 77465 77414 77401 77414 77414 77069 77070 65160 77414 77414 77469 77540 774G6 77414 77463 77457 77488 77414 77414 77483 77414 77584 77469 77414 77414 77465 77465 77002 77441 77414 77471 77414 77414 77414 77457 76687 77055 f\.,. /
Attachment NOC-AE-14003142 Page 86 of 155 Attachment D Original Photographs Admin Report 1.1 -2., Pg. 12 Attachment NOC-AE-14003142 Page 87 of 155 RPS Attachment NOC-AE-14003142 Page 88 of 155 Attachment D -Outfall Photos Photo1 -Outfall 002 Photo 2 -Outfall 001, Looking downstream Attachment NOC-AE-14003142 Page 89 of 155 Photo 3 -Outfall 001 looking out Photo 4 -Outfall 003 Attachment NOC-AE-14003142 Page 90 of 155 Photo 5 -Outfall 004 Photo 6 -Outfall 005 Attachment NOC-AE-14003142 Page 91 of 155 Photo 7 -Outfall 006 Attachment NOC-AE-14003142 Page 92 of 155 Attachment E USGS Map SPIF, Item 8 Attachment NOC-AE-14003142 Page 93 of 155 Downstream of OutOfll 003 1WIMile Doitam of Downstream Outf 00 1 & 004 O u t fa U l 0 0 53 W a I s h o n n the. FullSze"W SouthTexn ud....lan Map as required.Imile radius N A outfall Location 0 2,500 5%ODO* Intemal Monitoring Points FEET Ad War WMR Locations (TWDB) 4 -C = =rw, DRAWN SY: SB WIVLSON SOUTH TEXAS NUCLEAR PLANT MATAGORDA COUNTY, TEXAS APPROVED BY: T KOEIN PROJECT NO: 2014 TPDES ATTACHMENT E FILE NO. STNSPIF MAP.m,.SPIF USGS MAP DATE. MAY2014 A; = W sz: M M-9ml, &#xfd; win a ' I &#xfd; -
Attachment NOC-AE-14003142 Page 94 of 155 Attachment F Wastewater Generating Process Tech Report 1.0 1.c., Pg. 1 Attachment NOC-AE-14003142 Page 95 of 155 Attachment F -Wastewater Generating Process Main Cooling Reservoir
-- Outfall 001 Outfall 001 is the discharge point for the 7,000-acre main cooling reservoir.
This reservoir is part of the main recirculating cooling water loop used to remove heat from the steam-electric generating units.There has not been a discharge from Outfall 001 since March 1997 otherthan minor permitted leakage through the closed spillway gates and relief wells. If a discharge were to occur, blowdown from the main cooling reservoir would make up the largest percentage of wastewater.
A discharge from Outfall 001 would flow to the Colorado River (Colorado River Tidal in Segment 1401 of the Colorado River Basin).All internal outfalls (Outfalls 101, 201, 401, and 601) discharge to the main cooling reservoir.
Outfall 501 would also discharge to the reservoir via Outfall 101, but has not discharge since 1992.Low Volume Wastewater (Outfalls 101 and 201)Low volume wastewater results from water treatment operations, boiler blowdown, HVAC blowdown, floor drains, SPCC sources and their associated oily water treatment system discharges, and other miscellaneous sources. Boiler blowdown is from one auxiliary steam boiler, released to reduce impurities in the water that can cause corrosion and boiler tube failure. Service water is demineralized and regeneration of the demineralizer resin beds produces an acidic and caustic wastewater that is treated at the neutralization basins along with boiler blowdown.
The floor drain system captures condensate and water from production and maintenance areas that may contain oil or grease, which is then transported to the oily waste treatment system where the oil is separated from the water. The first flush of stormwater from some production and storage areas is also treated in the oily waste system. Other non-processstormwater flow is directed through designated stormwater outfalls.Treated Domestic Wastewater (Outfalls 401 and 601)Domestic wastewater is treated onsite in two package treatment systems consisting of aeration, clarification, and disinfection.
Car wash water, air conditioning condensate, HVAC cooling tower blowdown, and stormwater are commingled with the domestic wastewater prior to treatment.
Metal Cleaning Waste (Outfall 501)Metal cleaning waste has not been discharged since 1992. Metal cleaning using chemical or non-chemical liquids produces a waste that would be discharged through Outfall 501 to the neutralization basins (Outfall 101). Stormwater may also be discharge through Outfall 501.Main Cooling Reservoir (MCR) Relief Well Effluent (Outfolls 002-006)MCR relief well effluent is collected from the perimeter of the MCR and discharge via Outfall 002-006 without treatment.
Outfall 002 is also authorized to discharge demineralized water from Instrumentation.
Attachment NOC-AE-14003142 Page 96 of 155 Attachment G Facility Plot Plan Tech Report 1.0- I.e., Pg. 2 Attachment NOC-AE-14003142 Page 97 of 155 I h ii II LEGEND Soulh T~*as I*,dsor Pft LUnfts I &#xa3;2 A OujhILocaflbn 0 knesiAo MwV cib t) k qi&#xfd;ATTACNMNTO FACOfrYS MTAP mo w tsvamo so&&US1~~m T~ S l~.r 3m IWA0U IIIM ILDUIA;LrAi PLA"I MATAGAM COUNIY. 7EXA&#xfd;w mm MET IS-w~'=1 rn-U-----
Attachment NOC-AE-14003142 Page 98 of 155 Attachment H Flow Schematic Diagrams Tech Report 1.0- 2.b., Pg. 3 Attachment NOC-AE-14003142 Page 99 of 155 Colorado River Notes: Outfall has not discharged since March 4, 1997.** Outfall has not discharged since December 1992.SOUTH TEXAS NUCLEAR PLANT MATAGORDA COUNTY, TEXAS ATTACHMENT H FLOW SCHEMATIC
-OUTFALL 001 DRAW,/N BY SSW"LSOD I SCALE! PROJ. 2014TDOES CHECKED BY: T KOENINGS De. b sRRI F[LE NO. STNoFI.. D.o0r,,e..wg APPROVED BY: DATE PRINTED DATE: U, 12, 231 A-t S, &#xa3;.dA a Attachment NOC-AE-14003142 Page 100 of 155 Effluent from Relief Wells W1.W125 Plant drainage ditch to Colorado River, Tidal OUTFALL 002 Am -w Demineralized Water from Instrumentation SOUTH TEXAS NUCLEAR PLANT MATAGORDA COUNTY, TEXAS ATTACHMENT H FLOW SCHEMATIC
-OUTFALL 002 DRAWAN BY: S,3VLSON SCALE: PROJ. 201 4TPDES CHECKED BY:T KOE WJINDS Z.. b., -le FILE NO. SRJI4 Osa APPROVED BY: -DATE PRINTED: DATE: M.,t 2.2014[ 7R&#xfd; 7PS ]t~M 0.,* R*01,g 57 R.3. 100 2050 C*Ol.1 tl Ta,.. H~5W*II S0011 01,140 r.n, 7,745 010.51 1.7145 I Attachment NOC-AE-14003142..
Page 101 of 155 OUTFALL 003 I Effluent from Relief Wells WI 38-W195 I West Branch of the W Colorado River OUTFALL 004 Effluent from Relief Wells W196-W268 Main Cooling Reservoir Spillway W OUTFALL 005 AI East Fork Little Robbins Effluent from Relief Wells W269-W483 w SloughI OUTFALL 006 Effluent from Relief Wells W483-W670 Little Robbins Slough i -a-SOUTH TEXAS NUCLEAR PLANT MATAGORDA COUNTY, TEXAS ATTACHMENT H FLOW SCHEMATIC
-OUTFALL 003, 004, 005, 006 DRAM BYA: SSWMLSON SCALE: PROJ. 2014WMES CHECKED8Y:TKOENINGB Se 'br oIP FILENO. ' LL...l, APPROVEDI BY DAE PRINTED: DATE: 14 0 CIA 0 Rp&#xfd;S DV, On. BI44~g2'.
DVi 000 0404 Cot.S.VTIa.JVOA.,.o.
S~4A A4t 70,08 10740 d(2041.7MD b
Attachment NOC-AE-14003142 Page 102 of 155 LOW VOLUME WASTEWATER including wastewater from the following operations and sources:.* demineralizer regenerant wastewater;
* condenser polishing regenerant wastewater;
* boiler blowdown;* boiler drainage;.
* laboratory, instrument, and sampling sources;* well water filter backwash;* water softener regenerate;
* floor drains in chemical storage containment areas;* rinse water from triple rinsing empty chemical drums;, fuel handling building HVAC blowdown; and* miscellaneous low volume wastewater.
recirculation line--------------------
I -NEUTRALIZATION BASINS Neutralization*
Mixing*Sedimentation OUTFALL101 to Main Cooling Reservoir sludge to landfill Metal Cleaning Waste Effluent (Outfall 501"*)Storm Water Notes: 'Treatment may be used based on influent quality-Outfall 501 has not discharged since December 1992.SOUTH TEXAS NUCLEAR PLANT MATAGORDA COUNTY, TEXAS ATTACHMENT H FLOW SCHEMATIC
-OUTFALL 101 DRAMI BY: SSWILSON SCALE. PR04, 2514TPOES CHECKED BY:KOENINOS Be*ba 5cl. ,t FILE NO0. GNJS.Y.*Stl,,t APPROVED B:jS 22 DAT PRINTYED DATE: I Attachment NOC-AE-14003142 Page 103 of 1556 sludge to incineration and/or landfill----w- filter media to landfill SOUTH TEXAS NUCLEAR PLANT MATAGORDA COUNTY, TEXAS Notes:*** Treatment process may be used based on influent characteristics.
ATTACHMENT H FLOW SCHEMATIC
-OUTFALL 201 SS=tLSON SCAL.E: PROJ. 2E14TPDES"KOENINGS1 See Sa' cIe FILE NO. NFSw ,-DATE PRINTED: I&#xfd;&#xfd;M r RPSI 01.5 C..t. A.iObOR S,,*bIX 1210 C~ftI~4 ShVft~.o 00051 70043 P~T0O Attachment NOC-AE-14003142.
Page 104 of 155 AERATION TANKS Activated Sludge Foam Suppression Screening L -----------------
OUTFALL 401 DIGESTER Sludge to landfill ---Aerobic Digestion to Main Cooling Reservoir SOUTH TEXAS NUCLEAR PLANT MATAGORDA COUNTY, TEXAS ATTACHMENT H FLOW SCHEMATIC
-OUTFALL 401 DRAMN BY: SSVVILSON SCALE: PROJ. 2014ITPDES CHECKED BY: T KOENINOS S50 b.-.1 FS~ ILE NO. DThYoa APPROVE BYOR DATE PRINTED: DATE:-~~2 1~- H5,-,.S1 O monommomwjb&#xfd; Attachment NOC-AE-14003142 Page 105 of 155 Metal Cleaning Wastetwater Inorganic Basin-- Coagulation' Chemical Precipitation*
Sedimentation to Outfall 101 OUTFALL 501 (no discharge since 1992)Storm Water SOUTH TEXAS NUCLEAR PLANT MATAGORDA COUNTY, TEXAS ATTACHMENT H FLOW SCHEMATIC
-OUTFALL 501 DRAWN BY: SSW1LSON SCALE PROJ. 2014TPOES CHECKED BY; T KOEtNO1 S U0 bar ato j FRLE NO. ST._Fl R- ,.g APPROVED BY: -DATE PRINTED;DATE; Ua. 12. 20114 Notes:* Treatment process may be used based on influent characteristics.
I RPS]23* Card,.. B.do23I 23,4?. 2300 42350 CR232323 at 31,50 N00fl. Stat,*a,1431 Faa.. 00746 i Attachment NOC-AE-14003142 Page 106 of 155'AERATION TANKS Activated Sludge Foam Suppression Screening-------------------
OUTFALL 601 DIGESTER Aerobic Digestion I. to Main Cooling Reservoir sludge tolandfill SOUTH TEXAS NUCLEAR PLANT MATAGORDA COUNTY, TEXAS ATTACHMENT H FLOW SCHEMATIC
-OUTFALL 601 DRAWN RY: SD LSON SCALE: PROJ. 2014TPDES CHECKED BY: T KOEINGS So.. batb scar FILE NO. STNFl, FIS-ll,.E,.
APPROVED RY: -DATE PR1NTE: DATE: 0. 201"TA IML AI 20 a Attachment NOC-AE-14003142 Page 107 of 155 Attachment I Water Treatment Chemicals Tech Report 1.0- 5.c., Pg. 8 Attachment NOC-AE-14003142 Page 108 of 155 Treatment Chemicals Product Manufacturer Use Components Listed in CAS Frequency of Toxicity Product Name MSDS Use Data Concentration In MSDS Sodium ypolorite 7681 3 times per day LiquichSor Univar :Biocidt for 20 minutes to Yes 0.15-0.6 ppm total 1310e73- unit's cooling residual chlorine Sodium Hydroxide 2 water Sodium nitrite 7632 As needed to 0.25 oz per gallon of 1359 Plus Nalco Corrosion inhibitor 0 maintain No closed cooling system 7775-19-Sodium nictaborate concentration water 1 19H Nalco Oxygen scavenger Hydrazine 302-011-2 Continuous Yes 0.1 ppm to feedwater Sodium Nitrite 7632 As needed to LCS-60 Nalco Corrosion inhibitor 0 maintain No 500-1500 ppm sodium Sodium Tetraborate 1330 concentration nitrite concentration


===4.1 Scale===
Attachment NOC-AE-14003142 Page 69 of 155 E      vehicle and equipment maintenance areas; ED      physical features of the site that may influence stormwater runoff or contribute a dry weather flow; D      locations where spills or leaks of reportable quality (as defined in 3o TAC &sect;327.4) have occurred during the three years b efore this application w as submitted t o obtain coverage under an individual permit; and ED      processing areas, storage area, material loading/unloading areas, and other locations where significant materials are exposed to precipitation or runoff.
Polyacrylic Acid N/A Continuous 935cNlcoNo 0.25 ppm federate as inhibitor/dispersant product 3 times per day ACTI-BROM Nalco Biocide Sodium bromide 7647 for 20 minutes to Yes 0.15-0.6 ppm total.131.8 6 unit's cooling residual chlorine water B-2200 Varichem.
: a. Provide an inventory, or list, of materials currently handled at the facility that may be exposed to precipitation.
Algaecide Ethyl Alcohol 64-17-S Batch treated as No 5 ppm needed B-2206 Varichem Biocide Broimochloro-5.5-N/A Continuous No 0.5-2 ppm diniethylydantoin Scale and SC-23 10 Varichen coaroaiondinibitor None listed N/A Continuous No 80-120 ppm Attachment NOC-AE-14003142 Page 109 of 155 Didecyl-Dimethyl-7173 4 ppm as product (2.5 H-130M Nalco Biocide Ammonium chloride 52/Yr. Yes ppm. as active) to aux.Ethanol 64-17-5 cooling system for 8-hours twice per year.Magnesium Salt N/A 2-Methyl-4-Isothiazolin 2682 Batch treated as 77352NA Nalco Isothiazolin one 4 needed Yes 300 ppm 5-Chloro-2-Methyl 26172-_ 1 _sothiazolin-3-one 55-4 _ 1 Attachment NOC-AE-14003142 Page 110 of 155 UnIVAR@Univar USA Inc Material Safety Data Sheet MSDS No: Version No: 010 2014-03-18 Order No; I ZI Univar USA Inc., 17425 NE Union Hill Rd., Redmond WA 98052 (425) 889 3400 Emergency Assistance For emergency assistance involving chemicals call Chemtrec -(800) 424-9300 Attachment NOC-AE-14003142 Page 111 of 155 UNIVAR USA INC.ISSUE DATE:2011-12-21 Annotation:
: b. Provide narrative descriptions of the industrial p rocesses and activities involving the materials in the above-listed inventory that occur outdoors or in some manner that may result in exposure of the materials to precipitation or runoff.
MSDS NO:OX76685 VERSION:010 2014-03-18 COMPANY IDENTITY:
TCEQ-1 0055 (05/15/2012) Industrial Wastewater Permit Application Technical Report  Page 52 of 66
Univar PRODUCT IDENTITY:
 
Liquichiso 10-16% (Sodium Hypochsorite 10-16%)DATE: 12/21/11 PAGE: 1 OF 8 SAFETY DATA SHEET This Safety Data Sheet conforms to ANSI Z400.5, and to the format requirements and the International Chemical Safety Cards of the Global Harmonizing System.THIS SOS COMPLIES WITH 29 CFR 1910,1200 (HAZARD COMMUNICATION STANDARD)IMPORTANT:
Attachment NOC-AE-14003142 Page 70 of 155
Read this SOS before handling & disposing of this product.Pass this information on to employees, customers, & users of this product.SECTION 1. IDENTIFICATION OF THE SUBSTANCE OR MIXTURE AND OF THE SUPPLIER PRODUCT IDENTITY: SDS NUMBER: NEW MSDS DATE: COMPANY IDENTITY: COM1PANY ADDRESS: COMPANY CITY&#xfd;COMPANY PHONE: EMERGENCY PHONES: Liquichlor 10-16% (Sodium Hypochlorite 10-16%)OX76685 12/21/2011 Univar 17425 NE Union Hill Road Redmond, WA 98052 1-425-889-3406 CHEMTREC:
: c. Describe any best management practices and controls that you are using to prevent or effectively reduce pollution in stormwater discharges from the facility.
1-800-424-9300 (USA)CANUTEC: 1-613-996-6666 (CANADA)SECTION 2. HAZARDS IDENTIFICATION DANGERI!EXPOSURE PREVENTION:
TCEQ-1 0055 (05/16/2012) Industrial Wastewater Permit Application Technical Report  Page 53 of 66
STRICT HYGIENEI AVOID ALL CONTACTI RISK STATEMENTS:
 
R35 Causes severe burns.RS Very toxic to aquatic organisms.
Attachment NOC-AE-14003142 Page 71 of 155 poJVA4                4-t1$                  ~ ti              gs800)
: a. TABLE i-SW: Please complete the table as directed.
Outfall ____MXUM~VAL~                                      nflYA          ~ ~ ~ ~
                  /.Grab                                                        Grab "lw        Plow    Number 'of SmlWeighted          Sample      Weighted    Storm        M1AL Composipotie
                    ~~                                            116tI~~rn              Sample 7  Sampled pH (Standard Units)                      (min)            (max)            (min)    (max)                .....
Total Suspended Solids Chemical Oxygen Demand Total Organic Carbon OIl and Grease Total Arsenic                                                                                              0.010 Total Barium                                                                                                0.010 Total Cadmium                                                                                              0.001 Total Chromium                                                                                            '0.010 Trivalent Chromium Hexavalent Chromium                                                                                        0..010 Total Copper                                                                                                0.010 Total Lead                                                                                                0.005 Total Mercury ...                                                                                          0.0002 Total Nickel                                                                                              0.010 Total Selenium                                                                                              0.010 Total Silver                                                                                                0.002 Total Zinc                                                                                                  0.005 TCEQ-10055 (05/15/2012) Industrial Wastewater Permit Application Technical Report                    Page 64 of 66
 
Attachment NOC-AE-14003142 Page 72 of 155
: b. TABLE 2-SW: Please complete the table as directed. (Instructions, Pages 8o)
STR    EE~TO                K(t"q~                  Pag.
Please provide the following data for the storm event(s) which resulted in the maximum values for the analytical data submitted:
: a.        Date of storm event:
: b.        Duration of storm event (in minutes):
C.      Total rainfall during storm event (in inches):
: d.        Number of hours between beginning of storm measured and end of previous measurable rain event:                                hours
: e.        Maximum flow rate during rain event (gallons/minute):
Total stormwater flow from rain event (in gallons):
: g.        Provide a description of the method of flow measurement or estimate:
TCEQ-1 0055 (05115/2012) Industrial Wastewater Permit Application Technical Report  Page 55 of 66
 
Attachment NOC-AE-14003142 Page 73 of 155 Attachment A Copy of Application Fee 4
Submission Checklist, Pg. 1
 
Attachment NOC-AE-14003142 Page 76 of 155 Attachment B USGS Maps
(
Admin Report 1.0 - 8.m., Pg. 12
 
Attachment NOC-AE-14003142 Page 77 of 155
 
THIS PAGE IS AN OVERSIZED DRAWING OR FIGURE, THAT CAN BE VIEWED AT THE RECORD TITLED: BLESSING SE, TX DMA 6741 I SE-SERIES V882 Attachment B 1USGS MAP WITHIN THIS PACKAGE...
02D01
 
THIS PAGE IS AN OVERSIZED DRAWING OR FIGURE, THAT CAN BE VIEWED AT THE RECORD TITLED:PALACIOS NE, TX, DMA 674111 NE-SERIES V882 Attachment B USGS MAP WITHIN THIS PACKAGE...
02D02
 
THIS PAGE IS AN OVERSIZED DRAWING OR FIGURE, THAT CAN BE VIEWED AT THE RECORD TITLED :IM[ATAGORDA,TEX, AMS 6841 III NW-SERIES V882 Attachment B USGS MAP WITHIN THIS PACKAGE...
02D03
 
THIS PAGE IS AN OVERSIZED DRAWING OR FIGURE, THAT CAN BE VIEWED AT THE RECORD TITLED: WADWORTH,TEX, AMS 6841 IV NW-SERIES V882 Attachment B USGS MAP WITHIN THIS PACKAGE...
02D04X
 
Attachment NOC-AE-14003142 Page 82 of 155 Attachment C Affected Landowners Admin Report 1.1 - I.a. & b., Pg. 15
 
Attachment NOC-AE-14003142 Page 83 of 155 LEGEND
_____      South Toxas Nucear Plant
  -        Adjacent Landowners A        Outfial Location
* kntenl Monwfto    Points Upstreanrvownstrea      Markers
    --    Disharge Route a      200      4X SOUTH TEXAS    NUCLEAR PLANT MATAGOR.DA COUN~TY. 7EXAS ATTACHIENT C AFFECITE LANOWES AP
  -It my    *sin tt        wj.          *jw. ao.T4 O.Cs'b      Vts              ,    PLS Um
 
Attachment NOC-AE-14003142 Page 84 of 155 MAPIl RIle...otn                                            addrjine2                    add_dRW        addr..%ate      zip 3  AARONREVOCABLE        TRUST                          SBENGUSHOAK                  LAKEJACKSON                    77566 2    ABERWILLIAM      M 1R &LAURAA ABER                    1640 CR243                  BAYCITY        "TX              77414 3    ADAMSALLENM                                          1610 CR 243                  SAYCITY        Tx              77414 4    ALKIRE  WILULAM  & LYNNO'BRIEN                      372 CR 243                  BAYCITY        Tx              77414 5    ALLENMAREEL& EDITHM LANIERPRUITT                      18350 FENSKE                CYPRESS                        73433 6    ARNIMA H  5 CARYN                                    BRBEXOTICISLE                BAYCITY        "TX              77114 7    BARTON  GARYR& DEANNA        M                      4708 WELFORD  DRIVE        BELLAIRE      TX              77401 0    BARTON  SEANE &BETHA                                471 USNDEN                  BELLAIRE                      *77401 Tx N    BENNETT  TIMOTHY    T& CONNIEI                      2700 CYPRESS SPRINGSLN      CYPRESS                        77433 TX 10  BLACK  MICHAELW&ALUSON                                1618 CR243                  BAYCITY                        77414 11  BOWERS  YV                                          P G BOX799                  PALACIOS                        77465 12  BRANIFF  JOHN RJR &MELISSA                            6230 LYNBROOK                HOUSTON        TX              77037 13  BROWNDIANAL                                          2076 CR243                  RAYCITY        TX              77414 14  BROWNTRACEPROPERTIES          LTD                    3606 YVENUE  F              BAYCITY        TX              77414 15  BURDITTTOMMIE      W &JUDYL&TROYW JOA                5924 HOMESTEAD              ROSENBERG      TX              77471 16  CANTRELL  JAMESS                                    302 EMPRESS  LANE            LEAGUECITY    TX              77573 17  CARROLL  JOHNNIE    LEE                              1071 CR385                  PALACIOS                        77465 1i  CARROLL  WAYNE&SUE                                  352 CR 243                  BAYCITY        Tx              77414 19  CHANCE  FARM                                        P 0265 FBOX                      WICHITAFALLS  Tx              76307 20  CHAPPELL  COLEY  & LOREEELTON                      2010 CR243                  SAYCITY        TX              77414 21  CHERYL  WIITE INC                                    607 SALERNO                  SUGARLAND      0X              77478 22  COLUERBILL    & RUBY                                  H61 CALADIUM  COURT        LAKEJACKSON    T3              77566 23  COR0RON ALLEN        ROY                              625 GREENDEWITTRD            CUERO                          77954 24  COXJANEM                                              1540 CR243                  BAYCITY        T3 TY TX              77414 25  COXTHOMASBRENT        &TERRILYNN                    550CR 243 SELKIRK  RD        BAYCITY        TX              77414 26  CRAINGARY& KAREN                                      1190 CR243 (SELKIRS  RD)    BAYCITY        TX              77414 27  COANEJOE    M                                        2909 OAKDR                  BAYCITY        TX              77414 28  CULVER  RAYM JR                                      306 PRIVATE ROAD608          BAYCITY        TX              77414 29  DAVISCLYDE    I                                      1320CR243 SELKIRK  RD      BAYCITY        T1 03              77414 30  DAVISJEFFR &BETTYS                                    P 0 BOX3196                  PORTLAVACA    03 0X              77979 31  DAYJEREMY                                            10684 CRf303                PLANTERSVILLE                  77363 32  DEFEHR  KEITHD &BARBARA                              P BOX0 126                  WADSWORTH      TX              77483 33  DENHAMALFREDB                                        P G BOX1792                  RAYCITY                        77404 34  DORRFRANKD                                            17603 WESYTLEIGH  DR        HOUSTON        TX              77077 35  DZIUKROBERT      J/HELEN/JEFFERY&    STACYATTAWAY    1824 SUNSETDR                BAYCITY        T3              77414 36  ELYJAMESE                                            1700GOLDEN  AVERI100        RAYCRY        TX              77414 37  ESTES  DANIEL  EDWARDIII&TAMMYRESEE                  P0 BOX27                    ELMATON        TX              77440 33  EXOTICISLEHOMEOWNERS          ASSOC                  1322 BETEEL                  HOUSTON                        77055 39  FALTYSEK  NATHAN    RAY& KERA                        2021 HIAMILTON  DRIVE        ROSENBERG      0X              77471 40  FLORE5JAMESW &THOMAS0                                J1B3 WILLOWSTREET            BAYCITY        TX 03              77414 41  FLOYD  CHARLES    RESTATE                            1700 :COUNTY  ROAD243        BAYCITY        TX T5              77414 42  FREEMAN    FAMILYTRUST                                P G BOX789                  BROOKSHIRE    Tx T3              77423 43  GAERTNER    DEANR& MARYBESHGAERTNER                  27002 MESAVERDEDRIVE        MAGNOLIA      TY              77355 44  GATELY  FRANCIS  &JOYD                              1802 CR 243                  BAYERY        03              77414 45  GAVENDER    M E& ROSALIE                            1990 CR 243                  BAYCITY        T3              77414 45  GAVENDER    RONALD  F                              PG EOX372                    WADSWORTH      T3              77483 47  GILLILAND  ANGELA  M                                R20TW  3TH ST                HOUSTON        03 TX              77018 40  GOODMANLESLIE      L                                18100FFPP                    PASADENA      TX TX              77502 49  GREGORY  JAMESF                                      411 S BELKNAP  ST            SUGARLAND      T0 03              77478 GROTHALISONEGSTEXEMPTDE3CENDANTS              TRUST  SSSSSANFELIPESTE200          HOUSTON        Tx T3              77056 51 GROTHCARLE &KATHY          D                          2811 GOLDEN  LARCHDR        KATY          03(              77494 52  HANSEN  DORISBUNGEFAMILY        TRUST2012          7282 1'M521                  PALAClOS                        77465 53  HARRISON    GEORGER& DONNACORNELIUS                  2486 CR 222                  BAYCITY                        77414 54                                                                                                    T3 HENDERSON    ROBERT    KJR                          535 AZALEADELL  DR          HOUSTON                        77018 55  HICKSMICHAEL      &CHARLENE                          20822 RIVAFUDGE              FAIROAKSRANCH                  78015 56  HINOTERUSSELL      E& DIANE                          2315 OAKVIEW  DR            MISSOURICIE                    774159 57  HOWAATONMARIONL& VWCKIE            E                720 CR243                    BAYCITY                        77114 so  HUBBARDPROPERTIES        LTD                          PO BOX2&3                    VANVLECK                        77.00 59  HUGHEYJOHN      R                                    59 EXOTIC  ISLEDRIVE        BAYCITY                        77414 60  IVYDONALD    D &JOYCE                                2058 CR 243                  DAYCRIY                        77414 "X
61  JANISENATHANS&PAMELA            S                    592 CR243                    BAYCITY                        77414 62  JOHNSONDIRK19 KIM8RAK                                3313 ASPENBEROOK  COURT    PEARLAND                        77581 IL 63  JONESJEANNIE    R                                    726 S PRAIRIERD              NEWLENOX                        60,151 TX 64  KEYMARTINL&DONNAL                                    9810SPINGFIELD  RIDGEDR      KATY                            77494 T0 65  KIENTZCALVIN    W                                    3669FM2268                  BAYICRY        T3              77414 66  KIRBY  BRENTT& SUEW                                    P 0 BOX32                  WADSWORTH                      71413 TX 67  KNAPPDEBBIE      KIRE                                  PG BOOX4179                HOUSTON        T3              77210 68                                                                                                    OH SOSTESSAUDER      HARRY  8 & SHERYE. LSZEINBACH      P0 BOX211101                COLUMBUS      T3              43221 69  KRENEK  LARRYJ&DEANNAH                                32653 PECANHILL            BROOKSHIRE    TX T3              77423 7n  LANDERS  JOHNS SR&JANEC                              2014 COUNTY  ROAD243        BAYCTY        TX              77414 71  LEDWIGJULIUSH RR      & SCOTT    D LEDWIG              PG BOX190                  BLESSING      TX T3              77419 7Z    LEISSNER DAYTON    LANE                              5619 CR112                  VANVLECK      TX T3              77402 73  LESLIE JESSICA                                        110 CANYON  DRIVE          SANANTONIO    0X TX              78209 74    LIGUMSJOHNE& IENNIFER        H                      3736 KNOLLWOOGST            HOUSTON        T1              77019 75    LOYACANO    RAYDALE&FRANCES                          448 CR243                    BAYCETY        IL              77414 76    MARTIN  JERRYL& KATHRYN                              1R78CR243                  BAYCITY        TX              77414 77    MASSEY  DAVE& NANCY      SPEICH                    4021 BYRON                  HOUSTON        T3              7700S 78    MATHERNE    TERRY  A &SUSANK                          4841 BRAIRBEND  DRIVE      HOUSTON        TX              77035 70    MCELMURRAY      ELIHENRY                              1718 CR243                  BAYCIE                          77414 MCGEE  CLAUDE&BARBARA          PRESLEY                700 AVENUE F NORTH          BAYCITY                        77414 81    MCKINLEYJESSE    G ETAL                              12522 CAMPSITE TRAIL        CYPRESS        TX              77429 83    MILER SEAN  GORDON                                  P0BOX669                    8AYCERY                        77404 MILLER  RONNIELAVELLE                                2404 AVENUE  H              BAYCETY                        77414 64    MOBLEY  LARRY  W & CAROL  I                        1810 CR243                                                  77414 BAYCITY 05    MOFFITTREALESTATE      I LLC                        13002 KLUGE RD              CYPRESS                        77429 MONTGOMERY      JACKC &BARBARA      I                435 FOXBRIARLANE            SUGARLAND                      77478 07    MORRISSTEVEI                                          5151EDLOEAPT9107            HOUSTON                        7700D 8R    NIELSEN  DONALD    & MARYJEAN                        1910 CR243                  RAYCITY                        77414 TR OCONNEILL  PATRICK  I                                10101 SOUTHWEST  FWYSTE100 HOUSTON                        77074 00    OWENBESSIE    MAE                                    15318ARHWOODDR              SUGARLAND                      7747B 91                                                                                                    TX PAJESTKA  BLANCHE                                    P 0 BOX105                  HOLLAND                        76534 02    PETRVALSEK  GERALD&    MARGARET    ELLENPETRVALSKY  6717 COTTON                HOUSTON                        77092
 
Attachment NOC-AE-14003142 Page 85 of 155 PHILLIPSBRIANM &PAMELA        A                  5EW HIGHWAY    36 N        BELLVILLE                77418 PLUMMERCHIEDRENS'        TRUST                    2101 CRAWFORD  ST STE302  HOUSTON                  77002 PLUMMERMATTHEW          W JRTRUSTEE                2101CRAWFORDSUITE      204 HOUSTON                  77002 POPPCEDRICE &JOANN                                4612 CR 410 RD            ELCAIMPO                  77437 POSTERWARTREUR        1999 REVOCABLE              4408 LONGCHAMPDRAPTS8 AUSnN                    78746 POSWAYJOHNP &ELISSA                                6903 ELMTRACEDR            SUGARLAND                77479 PURYEAR  MARILYN    ANN                          334 CR243 / SELKIRK  RD    BAYCITY                  77414 PYATTE JOSEPHB                                    1070CR 243                BAYCITY                  77414 QUINNEY  JOSEPHF                                  P 06X.71                  MARKHAM                  77456 RADITETRAVIS    WILUAM&NICOLEP                    E13TWINPINESDR            FRENDSWOC)D              77546 REUSERUSSELL    P &ALYCE    J                      30702 MCKINNEY  DR        TOMBALL                  77375 RICHARDSON    JERRY& BARBARA                      P B BOX911                WADSWORTH                77483 ROBERTS  PAULD &LINDAI                            29017TH1TR363              BAYCITY                  77414 ROYCHRISA& KELLIE      D                          P BOX C 926                  SANTEFE                  77517 RUNNELLS  CLIVE  III                              P0 EOX 5097                AUSTIN                    78703 RUNNELLS  CLIVEIV                                P 0 EOX5097                AUSTIN                    79763 SAHAJOHN BYRON      &AMANDAKAY                    2E95 CR391                PALACIOS                  77465 SALAZAR  RUBEN                                    4702 MIMOSACIR            RICHMOND                  77406 SAMSCLEOLESTER      & MARYK                        2(B CR243                  BAYCITY                  77454 SAVAGE  JOHINMORRIS                                4797 FM 2853              PALACICS                  77465 SAVAGEKEN&CINDY                                    1652 CR 243                DAYCITY                  77414 SCHEPSBRENT                                        550COLLEGE                BELLAIRE                77401 SCHWARTZ    SIDNEY TRUSTEE                        1940AVENUE  G            BAYCITY                  77414 SELKIRK ISLANDIMPROVEMENT        COMMITTEE        1650CR243                  BAYCITY                  77414 SHEPPARD    IIENRY C                              5207 MARBLE  GATE          HOUSTON                  77069 SHERRILL  KAREN                                    11707 CEDARPOINTCOURT      HOUSTON                  77070 SILLERSCYNTHIABREVTRUST                            5555 45TH ST              MOORHEAD                  65160 SILVERTHORNE    KENNETH    W                      1574CR 243                BAYCITY                  77414 SNYDER  JAMESEUGENE        & CAROLYNL              1930 CR 243 SELKIRK RD    BAYCITY                  77414 SPECKFAMILY    LIVINGTRUST                        11D2SYCAMORE    RD        RICHMOND                  77469 SPROTTHANNAH      ASHIEY                          9479 LIGH.SEY LN          COLLEGESTATION            77540 SPROTTSHERRY    LCULVER                          9479 LIGHTSEY LN          COLLEGESTATION            77*45 STEFFEK  KEITH  A & JONNIEE                        7601 SWANSONDR            RICHMOND                  774G6 SZEINBACH    SANDYA                                1054 CR 243                DAYCITY                  77414 TALASEK  MELVINB                                  P 0 BOX397                WADSWORTH                77463 TALASEK  MICHAEL    M & KARSEJ TALASEK            P 0 BDX278                MATAGORDA                77457 THESCHINDLER    UVING    TRUST                    1LSWESTEVANS              WHARTON                  77488 THOMASHARRY      R1R & DIANA                      2108 CR243                BAYCITY                  77414 TILLER DAVEGUYI11&TALBOTT          FAMILYLIVINGTRUST 2613 TUPELO                BAYCITY                  77414 TRACYTRENTN                                        P0 BOX350                  WADSWORTH                77483 TRAHANRONALD      L&GAILE                        2704 CR243                BAYCITY                  77414 TURNERGERALD      D                                33Z7 EASTOVERDALE          PEARLAND                77584 URBAN*EK  ALBERT  AIR& ANNETTE    L              7402 FP 361                RICHMOND                77469 VANCEJOAHN    T III&ELIZABETH                      3100 AVENUE  H            BAYCITY                  77414 VAUGHAN    WATTSRARD&PATSYKAYE        VAUGHA  N    1493 CR243                BAYCTTY                  77414 VAVRA JARRETT&TAMMY                                3458 CR 384                PALACIOS                77465 VAVRA MILTONJR                                    415 CR 353                PALACIOS                  77465 WALKER  TEDL& LORT    I                          402 MAIN9TH FLOOR          HOUTO N                  77002 WARRKENNETH      HJR &CHRISTIAN  SWINBANK        P 0 BOX1127                FULSHEAR                  77441 WEDEMEIER    THOMASM                              1420R5243                  BAYCITY                  77414 WENZEL  CHARLES  E &MARIELLEN                    2701 PARKWAY              ROSENBERG                77471 WESTMORELAND      GREGB                          18VALHALLA  DR            BAYCITY                  77414 WIKOFPLEEE A KERRI                                1650CA 243                BAYCETY                  77414 WINTERSJOSEPHP &DOLORES                            252 CR243                  BAYCIT"                  77414 YOUNGROBERTAUSTIN                                  P0.BOX632                  MATAGORDA                77457 ZABOROSKI    EUGENE&SELPHINE                      184 LCR743 A              THORNTON                76687 ZARRANSKY    MICHAEL    C& RUTH                    6529MERLIN                HOUSTON                  77055
\.,. /f
 
Attachment NOC-AE-14003142 Page 86 of 155 Attachment D Original Photographs Admin Report 1.1 - 2., Pg. 12
 
Attachment NOC-AE-14003142 Page 87 of 155 RPS
 
Attachment NOC-AE-14003142 Page 88 of 155 Attachment D - Outfall Photos Photo1 - Outfall 002 Photo 2 - Outfall 001, Looking downstream
 
Attachment NOC-AE-14003142 Page 89 of 155 Photo 3 - Outfall 001 looking out Photo 4 - Outfall 003
 
Attachment NOC-AE-14003142 Page 90 of 155 Photo 5 - Outfall 004 Photo 6 - Outfall 005
 
Attachment NOC-AE-14003142 Page 91 of 155 Photo 7 - Outfall 006
 
Attachment NOC-AE-14003142 Page 92 of 155 Attachment E USGS Map SPIF, Item 8
 
Attachment NOC-AE-14003142 Page 93 of 155 Downstream of 1WIMile OutOfll 003                  Doitam          of Downstream Outf Ou t fa Ul 0 053 SouthTexn ud....lan the.FullSze"W Wa I s    ho n Map as required.
n 00    1 & 004 Imile radius                        N A  outfall Location                            0      2,500  5%ODO
* Intemal Monitoring Points                                      FEET Ad WMRLocations (TWDB)
War                                        4 -C = =rw, DRAWN SY:            SB WIVLSON SOUTH TEXAS NUCLEAR PLANT MATAGORDA COUNTY, TEXAS                        APPROVED BY:        T KOEIN PROJECT NO:            2014 TPDES ATTACHMENT E                            FILE NO.        STNSPIF MAP.m,.
SPIF USGS MAP DATE.                  MAY2014 A; = Wsz: MM-9ml,&#xfd;wina'I&#xfd;-
 
Attachment NOC-AE-14003142 Page 94 of 155 Attachment F Wastewater Generating Process Tech Report 1.0 1.c., Pg. 1
 
Attachment NOC-AE-14003142 Page 95 of 155 Attachment F - Wastewater Generating Process Main Cooling Reservoir -- Outfall 001 Outfall 001 is the discharge point for the 7,000-acre main cooling reservoir. This reservoir is part of the main recirculating cooling water loop used to remove heat from the steam-electric generating units.
There has not been a discharge from Outfall 001 since March 1997 otherthan minor permitted leakage through the closed spillway gates and relief wells. If a discharge were to occur, blowdown from the main cooling reservoir would make up the largest percentage of wastewater. A discharge from Outfall 001 would flow to the Colorado River (Colorado River Tidal in Segment 1401 of the Colorado River Basin).
All internal outfalls (Outfalls 101, 201, 401, and 601) discharge to the main cooling reservoir. Outfall 501 would also discharge to the reservoir via Outfall 101, but has not discharge since 1992.
Low Volume Wastewater (Outfalls 101 and 201)
Low volume wastewater results from water treatment operations, boiler blowdown, HVAC blowdown, floor drains, SPCC sources and their associated oily water treatment system discharges, and other miscellaneous sources. Boiler blowdown is from one auxiliary steam boiler, released to reduce impurities in the water that can cause corrosion and boiler tube failure. Service water is demineralized and regeneration of the demineralizer resin beds produces an acidic and caustic wastewater that is treated at the neutralization basins along with boiler blowdown. The floor drain system captures condensate and water from production and maintenance areas that may contain oil or grease, which is then transported to the oily waste treatment system where the oil is separated from the water. The first flush of stormwater from some production and storage areas is also treated in the oily waste system. Other non-processstormwater flow is directed through designated stormwater outfalls.
Treated Domestic Wastewater (Outfalls 401 and 601)
Domestic wastewater is treated onsite in two package treatment systems consisting of aeration, clarification, and disinfection. Car wash water, air conditioning condensate, HVAC cooling tower blowdown, and stormwater are commingled with the domestic wastewater prior to treatment.
Metal Cleaning Waste (Outfall 501)
Metal cleaning waste has not been discharged since 1992. Metal cleaning using chemical or non-chemical liquids produces a waste that would be discharged through Outfall 501 to the neutralization basins (Outfall 101). Stormwater may also be discharge through Outfall 501.
Main Cooling Reservoir (MCR) Relief Well Effluent (Outfolls 002-006)
MCR relief well effluent is collected from the perimeter of the MCR and discharge via Outfall 002-006 without treatment. Outfall 002 is also authorized to discharge demineralized water from Instrumentation.
 
Attachment NOC-AE-14003142 Page 96 of 155 Attachment G Facility Plot Plan Tech Report 1.0- I.e., Pg. 2
 
Attachment NOC-AE-14003142 Page 97 of 155 I                                                      IWA0U IIIM MATAGAM ILDUIA;LrAi COUNIY. 7EXA PLA"I h
                                      )k ATTACNMNTO LEGEND Soulh T~*as I*,dsor Pft qi&#xfd;    mo w  tsvamo
                                                  ~m T~
FACOfrYS so&&US1~
S MTAP l~.r    3m LUnftsI &#xa3;2
                                            &#xfd;w mm              ~'=1 ii  A  OujhILocaflbn                    MET rn-U-----
II  0  knesiAo MwV cib      t  IS-w
 
Attachment NOC-AE-14003142 Page 98 of 155 Attachment H Flow Schematic Diagrams Tech Report 1.0- 2.b., Pg. 3
 
Attachment NOC-AE-14003142 Page 99 of 155 Colorado River SOUTH TEXAS NUCLEAR PLANT MATAGORDA COUNTY, TEXAS Notes:
Outfall has not discharged since March 4, 1997.
ATTACHMENT H
** Outfall has not discharged since December 1992.
FLOW SCHEMATIC - OUTFALL 001 DRAW,/N BY    SSW"LSODI SCALE!                PROJ.          2014TDOES CHECKEDBY:T KOENINGS          De.
b  sRRI      F[LENO. STNoFI..D.o0r,,e..wg APPROVEDBY:            DATEPRINTED DATE:        U, 12,231 A-t S, &#xa3;.dA a
 
Attachment NOC-AE-14003142 Page 100 of 155 Effluent from Relief Wells W1.W125                                  OUTFALL 002 Plant drainage ditch to Colorado River, Tidal Am -
w Demineralized Water from Instrumentation SOUTH TEXAS NUCLEAR PLANT MATAGORDA COUNTY, TEXAS ATTACHMENT H FLOW SCHEMATIC - OUTFALL 002 DRAWANBY:  S,3VLSON SCALE:                    PROJ.            201 4TPDES CHECKEDBY:T KOEWJINDS      Z.. b., -le        FILE NO. SRJI4 Osa APPROVEDBY:          -  DATEPRINTED:
DATE:        M.,t2.2014 t~M 0.,* R*01,g57R.3. 100 2050C*Ol.1 tl Ta,..H~5W*II S0011 I
[ 7R&#xfd;7PS]                      r.n, 7,745 01,140 1.7145 010.51
 
Attachment NOC-AE-14003142..
Page 101 of 155 I      OUTFALL 003 Effluent from Relief Wells  I                    West Branch of the WI 38-W195 W              Colorado River OUTFALL 004 Effluent from Relief Wells    Main Cooling Reservoir W196-W268                      Spillway W
OUTFALL 005 Effluent from Relief Wells          AI        East Fork Little Robbins W269-W483 w                    SloughI OUTFALL 006 Effluent from Relief Wells                        Little Robbins Slough W483-W670 i          -                                a-SOUTH TEXAS NUCLEAR PLANT MATAGORDA COUNTY, TEXAS ATTACHMENT H FLOW SCHEMATIC -OUTFALL 003, 004, 005, 006 DRAM BYA:  SSWMLSON SCALE:              PROJ.            2014WMES CHECKED8Y:TKOENINGB    Se 'br oIP        FILENO.
                                                                                                                    '            LL...l,  '*
APPROVEDI BY          DAE PRINTED:
0  CIA 14 DATE:
0 DV, On. BI44~g2'.DVi 000 0404Cot.S.VTIa.JVOA.,.o.
S~4A Rp&#xfd;S            A4t 70,08 d(2041.7MD 10740 b
 
Attachment NOC-AE-14003142 Page 102 of 155 LOW VOLUME WASTEWATER                                                    recirculation line including wastewater from the following operations and sources:.
* demineralizer regenerant wastewater;
* condenser polishing regenerant wastewater;                                                                                        OUTFALL101
* boiler blowdown;                                                        NEUTRALIZATION BASINS
* boiler drainage;.
* laboratory, instrument, and sampling sources;                                  Neutralization*
I -                  Mixing*
* well water filter backwash; Sedimentation                                                            to Main Cooling
* water softener regenerate; Reservoir
* floor drains in chemical storage containment areas;
* rinse water from triple rinsing empty chemical drums;
,    fuel handling building HVAC blowdown; and
* miscellaneous low volume wastewater.
sludge to landfill Metal Cleaning Waste Effluent                    Storm Water (Outfall 501"*)
SOUTH TEXAS NUCLEAR PLANT MATAGORDA COUNTY, TEXAS Notes:
      'Treatment may be used based on influent quality ATTACHMENT H
        - Outfall 501 has not discharged since December 1992.                                                                  FLOW SCHEMATIC - OUTFALL 101 DRAMIBY:    SSWILSON SCALE.            PR04,          2514TPOES CHECKEDBY:KOENINOS            ,t Be*ba 5cl. FILENO0. GNJS.Y.*Stl,,t APPROVEDB:jS    22  DAT PRINTYED DATE:
I
 
Attachment NOC-AE-14003142 Page 103 of 1556 sludge to incineration and/or landfill
                                                                    -  -  -- w-    filter media to landfill SOUTH TEXAS NUCLEAR PLANT MATAGORDA COUNTY, TEXAS Notes:
ATTACHMENT H
***Treatment process may be used based on influent characteristics.        FLOW SCHEMATIC - OUTFALL 201 SS=tLSON SCAL.E:                PROJ.            2E14TPDES "KOENINGS1  See Sa' cIe          FILENO.      NFSw    ,
                                                                                - DATEPRINTED:          I
                                                                      &#xfd;&#xfd;M 01.5 C..t. A.iObORS,,*bIX 1210C~ftI~4      ShVft~.o r      RPSI            0005170043  P~T0O
 
Attachment NOC-AE-14003142.
Page 104 of 155 AERATION TANKS Activated Sludge Foam Suppression Screening L                  -----------------
OUTFALL 401 DIGESTER Sludge to landfill - --
Aerobic Digestion to Main Cooling Reservoir SOUTH TEXAS NUCLEAR PLANT MATAGORDA COUNTY, TEXAS ATTACHMENT H FLOW SCHEMATIC - OUTFALL 401 DRAMNBY:  SSVVILSONSCALE:          PROJ.        2014ITPDES CHECKED BY:T KOENINOS    S50 b.-.1    ILE NO.
FS~            DThYoa APPROVE BYOR        DATEPRINTED:
DATE:
                                                                                              ~~2          1~-H5,-,.S1 O
monommomwjb&#xfd;
 
Attachment NOC-AE-14003142 Page 105 of 155 OUTFALL 501 Metal Cleaning                                                                  (no discharge since 1992)
Inorganic Basin Wastetwater
                                              --                  Coagulation'                                            to Outfall 101 Chemical Precipitation*
Sedimentation Storm Water SOUTH TEXAS NUCLEAR PLANT MATAGORDA COUNTY, TEXAS ATTACHMENT H FLOW SCHEMATIC - OUTFALL 501 DRAWNBY:    SSW1LSON SCALE                  PROJ.              2014TPOES CHECKEDBY;T KOEtNO1        U0 bar ato S              j FRLENO.      ST._Fl  R- ,.g APPROVEDBY:            - DATEPRINTED; Notes:                                                                                DATE;        Ua. 12.20114
* Treatment process may be used based on influent characteristics.
B.do23I 23,4?.
23* Card,..          2300 42350 CR232323 at 31,50 N00fl. Stat,
                                                                                                                          *a,1431 Faa..00746 i
I        RPS]
 
Attachment NOC-AE-14003142 Page 106 of 155' AERATION TANKS Activated Sludge Foam Suppression Screening OUTFALL 601 DIGESTER Aerobic Digestion I.                                  to Main Cooling Reservoir sludge tolandfill SOUTH TEXAS NUCLEAR PLANT MATAGORDA COUNTY, TEXAS ATTACHMENT H FLOW SCHEMATIC - OUTFALL 601 DRAWNRY:    SD  LSON SCALE:                  PROJ.            2014TPDES CHECKEDBY:T KOEINGS      So.. batbscar      FILENO. STNFl, FIS-ll,.E,.
APPROVEDRY:        -  DATEPR1NTE:
DATE:          0.201              ,*.
                                                                  "TAIML AI      20 a
 
Attachment NOC-AE-14003142 Page 107 of 155 Attachment I Water Treatment Chemicals Tech Report 1.0- 5.c., Pg. 8
 
Attachment NOC-AE-14003142 Page 108 of 155 Treatment Chemicals Product      Manufacturer        Use          Components Listed in    CAS    Frequency of      Toxicity        Product Name                                                    MSDS                          Use          Data      Concentration In MSDS Sodium    ypolorite 7681  3 times per day Univar        :Biocidt                                        for 20 minutes to    Yes      0.15-0.6 ppm total LiquichSor 1310e73-    unit's cooling              residual chlorine Sodium Hydroxide      2            water Sodium nitrite  7632    As needed to              0.25 oz per gallon of 1359 Plus        Nalco  Corrosion inhibitor                        7775                                                                            0          maintain        No    closed cooling system Sodium nictaborate    1      concentration                      water 19H            Nalco  Oxygen scavenger            Hydrazine      302-011-2    Continuous        Yes    0.1 ppm to feedwater Sodium Nitrite  7632    As needed to Nalco  Corrosion inhibitor                            0          maintain        No    500-1500 ppm sodium LCS-60 Sodium Tetraborate 1330    concentration              nitrite concentration 4.
1 935cNlcoNo            Scale            Polyacrylic Acid   N/A         Continuous               0.25 ppm federate as inhibitor/dispersant                                                                       product 3 times per day ACTI-BROM         Nalco         Biocide             Sodium bromide   7647 for 20 minutes to   Yes       0.15-0.6 ppm total.
131.8                                                                 6       unit's cooling               residual chlorine water B-2200         Varichem.     Algaecide             Ethyl Alcohol   64-17-S   Batch treated as     No             5 ppm needed B-2206         Varichem         Biocide           Broimochloro-5.5-   N/A       Continuous       No           0.5-2 ppm diniethylydantoin Scale and SC-23 10       Varichen   coaroaiondinibitor         None listed       N/A       Continuous       No           80-120 ppm
 
Attachment NOC-AE-14003142 Page 109 of 155 Didecyl-Dimethyl-     7173                           4 ppm as product (2.5 H-130M Nalco         Biocide         Ammonium chloride           52/Yr.                   Yes ppm. as active) to aux.
Ethanol           64-17-5                           cooling system for 8
                                                                                                -hours twice per year.
Magnesium Salt         N/A 2-Methyl-4-Isothiazolin 2682     Batch treated as 77352NA Nalco       Isothiazolin               one                 4           needed       Yes         300 ppm 5-Chloro-2-Methyl     26172-
__sothiazolin-3-one 1                              55-4     _                                               1
 
Attachment NOC-AE-14003142 Page 110 of 155 UnIVAR@
Univar USA Inc Material Safety Data Sheet MSDS No:   IOX7668*5 Version No: 010 2014-03-18 Order No;     I ZI Univar USA Inc., 17425 NE Union Hill Rd., Redmond WA 98052 (425) 889 3400 Emergency Assistance For emergency assistance involving chemicals call Chemtrec - (800) 424-9300
 
Attachment NOC-AE-14003142 Page 111 of 155 UNIVAR USA INC.                                                                                                               MSDS NO:OX76685 ISSUE DATE:2011-12-21                                                                                                 VERSION:010 2014-03-18 Annotation:
COMPANY IDENTITY:               Univar                                                                         DATE: 12/21/11 PRODUCT IDENTITY:               Liquichiso     10-16% (Sodium Hypochsorite 10-16%)                             PAGE: 1 OF 8 SAFETY DATA SHEET This Safety Data Sheet conforms to ANSI Z400.5, and to the format requirements and the International Chemical Safety Cards of the Global Harmonizing System.
THIS SOS COMPLIES WITH 29 CFR 1910,1200 (HAZARD COMMUNICATION STANDARD)
IMPORTANT: Read this SOS before handling & disposing of this product.
Pass this information on to employees, customers, & users of this product.
SECTION 1. IDENTIFICATION OF THE SUBSTANCE OR MIXTURE AND OF THE SUPPLIER PRODUCT IDENTITY:             Liquichlor 10-16% (Sodium Hypochlorite 10-16%)
SDS NUMBER:                  OX76685 NEW MSDS DATE:                12/21/2011 COMPANY IDENTITY:            Univar COM1PANY ADDRESS:            17425 NE Union Hill Road COMPANY CITY&#xfd;                Redmond, WA 98052 COMPANY PHONE:                1-425-889-3406 EMERGENCY PHONES:            CHEMTREC: 1-800-424-9300 (USA)
CANUTEC: 1-613-996-6666 (CANADA)
SECTION 2. HAZARDS IDENTIFICATION DANGERI!
EXPOSURE PREVENTION: STRICT HYGIENEI AVOID ALL CONTACTI RISK STATEMENTS:
R35                   Causes severe burns.
RS                   Very toxic to aquatic organisms.
SAFETY STATEMENTS:
SAFETY STATEMENTS:
51/2 Keep locked up-and.out of the reach of children....  
51/2                 Keep locked up-and.out of the reach of children....                                 .....
.........2 4 / 2 5 -&#xfd; ....-A v di d c o n ta ~ t '` w t ' ii n f1' -d_ y le n ..........  
                                              ~    w t ht*' iinf1'
".... ... ....... ........S36/37/39 Wear suitable protective clothing, gloves and eye/face protection.
                      . . .- . A v did c o n ta t '`
526 In case of contact With eyes, rinse immediately with plenty of water and seek medical advice.S28 After contact with skin, wash immediately with plenty of water.S45 In case of accident, or if you feel unwell, seek medical advice immediately. (Show the label where possible).
      .. . .2 4 / 2 5 -&#xfd;                                                      ".... ... . . . . ...........
561 Avoid release to the environment.
                                                                  -d_ y len . .........
Refer to special instructions/safety data sheet.SECTION 3. COM1POSITION/INFORMAATION ON INGREDIENTS MATERIAL Water Sodium Hypochlorite Sodium Hydroxide CAS#7732-18&#xfd;5 7681-52-9 1310-73-2 EINECS#231-791-2 WT %84-98*c 16<= 1.75 Trace components:
S36/37/39             Wear suitable protective clothing, gloves and eye/face protection.
Trace ingredients (if any) are present in 4 1% concentration, (c 0.1% for potential carcinogens, reproductive toxins, respiratory tract mutagens, and sensitizers).
526                   In case of contact With eyes, rinse immediately with plenty of water and seek medical advice.
None of the trace ingredients contribute significant additional hazards at the concentrations present in this product. All pertinent hazard information has been provided in this document, per the requirements of the Federal Occupational Safety and Health Administration Standard (29 CFR 193.6.1200), U.S. State equivalents, and Canadian Hazardous Materials Identification System Standard (CPR 4).SEE SECTIONS 8, 11 8 12 FOR TOXICOLOGICAL INFORMATION.
S28                   After contact with skin, wash immediately with plenty of water.
Attachment NOC-AE-14003142 Page 112 of 155 UNIVAR USA INC. MSDS NO:OX76685 ISSUE DATE:2011-12-21 VERSION:010 2014-03-18 Annotation:
S45                   In case of accident, or if you feel unwell, seek medical advice immediately. (Show the label where possible).
COMPANY IDENTITY:
561                   Avoid release to the environment. Refer to special instructions/safety data sheet.
Univar DATE: 12/21/11 PRODUCT IDENTITY:
SECTION 3. COM1POSITION/INFORMAATION ON INGREDIENTS MATERIAL                                                   CAS#                     EINECS#          WT %
Liquichlor 10-16% (Sodium Hypochlorite 10-16%) PAGE: 2 OF 8 SECTION 4. FIRST AID MEASURES EYE CONTACT: If. this product enters the eyes, open eyes while under gently running water. Use sufficient force: to open eyelids. "Roll" eyes to expose more surface. Minimum flushing is for 15 minutes. Seek immediate medical attention.
Water                                            7732-18&#xfd;5                   231-791-2           84-98 Sodium Hypochlorite                              7681-52-9                                        *c 16 Sodium Hydroxide                                  1310-73-2                                      <= 1.75 Trace components: Trace ingredients (if any) are present in 4 1% concentration, (c 0.1% for potential carcinogens, reproductive toxins, respiratory tract mutagens, and sensitizers). None of the trace ingredients contribute significant additional hazards at the concentrations present in this product. All pertinent hazard information has been provided in this document, per the requirements of the Federal Occupational Safety and Health Administration Standard (29 CFR 193.6.1200), U.S. State equivalents, and Canadian Hazardous Materials Identification System Standard (CPR 4).
SKIN CONTACT: If the product contaminates the skin, immediately begin decontamination with running water. Minimum flushing is for 15 minutes. Remove contaminated clothing, taking care not to contaminate eyes. If skin becomes irritated and irritation persists.
SEE SECTIONS 8, 11 8 12 FOR TOXICOLOGICAL INFORMATION.
medical attention-iffi-e -n--e-f9s-. i discard c0ntaminatid shoes, INHALATION:
 
After high vapor exposure, remove to fresh air. If it is suspected that fumes, are still present, the rescuer should wear an appropriate mask or self-contained breathing apparatus.
Attachment NOC-AE-14003142 Page 112 of 155 UNIVAR USA INC.                                                                             MSDS NO:OX76685 ISSUE DATE:2011-12-21                                                                 VERSION:010 2014-03-18 Annotation:
Keep person warm and at rest. breathing is difficult, give oxygen. If breathing has stopped, trained personnel should immediately begin artificial respiration.
COMPANY IDENTITY:   Univar                                                 DATE: 12/21/11 PRODUCT IDENTITY:   Liquichlor 10-16% (Sodium Hypochlorite 10-16%)         PAGE: 2 OF 8 SECTION 4. FIRST AID MEASURES EYE CONTACT:
It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation.
If.this product enters the eyes, open eyes while under gently running water. Use sufficient force: to open eyelids. "Roll" eyes to expose more surface. Minimum flushing is for 15 minutes. Seek immediate medical attention.
If unconscious, place in recovery position and get medical attention immediately..
SKIN CONTACT:
Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
If the product contaminates the skin, immediately begin decontamination with running water. Minimum flushing is for 15 minutes. Remove contaminated clothing, taking care not to contaminate eyes. If skin becomes irritated and irritation persists. medical attention
If the heart has stopped, trained personnel should immediately begin cardiopulmonary resuscitation (CPR). Seek immediate medical attention.
          -iffi-e-n--e-f9s-. i contaminatea-ch-inle-f*orreuse, discard c0ntaminatid shoes, Wa*-r INHALATION:
In case of inhalation of decomposition products in a fire, symptoms may be delayed.The exposed person may need to be kept under medical surveillance for 48 hours.SWALLOWING:
After high vapor exposure, remove to fresh air. If it is suspected that fumes, are still present, the rescuer should wear an appropriate mask or self-contained breathing apparatus. Keep person warm and at rest. breathing is difficult, give oxygen. If breathing has stopped, trained personnel should immediately begin artificial respiration. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. If unconscious, place in recovery position and get medical attention immediately.. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband. If the heart has stopped, trained personnel should immediately begin cardiopulmonary resuscitation (CPR). Seek immediate medical attention. In case of inhalation of decomposition products in a fire, symptoms may be delayed.The exposed person may need to be kept under medical surveillance for 48 hours.
If swallowed, CALL PHYSICIAN OR POISON CONTROL CENTER FOR MOST CURRENT INFORMATION.
SWALLOWING:
If professional advice is not available, give two glasses of water to drink. DO NOT INDUCE VOMITING.
If swallowed, CALL PHYSICIAN OR POISON CONTROL CENTER FOR MOST CURRENT INFORMATION. If professional advice is not available, give two glasses of water to drink. DO NOT INDUCE VOMITING. Never induce yomiting or give liquids to someone who is unconscious, having convulsions, or unable to swallow. Seek immediate medical attention.
Never induce yomiting or give liquids to someone who is unconscious, having convulsions, or unable to swallow. Seek immediate medical attention.
NOTES TO PHYSICIAN:
NOTES TO PHYSICIAN:
There is no specific antidote.
There is no specific antidote. Treatment of overexposure should be directed at the control
Treatment of overexposure should be directed at the control..m...ri.....  
..                                                                     m...ri.....
.....o..f-.sympdtrs.-andthe.,clinica.ondiionf-thezpatient.
    ..... o..f-.sympdtrs.-andthe.,clinica.ondiionf-thezpatient. Anymatleriaaspirated.!u       in g.   ..
Anymatleriaaspirated.!u  
vomiting may cause lung injury. Therefore, emesis :should not be induced mechanically or pharmacologically. If it is considered necessary to evacuate the stomachlcontents, this should be done by means least likely to cause aspiration (such as: Gastric lavage after endotracheal intubation).
...in g vomiting may cause lung injury. Therefore, emesis :should not be induced mechanically or pharmacologically.
Victims of chemical exposure must be taken for medical attention. Rescuers should be taken for medical attention, if necessary. Take a copy of label and SDS to physician or health professional with victim.
If it is considered necessary to evacuate the stomachlcontents, this should be done by means least likely to cause aspiration (such as: Gastric lavage after endotracheal intubation).
SECTION 5. FIRE FIGHTING MEASURES FIRE & EXPLOSION PREVENTIVE MEASURES Not Applicable.
Victims of chemical exposure must be taken for medical attention.
Rescuers should be taken for medical attention, if necessary.
Take a copy of label and SDS to physician or health professional with victim.SECTION 5. FIRE FIGHTING MEASURES FIRE & EXPLOSION PREVENTIVE MEASURES Not Applicable.
EXTINGUISHING MEDIA Use dry powder, foam, carbon dioxide, water spray, halon, or any "ABC" Class extinguisher.
EXTINGUISHING MEDIA Use dry powder, foam, carbon dioxide, water spray, halon, or any "ABC" Class extinguisher.
SPECIAL FIRE FIGHTING PROCEDURES Water spray may be ineffective on fire but can protect fire-fighters
SPECIAL FIRE FIGHTING PROCEDURES Water spray may be ineffective on fire but can protect fire-fighters
& cool closed containers.
            & cool closed containers. Use fog nozzles if water is used.
Use fog nozzles if water is used.Do not enter confined fire-space without full bunker gear.(Helmet with face shield, bunker coats, gloves & rubber boots).Use NIOSH approved positive-pressure self-contained breathing apparatus.
Do not enter confined fire-space without full bunker gear.
(Helmet with face shield, bunker coats, gloves & rubber boots).
Use NIOSH approved positive-pressure self-contained breathing apparatus.
UNUSUAL EXPLOSION AND FIRE PROCEDURES Noncombustible.
UNUSUAL EXPLOSION AND FIRE PROCEDURES Noncombustible.
Isolate from reducers, acids, wood, organic materials, and most metals.Oxidizer fumes damage lungs. Symptoms may be delayed. Do not breathe fumes.
Isolate from reducers, acids, wood, organic materials, and most metals.
Attachment NOC-AE-14003142 Page 113 of 155 UNIVAR USA INC. MSDS NO:OX76685 ISSUE DATE:2011-12-21 VERSION:010 2014-03-18 Annotation:
Oxidizer fumes damage lungs. Symptoms may be delayed. Do not breathe fumes.
COMPANY IDENTITY:
 
Univar DATE: 12/21/11 PRODUCT IDENTITY:
Attachment NOC-AE-14003142 Page 113 of 155 UNIVAR USA INC.                                                                           MSDS NO:OX76685 ISSUE DATE:2011-12-21                                                               VERSION:010 2014-03-18 Annotation:
Liquichlor 10-16% (Sodium Hypochlorite 10-16%) PAGE: 3 OF 8 SECTION 6. ACCIDENTAL RELEASE MEASURES SPILL AND LEAK RESPONSE AND ENVIRONMENTAL PRECAUTIONS:
COMPANY IDENTITY:     Univar                                                 DATE: 12/21/11 PRODUCT IDENTITY:     Liquichlor 10-16% (Sodium Hypochlorite 10-16%)         PAGE: 3 OF   8 SECTION 6. ACCIDENTAL RELEASE MEASURES SPILL AND LEAK RESPONSE AND ENVIRONMENTAL PRECAUTIONS:
Uncontrolled releases should be responded to by trained personnel using pre-planned procedures.
Uncontrolled releases should be responded to by trained personnel using pre-planned procedures. Proper protective equipment should be used. In case of a spill, clear the affected area, protect people, and respond with trained personnel.
Proper protective equipment should be used. In case of a spill, clear the affected area, protect people, and respond with trained personnel.
PERSONAL PROTECTIVE EQUIPMENT The proper personal protective equipment for incidental releases (such as: I Liter of the product released in a well-ventilated area), use impermeable gloves (triple-gloves (rubber gloves and nitrile gloves, over latex gloves), goggles, face shield, and appropriate body
PERSONAL PROTECTIVE EQUIPMENT The proper personal protective equipment for incidental releases (such as: I Liter of the product released in a well-ventilated area), use impermeable gloves (triple-gloves (rubber gloves and nitrile gloves, over latex gloves), goggles, face shield, and appropriate body-ent-o"--arge-4elea se-use-impermeab1e-flve~s-spec-iic-for-the material handled, chemically resistant suit and boots, and hard hat. Self-Contained Breathing Apparatus or respirator may be required where engineering controls are not adequate or conditions for potential exposure exist. When respirators are required, select NIOSH/MSHA approved based on actual or potential airborne concentrations in accordance with latest OSHA and/or ANSI recommendations.
_pr-tectitn*-In-the -ent-o"--arge-4elea se-use-impermeab1e-flve~s-spec-iic-for- the material handled, chemically resistant suit and boots, and hard hat. Self-Contained Breathing Apparatus or respirator may be required where engineering controls are not adequate or conditions for potential exposure exist. When respirators are required, select NIOSH/MSHA approved based on actual or potential airborne concentrations in accordance with latest OSHA and/or ANSI recommendations.
ENVIRONMENTAL PRECAUTIONS:
ENVIRONMENTAL PRECAUTIONS:
Stop spill at source. Construct temporary dikes of dirt, sand, or any appropriate readily available material to prevent spreading of the material.
Stop spill at source. Construct temporary dikes of dirt, sand, or any appropriate readily available material to prevent spreading of the material. Close or cap valves and/or block or plug hole in leaking container and transfer to another container. Keep from entering storm sewers and ditches which lead to waterways, and if necessary, call the local fire or police department for immediate emergency assistance.
Close or cap valves and/or block or plug hole in leaking container and transfer to another container.
CONTAINMENT AND CLEAN-UP MEASURES:
Keep from entering storm sewers and ditches which lead to waterways, and if necessary, call the local fire or police department for immediate emergency assistance.
Absorb spilled liquid with polypads or other suitable absorbent materials. if necessary,'
CONTAINMENT AND CLEAN-UP MEASURES: Absorb spilled liquid with polypads or other suitable absorbent materials.
neutralize using suitable buffering material, (acid with soda ash or base with phosphoric acid), and test area with litmus paper to confirm neutralization. Clean up with non-combustible absorbent (suchas: sand, soil, and so on). Shovel up and place all spill residue in suitable containers, dispose of at an appropriate waste disposal facility according to current applicable laws and regulations and product characteristics at time of disposal (see Section 13 - Disposal Considerations).
if necessary,'
SECTION 7. HANDLING AND STORAGE HANDLING Use only with adequate ventilation. Do not get in eyes, on skin or clothing.
neutralize using suitable buffering material, (acid with soda ash or base with phosphoric acid), and test area with litmus paper to confirm neutralization.
Wear OSHA Standard full face shield. Consult Safety Equipment Supplier. Wear goggles, face shield, gloves, apron & footwear impervious to material. Wash clothing before reuse, NEVER pour water into this substance. When dissolving or diluting, always add it slowly to the water.
Clean up with non-combustible absorbent (suchas: sand, soil, and so on). Shovel up and place all spill residue in suitable containers, dispose of at an appropriate waste disposal facility according to current applicable laws and regulations and product characteristics at time of disposal (see Section 13 -Disposal Considerations).
To minimize static discharge when transferring, ensure electrical continuity by bonding and grounding all equipment. Use an inlet line diameter of at least 3.5 inches (8.9 centimeters) with a maximum flow rate of I meter/second.
SECTION 7. HANDLING AND STORAGE HANDLING Use only with adequate ventilation.
STORAGE Keep separated from strong oxidants, strong acids, combustible & reducing substances, metals, food & feedstuffs. Keep cool. Keep dry. Keep in the dark. See: Section 10, (Materials to Avoid>. Do not store above 49 C/120 F. Keep container tightly closed
Do not get in eyes, on skin or clothing.Wear OSHA Standard full face shield. Consult Safety Equipment Supplier.
          & upright when not in use to prevent leakage.
Wear goggles, face shield, gloves, apron & footwear impervious to material.
Wear full face shield, gloves & full protective clothing when opening or handling.
Wash clothing before reuse, NEVER pour water into this substance.
When empty, drain completely, replace bungs securely.
When dissolving or diluting, always add it slowly to the water.To minimize static discharge when transferring, ensure electrical continuity by bonding and grounding all equipment.
NONBULK: CONTAINERS:
Use an inlet line diameter of at least 3.5 inches (8.9 centimeters) with a maximum flow rate of I meter/second.
Store containers in a cool, dry location, away from direct sunlight, sources of intense heat, or where freezing is possible. Material should be stored in secondary containers or in a -diked area, as appropriate. Store containers away from incompatible chemicals (see Section 10, Stability and Reactivity). Post warning and "NO SMOKING" signs in storage and use areas, as appropriate. Empty containers should be handled with care. Never store food, feed, or drinking water in containers which held this product.
STORAGE Keep separated from strong oxidants, strong acids, combustible  
BULK CONTAINERS:
& reducing substances, metals, food & feedstuffs.
Keep cool. Keep dry. Keep in the dark. See: Section 10, (Materials to Avoid>. Do not store above 49 C/120 F. Keep container tightly closed& upright when not in use to prevent leakage.Wear full face shield, gloves & full protective clothing when opening or handling.When empty, drain completely, replace bungs securely.NONBULK: CONTAINERS:
Store containers in a cool, dry location, away from direct sunlight, sources of intense heat, or where freezing is possible.
Material should be stored in secondary containers or in a -diked area, as appropriate.
Store containers away from incompatible chemicals (see Section 10, Stability and Reactivity).
Post warning and "NO SMOKING" signs in storage and use areas, as appropriate.
Empty containers should be handled with care. Never store food, feed, or drinking water in containers which held this product.BULK CONTAINERS:
All tanks and pipelines which contain this material must be labeled. Perform routine maintenance on tanks or pipelines which contain this product. Report all leaks immediately to the proper personnel.
All tanks and pipelines which contain this material must be labeled. Perform routine maintenance on tanks or pipelines which contain this product. Report all leaks immediately to the proper personnel.
Attachment NOC-AE-14003142 Page 114 of 155 UNIVAR USA INC. MSDS NO:OX76685 ISSUE DATE:2011-12-21 VERSION:010 2014-03-18 Annotation:
 
COMPANY IDENTITY:
Attachment NOC-AE-14003142 Page 114 of 155 UNIVAR USA INC.                                                                                               MSDS NO:OX76685 ISSUE DATE:2011-12-21                                                                               VERSION:010 2014-03-18 Annotation:
Univar DATE: 12/21/11 PRODUCT IDENTITY:
COMPANY IDENTITY:       Univar                                                             DATE: 12/21/11 PRODUCT IDENTITY:       Liquichlor 10-16% (Sodium Hypochlorite 10-16%)                     PAGE: 4     OF 8 SECTION 7. HANDLING AND STORAGE (CONTINUED)
Liquichlor 10-16% (Sodium Hypochlorite 10-16%) PAGE: 4 OF 8 SECTION 7. HANDLING AND STORAGE (CONTINUED)
TANK CAR SHIPMENTS:
TANK CAR SHIPMENTS:
Tank cars carrying this product should be loaded and unloaded in strict accordance with tank-car manufacturer's recommendation and all established on-site safety procedures.
Tank cars carrying this product should be loaded and unloaded in strict accordance with tank-car manufacturer's recommendation and all established on-site safety procedures.
Appropriate personal protective equipment must be used (see Section 8, Engineering Controls and Personal Protective Equipment.).
Appropriate personal protective equipment must be used (see Section 8, Engineering Controls and Personal Protective Equipment.). All loading and unloading equipment must be inspected, prior to each use. Loading and unloading operations must be attended, at all times. Tank cares must be level, brakes must be set or wheels must be locked or blocked prior to loading or unloading. Tank car (for loading) or storage tanks (for unloading)
All loading and unloading equipment must be inspected, prior to each use. Loading and unloading operations must be attended, at all times. Tank cares must be level, brakes must be set or wheels must be locked or blocked prior to loading or unloading.
  ------    must   be verified to be correct for receiving this rier*-to-s-t-ai~ting-the-transfer-o.                        product and be properly n-ch--ppe
Tank car (for loading) or storage tanks (for unloading) must be verified to be correct for receiving this product and be properly prepared,------
                                                                      ;-*~rH~e-mast---*e-verJt+      prepared, t positions, before starting transfer operations. A sample (if required) must be taken and verified (if required) prior to starting transfer operations. All lines must be blown-down and purged before disconnecting them from the tank car or vessel.
n-ch--ppe t positions, before starting transfer operations.
PROTECTIVE PRACTICES DURING MAINTENANCE OF CONTAMINATED EQUIPMENT:
A sample (if required) must be taken and verified (if required) prior to starting transfer operations.
Follow practices indicated in Section 6 (Accidental Release Measures). Make certain application equipment is locked and tagged-out safely. Always use this product in areas where adequate ventilation is provided. Collect all rinsates and dispose of according to applicable Federal, State, or local procedures.
All lines must be blown-down and purged before disconnecting them from the tank car or vessel.PROTECTIVE PRACTICES DURING MAINTENANCE OF CONTAMINATED EQUIPMENT:
SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION MATERIAL                                       CAS#       EINECS#   TWA (OSHA)       TLV (ACGIH)
Follow practices indicated in Section 6 (Accidental Release Measures).
Water                                 7732-18-5       231-791-2   None Known       None Known Sodium Hydroxide                     1310-73-2           -       2 mg/m3           None known Sodium Hypochlorite                   7681-52-9           -       None Known       None Known MATERIAL                               CAS#       EINECS#     CEILING   STEL(OSHA/ACGIH)     HAP Sodium Hydroxide                 1310-73-2         -         2 mg/m3         None Known       No This product contains no EPA Hazardous Air Pollutants (HAP)               in amounts > 0.1%.
Make certain application equipment is locked and tagged-out safely. Always use this product in areas where adequate ventilation is provided.
RESPIRATORY EXPOSURE CONTROLS b l&ti 65&#xfd;00'su-re lmits . .iVen 51Y6Ve- .-I respiratory protection is needed, use only protection authorized in 29 CFR 1910.134, European Standard EN 149, or applicable State regulations. If adequate ventilation is not available or there is potential for airborne exposure above the exposure limits, a respirator may be worn up to the respirator exposure limitations, check with respirator equipment manufacturer's recommendations/limitations. For a higher level of protection, use positive pressure supplied air respiration protection or Self Contained Breathing Apparatus or if oxygen levels are below i9.5%or are unknown.
Collect all rinsates and dispose of according to applicable Federal, State, or local procedures.
EMERGENCY OR PLANNED ENTRY INTO UNKNOWN CONCENTRATIONS OR IDLH CONDITIONS Positive pressure, full-face piece Self Contained Breathing Apparatus; or positive pressure, full-face piece Salf Contained Breathing Apparatus with an auxilliary positive pressure Self Contained Breathing Apparatus..
SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION MATERIAL CAS# EINECS# TWA (OSHA) TLV (ACGIH)Water 7732-18-5 231-791-2 None Known None Known Sodium Hydroxide 1310-73-2  
VENTILATION LOCAL EXHAUST:       Necessary             MECHANICAL (GENERAL):       Necessary SPECIAL:             None                   OTHER:                       None Please refer to ACGIH document, "Industrial Ventilation, A Manual of Recommended Practices", most. recent edition, for detailsi EYE PROTECTION:
-2 mg/m3 None known Sodium Hypochlorite 7681-52-9  
            -Splash goggles or safety glasses. Face-shields are recommended when the operation can generate splashes, sprays or mists.
-None Known None Known MATERIAL CAS# EINECS# CEILING STEL(OSHA/ACGIH)
HAND PROTECTION:
HAP Sodium Hydroxide 1310-73-2  
-2 mg/m3 None Known No This product contains no EPA Hazardous Air Pollutants (HAP) in amounts > 0.1%.RESPIRATORY EXPOSURE CONTROLS b l&ti 65&#xfd;00'su-re lmits ..i Ven 51Y6Ve- .-I respiratory protection is needed, use only protection authorized in 29 CFR 1910.134, European Standard EN 149, or applicable State regulations.
If adequate ventilation is not available or there is potential for airborne exposure above the exposure limits, a respirator may be worn up to the respirator exposure limitations, check with respirator equipment manufacturer's recommendations/limitations.
For a higher level of protection, use positive pressure supplied air respiration protection or Self Contained Breathing Apparatus or if oxygen levels are below i9.5% or are unknown.EMERGENCY OR PLANNED ENTRY INTO UNKNOWN CONCENTRATIONS OR IDLH CONDITIONS Positive pressure, full-face piece Self Contained Breathing Apparatus; or positive pressure, full-face piece Salf Contained Breathing Apparatus with an auxilliary positive pressure Self Contained Breathing Apparatus..
VENTILATION LOCAL EXHAUST: Necessary MECHANICAL (GENERAL):
Necessary SPECIAL: None OTHER: None Please refer to ACGIH document, "Industrial Ventilation, A Manual of Recommended Practices", most. recent edition, for detailsi EYE PROTECTION:-Splash goggles or safety glasses. Face-shields are recommended when the operation can generate splashes, sprays or mists.HAND PROTECTION:
Wear appropriate impervious gloves for routine industrial use. Use impervious gloves for spill response, as stated in Section 6 of this SDS (Accidental Release Measures).
Wear appropriate impervious gloves for routine industrial use. Use impervious gloves for spill response, as stated in Section 6 of this SDS (Accidental Release Measures).
Attachment NOC-AE-14003142 Page 115 of 155 UNIVAR USA INC. MSDS NO:OX76685 ISSUE DATE:2011-12-21 VERSION:010 2014-03-18 Annotation:
 
COMPANY IDENTITY:
Attachment NOC-AE-14003142 Page 115 of 155 UNIVAR USA INC.                                                                             MSDS NO:OX76685 ISSUE DATE:2011-12-21                                                               VERSION:010 2014-03-18 Annotation:
Univar DATE: 12/21/11 PRODUCT IDENTITY:
COMPANY IDENTITY:   Univar                                                   DATE: 12/21/11 PRODUCT IDENTITY:   Liquichlor 10-16% (Sodium Hypochlorite 10-16%)           PAGE: 5 OF   8 SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION (CONTINUED)
Liquichlor 10-16% (Sodium Hypochlorite 10-16%) PAGE: 5 OF 8 SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION (CONTINUED)
NOTICE: The selection of a specific glove for a particular application and duration of use in a.workplace should also take into account all relevant workplace factors such as, but not limited to: Other chemicals which may be handled, physical requirements (cut/puncture protection, dexterity, thermal protection), potential body reactions to glove materials, as well as the instructions/specifications provided by the glove supplier.
NOTICE: The selection of a specific glove for a particular application and duration of use in a. workplace should also take into account all relevant workplace factors such as, but not limited to: Other chemicals which may be handled, physical requirements (cut/puncture protection, dexterity, thermal protection), potential body reactions to glove materials, as well as the instructions/specifications provided by the glove supplier.BODY PROTECTION:
BODY PROTECTION:
Use body protection appropriate for task. Cover-all, rubber aprons, or chemical protective.clothing made from impervious materials are generally acceptable, depending on the task.WORK & HYGIENIC PRACTICES:
Use body protection appropriate for task. Cover-all, rubber aprons, or chemical protective
Provide readily accesslble eye wash stations &"'safety showers.Wash at end of each workshift  
        .clothing made from impervious materials are generally acceptable, depending on the task.
& before eating, smoking or using the toilet.Promptly remove clothing that becomes contaminated.
WORK & HYGIENIC PRACTICES:
Destroy contaminated leather articles.
Provide readily accesslble eye wash stations &"'safety showers.
Launder or discard contaminated clothing.SECTION 9. PHYSICAL & CHEMICAL PROPERTIES APPEARANCE:
Wash at end of each workshift & before eating, smoking or using the toilet.
Liquid, Clear, Yellow to Yellow-Green ODOR: Chlorine-like, Pungent ODOR THRESHOLD:
Promptly remove clothing that becomes contaminated. Destroy contaminated leather articles. Launder or discard contaminated clothing.
0.3 ppm (detection), for Chlorine pH (Neutrality):
SECTION 9. PHYSICAL & CHEMICAL PROPERTIES APPEARANCE:                                         Liquid, Clear, Yellow to Yellow-Green ODOR:                                               Chlorine-like, Pungent ODOR THRESHOLD:                                     0.3 ppm (detection), for Chlorine pH (Neutrality):                                     12 - 14 (1%.Solution)_
12 -14 (1%.Solution)_
MELTING POINT/FREEZING POINT:                       -27 C / -17 F BOILING RANGE (IBP,5.0%,Dry Point):                 140 C / 284 F FLASH POINT .(TEST METHOD):                         Not Applicable EVAPORATION RATE (n-BUTYL ACETATE=I):               Not Applicable FLAMMABILITY CLASSIFICATION:                         Non-Combustible LOWER FLAYUMABLE LIMIT IN AIR (% by vol):           Not Applicable UPPER FLA&MABLE LIMIT IN AIR (%by vol):             Not Available VAPOR PRESSURE (mm of Hg)@20 C                       12 (12.5% Solution)
MELTING POINT/FREEZING POINT: -27 C / -17 F BOILING RANGE (IBP,5.0%,Dry Point): 140 C / 284 F FLASH POINT .(TEST METHOD): Not Applicable EVAPORATION RATE (n-BUTYL ACETATE=I):
VAPOR DENSITY (air=l):                             .0.670 GRAVITY @ 68/68 F / 20/20 C:
Not Applicable FLAMMABILITY CLASSIFICATION:
SPECIFIC GRAVITY (Water=l):                     1.17 - 1,22 POUNDS/GALLON:                                   9.75 - 10.20 PARTITION COEFFICIENT (n-Octane/Water):             Not Available AUTO IGNITION TEMPERATURE:                         Not Applicable DECOMPOSITION   TEMPERATURE:                       Not Available VOC'S (>e,44 Lbs/Sq In) :                           0.0 Vol% /0.0 g/L / 0.000 Lbs/Gal TOTAL VOC'S (TVOC)*:                               0.0 Vol% /0.0 g/L / 0.000 Lbs/Gal NONEXEMPT VOC'S (CVOC)*:                           0.0 Vol% /0.0 g/L / 0.000 Lbs/Gal HAZARDOUS AIR POLLUTANTS (HAPS):                   8.8 Wt9 /0.0 g/L / 0.000 Lbs/Gal NONEXEMPT VOC PARTIAL PRESSURE (mm of Hg Q 20 C) 0.0 Using California South Coast Air Quality Management District (SCAQMD) Rule 443.1.
Non-Combustible LOWER FLAYUMABLE LIMIT IN AIR (% by vol): Not Applicable UPPER FLA&MABLE LIMIT IN AIR (% by vol): Not Available VAPOR PRESSURE (mm of Hg)@20 C 12 (12.5% Solution)VAPOR DENSITY (air=l): .0.670 GRAVITY @ 68/68 F / 20/20 C: SPECIFIC GRAVITY (Water=l):
SECTION 10. STABILITY & REACTIVITY STABILITY Stable under normal conditions.
1.17 -1,22 POUNDS/GALLON:
9.75 -10.20 PARTITION COEFFICIENT (n-Octane/Water):
Not Available AUTO IGNITION TEMPERATURE:
Not Applicable DECOMPOSITION TEMPERATURE:
Not Available VOC'S (>e,44 Lbs/Sq In) : 0.0 Vol% /0.0 g/L / 0.000 Lbs/Gal TOTAL VOC'S (TVOC)*: 0.0 Vol% /0.0 g/L / 0.000 Lbs/Gal NONEXEMPT VOC'S (CVOC)*: 0.0 Vol% /0.0 g/L / 0.000 Lbs/Gal HAZARDOUS AIR POLLUTANTS (HAPS): 8.8 Wt9 /0.0 g/L / 0.000 Lbs/Gal NONEXEMPT VOC PARTIAL PRESSURE (mm of Hg Q 20 C) 0.0 Using California South Coast Air Quality Management District (SCAQMD) Rule 443.1.SECTION 10. STABILITY  
& REACTIVITY STABILITY Stable under normal conditions.
CONDITIONS TO AVOID Isolate from extreme temperatures and incompatible chemicals.
CONDITIONS TO AVOID Isolate from extreme temperatures and incompatible chemicals.
MATERIALS TO AVOID Reacts violently with fire extinguishers containing water. The substance is a strong base, reacts violently with acids and is corrosive.
MATERIALS TO AVOID Reacts violently with fire extinguishers containing water. The substance is a strong base, reacts violently with acids and is corrosive. Decomposes on heating and on contact with strong acids, (such as sulfuric acid) producing, toxic & corrosive fumes including, chlorine, phosgene, & hydrogen chloride. The. substance is a strong oxidant & reacts violently with combustible & reducing materials. Reacts with water generating sufficient heat to ignite combustible materials. Reacts violently with strong acids, causing fire &
Decomposes on heating and on contact with strong acids, (such as sulfuric acid) producing, toxic & corrosive fumes including, chlorine, phosgene, & hydrogen chloride.
explosion hazard. Attacks many plastics, rubber, coatings, many metals, such as aluminum,
The. substance is a strong oxidant & reacts violently with combustible  
        .zinc, tin, & lead. forming flammable/explosive gas (hydrogen).
& reducing materials.
Reacts with ammonium salts to produce ammonia & causing fire hazard.
Reacts with water generating sufficient heat to ignite combustible materials.
Rapidly absorbs carbon dioxide & water from the air.
Reacts violently with strong acids, causing fire &explosion hazard. Attacks many plastics, rubber, coatings, many metals, such as aluminum,.zinc, tin, & lead. forming flammable/explosive gas (hydrogen).
 
Reacts with ammonium salts to produce ammonia & causing fire hazard.Rapidly absorbs carbon dioxide & water from the air.
Attachment NOC-AE-14003142 Page 116 of 155 UNIVAR USA INC.                                                                             MSDS NO:OX76685 ISSUE DATE:2011-12-21                                                               VERSION:010 2014-03-18 Annotation:
Attachment NOC-AE-14003142 Page 116 of 155 UNIVAR USA INC. MSDS NO:OX76685 ISSUE DATE:2011-12-21 VERSION:010 2014-03-18 Annotation:
COMPANY IDENTITY:         Univar                                             DATE: 12/21/11 PRODUCT IDENTITY:         Liquichlor 10-16% (Sodium Hypochlorite 10-16%)     PAGE: 6 OF 8 SECTION 10. STABILITY & REACTIVITY (CONTINUED)
COMPANY IDENTITY:
HAZARDOUS DECOMPOSITION PRODUCTS Hydrogen Chloride, Phosgene, Sodium Oxide & Hydroxide from heating.
Univar DATE: 12/21/11 PRODUCT IDENTITY:
HAZARDOUS POLYMERIZATION Will not occur.
Liquichlor 10-16% (Sodium Hypochlorite 10-16%) PAGE: 6 OF 8 SECTION 10. STABILITY  
SECTION 11. TOXICOLOGICAL INFORMATION ACUTE HAZARDS EYE &   K-FKN--CON'TA-T:
& REACTIVITY (CONTINUED)
HAZARDOUS DECOMPOSITION PRODUCTS Hydrogen Chloride, Phosgene, Sodium Oxide & Hydroxide from heating.HAZARDOUS POLYMERIZATION Will not occur.SECTION 11. TOXICOLOGICAL INFORMATION ACUTE HAZARDS EYE & K-FKN--CON'TA-T:
Severe burns to skin, defatting, dermatitis.
Severe burns to skin, defatting, dermatitis.
Severe burns to eyes, redness, tearing, blurred vision.Liquid can cause severe skin & eye burns. Wash thoroughly after handling.INHALATION:
Severe burns to eyes, redness, tearing, blurred vision.
Severe respiratory tract irritation may occur. Vapor harmful. The applicable occupational exposure limit value should not be exceeded during any part of the working exposure.SWALLCWING:
Liquid can cause severe skin & eye burns. Wash thoroughly after handling.
INHALATION:
Severe respiratory tract irritation may occur. Vapor harmful. The applicable occupational exposure limit value should not be exceeded during any part of the working exposure.
SWALLCWING:
Harmful or fatal if swallowed.
Harmful or fatal if swallowed.
SUBCHRONIC HAZARDS/CONDITIONS AGGRAVATED CONDITIONS AGGRAVATED:
SUBCHRONIC HAZARDS/CONDITIONS AGGRAVATED CONDITIONS AGGRAVATED:
Sodiumn Hypochlorite, a component of this product, is a sensitizer.
Sodiumn Hypochlorite, a component of this product, is a sensitizer. Prolonged or repeated skin contact can result in the development of rashes, welts, and other allergy-like symptoms.
Prolonged or repeated skin contact can result in the development of rashes, welts, and other allergy-like symptoms.CHRONIC HAZARDS CANCER, REPRODUCTIVE  
CHRONIC HAZARDS CANCER, REPRODUCTIVE & OTHER CHRONIC HAZARDS:
& OTHER CHRONIC HAZARDS: This product has no carcinogens listed by IARC, NTP, NIOSH, OSHA or ACGIH, as of this date,..gpreeater rqual to 0.1%. ...MUTAGENICITY:
This product has no carcinogens listed by IARC, NTP, NIOSH, OSHA or ACGIH, as of this date,..gpreeater rqual to 0.1%.               ...
This product is not reported to produce mutagenic effects in humans.Human mutation data are available for Sodium Hypochlorite (a component of this product);these data were obtained during clinical studies involving specific tissues exposed to relatively high concentrations of this substance.
MUTAGENICITY: This product is not reported to produce mutagenic effects in humans.
Mutation data, obtained during clinical studies on test animal tissues or micro-organisms are available for Potassium Hydroxide.
Human mutation data are available for Sodium Hypochlorite (a component of this product);
EMBRYOTOXICITY:
these data were obtained during clinical studies involving specific tissues exposed to relatively high concentrations of this substance. Mutation data, obtained during clinical studies on test animal tissues or micro-organisms are available for Potassium Hydroxide.
This product is not reported to produce embryotoxic effects in humans.TERATOGENICITY:
EMBRYOTOXICITY: This product is not reported to produce embryotoxic effects in humans.
This product is not reported to produce teratogenic effects in humans.REPRODUCTIVE TOXICITY:
TERATOGENICITY: This product is not reported to produce teratogenic effects in humans.
This product is not reported to cause reproductive effects in humans.A mutaen is a chemical which causes permanent changes "to genetic material (DNA) such that the changes will propagate through generational lines. An embrvotoxin is a chemical which causes damage to a developing embryo (such as: within the eight weeks of pregnancy in humans), but the damage does not propagate across generational lines. A teratogen is a chemical which causes damage to a developing fetus, but the damage does no-tpropagate across generational lines. A reproductive toxin is any substance which interferes in any way with the reproductive process.MAMMALIAN TOXICITY INFORMATION SODIUM HYDROXIDE:
REPRODUCTIVE TOXICITY: This product is not reported to cause reproductive effects in humans.
Eye irritancy (monkey):
A mutaen is a chemical which causes permanent changes "to genetic material (DNA) such that the changes will propagate through generational lines. An embrvotoxin is a chemical which causes damage to a developing embryo (such as: within the eight weeks of pregnancy in humans), but the damage does not propagate across generational lines. A teratogen is a chemical which causes damage to a developing fetus, but the damage does no-tpropagate across generational lines. A reproductive toxin is any substance which interferes in any way with the reproductive process.
1%, 24 hours (severe)Eye irritancy (rabbit):
MAMMALIAN TOXICITY INFORMATION SODIUM HYDROXIDE:
500 ml, 24 hours (severe)Eye irritancy (rabbit):
Eye irritancy (monkey):               1%, 24 hours (severe)
1% solution (severe)Eye irrItancy (rabbit):
Eye irritancy (rabbit):               500 ml, 24 hours (severe)
I .mg, 24 hours (severe)Cytogenic analysis system (grasshopper parenteral):
Eye irritancy (rabbit):               1% solution (severe)
20 mg LD50 (interperoneal, mouse): 48 mg/kg LDLo (oral, rabbit): 500 mg/kg Attachment NOC-AE-14003142 Page 117 of 155 UNIVAR USA INC. MSDS NO:OX76685 ISSUE DATE:2011-12-21 VERSION:010 2014-03-18 Annotation:
Eye irrItancy (rabbit):               I .mg, 24 hours (severe)
COMPANY IDENTITY:
Cytogenic analysis system (grasshopper parenteral): 20 mg LD50 (interperoneal, mouse):         48 mg/kg LDLo (oral, rabbit):                 500 mg/kg
Univar DATE: 12/21/11 PRODUCT IDENTITY:
 
Liquichlor 10-16% (Sodium Hypochlorite l1-16%) PAGE: 7 OF 8 SECTION 11. TOXICOLOGICAL INFORMATION (CONTINUED).
Attachment NOC-AE-14003142 Page 117 of 155 UNIVAR USA INC.                                                                                                     MSDS NO:OX76685 ISSUE DATE:2011-12-21                                                                                       VERSION:010 2014-03-18 Annotation:
COMPANY IDENTITY:       Univar                                                                     DATE: 12/21/11 PRODUCT IDENTITY:       Liquichlor 10-16% (Sodium Hypochlorite l1-16%)                             PAGE: 7 OF 8 SECTION 11. TOXICOLOGICAL INFORMATION (CONTINUED).
MAMMALIAN TOXICITY INFORMATION (CONTINUED)
MAMMALIAN TOXICITY INFORMATION (CONTINUED)
SODIUM HYPOCHLORITE:
SODIUM HYPOCHLORITE:
Eye effects (Adult Rabbit): Moderate irritation effects.Microsomal Mutageniticity Assay (Salmonella typhimunium):
Eye effects (Adult Rabbit): Moderate irritation effects.
1 mg/plate Cytogenetic Analysis (Human): Lymphocyte, ie0 ppm/24 hours.TDLo, Oral (woman): I g/kg, Central nervous system effects, blood pressure effects TDLo, Intravenous (Man): 45 mg/kg, Pulmonary system , LD50 (Oral, Mouse): 5800 mg/kg.--.--.--S -SECT1ON-12E COLOGICAL-INFORt4AT-ION ALL WORK PRACTICES MUST BE AIMED AT ELIMINATING ENVIRONMENTAL CONTAMINATION.
Microsomal Mutageniticity Assay (Salmonella typhimunium): 1 mg/plate Cytogenetic Analysis (Human): Lymphocyte, ie0 ppm/24 hours.
EFFECT OF MATERIAL ON PLANTS OR ANIMALS: This product may be harmful or fatal to plant and animal life if released into the environment.
TDLo, Oral (woman): I g/kg, Central nervous system effects, blood pressure effects TDLo, Intravenous (Man): 45 mg/kg, Pulmonary system , LD50 (Oral, Mouse): 5800 mg/kg S                 -SECT1ON-12ECOLOGICAL-INFORt4AT-ION ALL WORK   PRACTICES MUST BE AIMED AT ELIMINATING ENVIRONMENTAL CONTAMINATION.
Refer to Section 11 (Toxicological Information) for further data on the effects of this product's components on test animals.EFFECT OF MATERIAL ON AQUATIC LIFE: LCSB (Bluegill sunfish):
EFFECT OF MATERIAL ON PLANTS OR ANIMALS:
2.90 mg/L/96 hours LC50 (Pimephales promelas):
This product may be harmful or fatal to plant and animal life if released into the environment. Refer to Section 11 (Toxicological Information) for further data on the effects of this product's components on test animals.
1.40 mg/L/96 hours LCS5 (Oncorhynchus mykiss): 0.90 mg/L/0.5 hours The substance is toxic to aquatic organisms.
EFFECT OF MATERIAL ON AQUATIC LIFE:
LCSB (Bluegill sunfish):                   2.90 mg/L/96 hours LC50 (Pimephales promelas):               1.40 mg/L/96 hours LCS5 (Oncorhynchus mykiss):               0.90 mg/L/0.5 hours The substance is toxic to aquatic organisms.
The substance may be hazardous in the environment, Special attention should be given to water organisms.
The substance may be hazardous in the environment, Special attention should be given to water organisms.
MOBILITY IN SOIL Mobility of this material has not been determined.
MOBILITY IN SOIL Mobility of this material has not been determined.
DEGRADABILITY This product is completely biodegradable.-ACCUMULAT ION -................  
DEGRADABILITY This product is completely biodegradable.
........ ................  
      -ACCUMULAT ION -   ................                                 .   . .....
...... ---------Bloaccumulation of this product has not been determined.
Bloaccumulation of this product has not been determined.
SECTION 13. DISPOSAL CONSIDERATIONS Processing, use or contamination may change the waste management options.Recycle / dispose of observing national, regional, state, provincial and local health, safety & pollution laws. If in doubt, contact appropriate agencies.SECTION 14. TRANSPORT INFORMATION IF > 625 LB / 284 KG OF. THIS PRODUCT IN I CONTAINER, IT EXCEEDS THE "RQ" OF SODIUM HYPOCHLORITE.
SECTION 13. DISPOSAL CONSIDERATIONS Processing, use or contamination may change the waste management options.
DOT SHIPPING NAME: UN1791, Hypochlorite Solutions, B, PG-Irl DRUM LABEL: (CORROSIVE)
Recycle / dispose of observing national, regional, state, provincial and local health, safety & pollution laws.               If in doubt, contact appropriate agencies.
EMERGENCY RESPONSE GUIDEBOOK NUMBER: 154 Attachment NOC-AE-14003142 Page 118 of 155 UNIVAR USA I NC. MSDS NO:OX76685 ISSUE DATE:201 1-12-21 VERSION:010 2014-03-18 Annotation:
SECTION 14. TRANSPORT INFORMATION IF > 625 LB / 284 KG OF. THIS PRODUCT IN I CONTAINER, IT EXCEEDS THE "RQ" OF SODIUM HYPOCHLORITE.
COMPANY IDENTITY:
DOT SHIPPING NAME: UN1791, Hypochlorite Solutions, B, PG-Irl DRUM LABEL:               (CORROSIVE)
Univar DATE: 12/21/11 PRODUCT IDENTITY:
EMERGENCY RESPONSE GUIDEBOOK NUMBER: 154
OX76685 PAGE: 8 OF 8 SECTION 15. REGULATORY INFORMATION EPA REGULATION:
 
SARA SECTION 311/312 HAZARDS: Acute Health All components of this product are on the TSCA list, This material contains no known products restricted under SARA Title III, Section 313 in amounts greater or equal to 1%.SARA TITLE III INGREDIENTS CAS# EINECS# WT% (REG.SECTION)
Attachment NOC-AE-14003142 Page 118 of 155 UNIVAR USA INC.                                                                                     MSDS NO:OX76685 ISSUE DATE:201 1-12-21                                                                       VERSION:010 2014-03-18 Annotation:
RQ(LBS)Sodiun Hypochlorite 7681-52-9  
COMPANY IDENTITY:     Univar                                                         DATE: 12/21/11 PRODUCT IDENTITY:     OX76685                                                         PAGE: 8 OF 8 SECTION 15. REGULATORY INFORMATION EPA REGULATION:
-<,16 (311,312) lee Sodium Hydroxide 1310-73-2  
SARA SECTION 311/312 HAZARDS: Acute Health All components of this product are on the TSCA list, This material contains no known products restricted under SARA Title III, Section 313 in amounts greater or equal to 1%.
-. __.. ..> 625 LB / 284 KG OF THIS PRODUCT IN 1 CONTAINER EXCEEDS THE "RQ' OF SODIUM HYPOCHLORITE.
SARA TITLE III INGREDIENTS             CAS#     EINECS#   WT%     (REG.SECTION)       RQ(LBS)
Sodiun Hypochlorite           7681-52-9       -       <,16   (311,312)               lee Sodium Hydroxide               1310-73-2       -.           __..             ..
      > 625 LB / 284 KG OF THIS PRODUCT IN 1 CONTAINER EXCEEDS THE "RQ' OF SODIUM HYPOCHLORITE.
Any release equal to or exceeding the RQ must be reported to the National Response Center (800-424-8802) and appropriate state and local regulatory agencies as described in 40 CFR 302.6 and 40 CFR 355..40 respectively.
Any release equal to or exceeding the RQ must be reported to the National Response Center (800-424-8802) and appropriate state and local regulatory agencies as described in 40 CFR 302.6 and 40 CFR 355..40 respectively.
Failure to report may result in substantial civil and criminal penalties, State & local regulations may be more restrictive than federal regulations, STATE REGULATIONS:
Failure to report may result in substantial civil and criminal penalties, State & local regulations may be more restrictive than federal regulations, STATE REGULATIONS:
CALIFORNIA PROPOSITION 65: This product contains no chemicals known to the State of California to cause cancer & reproductive toxicity.U.S. STATE REGULATED COMPONENTS: (HAZARDOUS SUBSTANCE LISTS)::OMPONENT AK CA F.L IL KS MA HI MN Sodium Hypochlorlte No No No Yes No No No No Sodium Hydroxide Yes Yes Yes Yes Yes Yes Yes Yes:OMPONENT MO NJ ND PA RI TX WV WI Sodium Hypochlorite No Yes Yes No No No No No Sodium Hydroxide Yes Yes Yes Yes Yes Yes Yes Yes INTERNATIONAL REGULATIONS The components of this product are listed on the chemical inventories of the... .Qllowngcountries.:.,-...-  
CALIFORNIA PROPOSITION 65: This product contains no chemicals known to the State of California to cause cancer & reproductive toxicity.
...... ... ...........
U.S. STATE REGULATED COMPONENTS:     (HAZARDOUS SUBSTANCE LISTS):
Australia (AICS), Canada (DSL, NDSL), China (IECSC), Europe (EINECS, ELINCS)J Japan (METI/CSCL, MHLW/ISHL), South Korea (KECI), New Zealand (NZIoC), Philippines (PICCS), Switzerland (SWISS), Taiwan (NECSI), USA (TSCA).CANADA: WORKPLACE HAZARDOUS MATERIALS INFORMATION SYSTEM (WHMIS)*C: Oxidizing Material.D2B: Irritating to skin / eyes.E: Corrosive Material.SECTION 16. OTHER INFORMATION HAZARD RATINGS: HEALTH .(NFPA): 3, HEALTH (HMIS): 3, FLAMMABILITY:
:OMPONENT                         AK     CA       F.L IL     KS       MA     HI     MN Sodium Hypochlorlte               No     No       No   Yes     No       No     No     No Sodium Hydroxide                 Yes     Yes     Yes Yes     Yes     Yes     Yes     Yes
8, REACTIVITY:
:OMPONENT                         MO     NJ       ND   PA       RI     TX     WV     WI Sodium Hypochlorite               No     Yes     Yes No       No     No     No     No Sodium Hydroxide                 Yes   Yes     Yes Yes     Yes     Yes     Yes     Yes INTERNATIONAL REGULATIONS The components of this product are listed on the chemical inventories of the
1 (Personal Protection Rating to be supplied by user based on use conditions.)
  ...   .Qllowngcountries.:.,-...-                                     ......                                   ...     ...........
This information is intended solely for the use of individuals trained in the NFPA & HMIS hazard rating systems.EMPLOYEE TRAINING See Section 2 for Risk & Safety Statements.
Australia (AICS), Canada (DSL, NDSL), China (IECSC), Europe (EINECS, ELINCS)J Japan (METI/CSCL, MHLW/ISHL), South Korea (KECI), New Zealand (NZIoC),
Employees should be made aware of all hazards of this material (as stated in this SDS) before handling it.
Philippines (PICCS), Switzerland (SWISS), Taiwan (NECSI), USA (TSCA).
Attachment NOC-AE-14003142 Page 119 of 155 Univar USA Inc Material Safety Data Sheet For Additional Information contact. MSDS Coordinator during business hours, Pacific time: (425) 889-3400 Notice Univar USA Inc. ("Univar")
CANADA: WORKPLACE HAZARDOUS MATERIALS INFORMATION SYSTEM (WHMIS)
expressly disclaims all express or implied warranties of merchantability and fitness for a particular purpose, with respect to the product or information provided herein, and shall under no circumstances be liable for Incidental or consequential damages.Do not use ingredient information and/or ingredient percentages In this MSDS as a product specification.
          *C: Oxidizing Material.
For product specification Information refer to a product specification sheet and/or a certificate of analysis.
D2B: Irritating to skin / eyes.
These can be obtained from your local Univar sales office.All information appearing herein is based upon data obtained from the manufacturer and/or recognized technical sources. While the Information is believed to be accurate, Univar makes no representations as to its accuracy or sufficiency.
E:   Corrosive Material.
Conditions of use are beyond Univar's control and therefore users are responsible to verify this data under their own operating conditions to determine whether the product is suitable for their particular purposes and they assume all risks of their use, handling, and disposal of the product, or from the publication or use of, or reliance upon, Information contained herein.This information relates only to the product designated herein, and does not relate to its use in combination with any other material or in any other process Attachment NOC-AE-14003142 Page 120 of 155.P4LCO SAFETY DATA SHEET , -/b (PRODUCT NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER(S)(800) 424-9300(24 Hours) CHEMTREC I 1. I CHEMICAL PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME: APPLICATION
SECTION 16. OTHER INFORMATION HAZARD RATINGS:
: NALCO 1359 PLUS CORROSION INHIBITOR COMPANY IDENTIFICATION:
HEALTH .(NFPA): 3,     HEALTH (HMIS): 3,       FLAMMABILITY: 8,       REACTIVITY: 1 (Personal Protection Rating to be supplied by user based on use conditions.)
Nalco Company 1601 W. Diehl Road Naoerville.
This information is intended solely for the use of individuals trained in the NFPA & HMIS hazard rating systems.
Illinois 60563-1198 EMERGENCY TELEPHONE NUMBER(S):
EMPLOYEE TRAINING See Section 2 for Risk & Safety Statements. Employees should be made aware of all hazards of this material (as stated in this SDS) before handling it.
(800) 424-9300 (24 Hours) CHEMTREC NFPA 704MIHMIS RATING HEALTH: 313 FLAMMABILITY:
 
0/0 INSTABILITY:
Attachment NOC-AE-14003142 Page 119 of 155 Univar USA Inc Material Safety Data Sheet For Additional Information contact. MSDS Coordinator during business hours, Pacific time: (425) 889-3400 Notice Univar USA Inc. ("Univar") expressly disclaims all express or implied warranties of merchantability and fitness for a particular purpose, with respect to the product or information provided herein, and shall under no circumstances be liable for Incidental or consequential damages.
010 OTHER: 0 = Insignificant 1 =Slight. 2 =Moderate 3 =High 4 =Extreme * =Chronic Health Hazard I 2. .I COMPOSITIONIINFORMATION ON INGREDIENTS I I Our hazard evaluation has Identified the following chemical substance(s) as hazardous.
Do not use ingredient information and/or ingredient percentages In this MSDS as a product specification. For product specification Information refer to a product specification sheet and/or a certificate of analysis. These can be obtained from your local Univar sales office.
Consult Section 15 for the nature of the hazard(s).
All information appearing herein is based upon data obtained from the manufacturer and/or recognized technical sources. While the Information is believed to be accurate, Univar makes no representations as to its accuracy or sufficiency. Conditions of use are beyond Univar's control and therefore users are responsible to verify this data under their own operating conditions to determine whether the product is suitable for their particular purposes and they assume all risks of their use, handling, and disposal of the product, or from the publication or use of, or reliance upon, Information contained herein.
Hazardous Substance(s)
This information relates only to the product designated herein, and does not relate to its use in combination with any other material or in any other process
Sodium Nitrite Sodium Metaborate CAS NO 7632-00-0 7775-19-1% (w/w)10.0- 30.0 5.0- 10.0 13..HA.ADS...N I C.T......  
 
.. --.~EMERGENCY OVERVIEW" DANGER Toxic if swallowed.
Attachment NOC-AE-14003142 Page 120 of 155 SAFETY DATA SHEET                           ,   -/b     (
Irritating to eyes and skin. Contains sodium nitrite. Substances In the product can lead to the formation of methemoglobin.
    .P4LCO                                              PRODUCT NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER(S)
Unborn children are particularly sensitive to methemoglobinemia.
(800) 424-9300(24 Hours) CHEMTREC I 1.         I CHEMICAL PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME:                                       NALCO 1359 PLUS APPLICATION :                                        CORROSION INHIBITOR COMPANY IDENTIFICATION:                             Nalco Company 1601 W. Diehl Road Naoerville. Illinois 60563-1198 EMERGENCY TELEPHONE NUMBER(S):                       (800) 424-9300 (24 Hours)     CHEMTREC NFPA 704MIHMIS RATING HEALTH:         313       FLAMMABILITY:         0/0     INSTABILITY:       010     OTHER:
Do not get in eyes, on skin, on clothing.
0 = Insignificant 1 =Slight. 2 =Moderate 3 =High 4 =Extreme               * =Chronic Health Hazard I 2.       .I COMPOSITIONIINFORMATION ON INGREDIENTS                                                                       II Our hazard evaluation has Identified the following chemical substance(s) as hazardous. Consult Section 15 for the nature of the hazard(s).
Do not take internally.
Hazardous Substance(s)                                    CAS NO                      %(w/w)
Use with adequate ventilation.
Sodium Nitrite                                                                 7632-00-0                 10.0- 30.0 Sodium Metaborate                                                              7775-19-1                  5.0- 10.0 13..HA.ADS...N                     I C.T......                                         ..                 --.
In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. After contact with skin, wash Immediately with plenty of water.Wear suitable protective clothing.Not flammable or combustible.
                                                ~EMERGENCY OVERVIEW" DANGER Toxic if swallowed. Irritating to eyes and skin. Contains sodium nitrite. Substances In the product can lead to the formation of methemoglobin. Unborn children are particularly sensitive to methemoglobinemia.
May evolve oxides of nitrogen (NOx) under fire conditions.
Do not get in eyes, on skin, on clothing. Do not take internally. Use with adequate ventilation. In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. After contact with skin, wash Immediately with plenty of water.
If product is allowed to dry, the sodium nitrite is an oxidizing agent and can Initiate the combustion of other materials.
Wear suitable protective clothing.
PRIMARY ROUTES OF EXPOSURE: Eye, Skin HUMAN HEALTH HAZARDS -ACUTE: EYE CONTACT: .Irritating, and may injure eye tissue if not removed promptly.Nalco Company 1601 W. Diehl Road -Naperville, Illinois 60563-1198  
Not flammable or combustible. May evolve oxides of nitrogen (NOx) under fire conditions. Ifproduct is allowed to dry, the sodium nitrite is an oxidizing agent and can Initiate the combustion of other materials.
-(630)305-1000 For additional copies of an MSDS visit wwv.nalco.com and request access.1110 I Attachment NOC-AE-14003142 Page 121 of 155 SNALCO SKiN CONTACT::Can cause mild Irritation.
PRIMARY ROUTES OF EXPOSURE:
SAFETY DATA SHEET NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER(S)(800) 424-9300(24 Hours) CHENTREC INGESTION:
Eye, Skin HUMAN HEALTH HAZARDS - ACUTE:
Not a likely route of exposure.
EYE CONTACT: .
Large exposures may be fatal. Ingestion of sodium nitrite can cause methemoglobinemia which can lead to cyanosis and possible death. Pregnant women and their fetuses are particularly sensitive to the effects of methemoglobinemia.
Irritating, and may injure eye tissue if not removed promptly.
IN HALATIO N : --_-U -_ ___ ___ ____ ___ ___ __r Not alikely route otexposure.
Nalco Company 1601 W. Diehl Road -Naperville, Illinois 60563-1198 - (630)305-1000 For additional copies of an MSDS visit wwv.nalco.com and request access.
Aeri6tsoTs r t-6ra6cf til nTa-fle t"pe pT ct.SYMPTOMS OF EXPOSURE: Acute : A review of available data does not identify any symptoms from exposure not previously mentioned.
1110 I
 
Attachment NOC-AE-14003142 Page 121 of 155 SAFETY DATA SHEET SNALCO NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300(24 Hours) CHENTREC SKiN CONTACT:
:Can cause mild Irritation.
INGESTION:
Not a likely route of exposure. Large exposures may be fatal. Ingestion of sodium nitrite can cause methemoglobinemia which can lead to cyanosis and possible death. Pregnant women and their fetuses are particularly sensitive to the effects of methemoglobinemia.
IN HALATIO N :                             --       -_                                                  _-U           ___   ___   ____     ___   ___   __r Not alikely route otexposure. Aeri6tsoTs r                   til           nTa-fle t"pe           pT         t-6ra6cf ct.
SYMPTOMS OF EXPOSURE:
Acute :
A review of available data does not identify any symptoms from exposure not previously mentioned.
Chronic A review of available data does not identify any symptoms from exposure not previously mentioned, AGGRAVATION OF EXISTING CONDITIONS:
Chronic A review of available data does not identify any symptoms from exposure not previously mentioned, AGGRAVATION OF EXISTING CONDITIONS:
Sodium Nitrite. Pregnant women are particularly sensitive to methemoglobinemia.
Sodium Nitrite. Pregnant women are particularly sensitive to methemoglobinemia.
HUMAN HEALTH HAZARDS -CHRONIC: Repeated ingestion of small amounts of sodium nitritecauses drops In blood pressure, rapid pulse, headaches and visual disturbances.
HUMAN HEALTH HAZARDS - CHRONIC:
It may also reactwith organic amines in the body to form carcinogenic nitrosamines.
Repeated ingestion of small amounts of sodium nitritecauses drops In blood pressure, rapid pulse, headaches and visual disturbances. Itmay also reactwith organic amines in the body to form carcinogenic nitrosamines.
: 14. 1FIRST AID MEASURES EYE CONTACT: Immediately flush eye with water for at least 15 minutes while ho!ding eyelids open. If irritation persists, repeat.. ... .. ....fl ush ln gT-G thid t la thdoi. .. .... ......a ..............
: 14.         1FIRST AID MEASURES EYE CONTACT:
...... ... .. .. ............................  
.. . .... .. . .flImmediately    t eye flush ush ln gT-G thid   alawith thdoi.             . . ..15......
.. .. .... .:... ... '.. .. ..SKINCONTACT:
water for at.. least    minutes    while ho!ding
Immediately flush with plenty of water for at least 15 minutes. If symptoms persist, call a physician, INGESTION:
                                                                                ..............         ... .. ..open.
Do not induce vomiting without medical advice. If conscious, washout noutlh and give water to drink. Get Immediate medical attention.
                                                                                              ...... eyelids          Ifirritation persists, repeat SKINCONTACT:
Immediately flush with plenty of water for at least 15 minutes. Ifsymptoms persist, call a physician, INGESTION:
Do not induce vomiting without medical advice. Ifconscious, washout noutlh and give water to drink. Get Immediate medical attention.
INHALATION:
INHALATION:
Remove to fresh air, treat symptomatically.
Remove to fresh air, treat symptomatically. If symptoms develop, seek medical advice.
If symptoms develop, seek medical advice.NOTE TO PHYSICIAN:
NOTE TO PHYSICIAN:
Based an the individual reactions of the patient, the physician's judgement should be used to control symptoms and clinical condition.
Based an the individual reactions of the patient, the physician's judgement should be used to control symptoms and clinical condition. Measures against circulatory shock, respiratory depression and convulsions may be needed.
Measures against circulatory shock, respiratory depression and convulsions may be needed.Nalco Company 1601 W. Diehl Road -Naperville, Illinois 60563-1198-(630)305.1000 For additional copies of an MSDS visit www.nalco.com and request access.2110 Attachment NOC-AE-14003142 Page 122 of 155-&#xfd;tNImA LCO `SAFETY DATA SHEET PRODUCT NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER(S)1800) 424-9300 (24 Hours) CHEMTREC I S. I FIRE FIGHTING MEASURES I 15. 1 FIRE FIGHTING MEASURES I FLASH POINT: None EXTINGUISHING MEDIA: Not expected to bum. Use extinguishing media appropriate for surrounding fire.FIRE AND EXPLOSION HAZARD:.Not flammable or combustibNI7 May evolve oxides.of nitrogen (NOx) under tire conditions.
Nalco Company 1601 W. Diehl Road - Naperville, Illinois 60563-1198- (630)305.1000 For additional copies of an MSDS visit www.nalco.com and request access.
If product is allowed to dry, the sodium nitrite Is an.oxidizing agent and can initiate the combustion of other materials.
2110
SPECIAL PROTECTIVE EQUIPMENT FOR FIRE FIGHTING: In case of fire, wear a full face positive-pressure.self contained breathing apparatus and protective suit.16. 1 ACCIDENTAL RELEASE MEASURES PERSONAL PRECAUTIONS:
 
Restrict access to area as appropriate until clean-up operationsi are complete.
Attachment NOC-AE-14003142 Page 122 of 155 SAFETY DATA SHEET PRODUCT
Ensure clean-up it conducted by trained personnel only. Ventilate spill area if possible.
        - &#xfd;tNImA LCO `                                       NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER(S) 1800) 424-9300 (24 Hours) CHEMTREC I S.       I FIRE FIGHTING MEASURES                                                                                       II
Do not touch spilled material.
: 15.       1 FIRE FIGHTING MEASURES FLASH POINT:                                   None EXTINGUISHING MEDIA:
Stop or reduce anyleaks if It is safe to do so. Use personal protective equipment recommended In Section 8 (Exposure Controls/Personal Protection).
Not expected to bum. Use extinguishing media appropriate for surrounding fire.
Notify appropriate government, occupational health and safetyand environmental authorities.
FIRE AND EXPLOSION HAZARD:.
METHODS FOR CLEANING UP: SMALL SPILLS:. Soakup spill with absorbent material, Place residues in a suitable, covered, properly labeled container.
Not flammable or combustibNI7 May evolve oxides.of nitrogen (NOx) under tire conditions. Ifproduct is allowed to dry, the sodium nitrite Is an.oxidizing agent and can initiate the combustion of other materials.
Wash affected area. LARGE SPILLS: Contain liquid using absorbent material, by digging trenches or by diking. Reclaim Into recovery or salvage drums or tank truck for proper disposal.
SPECIAL PROTECTIVE EQUIPMENT FOR FIRE FIGHTING:
Wash site of spillage thoroughly with water. Contact an approved waste hauler for disposal of contaminated recovered material.
In case of fire, wear a full face positive-pressure.self contained breathing apparatus and protective suit.
Dispose of material in..... ... ....................
: 16.       1 ACCIDENTAL RELEASE MEASURES PERSONAL PRECAUTIONS:
6MP It66WMiiia hii i -ed di-S i6- 13-(D -e tikoi .............
Restrict access to area as appropriate until clean-up operationsi are complete. Ensure clean-up it conducted by trained personnel only. Ventilate spill area if possible. Do not touch spilled material. Stop or reduce anyleaks if Itis safe to do so. Use personal protective equipment recommended In Section 8 (Exposure Controls/Personal Protection). Notify appropriate government, occupational health and safetyand environmental authorities.
METHODS FOR CLEANING UP:
SMALL SPILLS:. Soakup spill with absorbent material, Place residues in a suitable, covered, properly labeled container. Wash affected area. LARGE SPILLS: Contain liquid using absorbent material, by digging trenches or by diking. Reclaim Into recovery or salvage drums or tank truck for proper disposal. Wash site of spillage thoroughly with water. Contact an approved waste hauler for disposal of contaminated recovered material. Dispose of material in
..... .6MP It66WMiiia hii                     i d* ffi*
                                                -eddi-S i6- 13-(D         1*Zsa
                                                                            - *d e tikoi   .............
ENVIRONMENTAL PRECAUTIONS:
ENVIRONMENTAL PRECAUTIONS:
Do not contaminate surface.water.
Do not contaminate surface.water.
7i HANDLING ANDSTORAGE HANDLING: Do not get in eyes, on sklnj on clothing.
7i           HANDLING ANDSTORAGE HANDLING:
Do not take internally.
Do not get in eyes, on sklnj on clothing. Do not take internally. Use with adequate ventilation. Do not breathe vapors/gases/dust. Keep the containers closed when not In use. Have emergency equipment (for fires, spills, leaks, etc.) readily available. Ensure all containers are labeled.
Use with adequate ventilation.
STORAGE CONDITIONS:
Do not breathe vapors/gases/dust.
Store the containers tghUy closed. Store insuitable labeled containers, Store separately from acids. Store separately from reducing agents.
Keep the containers closed when not In use. Have emergency equipment (for fires, spills, leaks, etc.) readily available.
1 8.       1 EXPOSURE CONTROLS/PERSONAL PROTECTION OCCUPATIONAL EXPOSURE LIMITS:
Ensure all containers are labeled.STORAGE CONDITIONS:
This product does not contain any substance that has an established exposure limit.
Store the containers tghUy closed. Store in suitable labeled containers, Store separately from acids. Store separately from reducing agents.1 8. 1 EXPOSURE CONTROLS/PERSONAL PROTECTION OCCUPATIONAL EXPOSURE LIMITS: This product does not contain any substance that has an established exposure limit.Nalco Company 1601 W. Diehl Road 'Naperville, Illinois 60563-1198, (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.3110 Attachment NOC-AE-14003142 Page 123 of 155 NANALCO SAFETY DATA SHEET PRODUCT NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER(S)(B00) 424-$300 (24 Hours) CHEMTREC ENGINEERING MEASURES: General ventilation is recommended.
Nalco Company 1601 W. Diehl Road 'Naperville, Illinois 60563-1198, (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.
3110
 
Attachment NOC-AE-14003142 Page 123 of 155 SAFETY DATA SHEET PRODUCT NANALCO                                  NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER(S)
(B00) 424-$300 (24 Hours) CHEMTREC ENGINEERING MEASURES:
General ventilation is recommended.
RESPIRATORY PROTECTION:
RESPIRATORY PROTECTION:
Respiratory protection is not normally needed.HAND PROTECTION:
Respiratory protection is not normally needed.
......
HAND PROTECTION:
work conditions and what chemicals are handled, but we have positive experience under light handling conditions using gloves made from Neoprene PVC or nitrite Gloves should be replaced immediately If signs of degradation are observed.  
...... __WbembandliLngthispruo.dctthe-useDLchemicalgaunhLetss-rcommaended.L*beachcice-oLwork-glove-depends.on work conditions and what chemicals are handled, but we have positive experience under light handling conditions using gloves made from Neoprene PVC or nitrite Gloves should be replaced immediately If signs of degradation are observed. 'Breakthrough time not determined as preparation, consult PPE manufacturers.
'Breakthrough time not determined as preparation, consult PPE manufacturers.
SKIN PROTECTION:
SKIN PROTECTION:
When handling this product, the use of overalls, a chemical resistant apron and rubber boots is recommended.
When handling this product, the use of overalls, a chemical resistant apron and rubber boots is recommended. A full slicker suit Is recommendedif gross exposure is possible.
A full slicker suit Is recommendedif gross exposure is possible.EYE PROTECTION:
EYE PROTECTION:
Wear chemical splash goggles.HYGIENE RECOMMENDATIONS:
Wear chemical splash goggles.
Use good work and personal hygiene practices to avoid exposure.
HYGIENE RECOMMENDATIONS:
Keep an eye wash fountain available.
Use good work and personal hygiene practices to avoid exposure. Keep an eye wash fountain available. Keep a safety shower available, If clothing is contaminated, remove clothing and thoroughly wash the affected area. Launder contaminated clothing before reuse, Always wash thoroughly after handling chemicals, When handling this product never eat, drink or smoke.
Keep a safety shower available, If clothing is contaminated, remove clothing and thoroughly wash the affected area. Launder contaminated clothing before reuse, Always wash thoroughly after handling chemicals, When handling this product never eat, drink or smoke.HUMAN EXPOSURE CHARACTERIZATION:
HUMAN EXPOSURE CHARACTERIZATION:
Based on our recommended product application and personal protective eq.uipment the potentialhuman exposure Is:.S...Mod edrte --.. .'........
Based on our recommended product application and personal protective eq.uipment the potentialhuman exposure Is:.
: 19. 1 PHYSICAL AND CHEMICAL PROPERTIES.PHYSICAL STATE APPEARANCE Liquid Light yellow ODOR SPECIFIC GRAVITY DENSITY SOLUBILITY IN WATER pH (100 %)VISCOSITY FREEZING POINT VAPOR PRESSURE 1.305 @ 72 -F 122.2 -C 10.84 lb/gal Complete>= 11.4 Max 7 cps @ 73 &deg;F 122.8 *C<.-50 OF 1-45.5 QC Same as water Note: These physical properties are typical values for this product and are subject to change.Nalco Company 1601 W. Diehl Road
S...Mod edrte         - - ..                                                                 .'........
* Napervltle, Illinois 60563-1198  
: 19.         1PHYSICAL AND CHEMICAL PROPERTIES
* (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.4/10 Attachment NOC-AE-14003142 Page 124 of 155 N NALC0 10. STABILITY AND REACTIVITY STABILITY:
          .PHYSICAL STATE               Liquid APPEARANCE                   Light yellow ODOR SPECIFIC GRAVITY                         1.305 @ 72 -F 122.2 -C DENSITY                                  10.84 lb/gal SOLUBILITY IN WATER                      Complete pH (100 %)                                >= 11.4 VISCOSITY                                Max 7 cps @ 73 &deg;F 122.8 *C FREEZING POINT                            <.-50 OF 1-45.5 QC VAPOR PRESSURE                            Same as water Note: These physical properties are typical values for this product and are subject to change.
Nalco Company 1601 W. Diehl Road
* Napervltle, Illinois 60563-1198 * (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.
4/10
 
Attachment NOC-AE-14003142 Page 124 of 155 SAFETY DATA SHEET NALC0 N                                         PRODUCT NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER(S)
(800) 424.9300(24 Hours) CHEMTREC
: 10.       STABILITY AND REACTIVITY STABILITY:
Stable under normal conditions.
Stable under normal conditions.
HAZARDOUS POLYMERIZATION; Hazardous polymerization will not occur.SAFETY DATA SHEET PRODUCT NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER(S)(800) 424.9300(24 Hours) CHEMTREC*CONDIrONSWTO-AvOlD.
HAZARDOUS POLYMERIZATION; Hazardous polymerization will not occur.
Freezing temperattres.
*CONDIrONSWTO-AvOlD.
Do not allow product to evaporate to dryness. Dried product residue can act as an oxidizer.MATERIALS TO AVOID: Contact with reducing agents (e.g. hydrazine, sulfites, sulfide, aluminum or magnesium dust) may generate heat, fires, explosions and tOXic vapors. Do not mix with amines, Sodium nitrite can react with certain amines to produce N-nitrosamines, Many of which are cancer-causing agents to laboratory animals. Contact with strong acids (e.g.sulfuric, phosphoric, nitric, hydrochloric, chromic, sulfonlc) may generate heat, splattering or boiling and toxic vapors.HAZARDOUS DE(OOMPOSITION PRODUCTS :.Under fire conditiolis:
Freezing temperattres. Do not allow product to evaporate to dryness. Dried product residue can act as an oxidizer.
Oxides of nitrogen 11. 1 ToXI-_LOGICAL INFORMATION No toxicity studies have been conducted on this product.SENSITIZATION  
MATERIALS TO AVOID:
: This product Is not expected to be a sensitizer.
Contact with reducing agents (e.g. hydrazine, sulfites, sulfide, aluminum or magnesium dust) may generate heat, fires, explosions and tOXic vapors. Do not mix with amines, Sodium nitrite can react with certain amines to produce N-nitrosamines, Many of which are cancer-causing agents to laboratory animals. Contact with strong acids (e.g.
None of the substances In this product are listed as carcinogens by the International Agency for Research on Cancer (IARC), the Nationcl Toxicology Program (NTP) or the American Conference of Governmental Industrial.
sulfuric, phosphoric, nitric, hydrochloric, chromic, sulfonlc) may generate heat, splattering or boiling and toxic vapors.
Hygienists (ACGIH)..HUMAN HAZARD CHARACTERIZATION:
HAZARDOUS DE(OOMPOSITION PRODUCTS :.
Based on bur hazard characterization, the potential human hazard is: High 12. 1 ECOL-GICAL INFORMATION ECOTOXICOLOGICAL EFFECTS: No toxicity studies have been-conducted on this product.MOBILITY: The environmental fate was estimated using a level III fugacity model embedded in the EPI (estimation program ineace) Suite TM, provided by the US EPA. The Model assumes a steady state condition between the total input and output. The level III model does not require equilibrium between the .defined media. The informtation provided is intended to give th user a general estimate of the environmental fate of this productunder the defined conditions of the models, NA0o Co'mpany 1601 W. Diehl Road Naperville, Illinois 60563.1198  
Under fire conditiolis:             Oxides of nitrogen
' (630)305-1000 For additional copies of an MSDS visit wvw.nalco.com and request access.5110 Attachment NOC-AE-14003142 Page 125 of 155) 4 NOA LL'0 SAFETY DATA SHEET PRODUCT NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER(S)(800) 424-9300 (24 Hours) CHEMTREC If released Into the environment this material Is expected to distribute to the.air, water and scil/sediment in the approximate respective percentages; Air WtrSoil/Sediment
: 11.     1ToXI-_LOGICAL INFORMATION No toxicity studies have been conducted on this product.
<5% 30-50% 50-70%The portion in water is expected to be soluble or dispersible.
SENSITIZATION :
ENVIRONMENTA.-TAZ'AR DAN 1EXPO SURE-CH AP,-TER IZAT-10 Based on our hazard characterization, the potential environmental hazard is: Moderate Based on our recommended product application and the product's characteristics, the potential environmental exposure Is: High If released Into the environment, see CERCLA/SUPERFUND in Section 15.I 13. I DISPOSAL CONSIDERATIONS I If this product becomes a waste, it could meet the criteria of a hazardous waste as defined by the Resource Conservation and Recovery Act (RCRA) 40 CFR 261, Before disposal, It should be determined If the waste meets the criteria of a hazardous waste, Hazardous Waste: D002 Hazardous wastes must be transported by e licensed hazardous waste transporter and disposed of or treated in a properly licensed hazardous waste treatment, storage, disposal or recycling facility.
This product Is not expected to be a sensitizer.
Consult local, state, and federal regulations for specific requirements.
None of the substances In this product are listed as carcinogens by the International Agency for Research on Cancer (IARC), the Nationcl Toxicology Program (NTP) or the American Conference of Governmental Industrial. Hygienists (ACGIH)..
i RTRANSPORTINFORMATION  
HUMAN HAZARD CHARACTERIZATION:
.- .."----.-The Information In this section is for reference only and should not take the place of a shipping paper (bill of lading)specific to an order. Please note that the proper Shipping Name I Hazard Class may vary by packaging, properties, and mode of transportation.
Based on bur hazard characterization, the potential human hazard is: High
Typical Proper Shipping Names oe this product are as follows.LAND TRANSPORT:
: 12.     1ECOL-GICAL INFORMATION ECOTOXICOLOGICAL EFFECTS:
Proper Shipping Name: Technical Name(s): UN/ID No: Hazard Class -Primary: Hazard Class -Secondary:
No toxicity studies have been-conducted on this product.
Packing Group: Flash Point: Reportable Quantity (per package): RQ Component:
MOBILITY:
AIR TRANSPORT (ICAOIIATA):
The environmental fate was estimated using a level III fugacity model embedded in the EPI (estimation program ineace) Suite TM, provided by the US EPA. The Model assumes a steady state condition between the total input and output. The level III model does not require equilibrium between the.defined media. The informtation provided is intended to give th user a general estimate of the environmental fate of this productunder the defined conditions of the models, NA0o Co'mpany 1601 W. Diehl Road Naperville, Illinois 60563.1198 ' (630)305-1000 For additional copies of an MSDS visit wvw.nalco.com and request access.
Proper Shipping Name: CORROSIVE LIQUID, TOXIC, N.O.S SODIUM NITRITE UN 2922 8 6.1 III None 430 lbs SODIUM NITRITE CORROSIVE LIQUID. TOXIC, NO.S Nalco Company 1601 W. Diehl Road -Naperville, Illinois 60563-1198  
5110
(-630)305-1000 For additional copies of an MSDS visit www, nalco.com and request access.6110 Attachment NOC-AE-14003142 Page 126 of 155~N A LUC= 0 SAFETY DATA SHEET PRODUCT NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER(S)(800) 424-9300(24 Hours) CHEMTREC Technical Name(s): UNIID No: Hazard Class -Primary: Hazard Class -. Secondary:
 
Packing Group: Reportable Quantity (per package): RQ Component:
Attachment NOC-AE-14003142 Page 125 of 155 SAFETY DATA SHEET
MARINE TRANSPORT (IMDG/IMO):
    )4NOA LL'0                                         PRODUCT NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER(S)
SODIUM NITRITE UN 2922 8 6.1 III 430 lbs SODIUM NITRITE P-operShipping-Name  
(800) 424-9300 (24 Hours) CHEMTREC If released Into the environment this material Is expected to distribute to the.air, water and scil/sediment in the approximate respective percentages; Air                     WtrSoil/Sediment
: Technical Name(s): UNIID No: Hazard Class -Primary: Hazard Class -Secondary:
                    <5%                     30-50%                   50-70%
Packing Group:-CORROSIVE-LIQUID;-TOXIG,-.G-.S SODIUM NITRITE UN 2922 8 6.1 III I 15. I REGULATORY INFORMATION I This section contains additional Information that may have relevance to regulatory compliance.
The portion in water is expected to be soluble or dispersible.
The information in this section is for reference only. It Is not exhaustive, and should no' be relied Upon to take the place of an individualized compliance or hazard assessment.
ENVIRONMENTA.-TAZ'AR DAN 1EXPO SURE-CH AP,-TER IZAT-10 Based on our hazard characterization, the potential environmental hazard is: Moderate Based on our recommended product application and the product's characteristics, the potential environmental exposure Is: High Ifreleased Into the environment, see CERCLA/SUPERFUND in Section 15.
Nalco accepts no liability for the use of this information.
I 13.       I DISPOSAL CONSIDERATIONS                                                                                       I If this product becomes a waste, it could meet the criteria of a hazardous waste as defined by the Resource Conservation and Recovery Act (RCRA) 40 CFR 261, Before disposal, Itshould be determined If the waste meets the criteria of a hazardous waste, Hazardous Waste: D002 Hazardous wastes must be transported by e licensed hazardous waste transporter and disposed of or treated in a properly licensed hazardous waste treatment, storage, disposal or recycling facility. Consult local, state, and federal regulations for specific requirements.
NATIONAL REGULATIONS, USA: OSHA HAZARD COMMUNICATION RULE, .29 CFR 1910.1200:
i             RTRANSPORTINFORMATION                 .-                                       .."----.-
Based on our hazard evaluation, the following substance(s) in this product is/are hazardous and the reason(s) islare shown below.So.Ndium.Nt.te  
The Information In this section is for reference only and should not take the place of a shipping paper (bill of lading) specific to an order. Please note that the proper Shipping Name I Hazard Class may vary by packaging, properties, and mode of transportation. Typical Proper Shipping Names oethis product are as follows.
..:-TargtO.Qrga-Enffe L-;.I.doey,Target-Organ:Effect ,Nervous~systemTarget:Organ.Effect:.,:-loodI.;
LAND TRANSPORT:
Sodium Metaborate.:
Proper Shipping Name:                         CORROSIVE LIQUID, TOXIC, N.O.S Technical Name(s):                             SODIUM NITRITE UN/ID No:                                     UN 2922 Hazard Class - Primary:                       8 Hazard Class - Secondary:                     6.1 Packing Group:                                 III Flash Point:                                   None Reportable Quantity (per package):             430 lbs RQ Component:                                 SODIUM NITRITE AIR TRANSPORT (ICAOIIATA):
Irritant CERCLA!SUPERFUNDO 40 CFR 302: This product contains the following Reportable Quantity (RO) Substance.
Proper Shipping Name:                         CORROSIVE LIQUID. TOXIC, NO.S Nalco Company 1601 W. Diehl Road - Naperville, Illinois 60563-1198 (-630)305-1000 For additional copies of an MSDS visit www,nalco.com and request access.
Also listed is the RO for the product.*RO.Substance Sodium Nitrte B2q 430 Ibis SARANSUPERFUND AMENDMENTS AND REAUTHORIZATION ACT OF 1986 (TITLE III) -SECTIONS 302, 311, 312t AND 313: SECTION 302 -EXTREMELY HAZARDOUS SUBSTANCES (40 CFR 355): This product does not contain substances listed in Appendix A and B as an Extremely Hazardous Substance.
6110
SECTIONS 311 AND 312 -MATERIAL SAFETY DATA SHEET REQUIREMENTS (40 CFR 370): Our hazard evaluation has found this product to be hazardous.
 
The product should be reported under the following indicated EPA hazard categories:
Attachment NOC-AE-14003142 Page 126 of 155 SAFETY DATA SHEET
X Immediate. (Acute) Health HaZard Nalco Company 1601 W. Diehl Road
        ~N       A LUC= 0                               PRODUCT NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER(S)
* Naperville, Illinois 60563-1198  
(800) 424-9300(24 Hours) CHEMTREC Technical Name(s):                               SODIUM NITRITE UNIID No:                                       UN 2922 Hazard Class - Primary:                         8 Hazard Class -. Secondary:                       6.1 Packing Group:                                   III Reportable Quantity (per package):               430 lbs RQ Component:                                   SODIUM NITRITE MARINE TRANSPORT (IMDG/IMO):
-(630)305-1000 For additional copies of an MSDS visil vvw.nalco.com and request access.7110 Attachment NOC-AE-14003142 Page 127 of 155&#xfd;q N'AALC(eO%
P-operShipping-Name :                           -CORROSIVE-LIQUID;-TOXIG,-.G-.S Technical Name(s):                                SODIUM NITRITE UNIID No:                                        UN 2922 Hazard Class - Primary:                          8 Hazard Class - Secondary:                        6.1 Packing Group:                                    III I 15. I REGULATORY INFORMATION                                                                                         I This section contains additional Information that may have relevance to regulatory compliance. The information in this section is for reference only. It Is not exhaustive, and should no' be relied Upon to take the place of an individualized compliance or hazard assessment. Nalco accepts no liability for the use of this information.
SAFETY DATA SHEET PIRODUCT 7'NALCO 1359 PLUS EMERGENCY TELEPHONE NUMSER(S)(800) 424-9300 (24 Hours) CHEMTREC X Delayed (Chronic)
NATIONAL REGULATIONS, USA:
Health Hazard Fire Hazard Sudden Release of Pressure Hazard Reactive Hazard Under SARA 311 and 312, the EPA has established threshold quantities for the reporting of hazardous chemicals, The current thresholds are: 500 pounds or the threshold planning quantity (TPQ), whichever is lower, for extremely hazardous substances and 10,000 pounds for all other hazardous chemicals.
OSHA HAZARD COMMUNICATION RULE, .29 CFR 1910.1200:
_-SECLQFj_3J2,_._.L'O.FTQXJC..
Based on our hazard evaluation, the following substance(s) in this product is/are hazardous and the reason(s) islare shown below.
HEM.CALS_..CER,371)  
So.Ndium.Nt.te ..:-TargtO.Qrga-Enffe L-;.I.doey,Target-Organ:Effect ,Nervous~systemTarget:Organ.Effect:.,:-loodI.;
" This product contains the following substance(s), (with CAS # and % range) which appear(s) on the List of Toxic Chemicals Hazardous Substance(s)
Sodium Metaborate.: Irritant CERCLA!SUPERFUNDO 40 CFR 302:
CAS NO Sodium Nitrite 7632-00-0 10.0- 30.0 TOXIC SUBSTANCES CONTROL ACT (TSCA): The substances in this preparation are Included on or exempted from. the TSCA 8(b) Inventory (40 CFR 710)FEDERAL WATER POLLUTION CONTROL ACT, CLEAN WATER ACT, 40 CFR 401A 5 /formerly Sec, 307,40 CFR 116.4 Iformerly Sec. 311: This product contains the following substances listed in the regulation.
This product contains the following Reportable Quantity (RO) Substance. Also listed is the RO for the product.
Additional components may be unintentionally present at trace levels.Substance(s) s Citations" Sodium Nitrite Sec. 311" Sodium Hydroxide 11 Ozone Depleting Substances)  
          *RO.Substance Sodium Nitrte                                                 B2q 430 Ibis SARANSUPERFUND AMENDMENTS AND REAUTHORIZATION ACT OF 1986 (TITLE III) - SECTIONS 302, 311, 312t AND 313:
: Substances listed under this regulation are not Intentionally added or expected to be present In this product. Listed components may be present at trace levels.CALIFORNIA PROPOSITION 65: Substances listedunder California Proposition 65 are not Intentionally added or expected to be present In this product.MICHIGAN CRITICAL MATERIALS:
SECTION 302 - EXTREMELY HAZARDOUS SUBSTANCES (40 CFR 355):
Substances listed under this regulation are not intentionally added or expected to be present in this product. Listed components may be present at trace levels.STATE RIGHT TO KNOW LAWS The following substances are disclosed for compliance with State Right to Know Laws: Sodium Nitrite 7632-00-0 Nalco Company 1601 W. Diehl Road -Naperville, Illinois 60563-1198  
This product does not contain substances listed in Appendix A and B as an Extremely Hazardous Substance.
-(630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.8110 Attachment NOC-AE-14003142 Page 128 of 155 SNALCO SAFETY DATA SHEET.PRODUCT NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER(S)(800) 424-9;300 (24 Hours) CHEMTREC Threshold Limit Values for Chemical Substances and Physical Agents and Biological Exposure Indices, American Conference of Governmental Industrial Hygienists, OH., (Arlel InsightTU CD-ROM Version), Arnel Research Corp., Bethesda, MD.Hazardous Substances Data Bank, National Library of Medicine, Bethesda, Maryland (TOMES CPS"" CD-ROM Version), Micromedex, Inc., Englewood, CO.IARC Monographs on the Evaluation of [he Carcinogenic Risk of Chemicals to Man, Geneva: World Health Organl tio-rlilet to--A- e-c Integrated Risk Information System, U.S. Environmental Protection Agency, Washington, D.C. (TOMES CPSTm CD-ROM Version), Micromedex, Inc., Englewood, CO.Annual Report on Carcinogens, National Toxicology Program, U.S. Department of Health and HumanServices, Public Health Service.Title 29 Code of Federal Regulations, Part 1910, Subpart Z, Toxic and Hazardous Substances.
SECTIONS 311 AND 312 - MATERIAL SAFETY DATA SHEET REQUIREMENTS (40 CFR 370):
Occupational Safety and Health Administration (OSHA), (Arlel Insightm CD-ROM Version), Ariel Research Corp., Bethesda, MD.Registry of Toxic Effects of Chemical Substances, National Institute for Occupational Safety and Health, Cincinnati, OH, (TOMES CPS T M CD-ROM Version), Micromedex, Inc., Englewood, CO.Ariel InsightTu (An integrated guide to industrial chemicals covered under major regulatory and advisory programs), North American Module, Western European Module, Chemical Inventories Module and the Generics Module (Ariel.........
Our hazard evaluation has found this product to be hazardous. The product should be reported under the following indicated EPA hazard categories:
C o~q r p ._- --- w ..... ...... ...........
X                 Immediate. (Acute) Health HaZard Nalco Company 1601 W. Diehl Road
The Teratogen Information System, University of Washington, Seattle, WA (TOMES CPSTM CD-ROM Version), Micromedex, Inc., Englewood, CO.Prepared By: Product Safety Department Date Issued: 03/0112012 Version Number: 2.2 Nalco Company 1601 W. Diehl Road -Naperville, Illinois 60563-1198  
* Naperville, Illinois 60563-1198 - (630)305-1000 For additional copies of an MSDS visil vvw.nalco.com and request access.
-(630)305-1000 For additional copies of an MSDS visit wvw.nalco.com and request access.10/10 Attachment NOC-AE-14003142 Page 129 of 155 A4.NALCU`&#xfd; SAFETY DATA SHEET PRODUCT NALCO 1359 PLUS.EMERGENCY TELEPHONE NUMBER(S)(800) 424-9300 (24 Hours) CHEMTREC INTERNATIONAL CHEMICAL CONTROL LAWS: CANADIAN ENVIRONMENTAL PROTECTION ACT (CEPA): The substances in this preparation are listed on the Domestic Substances List (DSL), are exempt, or have been reported in accordance with the New Substances Notification Regulations, AUSTRALIA All substances in this product comply with the National Industrial Chemicals Notification  
7110
& Assessment Scheme (NICNAS).EUROPE The substances in this preparation have been reviewed for compliance with the EINECS or ELINCS Inventories.
 
JAPAN All substances In this product comply with the Law Regulating the Manufacture and Importation Of Chemical Substances and are listed on the.Existing and New Chemical Substances list (ENCS).KOREA All substances In this product comply with the Toxic Chemical Control Law (TCCL) and are listed on the Existing Chemicals List (ECL)PHILIPPINES All substances In this product comply with the RepublicAct 6969 (RA 6969) and are listed on the Philippines Inventory of Chemicals  
Attachment NOC-AE-14003142 Page 127 of 155 SAFETY DATA SHEET                                                  7' PIRODUCT
& Chemical Substances (PICGS).116. 1 OTHER INFORMATION Due to our commitment to Product Stewardship, we have evaluated the human and environmental hazards and exposures sef te a si -p r6--.Kwvb  
  &#xfd;q N'AALC(eO%                                     NALCO 1359 PLUS EMERGENCY TELEPHONE NUMSER(S)
.- c.general risk. This Information should provide assistance for your own risk management practices.
(800) 424-9300 (24 Hours) CHEMTREC X               Delayed (Chronic) Health Hazard Fire Hazard Sudden Release of Pressure Hazard Reactive Hazard Under SARA 311 and 312, the EPA has established threshold quantities for the reporting of hazardous chemicals, The current thresholds are: 500 pounds or the threshold planning quantity (TPQ), whichever is lower, for extremely hazardous substances and 10,000 pounds for all other hazardous chemicals.
We have evaluated our product's risk as follows: 'The human risk Is: Moderate* The environmental risk Is: Moderate Any use inconsistent with our recommendations may affect the risk characterization.
_-SECLQFj_3J2,_._.L'O.FTQXJC.. HEM.CALS_..CER,371) "
Our sales representative will assist you to determine if your product application Is consistent with our recommendations.
This product contains the following substance(s), (with CAS # and % range) which appear(s) on the List of Toxic Chemicals Hazardous Substance(s)                                   CAS NO Sodium Nitrite                                           7632-00-0                   10.0- 30.0 TOXIC SUBSTANCES CONTROL ACT (TSCA):
Together we can Implement an appropriate risk management process.This product material safety data sheet provides health and safety information.
The substances in this preparation are Included on or exempted from. the TSCA 8(b) Inventory (40 CFR 710)
The product Is to be used in applications consistent with our product literature.
FEDERAL WATER POLLUTION CONTROL ACT, CLEAN WATER ACT, 40 CFR 401A 5 /formerly Sec, 307,40 CFR 116.4 Iformerly Sec. 311:
Individuals handling this product should be informed of the recommended safety precautions and should have access to this Information.
This product contains the following substances listed in the regulation. Additional components may be unintentionally present at trace levels.
For any other uses, exposures should be evaluated so that appropriate handling practices and training programs can be established to Insure safe workplace operations.
Substance(s)s                                   Citations
Please consult your local sales representative for any further information.
          " Sodium Nitrite                               Sec. 311
REFERENCES Nalco Company 1601 W. Diehl Road -Naperville, Illinois 60563-1198  
          " Sodium Hydroxide 11Ozone Depleting Substances) :
-(630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.9/10 Attachment NOC-AE-14003142 Page 130 of 155 AWNALCO SAFETY DATA SHEET PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)(800) 424-9300 (24 Hours) CHEMTREC 11. 1 CHEMICAL PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME: NALCO 19H APPLICATION:
Substances listed under this regulation are not Intentionally added or expected to be present In this product. Listed components may be present at trace levels.
COMPANY IDENTIFICATION:
CALIFORNIA PROPOSITION 65:
OXYGEN SCAVENGER Nalco Company 1601 W. Diehl Road 60563-1198 EMERGENCY TELEPHONE NUMBER(S):
Substances listedunder California Proposition 65 are not Intentionally added or expected to be present In this product.
(800) 424-9300 (24 Hours) CHEMTREC NFPA 704MIHMIS RATING HEALTH: 2/2' FLAMMABILITY:
MICHIGAN CRITICAL MATERIALS:
III INSTABILITY:
Substances listed under this regulation are not intentionally added or expected to be present in this product. Listed components may be present at trace levels.
0/0 OTHER: 0 = Insignificant 1 = Slight 2 = Moderate 3 = High 4 = Extreme Chronic Health Hazard 12. 1 COMPOSITION/INFORMATION ON INGREDIENTS Our hazard evaluation has Identified the following chemical substance(s) as hazardous.
STATE RIGHT TO KNOW LAWS The following substances are disclosed for compliance with State Right to Know Laws:
Consult Section 15 for the nature of the hazard(s).
Sodium Nitrite                                 7632-00-0 Nalco Company 1601 W. Diehl Road -Naperville, Illinois 60563-1198 - (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.
Hazardous Substance(s)
8110
CAS NO:302-01-2% (w/w)30.0- 60.0 Hydrazine--j-1HAZARDS IDENTIFICATION--  
 
........ ...................  
Attachment NOC-AE-14003142 Page 128 of 155 SAFETY DATA SHEET.
.. ...... .... ... .. ........**EMERGENCY OVERVIEW**
SNALCO                                            PRODUCT NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER(S)
DANGER This product contains hydrazine which is a suspect carcinogen.
(800) 424-9;300 (24 Hours) CHEMTREC Threshold Limit Values for Chemical Substances and Physical Agents and Biological Exposure Indices, American Conference of Governmental Industrial Hygienists, OH., (Arlel InsightTU CD-ROM Version), Arnel Research Corp.,
Extreme health hazard. Toxic by inhalation, in contact with skin and if swallowed.
Bethesda, MD.
Irritating toskin. Risk of serious damage to eyes. May cause sensitization by skin contact. Very toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment.
Hazardous Substances Data Bank, National Library of Medicine, Bethesda, Maryland (TOMES CPS"" CD-ROM Version), Micromedex, Inc., Englewood, CO.
Do not get in eyes, on skin, on clothing.
IARC Monographs on the Evaluation of [he Carcinogenic Risk of Chemicals to Man, Geneva: World Health Organl tio-rlilet to--A- e-c Integrated Risk Information System, U.S. Environmental Protection Agency, Washington, D.C. (TOMES CPSTm CD-ROM Version),
Do not take internally.
Micromedex, Inc., Englewood, CO.
Use with adequate ventilation.
Annual Report on Carcinogens, National Toxicology Program, U.S. Department of Health and HumanServices, Public Health Service.
Keep container tightly closed and in a well-ventilated place. If respiratory symptoms develop, remove to fresh air, rest, treat symptomatically.
Title 29 Code of Federal Regulations, Part 1910, Subpart Z, Toxic and Hazardous Substances. Occupational Safety and Health Administration (OSHA), (Arlel Insightm CD-ROM Version), Ariel Research Corp., Bethesda, MD.
Get medical attention.
Registry of Toxic Effects of Chemical Substances, National Institute for Occupational Safety and Health, Cincinnati, OH, (TOMES CPSTM CD-ROM Version), Micromedex, Inc., Englewood, CO.
In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. After contact with skin, wash immediately with plenty of water. Use a mild soap if available.
Ariel InsightTu (An integrated guide to industrial chemicals covered under major regulatory and advisory programs),
Wear a face shield, Wear chemical resistant apron, chemical splash goggles, impervious gloves and boots.Hydrazine can ignite spontaneously in air in contact with wood, cloth, earth, or other organic materials.
North American Module, Western European Module, Chemical Inventories Module and the Generics Module (Ariel
Heat or contact with strong acid can result In the generation of flammable hydrogen gas. May evolve oxides of nitrogen (NOx)under fire conditions.
.........                                       rC o~q p                 ._- -   -- w . ....                     . ................
May evolve ammonia under fire conditions.
The Teratogen Information System, University of Washington, Seattle, WA (TOMES CPSTM CD-ROM Version),
May evolve toxic gases or fumes under fire conditions.
Micromedex, Inc., Englewood, CO.
Empty product. containers may contain product residue. Do not pressurize, cut, heat, weld, or expose containers to flame or other sources of ignition.
Prepared By: Product Safety Department Date Issued: 03/0112012 Version Number: 2.2 Nalco Company 1601 W. Diehl Road - Naperville, Illinois 60563-1198 - (630)305-1000 For additional copies of an MSDS visit wvw.nalco.com and request access.
Contact with reactive metals (e.g. aluminum) may result In the generation of flammable hydrogen gas.Nalco Company 1601 W. Diehl Road -Naperville, Illinois 60563-1198
10/10
-(630)305-1000 For additional copies of an MSDS visit wAw.nalco.com and request access.1/13 Attachment NOC-AE-14003142 Page 131 of 155 AVNALCO PRIMARY ROUTES OF EXPOSURE: Eye, Skin HUMAN HEALTH HAZARDS -ACUTE: SAFETY DATA SHEET PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)(800) 424-9300 (24 Hours) CHEMTREC EYE CONTACT: Severe!y irritating.
 
If not removed promptly, will Injure eye tissue and may result in permanent eye damage.SKIN CONTACT: Prolonged or frequently repeated skin contact may cause. allergic reactions in some individuals.
Attachment NOC-AE-14003142 Page 129 of 155 SAFETY DATA SHEET A4.NALCU`&#xfd;                                           PRODUCT NALCO 1359 PLUS
Toxic in contact wilh skin. May causesevereit-on or tissue damage depending on the length of exposure and the type of first aid administered.
                                                    .EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours) CHEMTREC INTERNATIONAL CHEMICAL CONTROL LAWS:
CANADIAN ENVIRONMENTAL PROTECTION ACT (CEPA):
The substances in this preparation are listed on the Domestic Substances List (DSL), are exempt, or have been reported in accordance with the New Substances Notification Regulations, AUSTRALIA All substances in this product comply with the National Industrial Chemicals Notification &Assessment Scheme (NICNAS).
EUROPE The substances in this preparation have been reviewed for compliance with the EINECS or ELINCS Inventories.
JAPAN All substances In this product comply with the Law Regulating the Manufacture and Importation Of Chemical Substances and are listed on the.Existing and New Chemical Substances list (ENCS).
KOREA All substances In this product comply with the Toxic Chemical Control Law (TCCL) and are listed on the Existing Chemicals List (ECL)
PHILIPPINES All substances In this product comply with the RepublicAct 6969 (RA 6969) and are listed on the Philippines Inventory of Chemicals &Chemical Substances (PICGS).
116.     1OTHER INFORMATION Due to our commitment to Product Stewardship, we have evaluated the human and environmental hazards and exposures       sef                   te                       a si r6--.Kwvb chirimt*iid~the                  c. .-     -p general risk. This Information should provide assistance for your own risk management practices. We have evaluated our product's risk as follows:
'The human risk Is: Moderate
* The environmental risk Is: Moderate Any use inconsistent with our recommendations may affect the risk characterization. Our sales representative will assist you to determine ifyour product application Is consistent with our recommendations. Together we can Implement an appropriate risk management process.
This product material safety data sheet provides health and safety information. The product Is to be used in applications consistent with our product literature. Individuals handling this product should be informed of the recommended safety precautions and should have access to this Information. For any other uses, exposures should be evaluated so that appropriate handling practices and training programs can be established to Insure safe workplace operations. Please consult your local sales representative for any further information.
REFERENCES Nalco Company 1601 W. Diehl Road - Naperville, Illinois 60563-1198 - (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.
9/10
 
Attachment NOC-AE-14003142 Page 130 of 155 SAFETY DATA SHEET AWNALCO                                            PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours)     CHEMTREC
: 11.       1CHEMICAL PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME:                                         NALCO 19H APPLICATION:                                         OXYGEN SCAVENGER COMPANY IDENTIFICATION:                               Nalco Company 1601 W. Diehl Road 60563-1198 EMERGENCY TELEPHONE NUMBER(S):                       (800) 424-9300 (24 Hours)         CHEMTREC NFPA 704MIHMIS RATING HEALTH:       2/2'       FLAMMABILITY:         III         INSTABILITY:       0/0       OTHER:
0 = Insignificant 1 = Slight 2 = Moderate 3 = High 4 = Extreme                     Chronic Health Hazard
: 12.       1 COMPOSITION/INFORMATION ON INGREDIENTS Our hazard evaluation has Identified the following chemical substance(s) as hazardous. Consult Section 15 for the nature of the hazard(s).
Hazardous Substance(s)                                         CAS NO             % (w/w)
Hydrazine                                                                            :302-01-2          30.0- 60.0
      --j-1HAZARDS IDENTIFICATION--                     ........           .......
                                              **EMERGENCY OVERVIEW**
DANGER This product contains hydrazine which is a suspect carcinogen. Extreme health hazard. Toxic by inhalation, in contact with skin and if swallowed. Irritating toskin. Risk of serious damage to eyes. May cause sensitization by skin contact. Very toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment.
Do not get in eyes, on skin, on clothing. Do not take internally. Use with adequate ventilation. Keep container tightly closed and in a well-ventilated place. If respiratory symptoms develop, remove to fresh air, rest, treat symptomatically. Get medical attention. In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. After contact with skin, wash immediately with plenty of water. Use a mild soap if available.
Wear a face shield, Wear chemical resistant apron, chemical splash goggles, impervious gloves and boots.
Hydrazine can ignite spontaneously in air in contact with wood, cloth, earth, or other organic materials. Heat or contact with strong acid can result Inthe generation of flammable hydrogen gas. May evolve oxides of nitrogen (NOx) under fire conditions. May evolve ammonia under fire conditions. May evolve toxic gases or fumes under fire conditions. Empty product. containers may contain product residue. Do not pressurize, cut, heat, weld, or expose containers to flame or other sources of ignition. Contact with reactive metals (e.g. aluminum) may result In the generation of flammable hydrogen gas.
Nalco Company 1601 W. Diehl Road - Naperville, Illinois 60563-1198 - (630)305-1000 For additional copies of an MSDS visit wAw.nalco.com and request access.
1/13
 
Attachment NOC-AE-14003142 Page 131 of 155 SAFETY DATA SHEET AVNALCO                                            PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours) CHEMTREC PRIMARY ROUTES OF EXPOSURE:
Eye, Skin HUMAN HEALTH HAZARDS - ACUTE:
EYE CONTACT:
Severe!y irritating. If not removed promptly, will Injure eye tissue and may result in permanent eye damage.
SKIN CONTACT:
Prolonged or frequently repeated skin contact may cause. allergic reactions in some individuals. Toxic in contact wilh skin. May causesevereit-on or tissue damage depending on the length of exposure and the type of first aid administered.
INGESTION:
INGESTION:
Not a likely route of exposure.
Not a likely route of exposure. Toxic if swallowed. May cause mucosal damage.
Toxic if swallowed.
INHALATION:
May cause mucosal damage.INHALATION:
Not a likely route of exposure. Toxic by inhalation. Vapors extremely Irritating to eyes and respiratory tract. Can cause pulmonary edema. May cause liver and kidney disorder andlor damage.
Not a likely route of exposure.
SYMPTOMS OF EXPOSURE:
Toxic by inhalation.
Acute:
Vapors extremely Irritating to eyes and respiratory tract. Can cause pulmonary edema. May cause liver and kidney disorder andlor damage.SYMPTOMS OF EXPOSURE: Acute: A review of available data does not Identify any symptoms frorm exposure not previously mentioned.
A review of available data does not Identify any symptoms frorm exposure not previously mentioned.
Chronic: A review of available data does not identify any symptoms from exposure not previously mentioned.
Chronic:
A review of available data does not identify any symptoms from exposure not previously mentioned.
AGGRAVATION OF EXISTING CONDITIONS:
AGGRAVATION OF EXISTING CONDITIONS:
Preexisting eye, skin, and respiratory conditions may be aggravated.
Preexisting eye, skin, and respiratory conditions may be aggravated.
HUMAN HEALTH HAZARDS -CHRONIC: This product contains hydrazine.
HUMAN HEALTH HAZARDS - CHRONIC:
The International Agency for Research on Cancer(IARC) has evaluated hydrazine, and found it to be a possible human carcinogen (Group 28) based on sufficient animal data and inadequate human data. Oral administration of hydrazine has produced lung and liver tumors in mice and rats and mammary tumors in mice. Inhalation of hydrazine has produced nasal tumors in rats.14. 1 FIRST AID MEASURES EYE CONTACT: Get immediate medical attention.
This product contains hydrazine. The International Agency for Research on Cancer(IARC) has evaluated hydrazine, and found it to be a possible human carcinogen (Group 28) based on sufficient animal data and inadequate human data. Oral administration of hydrazine has produced lung and liver tumors in mice and rats and mammary tumors in mice. Inhalation of hydrazine has produced nasal tumors in rats.
PROMPT ACTION IS ESSENTIAL IN CASE OF CONTACT. Immediately flush eye with water for at least 15 minutes while holding eyelids open.SKIN CONTACT: Get Immediate medical attention.
: 14.       1 FIRST AID MEASURES EYE CONTACT:
Immediately flush with plenty of water for at least 15 minutes. For a large splash, flood body under a shower. Remove contaminated clothing.
Get immediate medical attention. PROMPT ACTION IS ESSENTIAL IN CASE OF CONTACT. Immediately flush eye with water for at least 15 minutes while holding eyelids open.
Wash off affected area immediately with plenty of water.Contaminated clothing, shoes, and leather goods must be discarded or cleaned before re-use.Nalco Company 1601 W. Diehl Road -Naperville, Illinois 60563-1198  
SKIN CONTACT:
-(630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.2/13 Attachment NOC-AE-14003142 Page 132 of 155 PWNALCO SAFETY DATA SHEET PRODUCT NALCOO 19H EMERGENCY TELEPHONE NUMBER(S)(800) 424-9300 (24 Hours) CHEMTREC INGESTION:
Get Immediate medical attention. Immediately flush with plenty of water for at least 15 minutes. For a large splash, flood body under a shower. Remove contaminated clothing. Wash off affected area immediately with plenty of water.
DO NOT INDUCE VOMITING.
Contaminated clothing, shoes, and leather goods must be discarded or cleaned before re-use.
If conscious, washout mouth and give water to drink. Get immediate medical attention.
Nalco Company 1601 W. Diehl Road - Naperville, Illinois 60563-1198 - (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.
2/13
 
Attachment NOC-AE-14003142 Page 132 of 155 SAFETY DATA SHEET PWNALCO                                            PRODUCT NALCOO 19H EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours) CHEMTREC INGESTION:
DO NOT INDUCE VOMITING. If conscious, washout mouth and give water to drink. Get immediate medical attention.
INHALATION:
INHALATION:
Remove to fresh air, treat symptomatically.
Remove to fresh air, treat symptomatically. Get medical attention.
Get medical attention.
NOTE TO PHYSICIAN:
NOTE TO PHYSICIAN:
Probable mucosal damage may contraindicate the use of gastric lavage. Based on the individual reactions of the patient, the physician's judgement should be used to control symptoms and clinical condition.
Probable mucosal damage may contraindicate the use of gastric lavage. Based on the individual reactions of the patient, the physician's judgement should be used to control symptoms and clinical condition.
: 5. FIRE FIGHTING MEASURES FLASH POINT: > 230 F/1 > 110 'C (PMCC)EXTINGUISHING MEDIA: Not expected to bum. Use extinguishing media appropriate for surrounding fire.FIRE AND EXPLOSION HAZARD: Hydrazine can ignite spontaneously in air in contact with wood, cloth, earth, or other organicmaterials.
: 5.         FIRE FIGHTING MEASURES FLASH POINT:                                 > 230 F/1 > 110 'C (PMCC)
Heat or contact with strong acid can result in the generation of flammable hydrogen gas, May evolve oxides of nitrogen (NOx) under fire conditions.
EXTINGUISHING MEDIA:
May evolve ammonia under fire conditions.
Not expected to bum. Use extinguishing media appropriate for surrounding fire.
May evolve toxic gases or fumes under fire conditions.
FIRE AND EXPLOSION HAZARD:
Empty product containers may contain product residue. Do not pressurize, cut, heat., weld, or expose containers to flame or other sources of ignition.
Hydrazine can ignite spontaneously in air in contact with wood, cloth, earth, or other organicmaterials. Heat or contact with strong acid can result in the generation of flammable hydrogen gas, May evolve oxides of nitrogen (NOx) under fire conditions. May evolve ammonia under fire conditions. May evolve toxic gases or fumes under fire conditions.
Contact with reactive metals (e.g. aluminum) may result in the generation of flammable hydrogen gas.SPECIAL:PROTECTIVE EQUIPMENT FOR FIRE FIGHTING: In case of fire, wear a full face positive-pressure self contained breathing apparatus and protective suit.6. ACCIDENTAL RELEASE MEASURES PERSONAL PRECAUTIONS:
Empty product containers may contain product residue. Do not pressurize, cut, heat., weld, or expose containers to flame or other sources of ignition. Contact with reactive metals (e.g. aluminum) may result in the generation of flammable hydrogen gas.
Restrict access to area as appropriate until clean-up operations are complete.
SPECIAL:PROTECTIVE EQUIPMENT FOR FIRE FIGHTING:
Use personal, protective equipment recommended In Section 8 (Exposure Controls/Personal Protection).
In case of fire, wear a full face positive-pressure self contained breathing apparatus and protective suit.
Stop or reduce any leaks if it is safe to do so.Ventilate spill area if possible.
: 6.         ACCIDENTAL RELEASE MEASURES PERSONAL PRECAUTIONS:
Remove sources of ignition.
Restrict access to area as appropriate until clean-up operations are complete. Use personal, protective equipment recommended In Section 8 (Exposure Controls/Personal Protection). Stop or reduce any leaks if it is safe to do so.
Ensure clean-up is conducted by trained personnel only.Do not touch spilled material.
Ventilate spill area if possible. Remove sources of ignition. Ensure clean-up is conducted by trained personnel only.
Have emergency equipment (for fires, spills, leaks, etc.) readily available.
Do not touch spilled material. Have emergency equipment (for fires, spills, leaks, etc.) readily available. Notify appropriate government, occupational health and safety and environmental authorities.
Notify appropriate government, occupational health and safety and environmental authorities.
METHODS FOR CLEANING UP.
METHODS FOR CLEANING UP.SMALL SPILLS: Do not clean up spills with sawdust, cotton waste or other combustible absorbent materials.
SMALL SPILLS: Do not clean up spills with sawdust, cotton waste or other combustible absorbent materials. Create a dike or trench to contain material. Dilute spilled material to about 10% hydrazine with water. Neutralize the diluted hydrazineby slowly adding a 5-8% calcium hypochlorite or sodium hypochlorite (bleach) solution until all the hydrazine has been reacted. Steam and nitrogen gas will be evolved. DO NOT ADD DRY CALCIUM OR SODIUM HYPOCHLORITE TO A HYDRAZINE SPILL. A VIOLENT REACTION MAY RESULT. The neutralized material may be absorbed using clay, sand or commercial absorbent. Shovel reclaimed liquid and absorbent into recovery or salvage drums for disposal, Refer to CERCLA Section 15. Contact of the unneutralized product with certain clays may lead to hydrazine decomposition and release of ammonia. Contact an approved waste hauler for disposal of contaminated Nalco Company 1601 W. Diehl Road
Create a dike or trench to contain material.
* Naperville, Illinois 60563-1198 * (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.
Dilute spilled material to about 10% hydrazine with water. Neutralize the diluted hydrazineby slowly adding a 5-8% calcium hypochlorite or sodium hypochlorite (bleach) solution until all the hydrazine has been reacted. Steam and nitrogen gas will be evolved. DO NOT ADD DRY CALCIUM OR SODIUM HYPOCHLORITE TO A HYDRAZINE SPILL. A VIOLENT REACTION MAY RESULT. The neutralized material may be absorbed using clay, sand or commercial absorbent.
3/13
Shovel reclaimed liquid and absorbent into recovery or salvage drums for disposal, Refer to CERCLA Section 15. Contact of the unneutralized product with certain clays may lead to hydrazine decomposition and release of ammonia. Contact an approved waste hauler for disposal of contaminated Nalco Company 1601 W. Diehl Road
 
* Naperville, Illinois 60563-1198  
Attachment NOC-AE-14003142 Page 133 of 155 SAFETY DATA SHEET N4 NALC0                                          PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)
* (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.3/13 Attachment NOC-AE-14003142 Page 133 of 155 N4 NALC0 SAFETY DATA SHEET PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)(800) 424-9300 (24 Hours) CHEMTREC recovered material.
(800) 424-9300 (24 Hours) CHEMTREC recovered material. LARGE SPILLS: Dike to prevent further movement. Dispose of material in compliance with regulations indicated in Section 13 (Disposal Considerations).
LARGE SPILLS: Dike to prevent further movement.
Dispose of material in compliance with regulations indicated in Section 13 (Disposal Considerations).
ENVIRONMENTAL PRECAUTIONS:
ENVIRONMENTAL PRECAUTIONS:
Do not contaminate surface water.17. 1 HANDLING AND STORAGE HANDLING: Do not get In eyes, on skin, on clothing.
Do not contaminate surface water.
Do not take internally.
: 17.       1HANDLING AND STORAGE HANDLING:
Use with adequate ventilation.
Do not get In eyes, on skin, on clothing. Do not take internally. Use with adequate ventilation. Do not breathe vaporsigasesldust. Keep the containers closed when not in use. Have emergency equipment (for fires, spills, leaks, etc.) readily available. Ensure all containers are labeled. Do not mix with acids. Do not use, store, spill or pour near heat, sparks or open flame. Handle the material under an inert atmosphere of nitrogen or argon.
Do not breathe vaporsigasesldust.
STORAGE CONDITIONS:
Keep the containers closed when not in use. Have emergency equipment (for fires, spills, leaks, etc.) readily available.
Store the containers tightly closed. Store separately from oxidizers. Store away from organic materials. Store in suitable labeled containers. Store away from heat and sources of ignition. Keep away from light, direct sunlight.
Ensure all containers are labeled. Do not mix with acids. Do not use, store, spill or pour near heat, sparks or open flame. Handle the material under an inert atmosphere of nitrogen or argon.STORAGE CONDITIONS:
Empty spaces in tanks must be filled by inert atmosphere.
Store the containers tightly closed. Store separately from oxidizers.
SUITABLE CONSTRUCTION MATERIAL:
Store away from organic materials.
Polypropylene, Polyethylene, Stainless Steel 304, Stainless Steel 316L, Compatibility with Plastic Materials can vary; we therefore recommend that compatibility is tested prior to use.
Store in suitable labeled containers.
UNSUITABLE CONSTRUCTION MATERIAL:
Store away from heat and sources of ignition.
Copper, Brass, Aluminum Ef8--iEXPOSURE CONTRO*LOIPES*iiNC--IPROTECTION OCCUPATIONAL EXPOSURE LIMITS:
Keep away from light, direct sunlight.Empty spaces in tanks must be filled by inert atmosphere.
Exposure guidelines have not been established for this, product, Available exposure limits for the substance(s) are
SUITABLE CONSTRUCTION MATERIAL: Polypropylene, Polyethylene, Stainless Steel 304, Stainless Steel 316L, Compatibility with Plastic Materials can vary;we therefore recommend that compatibility is tested prior to use.UNSUITABLE CONSTRUCTION MATERIAL: Copper, Brass, Aluminum Ef8--iEXPOSURE  
:shown below.
......OCCUPATIONAL EXPOSURE LIMITS: Exposure guidelines have not been established for this, product, Available exposure limits for the substance(s) are:shown below.Substance(s)
Substance(s)                                       CatagofV:                       ppm Unit Hydrazine                                          ACGIHITWA                       0.01 ACGII-tSkln' OSHA ZI/PEL                       1            1.3 0SHA Z1/SkhV*
Hydrazine CatagofV: ACGIHITWA ACGII-tSkln' OSHA ZI/PEL 0SHA Z1/SkhV*ppm 0.01 1 Unit 1.3* Can be absorbed through the skin.ENGINEERING MEASURES: General ventilation Is recommended.
* Can be absorbed through the skin.
Use local exhaust ventilation If necessary to control airborne mist and vapor.Nalco Company 1601 W. Diehl Road -Naperville, Illinois 60563-1198  
ENGINEERING MEASURES:
* (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.4113 Attachment NOC-AE-14003142 Page 134 of 155~N ALCO SAFETY DATA SHEET PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)(800) 424-9300(24 Hours) CHEMTREC RESPIRATORY PROTECTION:
General ventilation Is recommended. Use local exhaust ventilation If necessary to control airborne mist and vapor.
Nalco Company 1601 W. Diehl Road - Naperville, Illinois 60563-1198 * (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.
4113
 
Attachment NOC-AE-14003142 Page 134 of 155 SAFETY DATA SHEET PRODUCT
        ~N    ALCO                                    NALCO 19H EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300(24 Hours) CHEMTREC RESPIRATORY PROTECTION:
Where concentrations in air may exceed the limits given in this section or when significant mists, vapors, aerosols, or dusts are generated, an approved air purifying respirator equippedwith suitable filter cartridges Is recommended.
Where concentrations in air may exceed the limits given in this section or when significant mists, vapors, aerosols, or dusts are generated, an approved air purifying respirator equippedwith suitable filter cartridges Is recommended.
consult the respirator  
consult the respirator / cartridge manufacturer data to verify the suitability of specific devices. In event of emergency of planned entry Into unknown concentrations a positive pressurefull-facepiece SCBA should be used. Ifrespiratory protection is required, institute a complete respiratory protection program including selection, fit testing, training, maintenance and inspection.
/ cartridge manufacturer data to verify the suitability of specific devices. In event of emergency of planned entry Into unknown concentrations a positive pressurefull-facepiece SCBA should be used. If respiratory protection is required, institute a complete respiratory protection program including selection, fit testing, training, maintenance and inspection.
HAND PROTECTION:
HAND PROTECTION:
When handling this product, the use of chemical gloves is recommended.
When handling this product, the use of chemical gloves is recommended. The choice of work glove depends on work conditionsand what chemicals are handled. Please contact the PPE manufacturer fo" advice on what type of glove material may be suitable. Gloves should be replaced immediately if signs of degradation are observed.
The choice of work glove depends on work conditionsand what chemicals are handled. Please contact the PPE manufacturer fo" advice on what type of glove material may be suitable.
SKIN PROTECTION:
Gloves should be replaced immediately if signs of degradation are observed.SKIN PROTECTION:
Wear chemical resistant apron, chemical splash goggles, impervious gloves and boots. A full slicker suit is recommended ifgross exposure is possible.
Wear chemical resistant apron, chemical splash goggles, impervious gloves and boots. A full slicker suit is recommended if gross exposure is possible.EYE PROTECTION:
EYE PROTECTION:
Wear a face shield with chemical splash goggles.HYGIENE RECOMMENDATIONS:
Wear a face shield with chemical splash goggles.
Use good work and personal hygiene practices to avoid exposure.
HYGIENE RECOMMENDATIONS:
Keep an eye wash fountain available.
Use good work and personal hygiene practices to avoid exposure. Keep an eye wash fountain available. Keep a safety shower available. Ifclothing is contaminated, remove clothing and thoroughly wash the affected area. Launder contaminated clothing before reuse. Always wash thoroughly after handling chemicals. When handling this product never eat, drink or smoke.
Keep a safety shower available.
I 9.       I PHYSICAL AND CHEMICAL PROPERTIES                                                                                 I APPEARANCE                     Colorless ODOR                           Ammonlacal SPECIFIC GRAVITY                         1.03 @ 60 F115.6 -C DENSITY                                  8.56 Ib/gal SOLUBILITY IN WATER                      Complete pH (100/%)                                12.5 pH (1 %)                                  10.1.- 10.7 VISCOSITY                                2.0 cps @ 60 =F 115.6 *C FREEZING POINT                            -85 IF -65 'C BOILING POINT                            228 OF / 108.9 OC VAPOR PRESSURE                            22mmHg @ 77&deg;F125&deg;C Note: These physical properties are typical values for this product and are subject to change.
If clothing is contaminated, remove clothing and thoroughly wash the affected area. Launder contaminated clothing before reuse. Always wash thoroughly after handling chemicals.
Nalco Company 1601 W. Diehl Road
When handling this product never eat, drink or smoke.I 9. I PHYSICAL AND CHEMICAL PROPERTIES I.....APPEARANCE ODOR Colorless Ammonlacal SPECIFIC GRAVITY DENSITY SOLUBILITY IN WATER pH (100/%)pH (1 %)VISCOSITY FREEZING POINT BOILING POINT VAPOR PRESSURE 1.03 @ 60 F115.6 -C 8.56 Ib/gal Complete 12.5 10.1.- 10.7 2.0 cps @ 60 =F 115.6 *C-85 IF -65 'C 228 OF / 108.9 OC 22mmHg @ 77&deg;F125&deg;C Note: These physical properties are typical values for this product and are subject to change.Nalco Company 1601 W. Diehl Road
* Naperville, Illinois 60563-1198 - (630)305-1000 For additional copies of an MSDS visit www.nalco.coni and request access.
* Naperville, Illinois 60563-1198  
5/13
-(630)305-1000 For additional copies of an MSDS visit www.nalco.coni and request access.5/13 Attachment NOC-AE-14003142 Page 135 of 155 P NALCO SAFETY DATA SHEET PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)(800) 424-9300,(24 Hours) CHEMTREC 11. 1STABILITY AND REACTIVITY__
 
Attachment NOC-AE-14003142 Page 135 of 155 SAFETY DATA SHEET P NALCO                                          PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300,(24 Hours) CHEMTREC
: 11.       1STABILITY AND REACTIVITY__
STABILITY:
STABILITY:
Stable if kept under conditions specified in Section 7, HANDLING AND STORAGE.HAZARDOUS POLYMERIZATION:
Stable if kept under conditions specified in Section 7, HANDLING AND STORAGE.
Hazardous polymerization will not occur.____C_ ONJ0[SJDcLTO_
HAZARDOUS POLYMERIZATION:
lD-Q 1-___Extremes of temperature Heat and sources of ignition Including static discharges.
Hazardous polymerization will not occur.
Keep at temperature not exceeding 123 TF MATERIALS TO AVOID: Acids Contact with strong acids (e.g. sulfuric, phosphoric, nitric, hydrochloric, chromic, suffonic) may generate heat, splattering or boiling and toxic vapors. Contact with strong oxidizers (eg. chlorine, peroxides, chromates, nitric acid, perchlorate, concentrated oxygen, permanganate) may generate heat, fires, explosions and/or toxic vapors. Organic materials Gives off hydrogen by reaction with metals. Avoid contact with metal oxides such as those of iron, copper, lead, manganese and molybdenum.
____C_                 ONJ0[SJDcLTO_             lD-Q 1-___
Such contact may lead to decomposition.
Extremes of temperature Heat and sources of ignition Including static discharges.
HAZARDOUS DECOMPOSITION PRODUCTS: Under fire conditions:
Keep at temperature not exceeding           123 TF MATERIALS TO AVOID:
Oxides of nitrogen, ammonia, Flammable gases/vapors
Acids Contact with strong acids (e.g. sulfuric, phosphoric, nitric, hydrochloric, chromic, suffonic) may generate heat, splattering or boiling and toxic vapors. Contact with strong oxidizers (eg. chlorine, peroxides, chromates, nitric acid, perchlorate, concentrated oxygen, permanganate) may generate heat, fires, explosions and/or toxic vapors. Organic materials Gives off hydrogen by reaction with metals. Avoid contact with metal oxides such as those of iron, copper, lead, manganese and molybdenum. Such contact may lead to decomposition.
: 11. TOXICOLOGICAL INFORMATION The following results are for the product...................C .IE.Q L _TOXl Q. LTY z *.Species:
HAZARDOUS DECOMPOSITION PRODUCTS:
a LD50: 185 mg/kg Test Descriptor:
Under fire conditions:             Oxides of nitrogen, ammonia, Flammable gases/vapors
Product ACUTE DERMAL TOXICITY: Species: Rabbit LD50: 420 mg/kg Test Descriptor:
: 11.       TOXICOLOGICAL INFORMATION The following results are for the product.
Product ACUTE INHALATION TOXICITY: Species: Rat LC50: 2.1 mg/I (4 hrs)Test Descriptor; Product SENSITIZATION:
.................. *,.C .IE.Q8* L _TOXl Q.LTY *
May cause sensitization by skin contact.Nalco Company 1601 W. Diehl Road Napervilie, Illinois 60563-1198  
.Species:
-(630)305-1000 For additional copies of an MSDS visit vvww.nalco.com and request access.6/13 Attachment NOC-AE-14003142 Page 136 of 155 r-4NA LCO SAFETY DATA SHEET PRODUCT NALCO 19H EMERGENCY.TELEPHONE NUMBER(S)(800) 424-9300 (24 Hours) CHEMTREC CARCINOGENICITY:
z a
LD50:                     185 mg/kg Test Descriptor:           Product ACUTE DERMAL TOXICITY:
Species:                 Rabbit LD50:                     420 mg/kg Test Descriptor:           Product ACUTE INHALATION TOXICITY:
Species:                 Rat LC50:                     2.1 mg/I (4 hrs)
Test Descriptor;         Product SENSITIZATION:
May cause sensitization by skin contact.
Nalco Company 1601 W. Diehl Road Napervilie, Illinois 60563-1198 - (630)305-1000 For additional copies of an MSDS visit vvww.nalco.com and request access.
6/13
 
Attachment NOC-AE-14003142 Page 136 of 155 SAFETY DATA SHEET r-4NA LCO                                         PRODUCT NALCO 19H EMERGENCY.TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours) CHEMTREC CARCINOGENICITY:
This product contains hydrazine, The International Agency for Research on Cancer(IARC) has evaluated hydrazine, and found it to be a possible human carcinogen (Group 2B) based on sufficient animal data and inadequate human data, MUTAGENICITY:
This product contains hydrazine, The International Agency for Research on Cancer(IARC) has evaluated hydrazine, and found it to be a possible human carcinogen (Group 2B) based on sufficient animal data and inadequate human data, MUTAGENICITY:
An ingredient in this product has shown positive results in a screening test for mutagenicity.
An ingredient in this product has shown positive results in a screening test for mutagenicity.
-4IHUMAN-,AZARD-CHARACTERIZAT4.0N Based on our hazard characterization, the potential human hazard is: High 112. 1 ECOLOGICAL INFORMATION ECOTOXICOLOGICAL EFFECTS: The following results are for the product.Acute Fish Results _Species Exposure Test Type Value Test Descriptor Bluegill Sunfish 96 hrs LC50 4.2 mg/I Product Rainbow Trout 96 hrs LC50 4.3 mg/I Product Gold Orfe 96 hrs LC50 0.75 mg l Product ACUTE INVERTEBRATE RESULTS: Species Exposure Test Type Value Test Descriptor Daphnia magna 48 hrs LC50 0.46 mg/1 Product PERSISTENCY AND DEGRADATION:
- 4IHUMAN-,AZARD-CHARACTERIZAT4.0N Based on our hazard characterization, the potential human hazard is: High 112.       1 ECOLOGICAL INFORMATION ECOTOXICOLOGICAL EFFECTS:
The following results are for the product.
Acute Fish Results                 _
Species                            Exposure       Test Type       Value             Test Descriptor Bluegill Sunfish                   96 hrs           LC50             4.2 mg/I         Product Rainbow Trout                     96 hrs           LC50             4.3 mg/I         Product Gold Orfe                           96 hrs         LC50             0.75 mg l         Product ACUTE INVERTEBRATE RESULTS:
Species                             Exposure       Test Type       Value             Test Descriptor Daphnia magna                     48 hrs           LC50             0.46 mg/1         Product PERSISTENCY AND DEGRADATION:
The organic portion of this preparation is expected to be readily biodegradable.
The organic portion of this preparation is expected to be readily biodegradable.
MOBILITY: The environmental fate was estimated using a level III fugacity model embedded in the EPI (estimation program interface)
MOBILITY:
Suite TM, provided by the US EPA. The model assumes a steady state condition between the total input and output. The level lIlImodel does not require equilibrium between the defined media. The information provided is intended to give the user a general estimate of the environmental fate of this product under the defined conditions of the models.If released Into the environment this material Is expected to distribute to the air, water and soil/sediment in the approximate respective percentages; Air W ater. Soil/Sediment 30 -50% 50- 70%The portion in water is expected to be soluble or dispersible.
The environmental fate was estimated using a level III fugacity model embedded in the EPI (estimation program interface) Suite TM, provided by the US EPA. The model assumes a steady state condition between the total input and output. The level lIlImodel does not require equilibrium between the defined media. The information provided is intended to give the user a general estimate of the environmental fate of this product under the defined conditions of the models.
Nalco Company 1601 W. Diehl Road Naperville, Illinois 60563-1198  
If released Into the environment this material Is expected to distribute to the air, water and soil/sediment in the approximate respective percentages; Air                     Water.             Soil/Sediment 30 - 50%               50- 70%
-(630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access, 7/13 Attachment NOC-AE-14003142 Page 137 of 155 NNALCO SAFETY DATA SHEET PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)(800) 424-9300 (24 Hours) CHEMTREC BIOACCUMULATION POTENTIAL This preparation or material Is not expected to bloaccumulate.
The portion in water is expected to be soluble or dispersible.
ENVIRONMENTAL HAZARD AND EXPOSURE CHARACTERIZATION Based on our hazard characterization, the potential environmental hazard is: High If released Into the environment, see CERCLA/SUPERFUND in Section 15.I 13. I DISPOSAL CONSIDERATIONS I If this product becomes a waste, it could meet the criteria of a hazardous waste as defined by the Resource Conservation and Recovery Act (RCRA) 40 CFR 261, Before disposal, it should be determined if the waste meets the criteria of a hazardous waste.Hazardous Waste: D002, U133 Hazardous wastes must be transported by a licensed hazardous waste transporter and disposed of or treated in a properly licensed hazardous waste treatment, storage, disposal.
Nalco Company 1601 W. Diehl Road Naperville, Illinois 60563-1198 - (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access, 7/13
or recycling facility.
 
Consult local, state, and federal regulations for specific requirements.
Attachment NOC-AE-14003142 Page 137 of 155 SAFETY DATA SHEET NNALCO                                          PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)
Contact of the unneutralized product with certain clays may lead to hydrazine decomposition and release of ammonia.I 4. I TRANSPORT INFORMATION I The information in this section is for reference only and should not take the place of a shipping paper (bill of lading)specific to an order. Please note that the proper Shipping Name I Hazard Class may vary by packaging, properties, and mode of transportation.
(800) 424-9300 (24 Hours) CHEMTREC BIOACCUMULATION POTENTIAL This preparation or material Is not expected to bloaccumulate.
Typical Proper Shipping Names for this product are as follows.7--:r.-Thee pres-ence-uaanyR.Q -mmp-nedepoe:uant UtShEPkand  
ENVIRONMENTAL HAZARD AND EXPOSURE CHARACTERIZATION Based on our hazard characterization, the potential environmental hazard is: High If released Into the environment, see CERCLA/SUPERFUND in Section 15.
:D(),imthLsproduct-cause s-lttoe regulated with an additional description of RO for road, or as a class 9 for road and air, ONLY when the net weight in the package exceeds the calculated RQ for the product.LAND TRANSPORT:
I 13.       I DISPOSAL CONSIDERATIONS                                                                                       I If this product becomes a waste, it could meet the criteria of a hazardous waste as defined by the Resource Conservation and Recovery Act (RCRA) 40 CFR 261, Before disposal, it should be determined if the waste meets the criteria of a hazardous waste.
Proper Shipping Name: Technical Name(s): UN/ID No: Hazard Class -Primary: Packing Group: Flash Point: Reportable Quantity (per package): RQ Component:
Hazardous Waste: D002, U133 Hazardous wastes must be transported by a licensed hazardous waste transporter and disposed of or treated in a properly licensed hazardous waste treatment, storage, disposal. or recycling facility. Consult local, state, and federal regulations for specific requirements. Contact of the unneutralized product with certain clays may lead to hydrazine decomposition and release of ammonia.
HYDRAZINE, AQUEOUS SOLUTION UN 3293 6.1 III> 110'&deg;C /,> 230 &deg;F 3 lbs HYDRAZINE I AIR TRANSPORT (ICAO!IATA):
I   4.     I TRANSPORT INFORMATION                                                                                         I The information in this section is for reference only and should not take the place of a shipping paper (bill of lading) specific to an order. Please note that the proper Shipping Name I Hazard Class may vary by packaging, properties, and mode of transportation. Typical Proper Shipping Names for this product are as follows.
Nalco Company 1601 W. Diehl Road Naperville, Illinois 60563-1198  
7--:r.-Thee pres-ence-uaanyR.Q -mmp-nedepoe:uant                     UtShEPkand :D(),imthLsproduct-cause s-lttoe regulated with an additional description of RO for road, or as a class 9 for road and air, ONLY when the net weight in the package exceeds the calculated RQ for the product.
* (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.8113 Attachment NOC-AE-14003142 Page 138 of 155"'NALCO SAFETY DATA SHEET PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)(800) 424-9300 (24 Hours) CHEMTREC The presence of an RQ component (Reportable Quantity for U.S. EPA and DOT) In this product causes it to be regulated with an additional description of RO for road, or as a class 9 for road and air, ONLY when the net weight in.the package exceeds the calculated RQ'for the product.Proper Shipping Name: Technical Name(s): UN/ID No: Hazard Class -Primary: Packing Group: HYDRAZINE, AQUEOUS SOLUTION UN 3293.6.1 Ill[ifJ RQ Component:
LAND TRANSPORT:
MARINE TRANSPORT (IMDG/IMO):
Proper Shipping Name:                         HYDRAZINE, AQUEOUS SOLUTION Technical Name(s):
HYDRAZINE Proper Shipping Name: Technical Name(s): UN/ID No: Hazard Class -Primary: Packing Group: Marine Pollutant:
UN/ID No:                                     UN 3293 Hazard Class - Primary:                       6.1 Packing Group:                               III Flash Point:                                 > 110'&deg;C /,> 230 &deg;F Reportable Quantity (per package):            3 lbs RQ Component:                                HYDRAZINE I AIR TRANSPORT (ICAO!IATA):
HYDRAZINE, AQUEOUS SOLUTION UN 3293 6,1 IHI HYDRAZINE*Note: This product is regulated as a Marine Pollutant when shipped by Rail, Highway (in bulk quantities), or Air (if no other hazard class applies), and when shipped by water in all quantities.
Nalco Company 1601 W. Diehl Road Naperville, Illinois 60563-1198 * (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.
I 15. 1 REGULATORY INFORMATION I.. ...... -,.--.T~his~section..contalns.additional~inforrnaUon~that-nmy-ay erlvnd~o ]a(y z-bnom p-nh..... is or It is not exhaustive, and should not be relied upon to take the place of an Individualized compliance or hazard assessment.
8113
Nalco accepts no liability for the use of this information.
 
NATIONAL REGULATIONS, USA: OSHA HAZARD COMMUNICATION RULE, 29 CFR 1910.1200:
Attachment NOC-AE-14003142 Page 138 of 155 SAFETY DATA SHEET
*Based on our hazard evaluation, the following substance(s) in this product isWare hazardous and the reason(s) islare.shown below.Hydrazine  
            "'NALCO                                             PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)
: Cancer suspect agent (refer to Section 3), Corrosive, Dermal Sensitizer CERCLA/SUPERFUND, 40 CFR 302:*This product contains the following Reportable Quantity (RQ) Substance.
(800) 424-9300 (24 Hours) CHEMTREC The presence of an RQ component (Reportable Quantity for U.S. EPA and DOT) In this product causes it to be regulated with an additional description of RO for road, or as a class 9 for road and air, ONLY when the net weight in.
Also listed is the RQ for the product. If a reportable quantity of product is released, it requires notification to the NATIONAL RESPONSE CENTER, WASHINGTON, D.C. (1-800-424-8802).
the package exceeds the calculated RQ'for the product.
RQ Substance Hydrazine 3 lbs Nalco Company 1601 W. Diehl Road .Naperville, Illinois 60563-1198-(630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.9/13 Attachment NOC-AE-14003142 Page 139 of 155 N"NALCO SAFETY DATA SHEET PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(SY (800) 424-9300 (24 Hours) CHEMTREC I I I I SARAISUPERFUND AMENDMENTS AND REAUTHORIZATION ACT OF 1986 (TITLE t11) -SECTIONS 302, 311, 312, AND 313: SECTION 302 -EXTREMELY HAZARDOUS SUBSTANCES (40 CFR 355): This product contains the following substance(s) which is listed in Appendix A and B as an Extremely Hazardous Substance.
Proper Shipping Name:                               HYDRAZINE, AQUEOUS SOLUTION Technical Name(s):
Listed below are the statutory Threshold Planning Quantity (TPQ) for the substance(s) and the Reportable Quantity (RO) of the product. If a reportable quantity of product is released, it requires notification to your State Fmerg ny-Response-Commisso--Y-ou-may-also-be-require:l~o-notifythe.Naona .Response.Center.See CERCLAISUPERFUND, above.Extremely Hazardous Substance TPQ R.Q Hydrazine 1,000 lbs 3 lbs SECTIONS 311 AND 312 -MATERIAL SAFETYDATA SHEET REQUIREMENTS (40 CFR 3701': Our hazard evaluation has found this product to be hazardous.
UN/ID No:                                           UN 3293 Hazard Class - Primary:                             .6.1 Packing Group:                                      Ill
The product should be reported under the following indicated EPA hazard categories:
[ifJ t*
X Immediate (Acute) Health Hazard X Delayed (Chronic)
RQ Component:                                       HYDRAZINE MARINE TRANSPORT (IMDG/IMO):
Health Hazard Fire Hazard Sudden Release of Pressure Hazard Reactive Hazard Under SARA 311 and 312, the EPA has established threshold quantities for the reporting of hazardous chemicals.
Proper Shipping Name:                                 HYDRAZINE, AQUEOUS SOLUTION Technical Name(s):
UN/ID No:                                             UN 3293 Hazard Class - Primary:                             6,1 Packing Group:                                       IHI Marine Pollutant:                                   HYDRAZINE
        *Note: This product is regulated as a Marine Pollutant when shipped by Rail, Highway (in bulk quantities), or Air (if no other hazard class applies), and when shipped by water in all quantities.
I 15.       1REGULATORY INFORMATION                                                                                             I
-,.--.T~his~section..contalns.additional~inforrnaUon~that-nmy-ay         erlvnd~o         ]a(y             z-bnom p-nh
      ..... is or refer*nce'          It is not exhaustive, and should not be relied upon to take the place of an Individualized compliance or hazard assessment. Nalco accepts no liability for the use of this information.
NATIONAL REGULATIONS, USA:
OSHA HAZARD COMMUNICATION RULE, 29 CFR 1910.1200:
        *Based on our hazard evaluation, the following substance(s) in this product isWare hazardous and the reason(s) islare
        .shown below.
Hydrazine : Cancer suspect agent (refer to Section 3), Corrosive, Dermal Sensitizer CERCLA/SUPERFUND, 40 CFR 302:
        *This product contains the following Reportable Quantity (RQ) Substance. Also listed is the RQ for the product. Ifa reportable quantity of product is released, it requires notification to the NATIONAL RESPONSE CENTER, WASHINGTON, D.C. (1-800-424-8802).
RQ Substance Hydrazine                                                         3 lbs Nalco Company 1601 W. Diehl Road . Naperville, Illinois 60563-1198- (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.
9/13
 
Attachment NOC-AE-14003142 Page 139 of 155 SAFETY DATA SHEET N"NALCO                                           PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(SY (800) 424-9300 (24 Hours) CHEMTREC I
SARAISUPERFUND AMENDMENTS AND REAUTHORIZATION ACT OF 1986 (TITLE t11)- SECTIONS 302, 311, 312, AND 313:
SECTION 302 - EXTREMELY HAZARDOUS SUBSTANCES (40 CFR 355):
This product contains the following substance(s) which is listed in Appendix A and B as an Extremely Hazardous Substance. Listed below are the statutory Threshold Planning Quantity (TPQ) for the substance(s) and the Reportable Quantity (RO) of the product. If a reportable quantity of product is released, it requires notification to your State Fmerg ny-Response-Commisso--Y-ou-may-also-be-require:l~o-notifythe.Naona .Response.Center.See CERCLAISUPERFUND, above.
Extremely Hazardous Substance                                 TPQ                           R.Q Hydrazine                                                     1,000 lbs                     3 lbs SECTIONS 311 AND 312 -MATERIAL SAFETYDATA SHEET REQUIREMENTS (40 CFR 3701':
Our hazard evaluation has found this product to be hazardous. The product should be reported under the following indicated EPA hazard categories:
X               Immediate (Acute) Health Hazard X               Delayed (Chronic) Health Hazard Fire Hazard Sudden Release of Pressure Hazard Reactive Hazard Under SARA 311 and 312, the EPA has established threshold quantities for the reporting of hazardous chemicals.
The current thresholds are: 500 pounds or the threshold planning quantity (TPQ), whichever is lower, for extremely hazardous substances and 10,000 pounds for all other hazardous chemicals.
The current thresholds are: 500 pounds or the threshold planning quantity (TPQ), whichever is lower, for extremely hazardous substances and 10,000 pounds for all other hazardous chemicals.
SECTION 313 -LIST OF TOXIC CHEMICALS (40 CFR 372): This product contains the following substance(s), (with CAS # and % range) which appear(s) on the List of Toxic Chemicals Hazardous Substance(s)
SECTION 313 - LIST OF TOXIC CHEMICALS (40 CFR 372):
CAS NO Hydrazine 302-01-2 30.0-60.0 TOXIC SUBSTANCES CONTROL ACT (TSCA): The substances in this preparation are included on or exempted from the TSCA 8(b) Inventory (40 CFR 710)FOOD AND DRUG ADMINISTRATION (FDA) Federal Food, Drug and Cosmetic Act: When use situations necessitate compliance with FDA regulations, this product is acceptable under: 21 CFR 173.310 Boiler Water Additives The following limitations apply: Maximum dosage Limitation ZERO PPM as product in the steam Nalco Company 1601 W. Diehl Road -Naperville, Illinois 60563w1198  
This product contains the following substance(s), (with CAS # and % range) which appear(s) on the List of Toxic Chemicals Hazardous Substance(s)                                   CAS NO Hydrazine                                                 302-01-2                         30.0-60.0 TOXIC SUBSTANCES CONTROL ACT (TSCA):
* (630)305-1000 For additional copies of an MSDS visit wvwv.nalco.com and request access.10113 Attachment NOC-AE-14003142 Page 140 of 155 r 4 NALCO SAFETY DATA SHEET PRODUCT ii NALCOR 19.H EMERGENCY TELEPHONE NUMBER(S)(800) 424-9300 (24 Hours) CHEMTREC Steam produced may be used in contact with any food type, defined under 21 CFR 170.3, which includes milk or milk products.NSF NON-FOOD COMPOUNDS REGISTRATION PROGRAM (former USDA List of Proprietary Substances  
The substances in this preparation are included on or exempted from the TSCA 8(b) Inventory (40 CFR 710)
&Non-Food Compounds)  
FOOD AND DRUG ADMINISTRATION (FDA) Federal Food, Drug and Cosmetic Act:
: NSF Registration number for this product is : 062465 This product is acceptable for treating boilers or steam lines where steam produced may contact edible products and/or cooling systems where the treated water may not contact edible products in and around food processing areas FEDERAL WATER POLLUTION CONTROL ACT, CLEAN WATER ACT, 40 CFR 401.15 / formerly Sec. 307,40 CFR 116.4/ formerly Sec. 311 : Substances.listed under this regulation are not intentionally added or expected to be present in this product. Listed components may be present at trace levels.CLEAN AIR ACT, Sec. 112 (Hazardous Air Pollutants, as amended by 40 CFR 63), Sec. 602 (40 CFR 82, Class I and II Ozone Depleting Substances)  
When use situations necessitate compliance with FDA regulations, this product is acceptable under: 21 CFR 173.310 Boiler Water Additives The following limitations apply:
: This product contains the following substances listed in the regulation.
Maximum dosage                               Limitation ZERO PPM                                     as product in the steam Nalco Company 1601 W. Diehl Road - Naperville, Illinois 60563w1198 * (630)305-1000 For additional copies of an MSDS visit wvwv.nalco.com and request access.
Additional components may be unintentionally present at trace, levels.Substance(s)
10113
Citations.Hydrazine Sec. 112:CALIFORNIA PROPOSITION 65: This product contains the following substances which require warnin, 9 under California Proposition  
 
: 65. Additional
Attachment NOC-AE-14003142 Page 140 of 155 SAFETY DATA SHEET PRODUCT                     ii r4      NALCO                                    NALCOR 19.H EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours) CHEMTREC Steam produced may be used in contact with any food type, defined under 21 CFR 170.3, which includes milk or milk products.
NSF NON-FOOD COMPOUNDS REGISTRATION PROGRAM (former USDA List of Proprietary Substances &
Non-Food Compounds) :
NSF Registration number for this product is : 062465 This product is acceptable for treating boilers or steam lines where steam produced may contact edible products and/or cooling systems where the treated water may not contact edible products in and around food processing areas FEDERAL WATER POLLUTION CONTROL ACT, CLEAN WATER ACT, 40 CFR 401.15 / formerly Sec. 307,40 CFR 116.4/ formerly Sec. 311 :
Substances.listed under this regulation are not intentionally added or expected to be present in this product. Listed components may be present at trace levels.
CLEAN AIR ACT, Sec. 112 (Hazardous Air Pollutants, as amended by 40 CFR 63), Sec. 602 (40 CFR 82, Class I and II Ozone Depleting Substances) :
This product contains the following substances listed in the regulation. Additional components may be unintentionally present at trace, levels.
Substance(s)                                     Citations
                      . Hydrazine                                     Sec. 112
:CALIFORNIA PROPOSITION 65:
This product contains the following substances which require warnin,9 under California Proposition 65. Additional
.........
.........
* componentsr may b- h-ffie-f -lypresenteattracetlevels  
* componentsr may b- h-ffie-f -lypresenteattracetlevels   le.ve      . ............                         . ..
.............  
Substance(s)                                 Concentration     EFFECTS
...le.ve Substance(s)
* Hydrazine                                 <60%             Causes Cancer MICHIGAN CRITICAL MATERIALS:
Concentration EFFECTS* Hydrazine  
This product contains the following substances listed in the regulation. Additional components may be unintentionally present at trace levels.
<60% Causes Cancer MICHIGAN CRITICAL MATERIALS:
Hydrazine STATE RIGHT TO KNOW LAWS:
This product contains the following substances listed in the regulation.
The following substances are disclosed for compliance with Stale Right to Know Laws:
Additional components may be unintentionally present at trace levels.Hydrazine STATE RIGHT TO KNOW LAWS: The following substances are disclosed for compliance with Stale Right to Know Laws: Hydrazine 302-01-2 Nalco Company 1601 W. Diehl Road .Naperville, Illinois 60563-1198  
Hydrazine                                       302-01-2 Nalco Company 1601 W. Diehl Road . Naperville, Illinois 60563-1198 * (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.
* (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.11/13 Attachment NOC-AE-14003142 Page 141 of 155 NNALCO SAFETY DATA SHEET PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)(800) 424-9300 (24 Hours) CHEMTREC INTERNATIONAL CHEMICAL CONTROL LAWS: CANADIAN ENVIRONMENTAL PROTECTION ACT (CEPA): The substance(s) in this preparation are included In or exempted from the Domestic Substance List (DSL).AUSTRALIA All substances in this product comply with the National Industrial Chemicals Notification  
11/13
& Assessment Scheme (NICNAS)., .CHINA All substances In this product comply with the Provisions on the Environmental Administration of New Chemical Substances and are listed on or exempt from the Inventory of Existing Chemical Substances China (IECSC).EUROPE The substances in this preparation have been reviewed for compliance with the EINECS or ELINCS inventories.
 
JAPAN All substances in this product comply with the Law Regulating the Manufacture and importation Of Chemical Substances and are listed on the Existing and New Chemical Substances list (ENCS).KOREA All substances in this product comply with the Toxic Chemical Control Law (TCCL) and are listed on the Existing Chemicals List (ECL)PHILIPPINES All substances in this product comply with the Republic Act 6969 (RA 6969) and are listed on the Philippines Inventory 16. OTHER INFORMATION This product material safety data sheet provides health and safety information.
Attachment NOC-AE-14003142 Page 141 of 155 SAFETY DATA SHEET NNALCO                                            PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)
The product Is to be used in applications consistent with our product literature.
(800) 424-9300 (24 Hours) CHEMTREC INTERNATIONAL CHEMICAL CONTROL LAWS:
Individuals handling this product should be informed of the recommended safety precautions and should have access to this information.
CANADIAN ENVIRONMENTAL PROTECTION ACT (CEPA):
For any other uses, exposures should be evaluated so that appropriate handling practices and training programs can be established to insure safe workplace operations.
The substance(s) in this preparation are included In or exempted from the Domestic Substance List (DSL).
Please consult your local sales representative for any further information.
AUSTRALIA All substances in this product comply with the National Industrial Chemicals Notification & Assessment Scheme (NICNAS).,           .
REFERENCES Threshold Limit Values for Chemical Substances and Physical Agents and Biological Exposure Indices, American Conference of Governmental Industrial Hygienists, OH., (Arlel InsightTM CD-ROM Version), Ariel Research Corp., Bethesda, MD.Hazardous Substances Data Bank, National Library of Medicine, Bethesda, Maryland (TOMES CPS'm CD-ROM Version), Micromedex, Inc., Englewood, CO.Nalco Company 1601 W. Diehl Road
CHINA All substances In this product comply with the Provisions on the Environmental Administration of New Chemical Substances and are listed on or exempt from the Inventory of Existing Chemical Substances China (IECSC).
* Naperville, Illinois 60563-1198  
EUROPE The substances in this preparation have been reviewed for compliance with the EINECS or ELINCS inventories.
* (630)305-1000 For additional copies of an MSDS. visit www.nalco.com and request access.12/13 Attachment NOC-AE-14003142 Page 142 of 155 N"NALCO SAFETY DATA SHEET PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)(800) 424-9300 (24 Hours) CHEMTREC IARC Monographs on the Evaluation of the Carcinogenic Risk- of Chemicals to Man, Geneva: World Health Organi.za.tion, Iternaional Agency for Research on.Cancer...........................
JAPAN All substances in this product comply with the Law Regulating the Manufacture and importation Of Chemical Substances and are listed on the Existing and New Chemical Substances list (ENCS).
Integrated Risk Information System, U.S. Environmental Protection Agency, Washington, D.C. (TOMES CPSTM CD-ROM Version), Micromedex, Inc., Englewood, CO.Annual Report on Carcinogens, National Toxicology Program, U.S. Department of Health and Human Services, Public Health Service.Title 29 Code of Federal Regulations, Part 1910, Subpart Z, Toxic and Hazardous Substances, Occupational Safety and Health Administration (OSHA), (Ariel InsightThM CD-ROM Version), Ariel Research Corp., Bethesda, MD.Registry of Toxic Effects of Chemical Substances, National Institute for Occupational Safety and Health, Cincinnati, OH, (TOMES CPSTM CD-ROM Version), Micromedex, Inc., Englewood, CO, AAdel InsightTM (An integrated guide to industrial chemicals covered under major regulatory and advisory programs), North American Module, Western European Module, Chemical Inventories Module and the Generics Module (Ariel Insight T M CD-ROM Version), Ariel Research Corp., Bethesda, MD.The Teratogen Information System, University of Washington, Seattle, WA (TOMES CPSTM CD-ROM Version), Micromedex, Inc., Englewood, CO...Prepared-By-mr -.. ..... ............  
KOREA All substances in this product comply with the Toxic Chemical Control Law (TCCL) and are listed on the Existing Chemicals List (ECL)
....Date issued : 06127/2012 Version Number: 4.2 Nalco Company 1601 W. Diehl Road
PHILIPPINES All substances in this product comply with the Republic Act 6969 (RA 6969) and are listed on the Philippines Inventory
* Naperville, Illinois 60563-1198  
: 16.       OTHER INFORMATION This product material safety data sheet provides health and safety information. The product Is to be used in applications consistent with our product literature. Individuals handling this product should be informed of the recommended safety precautions and should have access to this information. For any other uses, exposures should be evaluated so that appropriate handling practices and training programs can be established to insure safe workplace operations. Please consult your local sales representative for any further information.
.(630)305-1000 For additional copies of an MSDS visit www:nalco.com and request access.13/13 Attachment NOC-AE-14003142 Page 143 of 155 (C'age 2 of 13)_______SAFETY DATA SHEET A4 PRODUCT LCS-60 EMERGENCY TELEPHONE NUMBER(S)(800) 424-300 (24 Hours) CHEMTREC 1: CHIEMICAL PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME: LCS-_0 APPLICATION:
REFERENCES Threshold Limit Values for Chemical Substances and Physical Agents and Biological Exposure Indices, American Conference of Governmental Industrial Hygienists, OH., (Arlel InsightTM CD-ROM Version), Ariel Research Corp.,
WATER TREATMENT COMPANY IDENTIFICATION:
Bethesda, MD.
Nalco Company 161-WT~ieni Roacd Naperville, Illinois 60563-1198 EMERGENCY TELEPHONE NUMBER(S):  
Hazardous Substances Data Bank, National Library of Medicine, Bethesda, Maryland (TOMES CPS'm CD-ROM Version), Micromedex, Inc., Englewood, CO.
(800) 424-9300 (24 Hours) CHEMTREC NFPA 704M/HMIS RATING HEALTH: 2/2 FLAMMABILITY:
Nalco Company 1601 W. Diehl Road
0/0 INSTABILITY:
* Naperville, Illinois 60563-1198 * (630)305-1000 For additional copies of an MSDS. visit www.nalco.com and request access.
010 OTHER:------- O-=-tnsignificant--l-  
12/13
--Slight ---
 
: 12. 1 COMPOSITIONIINFORMATION ON INGREDIENTS Our hazard evaluation has Identified the following chemical substance(s) as hazardous.
Attachment NOC-AE-14003142 Page 142 of 155 SAFETY DATA SHEET N"NALCO                                           PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)
Consult Section 15 for the nature of the hazard(s).
(800) 424-9300 (24 Hours) CHEMTREC IARC Monographs on the Evaluation of the Carcinogenic Risk-of Chemicals to Man, Geneva: World Health Organi.za.tion, Iternaional Agency for Research on.Cancer...........................
Hazardous Substance(s)
Integrated Risk Information System, U.S. Environmental Protection Agency, Washington, D.C. (TOMES CPSTM CD-ROM Version),
CAS NO % (wlw)Sodium Nitrite 7632-00-0 5.0- 10.0 Sodium Tetraborate 1330-43-4 1.0 -5,0....... .. ....3 .! z A 0 -" i ..... ..... .. ..........  
Micromedex, Inc., Englewood, CO.
.. ...........  
Annual Report on Carcinogens, National Toxicology Program, U.S. Department of Health and Human Services, Public Health Service.
...........
Title 29 Code of Federal Regulations, Part 1910, Subpart Z, Toxic and Hazardous Substances, Occupational Safety and Health Administration (OSHA), (Ariel InsightThM CD-ROM Version), Ariel Research Corp., Bethesda, MD.
.... ..........  
Registry of Toxic Effects of Chemical Substances, National Institute for Occupational Safety and Health, Cincinnati, OH, (TOMES CPSTM CD-ROM Version), Micromedex, Inc., Englewood, CO, AAdel InsightTM (An integrated guide to industrial chemicals covered under major regulatory and advisory programs),
.... ... ...13. 1HAZ-ARDS IDENTIFICATION
North American Module, Western European Module, Chemical Inventories Module and the Generics Module (Ariel Insight TM CD-ROM Version), Ariel Research Corp., Bethesda, MD.
**EMERGENCY OVERVIEW-DANGER Toxic if swallowed, Contains sodium nitrite. Substances In the product can lead to the formation of methemoglobin.
The Teratogen Information System, University of Washington, Seattle, WA (TOMES CPSTM CD-ROM Version),
Micromedex, Inc., Englewood, CO.
. Prepared-By-
  .              -Product'Safety&#xfd;-De*  r--*tit. -
mr         ..             .     .         ... ............ . . ..
Date issued : 06127/2012 Version Number: 4.2 Nalco Company 1601 W. Diehl Road
* Naperville, Illinois 60563-1198 .(630)305-1000 For additional copies of an MSDS visit www:nalco.com and request access.
13/13
 
Attachment NOC-AE-14003142 Page 143 of 155 (C'age 2 of   13)
DATA SHEET A4
_______SAFETY PRODUCT LCS-60 EMERGENCY TELEPHONE NUMBER(S)
(800) 424-300 (24 Hours) CHEMTREC 1:         CHIEMICAL PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME:                                       LCS-_0 APPLICATION:                                         WATER TREATMENT COMPANY IDENTIFICATION:                             Nalco Company 161-WT~ieni Roacd Naperville, Illinois 60563-1198 EMERGENCY TELEPHONE NUMBER(S):                       (800) 424-9300 (24 Hours)           CHEMTREC NFPA 704M/HMIS RATING HEALTH:         2/2       FLAMMABILITY:       0/0       INSTABILITY:           010         OTHER:
-------     O-=-tnsignificant--l--- Slight ---2--Moderate--3-=-Righ--4-=-Extreme-'*-Chronic-Health-Hazard
: 12.       1 COMPOSITIONIINFORMATION ON INGREDIENTS Our hazard evaluation has Identified the following chemical substance(s) as hazardous. Consult Section 15 for the nature of the hazard(s).
Hazardous Substance(s)                                         CAS NO                       % (wlw)
Sodium Nitrite                                                                       7632-00-0                     5.0- 10.0 Sodium Tetraborate
                                  ....... 0..-"
                                              . ...i 3. ! zA..... . . . .. . . . . . ... .......... . .......... ..... . . . . ..........
1330-43-4                      1.0 - 5,0
: 13.       1HAZ-ARDS IDENTIFICATION
                                                          **EMERGENCY OVERVIEW-DANGER Toxic if swallowed, Contains sodium nitrite. Substances In the product can lead to the formation of methemoglobin.
Unborn children are particularly sensitive to methemoglobinemia.
Unborn children are particularly sensitive to methemoglobinemia.
Do not get in eyes, on skin, on clothing.
Do not get in eyes, on skin, on clothing. Do not take Internally. Use with adequate ventilation. In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. After contact with skin, wash immediately with plenty of water.
Do not take Internally.
Wear suitable protective clothing.
Use with adequate ventilation.
May evolve oxides of nitrogen (NOx) under fire conditions. If product is allowed to dry, the sodium nitrite is an oxidizing agent and can initiate the combustion of other materials, Not flammable or combustible.
In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. After contact with skin, wash immediately with plenty of water.Wear suitable protective clothing.May evolve oxides of nitrogen (NOx) under fire conditions.
If product is allowed to dry, the sodium nitrite is an oxidizing agent and can initiate the combustion of other materials, Not flammable or combustible.
P RIMARY'ROUTESOFEXPOSUR.:
P RIMARY'ROUTESOFEXPOSUR.:
Eye, Skin HUMAN HEALTH HAZARDS -ACUTE: EYE CONTACT: Can cause mild to moderate irritation.
Eye, Skin HUMAN HEALTH HAZARDS -ACUTE:
Nalco Company 1601 W. Diehl Road' Naperville, Illinois 60563-1198  
EYE CONTACT:
* (630)305-1000 For additional copies of an MSDS visit www.nalcocom and request access.1/10 9 Attachment NOC-AE-14003142 Page 144 of 155 i~age 3 :! 13)____ ___ SAFETY DATA SHEET -_PRODUCT~NALCO LS6 EMERGENCY TELEPHONE NUMBER(S)(BO)424-9300 (24 Hours) CHEMTREC SKIN CONTACT: May cause Irritation with prolonged contact INGESTION:
Can cause mild to moderate irritation.
Not a likely route of exposure.
Nalco Company 1601 W. Diehl Road' Naperville, Illinois 60563-1198 * (630)305-1000 For additional copies of an MSDS visit www.nalcocom and request access.
Large exposures may be fatal. Ingestion of sodium nitrile can cause methemoglobinemia which can lead to cyanosis and possible death. Pregnant women and their fetuses are parIcuray methemoglobinemia.
1/10 9
 
Attachment NOC-AE-14003142 Page 144 of 155 i~age 3 :! 13)
____   ___                                       SAFETY DATA SHEET                                                       -_
PRODUCT
                    ~NALCO                                       LS6 EMERGENCY TELEPHONE NUMBER(S)
(BO)424-9300 (24 Hours) CHEMTREC SKIN CONTACT:
May cause Irritation with prolonged contact INGESTION:
Not a likely route of exposure. Large exposures may be fatal. Ingestion of sodium nitrile can cause methemoglobinemia which can lead to cyanosis and possible death. Pregnant women and their fetuses are parIcurayysetTv-e-ft*o-the e*rectsdf methemoglobinemia.
INHALATION:
INHALATION:
Not a likely route of exposure.
Not a likely route of exposure. Aerosols or product mist may irritate the upper respiratory tract.
Aerosols or product mist may irritate the upper respiratory tract.AGGRAVATION OFEXISTING CONDITIONS:
AGGRAVATION OFEXISTING CONDITIONS:
Sodium Nitrite. Pregnant women are particularly sensitive to methernoglobinemia.
Sodium Nitrite. Pregnant women are particularly sensitive to methernoglobinemia.
HUMAN HEALTH HAZARDS -CHRONIC.: Repeated ingestion of small amounts of sodium nitrite causes drops in blood pressure, rapid pulse, headaches and visual disturbances.
HUMAN HEALTH HAZARDS - CHRONIC.:
It may also react with organic amines In the body to form carcinogenic nitrosamines.
Repeated ingestion of small amounts of sodium nitrite causes drops in blood pressure, rapid pulse, headaches and visual disturbances. It may also react with organic amines In the body to form carcinogenic nitrosamines.
: 14. 1 FIRST AID MEASURES SKIN CONTACT: Immediately flush with plenty of water for at least 15 minutes. If symptoms develop, seek medical advice.INGESTION:
: 14.       1 FIRST AID MEASURES SKIN CONTACT:
Get Immediate medical attention.
Immediately flush with plenty of water for at least 15 minutes. If symptoms develop, seek medical advice.
Do not Induce vomiting without medical advice. If conscious, washout mouth and-give--wat-er-to.drink;.......  
INGESTION:
.... ..INHALATION:
Get Immediate medical attention. Do not Induce vomiting without medical advice. If conscious, washout mouth and
Remove to fresh air, treat symptomatically.
                                                                                                              -give--wat-er-to.drink;....... .... . .
Get medical attention.
INHALATION:
Remove to fresh air, treat symptomatically. Get medical attention.
NOTE TO PHYSICIAN:
NOTE TO PHYSICIAN:
Based on the individual reactions of the patient, the physician's judgement should be used to control symptoms and clinical condition.
Based on the individual reactions of the patient, the physician's judgement should be used to control symptoms and clinical condition. Measures against circulatory shock, respiratory depression and convulsions may be needed.
Measures against circulatory shock, respiratory depression and convulsions may be needed.15. 1 FIRE FIGHTING MEASURES FLASH POINT: None EXTINGUISHING MEDIA : Not expected to burn. Use extinguishing media appropriate for surrounding fire.FIRE AND EXPLOSION HAZARD : May evolve oxides of nitrogen (NOx) under fire conditions.
: 15.       1FIRE FIGHTING MEASURES FLASH POINT:                               None EXTINGUISHING MEDIA :
If product is allowed todry, the sodium nitrite is an oxidizing agent and can initiate the combustion of other materials.
Not expected to burn. Use extinguishing media appropriate for surrounding fire.
Not flammable or combustible.
FIRE AND EXPLOSION HAZARD :
SPECIAL PROTECTIVE EQUIPMENT FOR FIRE FIGHTING: In case of fire, wear a full face positive-pressure self contained breathing apparatus and protective suit.Nalco Company 1601 W. Dihl Road
May evolve oxides of nitrogen (NOx) under fire conditions. Ifproduct is allowed todry, the sodium nitrite is an oxidizing agent and can initiate the combustion of other materials. Not flammable or combustible.
* Naperville.
SPECIAL PROTECTIVE EQUIPMENT FOR FIRE FIGHTING:
Illinois 60563-1198  
In case of fire, wear a full face positive-pressure self contained breathing apparatus and protective suit.
-(630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.2110 Attachment NOC-AE-14003142 Page 145 of 155 (Page 4 of 13)SAFETY DATA SHEET.N04 PRODUCT*- LCS-60 EMERGENCY TELEPHONE NUMBER(S)(800)424-9300 (24 Hours) CHEMTREC 6. 'ACCIDENTAL RELEASE MEASURES PERSONAL PRECAUTIONS:
Nalco Company 1601 W. Dihl Road
Restrict access to area as appropriate until clean-up operations are complete.
* Naperville. Illinois 60563-1198 - (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.
Use personal protective equipment recommended in Section 8 (Exposure Controls/Personal Protection).
2110
Stop or reduce any leaks If it is safe to do so.Keep people away from and upwind of spill/leak.
 
Ventilate spill area if possible.
Attachment NOC-AE-14003142 Page 145 of 155 (Page 4 of 13)
Ensure clean-up Is conducted by trained personnel only. Do not touchIoLfediateidaLtJaiwemnegency-equipmenL(for.fires~spillsr.eaksretc.)-readily available, Notify appropriate government, occupational health and safety and environmental authorities.
              .N04                                                SAFETY DATA SHEET PRODUCT
METHODS FOR CLEANING UP: SMALL SPILLS: Soak up spill with absorbent material.
                                                                *- LCS-60
Place residues in a suitable, covered, property labeled-----container.-Wash-afected-aa.-LARGE-SP-LLS:--Contain liquid-using absorbent-material'-by-digginig~tenches~orby  
* EMERGENCY TELEPHONE NUMBER(S)
-diking. Reclaim into recovery or salvage drums or tank truck for proper disposal.
(800)424-9300 (24 Hours) CHEMTREC
Wash site of spillage thoroughly with water. Contact an aoproved waste hauler fordisposal of contaminated recovered material.
: 6.         'ACCIDENTAL           RELEASE MEASURES PERSONAL PRECAUTIONS:
D.ipose of material in compliance with regulations Indicated in Section 13 (Disposal Considerations).
Restrict access to area as appropriate until clean-up operations are complete. Use personal protective equipment recommended in Section 8 (Exposure Controls/Personal Protection). Stop or reduce any leaks Ifit is safe to do so.
Do not allow product to evaporate to dryness.ENVIRONMENTAL PRECAUTIONS:
Keep people away from and upwind of spill/leak. Ventilate spill area if possible. Ensure clean-up Is conducted by trained personnel only. Do not touchIoLfediateidaLtJaiwemnegency-equipmenL(for.fires~spillsr.eaksretc.)-readily available, Notify appropriate government, occupational health and safety and environmental authorities.
METHODS FOR CLEANING UP:
SMALL SPILLS: Soak up spill with absorbent material. Place residues in a suitable, covered, property labeled
      ----- container.-Wash-afected-aa.-LARGE-SP-LLS:--Contain liquid-using absorbent-material'-by-digginig~tenches~orby                 -
diking. Reclaim into recovery or salvage drums or tank truck for proper disposal. Wash site of spillage thoroughly with water. Contact an aoproved waste hauler fordisposal of contaminated recovered material. D.ipose of material in compliance with regulations Indicated in Section 13 (Disposal Considerations). Do not allow product to evaporate to dryness.
ENVIRONMENTAL PRECAUTIONS:
Prevent material from entering sewers or waterways., Spilled product may pose a risk to the aquatic ecosystem if released., If drains, streams, sil or sewers become contaminated, notify local authority.
Prevent material from entering sewers or waterways., Spilled product may pose a risk to the aquatic ecosystem if released., If drains, streams, sil or sewers become contaminated, notify local authority.
: 17. HANDLING AND STORAGE HANDLING: Do not take internally.
: 17.           HANDLING AND STORAGE HANDLING:
Use with adequate ventilation.
Do not take internally. Use with adequate ventilation. Do not breathe vapors/gases/dust. Do not get in eyes, on skin, on.clothing, Have emergency equmeT (for fires, spills eaks. etc.) readily av*giable.,        sur4alLcgnjes ar..
Do not breathe vapors/gases/dust.
STORAGE CONDITIONS:
Do not get in eyes, on skin, on.clothing, Have emergency equmeT (for fires, spills eaks. etc.) readily sur4alLcgnjes ar..STORAGE CONDITIONS:
Store In suitable labeled containers. Store the containers tightly closed. Store away from organic chemicals and other oxidizable materials, reducing agents, acids and alkalis.
Store In suitable labeled containers.
SUITABLE CONSTRUCTION MATERIAL:
Store the containers tightly closed. Store away from organic chemicals and other oxidizable materials, reducing agents, acids and alkalis.SUITABLE CONSTRUCTION MATERIAL: Shipping and long term storage compatibility with construction materials can vary; we therefore recommend that compatibility is tested prior to use.18. EXPOSURE CONTROLSIPERSONAL PROTECTION OCCUPATIONAL EXPOSURE LIMITS: Exposure guidelines have not been established for this product. Available exposure limits for the substance(s) are shown below.Substance(s)
Shipping and long term storage compatibility with construction materials can vary; we therefore recommend that compatibility is tested prior to use.
Category; ppm mg/m3 Non-Standard Unit Borates, Tetra, Sodium Salts -Anhydrous (Inhalable ACGIHITWA 2 fraction.)
: 18.           EXPOSURE CONTROLSIPERSONAL PROTECTION OCCUPATIONAL EXPOSURE LIMITS:
ACGIH/STEL 6 Nalco Company 1601 W. Diehl. Road
Exposure guidelines have not been established for this product. Available exposure limits for the substance(s) are shown below.
* Naperville.
Substance(s)                                           Category;                     ppm         mg/m3     Non-Standard Unit Borates, Tetra, Sodium Salts - Anhydrous (Inhalable   ACGIHITWA                                     2 fraction.)
Illinois 60563-1198  
ACGIH/STEL                                     6 Nalco Company 1601 W. Diehl. Road
* (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access: 3/10 Attachment NOC-AE-14003142 Page 146 of 155 (Page 5 of 13)..NALCO SAFETY DATA SHEET!PRODUCT.iLCs-60 EMERGENCY TELEPHONE NUMBER(S)(800) 424-9300 (24 Hours) CHEMTREC ENGINEERING MEASURES: General ventilation Is recommended.-RESPIRATORY PROTECTION:
* Naperville. Illinois 60563-1198 * (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access:
Resplratorv protection is not normally needed. Where o eithis~seio_
3/10
or when significant mists, vapors, aerosols, or dusts are generated, an approved air purifying respirator equipped with suitablefilter cartridges is recommended.
 
Consult the respirator  
Attachment NOC-AE-14003142 Page 146 of 155 (Page 5   of   13)
/ cartridge manufacturer data to verify the suitability of specific devices. In event of emergency or planned entry into unknown concentrations a positive pressure, full-facepiece SCBA should be used. If respiratory protection Is required, institute a complete.
SAFETY DATA SHEET
respiratory protection program including selection, fit testing, training, maintenance and inspection.
                                                                                      !PRODUCT.
                    .. NALCO                                                            iLCs-60 EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours) CHEMTREC ENGINEERING MEASURES:
General ventilation Is recommended.
              -RESPIRATORY PROTECTION:
Resplratorv protection is not normally needed. Where o                                               eithis~seio_
or when significant mists, vapors, aerosols, or dusts are generated, an approved air purifying respirator equipped with suitablefilter cartridges is recommended. Consult the respirator / cartridge manufacturer data to verify the suitability of specific devices. In event of emergency or planned entry into unknown concentrations a positive pressure, full-facepiece SCBA should be used. If respiratory protection Is required, institute a complete. respiratory protection program including selection, fit testing, training, maintenance and inspection.
HAND PROTECTION:
HAND PROTECTION:
When handling this product, the use of chemical gloves Is recommended.
When handling this product, the use of chemical gloves Is recommended. The choice of work glove depends on work conditions and what chemicals are handled. Please contact the PPE manufacturer for advice on what type of glove material may be suitable. Gloves should be replaced Immediately if signs of degradation are observed.
The choice of work glove depends on work conditions and what chemicals are handled. Please contact the PPE manufacturer for advice on what type of glove material may be suitable.
SKIN PROTECTION:
Gloves should be replaced Immediately if signs of degradation are observed.SKIN PROTECTION:
Wear standard protective clothing.
Wear standard protective clothing.EYE PROTECTION:
EYE PROTECTION:
Wear chemical splash goggles.HYGIENE RECOMMENDATIONS:
Wear chemical splash goggles.
----- .U -se-g-od-work-and-persoral-h.ygiene-prat-ces-to-avod-exposure--Keepr-rreye--ashfour-ain-aaitableKeep
HYGIENE RECOMMENDATIONS:
.............
-----           .U                                                                                                                           ............. -se-g-od-work-and-p
conta minatod-clothing:before-reuse.-Always-wash thoroughly-aafter-handling-chemicals-When-handling.this-product never.eatj drinkeor smoke.I 9. I PHYSICAL AND CHEMICAL PROPERTIES PHYSICAL STATE APPEARANCE ODOR SPECIFIC GRAVITY DENSITY SOLUBILITY IN WATER pH (100 %)VAPOR PRESSURE VOC CONTENT Liquid Clear Light yellow None 1.076. @ 77 "F / 25 "C 8.96 lb/gal Complete 8-9 Same as water 0.0 % EPA Method 24___Note:Ihese-chysicaboro~ertiesArelyicaLvalues-for-hisrcwductand-are-sublcieo-tchanne.
                *safety-showr-vai~lable,-If:*J!h**qj&#xfd;cotminatedemyeqrgndtruhyas:haetdaa-Lner conta minatod-clothing:before-reuse.-Always-wash thoroughly-aafter-handling-chemicals-When-handling.this-product never.eatj drinkeor smoke.
Nalco Company 1601 W. Diehl Road -Naperville, Illinois 60563-1198  
I 9.         I PHYSICAL AND CHEMICAL PROPERTIES PHYSICAL STATE                         Liquid APPEARANCE                             Clear Light yellow ODOR                                    None SPECIFIC GRAVITY                                        1.076. @ 77 "F / 25 "C DENSITY                                                8.96 lb/gal SOLUBILITY IN WATER                                    Complete pH (100 %)                                              8-9 VAPOR PRESSURE                                          Same as water VOC CONTENT                                            0.0 % EPA Method 24
* (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.4/10 Attachment NOC-AE-14003142 Page 147 of 155 (2g of 13)7NALCO SAFETY DATA SHEET PRODUCT LCS-60 I II i i I II ', EMERGENCY TELEPHONE NUMBER(S)(800) 424-9300 (24 Hours) CHIEMTREC 110. I STABILITY AND REACTIVITY I STABILITY:
___Note:Ihese-chysicaboro~ertiesArelyicaLvalues-for-hisrcwductand-are-sublcieo-tchanne.
Nalco Company 1601 W. Diehl Road - Naperville, Illinois 60563-1198 * (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.
4/10
 
Attachment NOC-AE-14003142 Page 147 of 155 (2g of 13)
SAFETY DATA SHEET                               I         II i i I II   ',
PRODUCT 7NALCO                                            LCS-60 EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours) CHIEMTREC 110.       I STABILITY AND REACTIVITY                                                                                           I STABILITY:
Stable under normal conditions.
Stable under normal conditions.
HAZARDOUS POLYMERIZATION:
HAZARDOUS POLYMERIZATION:
Hazardous polymerization will not occur.CONDITIONS TO AVOID: Freezing temperatures.
Hazardous polymerization will not occur.
MATERIALS-TO-AVOID4 Contact with reducing agents (e.g. hydrazine, sulfites, sulfide, aluminum or magnesium dust) may generate heat, fires, explosions and toxic vapors. Do not mix with amines. Sodium nitrite can react with certain amines to produce N-nitrosamines, many of which are cancer-causing agents to laboratory animals. Contact with strong acids (e.g.sulfuric, phosphoric, nitric, hydrochloric, chromic, sulfonic) may generate heat, splattering or boiling and toxic vapors.HAZARDOUS DECOMPOSITION PRODUCTS: Under fire conditions:
CONDITIONS TO AVOID:
Oxides of nitrogen, Oxides of sodium 11. 1 TOXICOLOGICAL INFORMATION No toxicity studies have been conducted on this product.SENSITIZATION:
Freezing temperatures.
MATERIALS-TO-AVOID4 Contact with reducing agents (e.g. hydrazine, sulfites, sulfide, aluminum or magnesium dust) may generate heat, fires, explosions and toxic vapors. Do not mix with amines. Sodium nitrite can react with certain amines to produce N-nitrosamines, many of which are cancer-causing agents to laboratory animals. Contact with strong acids (e.g.
sulfuric, phosphoric, nitric, hydrochloric, chromic, sulfonic) may generate heat, splattering or boiling and toxic vapors.
HAZARDOUS DECOMPOSITION PRODUCTS:
Under fire conditions:             Oxides of nitrogen, Oxides of sodium
: 11.     1 TOXICOLOGICAL INFORMATION No toxicity studies have been conducted on this product.
SENSITIZATION:
This product is not expected to be a sensitizer.
This product is not expected to be a sensitizer.
-.-CA -CR RCINO'GENI C t'- C : None of the substances in this product are listed as carcinogens by the International Agency for Research on Cancer (IARC), the National Toxicology Program (NTP) or the American Conference of Governmental Industrial Hygienists'(ACGIH).TERATOGENICITY AND EMBRYOTOXICITY:
-.- CA     -CRRCINO'GENI C t'- : C None of the substances in this product are listed as carcinogens by the International Agency for Research on Cancer (IARC), the National Toxicology Program (NTP) or the American Conference of Governmental Industrial Hygienists' (ACGIH).
Experimental animal studies with sodium nitrite have shown reproductive effects in the offspring of treated parents.These effects are not transmissible.
TERATOGENICITY AND EMBRYOTOXICITY:
112. I ECOLOGICAL INFORMATION I ECOTOXICOLOGICAL EFFECTS: The following results are for the product.ACUTE FISH RESULTS: s1cies Exposure LC50 Test Descriptor Rainbow Trout 96 hrs 20 m ACUTE INVERTEBRATE RESULTS: Species Exposure LC50 I EC50 I Test Descriptor Nalco Company 1601 W. Diehl Road -Naperville, Illinois 60563-1198  
Experimental animal studies with sodium nitrite have shown reproductive effects in the offspring of treated parents.
-(630)305-1000 For additional copies. of an MSDS visit www.nalco.com and request access.5/10 Attachment NOC-AE-14003142 Page 148 of 155 (page 7 of 13)NANALCO EMERGENCY lELEPHONE NUMBER(S)(800) 424-9300 (24 Hours) CHEMTREC Daphnia magna 48 hrs 340m 2t0m mI MOBILITY: The environmental fate was estimated using a level III fugacity model embedded in the EPI (estimation program interface)
These effects are not transmissible.
Suite TM, provided by the US EPA. The model assumes a steady state condition between the total input and output. The level III model does not require equilibrium between the defined media. The Information provided is intended to give the user a general estimate of the environmental fate of this product under the defined conditions of the models.If released into the environment this material is expected to distribute to the air. water and soillsediment in the approximate respective percentages;
112.       I ECOLOGICAL INFORMATION                                                                                             I ECOTOXICOLOGICAL EFFECTS:
<5% 30,-50% 50 -70%_The portion in water is expected to be soluble or dispersible.
The following results are for the product.
ACUTE FISH RESULTS:
s1cies                             Exposure         LC50                 Test Descriptor Rainbow Trout                       96 hrs           20 m ACUTE INVERTEBRATE RESULTS:
Species                             Exposure         LC50           I EC50         I Test Descriptor Nalco Company 1601 W. Diehl Road - Naperville, Illinois 60563-1198 - (630)305-1000 For additional copies. of an MSDS visit www.nalco.com and request access.
5/10
 
Attachment NOC-AE-14003142 Page 148 of 155 (page 7         of 13)
NANALCO EMERGENCY lELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours) CHEMTREC Daphnia magna                     48 hrs           340m             2t0m mI MOBILITY:
The environmental fate was estimated using a level III fugacity model embedded in the EPI (estimation program interface) Suite TM, provided by the US EPA. The model assumes a steady state condition between the total input and output. The level III model does not require equilibrium between the defined media. The Information provided is intended to give the user a general estimate of the environmental fate of this product under the defined conditions of the models.
If released into the environment this material is expected to distribute to the air. water and soillsediment in the approximate respective percentages;
                                      <5%                   30,-50%                 50 -70%_
The portion in water is expected to be soluble or dispersible.
BIOACCUMULATION POTENTIAL This preparation or materal Is not expected to bloaccumulate.
BIOACCUMULATION POTENTIAL This preparation or materal Is not expected to bloaccumulate.
If released Into the environment, see CERCLA/SUPERFUND in Section 15.13. 1 DISPOSAL CONSIDERATIONS Act (RCRA) 40 CFR 261, since it does not have the characteristics of Subpart C, nor is it listed under Subpart 0..............
If released Into the environment, see CERCLA/SUPERFUND in Section 15.
A"-a -of-sb5]Fcf-1-o-TT:!--aElg~a 6nh nsl tate-o r-lct rgu toa ..................
: 13.     1DISPOSAL CONSIDERATIONS
handling, treatment or disposal requirements.
          -ILthis-product-become-sa~wate*-Lis-not-a`*azardous-wasta-as~delined-by-the.Resource*Conservation-and.Recovery-Act (RCRA) 40 CFR 261, since it does not have the characteristics of Subpart C, nor is it listed under Subpart 0.
For disposal, contact a properly licensed waste treatment, storage, disposal or recycling facility.114. 1 TRANSPORT INFORMATION The information in this section is for reference only and should not take the place of a shipping paper (bill of lading)specific to an order. Please note that the proper Shipping Name / Hazard Class may vary by packaging, properties.
  ............. A"-a non-ha-zarddlis-*w~ste-*jtT- -of-sb5]Fcf-1-o-TT:!--aElg~a 6nh     nsl   tate-o r-lct rgu       *
and mode of transportation.
* toa ..................
Typical Proper Shipping Names for this product areas follows.The presence of an RO component (Reportable Quantity for U.S. EPA and DOT) in this product causes'it lobe regulated vAth an additional description of RO for road, or as a clars 9 for road and air, ONLY when the net weight in the package exceeds the calculated RO for the product.LAND TRANSPORT:
handling, treatment or disposal requirements. For disposal, contact a properly licensed waste treatment, storage, disposal or recycling facility.
Proper Shipping Name: ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S.Technical Name(s): SODIUM NITRITE UN!ID No: UN 3082 Hazard Class -Primary: 9 Packing Group: III Nalco Company 1601 W. Diehl Road
114.     1TRANSPORT INFORMATION The information in this section is for reference only and should not take the place of a shipping paper (bill of lading) specific to an order. Please note that the proper Shipping Name / Hazard Class may vary by packaging, properties.
* Naperville, Illinois 60563-1198  
and mode of transportation. Typical Proper Shipping Names for this product areas follows.
* (630)305-1000 For additional copies of an MSOS visit www.nalcocom and request access.6110 Attachment NOC-AE-14003142 Page 149 of 155 (Page 8 of 13)~NALCO SAFETY DATA SHEET PRODUCT LCS-60 , EMERGENCY TELEPHONE NUMBER(S)(800) 424-9300 (24 Hours) CHIEMTREC Flash Point: .......Reportable Quantity (per package): RQ Component:
The presence of an RO component (Reportable Quantity for U.S. EPA and DOT) in this product causes'it lobe regulated vAth an additional description of RO for road, or as a clars 9 for road and air, ONLY when the net weight in the package exceeds the calculated RO for the product.
N6ne .......1,050 lbs SODIUM NITRITE AIR TRANSPORT (ICAO/IATA):
LAND TRANSPORT:
The presence of an RQ component (Reportable Quantity for U.S. EPA and DOT) in this product causes it to be regulated with an additional description of RO for road, or as a class 9 for road and air, ONLY when the net weight in--the-pockag-xceeds-the-cafcuated'RQ-foth-ro-dar  
Proper Shipping Name:                         ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S.
-Proper Shipping Name: ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S.Technical Name(s): SODIUM NITRITE UNJID No: UN 3082 Hazard Class -Primary: 9 Packing Group: III Reportable Quantity (per package):
Technical Name(s):                             SODIUM NITRITE UN!ID No:                                       UN 3082 Hazard Class - Primary:                       9 Packing Group:                                 III Nalco Company 1601 W. Diehl Road
1,050 lbs RO Component:
* Naperville, Illinois 60563-1198 * (630)305-1000 For additional copies of an MSOS visit www.nalcocom and request access.
SODIUM NITRITE MAR1 NE-TTRSORPORT7IMY G'IMO) : Proper Shipping Name: _PRODUCT IS NOT REGULATED DURING PO-RTATIUON 115S. I REGULATORY INFORMATION I I This section contains additional information that may have relevance to regulatory compliance.
6110
The information in this... m-piane-for hazard assessment.
 
Nalco accepts no liability for the use of this information.
Attachment NOC-AE-14003142 Page 149 of 155 (Page 8 of   13)
NATIONAL REGULATIONS, USA: OSHA HAZARD COMMUNICATION RULE, 29 CFR 1910.1200:
SAFETY DATA SHEET PRODUCT
-----ased-on-our-hazard-evaluat~onTthe-follovving-substance(s)-irrt his prodact-is/are-hazardowsand-thr-mason(s)l s/are-shown below.Sodium Nitrite: Target Organ Effect -Kidney, Target OrganEffect  
                      ~NALCO                                        LCS-60                     ,
-Nervous system, Target Organ Effect -Blood Sodium Tetraborate:
EMERGENCY TELEPHONE NUMBER(S)
Exposure Limit CERCLA/SUPERFUND, 40 CFR 302: This product contains the following Reportable Quantity (RO) Substance.
(800) 424-9300 (24 Hours) CHIEMTREC Flash Point:.......                             N6ne .......
Also listed is the RO for the product. If a reportable quantity of product is released, it requires notification to the NATIONAL RESPONSE CENTER, WASHINGTON, D.C. (1-800-424-8802).
Reportable Quantity (per package):              1,050 lbs RQ Component:                                    SODIUM NITRITE AIR TRANSPORT (ICAO/IATA):
RO Substance Sodium Nitrite RQ 1,050 Ibs Nalco Company 1601 W. DiehlI Road- Naperville.
The presence of an RQ component (Reportable Quantity for U.S. EPA and DOT) in this product causes it to be regulated with an additional description of RO for road, or as a class 9 for road and air, ONLY when the net weight in
Illinois 60563-1198  
        - -the-pockag-xceeds-the-cafcuated'RQ-foth-ro-dar                     -
-(630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.7/10 Attachment NOC-AE-14003142 Page 150 of 155 (Page 9 of 13).*NALCO SAFETY DATA SHEET PRODUCT LCS-60 EMERGENCY TELEPHONE NUMBER(S)(800)424-9300(24 Hours) CHEMTREC SARA/SUPERFUND AMENDMENTS AND REAUTHORIZATION ACT OF 1986 (TITLE III) -SECTIONS 302, 311, 312, AND 313: SECTION 302 -EXTREMELY HAZARDOUS SUBSTANCES (40 CFR 355): This product does not contain substances listed in Appendix A and B as an Extremely Hazardous Substance.
Proper Shipping Name:                           ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S.
SECTIONS 311 AND 312 -MATERIAL SAFETY DATA SHEET REQUIREMENTS (40 CFR 370): Our hazar -e-5---t-0-51ion-nas found this product to be hazardous.
Technical Name(s):                               SODIUM NITRITE UNJID No:                                       UN 3082 Hazard Class - Primary:                         9 Packing Group:                                   III Reportable Quantity (per package):               1,050 lbs RO Component:                                   SODIUM NITRITE MAR1 NE-TTRSORPORT7IMY           G'IMO) :
Theproduct should be reported under the following indicated EPA hazard categories:
Proper Shipping Name: _PRODUCT                               IS NOT REGULATED DURING
X Immediate (Acute) Health Hazard flDrhvp~d fChronink Fire Hazard Sudden Release of Pressure Hazard Reactive Hazard Under SARA 311 and 312, the EPA has established threshold quantities for the reporting of hazardous chemicals.
_________________--TRAN*                                        PO-RTATIUON 115S.     I REGULATORY INFORMATION                                                                                     I I
This section contains additional information that may have relevance to regulatory compliance. The information in this
            . ..m-piane-for hazard assessment. Nalco accepts no liability for the use of this information.
NATIONAL REGULATIONS, USA:
OSHA HAZARD COMMUNICATION RULE, 29 CFR 1910.1200:
      -----   ased-on-our-hazard-evaluat~onTthe-follovving-substance(s)-irrt his prodact-is/are-hazardowsand-thr-mason(s)l s/are-shown below.
Sodium Nitrite: Target Organ Effect - Kidney, Target OrganEffect - Nervous system, Target Organ Effect - Blood Sodium Tetraborate: Exposure Limit CERCLA/SUPERFUND, 40 CFR 302:
This product contains the following Reportable Quantity (RO) Substance. Also listed is the RO for the product. If a reportable quantity of product is released, it requires notification to the NATIONAL RESPONSE CENTER, WASHINGTON, D.C. (1-800-424-8802).
RO Substance                                                   RQ Sodium Nitrite                                                 1,050 Ibs Nalco Company 1601 W. DiehlI Road- Naperville. Illinois 60563-1198 - (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.
7/10
 
Attachment NOC-AE-14003142 Page 150 of 155 (Page 9 of 13)
SAFETY DATA SHEET
                .*NALCO                                             PRODUCT LCS-60 EMERGENCY TELEPHONE NUMBER(S)
(800)424-9300(24 Hours) CHEMTREC SARA/SUPERFUND AMENDMENTS AND REAUTHORIZATION ACT OF 1986 (TITLE III) - SECTIONS 302, 311, 312, AND 313:
SECTION 302 - EXTREMELY HAZARDOUS SUBSTANCES (40 CFR 355):
This product does not contain substances listed in Appendix A and B as an Extremely Hazardous Substance.
SECTIONS 311 AND 312 - MATERIAL SAFETY DATA SHEET REQUIREMENTS (40 CFR 370):
Our hazar-e-5---t-0-51ion- nas found this product to be hazardous. Theproduct should be reported under the following indicated EPA hazard categories:
X                   Immediate (Acute) Health Hazard flDrhvp~d fChronink H*.*hh H*-zird Fire Hazard Sudden Release of Pressure Hazard Reactive Hazard Under SARA 311 and 312, the EPA has established threshold quantities for the reporting of hazardous chemicals.
The current thresholds are: 500 pounds or the threshold planning quantity (TPQ), whichever is lower, for extremely hazardous substances and 10,000 pounds for all other hazardous chemicals.
The current thresholds are: 500 pounds or the threshold planning quantity (TPQ), whichever is lower, for extremely hazardous substances and 10,000 pounds for all other hazardous chemicals.
SECTION 313 -LIST OF TOXIC CHEMICALS (40 CFR 372): This product contains the following substance(s), (with CAS # and % range) which appear(s) on the List of Toxic Chemicals_'1 "-'M ,.f-Nt. ____________-___-
SECTION 313 - LIST OF TOXIC CHEMICALS (40 CFR 372):
Sodium Nitdte 7632-00-0 5.0-10.0"TOXIC-SUBSTANCES CONTROLA-,CT-(TSCA)
This product contains the following substance(s), (with CAS # and % range) which appear(s) on the List of Toxic Chemicals
_3 ....The substances in this preparation are included on or exempted from the TSCA 8(b) Inventory (40 CFR 710)FEDERAL WATER POLLUTION CONTROL ACT, CLEAN WATER ACT. 40 CFRA401.15  
_'1"-'M                                                   ,.f-Nt.                       ____________-___-
/ formerly Sec. 307.40 CFR 116.4/ formerly Sec. 311 : This product contains the following substances listed in the regulation.
Sodium Nitdte                                                 7632-00-0               5.0-10.0
Additional components may be unintentionally present at trace levels.I Substance(s)
_3                                                ....
I Citations.Sodium Nitdte Sec. 311 CLEAN AIR ACT, Sec. 112 (Hazardous Air Pollutants, as amended by 40 CFR 63), Sec. 602 (40 CFR 82, Class I and II Ozone Depleting Substances):
            "TOXIC-SUBSTANCES         CONTROLA-,CT-(TSCA)
Substances listed under this regulation are not Intentionally added or expected to be present in this product. Listed components may be present at trace levels.CALIFORNIA PROPOSITION 65: Substances listed under California Proposition 65 are not intentionally added or expected to be present in this product.Nalco Company 1601 W. Diehl Road
The substances in this preparation are included on or exempted from the TSCA 8(b) Inventory (40 CFR 710)
* Naperville, Illinois 60563-1198  
FEDERAL WATER POLLUTION CONTROL ACT, CLEAN WATER ACT. 40 CFRA401.15 / formerly Sec. 307.40 CFR 116.4/ formerly Sec. 311 :
* (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.8/10 Attachment NOC-AE-14003142 Page 151 of 155 1tl 1o of 13)SAFETY DATA SHEET A4 PRODUCT.~NALCO ~4. --EMERGENCY TELEPHONE NUMBER(S).(800) 424-9300 (24 Hours) CHEMTREC MICHIGAN CRITICAL MATERIALS:
This product contains the following substances listed in the regulation. Additional components may be unintentionally present at trace levels.
Substances listed under this regulation are not intentionally added or expected to be present in this product. Listed components may be present at trace levels.STATE RIGHT TO KNOW LAWS: The following substances are disclosed for compliance with State Right to Know Laws: Sodium Nitrite 7632-00.0 Sodium Tetraborate 1330-43-4 Water 7732-18-5 CANADIAN ENVIRONMENTAL PROTECTION ACT (CEPA): The substances In this preparation are listed on the Domestic Substances List (DSL), are exempt, or have been repoited in accordance with the New Substances Notification Regulations.
I Substance(s)                                       I Citations
AUSTRALIA All substances in this product comply with the National Industrial Chemicals Notification  
                    . Sodium Nitdte                                   Sec. 311 CLEAN AIR ACT, Sec. 112 (Hazardous Air Pollutants, as amended by 40 CFR 63), Sec. 602 (40 CFR 82, Class Iand II Ozone Depleting Substances):
& Assessment Scheme (NICNAS).CHINA All substances In this product comply with the Provisions on the Environmental Administration of New Chemical Substances and are listed onthe Inventory of Existing Chemical Substances China (IECSC).EU ROPE _________The substances in this preparation have been reviewed for compliance with the EINECS or ELINCS Inventories.
Substances listed under this regulation are not Intentionally added or expected to be present in this product. Listed components may be present at trace levels.
JAPAN All substances in this product comply with the Law Regulating the Manufacture and Importation Of Chemical Substances and are listed on the Existing and New Chemical Substances list (ENCS).KOREA All substances in this product comply with the Toxic Chemical Control Law (TCCL) and are listed on the Existing Chemicals Ust (ECL)PHILIPPINES All substances In this product comply with the Republic Act 8969 (RA 6969) and are listed on the Philippines Inventory of Chemicals  
CALIFORNIA PROPOSITION 65:
& Chemical Substances (PICCS).16. 1 OTHER INFORMATION This product material safety data sheet provides health and safety information.
Substances listed under California Proposition 65 are not intentionally added or expected to be present in this product.
The product Is to be used in applications consistent with our product literature.
Nalco Company 1601 W. Diehl Road
Individuals handling this product should be Informed of the recommended safety precautions and should have access to this information.
* Naperville, Illinois 60563-1198 * (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.
For any other uses, exposures should Nalco Company 1601 W. Diehl Road -Napervil!e, Illinois 60563-1198  
8/10
-(630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.9/10 Attachment NOC-AE-14003142 Page 152 of 155 Attachment J Requested Permit Amendments Admin Report 1. 0, Pg. 1; Tech Report 1.0 -12., Pg. 11 Attachment NOC-AE-14003142 Page 153 of 155 Attachment J -Amendment Requests Request to remove pH monitoring requirements from Internal Outfolls 101, 201, and 501. STP Nuclear respectfully requests the removal of pH limitations and monitoring requirements from its internal monitoring locations.
 
STP feels the requirement to monitor for pH at internal monitoring locations prior to wastewater entering its own cooling reservoir is overly burdensome and has little to no positive environmental impact. In fact, due to efforts by the plant to ensure the pH limits are met, STP must chemically treat these individual wastestreams prior to sampling at the internal monitoring locations.
Attachment NOC-AE-14003142 Page 151 of 155 1o of 1tl    13)
pH treatment would not be necessary to meet the effluent limits at the external Outfall 001 due to natural pH balancing that occurs in the cooling reservoir.
SAFETY DATA SHEET A4                                   PRODUCT.
Request to remove effluent limits and monitoring requirements for relief well discharges at Outfalls 002, 003, 004, 005, and 006 and all associated permit requirements having to do with relief well monitoring.
            ~NALCO                                 ~4.                                         --
STP requests the removal of the monitoring requirements for relief well discharges, placed in the previous TPDES permit draft. The water being discharged is predominantly groundwater that is seeping up to the surface from under the reservoir.
EMERGENCY TELEPHONE NUMBER(S)
The water is not pumped to the surface for discharge.
                                                          .(800) 424-9300 (24 Hours) CHEMTREC MICHIGAN CRITICAL MATERIALS:
STP has been conducting routine monitoring of its relief well discharges in compliance with its TPDES*permit since the permit was issued on April 5, 2012. STP has collected over two years'worth of data in that time. None of the data collected from the relief well monitoring program has exceeded an established effluent limit in the TPDES permit.
Substances listed under this regulation are not intentionally added or expected to be present in this product. Listed components may be present at trace levels.
Attachment NOC-AE-14003142 Page 154 of 155 Attachment K Treatment System Tech Report, Item 2. a., Pg. 3 Attachment NOC-AE-14003142 Page 155 of 155 Wastewater Treatment System Treatment System Outfall Unit Dimensions Treatment Processes Main Cooling Reservoir 001 7,000 acre pond (irregular)
STATE RIGHT TO KNOW LAWS:
Heat Dissipation
The following substances are disclosed for compliance with State Right to Know Laws:
' Reuse/Rlecvcle Low Volume Waste 2-Neutralization Basins Neutralization' Metal Cleaning Wastes** 101 (300,000 gallons each) Mixing*Neutralization Basin 68' x 42'x 16' Sedimentation Gross Oil Separator (API) Equalization Flotation 13,000 gallons Skimming*24.".x 8'x 7'Skmig Low Volume Waste 201 Sedimentation Oily Waste Treatment System Tricellorator (DAF) 3,800 gallons Dissolved air flotation S9'die x 8' CoaquIaton*
Sodium Nitrite                                 7632-00.0 Sodium Tetraborate                             1330-43-4 Water                                         7732-18-5 tNTERNATIONUr*CFEMUCA-CONTROL-WS.
Effluent Tank 850 gallons Multi-media Filtration 5' dia x 6'2-Aeration Basins Screening 63" x 12" x 11 '6' Activated Sludge 2 Clarifiers 16' dia x 11 '6" Sedimentation West Sanitary Waste Treatment Primary Chlorine Contact 401 Chamber Disinfecton..
CANADIAN ENVIRONMENTAL PROTECTION ACT (CEPA):
System*~ 6" x 12' x 1 '6" Secondary Chlorine Contact Chamber Disinfection~'*
The substances In this preparation are listed on the Domestic Substances List (DSL), are exempt, or have been repoited in accordance with the New Substances Notification Regulations.
I 4'dia x 4'3" Organic Basin Equalization Approx. 1,000,000 gallons Mixing*1 00'x 80'x 17'6" Aeration*Metal Cleaning Waste- 501 Inorganic Basin Coagulation' Approx. 50,000 gallons Chemical Precipitation*
AUSTRALIA All substances in this product comply with the National Industrial Chemicals Notification & Assessment Scheme (NICNAS).
25' x 25' x 13'3" Sedimentation Treatment Tanks (possible future Not-determined at this use) time.2-Aeration Basins Screening 54'6" x 12:' x 3'3" Activated Sludge Training Sanitary Waste Treatment 601 1 -Clarifier System** 6 2,0'. da x 133" Sedimentation Chlorine Contact Chamber Disinfection"-" Note: Chlorine may be used intermittently to control algae growth in treatment units.Treatment process may be used based on influent characteristics.
CHINA All substances In this product comply with the Provisions on the Environmental Administration of New Chemical Substances and are listed onthe Inventory of Existing Chemical Substances China (IECSC).
Outfall 501 is routed to Outfall 101. There have been no discharges from Outfall 501 since December 1992.The West Plant is currently rated at 110,000 gallons per day (gpd) and the Training Plant at 66,000 gpd.Sanitary wastewater will increase beginning with the construction of two new electric generating units (3 and 4)and an increase in construction personnel.
EU ROPE                         _________
The physical locations of the treatment systems and Outfalls 401 and 601 may change; however, the outfall descriptions in the permit would remain the same (i.e., monitoring at the discharge from the sewage treatment plant).Disinfection may include sodium hypochlorite or calcium hypochlorite.
The substances in this preparation have been reviewed for compliance with the EINECS or ELINCS Inventories.
Technical Report 1.0 Page 3a}}
JAPAN All substances in this product comply with the Law Regulating the Manufacture and Importation Of Chemical Substances and are listed on the Existing and New Chemical Substances list (ENCS).
KOREA All substances in this product comply with the Toxic Chemical Control Law (TCCL) and are listed on the Existing Chemicals Ust (ECL)
PHILIPPINES All substances In this product comply with the Republic Act 8969 (RA 6969) and are listed on the Philippines Inventory of Chemicals & Chemical Substances (PICCS).
: 16. 1OTHER INFORMATION This product material safety data sheet provides health and safety information. The product Is to be used in applications consistent with our product literature. Individuals handling this product should be Informed of the recommended safety precautions and should have access to this information. For any other uses, exposures should Nalco Company 1601 W. Diehl Road - Napervil!e, Illinois 60563-1198 - (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.
9/10
 
Attachment NOC-AE-14003142 Page 152 of 155 Attachment J Requested Permit Amendments Admin Report 1.0, Pg. 1; Tech Report 1.0 - 12., Pg. 11
 
Attachment NOC-AE-14003142 Page 153 of 155 Attachment J - Amendment Requests Request to remove pH monitoring requirementsfrom Internal Outfolls 101, 201, and 501. STP Nuclear respectfully requests the removal of pH limitations and monitoring requirements from its internal monitoring locations. STP feels the requirement to monitor for pH at internal monitoring locations prior to wastewater entering its own cooling reservoir is overly burdensome and has little to no positive environmental impact. In fact, due to efforts by the plant to ensure the pH limits are met, STP must chemically treat these individual wastestreams prior to sampling at the internal monitoring locations. pH treatment would not be necessary to meet the effluent limits at the external Outfall 001 due to natural pH balancing that occurs in the cooling reservoir.
Request to remove effluent limits and monitoring requirementsfor relief well discharges at Outfalls 002, 003, 004, 005, and 006 and all associatedpermitrequirements having to do with relief well monitoring. STP requests the removal of the monitoring requirements for relief well discharges, placed in the previous TPDES permit draft. The water being discharged is predominantly groundwater that is seeping up to the surface from under the reservoir. The water is not pumped to the surface for discharge. STP has been conducting routine monitoring of its relief well discharges in compliance with its TPDES
*permit since the permit was issued on April 5, 2012. STP has collected over two years' worth of data in that time. None of the data collected from the relief well monitoring program has exceeded an established effluent limit in the TPDES permit.
 
Attachment NOC-AE-14003142 Page 154 of 155 Attachment K Treatment System Tech Report, Item 2. a., Pg. 3
 
Attachment NOC-AE-14003142 Page 155 of 155 Wastewater Treatment System Treatment System                             Outfall   Unit Dimensions                     Treatment Processes Main Cooling Reservoir                         001     7,000 acre pond (irregular)         Heat Dissipation
                                                                              '               Reuse/Rlecvcle Low Volume Waste                                       2-Neutralization Basins             Neutralization' Metal Cleaning Wastes**                         101     (300,000 gallons each)             Mixing*
Neutralization Basin                                   68' x 42'x 16'                     Sedimentation Gross Oil Separator (API)           Equalization Flotation 13,000 gallons                     Skimming*
24.".x 8'x 7'Skmig Low Volume Waste                               201                                         Sedimentation Oily Waste Treatment System                             Tricellorator (DAF) 3,800 gallons   Dissolved air flotation S9'die x 8'                       CoaquIaton*
Effluent Tank 850 gallons           Multi-media Filtration 5' dia x 6' 2-Aeration Basins                   Screening 63" x 12" x 11 '6'                 Activated Sludge 2 Clarifiers 16' dia x 11 '6"       Sedimentation West Sanitary Waste Treatment                           Primary Chlorine Contact 401     Chamber                             Disinfecton..
System*~                                               6" x 12' x 1 '6" Secondary Chlorine Contact Chamber                             Disinfection~'*
I 4'dia x 4'3" Organic Basin                       Equalization Approx. 1,000,000 gallons           Mixing*
100'x 80'x 17'6"                   Aeration*
Metal Cleaning Waste-                         501     Inorganic Basin                     Coagulation' Approx. 50,000 gallons             Chemical Precipitation*
25' x 25' x 13'3"                 Sedimentation Treatment Tanks (possible future   Not-determined at this use)                               time.
2-Aeration Basins                 Screening 54'6" x 12:' x 3'3"               Activated Sludge Training Sanitary Waste Treatment             601     1-Clarifier System**                                       6       2,0'. da x 133"                   Sedimentation Chlorine Contact Chamber           Disinfection"-"
Note: Chlorine may be used intermittently to control algae growth in treatment units.
Treatment process may be used based on influent characteristics.
Outfall 501 is routed to Outfall 101. There have been no discharges from Outfall 501 since December 1992.
The West Plant is currently rated at 110,000 gallons per day (gpd) and the Training Plant at 66,000 gpd.
Sanitary wastewater will increase beginning with the construction of two new electric generating units (3 and 4) and an increase in construction personnel. The physical locations of the treatment systems and Outfalls 401 and 601 may change; however, the outfall descriptions in the permit would remain the same (i.e., monitoring at the discharge from the sewage treatment plant).
Disinfection may include sodium hypochlorite or calcium hypochlorite.
Technical Report 1.0                                                                                             Page 3a}}

Latest revision as of 19:28, 5 February 2020

Texas Pollutant Discharge Elimination System Major Amendment with Renewal Application for a Major Facility Tpdes Permit No. WQ000190800
ML14168A268
Person / Time
Site: South Texas  STP Nuclear Operating Company icon.png
Issue date: 05/01/2014
From:
RPS Group Plc, South Texas
To:
Office of Nuclear Reactor Regulation
Shared Package
ML14168A266 List:
References
Download: ML14168A268 (153)


Text

Attachment NOC-AE-14003142 Page 1 of 155 4180 Delaware Street, Ste 402, Beaumont, Texas 77706, USA T +1 409 838 4400 F +1 409 838 9056 W www.rpsgroup.com Texas Pollutant Discharge Elimination System Major Amendment with Renewal Application for a Major Facility TPDES Permit No. WQ0001908000

(.

Prepared For:

STP Nuclear Operating. Company South Texas Project Electric Generating Station Bay City, Texas May 2014 United States I Canada I Brazil I UK I Ireland I Netherlands Australia Asia Pacific I Russia I Middle East I Africa

Attachment NOC-AE-14003142 Page 2 of 155 41A0 Delaware Street, Ste 402', BeauMont, Texas 77706, USA T +1 40.9 838 4400. P 4.1 ,409 938 9056 W www,rpsgroup.com May 29, 2014 MAY 29 2014 vi~Erf' QUALITy DIVISION Executive Director Applications Review and Processing.Team (MC148)

Texas Commission on Environmental OLrIality 12100 Park 35 Circle Austin, TX 78753 RE: ApplicatIon for the Renewal with Major Amendment of TPDES Permit No.

WQ000.1908000 South: Texas Project Nuclear Operating Company (STP)

Dear Sir:

On behalf of.STP, we are submitting the. enclosed permit renewal with major amendment application for the above referenced Texas Pollutant Discharge Elimination System (TPDES) permit. Enclosed you will find one original and three complete copies for your approval. The application fee has.been submitted directly to the Financial Administration Division under separate cover, however, a copy of the fee submitta9l is presented in Attachment A.

If you have any questions concerning this ýappl!tation, please contact me at 512-326-5859... We look forward to working with. you In prooessing this application. Thank you for your consideration, Sincerely, Tres Koenings Senior Consultant I

UnIted States IlCan~ada.l0razi I UK I.lIr~land I N~etherlands Austealla A.91a.Pbocflo I Rusela I Middle East I Africa Atnonebir of RPS. Groulp P/C

Attachment NOC-AE-14003142 Page 3 of 155 TABLE OF CONTENTS TCEQ Industrial Wastewater Permit Application TPDES Permit No. WQ0001908000 Submission Checklist Industrial Administrative Report 1.0 Industrial Administrative Report 1.1 Supplemental Permit Information Form Industrial Technical Report 1.0 Worksheet 1.0 EPA Effluent Guidelines Worksheet 2.0 Pollutant Analyses Requirements Worksheet 4.0 Receiving Waters Worksheet 5.0 Sewage Sludge Management and Disposal Worksheet 7.0 Storm Water Runoff Attachment A Copy of Application Fee (Submission Checklist, Pg.. 1)

Attachment B USGS Map (Admin Report 1.0 - 8.m., Pg. 12)

Attachment C Affected Landowners (Admin Report 1.1 - l.a. & b., Pg. 15)

Attachment D Original Photographs (Admin Report 1.1- 2., Pg. 12)

Attachment E USGS Map (SPIF, Item 8)

Attachment F Wastewater Generating Process (Tech Report 1.0 1 .c., Pg. 1)

Attachment G Facility Plot Plan (Tech Report 1.0 - I.e., Pg. 2)

Attachment H Flow Schematic Diagrams (Tech Report 1.0 - 2.b., Pg. 3)

Attachment I Water Treatment Chemicals (Tech Report 1.0 - 5.c., Pg. 8)

Attachment J Requested Permit Amendments (Admin Report 1.0, Pg. 1; Tech Report 1.0 -12., Pg. 11)

Attachment K Treatment System (Tech Report, Item 2. a., Pg. 3)

J:\Projects\STP Nuclear\Application\STP Nuclear Amendment with Renewal Application~doc

Attachment NOC-AE-14003142 Page 4 of 155 Submission Checklist

Attachment NOC-AE-14003142 Page 5 of 155 TEXAS COMMISSION ON ENVIRONMENTAL QUALITY TCEQ INDUSTRIAL WASTEWATER PERMIT APPLICATION INDUSTRIAL ADMINISTRATiVE REPORT Submit this checklist with the application. Do not submit the instructionswith the application.Indicateif thefollowing are included in the application.

Applicant STP Nuclear Operating Company Permit Number WQ0001 908000 Administrative Report 1.o W Worksheet 7.0 W E Administrative Report 1.1 F7f JF Worksheet 8.0 F71 -

SPIF i [7] Worksheet 9.o 17 Li Technical Report 1.0 . Worksheet 0o.o0] [

Worksheet 1.o . original OF] USGS Map El Worksheet 2.0 - [-I. Affected Landowners Map . -

Worksheet 3.0 EL i:Y Landowner Disk or Labels , -] I1 Worksheet 3.1 1- [] Copy of Application Fee Check. V 01 Worksheet3.2 F-/ "All fees owed TCEQ are paid Z DI Worksheet 3.3 [] [] Flow Diagram Worksheet 4.0 [ , _ Site Drawing Worksheet 4.11 Original Photographs .. _

Worksheet 5.0 i _, Solids Management Plan FE] I Worksheet 6.0 ].- L2] Water Balance 0J rV Please indicate by a check mark the amount submi tted for the application fee: See Attachment A elld...: -ajoo Mnor ".:...

or&med. ..

.PA dassificatori New ond Rwieid Withut.Qnl /-M 0d.

Minor facility not subject to categorical standards ____$350 -___$350 ____$315 -___$150 promulgated by the EPA (40 CFR Part 4oo-471)

Minor facility subject to categorical standards ____$1,250 -___$1250 ____$12-15 ____$150 promulgated by the EPA (40 CFR Part 400-471) ______

Major facility N/A * Ž..$2,050 __ _$2-,015 - $450

'~All facilities are designated as minors until formally classified as a major by EPA.

-For C~fifimissioim Use 'Only-Se.ge'nieit Nunbr:bt:, § ICuny prtlnDte:_______

Troposed/CurrentlrI'emt N~ub&': __________ei I

TCEQ-1 0411 (9/1/2010) Industrial Wastewater Permit Application - Administrative Report Page 1 of 18

Attachment NOC-AE-14003142 Page 6 of 155 Industrial Administrative Report 1.0

Attachment NOC-AE-14003142 Page 7 of 155 INDUSTRIAL ADMINISTRATIE REPORT 1.O The following is requiredforall applications--Renewal,New, And Amendment Type of application:

B NewTPDES j NewTLAP Major amendment with Renewal Major Amendment without Renewal

' Renewal of existing permit EJ Stormwater only discharge M Minor amendment to permit 0 Minor modification to permit If applying for an amendment to a permit, please describe the request in detail. See Attachment J

-The applicant Is requesting the removal of effluent limitations and monitoring requirements for Outfalls 002-006, Relief Well Monitoring Ouffalls.

-The applicant Is requesting the removal of pH monitoring requirements at Internal Outfalls 101, 201, and 501.

a. Facility Owner (Owner of the facility must apply for the permit.)

What is the Legal Name of the entity (applicant) applying for this permit?

STP Nuclear Operating Company (The legal name must be spelled exactly asfiled with the Texas Secretary of State, County, or in the legal document forming the entity.)

If the applicant is currently a customer with TCEQ, what is the Customer Number (CN)? Search for your CN at:

http:/!wwwV2.tceq.texas.gov/crpub/index.cfm?fuseaction=cust.CustSearch CN601658669 What is the name and title of the person signing the application?

(The person must be an executive official meeting signatory requirements in TAC 305.43(a).)

Prefix (Mr. Ms, Miss): Mr.

First/Last Name: Michael P. Murray Suffix:

Title:

Manager, Regulatory Affairs Credential:

What is the applicant's mailing address as recognized by the US Postal Service?

You may verify the address at: http://zip4.usps.com/zip4/welcome.Isp Organization Name: STP Nuclear Operating Company Mailing Address: P.O. Box 289 Internal Routing (Mail Code, Etc.): N6016 City: Wadsworth State: Xx ZIP Code: 77483 Mailing Information if outside USA Territory: Country Code: Postal Code:

Phone No.: (361) 072-8164 Extension:_

Fax No.: E-mail Address:

TCEQ-10411 (911/2010) Industrial Wastewater Permit Application - Administrative Report Page 2 of 18

Attachment NOC-AE-14003142 Page 8 of 155 Indicate the type of Customer:

[ Individual El Sole Proprietorship-D.B.A.

[ Limited Partnership El Corporation

[ Trust C3 Estate

[ Federal Government El State Government C County Government Cj City Government C Other Government ED Other:

Independent entity E Yes E] No (If governmental entity; subsidiary,or partof a largercoiporation)

Number of Empio es:

E0-20; [ 21-100; o 101-250; Lj 251-500; or 7 501 or higher Customer Business Tax and Filing Numbers (Not applicable to individuals, governments, general partnershipsor sole proprietors.REQUIREDfor corporationsand limited partnerships)

State Franchise Tax ID Number: 1-76-0517597-9 TX SOS Charter (filing) Number: 1459553-01 Federal Tax ID:

DUNS Number (if known):

b. Co-Permittee information (complete only if the operator must be a co-permittee)

What is the Legal Name of the entity (operator) applying for this permit?

Operator N/A (The legal name must be spelled exactly as filed with the Texas Secretary of State, County, or in the legal documentforming the entity.)

If the operator is currently a customer with TCEQ, what is the Customer Number (CN)? Search for your CN at:

http://www12.tceq.texas.gov/crpub/index.cfm?fLiseaction=cust.CustSearch CN.

What is the name and title of the person signing the application?

(The person must be an executive official meeting signatory requirements in TAC 305.43(a).)

Prefix (Mr. Ms, Miss):

First/Last Name:

Suffix:

Title:

Credential:

What is the applicant's mailing address as recognized by the US Postal Service?

You may verify the address at: http: //zip4.usps.com/zip4/welcome.jsD TCEQ-10411 (9/1/2010) Industrial Wastewater Permit Application - Administrative Report Page 3 of `18

Attachment NOC-AE-14003142 Page 9 of 155 Organization Name:

Mailing Address:

Internal Routing (Mail Code, Etc.):__

City: State: ZIP Code:

Mailing Information if outside USA Territory: Country Code: _Postal Code.,

Phone No.: ____ Extension:

Fax No., E-mail Address:

Indicate the type of Customer:

E] Individual [ Sole Proprietorship-D.B.A.

El Limited Partnership D Corporation l Trust t Estate D Federal Government E State Government t* County Government fl City Government

[* Other Government l Other:

Independent entity 0 Yes E3 No (If governmentalentity, subsidiary,or partof a largercorporation)

Number of Employees:

0-20;21-100; E 101-250; 0 251-500; or E 501 or higher Customer Business Tax and Filing Numbers (Not applicableto individuals, governments, generalpartnershipsor sole proprietors.REQUIREDfor corporationsand limited partnerships)

State Franchise Tax ID Number:

TX SOS Charter (filing) Number:

Federal Tax ID:

DUNS Number (if known):

Provide a brief description of the need for a co-permittee:

TCEQ-10411. (9/1/2010) Industrial Wastewater Permit Application -Administrative Report Page 4 of 18

Attachment NOC-AE-14003142 Page 10 of 155

c. Individual information (complete only if thefacility owner or co-permittee is an individual)

What is the Legal Name of the owner/co-permittee applying for this permit?

N/A If the owner/co-permittee is currently a customer with TCEQ, what is the Customer Number (CN)? Search for your CN at:

http:!/wwwl2.tceg.texas.gov/crpub/index.cfm?fuseaction=cust.CustSearch CN What is the name and title of the person signing the application?

(The person must be the individual. See signatoly requirements in TAC 305.43(a).)

Prefix (Mr. Ms, Miss):.

First/Last Name:

Suffix:

State Identification Number:

Date of Birth:

Assumed business or professional name:

Business name:

What is the applicant's mailing address as recognized by the US Postal Service?

You may verify the address at: http://zip4.usps.com/ziP4/welcome.'sm Mailing Address:

Internal Routing (Mail Code, Etc.):

City: State: TX ZIP Code:.

Mailing Information if outside USA Territory: Country Code: _Postal Code:

Phone No.: Extension:

Fax No.: E-mail Address:

a. Billing Contact and Address Information The permittee is responsiblefor paying the annualfee. The annualfee will be assessed to permits active on September 1 of each year. TCEQ will send a bill to the addressprovided in this section. The permittee is responsiblefor terminatingthe permit when it is no longer needed.

Is the billing address the same as the permittee or co-permittee?

E] Permittee [ Co-permittee l No, fill out this section Prefix (Mr, Ms, Miss): Mr.

First/Last Name: John Hoffman Suffix:

Title:

Staff Environmental Consultant Credential:_

Organization Name: STP Nuclear Operating Company Billing Mailing Address: P.O. Box 289 TCEQ-10411 (9/1/2010) Industrial Wastewater Permit Application - Administrative Report Page 6 of 18

Attachment NOC-AE-14003142 Page 11 of 155 Internal Routing (Mail Code, Etc.): N2019 City: Wadsworth State: TX ZIP Code: 77483 Mailing Information if outside USA.

Territory:. Country Code: Postal Code:

Phone No.: (361) 972-4507 Extension:

Fax No.: E-mail Address: jphoffman@stpegs.eom If TCEQ needs additional information regarding this application, who should be contacted?

a. Application Contact Prefix (Mr. Ms, Miss): Mr.

First/Last Name: John Hoffman Suffix:

Title:

Staff Environmental Consultant Credential:

Organization Name: STP Nuclear Operating Company Mailing Address: P.O. Box 289 Internal Routing (Mail Code, Etc.): N201 9 City: Wadsworth State: TX ZIP Code: 77483 Mailing Information if outside USA.

Territory: Country Code: Postal Code:

Phone No.: (361) 972-4507 Extension:

Fax No.: E-mail Address: Jphoffman@stpegs.com Check one or both: F Administrative contact n/ Technical Contact

b. Application Contact Prefix (Mr. Ms, Miss): Mr.

First/Last Name: Tres Koenings Suffix:

Title:

. Senior Consultant Credential:

Organization Name: RPS Mailing Address: 4801 Southwest Parkway, Parkway 2, Suite 150 Internal Routing (Mail Code, Etc.):

City: Austin State: TX ZIP Code: 78735 Mailing Information if outside USA.

Territory: Country Code: Postal Code:

Phone No.: (512) 326-56L9 Extension:

Fax No.: E-mail Address: tres.koenlngs@rpsgroup.com Check one or both: : F Administrative contact 0 Technical Contact TCEQ-1 0411 (9/1/2010) Industrial Wastewater Permit Application - Administrative Report Page 6 of 18

Attachment NOC-AE-14003142 Page 12 of 155

!*:¢

% *.i!='

  • :*."'?........... ',¢ *' *""-¢"**"i"! ........ i":.....
  • " '='.;
~i":!*''*'*=-'

i"...

"......."... ~i**i

  • !?*~ii*-,'ii:?:!'.:*:.*:!

Contact Responsible for Discharge Monitoring Reports (EPA 3320-1) Provide the name of the person and their complete mailing address delegated to receive and submit Discharge Monitoring Report Forms.

Prefix (Mr. Ms, Miss): Mr.

First/Last Name: John Hoffman Suffix:

Title:

Staff Environmental Consultant Credential:

Organization Name:, STP Nuclear Operating Company Mailing Address: pKo. Box 289 Internal Routing (Mail Code, Etc.): N2019 City: Wadsworth State: TX ZIP Code: 77843 Mailing Information if outside USA.

Territory: Country Code: Postal Code:

Phone No.: (361) 972-4507 Extension:

Fax No. E-mail Addre-ss jphoffman stpegs.com Did you know you can submit DMR data on line?

Go to Sign up now at:

letl-zb https: /!www6.tceq.texas.gov/steers/

Establish an electronic reporting account when you get your permit number.

Provide two names of individuals that can be contacted throughout the permit term.

Prefix (Mr. Ms, Miss): Mr.

First/Last Name: John Hoffman Q, , ATIA4 .

"UXLAA,

Title:

Staff Environmental Consultant Credei Organization Name: STP Nuclear Operating Company Mailing Add'ess: P.O. Box 289 Internal Routing (Mail Code, Etc.): N2019 City: Wadsworth State: TX ZIP Code: 77843 Mailing Information if outside USA.

Territory: Country Code: Postal Code:

Phone No.: (361) 972-4507 Extension:

Fax No.: E-mail Address: Jphoffman@stpegs.com TCEQ-10411 (911/2010) Industrial Wastewater Permit Application - Administrative Report Page 7 of 18

Attachment NOC-AE-14003142 Page 13 of 155 Prefix (Mr. Ms, Miss): Ms.

First/Last Name: P.L. Travis Suffix:

Title:

Environmental Supervisor Credential:

Organization Name: STP Nuclear Operating Company Mailing Address: P.O. Box 289 Internal Routing (Mail Code, Etc.): N2019 City: Wadsworth State: TX ZIP Code: 77843 Mailing Information if outside USA.

Territory: Country Code: Postal Code:

Phone No.: (361) 972-8573 Extension:

Fax No.: E-mail Address: pltravls@stpegs.com

a. Individual publishing the notices Prefix (Mr. Ms, Miss): Mr.

First/Last Name: John Hoffman Suffix:

Title:

Staff Environmental Consultant Credential:__

Organization Name: STP Nuclear Operating Company Mailing Address: P.O. Box 289 Internal Routing (Mail Code, Etc.): N2019 City: Wadsworth .State: TX ZIP Code: 77843 Mailing Information if outside USA.

Territory: Country Code: Postal Code:_

Phone No.: (361) 972-4507 Extension:

Fax No.: E-mail Address: jphoffman@stpegscom

b. Method for receiving Notice of Receipt and Intent to Obtain a Water Quality Permit Package Indicate by a check mark the preferred method for receiving the first notice and instructions:

[21 E-mail Address: Jphoffman@stpegs.com

[] Fax No.:

El Overnight/Priority mail: (self addressed, prepaid envelope required)

[] Regular Mail:

Mailing Address:

Internal Routing (Mail Code, Etc.):_

City: State: TX ZIP Code:

c. Contact in the Notice TCEQ-10411 (911/2010) Industrial Wastewater Permit Application - Administrative Report Page 8 of 18

Attachment NOC-AE-14003142 Page 14 of 155 Prefix (Mr. Ms, Miss): Mr.

First/Last Name: John Hoffman Suffix:

Title:

Staff Environmental Consultant Credential:

Organization Name: STP Nuclear Operating Company Phone No.: (361) 972-4507 Extension:

d. Public Place Information If thefacility and/oroutfall are located in more than one county, a public viewing placefor each county must be provided.

Public Building name: Matagorda County Courthouse Location within the building: County Clerks Office Physical address of building: 1700 7th Street City: Bay City County: Matagorda Contact Name: Janet Hlckl Phone No.: (970) 244-7680 Extension:

e. Bilingual Notice Requirements:

For new permit, major amendment and renewal applications. Not applicable for minor amendment or minor modification applications.

Please call the bllingual/ESL coordinator at the nearest elementary and middle schools and obtain the following Information to determine if an alternative language notice is required:

1. Is a bilingual education program required by the Texas Education Code at the nearest elementary or middle school to the facility or proposed facility?

n- Yes nN No (If No, alternative language notice publication is not required; skip to item 7. SITE INFORMATION.)

2. Are the students who attend either the elementary school or the middle school enrolled in a bilingual education program at that school?

0 Yes [3 No

3. Do the students at these schools attend a bilingual education program at another location?

0 Yes [] No

4. Would the school be required to provide a bilingual education program but the school has waived out of this requirement under 19 TAC §89.1205(g)?

[7 Yes 0 No

5. If the answer is yes to 1, 2, 3, or 4, public notice in an alternative language is required. Which language is required by the bilingual program?

This section of the applicationis only used to determine if alternative language notice will be needed. Complete instructionson publishing the alternative languagenotice will be in your public noticepackage.

TCEQ-1 0411 (9/1/2010) Industrial Wastewater Permit Application - Administrative Report Page 9 of 18

Attachment NOC-AE-14003142 Page 15 of 155 If the site of your business is part of a larger business site, a Regulated Entity Number (RN) may already be assigned for the larger sitt. Use the RN assigned for the larger site. Search TCEQ's Central Registry to see if the larger site may already be registered as a regulated site at:

http: //wwwl2.tceeq.texas.gov/crpub/index.cfm?ftseaction=regent.RNSearch If the site is found, provide the assigned Regulated Entity Reference Number and provide the information for the site to be authorized through this application below.

The site information for this authorization may vary from the larger site information.

TCEQ issued RE Reference Number (RN): RN 102395654

a. State/TPDES Permit No.: WQ0001908000 Expiration date: 12/01/2014 EPA Identification No. (TPDES Permits only): TX 06 49 47 0
b. Name of project or site (the name kmown by the community where located):

South Texas Project Electric Generating Station

c. Is the facility located in Bexar Comal Hays, Kinney, Medina, Travis, Uvalde, or Williamson County? l Yes lNo (If Yes, additional Information concerning protection of the Edwards Aquifer may be required.)
d. Is the location of the facility used in the existing permit correct? ED Yes ONo
e. Does the site have a physical address?

If Yes, complete Section A for a physical address.

If No (the location description is not accurate or this is a new permit application, complete), complete Section B for site location information.

Se~ction, A; E ter:thBph*cal addre~s for thg~le, *:<:, :',,: ,. ::,* >*1 ;:::*:!:

Verify the address with USPS. If the address is not recognized as a delivery address, provide the address as identified for overnight mail delivery, 911 emergencies, or other online map tool to confirm an address.

PhysicalAddress of Projector Site:

Street Number: 12090 Street Name: Farm-to-Market Road 521 City: Wadsworth ZIP Code: 77483 Seck~ns~ ute t e iomatln, ri~-~cto If no physical address (Street Number & Street Name), provide a written location I

access description to the site:

(Ex.: located 2 miles west from intersection of Hwy 29o & IH35 accessible on Hwy 29o South)

TCEQ-10411 (9/1/2010) Industrial Wastewater Permit Application - Administrative Report Page 10 of 18

Attachment NOC-AE-14003142 Page 16 of 155

f. City where the site is located or, if not in a city, what is the nearest city:

Wadsworth

g. ZIP Code where the site is located: 77483
h. County where the site is located Matagorda
i. Latitude: 28' 47' 50" N Longitude: 96' 03' 10" W
j. In your own words, briefly describe the primary business of the Regulated Entity:

(Do not repeat the SIC andNAICS code)

FSteam Electric Generating Facility

k. Owner of treatment facility: STP Nuclear Operating Company Ownership of Facility: E Public 1-/ Private ] Both lZLFederal
1. Owner of land where treatment facility is/will be: STP Nuclear Operating Company (If not the same as the facility owner, there must be a long term lease agreement in effect for at least six years. In some cases, a lease may not suffice - see instructions.)
m. Owner of effluent disposal site: N/A (If not the same as the facility owner, there must be a long term lease agreement in effect for at least six years.)
n. Owner of sewage sludge disposal site: N/A (Required only If authorization is sought in the permit for sludge disposal on property owned/controlled by the applicant.)
a. Is the point of discharge and discharge route in the existing permit correct?

V1 Yes 0 No If no, or a new or amendment permit application, please give an accurate description.

N/A

b. City or Town in which the outfall(s) is or will be located Near Bay City
c. County the outfall(s) is located: Matagorda
d. Ogtfate atitud 001:280 44' 48"N Longitude: 001: 960 00' 02"W eee-low foredditional outfalls,
e. For all applications involving an average daily discharge of 5 million gallons per day or more, provide the names of all counties located within loo statute miles downstream of the point(s) of discharge. N/A
  • Oultfall 002: 28°46'29"N 950 59' 53" W; Outfall 003: 28°44'49"N 96 0 00'40"W; Outfall 004:28"44'57"N 96001'03"; Outfall 005: 28 044'32"N 96 0 02'42"W; Outfall 006: 28 0 44'31"N 96 003'36"W TCEQ-10411 (9/1/2010) Industrial Wastewater Permit Application - Administrative Report Page 11 of 18

Attachment NOC-AE-14003142 Page 17 of 155

f. If a TLAP, is the location of the effluent disposal site in the existing permit accurate?

[ Yes Eu No If no, or a new or amendment permit application, please give an accurate description.

N/A

g. City or Town in which the disposal site is or willbe located N/A
h. County the disposal site is located: N/A
i. Disposal Site Latitude: N/A Longitude: N/A
j. If a TLAP, describe the routing of effluent from the treatment facility to the effluent disposal site:

N/A

k. For TLAP applications please identify the nearest watercourse to the disposal site to which rainfall runoff might flow if not contained: N/A
1. Is the location of the sewage sludge disposal site in the existing permit accurate?

- Yes r No If no, or a new permit application, please give an accurate description.

N/A

m. Provide an original full size USGS Topographic Map with all required information.

Indicate by a check mark that the information is provided. See Attachment B j Applicant's property boundary D Treatment facility boundaries nN Labeled point of discharge and highlighted discharge route

[-] Sewage sludge disposal site

-] Effluent disposal site boundaries

[j New and future construction on i mile radius and 3 miles downstream information V All ponds

n. Is/will the treated wastewater discharge to a city, county, or state highway right-of-way, or a flood control district drainage ditch? LI Yes [] No If Yes, indicate by a check mark if: N/A

[- Authorization granted [I Authorization pending (For new and amendments, provide copies of letters that show proof of contact and the approval letter upon receipt.)

TCEQ-10411 (9/1/2010) Industrial Wastewater Permit Application -Administrative Report Page 12 of 18

Attachment NOC-AE-14003142 Page 18 of 155

o. Is the facility located on or does the treated effluent cross American Indian Land?

DYes MY No

a. List each person formerly employed by the TCEQ who represented your company and was paid for service regarding the application:

Tres Koenings, Jamie Saladiner

b. Do you owe fees to the TCEQ? EL Yes 70 No If yes, please provide:

Account number: Amount past due:

c. Do you owe any penalties to the TCEQ? F] Yes [] No If yes, please provide:

Enforcement order number Amount past due TCEQ-10411 (9/1/2010) Industrial Wastewater Permit Application - Administrative Report Page 13 of 18

Attachment NOC-AE-14003142 Page 19 of 155 Permit Number: WQ0001908000 Applicant; STP Nuclear Operating Company Certification:

I, Michael P. Murray Manager, Regulatory Affairs Typed or printed name Title certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware there are significant penalties for submitting false information, including thepossibility of fine and imprisonment for knowing violations.

I further certify that I am authorized under 30 Texas Administrative Code §305.44 to sign and submit this document, and can provide documentation in proof'of such authorization upon request.

Signature: Date: 2 /*

,*2 (Use l"e k)

Subscribed and Sworn to before me by the said- M* c\ c\ ýA \ L*t(Ctu on this dayof o2

,20 My commission expires on the LAh- day of I ,2o )WL

\~ [SEAL]

Notary Public County, Texas tf co-permittees are necessary, each entity must submit an original, separatesignaturepage.

TCEQ-1041 i (9/1/2010) Industrial Wastewater Permit Application -Administrative Report Page 14 of 18

Attachment NOC-AE-14003142 Page 20 of 155 Industrial Administrative Report 1.1

Attachment NOC-AE-14003142 Page 21 of 155 INDUSTRIAL ADMINISTRATIVE REPORT 1.1 Thefollowing is requir'edfor new and amendment applications.

See Attachment C

a. Indicate by a check mark that the landowners map or drawing, with scale, includes the following, as applicable.

[A The applicant's property boundaries

[El The facility site boundaries within the applicant's property boundaries FD The distance the buffer zone falls into adjacent properties and the property boundaries of the landowners located within the buffer zone

[E The property boundaries of all landowners surrounding the applicant's property

[ The point(s) of discharge and highlighted discharge route clearly shown for one mile downstream

  • The property boundaries of the landowners located on both sides of the discharge route for one full stream mile downstream of the point of discharge

[E The property boundaries of the landowners along the watercourse for a one-half mile radius from the point of discharge if the point of discharge is into a lake, bay estuary, or affected by tides F The boundaries of the effluent disposal site (for example, irrigation area or subsurface drainfield site), all evaporation/holding ponds within the applicant's property El The property boundaries of all landowners surrounding the applicant's property boundaries where the effluent disposal site is located El The boundaries of the sludge land application site (for land application of sewage sludge for beneficial use) and the property boundaries of landowners surrounding the applicant's property boundaries where the sewage sludge land application site is located E The property boundaries of landowners within one-half mile in all directions from the applicant's property boundaries where the sewage sludge disposal site (for example, sludge surface disposal site or sludge monofill) is located

b. Indicate by a check mark in which format the landowners list is submitted:

[N Read/Writeable CD or Disk [-l 4 sets of labels

c. Indicate by a check mark that a separate list with the landowners' names and mailing address cross-referenced to the landowners map has been provided. [E
d. Provide the source of the landowners' names and mailing addresses.

Matagorda County Appraisal District, 2014 Parcel Boundary & 2013 Tax Roll TCEQ-1 0411 (9/1/2010) Industrial Wastewater Permit Application - Administrative Report Page 15 of 18

Attachment NOC-AE-14003142 Page 22 of 155

c. As required by Texas Water Code §5.115, is any permanent school fund land affected by this application? [] Yes [] No If yes, provide the location and foreseeable impacts and effects this application has on the land(s).

. . ... .~ .i`*

...... ~~ ~ ~~ ~ ~~~ ~~~......

.`.:-.:*y . i.?! i;* *% `

Provide original ground level photographs. Indicate by checking that the following information is provided. See Attachment D El At least one original photograph of the new or expanded treatment unit location

[ At least two photographs of the existing/proposed point of discharge and as much area downstream (photo i) and upstream (photo 2) as can be captured.

F- If the discharge is to an open water body (e.g., lake, bay), the point of discharge should be in the right or left edge of each photograph showing the open water and with as much area on each respective side of the discharge as can be captured, El At least one photograph of the existing/proposed effluent disposal site AJ A plot plan or map showing the location and direction of each photograph TCEQ-1 0411 (9/1/2010) Industrial Wastewater Permit Application - Administrative Report Page 16 of IS

Attachment NOC-AE-14003142 Page 23 of 155 Supplemental Permit Information Form

Attachment NOC-AE-14003142 Page 24 of 155 TEXAS COMMISSION ON ENVIRONMENTAL QUALITY SUPPLEMENTAL PERMIT INFORMATION FORM (SPIF)

FOR AGENCIES REVIEWING INDUSTRIAL TPDES WASTEWATER PERMIT APPLICATIONS T-CJQ VSE ONLY: -

APPlieat~i6n~type., 'iiRenewal Majot Amnendment Minor Amendrtient -New cýOtnty:_ Segment Number -_Admin Com~plete Date:_______

Agency Receiving SPIV:

___Texas H-istorical commfns~ion- US Fish and WAildlife This form applies to TPDES permit applications only. (Instructions, Page 34)

The SPIF must be completed as a separate document. The TCEQ will mail a copy of the SPIF to each agency as required by the TCEQ agreement with EPA. If any of the items are not completely addressed and/or further information is needed, you will be contacted to provide the information before the permit Is issued. Each item must be completely addressed.

Do not refer to a response of any item in the permit application form. Each attachment must be provided with this form separately from the administrative report of the application. The application will not be declared administratively complete without this form being completed in its entirety including all attachments.

The following applies to all applications:

1. Permlttee: STP Nuclear Operating Company
2. Permit No. WQoo 0 1 9 0 8 0 0 0 (EPA ID No.) TX 0 0 6 4 9 4 7
3. Address of the project (location description that includes street/highway, ity/vicinity, & county) 12090 Farm-to-Market Road 521, Wadsworth, Texas 77483
4. Provide the name, address, phone and fax number of an individual that can be contacted to answer specific questions about the property.

Name: John Hoffman Company: STP Nuclear Operating Company Phone number: (361) 972-4507 Fax number:

Street No.: Street name: Street type:

P.O. Box, 289 City: Wadsworth State: TX ZIP code: 7 7 4 8 3 Email: jphoffman@stpegs.com TCEQ-10411 (9/1/2010) Industrial Wastewater Permit Application - Administrative Report Page 17 of 18

Attachment NOC-AE-14003142 Page 25 of 155

5. List the county in which the facility is located:.Matagorda
6. If the property is publicly owned and the owner is different than the permittee/applicant, please list the owner of the property.

N/A

7. Provide a description of the effluent discharge route. The discharge route must follow the flow of effluent from the point of discharge to the nearest major watercourse (from the point of discharge to a classified segment as defined in 30 L

TAC Chapter 307). If known, please identify the Segment Number.

'aOt directh, lo Co0oraao Rlver t12al; via M2etome Plant.areaDrainage Dto, then tO'Coorado *liverTidal; via 002 to an unnamed oitch, loen 1 an unnamed trbutar of West Branh of Colorado River, then to West Branch of Colorado River, then to Mategorda Bay/Powderhomr Lake: via 004 to en unnamed ditch then to Colorado RiverI Tidal InSegment No. 1401 of Colorado River Baon; via 005 to East Fork Little RobbinaSlough, then to Robbins Slough, then to Robbins Lake, than to Robbins Slough, Ithen to Crab Lake, then to Crab Bayou, then to Gulf Intercoastal Waterway, then to Metagorda Bay/Powderhorn Lake; and via 006 to LittleRobbing Slough, then to an

- O_'M H.... . ... . . ks... .. to

. . .... to m-...... . W . . . .. . .i In '. . *. . I

.'.. .' e ' , . . ft.

Intercoastal Waterway, .hen to Matagorda Bey/Powderhom Lka In Segment No. 2451 of theBays and vatuarles

8. Please provide a separate 7.5 minute USGS quadrangle map with the project boundaries plotted and a general location map showing the project area. Please highlight the discharge route from the point of discharge for a distance of one mile downstream. (This map is required in addition to the map in the administrative report). See Attachment E
9. Provide original photographs of any structures 50 years or older on the property.

io. Does your project involve any of the following? Check all that apply.

n] a. Proposed access roads, utility lines, construction easements D1 b. Visual effects that could damage or detract from a historic property's integrity H c. Vibration effects during construction or as a result of project design

d. Additional phases of development that are planned for the future
e. Sealing caves, fractures, sinkholes, other karst features
f. Disturbance of vegetation or wetlands ii. List proposed construction impact (surface acres to be impacted, depth of excavation, sealing of caves, or other karst features).
12. Describe existing disturbances, vegetation and land use.

THIE FOLLO;W.-NG ITEMS-` POPLYO L QAPI'IN O E TPES PEIIMTTSý AD MAJOQ"-R;AMENDMENTS TO PDE 1MfS

13. List construction dates of all buildings and structures on the property.

.NN/A

14. Provide a brief history of the property, and name of the architect/builder, if known.

TCEQ-1 0411 (9/1/2010) Industrial Wastewater Permit Application - Administrative Report Page 18 of 18

Attachment NOC-AE-14003142 Page 26 of 155 Industrial Technical Report 1.0

(

Attachment NOC-AE-14003142 Page 27 of 155 TECHNICAL REPORT 1.o INDUSTRIAL THE FOLLOWING IS REQUIRED FOR ALL APPLICATIONS RENEWAL, NEW, AND AMENDMENT

a. Describe the type of activity and general nature of your business.

South Texas (STP) Electric Generating Station is a nuclear fueled, steam-electric generating facility. Electricity is generated from steam driven turbines.

b. SIC Code(s) 4911 , ,

NAICS Code(s) 221113 , ,

c. Describe the wastewater generating processes.

See Attachment F

d. Provide a list of raw materials, major intermediates, and products handled at your facility.

Raw Materials Intermediate Products Final Products Nuclear Fuel (7440-61-1) Steam Electricity TCEQ-10055 (05/15/2012) Industrial Wastewater Permit Application Technical Report Page I of 66

Attachment NOC-AE-14003142 Page 28 of 155

e. Indicate by a check mark that an attached facility map with the following information was provided with the application:

[1 Production areas, maintenance areas, materials handling areas, and waste disposal areas.

[71 The location of each unit of the wastewater treatment plant including the location of wastewater collection sumps and impoundments.

Attachment #: G

f. Is this a new permit application for an existing facility? ED Yes IZ No If yes, provide background discussion below.

N/A

g. Is the treatment facility/disposal site located above the 1oo-year frequency flood level?

fZYes F No List source(s) used to determine 1oo-year frequency flood plain:

FIRM 485489037C, March 18, 1985 If no, provide the elevation of the 1o0-year frequency flood plain and describe what protective measures are in use or planned to be used to prevent flooding of the treatment facility/disposal area.

N/A

h. For new or amendment permit applications, will there be discharge of fill material into a water in the state for construction of the proposed outfall structure? El Yes W1 No If no, proceed to Item No. 2. If yes, has the a plicant applied for a U.S. Corps of Engineers 404 Dredge and Fill permit? [_Yes LI No If yes, provide the permit number:

If no, provide the approximate date you anticipate submitting your application to the Corps.

TCEQ-10055 (05/15/2012) Industrial Wastewater Permit Application Technical Report Page 2 of 66

Attachment NOC-AE-14003142 Page 29 of 155

a. List any physical, chemical, an/or biological treatment process that y ou use f or the treatm ent of wastewater at your facility. Include a description of each treatment process starting with initial treatment and finishing with the discharge point.

See Attachment K

b. [] Indicate by a check mark t hat an attached flow schematic with a water balance was provided with the applications showing each treatment unit and all sources of wastewater flow into the treatment plant and to each outfall/point of disposal.

Attachment #: H Do you use or plan to use any wastewater lagoons, ponds, or impoundments 71 YesR No If yes, complete item 3(a) for existing impoundments and items 3(a)-3(t) for new or proposed impoundments. If no, proceed to Item No. 4.

a. Provide the following information in the table provided:

Dcsignation: Indicate t he appropriate u se designation for each p ond [ Treatment (T),

Disposal (D), Containment (C), or Evaporation (E)]

Discharge Point: If a discharge occurs from the Impoundments, designate the outfall associated with the impoundment.

Liner I nformation: If the impoundments are lined to comply with specifications outlined for t) a c ompacted clay liner (C), 2) an in-situ clay l iner (I), or 3) a synthetic/plastic/rubber liner (S), indicate the liner type with the appropriate letter designation (see instructions for further detail on liner specifications). If not, provide a reference to the attachment that provides a description of the alternate liner and any additional technical information necessary for an evaluation.

Dimensions: Provide t he dimensions(s), f reeboard, surface area, an d storage volume capacity of the impoundments. For impoundments with irregular shapes, submit surface area (instead of length an d width), the average depth, an d the maximum depth b elow natural ground level.

TCEQ-1 0055 (0511612012) Industrial Wastewater Permit Application Technical Report Page 3 of 66

Attachment NOC-AE-14003142 Page 30 of 155 Pond# 1 Pond# 2 Pond J Pond# 4 Pond# 6 Designation (T) (D) (C) or (E) T T T T Discharge Point j.

Outfall Number 501 501 101 001 none Liner Information Liner Type (C) (I) or (S) reinforce concrete reinforce concrete reinforce concrete soil and concrete none Alt. Liner Attachment Reference n/a n/a n/a n/a n/a Dimensions Length (feet) 100 ft 25 ft 136 ft .nia ft 150,ft Width (feet) 5o0 ft 25 ft 42 ft n/a ft 70 ft Depth from Water Surface 17.5 ft 13.3 ft 10 ft 20 ft 4 ft Depth from Nat. Ground Level .avg 0 max o avg oymax o2avg omax __o avg. o max 0 avg -2Lmax Freeboard (feet) '0 ft >2 ft >2 ft 2, ft '2 ft Surface Area (acres) o.io acres O.Olacres 0.13 acres 7,000acres 024 acres Storage Capacity (gallons) 1,000.000 gal 50,000 gal 600,000 gal " 6.6e0 gal 31.4,160 gal Pond # P_

ond# Pond# Pond## Pond#

-Designation  !***"

(T) (D) (C) or (E) C Discharge Point Outfall Number None Liner Informati-on-Liner Type (C) (I) or (S) soil and concrete Alt. Liner Attachment Reference n/a Dimensions Length (feet) .ft Width (feet) . 1,0oo ft .ft _ .ft ft ft Depth from Water Surface 8 ft ft ft _ ft ft Depth from Nat. Ground Level (avg/max) (feet) 0 . 0 I .I .

Freeboard (feet) '2 ft ft _ _ft _ ft ft Surface Area (acres) 47 acres acres _ acres 'acres .acres Storage Capacity (gallons) 1.3ea gal gal _ gal __ . gal gal TCEQ-10055 (05/15/2012) Industrial Wastewater Permit Application Technical Report Page 4 of 66

Attachment NOC-AE-14003142 Page 31 of 155 THE FO LLOWING I TEMS A RE R EQUIRED 0 NLY FO R N EW 0 R PR OPOSED IMPOUNDMENTS.

b. Indicate by a check mark if any of the following data was provided with the application:

Li Synthetic/plastic/rubber liner data LIIn-situ clay liner data Not Applicable Attachment #:_

c. Are there any leak detection systems or ground water monitoring wells in place or planned? Li Yes ni No Not Applicable Li If yes, indicate by a check mark that a separate attachment was provided with the leak detection system information for each pond and/or gr ound water monitoring well data.

Attachment #:

d. Is t he b ottom of the p ond a bove t he s easonal high water t able in t he shallowest water bearing zone?

Li Yes Li No Not Applicable Li If no, indicate by a check m ark that additional information was provided describing the depth of the seasonal high water table in the shallowest water bearing zone in relation to the depth of the bottom of the new or proposed impoundment and how this may or may not impact groundwater.

e. Indicate by a check mark that the following information was provided: Not Applicable L] A USGS quadrangle map or a color copy of original quality and scale which accurately locates and identifies water supply wells and/or monitor wells within 1/2 mile radius of the impoundments.

Li Copies of State Water Well Reports (driller's logs, completion data), and data on depths to g round water for water supply w ells in cluding a d escription o f how t he d epths t o ground water were obtained.

For TLAP permit applications: Not Applicable Li Indicate by a check mark t hat t he new or proposed impoundment(s) and the land application disposal area are located in the same general area and the information for this item is provided in Worksheet 3.0 (item 8).

Not Applicable

f. i- Indicate by a check mark id any data was provided with the application pertaining to the ground water, soils, geology, etc. used to assess the potential for migration of wastes from the impoundments and/or the potential for contamination of ground water or surface water.

Complete the following tables to describe the location and wastewater discharge or disposal operations for each outfall for discharge operations and for each point of disposal for TLAP operations.

For TLAP permit applications: Indicate the disposal method and each individual lirigation area (i), evaporation pond ( E), or subsurface drainage system (S) by providing the appropriate letter designation for the disposal method followed by a numerical designation for each disposal area (e.g. evaporation pond, application area) in the space provided for "Outfall" designation e.g. "E'" for ev oration pond 1 "12" for irrigation area No. 2, etc.).

TCEO-. 0055 (05A/517012) Industrial Wasttegater Permit Application Technical Report Page of 66

Attachment NOC-AE-14003142 Page 32 of 155 OUTFALL: 001

- Latitude . ' -Longitude*- Location Des.riptloh 8 44 96 00 .02 At a point in the blowdown line prior to entering the

Pirmitt*d*iow (MGD) Pirposed Fl",op(MD), Colorado River Dly Avg Dly MaVix. Dly Avg, -fy 3/4 31schar ge;I.tration 144 200 144 200 ** (hrs./day) ** (days/mo.) **_(mo./year)

X PumpedGravlty Measurement Device: Estimate X Intermittent _ Seasonal Continuous ting W4te0trAfis:-

..h..... -Volme 6 (MOD) Oz/f to'ta low Recirculated cooling water n/a** n/a**

Cooling reservoir blowdown Previously monitored effluent Stormwater Makeup water from the Colorado River Uncontaminated groundwater

  • At spillway. At blowdown at the river: 28' 44' 46" N,96' 00' 02" W

"*Therehas been no discharge from the outfall since March 4, 1997 OUTFALL: 002 La-tteUl.et  :. Location Doscription ,

468I 29 95 II 59 II 53 Prior to entering the plant drainage ditch PemtePoG) Proposed, IIW o.(M.Gb) vg Pi Max Dy IJyAg. -D~Ma t se harge burat onj n/a n/a n/a n/a n/a (hrs./day) !la (days/mo.) /a (nmo./year)

Pumped _L Gravity Measurement Device: estimate X Intermittent -Seasonal _ Continuous Reservoir relief well effluent (wells 1-125) Intermittent Demlneralized water from instrumentation Intermittent t *11*

p *

.11.

TCEQ-1 0055 (05/15/2012) Industrial Wastewater Permit Application Technical Report Page 6 of 66

Attachment NOC-AE-14003142 Page 33 of 155 OUTFALL: 003 Latituide'. Longf1tude Lorato ecrption 28 44 49 700 96 J40 At the discharge of flowing relief wells prior to mixing 1Permiitted FloW.(MGi) ooe P Wl- (MGO with the West Branch of Colorado River Ply Ag pDly Max. . .. ly"Av .., D1miD Max , . -.. bscharge 0 a d i ratlon n/a n/a n/a n/a (hrs./day) (days/mo.) .. (mo.Iyear)

Pumped Gravity Measurement Device: Estmlate X Intermittent -Seasonal Continuous Cnrbuting Wý~testrqamn . Vo GeMD) *Of Total Co.

Reservoir Relief Well effluent (wells 138-195) Intermittent 100 OUTFALL: 004 Latitudle, Longitude Location ýDeicri ption 28 44 ThiT IIEEgate Permnitte".d :FloW"(kO) 57 96 01 Prposed Flow (MGD)-

03 Ata point inthe MCR Spillway Channel after commingling of spillway leakage and relief well water, and prior to mixing with other waters i~li~g.DbiMa yDAvg, - .~ i~ak Kqshag urat~ion j n/a n/a n/a n/a , _ _(hrs,/day) . (days/mo.) .(mo./year)

Pumped X Gravity Measurement Device: Estimate Xintermittent -Seasonal __Continuous Rebutlng Relief Well effMODuent(well Flow Reservoir Relief Well effluent (wells 196-268) Intermittent 100 ii. a 4'

41 ii 4'

r II JI TCEQ-1 0055 (05/15/2012) Industrial Wastewater Permit Application Technical Report Page 7 of 66

Attachment NOC-AE-14003142 Page 34 of 155 OUTFALL: 005 Latitude Longitud6'.-'.'". Locat.i. Descr.ptlon"-

28 44 32 96 02 4 At the discharge of flowing relief wells, prior to mixing i'trmltteddFoib MG6). Proposed i low (!GiiDGt) with the East Fork Little Robbins Slough D~y ~yAg Dl AgMax OlyMax isc ~baeDuration n/a n/a n/a n/a _ (hrs./day) _ (days/mo.) _ (mo./year)

Pumped X Gravity Measurement Device: Estimate X Intermittent -seasonal ___Continuous Wate RontaibrtI re aief Wele .nttal Vowele (MG64) F Reservoir Relief Well effluent (wells 269-483) Intermittent 100 It it It It tI II

.11 ii OUTFALL: 006 Latitud ~ Longitude;:.. .ocapn-,-

14l I~'~r~m~!t~ted M1 31 _96 03I dFl* (MGD)ji 36 At the discharge of flowing relief wells, prior to mixing with Little Robbins Slough Dl~v ~l;a)< blý- lMax ishrbutdn n/a n/a n/a n/a (hrs./day) (days/mo.) ,(mo./year)

-Pumped X Gravity Measurement Device: Estimate , X Intermittent ____Seasonal ____Continuous

.' iii,; .-.. ..on

. V ",.".
...'.,.,'...

""'. i n e M b".. ., ". ,T*:.'lo ,>

Reservoir Relief Well effluent (wells 483-670) Intermittent 100

-e a

-ft It

-t It II H

-e II - I TCEQ-10055 (0511612012) Industrial Wastewater Permit Application Technical Report Page 7b of 66

Attachment NOC-AE-14003142 Page 35 of 155 OUTFALL: 101

.Lattude - ongltude' Location Description 2Where low volume waste sources commingled with previously monitored

l i .  ; effluents are discharged from the neutralization beslns prior to mixing with other Permitted Flodw (MGD) Proposed lF1oW (MGO) waste stream DyAvg OlyMax' A Dly Max on n/a n/a n/a n/a n/a_ (hrs./day) n/a (days/mo.) n/a (mo,/year)

X Pumped -Gravity Measurement Device: totalizer X Intermittent Seasonal Continuous t at~ras Volume (MOP)  % ifll No1W Low volume waste sources commingled with 0.25** 100 previously monitored effluents from the metal cleaning waste system discharge Stormwater

  • At discharge into the MCR
    • Total outfall flow, average Sep 12 - Apr 14 OUTFALL: 201

-Latitude'I -Lngtud.* .ILocatfon Descrfiiption 28 47 3 96 03 07 Where low volume waste sources are discharged from the oily waste

.( GD) treatment system prior to mixing with any other waste stream

-Permtited FloW ropose d F'V(M D 9~g t)ya D~Avg Diy Max ishageJuat na n/a n/a n/a fl/a (r.dy a (days/mo.) .2/a (mo./year

~.Pumped_ Gravity Measurement Device:_totalizer X Intermittent ____,Seasonal ___Continuous CotiuigWasteitraams:s- Volm I MD OA6hf Toailo Low volume waste sources from the oily waste O.019** 100 treatment system_________ _________

Stormwater

  • At discharge into theMCR _________
    • Total outfall flow, average Sep 12 - Apr 14 TCEQ-1 0055 (05/15/2012) Industrial Wastewater Permit Application Technical Reportg Page 7c of 66

Attachment NOC-AE-14003142 Page 36 of 155 OUTFALL: 401

- Latltude* Longltude' Locatloh besSrlotion 28 47"' 35 ""96""-03j ý7 At discharge from the sewage treatment plant (West Sanitary Waste

ýWtted Flow (MGD)

P..a.i Proposed Flow (MGD) Treatment System) prior to mixing with any other waste stream Oly AV g Dly Max Dly AVO PlMY rpchrx D ation, n/a n/a n/a n/a n/a (hrs,/day) n/a (days/mo.) n/a (mo./year)

X pumpedGravlty Measurement.Device: ultrasonic X Intermittent __Seasonal Continuous Treated sanitary sewage commingled with car 0.021* 100 wash water and air conditioning condensate Stormwater

  • At discharge into the MCR
    • Total outfall flow, average Sep 12- Apr 14 OUTFALL: 501 Latltucie* Longitude$'.. Lo'batidoh bes;rp n, 28 47 39 96 02 52 Where metal cleaning wastes are discharged prior to
.:r*. d*:Fl.O. G*I'o proposed Flow(MGD) mixing with any other waste stream

~O~~v~ WyMa Wyvg JliMax .> Diýcage Durftnori, n/a n/a n/a n/a n/a (hrs./day) n/a (days/mo.) 2/a (mo,/year)

X PumpedGravlty Measurement Device: estimate X Intermittent ___Seasonal Continuous Cd.-r ,-t..ri -. .u.ti.ng 777 7 7 W t :-: .*..e..:..*.-.'..,:,- -;. .. :*...*

.. *-*.\..*.,...  ; . -...V GD .....

of O ai~ W Metal cleaning waste n/a** R/a**

Stormwater

  • Prior to mixing with Outfall_101

"*There has been no discharge from this outfall since Dec 1992 TCEQ-1 0055 (05/15/2012) Industrial Wastewater Permit Application Technical Report Page 7d of 66

Attachment NOC-AE-14003142 Page 37 of 155 OUTFALL: 601 Latitude " Longitude  : Location.Descriptnon 28 I47 I15 96 02 [10 At discharge from the sewage treatment plant (Training Sanitary

.eritt..ed"low."(MD)i P.rop, d! FlOw (M".. Waste Treatment Facility) prior to mixing with any other waste stream Diy.:0'j bIlM'ax:'by'i~

, D OyWMax Dilscharge'ltiral n/a n/a n/a n/a rna (hrs./day) n/a (days/mo.) _.a_(mo./year)

X Pumped Gravity Measurement Device: ultrasonic - X Intermittent _ Seasonal _ Continuous Contribuit ing ast btr~ams - Vollumed(MG13 .13) TotalF oW.

To Treated sanitary sewage commingled with air 0.018"* 100 conditioning condensate and HVAC cooling tower blowdown Stormwater

  • At discharge into the MCR
    • Total outfall flow, average Sep 12 - Apr 14 OUTFALL:

Latitude Longitude .LctnDeriion el Iow GO) Proposed Flow (MGD)

I'y Avg Dly Max D!yAV9j  :~Max~ i'~~i~Drtion' (hrs./day) (days/mo.) _.(mo./year)

- Pumped Gravity Measurement Device:_, Intermittent -Seasonal ____continuous Contributing Wastestreams: -oiu i' MGb) . of iofM :7?'

r It II ii

41. 41 it. II L .41 TCEQ-1 0055 (05/15/2012) Industrial Wastewater Permit Application Technical Report Page 7e of 66

Attachment NOC-AE-14003142 Page 38 of 155

a. Does y our facility use any coolingtowers or boilers that discharge blowdown or other wastestreams to the outfall(s)? ELI Yes El No
b. Does your facility discharge once-through cooling water to the outfall(s)? LiYes FII No
c. If yes to either item a or b, indicate with a check mark that the appropriate MSDS with the following information for each chemical additive was submitted with the application.

71 Manufacturers Product Identification Number.

7] Product use. (e.g., biocide, fungicide, corrosion inhibitor, etc.)

P1 Chemical Composition including Chemical Abstracts System (CAS) number for each ingredient.

LI Classify product as non-persistent, persistent, or bloaccumulative.

H Product or active ingredient half-life.

71 Frequency of product use (e.g., 2 hr/day once every two weeks).

RV Product toxicity data specific to fish and aquatic invertebrate organisms.

71 Concentration of whole product in wastestream (if above item is for whole product)

E] Concentration of active ingredient in wastestream (if above item is for active ingredient)

Please provide a summary of this information in a ddition to the submittal o f the M SDS for each specific w astestream an d the associated ch emical a dditives and specify which outfalls are affected.

Attachment:

I

d. Cooling Towers and Boilers Number of Units Daily Avg. Blowdown Dally Max Blowdown Cooling Towers 1 cooling towers Dally Avg: 7,200 gallons/day Dally Max: 17,280 gallons/day Boilers 1 boilers Daily Avg:
  • gallons/day Dally Max:
  • gallons/day

.*4,022 gpd.*fo-a,,p rox matl d¥s e1 ear Are there any existing or proposed outfalls which discharge stormwater runoff commingled with other wastestreams?

[0 Yes FH No. If yes, provide the following information. If no, proceed to Item No. 7.

a. Provide a brief n arrative description of the industrial processes and a ctivities t hat occur outdoors or in some manner that may result in exposure of the materials to precipitation or runoff in areas where runoff is generated.

Storm water drainage from production and non-production areas Is discharged through permitted outfalls or under the TPDES Storm Water General Permit. For production areas, at least the first flush of stormwater runoff from SPOC sources and production equipment areas is collected and treated by the Oily Waste Treatment Systems (Outfall 201). Secondary containment is provided for chemical and other storage tank areas.

TCEQ-10055 (0511612012) Industrial Wastewater Permit Application Technical Report Page 8 of 66

Attachment NOC-AE-14003142 Page 39 of 155 D7 EOXM4RTICS SWAGE~ SWAXf MIIGE A 4D/RSPAT? MANA1M~

'7 ANN PVSA(~

SEPTAa~4~

V, WAGPA

a. Please check the appropriate method(s) of domestic sewage and domestic sewage sludge treatment/disposal and complete Attachment F if directed.

[] Domestic sewage is not generated on-site. PROCEED TO ITEM NO. 8.

- Both do mestic and industrial treatment sludge ARE commingled prior to use or disposal. PROCEED TO ITEM NO. 8.

121 Industrial wastewater and domestic sewage are treated separately and the respective sludge IS NOT commingled prior to sludge use or disposal COMPLETE WORKSHEET 5.0 OF THIS APPLICATION.

[] If your facility is a POTW, COMPLETE WORKSHEET 5.0 OF THIS APPLICATION.

F] Facility is connected t o a wastewater treatment plant permitted t o receive domestic sewage, or the domestic sewage is transported off-site to a permitted facility for treatment and/or disposal. COMPLETE ITEM NO. 7.11.

n Domestic sewage is disposed of by an on-site septic tank. COMPLETE ITEM 7.B.

T- Other: Please provide a detailed description below.

b. Provide t he name and TC EQ, NPDES, and/or TPDES Permit N o. of t he waste disposal facility which receives the domestic sewage/septage. If hauled by motorized vehicle, provide the name and TCEQ Registration No. of the hauler.

N/A Is the p ermittee currently required t o meet any implementation schedule for compliance or enforcement? E] Yes W] No If yes, provide a brief summary of the requirements and a status update.

TCEQ-10055 (05115/2012) Industrial Wastewater Permit Application Technical Report Page 1)of 66

Attachment NOC-AE-14003142 Page 40 of 155 Have any biological tests for acute or chronic toxicity been made on any of your discharges or.

on a receiving water in relation to your discharge within the last three (3) years?

El Yes l] No If yes, identify the tests and describe their purposes below. Please attach a copy of all tests performed that have not been previously sent to the TCEQ and/or EPA.

There has been no discharge via Outfall 001 since 1997. The facility will perform the required testing when discharges occur.

P ~~a YOPSIETfI(1-ftcii,V.A%~~ pge )

Do you receive wastes from off-site sources for treatment in your facility, disposal on-site via land. application, and/or discharge via a permitted outfall El Yes V No If no, proceed to Item No. ii. If yes, proceed as directed.

a. Indicate with a check mark that a detailed attachment with the following information was provided with the application:

F-1 List of wastes received Identified sources of wastes received 8 -- Characterization of wastes receivedH Volumes of each waste received Info. on compatibility with on-site wastes Name and addresses of generators Description of the relationship of waste source(s) with your facility's activities.

Attachlnent:

b. Is wastewater from a TCEQ, NPDES, and/or TPDES permitted facility commingled with your wastewater after your final treatment and prior to discharge via your final outfall/point of disposal? E] Yes n- No If yes, provide the name, address, and TCEQ, NPDES, and/or TPDES permit number of the co ntributing facility an d a copy of any agreements an d/or contracts r elating t o t his activity.
c. Is your facility a Publicly Owned Treatment Works (POTW) that accepts process wastewater from any Significant Industrial User (SIU) and has or is required to have an approved pretreatment program under the NPDES/TPDES program? El Yes 11 No If yes, complete Worksheet 6.o of this application.

Are radioactive materials mined, used, stored, or processed at this facility? 2 Yes [] No If yes, Provide alist of the materials and the r esults of one analysis of your effluent in picocuries per liter (pCi/L) for all radioactive parameters which may be present.

Radioactive Materials Conc. (pCi/L)

Nuclear fuel (CAS no. 7440-61-1) --- *

  • There has been no discharge via Outfall 001 since 1997.

TCEQ-10055 (05/10/2012) Industrial Wastewater Permit Application Technical Report Page 10 of 66

Attachment NOC-AE-14003142 Page 41 of 155 THE FO LLOWING ITEMS ARE ONLY REQUIRED FOR EXISTING PERMITTED FACILITIES.

Are you requesting a major amendment of an existing permit? 71 Yes F] No If yes, list each specific request and provide discussion on the scope of any requested permit changes.

See Attachment J If necessary, provide supplemental information or additional data that will support the request.

Are you requesting any minor modifications to the permit? RV Yes E- No Note: see the instructions for an exclusive list of changes considered as minor modifications.

If yes, list and discuss the requested changes.

Please revise the definition for "total residual chlorine" provided In Other Requirement No. 4 to be consistent with the current definition for "total residual chlorine" in 40 CFR 423 that reads as follows:

"The term total residual chlorine (or total residual oxidants for Intake water with bromides) means the value obtained using any of the "chlorine-total residual" methods in Table IB in 40 CFR 136.3(a), or other methods approved by the permitting authority."

Are you requesting any minor amendments to the permit? ___Yes , No If yes, list and discuss the requested changes.

TCEQ-1 0055 (05115/2012) IndustrIal Wastewater Permit Application Technical Report Page I1Iof 66

Attachment NOC-AE-14003142 Page 42 of 155 WORKSHEETS TO THE INDUSTRIAL WASTEWATER PERMIT APPLICATION TECHNICAL REPORT Please review the worksheet requirements in the instructions and indicate by checking either yes or no which worksheets are required, completed, and submitted with the technical report.

Worksheets that are not applicable do not need to be submitted with the technical report.

COMPLETED AND SUMI'JTED WITF

,WORKSHJEET ITHET CHNIt RIEPORT:-

YES NO 1.0: EPA EFFLUENT CATEGORICAL GUIDELINES []1 F]1 2.0: POLLUTANT ANALYSES REQUIREMENTS [ElF 3.0: LAND DISPOSAL OF EFFLUENT[7[]

3-1 SURFACE LAND DISPOSAL OF EFFLUENT [ 7 3.2: SUBSURFACE LAND DISPOSAL OF EFFLUENT [I] R(]

3-3 SUBSURFACE AREA DRIP DISPERSAL SYSTEM LAND E7] o7 DISPOSAL OF EFFLUENT 4.0: RECEIVING WATERS [7 F]

4.1: STREAM PHYSICAL CHARACTERISTICS WORKSHEET Di 7]

5.0: SEWAGE SLUDGE MANAGEMENT AND DISPOSAL [71 [E]

6.0: INDUSTRIAL WASTE CONTRIBUTION [7 [7 7.0: STORM WATER RUNOFF Z~7 El 8.o: AQUACULTURE[] 7 9.0: CLASS V INJECTION WELL I]7 10.0: QUARRIES IN THE JOHN GRAVES SCENIC RIVERWAY 7 7 TCEQ-10055 (05/15/2012) Industrial Wastewater Permit Application Technical Report Page 12 of 66

Attachment NOC-AE-14003142 Page 43 of 155 Worksheet 1.0 EPA Effluent Categorical Guidelines

Attachment NOC-AE-14003142 Page 44 of 155 WORKSHEET 1.o EPA EFFLUENT CATEGORICAL GUIDELINES REQUIRED FOR ALL APPLICATIONS FOR TPDES PERMITS FOR DISCHARGES OF WASTEWATERS SUBJECT TO EPA EFFLUENT LIMITATION GUIDELINES.

Is your facility subject to any of the 40 CFR effluent guidelines outlined in Table I?

E-IYes n.No If yes, provide the appropriate information in the table below. I f no, this worksheet is not required.

IndustryCFR Steam Electric Generating Station 423

a. Production data: Provide the appropriate data for effluent guidelines with production based effluent limitations.

Sub:ategory .. D... ... Units Uc....

-i::;,** -: i QuanUttY/Day jQuantityiDa.,.*

N/A

b. Organic Chemicals, P lastics, and S ynthetic Fibers Ma nufacturing Data (40 CFR Part 414): Provide each appropriate subpart and the percent of total production.

Also provide the appropriate data for metal bearing wastestreams as required in 40 CFR Part 414, Appendices A and B.

N0Aof totallApendixA andB Suctgr productio.iMtl rcs NIA _ _ _ _ _ _ _ _

TCEQ-10055 (05/15/2012) Industrial Wastewater Permit Application Technical Report Page 13 of 66

Attachment NOC-AE-14003142 Page 45 of 155

c. Refineries (40 CFR Part 419): Provide the applicable subcategory and a brief justification for each.

N/A 0OCES NOW~&ESWS. M6~d X~~l6S eaire~dw fpo See Flow diagrams, Attachment H to~V1fen e- 9ti~K~ "p.-t t pg4~

nea .r S Process . EPA Guidleline Date Process/

PIart Subp.art Construction.

P.olmmenced Units I and 2 423 N/A 1975 Units 3 and 4 423. N/A Near future TCEQ-1 0055 (05116/2012) Industrial Wastewater Permit Application Technical Report Page 14 of 66

Attachment NOC-AE-14003142 Page 46 of 155 Worksheet 2.0 Pollutant Analyses Requirements

Attachment NOC-AE-14003142 Page 47 of 155 Worksheet 2.0 Notes and Additional Information Outfall 001: There has not been a discharge from Outfall 001 since 1997, therefore, the required effluent samples for the application could not be collected.

STP will collect the required samples for the application upon the next available discharge via Outfall 001 and submit the results to the TCEQ for review.

Outfalls 002-006: Effluent data is currently being collected by the facility for these outfalls. The sample result will be submitted at a later date under separate cover.

Attachment NOC-AE-14003142 Page 48 of 155 WORKSHEET 2.0 POLLUTANT ANALYSES REQUIREMENTS

  • there has not been a discharge via Outfall 001 since 1997.

REQUIRED FOR APPLICATIONS SUBMITTED FOR A TPDES PERMIT. NOT REQUIRED FOR APPLICATIONS FOR A PERMIT TO DISPOSE OF ALL WASTEWATER BY LAND DISPOSAL OR FOR DISCHARGES SOLELY OF STORM-WATER RUNOFF. (General Requirements: Instructions, Pages 49-51)

'lP6Ilutarnts iV>!* LD IC

!Outfall Nt."'P0*l- 0 .. *Sam~p,:.

G .i':*:i!,~~i.*~:.*i.EfU

-::i,*:.:-'ii:i;  :}Samp (tc6n e p.,

  • . !iSam tain( gl.: >.Average~
  • _Sarnp.,:i* :*i:*i::'.i-BOD.(5-day) .....

CBOD (5-day)

Chemical Oxygen Demand Total Organic Carbon r_.,, _r_

Dissolved Oxygen Ammonia Nitrogen Total Suspended Solids Nitrate Nitrogen .

Total Organic Nitrogen Total Phosphorus Oil and Grease Total Residual Chlorine Total Dissolved Solids Sulfate Chloride Fluoride IiiIl Temperature (OF) pH (Standard Units; min/max)_

  • fl tC',,r ;n (gI~.. . , . ",. MA.

Total Aluminum 30 Total Antimony 30 Total Arsenic 10 Total Barium 10 Total Beryllium 5 Total* Cadmium 1 Total Chromium 10 Trivalent Chromium . N/A Hexavalent Chromilum 10 Total.Copper 10 Cyanide ,20 Total Lead .5 Total Mercury 0.2 Total Nickel 10 Total Selenium 10 Total Silver 2.0 Total Thallium _10 Total Zinc 5 TCEQ-10055 (05/16/2012) Industrial Wastewater Permit Application Technical Report Page 15 of 66

Attachment NOC-AE-14003142 Page 49 of 155 Complete table required for all external outfalls which discharge process wastewater. Partial table required for all external outfalls with n onprocess wastewater discharges. Stormwater runoff discharges commingled with other wastestreams shall complete the table as instructed (Instructions, Pages 49-51). ,

There has not been a discharge via Outfall 001 since 1997.

Dutfall No.: ncC IO fletCnetatoi.pI)(1

.Pol.utan /....SAMp':. 2 Samp 3.. S.h.S 4 ".Ayerage M.AL (Pg/I.

Benzene 10 Benzidine 50 Benzo(a)anthracene _10 Benzo(a)pyrene 10 Carbon Tetrachloride 10 Chlorobenzene 10 Chloroform 10 Chrysene 10 Cresols (*2)

Dibromochloromethane _10 1,2-Dibromoethane ý2 1,4-Dichloro benzene 10 1,2:.Dlchloroethane 1G0 1,1-Diohloroethylene 10 Fluoride .600 Hexachlorobenzene 10 Hexachlorobutadlene 10 Hexachloroethane 20 Methyl Ethyl Ketone .50 Nitrobenzene 10 n-Nitrosodlethylamlne 20 n-Nltroso-di-n-Butylamlne 20 PCB's, Total (*3) 1 Pentachlorobenzene 20 Pentachlorophenol 50 Phenanthrene _10 Pyrldlne 20 1,2,4,5-Tetrachlorobenzene 20 Tetrachloroethylene 10 Trichloroethylene 10 1,1,1.-Trlchloroethane "_10 2,4,6-Trlchlorophenol 50 TTHM (Total Trihalmethanes) 10 Vinyl Chloride 10

(*1) Indicates units if different from pg/l.

(*2) MAL's for Cresols: p-Chloro-m-Creso 10 pg/1; 4,6-Dinitro-o-Cresol 50 pg/i; p-Cresol o0pg/l.

(*3) Total PCB-1242, PCB-1254, PCB-1221, PCB-1232, PCB-1248, PCB-126o, PCB-ioi6.

TCEQ-1 0055 (05/16/2012) Industrial Wastewater Permit Application Technical Report Page 16 of 66

Attachment NOC-AE-14003142 Page 50 of 155

a. LABORATORY ACCREDITATION:

Effective July 1, 2oo8, all laboratory tests performed must meet the requirements of 3o TAC Chapter 25, Environmental Testing Laboratory Accreditation and Certification with the following general exemptions:

i. The laboratory is an in-house laboratory and is:
1. periodically inspected by the TCEQ; or
2. located in another state and is accredited or inspected by that state; or
3. performing work for another company with a unit located in the same site; or
4. performing pro bono work for a governmental agency or charitable organization.

ii. The laboratory is accredited under federal law.

iii. The data are needed for emergency-response activities, and a laboratory accredited under the Texas Laboratory Accreditation Program is not available.

iv. The laboratory supplies data for which the TCEQ does not offer accreditation. I The applicant should review 3 o T AC Chapter 2 5 for specific requirements. The following certification statement shall be signed and submitted with very application. See Instructions, Page 30, for a list of designated representatives who may sign the certification.

I, Michael P. Murray certify that all laboratory tests submittedwith this application meet the requirements of 3o TAC Chapter 25, Environmental Testing Laboratory Accreditation and Certification.

Partial table (only those pollutants which are required by the conditions specified for each outfall where the pollutant is believed to be present) required for each external outfall where the source is identified. Not required for internal outfalls.* (Instructions, Page 51)

a. TRIBUTYLTIN:

Is your facility or will your proposed facility be an industrial/commercial facility which directly disposes of wastewater from the types of operations listed below or a domestic facility which receive wastewater from the types of industrial/commercial operations listed below? DI Yes 0 No If yes, Indicate with a check mark all of the following criteria which apply and provide the appropriate testing results in the table below.

M anufacturers and formulators of tributyltin or related compounds.

Painting of ships, boats and marine structures.

H Lj Ship and boat building and repairing, Ship and boat cleaning, salvage, wrecldng and scaling.

Operation and maintenance of marine cargo handling facilities and marinas Facilities engaged in wood preserving LI Any other industrial/commercial facility for which tributyltin is known to be present, or for which there is any reason to believe that tributyltin may be present in the effluent.

TCEQ-1 0055 (05/15/2012) Industrial Wastewater Permit Application Technical Report Page 17 of 66

Attachment NOC-AE-14003142 Page 51 of 155

b. ENTEROCOCCI Does your facility or will your proposed facility discharge directly into saltwater receiving waters and:

Enterococci bacteria Is expected to be present?

Z]Yes 0INo Is domestic wastewater discharged?

W Yes M-No If yes to either question, provide the appropriate testing results in the table below.

c. E. coli Does your facility or will your proposed facility discharge directly into fresh water receiving waters and:

ElU~l] acteria is expected to be present?

VIjYes L1No Is domestic wastewater discharged?

ED Yes [Z No If yes to either question, provide the appropriate testing results in the table below.

TABLUE A.:::....

Outfall No.: oC oG Effluent Concentration Pollutants Samp. 1 Samp. 2 Samp. 3 Samp. 4 Averagc MAL Tributyltin (gg/1) 0.010 Enterococci (CFU or MPN/1oo ml) N/A E. coli (CFU or MPN/ioo ml) N/A Complete table r equired f or all external outfalls which discharge process wastewater and other wastewaters, which way contain pesticides or herbicides, from a facility which manufactures or formulates pesticides or herbicides. Not required for internal outfalls.

Does your facility manufacture or formulate pesticides or herbicides? E] Yes [Z No If yes, provide the appropriate testing results.

"CEQ-10056 (05115/2012) Industrial Wastewater Permit Application Technical Report Page 18 of 66

Attachment NOC-AE-14003142 Page 52 of 155

,ý.tr f-.' 01) *)

OIitfall No.ý ZCE ~ D

~; f~ihQfoMaln4I EX ...

A Pdltht.', Saffib.rI SaMp. 2; Ship. 3 Sanip. 4.A:. ' (091I)'

Beta-hexachlorocyclohexane 0.05 Carbaryl 5 Chlordane 0.15 Chlorpyrifos 0.05 2,4-D 10 Danitol 4,4-DDD 0.1 4,4'-DDE 0.1 4,4'-DDT 0.1 Demeton 0.2 Diazlnon 0.6 Dloofol 20 Dieldrin 0.1 Diuron 0.09 Endosulfan I (alpha) 0.1 Endosulfan II (beta) 0.1 Endosulfan Sulfate 0.1 Endrln 0.1 Gamma - Hexachlorocyolohexane (Lindane) 0,05 Guthlon 0.10 Heptachlor 0.05 Heptachlor Epoxide 1,0 Hexachlorophene 10 Malathlon 0.10 Methoxychlor 2.0 Mirex 0.2 Parathion 0.1 Toxaphene 5 2,4,5-TP (SIlvex) 2

  • Indicate trnits if different from mg/L.

TCEQ-10055 (05/15/2012) Industrial Wastewater Permit Application Technical Report Page 19 of 66

Attachment NOC-AE-14003142 Page 53 of 155 Complete table required for all external outfalls. Not required for internal outfalls.

(Instructions, Page 52)

OUtfaII No': nC oiG B616eIIVd b'ICOGn

- , , Verage Mtaxlrimum NOf oSafibe§ Bromide Color(PCU)

Nitrate-Nttrite(as N)

Sulfide(as S)

Sulfite(as SO3)

Surfactants Total Antimony Total Beryllium Total Boron Total Cobalt Total Iron Total Magnesium Total Molybdenum Total Manganese Total Thallium Total Tin Total Titanium TCEQ-10055. (05/15/2012) Industrial Wastewater PermIt Application Technical Report Page 20 of 66

Attachment NOC-AE-14003142 Page 54 of 155 Indicate with a check mark any of the industrial caategories applicable t o y our facility. If testing is required, indicate with a check mark in the box provided that the testing results for the appropriate parameters in Table B-7 a re p rovided with t he application. (Instructions, Page 52-53)

N/Ak,etl4~dle . CiA Volatile Acid Oase/Neutral Pesticides Adhesives and Sealants Yes [] Yes El Yes El No Aluminum Forming Yes El Yes ED Yes El No Auto and Other Laundries Yes El Yes E) Yes El Yes El Battery Manufacturing Yes E] No Yes El No Coal Mining No No No No Coll Coating Yes D Yes El Yes El No Copper Forming Yes C- Yes El Yes El No

__ Electric and Electronic Components Yes El Yes El Yes El Yes El Electroplating Yes Dl Yes El Yes El No Explosives Manufacturing No Yes El Yes El No Foundries Yes El Yes ED Yes El No Gum and Wood Chemicals

_____Subparts AB,C,E Yes El Yes El No No Subparts D,F Yes El Yes Ul Yes El No Inorganic Chemicals Yes [l Yes El Yes [ No Iron and Steel Manufacturing Yes El Yes El Yes El No Leather Tanning/Finishing Yes El Yes El Yes El No Mechanical Products Manufacturing Yes El Yes El Yes El No

__ Nonferrous Metals Mfg. Yes El Yes El Yes El Yes El Ore Mining(Subpart B) No Yes El No No Organic Chemicals, Plastics, and Synthetic Fibers Yes El Yea El Yes LJ Yes El Paint and Ink Formulation Yes El Yes El Yes El No Pesticides Yes El Yes El Yes El Yes D Petroleum Refining Yes El No No No Pharmaceutical Preparations Yes El Yes El Yes EL No Photographic Equipment and Supplies Yes El Yes El Yes El No Plastic and Synthetic Materials Manufacturing Yes El Yes El Yes El Yes El Plastic Processing Yes El No No No Porcelain Enameling No No No No Printing and Publishing Yes El Yes El Yes El Yes El

-Pulp and Paperboard Mills

___.Subparts A *E] Yes l *l Yes U

_ Subparts B, C, D, R

  • El Yes l *El *El

____Subparts F, G, H, 1, K, L, M. N,O, P Yes El Yes El

  • El
  • El Subparts E, Q, S, T Yes El Yes l *El Yes [

Subparts J, U YesEl Yes El Yes El

  • El

-Rubber Processing Yes El Yes El Yes El No Soap and Detergent Manufacturing Yes El Yes El Yes El No V Steam Electric Power Plants Yes El Yes El No No Textile Mills (Not Subpart C). Yes El Yes El Yes El No Timber Products Processing Yes El Yes El Yes El Yes El

  • Test if "believed present" TCEQ-10055 (05116/2012) Industrial Wastewater Permit Application Technical Report Page 21 of 66

Attachment NOC-AE-14003142 Page 55 of 155 Please complete as directed and only for those parameters specified in Table 6 Required for all external outfalls which contain process wastewater. N ot required for internal outfalls. Testing may be required for types of industry not specified in Table 6 for specific parameters if believed present (Instructions, Page 53).

TAIILE t

  • llll lrR ll
. ..****:.i,:::.H ll,llrl;" .. ..

... ..,.{. .,

. .,. :*'!,:r'* :*,:!'~ * : !,:

  • 7 *.::

., .:...i, .... ,. . .i .*ll * . , i .. il*]i ,.. ,... .. :...,,.

-*,* L' .vg.*.}

, ,* ~ * * . , W-w*

SS VOLATIlLE COMPOUNDS, ', ~pp Acrolein 50 Acrylonltrile 50 Benzene 10 Bromoform 10 Carbon Tetrachloride 10 Chlorobenzene 10 Chlorodibromomethane 10 Chloroethane 50 2-Chloroethylvinyl Ether 10 Chloroform 10 Dichlorobromomethane 10 1,1-Dlchloroethane 10 1,2-Dichloroethane 10 1,1-Dichloroethylene 10 1,2-Dichloropropane 10 1,3-Dlchloropropylene 10 Ethylbenzene 10 Methyl Bromide 50 Methyl Chloride 50 Methylene Chloride 20 1,1,2,2-Tetrachloroethane 10 Tetrachloroethylene 10 Toluene 10 1,2-Trans-Dlchloroethylene 10 1,11,11-TrIchloroethane 10 1,1,2-Trichloroethane 10 Trichloroethylene 10 Vinyl Chloride 10 TCEQ-1 0055 (05/16/2012) Industrial Wastewater Permit Application Technical Report Page 22 of 66

Attachment NOC-AE-14003142 Page 56 of 155 Effluent Concentration (pg/I)*

ACID COMPOUNDS S-!.*;- .,* ' -.

Average I-Samples Maximum V

MAL (pg/o) 2-Chlorophenol 10 2 ,4-Dlchlorophenol 10 2,4-Dimethylphenol 10 4,6-Dinltro-o-Cresol 50 2,4-Dinitrophenol 50 2-Nitrophenol 20 4-Nitrophenol 50 P-Chloro-m-Cresol 10 Pentalchlorophenol 50 Phenol 10 2,4,6-Trichlorophenol 10 BASEINEUTRAL COMPOUNDS Acenaphthene 10 Acenaphthylene 10 Anthracene 10 Benzldine 50 Benzo(a)Anthracene 10 Benzo(a)Pyrene 10 3,4-Benzofluoranthene 10 Benzo(ghl)Perylene 20 Benzo(k)Fluo.ranthene 10 Bis(2-Chloroethoxy) Me~thane 10 Bis(2-Chloroethyl)Eter .. 10 B.s(2-Chlorolsopropyl).Eth~er 10 Bis(2-Ethylhexyl)Phthlarte 1.0 4-Bromophenyl Phenyl Ether 10 Butylbenzyl Phthalate 10 2-chloronaphthalene 10 4-chorophenyl phenyl ether 10 Chrysene 10 Dlbenzo(a,h)Anthracene 20 1.,2-Dlchlorobenzene 10 1,3_.Dchlorbenzene 10 1,4-Dlchlorobenzene 10 3,3-Dlchlorobenzldine 50 Dl~ethyl Phthalate 110 Dlmethyl Phthalate 10 DI-n-Butyl Phthalate 10 2,4-Dlnitrotoluene 10 2,6-Dinltroluene 10 DI-n-Octyl Phthalate 10 TCEQ-1 0055 (05115/2012) Industrial Wastewater Permit Application Technical Report Page 23 of 66

Attachment NOC-AE-14003142 Page 57 of 155

  • , * ,,*,,* ,**.,*,*,{,,_*

,#*.  :. *. .*:,Efflue nt Concentration (pgll)* *:,i"!;:;.*'i:;!**  :

Pollutants Average Maximum !No. of Samples MAL (pg/I)

BASEINEUTRAL COMPOUNDS (cont.)  !***l**;*********-i;*LI **i ******;L**

NTi*:i *,,,';:****'.

1,2-Dlphenyl Hydrazine (as Azobenzene) 20 Fluoranthene 1'0 Fluorene 10 Hexachlarobenzene 10 Hexachlorobutadiene 10 Hexachlorocyclopentadlene 10 Hexachloroethane 20 Indeno(1,2,3-cd)pyrene 20 Isophorone 10 Naphthalene 10 Nitrobenzene 10 N-Nltrosodlmethylamlne 50 N-Nitrosodl-n-Propylamlne 20 N-Nitrosodiphenylamlne 20.

Phenanthrehe 10 Pyrene 10 1,2,4-Trichlorobe nzene 10 PESTICIDES Aldrin 0.05 alpha-BHC 0.05 beta-BHC 0.05 gamma-BHC 0.05 delta-BHC 0,05 Chlordane 0.15 4,4-DDT 0.1 4,4-DDE 0.1 Dleldrin 0.1 alpha-Endosulfan 0.1 beta-Endosulfan 0,1 Endosulfan Sulfate 0,1 Endrln 0.1 Endrln Aldehyde 0.1 Heptachlor 0.05 Heptachlor Epoxide PCB-1 264 1.0 PCB-1 221 1.0 PCB-1242 PCB-1 232 1,0 PCB-1248 1.0 PCB-1 260 1.0 PCB-1016 1.0 Toxaphene 5.0

....... ..... . .I, . .. .. . - .. . .. . . . . . .,M, , .

TCEQ-1 0055 (05/15/2012) Industrial Wastewater Permit Application Technical Report Page 24 of 66

Attachment NOC-AE-14003142 Page 58 of 155 8 TABL3 IS (MOXINS/ WOiUDS RA Please complete as directed. Not required for internal outfalls. (Instructions, Pages 53-54)

a. Are any of the following compounds manufactured and/or u sed in a process at t he facility? Fj Yes 0 No If yes, i ndicate with a ch eck mark the compound(s) which apply and provide a brief description of the conditions of its/their presence at the facility.

Ml 2,4,5-trichlorophenoxy acetic acid (2,4,5-T) CAS #93-76-5 E- 2-(2,4,5-trichlorophenoxy) propanoic acid (Silvex, 2,4,5-TP) CAS #93-72-1 n- 2-(2,4,5-trichlorophenoxy) ethyl 2,2-dichloropropionate (Erbon) CAS #136-25-4

[] o,o-dimethyl o-(2,4,5-trichlorophenyl) phosphorothioate (Ronnel) CAS #P-99-84-3 E] 2,4,5-trichlorophenol (TCP) CAS #95-95-4 E] Hexachlorophene (HCP) CAS #70-30-4

b. Do you know or have any reason to believe that 2,3,7,8 Te trachlorodibenzo-P-Dioxin (TCDD) or any congeners of TCDD may be present in your effluent? [] Yes [] No If yes, provide a brief description of the conditions for its presence.

C. If your responded yes to either item a or b, complete Table 8 as instructed.

VAB TE 8 Outfall No. -C [G ,wte. u:7

:EMIulvent Concentration EqivalV~ents Concelitratiori EqUlValentSt MAL (ppq)

_onip6Und QAýýrs~~(p) .. (PptM P? (ppt))

2,3,7,8-TCDD 1 10.0 1,2,3,7,8-PeCDD 0.5 50.0 2,3,7,8-HxCDDs 0.1 50.0 2,3,7,8-TCDF 0.1 10.0 1,2,3,7,8-PeCDF 0.05 50.0 2,3,4,7,8-PeCDF 0,5 50.0 2,3,7,8-HxCDFs 0.1 50.0 Total TCEQ-1 0055 (05115/2012) Industrial Wastewater Permit Application Technical Report Page 26 of 66

Attachment NOC-AE-14003142 Page 59 of 155

~9.J'flJE9HAAt S V1J STAN~ES:

Proceed complete as directed. Not required for internal outfalls. (Instructions, Pages 55)

a. Are there any pollutants listed In the instructions (page 55) believed present in the discharge?

LlYes INo

b. Are there pollutants listed in Item No. i.d. on Page No. i of this technical report which are believed present in the discharge and have not been analytically quantified elsewhere in this application?

[]Yes O7No If your responded yes to either item, complete Table 9 as instructed.

TALit CAS-N_________d_________

<~Arae0px~niiI 'N6.of, 1'Atialytio~I 1- 4 4

- I 4- 4 4 t .4- 4 .4 I *4-* .4 4-t +/- 4 +

TCEQ-1 0055 (05/1512012) Industrial Wastewater Permit Application Technical Report Page 26 of 66

Attachment NOC-AE-14003142 Page 60 of 155 Worksheet 4.0 Receiving Waters

Attachment NOC-AE-14003142 Page 61 of 155 WORKSHEET 4.0 RECEIVING WATERS THE FOLLOWING IS REQUIRED FOR ALL TPDES PERMIT APPLICATIONS Is t here a surface water intake for domestic drinking water supply I ocated within 5 (five) miles downstream from the point/proposed point of discharge?

ElYes WNo If yes, identify owner of the drinking water supply, the distance and direction to the Intake, and locate and identify the intake on the USGS map. Indicate by a check mark that the requested information is provided: D]

a. Width of the receiving water at the outfall? ~300 feet
b. Are there oyster reefs in the vicinity of the discharge? [] Yes [No If yes, Indicate approximate distance and direction from outfall(s):
c. Are there any sea grasses within the vicinity of the point of discharge?

D Yes []No If yes, provide the distance and direction to the grasses:

Is the discharge directly into (or within 300 feet of) a classified segment?

V Yes -No If yes , stop here. It is not necessary to complete items 4 and 5 and it is n ot necessary to complete Worksheet 2.1. If no, complete items 4 and 5.

Name of the immediate receiving waters:

a. Check the appropriate description of the receiving waters H Man-made Channel or Ditch EStream or creek n] Lake or Pond Surface area _ .acres Average depth of the entire water body - feet Average depth of water body within a 5oo-foot radius or the discharge point - feet E] Freshwater Swamp or Marsh Tidal Stream, Bayou, or Marsh Open Bay

[] Other:

If a man-made channel, ditch or stream was checked above, provide the following:

TCEQ-10055 (05/1612012) Industrial Wastewater Permit Application Technical Report Page 39 of 66

Attachment NOC-AE-14003142 Page 62 of 155

b. Check one of the following that best characterizes the area upstream of the discharge.

For new discharges, characterize the area downstream of the discharge (check one).

-' Intermittent (dry for at least one week during most years)

L] Intermittent with Perennial Pools (enduring p ools c ontaining s ufficlent habitat t o maintain significant aquatic life uses)

F] Perennial (normally flowing)

Check t he method used t o c haracterize t he a rea u pstream (or d ownstream for n ew dischargers):

FI USGS flow records DI personal observation LI historical observation by adjacent landowner(s)

[] others, specify:

C. List t he n ame(s) o f all p erennial streams t hat j oin t he r eceiving water within three miles downstream of the discharge point:

d. Do the receiving water characteristics change within three miles downstream of t he discharge? (e.g., natural or man-made dams, ponds, reservoirs, etc Dl Yes E]No If yes, discuss how:
e. Provide general obser vations of the water body during normal dry weather conditions:

Date and time of observation:

Was water body influenced by stormwater runoff during observations?

n Yes [-No

a. Is the receiving water upstream of the discharges or proposed discharge site influenced by (check as appropriate):

RI oil field activities LI urban runoff L-] agricultural runoff LI septic tanks E] upstream discharges LI others, specify below TCEQ-10055 (05/115/2012) Industrial Wastewater Permit Application Technical Report Page 40 of 66

Attachment NOC-AE-14003142 Page 63 of 155

b. Uses of water body observed or evidences of (check as appropriate):.

[ livestock watering El contact recreation ED irrigation withdrawal Li non contact recreation El fishing E- navigation El domestic water supply Li industrial water supply Ri picnic park activities El others, specify below

c. Check one of the following to best describe the aesthetics of the receiving water and the surrounding area:

LI Wilderness: outstanding natural beauty; usually wooded or unpastured area: water clarity exceptional Li Natural Area: trees and/or native vegetation common; some development evident (from fields, pastures,dwellings); water clarity discolored Li Common Setting: not offensive, developed but uncluttered; water may be colored or turbid Li Offensive: stream does not enhance aesthetics; cluttered; highly developed; dumping areas; water discolored TCEQ-10055 (0511512012) Industrial Wastewater Permit Application Technical Report Page 41 of 66

Attachment NOC-AE-14003142 Page 64 of 155 Worksheet 5.0 Sewage Sludge Management and Disposal

Attachment NOC-AE-14003142 Page 65 of 155 WORKSHEET 5.o SEWAGE SLUDGE MANAGEMENT AND DISPOSAL THE FO ILOWING I S R EQUIRED FO R A LL T PDES PER MIT A PPLICATIONS THAT M EET T HE CONDITIONS AS OUTLINED I N T ECHNICAL REPORT 1.o, ITEM NO. 7.

a. Is this a new permit application or an amendment permit application?

0 Yes E] No *The amendment requests will not change the sludge handling process at the facility.

b. Does the facility discharge in the Lake Houston watershed?

R Yes 0 No If yes to either item a or b, Indicate by a check mark that a solids management plan was provided with the application. E-] N/A, see note above.

P 4AE~~~A4 NAiL QA~(ntcl;~e 4).

a. Please check t he current sludge disposal m ethod(s). More t han one method can b e checked.

[] Permitted landfill

[] Marketing and distribution by the permittee

-- Registered land application site n-] Composted by the permittee

[ Surface disposal site (sludge monofill)

D Transported to another WWTP (written statement or contractual agreement required)

[] Beneficial land application as authorized in the existing permit

b. Disposal site name: Blue Ridge Landfill, TCEQ Permit/Registration Number: 1505 County where disposal site is located: Fort Bend County C. Method of Transportation (truck, train, pipe, other): Truck Hauler Registration Number: Aqua Zyme Services, Reg.. No. 21480 Transported in: FI liquid E semi-liquid F-1 semi-solid Z] solid state Land application for: EL Reclamation R Soil Conditioning
d. If the existing permit contains authorization for sludge land application, composting, marketing and distribution of sludge, and/or sludge lagoons and authorization t o renew t he activity is being s ought in t he application, t he appropriate s ections o f t he Sludge Technical Report must be provided.

TCEQ-1 0055 (05/15/2012) Industrial Wastewater Permit Application Technical Report Page 45 of 66

Attachment NOC-AE-14003142 Page 66 of 155 WJouA xMo S ~~Ag S

~TD'GEPR'S- SOSAL A hcio '4s,7a~5~

Are you requesting new authorization to beneficially land apply sewage sludge at this site or a site under your direct control?

Mi Yes 0 No Are you requesting new authorization to market and distribute sewage sludge at this facility or a facility under your direct control?

[] Yes W1 No Are you requesting new authorization to compost sewage sludge?

[D1 Yes IZ No Are you requesting new authorization to surface dispose sewage sludge at this site or site under your direct control?

M Yes IZ No Are you requesting new authorization t o in cinerate sewage sludge at t his site o r site under your direct control?

ElYes WZINo If yes to any of the above it ems, provide the information required in the S LUDGE TECHNICAL REPORT.

New authorization for beneficial land application, incineration, and sludge lagoons in the TPDES or TLAP permits requires a major a mendmentto t he p ermit. New authorization for composting may require a major amendment to the permit. See the instructions for an explanation whether a major amendment Is required or if authorization for composting can be added through the renewal process.

TCEQ-1 0055 (05/15/2012) Industrial Wastewater Permit Application Technical Report Page 46 of 66

Attachment NOC-AE-14003142 Page 67 of 155 Worksheet 7.0 Storm Water Runoff

Attachment NOC-AE-14003142 Page 68 of 155 WORICSHEET 7.0 STORMWATER RUNOFF WORIKSHEET REQUIRED FOR ALL TPDES PERMIT APPLICATIONS APPLYING FOR INDIVIDUAL PERMIT COVERAGE FOR DISCHARGES OF STORM WATER RUNOFF.

1. Do discharges from a ny of the p roposed or e xisting outfalls consist of stormw ater runoff only o r s tormwater runoff and any of the l isted n on-stormwater discharges?

(See Instructions, Page 79)

W-Yes IZINo If yes, proceed as directed. If no, stop here.

2. Indicate by a check mark which type of authorization covers or is proposed to cover discharges from each stormwater outfall. (See Instructions, Page 79)

U.n.:.e::**:.r:...**.:.  :..... ..u a....

outfallI coverage Coverqag U'nde.r oulI coverbkoe ,

coverage Under-UdrMGP Indiv"idual. Permit utar Under MSGI' In'dividual Pelrnitý

4. 4. .11 4 L 4 - 4* -II - I

- J. .11 A - L If you have indicated that all existing or proposed stormwater outfalls are covered under the MSGP, stop here. If you have indicated that you are seeking authorization under an individual permit, proceed as directed.

TH OU~0* GVrM ARE R]IAC

!EQ.~~)F obTFAtlHA. ..

DISCH GES StOIMWATERANDT OR WT6IIfY`OtJARESEEKICN(

~N WýMALftTO1UZATON UNDER MlIfS PERMIT APPLICATION.

Indicate by a check mark that a site map(s) of the entire facility has been provided with the following information.

H the location of each stormwater outfall to be covered by the permit; an outline of the drainage area that is within the facility's boundary and that contributes storm water to each outfall to be covered by the permit; LI connections or discharge points to municipal separate storm sewer systems; nI locations of all structures (e.g. buildings, garages, storage tanks);

nI structural control devices that are designed to reduce pollution In storm water runoff; process wastewater treatment units (including ponds);

El bag house and other air treatment units exposed to precipitation or runoff; landfills; scrapyards; surface water bodies (including wetlands);

TCEQ-1 0055 (0511512012) Industrial Wastewater Permit Application Technical Report Page 51 of 66

Attachment NOC-AE-14003142 Page 69 of 155 E vehicle and equipment maintenance areas; ED physical features of the site that may influence stormwater runoff or contribute a dry weather flow; D locations where spills or leaks of reportable quality (as defined in 3o TAC §327.4) have occurred during the three years b efore this application w as submitted t o obtain coverage under an individual permit; and ED processing areas, storage area, material loading/unloading areas, and other locations where significant materials are exposed to precipitation or runoff.

a. Provide an inventory, or list, of materials currently handled at the facility that may be exposed to precipitation.
b. Provide narrative descriptions of the industrial p rocesses and activities involving the materials in the above-listed inventory that occur outdoors or in some manner that may result in exposure of the materials to precipitation or runoff.

TCEQ-1 0055 (05/15/2012) Industrial Wastewater Permit Application Technical Report Page 52 of 66

Attachment NOC-AE-14003142 Page 70 of 155

c. Describe any best management practices and controls that you are using to prevent or effectively reduce pollution in stormwater discharges from the facility.

TCEQ-1 0055 (05/16/2012) Industrial Wastewater Permit Application Technical Report Page 53 of 66

Attachment NOC-AE-14003142 Page 71 of 155 poJVA4 4-t1$ ~ ti gs800)

a. TABLE i-SW: Please complete the table as directed.

Outfall ____MXUM~VAL~ nflYA ~ ~ ~ ~

/.Grab Grab "lw Plow Number 'of SmlWeighted Sample Weighted Storm M1AL Composipotie

~~ 116tI~~rn Sample 7 Sampled pH (Standard Units) (min) (max) (min) (max) .....

Total Suspended Solids Chemical Oxygen Demand Total Organic Carbon OIl and Grease Total Arsenic 0.010 Total Barium 0.010 Total Cadmium 0.001 Total Chromium '0.010 Trivalent Chromium Hexavalent Chromium 0..010 Total Copper 0.010 Total Lead 0.005 Total Mercury ... 0.0002 Total Nickel 0.010 Total Selenium 0.010 Total Silver 0.002 Total Zinc 0.005 TCEQ-10055 (05/15/2012) Industrial Wastewater Permit Application Technical Report Page 64 of 66

Attachment NOC-AE-14003142 Page 72 of 155

b. TABLE 2-SW: Please complete the table as directed. (Instructions, Pages 8o)

STR EE~TO K(t"q~ Pag.

Please provide the following data for the storm event(s) which resulted in the maximum values for the analytical data submitted:

a. Date of storm event:
b. Duration of storm event (in minutes):

C. Total rainfall during storm event (in inches):

d. Number of hours between beginning of storm measured and end of previous measurable rain event: hours
e. Maximum flow rate during rain event (gallons/minute):

Total stormwater flow from rain event (in gallons):

g. Provide a description of the method of flow measurement or estimate:

TCEQ-1 0055 (05115/2012) Industrial Wastewater Permit Application Technical Report Page 55 of 66

Attachment NOC-AE-14003142 Page 73 of 155 Attachment A Copy of Application Fee 4

Submission Checklist, Pg. 1

Attachment NOC-AE-14003142 Page 76 of 155 Attachment B USGS Maps

(

Admin Report 1.0 - 8.m., Pg. 12

Attachment NOC-AE-14003142 Page 77 of 155

THIS PAGE IS AN OVERSIZED DRAWING OR FIGURE, THAT CAN BE VIEWED AT THE RECORD TITLED: BLESSING SE, TX DMA 6741 I SE-SERIES V882 Attachment B 1USGS MAP WITHIN THIS PACKAGE...

02D01

THIS PAGE IS AN OVERSIZED DRAWING OR FIGURE, THAT CAN BE VIEWED AT THE RECORD TITLED:PALACIOS NE, TX, DMA 674111 NE-SERIES V882 Attachment B USGS MAP WITHIN THIS PACKAGE...

02D02

THIS PAGE IS AN OVERSIZED DRAWING OR FIGURE, THAT CAN BE VIEWED AT THE RECORD TITLED :IM[ATAGORDA,TEX, AMS 6841 III NW-SERIES V882 Attachment B USGS MAP WITHIN THIS PACKAGE...

02D03

THIS PAGE IS AN OVERSIZED DRAWING OR FIGURE, THAT CAN BE VIEWED AT THE RECORD TITLED: WADWORTH,TEX, AMS 6841 IV NW-SERIES V882 Attachment B USGS MAP WITHIN THIS PACKAGE...

02D04X

Attachment NOC-AE-14003142 Page 82 of 155 Attachment C Affected Landowners Admin Report 1.1 - I.a. & b., Pg. 15

Attachment NOC-AE-14003142 Page 83 of 155 LEGEND

_____ South Toxas Nucear Plant

- Adjacent Landowners A Outfial Location

  • kntenl Monwfto Points Upstreanrvownstrea Markers

-- Disharge Route a 200 4X SOUTH TEXAS NUCLEAR PLANT MATAGOR.DA COUN~TY. 7EXAS ATTACHIENT C AFFECITE LANOWES AP

-It my *sin tt wj. *jw. ao.T4 O.Cs'b Vts , PLS Um

Attachment NOC-AE-14003142 Page 84 of 155 MAPIl RIle...otn addrjine2 add_dRW addr..%ate zip 3 AARONREVOCABLE TRUST SBENGUSHOAK LAKEJACKSON 77566 2 ABERWILLIAM M 1R &LAURAA ABER 1640 CR243 BAYCITY "TX 77414 3 ADAMSALLENM 1610 CR 243 SAYCITY Tx 77414 4 ALKIRE WILULAM & LYNNO'BRIEN 372 CR 243 BAYCITY Tx 77414 5 ALLENMAREEL& EDITHM LANIERPRUITT 18350 FENSKE CYPRESS 73433 6 ARNIMA H 5 CARYN BRBEXOTICISLE BAYCITY "TX 77114 7 BARTON GARYR& DEANNA M 4708 WELFORD DRIVE BELLAIRE TX 77401 0 BARTON SEANE &BETHA 471 USNDEN BELLAIRE *77401 Tx N BENNETT TIMOTHY T& CONNIEI 2700 CYPRESS SPRINGSLN CYPRESS 77433 TX 10 BLACK MICHAELW&ALUSON 1618 CR243 BAYCITY 77414 11 BOWERS YV P G BOX799 PALACIOS 77465 12 BRANIFF JOHN RJR &MELISSA 6230 LYNBROOK HOUSTON TX 77037 13 BROWNDIANAL 2076 CR243 RAYCITY TX 77414 14 BROWNTRACEPROPERTIES LTD 3606 YVENUE F BAYCITY TX 77414 15 BURDITTTOMMIE W &JUDYL&TROYW JOA 5924 HOMESTEAD ROSENBERG TX 77471 16 CANTRELL JAMESS 302 EMPRESS LANE LEAGUECITY TX 77573 17 CARROLL JOHNNIE LEE 1071 CR385 PALACIOS 77465 1i CARROLL WAYNE&SUE 352 CR 243 BAYCITY Tx 77414 19 CHANCE FARM P 0265 FBOX WICHITAFALLS Tx 76307 20 CHAPPELL COLEY & LOREEELTON 2010 CR243 SAYCITY TX 77414 21 CHERYL WIITE INC 607 SALERNO SUGARLAND 0X 77478 22 COLUERBILL & RUBY H61 CALADIUM COURT LAKEJACKSON T3 77566 23 COR0RON ALLEN ROY 625 GREENDEWITTRD CUERO 77954 24 COXJANEM 1540 CR243 BAYCITY T3 TY TX 77414 25 COXTHOMASBRENT &TERRILYNN 550CR 243 SELKIRK RD BAYCITY TX 77414 26 CRAINGARY& KAREN 1190 CR243 (SELKIRS RD) BAYCITY TX 77414 27 COANEJOE M 2909 OAKDR BAYCITY TX 77414 28 CULVER RAYM JR 306 PRIVATE ROAD608 BAYCITY TX 77414 29 DAVISCLYDE I 1320CR243 SELKIRK RD BAYCITY T1 03 77414 30 DAVISJEFFR &BETTYS P 0 BOX3196 PORTLAVACA 03 0X 77979 31 DAYJEREMY 10684 CRf303 PLANTERSVILLE 77363 32 DEFEHR KEITHD &BARBARA P BOX0 126 WADSWORTH TX 77483 33 DENHAMALFREDB P G BOX1792 RAYCITY 77404 34 DORRFRANKD 17603 WESYTLEIGH DR HOUSTON TX 77077 35 DZIUKROBERT J/HELEN/JEFFERY& STACYATTAWAY 1824 SUNSETDR BAYCITY T3 77414 36 ELYJAMESE 1700GOLDEN AVERI100 RAYCRY TX 77414 37 ESTES DANIEL EDWARDIII&TAMMYRESEE P0 BOX27 ELMATON TX 77440 33 EXOTICISLEHOMEOWNERS ASSOC 1322 BETEEL HOUSTON 77055 39 FALTYSEK NATHAN RAY& KERA 2021 HIAMILTON DRIVE ROSENBERG 0X 77471 40 FLORE5JAMESW &THOMAS0 J1B3 WILLOWSTREET BAYCITY TX 03 77414 41 FLOYD CHARLES RESTATE 1700 :COUNTY ROAD243 BAYCITY TX T5 77414 42 FREEMAN FAMILYTRUST P G BOX789 BROOKSHIRE Tx T3 77423 43 GAERTNER DEANR& MARYBESHGAERTNER 27002 MESAVERDEDRIVE MAGNOLIA TY 77355 44 GATELY FRANCIS &JOYD 1802 CR 243 BAYERY 03 77414 45 GAVENDER M E& ROSALIE 1990 CR 243 BAYCITY T3 77414 45 GAVENDER RONALD F PG EOX372 WADSWORTH T3 77483 47 GILLILAND ANGELA M R20TW 3TH ST HOUSTON 03 TX 77018 40 GOODMANLESLIE L 18100FFPP PASADENA TX TX 77502 49 GREGORY JAMESF 411 S BELKNAP ST SUGARLAND T0 03 77478 GROTHALISONEGSTEXEMPTDE3CENDANTS TRUST SSSSSANFELIPESTE200 HOUSTON Tx T3 77056 51 GROTHCARLE &KATHY D 2811 GOLDEN LARCHDR KATY 03( 77494 52 HANSEN DORISBUNGEFAMILY TRUST2012 7282 1'M521 PALAClOS 77465 53 HARRISON GEORGER& DONNACORNELIUS 2486 CR 222 BAYCITY 77414 54 T3 HENDERSON ROBERT KJR 535 AZALEADELL DR HOUSTON 77018 55 HICKSMICHAEL &CHARLENE 20822 RIVAFUDGE FAIROAKSRANCH 78015 56 HINOTERUSSELL E& DIANE 2315 OAKVIEW DR MISSOURICIE 774159 57 HOWAATONMARIONL& VWCKIE E 720 CR243 BAYCITY 77114 so HUBBARDPROPERTIES LTD PO BOX2&3 VANVLECK 77.00 59 HUGHEYJOHN R 59 EXOTIC ISLEDRIVE BAYCITY 77414 60 IVYDONALD D &JOYCE 2058 CR 243 DAYCRIY 77414 "X

61 JANISENATHANS&PAMELA S 592 CR243 BAYCITY 77414 62 JOHNSONDIRK19 KIM8RAK 3313 ASPENBEROOK COURT PEARLAND 77581 IL 63 JONESJEANNIE R 726 S PRAIRIERD NEWLENOX 60,151 TX 64 KEYMARTINL&DONNAL 9810SPINGFIELD RIDGEDR KATY 77494 T0 65 KIENTZCALVIN W 3669FM2268 BAYICRY T3 77414 66 KIRBY BRENTT& SUEW P 0 BOX32 WADSWORTH 71413 TX 67 KNAPPDEBBIE KIRE PG BOOX4179 HOUSTON T3 77210 68 OH SOSTESSAUDER HARRY 8 & SHERYE. LSZEINBACH P0 BOX211101 COLUMBUS T3 43221 69 KRENEK LARRYJ&DEANNAH 32653 PECANHILL BROOKSHIRE TX T3 77423 7n LANDERS JOHNS SR&JANEC 2014 COUNTY ROAD243 BAYCTY TX 77414 71 LEDWIGJULIUSH RR & SCOTT D LEDWIG PG BOX190 BLESSING TX T3 77419 7Z LEISSNER DAYTON LANE 5619 CR112 VANVLECK TX T3 77402 73 LESLIE JESSICA 110 CANYON DRIVE SANANTONIO 0X TX 78209 74 LIGUMSJOHNE& IENNIFER H 3736 KNOLLWOOGST HOUSTON T1 77019 75 LOYACANO RAYDALE&FRANCES 448 CR243 BAYCETY IL 77414 76 MARTIN JERRYL& KATHRYN 1R78CR243 BAYCITY TX 77414 77 MASSEY DAVE& NANCY SPEICH 4021 BYRON HOUSTON T3 7700S 78 MATHERNE TERRY A &SUSANK 4841 BRAIRBEND DRIVE HOUSTON TX 77035 70 MCELMURRAY ELIHENRY 1718 CR243 BAYCIE 77414 MCGEE CLAUDE&BARBARA PRESLEY 700 AVENUE F NORTH BAYCITY 77414 81 MCKINLEYJESSE G ETAL 12522 CAMPSITE TRAIL CYPRESS TX 77429 83 MILER SEAN GORDON P0BOX669 8AYCERY 77404 MILLER RONNIELAVELLE 2404 AVENUE H BAYCETY 77414 64 MOBLEY LARRY W & CAROL I 1810 CR243 77414 BAYCITY 05 MOFFITTREALESTATE I LLC 13002 KLUGE RD CYPRESS 77429 MONTGOMERY JACKC &BARBARA I 435 FOXBRIARLANE SUGARLAND 77478 07 MORRISSTEVEI 5151EDLOEAPT9107 HOUSTON 7700D 8R NIELSEN DONALD & MARYJEAN 1910 CR243 RAYCITY 77414 TR OCONNEILL PATRICK I 10101 SOUTHWEST FWYSTE100 HOUSTON 77074 00 OWENBESSIE MAE 15318ARHWOODDR SUGARLAND 7747B 91 TX PAJESTKA BLANCHE P 0 BOX105 HOLLAND 76534 02 PETRVALSEK GERALD& MARGARET ELLENPETRVALSKY 6717 COTTON HOUSTON 77092

Attachment NOC-AE-14003142 Page 85 of 155 PHILLIPSBRIANM &PAMELA A 5EW HIGHWAY 36 N BELLVILLE 77418 PLUMMERCHIEDRENS' TRUST 2101 CRAWFORD ST STE302 HOUSTON 77002 PLUMMERMATTHEW W JRTRUSTEE 2101CRAWFORDSUITE 204 HOUSTON 77002 POPPCEDRICE &JOANN 4612 CR 410 RD ELCAIMPO 77437 POSTERWARTREUR 1999 REVOCABLE 4408 LONGCHAMPDRAPTS8 AUSnN 78746 POSWAYJOHNP &ELISSA 6903 ELMTRACEDR SUGARLAND 77479 PURYEAR MARILYN ANN 334 CR243 / SELKIRK RD BAYCITY 77414 PYATTE JOSEPHB 1070CR 243 BAYCITY 77414 QUINNEY JOSEPHF P 06X.71 MARKHAM 77456 RADITETRAVIS WILUAM&NICOLEP E13TWINPINESDR FRENDSWOC)D 77546 REUSERUSSELL P &ALYCE J 30702 MCKINNEY DR TOMBALL 77375 RICHARDSON JERRY& BARBARA P B BOX911 WADSWORTH 77483 ROBERTS PAULD &LINDAI 29017TH1TR363 BAYCITY 77414 ROYCHRISA& KELLIE D P BOX C 926 SANTEFE 77517 RUNNELLS CLIVE III P0 EOX 5097 AUSTIN 78703 RUNNELLS CLIVEIV P 0 EOX5097 AUSTIN 79763 SAHAJOHN BYRON &AMANDAKAY 2E95 CR391 PALACIOS 77465 SALAZAR RUBEN 4702 MIMOSACIR RICHMOND 77406 SAMSCLEOLESTER & MARYK 2(B CR243 BAYCITY 77454 SAVAGE JOHINMORRIS 4797 FM 2853 PALACICS 77465 SAVAGEKEN&CINDY 1652 CR 243 DAYCITY 77414 SCHEPSBRENT 550COLLEGE BELLAIRE 77401 SCHWARTZ SIDNEY TRUSTEE 1940AVENUE G BAYCITY 77414 SELKIRK ISLANDIMPROVEMENT COMMITTEE 1650CR243 BAYCITY 77414 SHEPPARD IIENRY C 5207 MARBLE GATE HOUSTON 77069 SHERRILL KAREN 11707 CEDARPOINTCOURT HOUSTON 77070 SILLERSCYNTHIABREVTRUST 5555 45TH ST MOORHEAD 65160 SILVERTHORNE KENNETH W 1574CR 243 BAYCITY 77414 SNYDER JAMESEUGENE & CAROLYNL 1930 CR 243 SELKIRK RD BAYCITY 77414 SPECKFAMILY LIVINGTRUST 11D2SYCAMORE RD RICHMOND 77469 SPROTTHANNAH ASHIEY 9479 LIGH.SEY LN COLLEGESTATION 77540 SPROTTSHERRY LCULVER 9479 LIGHTSEY LN COLLEGESTATION 77*45 STEFFEK KEITH A & JONNIEE 7601 SWANSONDR RICHMOND 774G6 SZEINBACH SANDYA 1054 CR 243 DAYCITY 77414 TALASEK MELVINB P 0 BOX397 WADSWORTH 77463 TALASEK MICHAEL M & KARSEJ TALASEK P 0 BDX278 MATAGORDA 77457 THESCHINDLER UVING TRUST 1LSWESTEVANS WHARTON 77488 THOMASHARRY R1R & DIANA 2108 CR243 BAYCITY 77414 TILLER DAVEGUYI11&TALBOTT FAMILYLIVINGTRUST 2613 TUPELO BAYCITY 77414 TRACYTRENTN P0 BOX350 WADSWORTH 77483 TRAHANRONALD L&GAILE 2704 CR243 BAYCITY 77414 TURNERGERALD D 33Z7 EASTOVERDALE PEARLAND 77584 URBAN*EK ALBERT AIR& ANNETTE L 7402 FP 361 RICHMOND 77469 VANCEJOAHN T III&ELIZABETH 3100 AVENUE H BAYCITY 77414 VAUGHAN WATTSRARD&PATSYKAYE VAUGHA N 1493 CR243 BAYCTTY 77414 VAVRA JARRETT&TAMMY 3458 CR 384 PALACIOS 77465 VAVRA MILTONJR 415 CR 353 PALACIOS 77465 WALKER TEDL& LORT I 402 MAIN9TH FLOOR HOUTO N 77002 WARRKENNETH HJR &CHRISTIAN SWINBANK P 0 BOX1127 FULSHEAR 77441 WEDEMEIER THOMASM 1420R5243 BAYCITY 77414 WENZEL CHARLES E &MARIELLEN 2701 PARKWAY ROSENBERG 77471 WESTMORELAND GREGB 18VALHALLA DR BAYCITY 77414 WIKOFPLEEE A KERRI 1650CA 243 BAYCETY 77414 WINTERSJOSEPHP &DOLORES 252 CR243 BAYCIT" 77414 YOUNGROBERTAUSTIN P0.BOX632 MATAGORDA 77457 ZABOROSKI EUGENE&SELPHINE 184 LCR743 A THORNTON 76687 ZARRANSKY MICHAEL C& RUTH 6529MERLIN HOUSTON 77055

\.,. /f

Attachment NOC-AE-14003142 Page 86 of 155 Attachment D Original Photographs Admin Report 1.1 - 2., Pg. 12

Attachment NOC-AE-14003142 Page 87 of 155 RPS

Attachment NOC-AE-14003142 Page 88 of 155 Attachment D - Outfall Photos Photo1 - Outfall 002 Photo 2 - Outfall 001, Looking downstream

Attachment NOC-AE-14003142 Page 89 of 155 Photo 3 - Outfall 001 looking out Photo 4 - Outfall 003

Attachment NOC-AE-14003142 Page 90 of 155 Photo 5 - Outfall 004 Photo 6 - Outfall 005

Attachment NOC-AE-14003142 Page 91 of 155 Photo 7 - Outfall 006

Attachment NOC-AE-14003142 Page 92 of 155 Attachment E USGS Map SPIF, Item 8

Attachment NOC-AE-14003142 Page 93 of 155 Downstream of 1WIMile OutOfll 003 Doitam of Downstream Outf Ou t fa Ul 0 053 SouthTexn ud....lan the.FullSze"W Wa I s ho n Map as required.

n 00 1 & 004 Imile radius N A outfall Location 0 2,500 5%ODO

  • Intemal Monitoring Points FEET Ad WMRLocations (TWDB)

War 4 -C = =rw, DRAWN SY: SB WIVLSON SOUTH TEXAS NUCLEAR PLANT MATAGORDA COUNTY, TEXAS APPROVED BY: T KOEIN PROJECT NO: 2014 TPDES ATTACHMENT E FILE NO. STNSPIF MAP.m,.

SPIF USGS MAP DATE. MAY2014 A; = Wsz: MM-9ml,ýwina'Iý-

Attachment NOC-AE-14003142 Page 94 of 155 Attachment F Wastewater Generating Process Tech Report 1.0 1.c., Pg. 1

Attachment NOC-AE-14003142 Page 95 of 155 Attachment F - Wastewater Generating Process Main Cooling Reservoir -- Outfall 001 Outfall 001 is the discharge point for the 7,000-acre main cooling reservoir. This reservoir is part of the main recirculating cooling water loop used to remove heat from the steam-electric generating units.

There has not been a discharge from Outfall 001 since March 1997 otherthan minor permitted leakage through the closed spillway gates and relief wells. If a discharge were to occur, blowdown from the main cooling reservoir would make up the largest percentage of wastewater. A discharge from Outfall 001 would flow to the Colorado River (Colorado River Tidal in Segment 1401 of the Colorado River Basin).

All internal outfalls (Outfalls 101, 201, 401, and 601) discharge to the main cooling reservoir. Outfall 501 would also discharge to the reservoir via Outfall 101, but has not discharge since 1992.

Low Volume Wastewater (Outfalls 101 and 201)

Low volume wastewater results from water treatment operations, boiler blowdown, HVAC blowdown, floor drains, SPCC sources and their associated oily water treatment system discharges, and other miscellaneous sources. Boiler blowdown is from one auxiliary steam boiler, released to reduce impurities in the water that can cause corrosion and boiler tube failure. Service water is demineralized and regeneration of the demineralizer resin beds produces an acidic and caustic wastewater that is treated at the neutralization basins along with boiler blowdown. The floor drain system captures condensate and water from production and maintenance areas that may contain oil or grease, which is then transported to the oily waste treatment system where the oil is separated from the water. The first flush of stormwater from some production and storage areas is also treated in the oily waste system. Other non-processstormwater flow is directed through designated stormwater outfalls.

Treated Domestic Wastewater (Outfalls 401 and 601)

Domestic wastewater is treated onsite in two package treatment systems consisting of aeration, clarification, and disinfection. Car wash water, air conditioning condensate, HVAC cooling tower blowdown, and stormwater are commingled with the domestic wastewater prior to treatment.

Metal Cleaning Waste (Outfall 501)

Metal cleaning waste has not been discharged since 1992. Metal cleaning using chemical or non-chemical liquids produces a waste that would be discharged through Outfall 501 to the neutralization basins (Outfall 101). Stormwater may also be discharge through Outfall 501.

Main Cooling Reservoir (MCR) Relief Well Effluent (Outfolls 002-006)

MCR relief well effluent is collected from the perimeter of the MCR and discharge via Outfall 002-006 without treatment. Outfall 002 is also authorized to discharge demineralized water from Instrumentation.

Attachment NOC-AE-14003142 Page 96 of 155 Attachment G Facility Plot Plan Tech Report 1.0- I.e., Pg. 2

Attachment NOC-AE-14003142 Page 97 of 155 I IWA0U IIIM MATAGAM ILDUIA;LrAi COUNIY. 7EXA PLA"I h

)k ATTACNMNTO LEGEND Soulh T~*as I*,dsor Pft qiý mo w tsvamo

~m T~

FACOfrYS so&&US1~

S MTAP l~.r 3m LUnftsI £2

ýw mm ~'=1 ii A OujhILocaflbn MET rn-U-----

II 0 knesiAo MwV cib t IS-w

Attachment NOC-AE-14003142 Page 98 of 155 Attachment H Flow Schematic Diagrams Tech Report 1.0- 2.b., Pg. 3

Attachment NOC-AE-14003142 Page 99 of 155 Colorado River SOUTH TEXAS NUCLEAR PLANT MATAGORDA COUNTY, TEXAS Notes:

Outfall has not discharged since March 4, 1997.

ATTACHMENT H

    • Outfall has not discharged since December 1992.

FLOW SCHEMATIC - OUTFALL 001 DRAW,/N BY SSW"LSODI SCALE! PROJ. 2014TDOES CHECKEDBY:T KOENINGS De.

b sRRI F[LENO. STNoFI..D.o0r,,e..wg APPROVEDBY: DATEPRINTED DATE: U, 12,231 A-t S, £.dA a

Attachment NOC-AE-14003142 Page 100 of 155 Effluent from Relief Wells W1.W125 OUTFALL 002 Plant drainage ditch to Colorado River, Tidal Am -

w Demineralized Water from Instrumentation SOUTH TEXAS NUCLEAR PLANT MATAGORDA COUNTY, TEXAS ATTACHMENT H FLOW SCHEMATIC - OUTFALL 002 DRAWANBY: S,3VLSON SCALE: PROJ. 201 4TPDES CHECKEDBY:T KOEWJINDS Z.. b., -le FILE NO. SRJI4 Osa APPROVEDBY: - DATEPRINTED:

DATE: M.,t2.2014 t~M 0.,* R*01,g57R.3. 100 2050C*Ol.1 tl Ta,..H~5W*II S0011 I

[ 7Rý7PS] r.n, 7,745 01,140 1.7145 010.51

Attachment NOC-AE-14003142..

Page 101 of 155 I OUTFALL 003 Effluent from Relief Wells I West Branch of the WI 38-W195 W Colorado River OUTFALL 004 Effluent from Relief Wells Main Cooling Reservoir W196-W268 Spillway W

OUTFALL 005 Effluent from Relief Wells AI East Fork Little Robbins W269-W483 w SloughI OUTFALL 006 Effluent from Relief Wells Little Robbins Slough W483-W670 i - a-SOUTH TEXAS NUCLEAR PLANT MATAGORDA COUNTY, TEXAS ATTACHMENT H FLOW SCHEMATIC -OUTFALL 003, 004, 005, 006 DRAM BYA: SSWMLSON SCALE: PROJ. 2014WMES CHECKED8Y:TKOENINGB Se 'br oIP FILENO.

' LL...l, '*

APPROVEDI BY DAE PRINTED:

0 CIA 14 DATE:

0 DV, On. BI44~g2'.DVi 000 0404Cot.S.VTIa.JVOA.,.o.

S~4A RpýS A4t 70,08 d(2041.7MD 10740 b

Attachment NOC-AE-14003142 Page 102 of 155 LOW VOLUME WASTEWATER recirculation line including wastewater from the following operations and sources:.

  • demineralizer regenerant wastewater;
  • condenser polishing regenerant wastewater; OUTFALL101
  • boiler blowdown; NEUTRALIZATION BASINS
  • boiler drainage;.
  • laboratory, instrument, and sampling sources; Neutralization*

I - Mixing*

  • well water filter backwash; Sedimentation to Main Cooling
  • water softener regenerate; Reservoir
  • floor drains in chemical storage containment areas;
  • rinse water from triple rinsing empty chemical drums;

, fuel handling building HVAC blowdown; and

  • miscellaneous low volume wastewater.

sludge to landfill Metal Cleaning Waste Effluent Storm Water (Outfall 501"*)

SOUTH TEXAS NUCLEAR PLANT MATAGORDA COUNTY, TEXAS Notes:

'Treatment may be used based on influent quality ATTACHMENT H

- Outfall 501 has not discharged since December 1992. FLOW SCHEMATIC - OUTFALL 101 DRAMIBY: SSWILSON SCALE. PR04, 2514TPOES CHECKEDBY:KOENINOS ,t Be*ba 5cl. FILENO0. GNJS.Y.*Stl,,t APPROVEDB:jS 22 DAT PRINTYED DATE:

I

Attachment NOC-AE-14003142 Page 103 of 1556 sludge to incineration and/or landfill

- - -- w- filter media to landfill SOUTH TEXAS NUCLEAR PLANT MATAGORDA COUNTY, TEXAS Notes:

ATTACHMENT H

      • Treatment process may be used based on influent characteristics. FLOW SCHEMATIC - OUTFALL 201 SS=tLSON SCAL.E: PROJ. 2E14TPDES "KOENINGS1 See Sa' cIe FILENO. NFSw ,

- DATEPRINTED: I

ýýM 01.5 C..t. A.iObORS,,*bIX 1210C~ftI~4 ShVft~.o r RPSI 0005170043 P~T0O

Attachment NOC-AE-14003142.

Page 104 of 155 AERATION TANKS Activated Sludge Foam Suppression Screening L -----------------

OUTFALL 401 DIGESTER Sludge to landfill - --

Aerobic Digestion to Main Cooling Reservoir SOUTH TEXAS NUCLEAR PLANT MATAGORDA COUNTY, TEXAS ATTACHMENT H FLOW SCHEMATIC - OUTFALL 401 DRAMNBY: SSVVILSONSCALE: PROJ. 2014ITPDES CHECKED BY:T KOENINOS S50 b.-.1 ILE NO.

FS~ DThYoa APPROVE BYOR DATEPRINTED:

DATE:

~~2 1~-H5,-,.S1 O

monommomwjbý

Attachment NOC-AE-14003142 Page 105 of 155 OUTFALL 501 Metal Cleaning (no discharge since 1992)

Inorganic Basin Wastetwater

-- Coagulation' to Outfall 101 Chemical Precipitation*

Sedimentation Storm Water SOUTH TEXAS NUCLEAR PLANT MATAGORDA COUNTY, TEXAS ATTACHMENT H FLOW SCHEMATIC - OUTFALL 501 DRAWNBY: SSW1LSON SCALE PROJ. 2014TPOES CHECKEDBY;T KOEtNO1 U0 bar ato S j FRLENO. ST._Fl R- ,.g APPROVEDBY: - DATEPRINTED; Notes: DATE; Ua. 12.20114

  • Treatment process may be used based on influent characteristics.

B.do23I 23,4?.

23* Card,.. 2300 42350 CR232323 at 31,50 N00fl. Stat,

  • a,1431 Faa..00746 i

I RPS]

Attachment NOC-AE-14003142 Page 106 of 155' AERATION TANKS Activated Sludge Foam Suppression Screening OUTFALL 601 DIGESTER Aerobic Digestion I. to Main Cooling Reservoir sludge tolandfill SOUTH TEXAS NUCLEAR PLANT MATAGORDA COUNTY, TEXAS ATTACHMENT H FLOW SCHEMATIC - OUTFALL 601 DRAWNRY: SD LSON SCALE: PROJ. 2014TPDES CHECKEDBY:T KOEINGS So.. batbscar FILENO. STNFl, FIS-ll,.E,.

APPROVEDRY: - DATEPR1NTE:

DATE: 0.201 ,*.

"TAIML AI 20 a

Attachment NOC-AE-14003142 Page 107 of 155 Attachment I Water Treatment Chemicals Tech Report 1.0- 5.c., Pg. 8

Attachment NOC-AE-14003142 Page 108 of 155 Treatment Chemicals Product Manufacturer Use Components Listed in CAS Frequency of Toxicity Product Name MSDS Use Data Concentration In MSDS Sodium ypolorite 7681 3 times per day Univar :Biocidt for 20 minutes to Yes 0.15-0.6 ppm total LiquichSor 1310e73- unit's cooling residual chlorine Sodium Hydroxide 2 water Sodium nitrite 7632 As needed to 0.25 oz per gallon of 1359 Plus Nalco Corrosion inhibitor 7775 0 maintain No closed cooling system Sodium nictaborate 1 concentration water 19H Nalco Oxygen scavenger Hydrazine 302-011-2 Continuous Yes 0.1 ppm to feedwater Sodium Nitrite 7632 As needed to Nalco Corrosion inhibitor 0 maintain No 500-1500 ppm sodium LCS-60 Sodium Tetraborate 1330 concentration nitrite concentration 4.

1 935cNlcoNo Scale Polyacrylic Acid N/A Continuous 0.25 ppm federate as inhibitor/dispersant product 3 times per day ACTI-BROM Nalco Biocide Sodium bromide 7647 for 20 minutes to Yes 0.15-0.6 ppm total.

131.8 6 unit's cooling residual chlorine water B-2200 Varichem. Algaecide Ethyl Alcohol 64-17-S Batch treated as No 5 ppm needed B-2206 Varichem Biocide Broimochloro-5.5- N/A Continuous No 0.5-2 ppm diniethylydantoin Scale and SC-23 10 Varichen coaroaiondinibitor None listed N/A Continuous No 80-120 ppm

Attachment NOC-AE-14003142 Page 109 of 155 Didecyl-Dimethyl- 7173 4 ppm as product (2.5 H-130M Nalco Biocide Ammonium chloride 52/Yr. Yes ppm. as active) to aux.

Ethanol 64-17-5 cooling system for 8

-hours twice per year.

Magnesium Salt N/A 2-Methyl-4-Isothiazolin 2682 Batch treated as 77352NA Nalco Isothiazolin one 4 needed Yes 300 ppm 5-Chloro-2-Methyl 26172-

__sothiazolin-3-one 1 55-4 _ 1

Attachment NOC-AE-14003142 Page 110 of 155 UnIVAR@

Univar USA Inc Material Safety Data Sheet MSDS No: IOX7668*5 Version No: 010 2014-03-18 Order No; I ZI Univar USA Inc., 17425 NE Union Hill Rd., Redmond WA 98052 (425) 889 3400 Emergency Assistance For emergency assistance involving chemicals call Chemtrec - (800) 424-9300

Attachment NOC-AE-14003142 Page 111 of 155 UNIVAR USA INC. MSDS NO:OX76685 ISSUE DATE:2011-12-21 VERSION:010 2014-03-18 Annotation:

COMPANY IDENTITY: Univar DATE: 12/21/11 PRODUCT IDENTITY: Liquichiso 10-16% (Sodium Hypochsorite 10-16%) PAGE: 1 OF 8 SAFETY DATA SHEET This Safety Data Sheet conforms to ANSI Z400.5, and to the format requirements and the International Chemical Safety Cards of the Global Harmonizing System.

THIS SOS COMPLIES WITH 29 CFR 1910,1200 (HAZARD COMMUNICATION STANDARD)

IMPORTANT: Read this SOS before handling & disposing of this product.

Pass this information on to employees, customers, & users of this product.

SECTION 1. IDENTIFICATION OF THE SUBSTANCE OR MIXTURE AND OF THE SUPPLIER PRODUCT IDENTITY: Liquichlor 10-16% (Sodium Hypochlorite 10-16%)

SDS NUMBER: OX76685 NEW MSDS DATE: 12/21/2011 COMPANY IDENTITY: Univar COM1PANY ADDRESS: 17425 NE Union Hill Road COMPANY CITYý Redmond, WA 98052 COMPANY PHONE: 1-425-889-3406 EMERGENCY PHONES: CHEMTREC: 1-800-424-9300 (USA)

CANUTEC: 1-613-996-6666 (CANADA)

SECTION 2. HAZARDS IDENTIFICATION DANGERI!

EXPOSURE PREVENTION: STRICT HYGIENEI AVOID ALL CONTACTI RISK STATEMENTS:

R35 Causes severe burns.

RS Very toxic to aquatic organisms.

SAFETY STATEMENTS:

51/2 Keep locked up-and.out of the reach of children.... .....

~ w t ht*' iinf1'

. . .- . A v did c o n ta t '`

.. . .2 4 / 2 5 -ý ".... ... . . . . ...........

-d_ y len . .........

S36/37/39 Wear suitable protective clothing, gloves and eye/face protection.

526 In case of contact With eyes, rinse immediately with plenty of water and seek medical advice.

S28 After contact with skin, wash immediately with plenty of water.

S45 In case of accident, or if you feel unwell, seek medical advice immediately. (Show the label where possible).

561 Avoid release to the environment. Refer to special instructions/safety data sheet.

SECTION 3. COM1POSITION/INFORMAATION ON INGREDIENTS MATERIAL CAS# EINECS# WT %

Water 7732-18ý5 231-791-2 84-98 Sodium Hypochlorite 7681-52-9 *c 16 Sodium Hydroxide 1310-73-2 <= 1.75 Trace components: Trace ingredients (if any) are present in 4 1% concentration, (c 0.1% for potential carcinogens, reproductive toxins, respiratory tract mutagens, and sensitizers). None of the trace ingredients contribute significant additional hazards at the concentrations present in this product. All pertinent hazard information has been provided in this document, per the requirements of the Federal Occupational Safety and Health Administration Standard (29 CFR 193.6.1200), U.S. State equivalents, and Canadian Hazardous Materials Identification System Standard (CPR 4).

SEE SECTIONS 8, 11 8 12 FOR TOXICOLOGICAL INFORMATION.

Attachment NOC-AE-14003142 Page 112 of 155 UNIVAR USA INC. MSDS NO:OX76685 ISSUE DATE:2011-12-21 VERSION:010 2014-03-18 Annotation:

COMPANY IDENTITY: Univar DATE: 12/21/11 PRODUCT IDENTITY: Liquichlor 10-16% (Sodium Hypochlorite 10-16%) PAGE: 2 OF 8 SECTION 4. FIRST AID MEASURES EYE CONTACT:

If.this product enters the eyes, open eyes while under gently running water. Use sufficient force: to open eyelids. "Roll" eyes to expose more surface. Minimum flushing is for 15 minutes. Seek immediate medical attention.

SKIN CONTACT:

If the product contaminates the skin, immediately begin decontamination with running water. Minimum flushing is for 15 minutes. Remove contaminated clothing, taking care not to contaminate eyes. If skin becomes irritated and irritation persists. medical attention

-iffi-e-n--e-f9s-. i contaminatea-ch-inle-f*orreuse, discard c0ntaminatid shoes, Wa*-r INHALATION:

After high vapor exposure, remove to fresh air. If it is suspected that fumes, are still present, the rescuer should wear an appropriate mask or self-contained breathing apparatus. Keep person warm and at rest. breathing is difficult, give oxygen. If breathing has stopped, trained personnel should immediately begin artificial respiration. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. If unconscious, place in recovery position and get medical attention immediately.. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband. If the heart has stopped, trained personnel should immediately begin cardiopulmonary resuscitation (CPR). Seek immediate medical attention. In case of inhalation of decomposition products in a fire, symptoms may be delayed.The exposed person may need to be kept under medical surveillance for 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br />.

SWALLOWING:

If swallowed, CALL PHYSICIAN OR POISON CONTROL CENTER FOR MOST CURRENT INFORMATION. If professional advice is not available, give two glasses of water to drink. DO NOT INDUCE VOMITING. Never induce yomiting or give liquids to someone who is unconscious, having convulsions, or unable to swallow. Seek immediate medical attention.

NOTES TO PHYSICIAN:

There is no specific antidote. Treatment of overexposure should be directed at the control

.. m...ri.....

..... o..f-.sympdtrs.-andthe.,clinica.ondiionf-thezpatient. Anymatleriaaspirated.!u in g. ..

vomiting may cause lung injury. Therefore, emesis :should not be induced mechanically or pharmacologically. If it is considered necessary to evacuate the stomachlcontents, this should be done by means least likely to cause aspiration (such as: Gastric lavage after endotracheal intubation).

Victims of chemical exposure must be taken for medical attention. Rescuers should be taken for medical attention, if necessary. Take a copy of label and SDS to physician or health professional with victim.

SECTION 5. FIRE FIGHTING MEASURES FIRE & EXPLOSION PREVENTIVE MEASURES Not Applicable.

EXTINGUISHING MEDIA Use dry powder, foam, carbon dioxide, water spray, halon, or any "ABC" Class extinguisher.

SPECIAL FIRE FIGHTING PROCEDURES Water spray may be ineffective on fire but can protect fire-fighters

& cool closed containers. Use fog nozzles if water is used.

Do not enter confined fire-space without full bunker gear.

(Helmet with face shield, bunker coats, gloves & rubber boots).

Use NIOSH approved positive-pressure self-contained breathing apparatus.

UNUSUAL EXPLOSION AND FIRE PROCEDURES Noncombustible.

Isolate from reducers, acids, wood, organic materials, and most metals.

Oxidizer fumes damage lungs. Symptoms may be delayed. Do not breathe fumes.

Attachment NOC-AE-14003142 Page 113 of 155 UNIVAR USA INC. MSDS NO:OX76685 ISSUE DATE:2011-12-21 VERSION:010 2014-03-18 Annotation:

COMPANY IDENTITY: Univar DATE: 12/21/11 PRODUCT IDENTITY: Liquichlor 10-16% (Sodium Hypochlorite 10-16%) PAGE: 3 OF 8 SECTION 6. ACCIDENTAL RELEASE MEASURES SPILL AND LEAK RESPONSE AND ENVIRONMENTAL PRECAUTIONS:

Uncontrolled releases should be responded to by trained personnel using pre-planned procedures. Proper protective equipment should be used. In case of a spill, clear the affected area, protect people, and respond with trained personnel.

PERSONAL PROTECTIVE EQUIPMENT The proper personal protective equipment for incidental releases (such as: I Liter of the product released in a well-ventilated area), use impermeable gloves (triple-gloves (rubber gloves and nitrile gloves, over latex gloves), goggles, face shield, and appropriate body

_pr-tectitn*-In-the -ent-o"--arge-4elea se-use-impermeab1e-flve~s-spec-iic-for- the material handled, chemically resistant suit and boots, and hard hat. Self-Contained Breathing Apparatus or respirator may be required where engineering controls are not adequate or conditions for potential exposure exist. When respirators are required, select NIOSH/MSHA approved based on actual or potential airborne concentrations in accordance with latest OSHA and/or ANSI recommendations.

ENVIRONMENTAL PRECAUTIONS:

Stop spill at source. Construct temporary dikes of dirt, sand, or any appropriate readily available material to prevent spreading of the material. Close or cap valves and/or block or plug hole in leaking container and transfer to another container. Keep from entering storm sewers and ditches which lead to waterways, and if necessary, call the local fire or police department for immediate emergency assistance.

CONTAINMENT AND CLEAN-UP MEASURES:

Absorb spilled liquid with polypads or other suitable absorbent materials. if necessary,'

neutralize using suitable buffering material, (acid with soda ash or base with phosphoric acid), and test area with litmus paper to confirm neutralization. Clean up with non-combustible absorbent (suchas: sand, soil, and so on). Shovel up and place all spill residue in suitable containers, dispose of at an appropriate waste disposal facility according to current applicable laws and regulations and product characteristics at time of disposal (see Section 13 - Disposal Considerations).

SECTION 7. HANDLING AND STORAGE HANDLING Use only with adequate ventilation. Do not get in eyes, on skin or clothing.

Wear OSHA Standard full face shield. Consult Safety Equipment Supplier. Wear goggles, face shield, gloves, apron & footwear impervious to material. Wash clothing before reuse, NEVER pour water into this substance. When dissolving or diluting, always add it slowly to the water.

To minimize static discharge when transferring, ensure electrical continuity by bonding and grounding all equipment. Use an inlet line diameter of at least 3.5 inches (8.9 centimeters) with a maximum flow rate of I meter/second.

STORAGE Keep separated from strong oxidants, strong acids, combustible & reducing substances, metals, food & feedstuffs. Keep cool. Keep dry. Keep in the dark. See: Section 10, (Materials to Avoid>. Do not store above 49 C/120 F. Keep container tightly closed

& upright when not in use to prevent leakage.

Wear full face shield, gloves & full protective clothing when opening or handling.

When empty, drain completely, replace bungs securely.

NONBULK: CONTAINERS:

Store containers in a cool, dry location, away from direct sunlight, sources of intense heat, or where freezing is possible. Material should be stored in secondary containers or in a -diked area, as appropriate. Store containers away from incompatible chemicals (see Section 10, Stability and Reactivity). Post warning and "NO SMOKING" signs in storage and use areas, as appropriate. Empty containers should be handled with care. Never store food, feed, or drinking water in containers which held this product.

BULK CONTAINERS:

All tanks and pipelines which contain this material must be labeled. Perform routine maintenance on tanks or pipelines which contain this product. Report all leaks immediately to the proper personnel.

Attachment NOC-AE-14003142 Page 114 of 155 UNIVAR USA INC. MSDS NO:OX76685 ISSUE DATE:2011-12-21 VERSION:010 2014-03-18 Annotation:

COMPANY IDENTITY: Univar DATE: 12/21/11 PRODUCT IDENTITY: Liquichlor 10-16% (Sodium Hypochlorite 10-16%) PAGE: 4 OF 8 SECTION 7. HANDLING AND STORAGE (CONTINUED)

TANK CAR SHIPMENTS:

Tank cars carrying this product should be loaded and unloaded in strict accordance with tank-car manufacturer's recommendation and all established on-site safety procedures.

Appropriate personal protective equipment must be used (see Section 8, Engineering Controls and Personal Protective Equipment.). All loading and unloading equipment must be inspected, prior to each use. Loading and unloading operations must be attended, at all times. Tank cares must be level, brakes must be set or wheels must be locked or blocked prior to loading or unloading. Tank car (for loading) or storage tanks (for unloading)


must be verified to be correct for receiving this rier*-to-s-t-ai~ting-the-transfer-o. product and be properly n-ch--ppe

-*~rH~e-mast---*e-verJt+ prepared, t positions, before starting transfer operations. A sample (if required) must be taken and verified (if required) prior to starting transfer operations. All lines must be blown-down and purged before disconnecting them from the tank car or vessel.

PROTECTIVE PRACTICES DURING MAINTENANCE OF CONTAMINATED EQUIPMENT:

Follow practices indicated in Section 6 (Accidental Release Measures). Make certain application equipment is locked and tagged-out safely. Always use this product in areas where adequate ventilation is provided. Collect all rinsates and dispose of according to applicable Federal, State, or local procedures.

SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION MATERIAL CAS# EINECS# TWA (OSHA) TLV (ACGIH)

Water 7732-18-5 231-791-2 None Known None Known Sodium Hydroxide 1310-73-2 - 2 mg/m3 None known Sodium Hypochlorite 7681-52-9 - None Known None Known MATERIAL CAS# EINECS# CEILING STEL(OSHA/ACGIH) HAP Sodium Hydroxide 1310-73-2 - 2 mg/m3 None Known No This product contains no EPA Hazardous Air Pollutants (HAP) in amounts > 0.1%.

RESPIRATORY EXPOSURE CONTROLS b l&ti 65ý00'su-re lmits . .iVen 51Y6Ve- .-I respiratory protection is needed, use only protection authorized in 29 CFR 1910.134, European Standard EN 149, or applicable State regulations. If adequate ventilation is not available or there is potential for airborne exposure above the exposure limits, a respirator may be worn up to the respirator exposure limitations, check with respirator equipment manufacturer's recommendations/limitations. For a higher level of protection, use positive pressure supplied air respiration protection or Self Contained Breathing Apparatus or if oxygen levels are below i9.5%or are unknown.

EMERGENCY OR PLANNED ENTRY INTO UNKNOWN CONCENTRATIONS OR IDLH CONDITIONS Positive pressure, full-face piece Self Contained Breathing Apparatus; or positive pressure, full-face piece Salf Contained Breathing Apparatus with an auxilliary positive pressure Self Contained Breathing Apparatus..

VENTILATION LOCAL EXHAUST: Necessary MECHANICAL (GENERAL): Necessary SPECIAL: None OTHER: None Please refer to ACGIH document, "Industrial Ventilation, A Manual of Recommended Practices", most. recent edition, for detailsi EYE PROTECTION:

-Splash goggles or safety glasses. Face-shields are recommended when the operation can generate splashes, sprays or mists.

HAND PROTECTION:

Wear appropriate impervious gloves for routine industrial use. Use impervious gloves for spill response, as stated in Section 6 of this SDS (Accidental Release Measures).

Attachment NOC-AE-14003142 Page 115 of 155 UNIVAR USA INC. MSDS NO:OX76685 ISSUE DATE:2011-12-21 VERSION:010 2014-03-18 Annotation:

COMPANY IDENTITY: Univar DATE: 12/21/11 PRODUCT IDENTITY: Liquichlor 10-16% (Sodium Hypochlorite 10-16%) PAGE: 5 OF 8 SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION (CONTINUED)

NOTICE: The selection of a specific glove for a particular application and duration of use in a.workplace should also take into account all relevant workplace factors such as, but not limited to: Other chemicals which may be handled, physical requirements (cut/puncture protection, dexterity, thermal protection), potential body reactions to glove materials, as well as the instructions/specifications provided by the glove supplier.

BODY PROTECTION:

Use body protection appropriate for task. Cover-all, rubber aprons, or chemical protective

.clothing made from impervious materials are generally acceptable, depending on the task.

WORK & HYGIENIC PRACTICES:

Provide readily accesslble eye wash stations &"'safety showers.

Wash at end of each workshift & before eating, smoking or using the toilet.

Promptly remove clothing that becomes contaminated. Destroy contaminated leather articles. Launder or discard contaminated clothing.

SECTION 9. PHYSICAL & CHEMICAL PROPERTIES APPEARANCE: Liquid, Clear, Yellow to Yellow-Green ODOR: Chlorine-like, Pungent ODOR THRESHOLD: 0.3 ppm (detection), for Chlorine pH (Neutrality): 12 - 14 (1%.Solution)_

MELTING POINT/FREEZING POINT: -27 C / -17 F BOILING RANGE (IBP,5.0%,Dry Point): 140 C / 284 F FLASH POINT .(TEST METHOD): Not Applicable EVAPORATION RATE (n-BUTYL ACETATE=I): Not Applicable FLAMMABILITY CLASSIFICATION: Non-Combustible LOWER FLAYUMABLE LIMIT IN AIR (% by vol): Not Applicable UPPER FLA&MABLE LIMIT IN AIR (%by vol): Not Available VAPOR PRESSURE (mm of Hg)@20 C 12 (12.5% Solution)

VAPOR DENSITY (air=l): .0.670 GRAVITY @ 68/68 F / 20/20 C:

SPECIFIC GRAVITY (Water=l): 1.17 - 1,22 POUNDS/GALLON: 9.75 - 10.20 PARTITION COEFFICIENT (n-Octane/Water): Not Available AUTO IGNITION TEMPERATURE: Not Applicable DECOMPOSITION TEMPERATURE: Not Available VOC'S (>e,44 Lbs/Sq In) : 0.0 Vol% /0.0 g/L / 0.000 Lbs/Gal TOTAL VOC'S (TVOC)*: 0.0 Vol% /0.0 g/L / 0.000 Lbs/Gal NONEXEMPT VOC'S (CVOC)*: 0.0 Vol% /0.0 g/L / 0.000 Lbs/Gal HAZARDOUS AIR POLLUTANTS (HAPS): 8.8 Wt9 /0.0 g/L / 0.000 Lbs/Gal NONEXEMPT VOC PARTIAL PRESSURE (mm of Hg Q 20 C) 0.0 Using California South Coast Air Quality Management District (SCAQMD) Rule 443.1.

SECTION 10. STABILITY & REACTIVITY STABILITY Stable under normal conditions.

CONDITIONS TO AVOID Isolate from extreme temperatures and incompatible chemicals.

MATERIALS TO AVOID Reacts violently with fire extinguishers containing water. The substance is a strong base, reacts violently with acids and is corrosive. Decomposes on heating and on contact with strong acids, (such as sulfuric acid) producing, toxic & corrosive fumes including, chlorine, phosgene, & hydrogen chloride. The. substance is a strong oxidant & reacts violently with combustible & reducing materials. Reacts with water generating sufficient heat to ignite combustible materials. Reacts violently with strong acids, causing fire &

explosion hazard. Attacks many plastics, rubber, coatings, many metals, such as aluminum,

.zinc, tin, & lead. forming flammable/explosive gas (hydrogen).

Reacts with ammonium salts to produce ammonia & causing fire hazard.

Rapidly absorbs carbon dioxide & water from the air.

Attachment NOC-AE-14003142 Page 116 of 155 UNIVAR USA INC. MSDS NO:OX76685 ISSUE DATE:2011-12-21 VERSION:010 2014-03-18 Annotation:

COMPANY IDENTITY: Univar DATE: 12/21/11 PRODUCT IDENTITY: Liquichlor 10-16% (Sodium Hypochlorite 10-16%) PAGE: 6 OF 8 SECTION 10. STABILITY & REACTIVITY (CONTINUED)

HAZARDOUS DECOMPOSITION PRODUCTS Hydrogen Chloride, Phosgene, Sodium Oxide & Hydroxide from heating.

HAZARDOUS POLYMERIZATION Will not occur.

SECTION 11. TOXICOLOGICAL INFORMATION ACUTE HAZARDS EYE & K-FKN--CON'TA-T:

Severe burns to skin, defatting, dermatitis.

Severe burns to eyes, redness, tearing, blurred vision.

Liquid can cause severe skin & eye burns. Wash thoroughly after handling.

INHALATION:

Severe respiratory tract irritation may occur. Vapor harmful. The applicable occupational exposure limit value should not be exceeded during any part of the working exposure.

SWALLCWING:

Harmful or fatal if swallowed.

SUBCHRONIC HAZARDS/CONDITIONS AGGRAVATED CONDITIONS AGGRAVATED:

Sodiumn Hypochlorite, a component of this product, is a sensitizer. Prolonged or repeated skin contact can result in the development of rashes, welts, and other allergy-like symptoms.

CHRONIC HAZARDS CANCER, REPRODUCTIVE & OTHER CHRONIC HAZARDS:

This product has no carcinogens listed by IARC, NTP, NIOSH, OSHA or ACGIH, as of this date,..gpreeater rqual to 0.1%. ...

MUTAGENICITY: This product is not reported to produce mutagenic effects in humans.

Human mutation data are available for Sodium Hypochlorite (a component of this product);

these data were obtained during clinical studies involving specific tissues exposed to relatively high concentrations of this substance. Mutation data, obtained during clinical studies on test animal tissues or micro-organisms are available for Potassium Hydroxide.

EMBRYOTOXICITY: This product is not reported to produce embryotoxic effects in humans.

TERATOGENICITY: This product is not reported to produce teratogenic effects in humans.

REPRODUCTIVE TOXICITY: This product is not reported to cause reproductive effects in humans.

A mutaen is a chemical which causes permanent changes "to genetic material (DNA) such that the changes will propagate through generational lines. An embrvotoxin is a chemical which causes damage to a developing embryo (such as: within the eight weeks of pregnancy in humans), but the damage does not propagate across generational lines. A teratogen is a chemical which causes damage to a developing fetus, but the damage does no-tpropagate across generational lines. A reproductive toxin is any substance which interferes in any way with the reproductive process.

MAMMALIAN TOXICITY INFORMATION SODIUM HYDROXIDE:

Eye irritancy (monkey): 1%, 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> (severe)

Eye irritancy (rabbit): 500 ml, 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> (severe)

Eye irritancy (rabbit): 1% solution (severe)

Eye irrItancy (rabbit): I .mg, 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> (severe)

Cytogenic analysis system (grasshopper parenteral): 20 mg LD50 (interperoneal, mouse): 48 mg/kg LDLo (oral, rabbit): 500 mg/kg

Attachment NOC-AE-14003142 Page 117 of 155 UNIVAR USA INC. MSDS NO:OX76685 ISSUE DATE:2011-12-21 VERSION:010 2014-03-18 Annotation:

COMPANY IDENTITY: Univar DATE: 12/21/11 PRODUCT IDENTITY: Liquichlor 10-16% (Sodium Hypochlorite l1-16%) PAGE: 7 OF 8 SECTION 11. TOXICOLOGICAL INFORMATION (CONTINUED).

MAMMALIAN TOXICITY INFORMATION (CONTINUED)

SODIUM HYPOCHLORITE:

Eye effects (Adult Rabbit): Moderate irritation effects.

Microsomal Mutageniticity Assay (Salmonella typhimunium): 1 mg/plate Cytogenetic Analysis (Human): Lymphocyte, ie0 ppm/24 hours.

TDLo, Oral (woman): I g/kg, Central nervous system effects, blood pressure effects TDLo, Intravenous (Man): 45 mg/kg, Pulmonary system , LD50 (Oral, Mouse): 5800 mg/kg S -SECT1ON-12ECOLOGICAL-INFORt4AT-ION ALL WORK PRACTICES MUST BE AIMED AT ELIMINATING ENVIRONMENTAL CONTAMINATION.

EFFECT OF MATERIAL ON PLANTS OR ANIMALS:

This product may be harmful or fatal to plant and animal life if released into the environment. Refer to Section 11 (Toxicological Information) for further data on the effects of this product's components on test animals.

EFFECT OF MATERIAL ON AQUATIC LIFE:

LCSB (Bluegill sunfish): 2.90 mg/L/96 hours LC50 (Pimephales promelas): 1.40 mg/L/96 hours LCS5 (Oncorhynchus mykiss): 0.90 mg/L/0.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> The substance is toxic to aquatic organisms.

The substance may be hazardous in the environment, Special attention should be given to water organisms.

MOBILITY IN SOIL Mobility of this material has not been determined.

DEGRADABILITY This product is completely biodegradable.

-ACCUMULAT ION - ................ . . .....

Bloaccumulation of this product has not been determined.

SECTION 13. DISPOSAL CONSIDERATIONS Processing, use or contamination may change the waste management options.

Recycle / dispose of observing national, regional, state, provincial and local health, safety & pollution laws. If in doubt, contact appropriate agencies.

SECTION 14. TRANSPORT INFORMATION IF > 625 LB / 284 KG OF. THIS PRODUCT IN I CONTAINER, IT EXCEEDS THE "RQ" OF SODIUM HYPOCHLORITE.

DOT SHIPPING NAME: UN1791, Hypochlorite Solutions, B, PG-Irl DRUM LABEL: (CORROSIVE)

EMERGENCY RESPONSE GUIDEBOOK NUMBER: 154

Attachment NOC-AE-14003142 Page 118 of 155 UNIVAR USA INC. MSDS NO:OX76685 ISSUE DATE:201 1-12-21 VERSION:010 2014-03-18 Annotation:

COMPANY IDENTITY: Univar DATE: 12/21/11 PRODUCT IDENTITY: OX76685 PAGE: 8 OF 8 SECTION 15. REGULATORY INFORMATION EPA REGULATION:

SARA SECTION 311/312 HAZARDS: Acute Health All components of this product are on the TSCA list, This material contains no known products restricted under SARA Title III, Section 313 in amounts greater or equal to 1%.

SARA TITLE III INGREDIENTS CAS# EINECS# WT% (REG.SECTION) RQ(LBS)

Sodiun Hypochlorite 7681-52-9 - <,16 (311,312) lee Sodium Hydroxide 1310-73-2 -. __.. ..

> 625 LB / 284 KG OF THIS PRODUCT IN 1 CONTAINER EXCEEDS THE "RQ' OF SODIUM HYPOCHLORITE.

Any release equal to or exceeding the RQ must be reported to the National Response Center (800-424-8802) and appropriate state and local regulatory agencies as described in 40 CFR 302.6 and 40 CFR 355..40 respectively.

Failure to report may result in substantial civil and criminal penalties, State & local regulations may be more restrictive than federal regulations, STATE REGULATIONS:

CALIFORNIA PROPOSITION 65: This product contains no chemicals known to the State of California to cause cancer & reproductive toxicity.

U.S. STATE REGULATED COMPONENTS: (HAZARDOUS SUBSTANCE LISTS):

OMPONENT AK CA F.L IL KS MA HI MN Sodium Hypochlorlte No No No Yes No No No No Sodium Hydroxide Yes Yes Yes Yes Yes Yes Yes Yes
OMPONENT MO NJ ND PA RI TX WV WI Sodium Hypochlorite No Yes Yes No No No No No Sodium Hydroxide Yes Yes Yes Yes Yes Yes Yes Yes INTERNATIONAL REGULATIONS The components of this product are listed on the chemical inventories of the

... .Qllowngcountries.:.,-...- ...... ... ...........

Australia (AICS), Canada (DSL, NDSL), China (IECSC), Europe (EINECS, ELINCS)J Japan (METI/CSCL, MHLW/ISHL), South Korea (KECI), New Zealand (NZIoC),

Philippines (PICCS), Switzerland (SWISS), Taiwan (NECSI), USA (TSCA).

CANADA: WORKPLACE HAZARDOUS MATERIALS INFORMATION SYSTEM (WHMIS)

  • C: Oxidizing Material.

D2B: Irritating to skin / eyes.

E: Corrosive Material.

SECTION 16. OTHER INFORMATION HAZARD RATINGS:

HEALTH .(NFPA): 3, HEALTH (HMIS): 3, FLAMMABILITY: 8, REACTIVITY: 1 (Personal Protection Rating to be supplied by user based on use conditions.)

This information is intended solely for the use of individuals trained in the NFPA & HMIS hazard rating systems.

EMPLOYEE TRAINING See Section 2 for Risk & Safety Statements. Employees should be made aware of all hazards of this material (as stated in this SDS) before handling it.

Attachment NOC-AE-14003142 Page 119 of 155 Univar USA Inc Material Safety Data Sheet For Additional Information contact. MSDS Coordinator during business hours, Pacific time: (425) 889-3400 Notice Univar USA Inc. ("Univar") expressly disclaims all express or implied warranties of merchantability and fitness for a particular purpose, with respect to the product or information provided herein, and shall under no circumstances be liable for Incidental or consequential damages.

Do not use ingredient information and/or ingredient percentages In this MSDS as a product specification. For product specification Information refer to a product specification sheet and/or a certificate of analysis. These can be obtained from your local Univar sales office.

All information appearing herein is based upon data obtained from the manufacturer and/or recognized technical sources. While the Information is believed to be accurate, Univar makes no representations as to its accuracy or sufficiency. Conditions of use are beyond Univar's control and therefore users are responsible to verify this data under their own operating conditions to determine whether the product is suitable for their particular purposes and they assume all risks of their use, handling, and disposal of the product, or from the publication or use of, or reliance upon, Information contained herein.

This information relates only to the product designated herein, and does not relate to its use in combination with any other material or in any other process

Attachment NOC-AE-14003142 Page 120 of 155 SAFETY DATA SHEET , -/b (

.P4LCO PRODUCT NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER(S)

(800) 424-9300(24 Hours) CHEMTREC I 1. I CHEMICAL PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME: NALCO 1359 PLUS APPLICATION : CORROSION INHIBITOR COMPANY IDENTIFICATION: Nalco Company 1601 W. Diehl Road Naoerville. Illinois 60563-1198 EMERGENCY TELEPHONE NUMBER(S): (800) 424-9300 (24 Hours) CHEMTREC NFPA 704MIHMIS RATING HEALTH: 313 FLAMMABILITY: 0/0 INSTABILITY: 010 OTHER:

0 = Insignificant 1 =Slight. 2 =Moderate 3 =High 4 =Extreme * =Chronic Health Hazard I 2. .I COMPOSITIONIINFORMATION ON INGREDIENTS II Our hazard evaluation has Identified the following chemical substance(s) as hazardous. Consult Section 15 for the nature of the hazard(s).

Hazardous Substance(s) CAS NO  %(w/w)

Sodium Nitrite 7632-00-0 10.0- 30.0 Sodium Metaborate 7775-19-1 5.0- 10.0 13..HA.ADS...N I C.T...... .. --.

~EMERGENCY OVERVIEW" DANGER Toxic if swallowed. Irritating to eyes and skin. Contains sodium nitrite. Substances In the product can lead to the formation of methemoglobin. Unborn children are particularly sensitive to methemoglobinemia.

Do not get in eyes, on skin, on clothing. Do not take internally. Use with adequate ventilation. In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. After contact with skin, wash Immediately with plenty of water.

Wear suitable protective clothing.

Not flammable or combustible. May evolve oxides of nitrogen (NOx) under fire conditions. Ifproduct is allowed to dry, the sodium nitrite is an oxidizing agent and can Initiate the combustion of other materials.

PRIMARY ROUTES OF EXPOSURE:

Eye, Skin HUMAN HEALTH HAZARDS - ACUTE:

EYE CONTACT: .

Irritating, and may injure eye tissue if not removed promptly.

Nalco Company 1601 W. Diehl Road -Naperville, Illinois 60563-1198 - (630)305-1000 For additional copies of an MSDS visit wwv.nalco.com and request access.

1110 I

Attachment NOC-AE-14003142 Page 121 of 155 SAFETY DATA SHEET SNALCO NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER(S)

(800) 424-9300(24 Hours) CHENTREC SKiN CONTACT:

Can cause mild Irritation.

INGESTION:

Not a likely route of exposure. Large exposures may be fatal. Ingestion of sodium nitrite can cause methemoglobinemia which can lead to cyanosis and possible death. Pregnant women and their fetuses are particularly sensitive to the effects of methemoglobinemia.

IN HALATIO N : -- -_ _-U ___ ___ ____ ___ ___ __r Not alikely route otexposure. Aeri6tsoTs r til nTa-fle t"pe pT t-6ra6cf ct.

SYMPTOMS OF EXPOSURE:

Acute :

A review of available data does not identify any symptoms from exposure not previously mentioned.

Chronic A review of available data does not identify any symptoms from exposure not previously mentioned, AGGRAVATION OF EXISTING CONDITIONS:

Sodium Nitrite. Pregnant women are particularly sensitive to methemoglobinemia.

HUMAN HEALTH HAZARDS - CHRONIC:

Repeated ingestion of small amounts of sodium nitritecauses drops In blood pressure, rapid pulse, headaches and visual disturbances. Itmay also reactwith organic amines in the body to form carcinogenic nitrosamines.

14. 1FIRST AID MEASURES EYE CONTACT:

.. . .... .. . .flImmediately t eye flush ush ln gT-G thid alawith thdoi. . . ..15......

water for at.. least minutes while ho!ding

.............. ... .. ..open.

...... eyelids Ifirritation persists, repeat SKINCONTACT:

Immediately flush with plenty of water for at least 15 minutes. Ifsymptoms persist, call a physician, INGESTION:

Do not induce vomiting without medical advice. Ifconscious, washout noutlh and give water to drink. Get Immediate medical attention.

INHALATION:

Remove to fresh air, treat symptomatically. If symptoms develop, seek medical advice.

NOTE TO PHYSICIAN:

Based an the individual reactions of the patient, the physician's judgement should be used to control symptoms and clinical condition. Measures against circulatory shock, respiratory depression and convulsions may be needed.

Nalco Company 1601 W. Diehl Road - Naperville, Illinois 60563-1198- (630)305.1000 For additional copies of an MSDS visit www.nalco.com and request access.

2110

Attachment NOC-AE-14003142 Page 122 of 155 SAFETY DATA SHEET PRODUCT

- ýtNImA LCO ` NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER(S) 1800) 424-9300 (24 Hours) CHEMTREC I S. I FIRE FIGHTING MEASURES II

15. 1 FIRE FIGHTING MEASURES FLASH POINT: None EXTINGUISHING MEDIA:

Not expected to bum. Use extinguishing media appropriate for surrounding fire.

FIRE AND EXPLOSION HAZARD:.

Not flammable or combustibNI7 May evolve oxides.of nitrogen (NOx) under tire conditions. Ifproduct is allowed to dry, the sodium nitrite Is an.oxidizing agent and can initiate the combustion of other materials.

SPECIAL PROTECTIVE EQUIPMENT FOR FIRE FIGHTING:

In case of fire, wear a full face positive-pressure.self contained breathing apparatus and protective suit.

16. 1 ACCIDENTAL RELEASE MEASURES PERSONAL PRECAUTIONS:

Restrict access to area as appropriate until clean-up operationsi are complete. Ensure clean-up it conducted by trained personnel only. Ventilate spill area if possible. Do not touch spilled material. Stop or reduce anyleaks if Itis safe to do so. Use personal protective equipment recommended In Section 8 (Exposure Controls/Personal Protection). Notify appropriate government, occupational health and safetyand environmental authorities.

METHODS FOR CLEANING UP:

SMALL SPILLS:. Soakup spill with absorbent material, Place residues in a suitable, covered, properly labeled container. Wash affected area. LARGE SPILLS: Contain liquid using absorbent material, by digging trenches or by diking. Reclaim Into recovery or salvage drums or tank truck for proper disposal. Wash site of spillage thoroughly with water. Contact an approved waste hauler for disposal of contaminated recovered material. Dispose of material in

..... .6MP It66WMiiia hii i d* ffi*

-eddi-S i6- 13-(D 1*Zsa

- *d e tikoi .............

ENVIRONMENTAL PRECAUTIONS:

Do not contaminate surface.water.

7i HANDLING ANDSTORAGE HANDLING:

Do not get in eyes, on sklnj on clothing. Do not take internally. Use with adequate ventilation. Do not breathe vapors/gases/dust. Keep the containers closed when not In use. Have emergency equipment (for fires, spills, leaks, etc.) readily available. Ensure all containers are labeled.

STORAGE CONDITIONS:

Store the containers tghUy closed. Store insuitable labeled containers, Store separately from acids. Store separately from reducing agents.

1 8. 1 EXPOSURE CONTROLS/PERSONAL PROTECTION OCCUPATIONAL EXPOSURE LIMITS:

This product does not contain any substance that has an established exposure limit.

Nalco Company 1601 W. Diehl Road 'Naperville, Illinois 60563-1198, (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.

3110

Attachment NOC-AE-14003142 Page 123 of 155 SAFETY DATA SHEET PRODUCT NANALCO NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER(S)

(B00) 424-$300 (24 Hours) CHEMTREC ENGINEERING MEASURES:

General ventilation is recommended.

RESPIRATORY PROTECTION:

Respiratory protection is not normally needed.

HAND PROTECTION:

...... __WbembandliLngthispruo.dctthe-useDLchemicalgaunhLetss-rcommaended.L*beachcice-oLwork-glove-depends.on work conditions and what chemicals are handled, but we have positive experience under light handling conditions using gloves made from Neoprene PVC or nitrite Gloves should be replaced immediately If signs of degradation are observed. 'Breakthrough time not determined as preparation, consult PPE manufacturers.

SKIN PROTECTION:

When handling this product, the use of overalls, a chemical resistant apron and rubber boots is recommended. A full slicker suit Is recommendedif gross exposure is possible.

EYE PROTECTION:

Wear chemical splash goggles.

HYGIENE RECOMMENDATIONS:

Use good work and personal hygiene practices to avoid exposure. Keep an eye wash fountain available. Keep a safety shower available, If clothing is contaminated, remove clothing and thoroughly wash the affected area. Launder contaminated clothing before reuse, Always wash thoroughly after handling chemicals, When handling this product never eat, drink or smoke.

HUMAN EXPOSURE CHARACTERIZATION:

Based on our recommended product application and personal protective eq.uipment the potentialhuman exposure Is:.

S...Mod edrte - - .. .'........

19. 1PHYSICAL AND CHEMICAL PROPERTIES

.PHYSICAL STATE Liquid APPEARANCE Light yellow ODOR SPECIFIC GRAVITY 1.305 @ 72 -F 122.2 -C DENSITY 10.84 lb/gal SOLUBILITY IN WATER Complete pH (100 %) >= 11.4 VISCOSITY Max 7 cps @ 73 °F 122.8 *C FREEZING POINT <.-50 OF 1-45.5 QC VAPOR PRESSURE Same as water Note: These physical properties are typical values for this product and are subject to change.

Nalco Company 1601 W. Diehl Road

  • Napervltle, Illinois 60563-1198 * (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.

4/10

Attachment NOC-AE-14003142 Page 124 of 155 SAFETY DATA SHEET NALC0 N PRODUCT NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER(S)

(800) 424.9300(24 Hours) CHEMTREC

10. STABILITY AND REACTIVITY STABILITY:

Stable under normal conditions.

HAZARDOUS POLYMERIZATION; Hazardous polymerization will not occur.

  • CONDIrONSWTO-AvOlD.

Freezing temperattres. Do not allow product to evaporate to dryness. Dried product residue can act as an oxidizer.

MATERIALS TO AVOID:

Contact with reducing agents (e.g. hydrazine, sulfites, sulfide, aluminum or magnesium dust) may generate heat, fires, explosions and tOXic vapors. Do not mix with amines, Sodium nitrite can react with certain amines to produce N-nitrosamines, Many of which are cancer-causing agents to laboratory animals. Contact with strong acids (e.g.

sulfuric, phosphoric, nitric, hydrochloric, chromic, sulfonlc) may generate heat, splattering or boiling and toxic vapors.

HAZARDOUS DE(OOMPOSITION PRODUCTS :.

Under fire conditiolis: Oxides of nitrogen

11. 1ToXI-_LOGICAL INFORMATION No toxicity studies have been conducted on this product.

SENSITIZATION :

This product Is not expected to be a sensitizer.

None of the substances In this product are listed as carcinogens by the International Agency for Research on Cancer (IARC), the Nationcl Toxicology Program (NTP) or the American Conference of Governmental Industrial. Hygienists (ACGIH)..

HUMAN HAZARD CHARACTERIZATION:

Based on bur hazard characterization, the potential human hazard is: High

12. 1ECOL-GICAL INFORMATION ECOTOXICOLOGICAL EFFECTS:

No toxicity studies have been-conducted on this product.

MOBILITY:

The environmental fate was estimated using a level III fugacity model embedded in the EPI (estimation program ineace) Suite TM, provided by the US EPA. The Model assumes a steady state condition between the total input and output. The level III model does not require equilibrium between the.defined media. The informtation provided is intended to give th user a general estimate of the environmental fate of this productunder the defined conditions of the models, NA0o Co'mpany 1601 W. Diehl Road Naperville, Illinois 60563.1198 ' (630)305-1000 For additional copies of an MSDS visit wvw.nalco.com and request access.

5110

Attachment NOC-AE-14003142 Page 125 of 155 SAFETY DATA SHEET

)4NOA LL'0 PRODUCT NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER(S)

(800) 424-9300 (24 Hours) CHEMTREC If released Into the environment this material Is expected to distribute to the.air, water and scil/sediment in the approximate respective percentages; Air WtrSoil/Sediment

<5% 30-50% 50-70%

The portion in water is expected to be soluble or dispersible.

ENVIRONMENTA.-TAZ'AR DAN 1EXPO SURE-CH AP,-TER IZAT-10 Based on our hazard characterization, the potential environmental hazard is: Moderate Based on our recommended product application and the product's characteristics, the potential environmental exposure Is: High Ifreleased Into the environment, see CERCLA/SUPERFUND in Section 15.

I 13. I DISPOSAL CONSIDERATIONS I If this product becomes a waste, it could meet the criteria of a hazardous waste as defined by the Resource Conservation and Recovery Act (RCRA) 40 CFR 261, Before disposal, Itshould be determined If the waste meets the criteria of a hazardous waste, Hazardous Waste: D002 Hazardous wastes must be transported by e licensed hazardous waste transporter and disposed of or treated in a properly licensed hazardous waste treatment, storage, disposal or recycling facility. Consult local, state, and federal regulations for specific requirements.

i RTRANSPORTINFORMATION .- .."----.-

The Information In this section is for reference only and should not take the place of a shipping paper (bill of lading) specific to an order. Please note that the proper Shipping Name I Hazard Class may vary by packaging, properties, and mode of transportation. Typical Proper Shipping Names oethis product are as follows.

LAND TRANSPORT:

Proper Shipping Name: CORROSIVE LIQUID, TOXIC, N.O.S Technical Name(s): SODIUM NITRITE UN/ID No: UN 2922 Hazard Class - Primary: 8 Hazard Class - Secondary: 6.1 Packing Group: III Flash Point: None Reportable Quantity (per package): 430 lbs RQ Component: SODIUM NITRITE AIR TRANSPORT (ICAOIIATA):

Proper Shipping Name: CORROSIVE LIQUID. TOXIC, NO.S Nalco Company 1601 W. Diehl Road - Naperville, Illinois 60563-1198 (-630)305-1000 For additional copies of an MSDS visit www,nalco.com and request access.

6110

Attachment NOC-AE-14003142 Page 126 of 155 SAFETY DATA SHEET

~N A LUC= 0 PRODUCT NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER(S)

(800) 424-9300(24 Hours) CHEMTREC Technical Name(s): SODIUM NITRITE UNIID No: UN 2922 Hazard Class - Primary: 8 Hazard Class -. Secondary: 6.1 Packing Group: III Reportable Quantity (per package): 430 lbs RQ Component: SODIUM NITRITE MARINE TRANSPORT (IMDG/IMO):

P-operShipping-Name : -CORROSIVE-LIQUID;-TOXIG,-.G-.S Technical Name(s): SODIUM NITRITE UNIID No: UN 2922 Hazard Class - Primary: 8 Hazard Class - Secondary: 6.1 Packing Group: III I 15. I REGULATORY INFORMATION I This section contains additional Information that may have relevance to regulatory compliance. The information in this section is for reference only. It Is not exhaustive, and should no' be relied Upon to take the place of an individualized compliance or hazard assessment. Nalco accepts no liability for the use of this information.

NATIONAL REGULATIONS, USA:

OSHA HAZARD COMMUNICATION RULE, .29 CFR 1910.1200:

Based on our hazard evaluation, the following substance(s) in this product is/are hazardous and the reason(s) islare shown below.

So.Ndium.Nt.te ..:-TargtO.Qrga-Enffe L-;.I.doey,Target-Organ:Effect ,Nervous~systemTarget:Organ.Effect:.,:-loodI.;

Sodium Metaborate.: Irritant CERCLA!SUPERFUNDO 40 CFR 302:

This product contains the following Reportable Quantity (RO) Substance. Also listed is the RO for the product.

  • RO.Substance Sodium Nitrte B2q 430 Ibis SARANSUPERFUND AMENDMENTS AND REAUTHORIZATION ACT OF 1986 (TITLE III) - SECTIONS 302, 311, 312t AND 313:

SECTION 302 - EXTREMELY HAZARDOUS SUBSTANCES (40 CFR 355):

This product does not contain substances listed in Appendix A and B as an Extremely Hazardous Substance.

SECTIONS 311 AND 312 - MATERIAL SAFETY DATA SHEET REQUIREMENTS (40 CFR 370):

Our hazard evaluation has found this product to be hazardous. The product should be reported under the following indicated EPA hazard categories:

X Immediate. (Acute) Health HaZard Nalco Company 1601 W. Diehl Road

  • Naperville, Illinois 60563-1198 - (630)305-1000 For additional copies of an MSDS visil vvw.nalco.com and request access.

7110

Attachment NOC-AE-14003142 Page 127 of 155 SAFETY DATA SHEET 7' PIRODUCT

ýq N'AALC(eO% NALCO 1359 PLUS EMERGENCY TELEPHONE NUMSER(S)

(800) 424-9300 (24 Hours) CHEMTREC X Delayed (Chronic) Health Hazard Fire Hazard Sudden Release of Pressure Hazard Reactive Hazard Under SARA 311 and 312, the EPA has established threshold quantities for the reporting of hazardous chemicals, The current thresholds are: 500 pounds or the threshold planning quantity (TPQ), whichever is lower, for extremely hazardous substances and 10,000 pounds for all other hazardous chemicals.

_-SECLQFj_3J2,_._.L'O.FTQXJC.. HEM.CALS_..CER,371) "

This product contains the following substance(s), (with CAS # and % range) which appear(s) on the List of Toxic Chemicals Hazardous Substance(s) CAS NO Sodium Nitrite 7632-00-0 10.0- 30.0 TOXIC SUBSTANCES CONTROL ACT (TSCA):

The substances in this preparation are Included on or exempted from. the TSCA 8(b) Inventory (40 CFR 710)

FEDERAL WATER POLLUTION CONTROL ACT, CLEAN WATER ACT, 40 CFR 401A 5 /formerly Sec, 307,40 CFR 116.4 Iformerly Sec. 311:

This product contains the following substances listed in the regulation. Additional components may be unintentionally present at trace levels.

Substance(s)s Citations

" Sodium Nitrite Sec. 311

" Sodium Hydroxide 11Ozone Depleting Substances) :

Substances listed under this regulation are not Intentionally added or expected to be present In this product. Listed components may be present at trace levels.

CALIFORNIA PROPOSITION 65:

Substances listedunder California Proposition 65 are not Intentionally added or expected to be present In this product.

MICHIGAN CRITICAL MATERIALS:

Substances listed under this regulation are not intentionally added or expected to be present in this product. Listed components may be present at trace levels.

STATE RIGHT TO KNOW LAWS The following substances are disclosed for compliance with State Right to Know Laws:

Sodium Nitrite 7632-00-0 Nalco Company 1601 W. Diehl Road -Naperville, Illinois 60563-1198 - (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.

8110

Attachment NOC-AE-14003142 Page 128 of 155 SAFETY DATA SHEET.

SNALCO PRODUCT NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER(S)

(800) 424-9;300 (24 Hours) CHEMTREC Threshold Limit Values for Chemical Substances and Physical Agents and Biological Exposure Indices, American Conference of Governmental Industrial Hygienists, OH., (Arlel InsightTU CD-ROM Version), Arnel Research Corp.,

Bethesda, MD.

Hazardous Substances Data Bank, National Library of Medicine, Bethesda, Maryland (TOMES CPS"" CD-ROM Version), Micromedex, Inc., Englewood, CO.

IARC Monographs on the Evaluation of [he Carcinogenic Risk of Chemicals to Man, Geneva: World Health Organl tio-rlilet to--A- e-c Integrated Risk Information System, U.S. Environmental Protection Agency, Washington, D.C. (TOMES CPSTm CD-ROM Version),

Micromedex, Inc., Englewood, CO.

Annual Report on Carcinogens, National Toxicology Program, U.S. Department of Health and HumanServices, Public Health Service.

Title 29 Code of Federal Regulations, Part 1910, Subpart Z, Toxic and Hazardous Substances. Occupational Safety and Health Administration (OSHA), (Arlel Insightm CD-ROM Version), Ariel Research Corp., Bethesda, MD.

Registry of Toxic Effects of Chemical Substances, National Institute for Occupational Safety and Health, Cincinnati, OH, (TOMES CPSTM CD-ROM Version), Micromedex, Inc., Englewood, CO.

Ariel InsightTu (An integrated guide to industrial chemicals covered under major regulatory and advisory programs),

North American Module, Western European Module, Chemical Inventories Module and the Generics Module (Ariel

......... rC o~q p ._- - -- w . .... . ................

The Teratogen Information System, University of Washington, Seattle, WA (TOMES CPSTM CD-ROM Version),

Micromedex, Inc., Englewood, CO.

Prepared By: Product Safety Department Date Issued: 03/0112012 Version Number: 2.2 Nalco Company 1601 W. Diehl Road - Naperville, Illinois 60563-1198 - (630)305-1000 For additional copies of an MSDS visit wvw.nalco.com and request access.

10/10

Attachment NOC-AE-14003142 Page 129 of 155 SAFETY DATA SHEET A4.NALCU`ý PRODUCT NALCO 1359 PLUS

.EMERGENCY TELEPHONE NUMBER(S)

(800) 424-9300 (24 Hours) CHEMTREC INTERNATIONAL CHEMICAL CONTROL LAWS:

CANADIAN ENVIRONMENTAL PROTECTION ACT (CEPA):

The substances in this preparation are listed on the Domestic Substances List (DSL), are exempt, or have been reported in accordance with the New Substances Notification Regulations, AUSTRALIA All substances in this product comply with the National Industrial Chemicals Notification &Assessment Scheme (NICNAS).

EUROPE The substances in this preparation have been reviewed for compliance with the EINECS or ELINCS Inventories.

JAPAN All substances In this product comply with the Law Regulating the Manufacture and Importation Of Chemical Substances and are listed on the.Existing and New Chemical Substances list (ENCS).

KOREA All substances In this product comply with the Toxic Chemical Control Law (TCCL) and are listed on the Existing Chemicals List (ECL)

PHILIPPINES All substances In this product comply with the RepublicAct 6969 (RA 6969) and are listed on the Philippines Inventory of Chemicals &Chemical Substances (PICGS).

116. 1OTHER INFORMATION Due to our commitment to Product Stewardship, we have evaluated the human and environmental hazards and exposures sef te a si r6--.Kwvb chirimt*iid~the c. .- -p general risk. This Information should provide assistance for your own risk management practices. We have evaluated our product's risk as follows:

'The human risk Is: Moderate

  • The environmental risk Is: Moderate Any use inconsistent with our recommendations may affect the risk characterization. Our sales representative will assist you to determine ifyour product application Is consistent with our recommendations. Together we can Implement an appropriate risk management process.

This product material safety data sheet provides health and safety information. The product Is to be used in applications consistent with our product literature. Individuals handling this product should be informed of the recommended safety precautions and should have access to this Information. For any other uses, exposures should be evaluated so that appropriate handling practices and training programs can be established to Insure safe workplace operations. Please consult your local sales representative for any further information.

REFERENCES Nalco Company 1601 W. Diehl Road - Naperville, Illinois 60563-1198 - (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.

9/10

Attachment NOC-AE-14003142 Page 130 of 155 SAFETY DATA SHEET AWNALCO PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)

(800) 424-9300 (24 Hours) CHEMTREC

11. 1CHEMICAL PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME: NALCO 19H APPLICATION: OXYGEN SCAVENGER COMPANY IDENTIFICATION: Nalco Company 1601 W. Diehl Road 60563-1198 EMERGENCY TELEPHONE NUMBER(S): (800) 424-9300 (24 Hours) CHEMTREC NFPA 704MIHMIS RATING HEALTH: 2/2' FLAMMABILITY: III INSTABILITY: 0/0 OTHER:

0 = Insignificant 1 = Slight 2 = Moderate 3 = High 4 = Extreme Chronic Health Hazard

12. 1 COMPOSITION/INFORMATION ON INGREDIENTS Our hazard evaluation has Identified the following chemical substance(s) as hazardous. Consult Section 15 for the nature of the hazard(s).

Hazardous Substance(s) CAS NO  % (w/w)

Hydrazine :302-01-2 30.0- 60.0

--j-1HAZARDS IDENTIFICATION-- ........ .......

    • EMERGENCY OVERVIEW**

DANGER This product contains hydrazine which is a suspect carcinogen. Extreme health hazard. Toxic by inhalation, in contact with skin and if swallowed. Irritating toskin. Risk of serious damage to eyes. May cause sensitization by skin contact. Very toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment.

Do not get in eyes, on skin, on clothing. Do not take internally. Use with adequate ventilation. Keep container tightly closed and in a well-ventilated place. If respiratory symptoms develop, remove to fresh air, rest, treat symptomatically. Get medical attention. In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. After contact with skin, wash immediately with plenty of water. Use a mild soap if available.

Wear a face shield, Wear chemical resistant apron, chemical splash goggles, impervious gloves and boots.

Hydrazine can ignite spontaneously in air in contact with wood, cloth, earth, or other organic materials. Heat or contact with strong acid can result Inthe generation of flammable hydrogen gas. May evolve oxides of nitrogen (NOx) under fire conditions. May evolve ammonia under fire conditions. May evolve toxic gases or fumes under fire conditions. Empty product. containers may contain product residue. Do not pressurize, cut, heat, weld, or expose containers to flame or other sources of ignition. Contact with reactive metals (e.g. aluminum) may result In the generation of flammable hydrogen gas.

Nalco Company 1601 W. Diehl Road - Naperville, Illinois 60563-1198 - (630)305-1000 For additional copies of an MSDS visit wAw.nalco.com and request access.

1/13

Attachment NOC-AE-14003142 Page 131 of 155 SAFETY DATA SHEET AVNALCO PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)

(800) 424-9300 (24 Hours) CHEMTREC PRIMARY ROUTES OF EXPOSURE:

Eye, Skin HUMAN HEALTH HAZARDS - ACUTE:

EYE CONTACT:

Severe!y irritating. If not removed promptly, will Injure eye tissue and may result in permanent eye damage.

SKIN CONTACT:

Prolonged or frequently repeated skin contact may cause. allergic reactions in some individuals. Toxic in contact wilh skin. May causesevereit-on or tissue damage depending on the length of exposure and the type of first aid administered.

INGESTION:

Not a likely route of exposure. Toxic if swallowed. May cause mucosal damage.

INHALATION:

Not a likely route of exposure. Toxic by inhalation. Vapors extremely Irritating to eyes and respiratory tract. Can cause pulmonary edema. May cause liver and kidney disorder andlor damage.

SYMPTOMS OF EXPOSURE:

Acute:

A review of available data does not Identify any symptoms frorm exposure not previously mentioned.

Chronic:

A review of available data does not identify any symptoms from exposure not previously mentioned.

AGGRAVATION OF EXISTING CONDITIONS:

Preexisting eye, skin, and respiratory conditions may be aggravated.

HUMAN HEALTH HAZARDS - CHRONIC:

This product contains hydrazine. The International Agency for Research on Cancer(IARC) has evaluated hydrazine, and found it to be a possible human carcinogen (Group 28) based on sufficient animal data and inadequate human data. Oral administration of hydrazine has produced lung and liver tumors in mice and rats and mammary tumors in mice. Inhalation of hydrazine has produced nasal tumors in rats.

14. 1 FIRST AID MEASURES EYE CONTACT:

Get immediate medical attention. PROMPT ACTION IS ESSENTIAL IN CASE OF CONTACT. Immediately flush eye with water for at least 15 minutes while holding eyelids open.

SKIN CONTACT:

Get Immediate medical attention. Immediately flush with plenty of water for at least 15 minutes. For a large splash, flood body under a shower. Remove contaminated clothing. Wash off affected area immediately with plenty of water.

Contaminated clothing, shoes, and leather goods must be discarded or cleaned before re-use.

Nalco Company 1601 W. Diehl Road - Naperville, Illinois 60563-1198 - (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.

2/13

Attachment NOC-AE-14003142 Page 132 of 155 SAFETY DATA SHEET PWNALCO PRODUCT NALCOO 19H EMERGENCY TELEPHONE NUMBER(S)

(800) 424-9300 (24 Hours) CHEMTREC INGESTION:

DO NOT INDUCE VOMITING. If conscious, washout mouth and give water to drink. Get immediate medical attention.

INHALATION:

Remove to fresh air, treat symptomatically. Get medical attention.

NOTE TO PHYSICIAN:

Probable mucosal damage may contraindicate the use of gastric lavage. Based on the individual reactions of the patient, the physician's judgement should be used to control symptoms and clinical condition.

5. FIRE FIGHTING MEASURES FLASH POINT: > 230 F/1 > 110 'C (PMCC)

EXTINGUISHING MEDIA:

Not expected to bum. Use extinguishing media appropriate for surrounding fire.

FIRE AND EXPLOSION HAZARD:

Hydrazine can ignite spontaneously in air in contact with wood, cloth, earth, or other organicmaterials. Heat or contact with strong acid can result in the generation of flammable hydrogen gas, May evolve oxides of nitrogen (NOx) under fire conditions. May evolve ammonia under fire conditions. May evolve toxic gases or fumes under fire conditions.

Empty product containers may contain product residue. Do not pressurize, cut, heat., weld, or expose containers to flame or other sources of ignition. Contact with reactive metals (e.g. aluminum) may result in the generation of flammable hydrogen gas.

SPECIAL:PROTECTIVE EQUIPMENT FOR FIRE FIGHTING:

In case of fire, wear a full face positive-pressure self contained breathing apparatus and protective suit.

6. ACCIDENTAL RELEASE MEASURES PERSONAL PRECAUTIONS:

Restrict access to area as appropriate until clean-up operations are complete. Use personal, protective equipment recommended In Section 8 (Exposure Controls/Personal Protection). Stop or reduce any leaks if it is safe to do so.

Ventilate spill area if possible. Remove sources of ignition. Ensure clean-up is conducted by trained personnel only.

Do not touch spilled material. Have emergency equipment (for fires, spills, leaks, etc.) readily available. Notify appropriate government, occupational health and safety and environmental authorities.

METHODS FOR CLEANING UP.

SMALL SPILLS: Do not clean up spills with sawdust, cotton waste or other combustible absorbent materials. Create a dike or trench to contain material. Dilute spilled material to about 10% hydrazine with water. Neutralize the diluted hydrazineby slowly adding a 5-8% calcium hypochlorite or sodium hypochlorite (bleach) solution until all the hydrazine has been reacted. Steam and nitrogen gas will be evolved. DO NOT ADD DRY CALCIUM OR SODIUM HYPOCHLORITE TO A HYDRAZINE SPILL. A VIOLENT REACTION MAY RESULT. The neutralized material may be absorbed using clay, sand or commercial absorbent. Shovel reclaimed liquid and absorbent into recovery or salvage drums for disposal, Refer to CERCLA Section 15. Contact of the unneutralized product with certain clays may lead to hydrazine decomposition and release of ammonia. Contact an approved waste hauler for disposal of contaminated Nalco Company 1601 W. Diehl Road

  • Naperville, Illinois 60563-1198 * (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.

3/13

Attachment NOC-AE-14003142 Page 133 of 155 SAFETY DATA SHEET N4 NALC0 PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)

(800) 424-9300 (24 Hours) CHEMTREC recovered material. LARGE SPILLS: Dike to prevent further movement. Dispose of material in compliance with regulations indicated in Section 13 (Disposal Considerations).

ENVIRONMENTAL PRECAUTIONS:

Do not contaminate surface water.

17. 1HANDLING AND STORAGE HANDLING:

Do not get In eyes, on skin, on clothing. Do not take internally. Use with adequate ventilation. Do not breathe vaporsigasesldust. Keep the containers closed when not in use. Have emergency equipment (for fires, spills, leaks, etc.) readily available. Ensure all containers are labeled. Do not mix with acids. Do not use, store, spill or pour near heat, sparks or open flame. Handle the material under an inert atmosphere of nitrogen or argon.

STORAGE CONDITIONS:

Store the containers tightly closed. Store separately from oxidizers. Store away from organic materials. Store in suitable labeled containers. Store away from heat and sources of ignition. Keep away from light, direct sunlight.

Empty spaces in tanks must be filled by inert atmosphere.

SUITABLE CONSTRUCTION MATERIAL:

Polypropylene, Polyethylene, Stainless Steel 304, Stainless Steel 316L, Compatibility with Plastic Materials can vary; we therefore recommend that compatibility is tested prior to use.

UNSUITABLE CONSTRUCTION MATERIAL:

Copper, Brass, Aluminum Ef8--iEXPOSURE CONTRO*LOIPES*iiNC--IPROTECTION OCCUPATIONAL EXPOSURE LIMITS:

Exposure guidelines have not been established for this, product, Available exposure limits for the substance(s) are

shown below.

Substance(s) CatagofV: ppm Unit Hydrazine ACGIHITWA 0.01 ACGII-tSkln' OSHA ZI/PEL 1 1.3 0SHA Z1/SkhV*

  • Can be absorbed through the skin.

ENGINEERING MEASURES:

General ventilation Is recommended. Use local exhaust ventilation If necessary to control airborne mist and vapor.

Nalco Company 1601 W. Diehl Road - Naperville, Illinois 60563-1198 * (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.

4113

Attachment NOC-AE-14003142 Page 134 of 155 SAFETY DATA SHEET PRODUCT

~N ALCO NALCO 19H EMERGENCY TELEPHONE NUMBER(S)

(800) 424-9300(24 Hours) CHEMTREC RESPIRATORY PROTECTION:

Where concentrations in air may exceed the limits given in this section or when significant mists, vapors, aerosols, or dusts are generated, an approved air purifying respirator equippedwith suitable filter cartridges Is recommended.

consult the respirator / cartridge manufacturer data to verify the suitability of specific devices. In event of emergency of planned entry Into unknown concentrations a positive pressurefull-facepiece SCBA should be used. Ifrespiratory protection is required, institute a complete respiratory protection program including selection, fit testing, training, maintenance and inspection.

HAND PROTECTION:

When handling this product, the use of chemical gloves is recommended. The choice of work glove depends on work conditionsand what chemicals are handled. Please contact the PPE manufacturer fo" advice on what type of glove material may be suitable. Gloves should be replaced immediately if signs of degradation are observed.

SKIN PROTECTION:

Wear chemical resistant apron, chemical splash goggles, impervious gloves and boots. A full slicker suit is recommended ifgross exposure is possible.

EYE PROTECTION:

Wear a face shield with chemical splash goggles.

HYGIENE RECOMMENDATIONS:

Use good work and personal hygiene practices to avoid exposure. Keep an eye wash fountain available. Keep a safety shower available. Ifclothing is contaminated, remove clothing and thoroughly wash the affected area. Launder contaminated clothing before reuse. Always wash thoroughly after handling chemicals. When handling this product never eat, drink or smoke.

I 9. I PHYSICAL AND CHEMICAL PROPERTIES I APPEARANCE Colorless ODOR Ammonlacal SPECIFIC GRAVITY 1.03 @ 60 F115.6 -C DENSITY 8.56 Ib/gal SOLUBILITY IN WATER Complete pH (100/%) 12.5 pH (1 %) 10.1.- 10.7 VISCOSITY 2.0 cps @ 60 =F 115.6 *C FREEZING POINT -85 IF -65 'C BOILING POINT 228 OF / 108.9 OC VAPOR PRESSURE 22mmHg @ 77°F125°C Note: These physical properties are typical values for this product and are subject to change.

Nalco Company 1601 W. Diehl Road

  • Naperville, Illinois 60563-1198 - (630)305-1000 For additional copies of an MSDS visit www.nalco.coni and request access.

5/13

Attachment NOC-AE-14003142 Page 135 of 155 SAFETY DATA SHEET P NALCO PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)

(800) 424-9300,(24 Hours) CHEMTREC

11. 1STABILITY AND REACTIVITY__

STABILITY:

Stable if kept under conditions specified in Section 7, HANDLING AND STORAGE.

HAZARDOUS POLYMERIZATION:

Hazardous polymerization will not occur.

____C_ ONJ0[SJDcLTO_ lD-Q 1-___

Extremes of temperature Heat and sources of ignition Including static discharges.

Keep at temperature not exceeding 123 TF MATERIALS TO AVOID:

Acids Contact with strong acids (e.g. sulfuric, phosphoric, nitric, hydrochloric, chromic, suffonic) may generate heat, splattering or boiling and toxic vapors. Contact with strong oxidizers (eg. chlorine, peroxides, chromates, nitric acid, perchlorate, concentrated oxygen, permanganate) may generate heat, fires, explosions and/or toxic vapors. Organic materials Gives off hydrogen by reaction with metals. Avoid contact with metal oxides such as those of iron, copper, lead, manganese and molybdenum. Such contact may lead to decomposition.

HAZARDOUS DECOMPOSITION PRODUCTS:

Under fire conditions: Oxides of nitrogen, ammonia, Flammable gases/vapors

11. TOXICOLOGICAL INFORMATION The following results are for the product.

.................. *,.C .IE.Q8* L _TOXl Q.LTY *

.Species:

z a

LD50: 185 mg/kg Test Descriptor: Product ACUTE DERMAL TOXICITY:

Species: Rabbit LD50: 420 mg/kg Test Descriptor: Product ACUTE INHALATION TOXICITY:

Species: Rat LC50: 2.1 mg/I (4 hrs)

Test Descriptor; Product SENSITIZATION:

May cause sensitization by skin contact.

Nalco Company 1601 W. Diehl Road Napervilie, Illinois 60563-1198 - (630)305-1000 For additional copies of an MSDS visit vvww.nalco.com and request access.

6/13

Attachment NOC-AE-14003142 Page 136 of 155 SAFETY DATA SHEET r-4NA LCO PRODUCT NALCO 19H EMERGENCY.TELEPHONE NUMBER(S)

(800) 424-9300 (24 Hours) CHEMTREC CARCINOGENICITY:

This product contains hydrazine, The International Agency for Research on Cancer(IARC) has evaluated hydrazine, and found it to be a possible human carcinogen (Group 2B) based on sufficient animal data and inadequate human data, MUTAGENICITY:

An ingredient in this product has shown positive results in a screening test for mutagenicity.

- 4IHUMAN-,AZARD-CHARACTERIZAT4.0N Based on our hazard characterization, the potential human hazard is: High 112. 1 ECOLOGICAL INFORMATION ECOTOXICOLOGICAL EFFECTS:

The following results are for the product.

Acute Fish Results _

Species Exposure Test Type Value Test Descriptor Bluegill Sunfish 96 hrs LC50 4.2 mg/I Product Rainbow Trout 96 hrs LC50 4.3 mg/I Product Gold Orfe 96 hrs LC50 0.75 mg l Product ACUTE INVERTEBRATE RESULTS:

Species Exposure Test Type Value Test Descriptor Daphnia magna 48 hrs LC50 0.46 mg/1 Product PERSISTENCY AND DEGRADATION:

The organic portion of this preparation is expected to be readily biodegradable.

MOBILITY:

The environmental fate was estimated using a level III fugacity model embedded in the EPI (estimation program interface) Suite TM, provided by the US EPA. The model assumes a steady state condition between the total input and output. The level lIlImodel does not require equilibrium between the defined media. The information provided is intended to give the user a general estimate of the environmental fate of this product under the defined conditions of the models.

If released Into the environment this material Is expected to distribute to the air, water and soil/sediment in the approximate respective percentages; Air Water. Soil/Sediment 30 - 50% 50- 70%

The portion in water is expected to be soluble or dispersible.

Nalco Company 1601 W. Diehl Road Naperville, Illinois 60563-1198 - (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access, 7/13

Attachment NOC-AE-14003142 Page 137 of 155 SAFETY DATA SHEET NNALCO PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)

(800) 424-9300 (24 Hours) CHEMTREC BIOACCUMULATION POTENTIAL This preparation or material Is not expected to bloaccumulate.

ENVIRONMENTAL HAZARD AND EXPOSURE CHARACTERIZATION Based on our hazard characterization, the potential environmental hazard is: High If released Into the environment, see CERCLA/SUPERFUND in Section 15.

I 13. I DISPOSAL CONSIDERATIONS I If this product becomes a waste, it could meet the criteria of a hazardous waste as defined by the Resource Conservation and Recovery Act (RCRA) 40 CFR 261, Before disposal, it should be determined if the waste meets the criteria of a hazardous waste.

Hazardous Waste: D002, U133 Hazardous wastes must be transported by a licensed hazardous waste transporter and disposed of or treated in a properly licensed hazardous waste treatment, storage, disposal. or recycling facility. Consult local, state, and federal regulations for specific requirements. Contact of the unneutralized product with certain clays may lead to hydrazine decomposition and release of ammonia.

I 4. I TRANSPORT INFORMATION I The information in this section is for reference only and should not take the place of a shipping paper (bill of lading) specific to an order. Please note that the proper Shipping Name I Hazard Class may vary by packaging, properties, and mode of transportation. Typical Proper Shipping Names for this product are as follows.

7--:r.-Thee pres-ence-uaanyR.Q -mmp-nedepoe:uant UtShEPkand :D(),imthLsproduct-cause s-lttoe regulated with an additional description of RO for road, or as a class 9 for road and air, ONLY when the net weight in the package exceeds the calculated RQ for the product.

LAND TRANSPORT:

Proper Shipping Name: HYDRAZINE, AQUEOUS SOLUTION Technical Name(s):

UN/ID No: UN 3293 Hazard Class - Primary: 6.1 Packing Group: III Flash Point: > 110'°C /,> 230 °F Reportable Quantity (per package): 3 lbs RQ Component: HYDRAZINE I AIR TRANSPORT (ICAO!IATA):

Nalco Company 1601 W. Diehl Road Naperville, Illinois 60563-1198 * (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.

8113

Attachment NOC-AE-14003142 Page 138 of 155 SAFETY DATA SHEET

"'NALCO PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)

(800) 424-9300 (24 Hours) CHEMTREC The presence of an RQ component (Reportable Quantity for U.S. EPA and DOT) In this product causes it to be regulated with an additional description of RO for road, or as a class 9 for road and air, ONLY when the net weight in.

the package exceeds the calculated RQ'for the product.

Proper Shipping Name: HYDRAZINE, AQUEOUS SOLUTION Technical Name(s):

UN/ID No: UN 3293 Hazard Class - Primary: .6.1 Packing Group: Ill

[ifJ t*

RQ Component: HYDRAZINE MARINE TRANSPORT (IMDG/IMO):

Proper Shipping Name: HYDRAZINE, AQUEOUS SOLUTION Technical Name(s):

UN/ID No: UN 3293 Hazard Class - Primary: 6,1 Packing Group: IHI Marine Pollutant: HYDRAZINE

  • Note: This product is regulated as a Marine Pollutant when shipped by Rail, Highway (in bulk quantities), or Air (if no other hazard class applies), and when shipped by water in all quantities.

I 15. 1REGULATORY INFORMATION I

-,.--.T~his~section..contalns.additional~inforrnaUon~that-nmy-ay erlvnd~o ]a(y z-bnom p-nh

..... is or refer*nce' It is not exhaustive, and should not be relied upon to take the place of an Individualized compliance or hazard assessment. Nalco accepts no liability for the use of this information.

NATIONAL REGULATIONS, USA:

OSHA HAZARD COMMUNICATION RULE, 29 CFR 1910.1200:

  • Based on our hazard evaluation, the following substance(s) in this product isWare hazardous and the reason(s) islare

.shown below.

Hydrazine : Cancer suspect agent (refer to Section 3), Corrosive, Dermal Sensitizer CERCLA/SUPERFUND, 40 CFR 302:

  • This product contains the following Reportable Quantity (RQ) Substance. Also listed is the RQ for the product. Ifa reportable quantity of product is released, it requires notification to the NATIONAL RESPONSE CENTER, WASHINGTON, D.C. (1-800-424-8802).

RQ Substance Hydrazine 3 lbs Nalco Company 1601 W. Diehl Road . Naperville, Illinois 60563-1198- (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.

9/13

Attachment NOC-AE-14003142 Page 139 of 155 SAFETY DATA SHEET N"NALCO PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(SY (800) 424-9300 (24 Hours) CHEMTREC I

SARAISUPERFUND AMENDMENTS AND REAUTHORIZATION ACT OF 1986 (TITLE t11)- SECTIONS 302, 311, 312, AND 313:

SECTION 302 - EXTREMELY HAZARDOUS SUBSTANCES (40 CFR 355):

This product contains the following substance(s) which is listed in Appendix A and B as an Extremely Hazardous Substance. Listed below are the statutory Threshold Planning Quantity (TPQ) for the substance(s) and the Reportable Quantity (RO) of the product. If a reportable quantity of product is released, it requires notification to your State Fmerg ny-Response-Commisso--Y-ou-may-also-be-require:l~o-notifythe.Naona .Response.Center.See CERCLAISUPERFUND, above.

Extremely Hazardous Substance TPQ R.Q Hydrazine 1,000 lbs 3 lbs SECTIONS 311 AND 312 -MATERIAL SAFETYDATA SHEET REQUIREMENTS (40 CFR 3701':

Our hazard evaluation has found this product to be hazardous. The product should be reported under the following indicated EPA hazard categories:

X Immediate (Acute) Health Hazard X Delayed (Chronic) Health Hazard Fire Hazard Sudden Release of Pressure Hazard Reactive Hazard Under SARA 311 and 312, the EPA has established threshold quantities for the reporting of hazardous chemicals.

The current thresholds are: 500 pounds or the threshold planning quantity (TPQ), whichever is lower, for extremely hazardous substances and 10,000 pounds for all other hazardous chemicals.

SECTION 313 - LIST OF TOXIC CHEMICALS (40 CFR 372):

This product contains the following substance(s), (with CAS # and % range) which appear(s) on the List of Toxic Chemicals Hazardous Substance(s) CAS NO Hydrazine 302-01-2 30.0-60.0 TOXIC SUBSTANCES CONTROL ACT (TSCA):

The substances in this preparation are included on or exempted from the TSCA 8(b) Inventory (40 CFR 710)

FOOD AND DRUG ADMINISTRATION (FDA) Federal Food, Drug and Cosmetic Act:

When use situations necessitate compliance with FDA regulations, this product is acceptable under: 21 CFR 173.310 Boiler Water Additives The following limitations apply:

Maximum dosage Limitation ZERO PPM as product in the steam Nalco Company 1601 W. Diehl Road - Naperville, Illinois 60563w1198 * (630)305-1000 For additional copies of an MSDS visit wvwv.nalco.com and request access.

10113

Attachment NOC-AE-14003142 Page 140 of 155 SAFETY DATA SHEET PRODUCT ii r4 NALCO NALCOR 19.H EMERGENCY TELEPHONE NUMBER(S)

(800) 424-9300 (24 Hours) CHEMTREC Steam produced may be used in contact with any food type, defined under 21 CFR 170.3, which includes milk or milk products.

NSF NON-FOOD COMPOUNDS REGISTRATION PROGRAM (former USDA List of Proprietary Substances &

Non-Food Compounds) :

NSF Registration number for this product is : 062465 This product is acceptable for treating boilers or steam lines where steam produced may contact edible products and/or cooling systems where the treated water may not contact edible products in and around food processing areas FEDERAL WATER POLLUTION CONTROL ACT, CLEAN WATER ACT, 40 CFR 401.15 / formerly Sec. 307,40 CFR 116.4/ formerly Sec. 311 :

Substances.listed under this regulation are not intentionally added or expected to be present in this product. Listed components may be present at trace levels.

CLEAN AIR ACT, Sec. 112 (Hazardous Air Pollutants, as amended by 40 CFR 63), Sec. 602 (40 CFR 82, Class I and II Ozone Depleting Substances) :

This product contains the following substances listed in the regulation. Additional components may be unintentionally present at trace, levels.

Substance(s) Citations

. Hydrazine Sec. 112

CALIFORNIA PROPOSITION 65:

This product contains the following substances which require warnin,9 under California Proposition 65. Additional

.........

  • componentsr may b- h-ffie-f -lypresenteattracetlevels le.ve . ............ . ..

Substance(s) Concentration EFFECTS

  • Hydrazine <60% Causes Cancer MICHIGAN CRITICAL MATERIALS:

This product contains the following substances listed in the regulation. Additional components may be unintentionally present at trace levels.

Hydrazine STATE RIGHT TO KNOW LAWS:

The following substances are disclosed for compliance with Stale Right to Know Laws:

Hydrazine 302-01-2 Nalco Company 1601 W. Diehl Road . Naperville, Illinois 60563-1198 * (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.

11/13

Attachment NOC-AE-14003142 Page 141 of 155 SAFETY DATA SHEET NNALCO PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)

(800) 424-9300 (24 Hours) CHEMTREC INTERNATIONAL CHEMICAL CONTROL LAWS:

CANADIAN ENVIRONMENTAL PROTECTION ACT (CEPA):

The substance(s) in this preparation are included In or exempted from the Domestic Substance List (DSL).

AUSTRALIA All substances in this product comply with the National Industrial Chemicals Notification & Assessment Scheme (NICNAS)., .

CHINA All substances In this product comply with the Provisions on the Environmental Administration of New Chemical Substances and are listed on or exempt from the Inventory of Existing Chemical Substances China (IECSC).

EUROPE The substances in this preparation have been reviewed for compliance with the EINECS or ELINCS inventories.

JAPAN All substances in this product comply with the Law Regulating the Manufacture and importation Of Chemical Substances and are listed on the Existing and New Chemical Substances list (ENCS).

KOREA All substances in this product comply with the Toxic Chemical Control Law (TCCL) and are listed on the Existing Chemicals List (ECL)

PHILIPPINES All substances in this product comply with the Republic Act 6969 (RA 6969) and are listed on the Philippines Inventory

16. OTHER INFORMATION This product material safety data sheet provides health and safety information. The product Is to be used in applications consistent with our product literature. Individuals handling this product should be informed of the recommended safety precautions and should have access to this information. For any other uses, exposures should be evaluated so that appropriate handling practices and training programs can be established to insure safe workplace operations. Please consult your local sales representative for any further information.

REFERENCES Threshold Limit Values for Chemical Substances and Physical Agents and Biological Exposure Indices, American Conference of Governmental Industrial Hygienists, OH., (Arlel InsightTM CD-ROM Version), Ariel Research Corp.,

Bethesda, MD.

Hazardous Substances Data Bank, National Library of Medicine, Bethesda, Maryland (TOMES CPS'm CD-ROM Version), Micromedex, Inc., Englewood, CO.

Nalco Company 1601 W. Diehl Road

  • Naperville, Illinois 60563-1198 * (630)305-1000 For additional copies of an MSDS. visit www.nalco.com and request access.

12/13

Attachment NOC-AE-14003142 Page 142 of 155 SAFETY DATA SHEET N"NALCO PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)

(800) 424-9300 (24 Hours) CHEMTREC IARC Monographs on the Evaluation of the Carcinogenic Risk-of Chemicals to Man, Geneva: World Health Organi.za.tion, Iternaional Agency for Research on.Cancer...........................

Integrated Risk Information System, U.S. Environmental Protection Agency, Washington, D.C. (TOMES CPSTM CD-ROM Version),

Micromedex, Inc., Englewood, CO.

Annual Report on Carcinogens, National Toxicology Program, U.S. Department of Health and Human Services, Public Health Service.

Title 29 Code of Federal Regulations, Part 1910, Subpart Z, Toxic and Hazardous Substances, Occupational Safety and Health Administration (OSHA), (Ariel InsightThM CD-ROM Version), Ariel Research Corp., Bethesda, MD.

Registry of Toxic Effects of Chemical Substances, National Institute for Occupational Safety and Health, Cincinnati, OH, (TOMES CPSTM CD-ROM Version), Micromedex, Inc., Englewood, CO, AAdel InsightTM (An integrated guide to industrial chemicals covered under major regulatory and advisory programs),

North American Module, Western European Module, Chemical Inventories Module and the Generics Module (Ariel Insight TM CD-ROM Version), Ariel Research Corp., Bethesda, MD.

The Teratogen Information System, University of Washington, Seattle, WA (TOMES CPSTM CD-ROM Version),

Micromedex, Inc., Englewood, CO.

. Prepared-By-

. -Product'Safetyý-De* r--*tit. -

mr .. . . ... ............ . . ..

Date issued : 06127/2012 Version Number: 4.2 Nalco Company 1601 W. Diehl Road

  • Naperville, Illinois 60563-1198 .(630)305-1000 For additional copies of an MSDS visit www:nalco.com and request access.

13/13

Attachment NOC-AE-14003142 Page 143 of 155 (C'age 2 of 13)

DATA SHEET A4

_______SAFETY PRODUCT LCS-60 EMERGENCY TELEPHONE NUMBER(S)

(800) 424-300 (24 Hours) CHEMTREC 1: CHIEMICAL PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME: LCS-_0 APPLICATION: WATER TREATMENT COMPANY IDENTIFICATION: Nalco Company 161-WT~ieni Roacd Naperville, Illinois 60563-1198 EMERGENCY TELEPHONE NUMBER(S): (800) 424-9300 (24 Hours) CHEMTREC NFPA 704M/HMIS RATING HEALTH: 2/2 FLAMMABILITY: 0/0 INSTABILITY: 010 OTHER:


O-=-tnsignificant--l--- Slight ---2--Moderate--3-=-Righ--4-=-Extreme-'*-Chronic-Health-Hazard

12. 1 COMPOSITIONIINFORMATION ON INGREDIENTS Our hazard evaluation has Identified the following chemical substance(s) as hazardous. Consult Section 15 for the nature of the hazard(s).

Hazardous Substance(s) CAS NO  % (wlw)

Sodium Nitrite 7632-00-0 5.0- 10.0 Sodium Tetraborate

....... 0..-"

. ...i 3. ! zA..... . . . .. . . . . . ... .......... . .......... ..... . . . . ..........

1330-43-4 1.0 - 5,0

13. 1HAZ-ARDS IDENTIFICATION
    • EMERGENCY OVERVIEW-DANGER Toxic if swallowed, Contains sodium nitrite. Substances In the product can lead to the formation of methemoglobin.

Unborn children are particularly sensitive to methemoglobinemia.

Do not get in eyes, on skin, on clothing. Do not take Internally. Use with adequate ventilation. In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. After contact with skin, wash immediately with plenty of water.

Wear suitable protective clothing.

May evolve oxides of nitrogen (NOx) under fire conditions. If product is allowed to dry, the sodium nitrite is an oxidizing agent and can initiate the combustion of other materials, Not flammable or combustible.

P RIMARY'ROUTESOFEXPOSUR.:

Eye, Skin HUMAN HEALTH HAZARDS -ACUTE:

EYE CONTACT:

Can cause mild to moderate irritation.

Nalco Company 1601 W. Diehl Road' Naperville, Illinois 60563-1198 * (630)305-1000 For additional copies of an MSDS visit www.nalcocom and request access.

1/10 9

Attachment NOC-AE-14003142 Page 144 of 155 i~age 3 :! 13)

____ ___ SAFETY DATA SHEET -_

PRODUCT

~NALCO LS6 EMERGENCY TELEPHONE NUMBER(S)

(BO)424-9300 (24 Hours) CHEMTREC SKIN CONTACT:

May cause Irritation with prolonged contact INGESTION:

Not a likely route of exposure. Large exposures may be fatal. Ingestion of sodium nitrile can cause methemoglobinemia which can lead to cyanosis and possible death. Pregnant women and their fetuses are parIcurayysetTv-e-ft*o-the e*rectsdf methemoglobinemia.

INHALATION:

Not a likely route of exposure. Aerosols or product mist may irritate the upper respiratory tract.

AGGRAVATION OFEXISTING CONDITIONS:

Sodium Nitrite. Pregnant women are particularly sensitive to methernoglobinemia.

HUMAN HEALTH HAZARDS - CHRONIC.:

Repeated ingestion of small amounts of sodium nitrite causes drops in blood pressure, rapid pulse, headaches and visual disturbances. It may also react with organic amines In the body to form carcinogenic nitrosamines.

14. 1 FIRST AID MEASURES SKIN CONTACT:

Immediately flush with plenty of water for at least 15 minutes. If symptoms develop, seek medical advice.

INGESTION:

Get Immediate medical attention. Do not Induce vomiting without medical advice. If conscious, washout mouth and

-give--wat-er-to.drink;....... .... . .

INHALATION:

Remove to fresh air, treat symptomatically. Get medical attention.

NOTE TO PHYSICIAN:

Based on the individual reactions of the patient, the physician's judgement should be used to control symptoms and clinical condition. Measures against circulatory shock, respiratory depression and convulsions may be needed.

15. 1FIRE FIGHTING MEASURES FLASH POINT: None EXTINGUISHING MEDIA :

Not expected to burn. Use extinguishing media appropriate for surrounding fire.

FIRE AND EXPLOSION HAZARD :

May evolve oxides of nitrogen (NOx) under fire conditions. Ifproduct is allowed todry, the sodium nitrite is an oxidizing agent and can initiate the combustion of other materials. Not flammable or combustible.

SPECIAL PROTECTIVE EQUIPMENT FOR FIRE FIGHTING:

In case of fire, wear a full face positive-pressure self contained breathing apparatus and protective suit.

Nalco Company 1601 W. Dihl Road

  • Naperville. Illinois 60563-1198 - (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.

2110

Attachment NOC-AE-14003142 Page 145 of 155 (Page 4 of 13)

.N04 SAFETY DATA SHEET PRODUCT

  • - LCS-60
  • EMERGENCY TELEPHONE NUMBER(S)

(800)424-9300 (24 Hours) CHEMTREC

6. 'ACCIDENTAL RELEASE MEASURES PERSONAL PRECAUTIONS:

Restrict access to area as appropriate until clean-up operations are complete. Use personal protective equipment recommended in Section 8 (Exposure Controls/Personal Protection). Stop or reduce any leaks Ifit is safe to do so.

Keep people away from and upwind of spill/leak. Ventilate spill area if possible. Ensure clean-up Is conducted by trained personnel only. Do not touchIoLfediateidaLtJaiwemnegency-equipmenL(for.fires~spillsr.eaksretc.)-readily available, Notify appropriate government, occupational health and safety and environmental authorities.

METHODS FOR CLEANING UP:

SMALL SPILLS: Soak up spill with absorbent material. Place residues in a suitable, covered, property labeled


container.-Wash-afected-aa.-LARGE-SP-LLS:--Contain liquid-using absorbent-material'-by-digginig~tenches~orby -

diking. Reclaim into recovery or salvage drums or tank truck for proper disposal. Wash site of spillage thoroughly with water. Contact an aoproved waste hauler fordisposal of contaminated recovered material. D.ipose of material in compliance with regulations Indicated in Section 13 (Disposal Considerations). Do not allow product to evaporate to dryness.

ENVIRONMENTAL PRECAUTIONS:

Prevent material from entering sewers or waterways., Spilled product may pose a risk to the aquatic ecosystem if released., If drains, streams, sil or sewers become contaminated, notify local authority.

17. HANDLING AND STORAGE HANDLING:

Do not take internally. Use with adequate ventilation. Do not breathe vapors/gases/dust. Do not get in eyes, on skin, on.clothing, Have emergency equmeT (for fires, spills eaks. etc.) readily av*giable., sur4alLcgnjes ar..

STORAGE CONDITIONS:

Store In suitable labeled containers. Store the containers tightly closed. Store away from organic chemicals and other oxidizable materials, reducing agents, acids and alkalis.

SUITABLE CONSTRUCTION MATERIAL:

Shipping and long term storage compatibility with construction materials can vary; we therefore recommend that compatibility is tested prior to use.

18. EXPOSURE CONTROLSIPERSONAL PROTECTION OCCUPATIONAL EXPOSURE LIMITS:

Exposure guidelines have not been established for this product. Available exposure limits for the substance(s) are shown below.

Substance(s) Category; ppm mg/m3 Non-Standard Unit Borates, Tetra, Sodium Salts - Anhydrous (Inhalable ACGIHITWA 2 fraction.)

ACGIH/STEL 6 Nalco Company 1601 W. Diehl. Road

  • Naperville. Illinois 60563-1198 * (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access:

3/10

Attachment NOC-AE-14003142 Page 146 of 155 (Page 5 of 13)

SAFETY DATA SHEET

!PRODUCT.

.. NALCO iLCs-60 EMERGENCY TELEPHONE NUMBER(S)

(800) 424-9300 (24 Hours) CHEMTREC ENGINEERING MEASURES:

General ventilation Is recommended.

-RESPIRATORY PROTECTION:

Resplratorv protection is not normally needed. Where o eithis~seio_

or when significant mists, vapors, aerosols, or dusts are generated, an approved air purifying respirator equipped with suitablefilter cartridges is recommended. Consult the respirator / cartridge manufacturer data to verify the suitability of specific devices. In event of emergency or planned entry into unknown concentrations a positive pressure, full-facepiece SCBA should be used. If respiratory protection Is required, institute a complete. respiratory protection program including selection, fit testing, training, maintenance and inspection.

HAND PROTECTION:

When handling this product, the use of chemical gloves Is recommended. The choice of work glove depends on work conditions and what chemicals are handled. Please contact the PPE manufacturer for advice on what type of glove material may be suitable. Gloves should be replaced Immediately if signs of degradation are observed.

SKIN PROTECTION:

Wear standard protective clothing.

EYE PROTECTION:

Wear chemical splash goggles.

HYGIENE RECOMMENDATIONS:


.U ............. -se-g-od-work-and-p

  • safety-showr-vai~lable,-If:*J!h**qjýcotminatedemyeqrgndtruhyas:haetdaa-Lner conta minatod-clothing:before-reuse.-Always-wash thoroughly-aafter-handling-chemicals-When-handling.this-product never.eatj drinkeor smoke.

I 9. I PHYSICAL AND CHEMICAL PROPERTIES PHYSICAL STATE Liquid APPEARANCE Clear Light yellow ODOR None SPECIFIC GRAVITY 1.076. @ 77 "F / 25 "C DENSITY 8.96 lb/gal SOLUBILITY IN WATER Complete pH (100 %) 8-9 VAPOR PRESSURE Same as water VOC CONTENT 0.0 % EPA Method 24

___Note:Ihese-chysicaboro~ertiesArelyicaLvalues-for-hisrcwductand-are-sublcieo-tchanne.

Nalco Company 1601 W. Diehl Road - Naperville, Illinois 60563-1198 * (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.

4/10

Attachment NOC-AE-14003142 Page 147 of 155 (2g of 13)

SAFETY DATA SHEET I II i i I II ',

PRODUCT 7NALCO LCS-60 EMERGENCY TELEPHONE NUMBER(S)

(800) 424-9300 (24 Hours) CHIEMTREC 110. I STABILITY AND REACTIVITY I STABILITY:

Stable under normal conditions.

HAZARDOUS POLYMERIZATION:

Hazardous polymerization will not occur.

CONDITIONS TO AVOID:

Freezing temperatures.

MATERIALS-TO-AVOID4 Contact with reducing agents (e.g. hydrazine, sulfites, sulfide, aluminum or magnesium dust) may generate heat, fires, explosions and toxic vapors. Do not mix with amines. Sodium nitrite can react with certain amines to produce N-nitrosamines, many of which are cancer-causing agents to laboratory animals. Contact with strong acids (e.g.

sulfuric, phosphoric, nitric, hydrochloric, chromic, sulfonic) may generate heat, splattering or boiling and toxic vapors.

HAZARDOUS DECOMPOSITION PRODUCTS:

Under fire conditions: Oxides of nitrogen, Oxides of sodium

11. 1 TOXICOLOGICAL INFORMATION No toxicity studies have been conducted on this product.

SENSITIZATION:

This product is not expected to be a sensitizer.

-.- CA -CRRCINO'GENI C t'- : C None of the substances in this product are listed as carcinogens by the International Agency for Research on Cancer (IARC), the National Toxicology Program (NTP) or the American Conference of Governmental Industrial Hygienists' (ACGIH).

TERATOGENICITY AND EMBRYOTOXICITY:

Experimental animal studies with sodium nitrite have shown reproductive effects in the offspring of treated parents.

These effects are not transmissible.

112. I ECOLOGICAL INFORMATION I ECOTOXICOLOGICAL EFFECTS:

The following results are for the product.

ACUTE FISH RESULTS:

s1cies Exposure LC50 Test Descriptor Rainbow Trout 96 hrs 20 m ACUTE INVERTEBRATE RESULTS:

Species Exposure LC50 I EC50 I Test Descriptor Nalco Company 1601 W. Diehl Road - Naperville, Illinois 60563-1198 - (630)305-1000 For additional copies. of an MSDS visit www.nalco.com and request access.

5/10

Attachment NOC-AE-14003142 Page 148 of 155 (page 7 of 13)

NANALCO EMERGENCY lELEPHONE NUMBER(S)

(800) 424-9300 (24 Hours) CHEMTREC Daphnia magna 48 hrs 340m 2t0m mI MOBILITY:

The environmental fate was estimated using a level III fugacity model embedded in the EPI (estimation program interface) Suite TM, provided by the US EPA. The model assumes a steady state condition between the total input and output. The level III model does not require equilibrium between the defined media. The Information provided is intended to give the user a general estimate of the environmental fate of this product under the defined conditions of the models.

If released into the environment this material is expected to distribute to the air. water and soillsediment in the approximate respective percentages;

<5% 30,-50% 50 -70%_

The portion in water is expected to be soluble or dispersible.

BIOACCUMULATION POTENTIAL This preparation or materal Is not expected to bloaccumulate.

If released Into the environment, see CERCLA/SUPERFUND in Section 15.

13. 1DISPOSAL CONSIDERATIONS

-ILthis-product-become-sa~wate*-Lis-not-a`*azardous-wasta-as~delined-by-the.Resource*Conservation-and.Recovery-Act (RCRA) 40 CFR 261, since it does not have the characteristics of Subpart C, nor is it listed under Subpart 0.

............. A"-a non-ha-zarddlis-*w~ste-*jtT- -of-sb5]Fcf-1-o-TT:!--aElg~a 6nh nsl tate-o r-lct rgu *

  • toa ..................

handling, treatment or disposal requirements. For disposal, contact a properly licensed waste treatment, storage, disposal or recycling facility.

114. 1TRANSPORT INFORMATION The information in this section is for reference only and should not take the place of a shipping paper (bill of lading) specific to an order. Please note that the proper Shipping Name / Hazard Class may vary by packaging, properties.

and mode of transportation. Typical Proper Shipping Names for this product areas follows.

The presence of an RO component (Reportable Quantity for U.S. EPA and DOT) in this product causes'it lobe regulated vAth an additional description of RO for road, or as a clars 9 for road and air, ONLY when the net weight in the package exceeds the calculated RO for the product.

LAND TRANSPORT:

Proper Shipping Name: ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S.

Technical Name(s): SODIUM NITRITE UN!ID No: UN 3082 Hazard Class - Primary: 9 Packing Group: III Nalco Company 1601 W. Diehl Road

  • Naperville, Illinois 60563-1198 * (630)305-1000 For additional copies of an MSOS visit www.nalcocom and request access.

6110

Attachment NOC-AE-14003142 Page 149 of 155 (Page 8 of 13)

SAFETY DATA SHEET PRODUCT

~NALCO LCS-60 ,

EMERGENCY TELEPHONE NUMBER(S)

(800) 424-9300 (24 Hours) CHIEMTREC Flash Point:....... N6ne .......

Reportable Quantity (per package): 1,050 lbs RQ Component: SODIUM NITRITE AIR TRANSPORT (ICAO/IATA):

The presence of an RQ component (Reportable Quantity for U.S. EPA and DOT) in this product causes it to be regulated with an additional description of RO for road, or as a class 9 for road and air, ONLY when the net weight in

- -the-pockag-xceeds-the-cafcuated'RQ-foth-ro-dar -

Proper Shipping Name: ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S.

Technical Name(s): SODIUM NITRITE UNJID No: UN 3082 Hazard Class - Primary: 9 Packing Group: III Reportable Quantity (per package): 1,050 lbs RO Component: SODIUM NITRITE MAR1 NE-TTRSORPORT7IMY G'IMO) :

Proper Shipping Name: _PRODUCT IS NOT REGULATED DURING

_________________--TRAN* PO-RTATIUON 115S. I REGULATORY INFORMATION I I

This section contains additional information that may have relevance to regulatory compliance. The information in this

. ..m-piane-for hazard assessment. Nalco accepts no liability for the use of this information.

NATIONAL REGULATIONS, USA:

OSHA HAZARD COMMUNICATION RULE, 29 CFR 1910.1200:


ased-on-our-hazard-evaluat~onTthe-follovving-substance(s)-irrt his prodact-is/are-hazardowsand-thr-mason(s)l s/are-shown below.

Sodium Nitrite: Target Organ Effect - Kidney, Target OrganEffect - Nervous system, Target Organ Effect - Blood Sodium Tetraborate: Exposure Limit CERCLA/SUPERFUND, 40 CFR 302:

This product contains the following Reportable Quantity (RO) Substance. Also listed is the RO for the product. If a reportable quantity of product is released, it requires notification to the NATIONAL RESPONSE CENTER, WASHINGTON, D.C. (1-800-424-8802).

RO Substance RQ Sodium Nitrite 1,050 Ibs Nalco Company 1601 W. DiehlI Road- Naperville. Illinois 60563-1198 - (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.

7/10

Attachment NOC-AE-14003142 Page 150 of 155 (Page 9 of 13)

SAFETY DATA SHEET

.*NALCO PRODUCT LCS-60 EMERGENCY TELEPHONE NUMBER(S)

(800)424-9300(24 Hours) CHEMTREC SARA/SUPERFUND AMENDMENTS AND REAUTHORIZATION ACT OF 1986 (TITLE III) - SECTIONS 302, 311, 312, AND 313:

SECTION 302 - EXTREMELY HAZARDOUS SUBSTANCES (40 CFR 355):

This product does not contain substances listed in Appendix A and B as an Extremely Hazardous Substance.

SECTIONS 311 AND 312 - MATERIAL SAFETY DATA SHEET REQUIREMENTS (40 CFR 370):

Our hazar-e-5---t-0-51ion- nas found this product to be hazardous. Theproduct should be reported under the following indicated EPA hazard categories:

X Immediate (Acute) Health Hazard flDrhvp~d fChronink H*.*hh H*-zird Fire Hazard Sudden Release of Pressure Hazard Reactive Hazard Under SARA 311 and 312, the EPA has established threshold quantities for the reporting of hazardous chemicals.

The current thresholds are: 500 pounds or the threshold planning quantity (TPQ), whichever is lower, for extremely hazardous substances and 10,000 pounds for all other hazardous chemicals.

SECTION 313 - LIST OF TOXIC CHEMICALS (40 CFR 372):

This product contains the following substance(s), (with CAS # and % range) which appear(s) on the List of Toxic Chemicals

_'1"-'M ,.f-Nt. ____________-___-

Sodium Nitdte 7632-00-0 5.0-10.0

_3 ....

"TOXIC-SUBSTANCES CONTROLA-,CT-(TSCA)

The substances in this preparation are included on or exempted from the TSCA 8(b) Inventory (40 CFR 710)

FEDERAL WATER POLLUTION CONTROL ACT, CLEAN WATER ACT. 40 CFRA401.15 / formerly Sec. 307.40 CFR 116.4/ formerly Sec. 311 :

This product contains the following substances listed in the regulation. Additional components may be unintentionally present at trace levels.

I Substance(s) I Citations

. Sodium Nitdte Sec. 311 CLEAN AIR ACT, Sec. 112 (Hazardous Air Pollutants, as amended by 40 CFR 63), Sec. 602 (40 CFR 82, Class Iand II Ozone Depleting Substances):

Substances listed under this regulation are not Intentionally added or expected to be present in this product. Listed components may be present at trace levels.

CALIFORNIA PROPOSITION 65:

Substances listed under California Proposition 65 are not intentionally added or expected to be present in this product.

Nalco Company 1601 W. Diehl Road

  • Naperville, Illinois 60563-1198 * (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.

8/10

Attachment NOC-AE-14003142 Page 151 of 155 1o of 1tl 13)

SAFETY DATA SHEET A4 PRODUCT.

~NALCO ~4. --

EMERGENCY TELEPHONE NUMBER(S)

.(800) 424-9300 (24 Hours) CHEMTREC MICHIGAN CRITICAL MATERIALS:

Substances listed under this regulation are not intentionally added or expected to be present in this product. Listed components may be present at trace levels.

STATE RIGHT TO KNOW LAWS:

The following substances are disclosed for compliance with State Right to Know Laws:

Sodium Nitrite 7632-00.0 Sodium Tetraborate 1330-43-4 Water 7732-18-5 tNTERNATIONUr*CFEMUCA-CONTROL-WS.

CANADIAN ENVIRONMENTAL PROTECTION ACT (CEPA):

The substances In this preparation are listed on the Domestic Substances List (DSL), are exempt, or have been repoited in accordance with the New Substances Notification Regulations.

AUSTRALIA All substances in this product comply with the National Industrial Chemicals Notification & Assessment Scheme (NICNAS).

CHINA All substances In this product comply with the Provisions on the Environmental Administration of New Chemical Substances and are listed onthe Inventory of Existing Chemical Substances China (IECSC).

EU ROPE _________

The substances in this preparation have been reviewed for compliance with the EINECS or ELINCS Inventories.

JAPAN All substances in this product comply with the Law Regulating the Manufacture and Importation Of Chemical Substances and are listed on the Existing and New Chemical Substances list (ENCS).

KOREA All substances in this product comply with the Toxic Chemical Control Law (TCCL) and are listed on the Existing Chemicals Ust (ECL)

PHILIPPINES All substances In this product comply with the Republic Act 8969 (RA 6969) and are listed on the Philippines Inventory of Chemicals & Chemical Substances (PICCS).

16. 1OTHER INFORMATION This product material safety data sheet provides health and safety information. The product Is to be used in applications consistent with our product literature. Individuals handling this product should be Informed of the recommended safety precautions and should have access to this information. For any other uses, exposures should Nalco Company 1601 W. Diehl Road - Napervil!e, Illinois 60563-1198 - (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access.

9/10

Attachment NOC-AE-14003142 Page 152 of 155 Attachment J Requested Permit Amendments Admin Report 1.0, Pg. 1; Tech Report 1.0 - 12., Pg. 11

Attachment NOC-AE-14003142 Page 153 of 155 Attachment J - Amendment Requests Request to remove pH monitoring requirementsfrom Internal Outfolls 101, 201, and 501. STP Nuclear respectfully requests the removal of pH limitations and monitoring requirements from its internal monitoring locations. STP feels the requirement to monitor for pH at internal monitoring locations prior to wastewater entering its own cooling reservoir is overly burdensome and has little to no positive environmental impact. In fact, due to efforts by the plant to ensure the pH limits are met, STP must chemically treat these individual wastestreams prior to sampling at the internal monitoring locations. pH treatment would not be necessary to meet the effluent limits at the external Outfall 001 due to natural pH balancing that occurs in the cooling reservoir.

Request to remove effluent limits and monitoring requirementsfor relief well discharges at Outfalls 002, 003, 004, 005, and 006 and all associatedpermitrequirements having to do with relief well monitoring. STP requests the removal of the monitoring requirements for relief well discharges, placed in the previous TPDES permit draft. The water being discharged is predominantly groundwater that is seeping up to the surface from under the reservoir. The water is not pumped to the surface for discharge. STP has been conducting routine monitoring of its relief well discharges in compliance with its TPDES

  • permit since the permit was issued on April 5, 2012. STP has collected over two years' worth of data in that time. None of the data collected from the relief well monitoring program has exceeded an established effluent limit in the TPDES permit.

Attachment NOC-AE-14003142 Page 154 of 155 Attachment K Treatment System Tech Report, Item 2. a., Pg. 3

Attachment NOC-AE-14003142 Page 155 of 155 Wastewater Treatment System Treatment System Outfall Unit Dimensions Treatment Processes Main Cooling Reservoir 001 7,000 acre pond (irregular) Heat Dissipation

' Reuse/Rlecvcle Low Volume Waste 2-Neutralization Basins Neutralization' Metal Cleaning Wastes** 101 (300,000 gallons each) Mixing*

Neutralization Basin 68' x 42'x 16' Sedimentation Gross Oil Separator (API) Equalization Flotation 13,000 gallons Skimming*

24.".x 8'x 7'Skmig Low Volume Waste 201 Sedimentation Oily Waste Treatment System Tricellorator (DAF) 3,800 gallons Dissolved air flotation S9'die x 8' CoaquIaton*

Effluent Tank 850 gallons Multi-media Filtration 5' dia x 6' 2-Aeration Basins Screening 63" x 12" x 11 '6' Activated Sludge 2 Clarifiers 16' dia x 11 '6" Sedimentation West Sanitary Waste Treatment Primary Chlorine Contact 401 Chamber Disinfecton..

System*~ 6" x 12' x 1 '6" Secondary Chlorine Contact Chamber Disinfection~'*

I 4'dia x 4'3" Organic Basin Equalization Approx. 1,000,000 gallons Mixing*

100'x 80'x 17'6" Aeration*

Metal Cleaning Waste- 501 Inorganic Basin Coagulation' Approx. 50,000 gallons Chemical Precipitation*

25' x 25' x 13'3" Sedimentation Treatment Tanks (possible future Not-determined at this use) time.

2-Aeration Basins Screening 54'6" x 12:' x 3'3" Activated Sludge Training Sanitary Waste Treatment 601 1-Clarifier System** 6 2,0'. da x 133" Sedimentation Chlorine Contact Chamber Disinfection"-"

Note: Chlorine may be used intermittently to control algae growth in treatment units.

Treatment process may be used based on influent characteristics.

Outfall 501 is routed to Outfall 101. There have been no discharges from Outfall 501 since December 1992.

The West Plant is currently rated at 110,000 gallons per day (gpd) and the Training Plant at 66,000 gpd.

Sanitary wastewater will increase beginning with the construction of two new electric generating units (3 and 4) and an increase in construction personnel. The physical locations of the treatment systems and Outfalls 401 and 601 may change; however, the outfall descriptions in the permit would remain the same (i.e., monitoring at the discharge from the sewage treatment plant).

Disinfection may include sodium hypochlorite or calcium hypochlorite.

Technical Report 1.0 Page 3a