ML17252A829: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
 
(6 intermediate revisions by the same user not shown)
Line 2: Line 2:
| number = ML17252A829
| number = ML17252A829
| issue date = 02/18/1975
| issue date = 02/18/1975
| title = Dresden and Quad-Cities - High Energy Line Break Analysis
| title = Quad-Cities - High Energy Line Break Analysis
| author name = Abel J S
| author name = Abel J
| author affiliation = Commonwealth Edison Co
| author affiliation = Commonwealth Edison Co
| addressee name = Goller K R
| addressee name = Goller K
| addressee affiliation = NRC/NRR
| addressee affiliation = NRC/NRR
| docket = 05000237, 05000249, 05000254, 05000265
| docket = 05000237, 05000249, 05000254, 05000265
Line 15: Line 15:


=Text=
=Text=
{{#Wiki_filter:-----Commonwealfadison
{{#Wiki_filter:Commonwealfadison
* One First Nalional .a. Chicago. Illinois Address Reply to: Post Office Box 767 Chicago, Illinois 60690 Mr. Karl R. Goller Assistant .Director for Operating Reactors Directorate of Licensing .,February_ 18, 1975 Nuclear Regulatory Corranissioh Washington, D.C. 20555  
* One First Nalional . a . Chicago. Illinois Address Reply to: Post Office Box 767 Chicago, Illinois 60690
                                                      .,February_ 18, 1975 Mr. Karl R. Goller Assistant .Director for Operating Reactors Directorate of Licensing U.S'~ Nuclear Regulatory Corranissioh Washington, D.C. 20555


==Subject:==
==Subject:==
Dresden Sta1;.io.n Units 2 and 3, . Quad-Cities Station.Units 1 and 2, High Energy Line Break Analysis, NRC Dkts. 50-2-37, 50-254 and  
Dresden Sta1;.io.n Units 2 and 3, .
Quad-Cities Station.Units 1 and 2, High Energy Line Break Analysis, NRC Dkts. 50-2-37, 50-~49, 50-254 and 50~265


==References:==
==References:==
Dresden Station Specia1 Report No. 37 and Quad-Cities .Station Special Report No. 12  
Dresden Station Specia1 Report No. 37 and Quad-Cities .Station Special Report No. 12


==Dear Mr. Goller:==
==Dear Mr. Goller:==
The revised analysis of the consequences-of postulated high energy line breaks has been comp!eted and are being mitted by this cover letter. . . These revised reports the previously .submitted reports in their entirety. -The changes to the previous reports are indicated by solid vertical lines. The plant modification schedules, as submitted in our November 29, 1974.-letter, should be modified as follows: Dresden Unit 1 Dresden Unit 2 Dresden Unit 3 Quad-cities Unit Quad-cities c:v DDCKtrED USAEc P-ta22197 Unit 1 2 F:all . .197.5 Refueling Outage Spring 1976 Refueling Outage .Fall 1976 Refueling Outage *Spring.1976 Refueling Outage Spring 1976 Refueling Outage Very yours, !71wzL J *. S. Abel Nuclear Licensing Administrator Boiling Water Reactors . ::'**.* .. ' '' *.*'. '2028 * . \ . 
 
}}
The revised analysis of the consequences-of postulated                                         \ .
high energy line breaks has been comp!eted and are being trans~
mitted by . this cover letter.         .
These revised reports r~place the previously .submitted reports in their entirety. -The changes to the previous reports are indicated by solid vertical lines.
The plant modification schedules, as submitted in our
----- November 29, 1974.-letter, should be modified as follows:
Dresden Unit 1                                   F:all ..197.5 Refueling Outage Dresden Unit 2                                    Spring 1976 Refueling Outage Dresden Unit 3                                  .Fall 1976 Refueling Outage Quad-cities Unit 1                              *Spring.1976 Refueling Outage Quad-cities Unit 2                                Spring 1976 Refueling Outage c:v Very   tru~y    yours, DDCKtrED USAEc P-ta22197
                                                          !71wzL ~;,1, J *. S. Abel Nuclear Licensing Administrator Boiling Water Reactors
                                                                                          ' '' *.*'. '2028 *.}}

Latest revision as of 12:05, 4 February 2020

Quad-Cities - High Energy Line Break Analysis
ML17252A829
Person / Time
Site: Dresden, Quad Cities  Constellation icon.png
Issue date: 02/18/1975
From: Abel J
Commonwealth Edison Co
To: Goller K
Office of Nuclear Reactor Regulation
References
Download: ML17252A829 (1)


Text

Commonwealfadison

  • One First Nalional . a . Chicago. Illinois Address Reply to: Post Office Box 767 Chicago, Illinois 60690

.,February_ 18, 1975 Mr. Karl R. Goller Assistant .Director for Operating Reactors Directorate of Licensing U.S'~ Nuclear Regulatory Corranissioh Washington, D.C. 20555

Subject:

Dresden Sta1;.io.n Units 2 and 3, .

Quad-Cities Station.Units 1 and 2, High Energy Line Break Analysis, NRC Dkts. 50-2-37, 50-~49, 50-254 and 50~265

References:

Dresden Station Specia1 Report No. 37 and Quad-Cities .Station Special Report No. 12

Dear Mr. Goller:

The revised analysis of the consequences-of postulated \ .

high energy line breaks has been comp!eted and are being trans~

mitted by . this cover letter. .

These revised reports r~place the previously .submitted reports in their entirety. -The changes to the previous reports are indicated by solid vertical lines.

The plant modification schedules, as submitted in our


November 29, 1974.-letter, should be modified as follows:

Dresden Unit 1 F:all ..197.5 Refueling Outage Dresden Unit 2 Spring 1976 Refueling Outage Dresden Unit 3 .Fall 1976 Refueling Outage Quad-cities Unit 1 *Spring.1976 Refueling Outage Quad-cities Unit 2 Spring 1976 Refueling Outage c:v Very tru~y yours, DDCKtrED USAEc P-ta22197

!71wzL ~;,1, J *. S. Abel Nuclear Licensing Administrator Boiling Water Reactors

' *.*'. '2028 *.