{{#Wiki_filter:COLR 92-8 Rev.0 Controlled Copy No.9207 0l WNP-2 Cycle 8 Core Operating Limits Report June 1992 Washington Public Power Supply System 9207150308 92070b DOGY 05000397 PDR A PDg P-I 1 r WNP-2 Cycle 8 Core Operating Limits Report 920701 List of Effective Pages~Pa e 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35~Reviei 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0~0 0 0 0 0 0 0 0 0 0 0 0 0 I
{{#Wiki_filter:9207 0l COLR 92-8 Rev. 0 Controlled Copy No.
920701 WNP-2 Cycle 8 Core Operating Limits Report Table of Contents~Pa~e 1.0 Introduction and Summary..................................
WNP-2 Cycle 8 Core Operating Limits Report June 1992 Washington Public Power Supply System 9207150308 92070b PDR  ADOGY 05000397 PDg P-
1 2.0 Average Planar Linear Heat Generation Rate (APLHGR)Limits for Use in Technical Specification 3.2.1.................................
2 e'3.0 Mnmnum Critical Power Ratio (MCPR)Limit for Use in Technical S 1J~g pecuicahon 3.2.3.......................................
8 4.0 Linear Heat Generation Rate (LHGR)Limit for Use in Technical S 1J~g\pecuicabon3.2.4
....................,.............,....
27 5..0 References
.......................................
~....33 W'ashington Nuclear-Unit 2 COLR 92-8 Rev.0 I
920701 1.0 Introduction and Suxnlnary This report provides the Average Planar Linear Heat Generation Rate (APLHGR)limits, the Mnimum Critical Power Ratio (MCPR)limits, and the Linear Heat Generation Rate (LHGR)limits for WNP-2, Cycle 8 as required by Technical Specification 6.9.3.1.As required by Technical Specifications 6.9.3.2 and 6.9.3.3, these limits were determined using NRC-approved methodology and are established so that all applicable limits of the plant safety analysis are met.The thermal limits for SNP fuel given in this report are documented in the Cycle 8 Plant Transient Analysis Report (Reference 5.1), the Cycle 8 Reload Analysis Report (Reference 5.2), and the Power Dependent MCPR Limits for WÃP-2 Cycle 8 letter report (Reference 5.9).The thermal limits determined through the approved methodology are modified for the GE11 and SVEA-96 LFA's as discussed below.The WNP-2 Cycle 8 reload will include four Siemens Nuclear Power (SNP), four General Electric (GE), and four ABB Atom (ABB)Lead Fuel Assemblies (LFA's).The four SNP LFA's were inserted during the reload for Cycle 5.The four GE and ABB LFA's were inserted at the beginning of Cycle 6 and were designed to be compatible with the reload fuel utilized in Cycle 6.The Supply System will load the LFA's in core locations which, according to analysis, have sufficient margin such that the LFA's are not expected to be the limiting assemblies.
This approach is intended to exclude the LFA's ever being the limiting fuel assemblies on either a nodal or an assembly power basis.The GE11 LFA is described in the GEll Lead Fuel Assembly Report for washington Public Power Supply System Nuclear Project No.2, Reload 5, Cycle 6 (Reference 5.3).This reference describes the design goals of the GE11 LFA's and provides support for monitoring the GE11 LFA's at thermal limits based on the SNP 8x8 reload fuel thermal limits.The SVEA-96 LFA is described in the Supplemental LFA Licensing Report-SVZA-96LFA
's for TVÃP-2 (Reference 5.4).The process for developing thermal limits for the SVEA-96 LFA fuel based upon the SNP 8x8 reload fuel thermal limits is described in this reference and Reference 5.5.The MAPLHGR limits for the GE11 LFA's are the same as the SNP 8x8 reload fuel, except that a ratio ([64-2]/[81-7])
is applied to account for the different number of fuel pins in the two designs.The MAPLHGR limits for the SVEA-96 LFA's are the same as the SNP 8x8 reload fuel, except that a ratio ([64-2]/[100-4])
is applied to account for the different number of fuel pins in the two designs.Furthermore, the MAPLHGR limits for the SVEA-96 LFA's are multiplied 1)by 1.04 to account for a different estimation of the local power in the output from POWERPLEK compared to ABB'Atom methods and 2)by 1.02 to account for a different estimation of exposure in the output from POVFEM'LEX compared ABB Atom methods.This produces a combined multiplier of 1.06.A power dependent MCPR is specified in this report to define operating limits at other than rated power conditions.
For the WNP-2 core, feedwater-controller-failure transients from reduced power are calculated to be more severe than from full power conditions.
A flow dependent MCPR is specified in this report to define operating limits at other than rated flow conditions.
The reduced flow MCPR operating limit provides bounding protection for the limiting recirculation flow increase transient.
At less than rated conditions, the MCPR limit is the maximum of the rated power MCPR limit, the reduced power MCPR limit, and the reduced Washington Nuclear-Unit 2 COLR 92-8 Rev.0 920701 flow MCPR limit.This stipulation assures that the safety limit MCPR will not be violated throughout the WNP-2 operating regime.The LHGR limits for the GEl1 LFA's are the same as the SNP 8x8 reload fuel, except that a ratio ([64-2]/[81-7])
is applied to account for the different number of fuel pins in the two designs.The LHGR limits for the SVEA-96 LFA's are taken directly from Reference 5.4.Preparation, review and approval of this report were performed in accordance with applicable Supply System procedures.
The specific topical report revisions and supplements which describe the methodology utilized in this cycle specific analysis are referenced in Section 5.0 2.0 Average Planar Linear Heat Generation Rate (APLHGR)Limits for Use in Technical Specification 3.2.1 The APLHGR's for use in Technical Specification


====3.2.1 shall====
I 1
not exceed the limits shown in Figures 1, 2, 4, and 5 when in two-loop operation.and in Figures 1, 3, 4, and 5 when in single loop operation.
r
The limits for each fuel type as a function of Average Planar Exposure are provided for the Siemens Nuclear Power fuel, including the SNP LFA's, the SVEA-96 LFA fuel, and the GE11 LFA fuel.Washington Nuclear-Unit 2 COLR 92-8 Rev.0 HRIIIR~I=L+aHHHIHHHRh5-:~=IIIIIIIEIIIIIIII
, I'IIIIP=lie--IIIIIII=11155al
"''i55151:ill:sillls5lilliliIN
', I-.i=li'>IIP=-lillllIIIIINN5=---!IIIIIIIIIII 11:sllil-=5111 IillllllPI111515h~~e~gllailll5115
, 1=.,-511 5111111555115sllll','=ll-=h~liillli III , 111111 Isilills=*llialh'Hillillsl IIIIIII I!1155~151llalR'Hlllllal
.IIIIIR: 51551115111Ãllllhlllllll
., IIIIIII lilllll Illsiliilllh55515
, IIIIII), 1155 115111111511115 alii ,, IIIIIII IIII Illlllllllllili 155I 515lllilhmumnn Illlllllllllllllllll Illf 5 I Bl CC l1i I.a ala Iia~aaL'W ll a l%%Kg Q A gR g I:ILa II I I B I hh.a I a ma a aam am a'%$1 all 111 laa hi.am Ia a 2~III a==:IIPallllHI Ima~~~~~~~~~~~~~~A/A i>a I~I gM Ia weal Iwq Q R R R I 5 Ima aal III 055 M a alia ah%I.R im<I t~~~~~~~~~~~III~~II 8 IB=RRg'I h%1181811111 Bh<RI 11~e=L=8 a a 1 IR~1=1 1 a 18~aBa a 88~'1 a=I kaa 1 I e-=i g-III II RI"I.1 1 Ram IR I~I'~i I~I~I~~~~~~I~~I BRBBeBRRRBRRRRR I IIRR=g gg 1 BRAN R~~I~II IB I I IR lailm IL 1 RR':.'1 wC....: CC 5'I o~e I~~~
.I-=IS: SSSIIISS=11 SIISISSSSSII
., IIIIIISII ISIIIIIISSI5llMISSSISSS
, NSIIL~S SSIISIIIISSSSSIlhlSSIISI
, Illlilllllllli 11;-PAIII 15555555a55555 II...'..Illhil , IISISI 555511:~555~5'=ll I~".55555, IISSII<-iII<5 SlIP , 555551, 555555 Sl I IIIIII IIISI 55555555555>55515515
, Ill.i.......11115 55.55~55555555
,'lllllllllllllllllll llllllllllllll
~~~
=:=-=555=111111 , O'.1 SR==i-551~51151i55--RRSR illllll ,'ii 11: illl-11111111-a5555iRRi555
~s~~s-., 1=',ll-----.--R=,-arne=-aa-5554%~.:, SSsRSI'l ll:-111-=:illllll R SERAI Sil'.ll.='=RRRPi555555 111111'" 1 li551='RRii'555555 1 I-Rhh>mnmm 1=-=55-==-55>Ra555555
.,11 555=11111111illl 111 11111111 920701 3.0 MinimUm Critical Power Ratio (MCPR)Limit for Use in Technical Specification 3.2.3 The MCPR limit for use in Technical Specification


====3.2.3 shall====
920701 WNP-2 Cycle 8 Core Operating Limits Report List of Effective    Pages
be: a)Greater than or equal to the greater of the limits determined from Tables la and 1b and Figures 6 and 7a through 14b.b)The full power limit is determined at 104%power and 106%core flow.Washington Nuclear-Unit 2 COLR 92-8 Rev.0 Table la WNP-2 Cycle 8 MCPR Operating Conditions Cycle Exposures (4244 MWd/MT Condition Limit Nss'" Full Power Flow Dependent SLMCPR~1,07+SNP 8xg SNP 9x9 SNP 9x9 SVEA-96 GF.11 LFA LFA 1.23+1.23+1,25 136+Figure 6 Tsss~n Power Dependent Fig.7a Fig.7a Fig.8a Fig, 7a Full Power Flow Depcndcnt 1.24 1.25 1.32 1.37 Figure 6 Nssu~Power Dependent Fig.9a Fig, 9a Fig.10a Fig.9a RFI'ull Power Inoperable Flow Dependent Power Dependent SLO NSS Full Power Flow Depcndcnt 1.26 1.28 1.37 1.40 Figure 6 Fig.13a Fig.13a Fig.14a Fig.13a 186 1.36 1:36 1,$5 None Power Dependent Fig.7a Fig.7a Fig.8a Fig.7a SLO~VSSS Full Power Flow Dependent 186 1.36 136 1.85 None Power Dependent Fig.9a Fig.9a Fig.10a Fig.9a SLOP NSS RFr Full Power Inoperable Flow Dependent 186 136 1.36 1.85 None Power Dependent Fig.13a Fig, 13a Fig.14a Fig, 13a'ashington Nuclear-Unit 2-9-COLR 92-8 Rev.0 92%01 Table lb WNP-2 Cycle 8 MCPR Operating Conditions Cycle Exposures>4244 MWd/MT SLMCPR~1.07m SLMCPR~1.07 FFfR Condition Limit Nssu)Full Power Flow Dependent Power Dependent TSSS<'>1.24 1.25 192 137 Figurc 6 1.26 1.27 1.34 1.40 Figure 6 Fig.7b Fig.7b Fig.8b Fig.7b Fig.11 Fig.11 Fig.12 Fig.11 SNP sx8 SNP 9x9 SNP 9x9 SVBA-96 SNP 8x8 SNP 9x9 SNP 9x9 SVBA-96 GB11 LFA" LFA GB11 LFA LFA NSSto Full Power Flow Dependent Power Dependent 1.28 1.29 138 1.43 Figure 6 Fig, 9b Fig.9b Fig.10b Fig.9b Not Analyzed RFI'ull Power inoperable Flow Dependent Power Dependent SLO(" NSS 1.31 1.33 1.46 1.48~Figurc 6 Fig.13b Fig.13b Fig.14b Fig.13b Not Analyzed Full Power Flow Dependent Power Dependent SLOmTSSS 186 1.36 1.36 None 1.85-1.56 1.36 136 1.85 Noae Fig.7b Fig.7b Fig.8b Fig.7b Fig.11 Fig.11 Fig.12 Fig.11 Full Power Flow Dependent Power Depcadcat SLOP NSS RPT Full Power Inoperable Flow Dependent Power Dcpeadent 1.56 1.36 1.36 1.85 None Fig.9b Fig.9b Fig.10b Fig.9b 156 136 136 1.85 None Fig.13b Fig.13b Fig.14b Fig.13b Not Analyzed Not Analyzed W'ashington Nuclear-Unit 2-10-COLR 92-8 Rev.0 Notes for Table 1 Note 1: These MCPR values are based on the SNP Reload Safety Analysis performed using the control rod insertion times shown below (defined as normal scram speed: NSS).In the event that Surveillance 4.1.3.2 shows these scram insertion times have been exceeded, the plant thermal margin limits associated with NSS default to the values associated with the Technical Specification scram speed (TSSS).The scram insertion times must meet the requirements of Technical Specification 3.1.3.4.Position Inserted From Fully Withdrawn Notch 45 Notch 39 Notch 25 Notch 5 Slowest measured average control rod insertion times t specified notches for all operable control rods for each grou of four control rods arranged in a two-by-two array (seconds)0.380 0.690 1.500 2.750 Note 2: For Single Loop Operation, the SLMCPR increases by 0.01.Note 3: The control rod withdrawal error (CRWB)analysis was performed with the nominal rod block monitor (RBM)setting value of 1.06.Use of the nominal setpoint is in accordance with the methodology described in Reference 5.12, consistent with approved industry practice.CRWH is limiting for the noted full power limits for cycle exposures less than 4244 MWd/MT.The load rejection without bypass (LRNB)event is limiting for the remaining full power events.Washington Nuclear-Unit 2 COLR 92-8 Rev.0 f%g gg g%%%g g%m%wow~~:~aaaaaaaaaaaa I I h<I I i i EE hi<I~El I El 3 3333333333333
~Pa  e                              ~Reviei 1                                   0 1                                   0 2                                   0 3                                   0 4                                   0 5                                   0 6                                  0 7                                  0 8                                   0 9                                  0 10                                  0 11                                   0 12                                  0 13                                  0 14                                  0 15                                   0 16                                  0 17                                  0 18                                  0 19                                  0 20                                  0 21                                  0 22                                  0 ~
~a~~>>>>>>~'3''"Em~5 aC a a El RRwwwawaaaeaaa hhsEi<i Isa<I~'>>~~>>~I'>>I'>>~~'>>~g>>~~'>>~'>>\~~::>>
23                                  0 24                                  0 25                                  0 26                                  0 27                                  0 28                                  0 29                                  0 30                                  0 31                                  0 32                                  0 33                                  0 34                                  0 35                                  0
g%%w I WWW%g WWW~o~s..~F55~Ii%Kg 5RAR RP%AH~5~~~~~~~~~I cl 555 CCCWOQRR 5~'e~4~~'~~~g 0~~~~~~~~~~~:.o gaa aaa)P RII p I11%)$I 55 aaa aa a/a aaa g aaa~~~~~~~~QaC WRR aa gaa ala aaaa aaa aalu mh==-..l 5 I Ile I i'h)a W'~~~~~~~~~s s~I's almlKIHillHIRIIII IIIIIII imp~i~i I~I~)~a~I~~~I~s~~s~~gmII~~s~~.s g>>50 g~~~R*1m I I I=~ma-Siilmm s I Bml BIN II)I I~5 CCC RaC g,-l hh~'s~'~~'s~'~~~~~'~~s I I'~s:.s 5%58 55 855 aihh~il.IE I li IEI lij~P, I I 11 I 15 hh,.ailli 515lallgiifP<I I a h~I I..5955555551.555a55 I I WOO%SR'O SOS Iiii IIEEIEIEIIEIII 11 a a I 0%%S aalu 8 580 8%Iiai I al I%SR OS%0 0%OR 8RO 8 8 W 8~Q 0 0 I wQgx w a ha<aE.i.a a I I a:a EaE RR7 rrr rrr Ea a rrr rrr r r rarh rrr rr E E QES>Ra aaa aa 55hlk mm$&/&Mmmm~~~~I~~~I II'I Nallaaalliiillaiii ILS I e r r rrr aaa rrr$/a a A r rrrr rr r s a%as sa La I~~I~I rr err 88~8~I~~~.I r r rrrr rrr rr r r err rr rr r r 5 r rrr rr r r e r rrrr rr r r r r rrr rrr rrrrrr rrr ila iai ilia.,aE aaa aaaaaaaa I<.a Iliaiii a EE''i~I'~~I~I~.I~I I 0.~;'.~~~I~~'~~~~'
'IP~R ag Ilg~.M 55 pl 5 Sg R~~I I~I std I~.~m RWRWWWWWWW%
.hx-..~5 5 5 55 W I I~'.hgssss S RR R Q QQRRRRe A~~~~~~~~S 8 W SOS~Rl II~I RRR~~'e~'o~~o~'o~~'~~~~~~~~~~~~~~~~I I S%SSO~aaam gaa~aa aalu raa Raa E mRil gaa gga ISAAC RWO Pea maa~aa aalu 55~aa SWO ar WS Imiha 888 SQQ QSR%SR I I IIa I Lmma hpg ga g aa SOS ear SOS E$1.~kg Ile SQS Ii RI aaa ala RS%S W WW Naa gWSR RSRS~~~~s.QQR II:..ia.Iiii QRR RRRHR RES khlhaa.h Ia p C-a%gg ha~~~~~~aa aaa SR SOS'm~I I a aaa aaa5 aaaawawwaaaa
~I'o~~~~I~g I~I'i RQ I'e cac I ccc E c.Il ha;SS 58 5 58 SO'y~~~cc~c cc c cR c c I II~R Q c~Icl Ii ca c HER gSSR m W~s~~~:.s 8 m RwlR&#xc3;wwwwwQHQit cc Ra~c c ERR Sc&#xc3;S SgBQ)Rc clw c a w~la.I.I II 8 0 SS~~'e~~~~~~~~'i ICC c52 EE EEEE SERI CC2E 2LI Cila.ii aiba CESS ICE 2CRR iil EEE E EC2 Cai RRRRL.22I ECE EEE EL" QE QE ERE SM Sa EEE EER E EE r E E~~~~~~I~I I~o CIEE EI E EE 2 iaa 222 hh~J ia aa'.I 2 EEE EEEE EEEE EEEE~I~~~.laiasseEEESEE EE EEE EE EEE EE EEE E E EE ci LJ5 I SE2 E E EE E EEE EEEE EEE EEE EES SEE E EEE E E E EE EE Iai I22 al RE%I CI ha, I caa 2 2 2~I~'o g5 RCg g g 55$89 E=R a 58$8$CRR 5 ma maaa Cml~~5555~~55~1555555 W 5: 'o~I a 0 0 g I hh g g 55/g A 5%WR==5~5 gRI$8%&%%W Hg&W ml R%WA WW~Rg gg55/gg)/QC/l~~~~g M%%%~~~~~.~J~5 W 5g ae5 5g)gag a~~CmCm Wgg%%[HE g<jg gg e RR1 5 RRha~'s~~
il.~ah ERa aalu OAR aaI La QQR wl aa aas al ad%~a Ila ORS 8 WQ SWOR%aalu SOS S88 5555 OWNS 888 WS 8 WQQ SS SS ia.I I p I aa: aaa OS 0 0~-I RS Sh'0 8 RQ 0 SOS RER aaa la gl lia all 0 0 SR SQS WS IPI ap I~I aL a 555 QS I:I aal 2+l E aa L~'e~o~~'a~e~~~~~~I~'s~i.s~I~~~~~~
k k k II k kk kk k k F I I.I III I 8 IIa III II I~iIIIiIL'I Illlih INN Q kkk IIla~'II Im ESESRRSSRRSR Ii I~I I WRSggR a RS WWLRLC 5~g)l 5 aa I.hh;.,I mhhp%$/p mr~I I Il~'~I'o~~~~I~'o I~~~~
~55 I~EW I$15 I g IR ha Igg p$pgg g g RRI aaSQ 8 R SSR gag Ilg al8 aaa SgO S 8 ES8 51 m~l5 RWKWKHWHR g o~~~~o g gggg 0 Q%8 8~aiba a R SO S SOS S S SOS 8 gSE LR Ep gE SE IWg al HhHa 8 gIC gS SS rr Ill gal%apl gR I y 4 t g~~~~f~~~~
k kk g'%g kkk kkk II IL ARR III kkk kkkk la kk kkk~kk~kk~k k Qaa Ila a~al kh>kW k 5 k I aa I~'i OS~I k II~I laa laal 55M~~kkk kk k 5 aaaI IL lla aa IaaaII laI'Iaa ll lllahmla Iaal L I I haa<III I I I~~~I I k k k ak ilk SQS Slays/SSS SSS~ak ASS SSS SSS XSS ASS SSAII~ka SSS~ka SSS SSS lll SSS akk SSS SSS SSS S~SS S S kaa Illa a~kk kkk~~kk Lkgk kkk SSS SSh Q g S~ll lla F.SS SSS SOS I~~~I RES~5IINIIHI SSS SS SS SWISS SSS SSS I'o c a SS SS ak S ak~ak Iak~kl SSS~ak SSS SSS a l'l'a Ilk kl~kk a SS SSS~a~S SS SSa q S kkkgk kk~ak SSS S S R S S S~I~a:i ala ASS Si~kl I SSS SSS SS SS~SS SS i(k kkk ha'a SSS ASS SSSS'a ll S ii SS SSSS SSS 920701 4.0 Linear Heat Generation Rate (LHGR)Limit for Use in Technical Specification 3.2.4 The LHGR limit for use in Technical'Specification


====3.2.4 shall====
I 920701 WNP-2 Cycle 8 Core Operating Limits Report Table of Contents
not exceed the values shown in Figures 15, 16, 17, 18, and 19.Washington Nuclear-Unit 2-27-COLR 92-8 Rev.0 DIES ESgSSEgE Smg EpE 0 8 SS I Iil ill Ill Ill I a ae E~1 5555555a555
                                                                                ~Pa ~e 1.0    Introduction and Summary    ..................................                  1 2.0    Average Planar Linear Heat Generation Rate (APLHGR) Limits for Use in Technical Specification 3.2.1.................................                  2 e
''I I Ig ,>Ill Psa sa5 NS BL il liei~lll ii L~IEgs gism%)san gs E REL 851i LR I~)'.ii Ii.B5:.i.p Ill CII RI~1<ggl1..I iii lul hii hau I~I~I~I I~~I I~II~II I~I~'I~~~III II~~I~~~
'3.0    Mnmnum Critical Power Ratio (MCPR) Limit for Use in Technical
I I I'I II I I I Ii~gII gII I SmkSISS5 NSNNARSm Rmh'cl RNm~~EH$PPI sk I!maim--'-'-'--ll ,i.I~Ill WNAA SSaaraaaaaaaaarar NAS RNNRiASS ming>iARi Wi NARON IIIII ailllll Ill I~.I:.I: i:IIIIII III~I N SNmmmw Nmmsmmms Nlm 50k'A iiQRAm 5 8 II IIII I!'!ill Ia I 1,.~I m m I SE~IQIRMR REIRmgI IRRER I"'-lil i"i"~IIIII I~IIllhh50iRRIRIIII aLslaa IIILIIIR LIhhlls$IIIL Is IRRIRERI PREWRPlgRII
            ~ g S pecuicahon 1J      3.2.3  .......................................                    8 4.0    Linear Heat Generation Rate  (LHGR) Limit for Use in Technical pecuicabon3.2.4 ....................,.............,....
~IIIIIIII IIILIII R4L.SR IIII!illi I!i'.Ill!!I!11 ii g aaaRaEQEggaaap)EEE SOS SQS ASS>Iso'SSA N%RID 5 NSWiSN S AS%SEAR~ggaagp rnsuL SIQSNNOO RANNSRNS ESSSSOSS AkS S RN aa 0 QRO awmmrraa~~ISSSSASS I~I , aiiiiilalialiallli
g\                                                                      27
~alaiaiii liia ill 5 aa OSWSR 55 NSSSN 55 RS555 55 QiiSSRSSSiSSSSNSiRSRR iiSSSR~SRSSIk%5 IQSkSSSE11%1191%
            ~
lli.laaii aalalia.liil.ah..I iii illl I ialliii a aa2aaiahgg ass Ia IElilli lal Iia I en~~~~~~~~~~~~~~Ii~II~~~I~
S    1J 5..0  References  ....................................... .. ..            ~        33 W'ashington Nuclear-Unit 2                                            COLR 92-8 Rev. 0
kk k A kkkkkk%%%%%%&$5%Akk MAX k kkkk''k AWAA.I;A k kkkr"'Akkkkk kkkkkk s I~~I I I I A Akkkkkk ARAA kk I~~I A Akk IIIimamilmmaaaIIIam.aalm aa aeaemm IISIIII aCRamaas kkkkkkkk kkkkkkkk Akkkkk Akkk A amIRLa RIRIaa kkkkkkkkkk kkkkkk kkkkkkkk kkkkkkkk WAMkkkkk Akk kkkk Akkkkkk rkr MWW k kk k Wk WWAAAAAXM kkkkkk W kkkkkkkkk Akkkkk k kkkkkkkkk Akkkk kkk a sar Ia al r aaa kkkSkkkkkkkkkk)kg kk k kgkkkkkk g kk , haaKaiba aaL11 1 Rs1 11as sLassa1 1 1 s s1sagagpgggassm saass1I sggsgsg I am~a~1 1 asRaRaa IgssgSChsh g a 1 1 1 1 sassssmLs Las1s s1~sgsaa1s~s s is~)gas s1sa as a~~I1 1 II E I I I~II.e: k k kkk kkk k k k$i k kk kkkk I1 iiiii'-'-.-".,~hh h5imi 1 l1i 1.~sass sassafras a1al1 as kkkkkkkk kkkkk kkkkkkl~k ONkkkkN k OOOEkkkk ROSE kkkkkkkl MOOOOEE O O kkk kk ua1 1raaas1.Iialggi LNLS: NsCa asCs1L haslLuah~sasasa ggilgip I 1 a1aa sassa]ss~pa)lass~L1111 11 ssLSRR aasRaaL sssLCs18 shah'.I kk k kkk kk k kk kk k kkk kkkkk~iii~~~~~iii~i~ii~~~
 
92070l 5.0 References 5.1 EMF-92-039, Revision 1, WNP-2 Cycle 8 Plant Transient Analysis, Siemens Nuclear Power Corporation, June 1992.5.2 EMF-92-040, Revision 1, WNP-2 Cycle 8 Reload Analysis, Siemens Nuclear Power Corporation, June 1992.5.3 GE11 Lead Fuel Assembly Report for Washington Public Power Supply System Nuclear Project No.2, Reload 5, Cycle 6, General Electric Company, December 1989 (Proprietary).
I 920701 1.0    Introduction and Suxnlnary This report provides the Average Planar Linear Heat Generation Rate (APLHGR) limits, the Mnimum Critical Power Ratio (MCPR) limits, and the Linear Heat Generation Rate (LHGR) limits for WNP-2, Cycle 8 as required by Technical Specification 6.9.3.1. As required by Technical Specifications 6.9.3.2 and 6.9.3.3, these limits were determined using NRC-approved methodology and are established so that all applicable limits of the plant safety analysis are met. The thermal limits for SNP fuel given in this report are documented in the Cycle 8 Plant Transient Analysis Report (Reference 5.1), the Cycle 8 Reload Analysis Report (Reference 5.2), and the Power Dependent MCPR Limits for W&#xc3;P-2 Cycle 8 letter report (Reference 5.9). The thermal limits determined through the approved methodology are modified for the GE11 and SVEA-96 LFA's as discussed below.
5.4 UK 90-126, Supplemental Lead Fuel Assembly Licensing Report-SVE'A-96LFA's for WNP-2, ABB Atom, January 1990 (Proprietary).
The WNP-2 Cycle 8 reload will include four Siemens Nuclear Power (SNP), four General Electric (GE), and four ABB Atom (ABB) Lead Fuel Assemblies (LFA's). The four SNP LFA's were inserted during the reload for Cycle 5. The four GE and ABB LFA's were inserted at the beginning of Cycle 6 and were designed to be compatible with the reload fuel utilized in Cycle 6. The Supply System willload the LFA's in core locations which, according to analysis, have sufficient margin such that the LFA's are not expected to be the limiting assemblies. This approach is intended to exclude the LFA's ever being the limiting fuel assemblies on either a nodal or an assembly power basis. The GE11 LFA is described in the GEll Lead Fuel Assembly Report for washington Public Power Supply System Nuclear Project No. 2, Reload 5, Cycle 6 (Reference 5.3). This reference describes the design goals of the GE11 LFA's and provides support for monitoring the GE11 LFA's at thermal limits based on the SNP 8x8 reload fuel thermal limits. The SVEA-96 LFA is described in the Supplemental LFA Licensing Report SVZA-96LFA's for TV&#xc3;P-2 (Reference 5.4). The process for developing thermal limits for the SVEA-96 LFA fuel based upon the SNP 8x8 reload fuel thermal limits is described in this reference and Reference 5.5.
5.5 ATOP-91-120, W.R.Harris, ABB, to D.L.Whitcomb, Supply System, Assembly Treatment in WNP-2 Cycle 7 Core Operating Limits Report, May 1, 1991.5.6 SNPWP-92-0059, Udell Fresk, Siemens Nuclear Power Corporation, to R.A.Vopalensky, Supply System, Comments on WNP-2 Cycle 8 Draft COLR Report, May 21, 1992.5.7 5.8 JTW:92-087, J.T.Worthington, General Electric Company, to D.L.Whitcomb, Supply System, WNP-2 Cycle 8 Core Operating Limits Report, Contract No.C-21099, Gall Lead Fuel Assemblies, May 22, 1992.ATOP-92-062, W.R.Harris, ABB Atom, to D.L.Whitcomb, Supply System, SVE'A-96 Lead Fuel Assembly Treatment in'WNP-2 Cycle 8 Core Operating Limits Report, May 15, 1992.5.9 SNPWP-92-0072, Udell Fresk, Siemens Nuclear Power Corporation, to R.A.Vopalensky, Power Dependent MCPR Limits for WNP-2 Cycle 8, June 24, 1992.5.10 ANF-89-014(P)(A), Revision 1 and Supplement 1&2, Generic Mechanical Design for Advanced Nuclear Fuels 9'-1X and 9x9-9X Reload Fuel, Advanced Nuclear Fuels Corporation, Richland, WA, October 1991.5.11 XN-NF-79-71(P), Revision 2, including Supplements 1,2 and 3(A), Enon Nuclear Plant Transient Methodology for Boiling Water Reactors, Exxon Nuclear Company, Inc., Richland, WA, November 1981.5.12 XN-NF-80-19(P)(A), Volume 1 Supplement 1 and 2, Exron Nuclear Methodology for Boiling Water Reactors Neutronic Methods for Design Analysis, March 1983.Washington Nuclear-Unit 2-33-COLR 92-8 Rev.0 5.13 i 92%01 XN-NF-80-19(P)(A), Volume 1 Supplements 3 and 4, Exxon Nuclear Methodology for Boiling Water Reactors Neutronic Methods for Design Analysis, Advanced Nuclear Fuels Corporation, Richland, WA, November 1990.5.14 XN-NF-80-19(P)(A), Volume 3, Revision 2, Exxon Nuclear Methodology for Boiling Water Reactors THERMEK Thermal Limits Methodology Summary Description, Exxon Nuclear Company, Inc., Richland, WA, January 1987.5.15 XN-NF-80-19(P)(A), Volume 4, Revision 1, Exxon Nuclear Methodology for Boiling Water Reactors: Application of the ENC Methodology to BWR Reloads, Exxon Nuclear Company, Inc., Richland, WA, June 1986.5.16 ANF-913(P)(A), Volume 1, Revision 1 and Volume 1, Supplements 2, 3, and 4, COTRANSA2:
The MAPLHGR limits for the GE11 LFA's are the same as the SNP 8x8 reload fuel, except that a ratio ([64-2]/[81-7]) is applied to account for the different number of fuel pins in the two designs. The MAPLHGR limits for the SVEA-96 LFA's are the same as the SNP 8x8 reload fuel, except that a ratio ([64-2]/[100-4]) is applied to account for the different number of fuel pins in the two designs. Furthermore, the MAPLHGR limits for the SVEA-96 LFA's are multiplied 1) by 1.04 to account for a different estimation of the local power in the output from POWERPLEK compared to ABB 'Atom methods and 2) by 1.02 to account for a different estimation of exposure in the output from POVFEM'LEX compared ABB Atom methods. This produces a combined multiplier of 1.06.
A Computer Program for Boiling Water Reactor Transient Analyses, Advanced Nuclear Fuels Corporation, Richland, WA, August 1990.5.17 ANF-524(P)(A), Revision 2 and Supplements 1 and 2, Advanced Nuclear Fuels Critical Power Methodology for Boiling Water Reactors, Advanced Nuclear Fuels Corporation, Richland, WA, November 1990.5.18 ANF-1125(P)(A) and Supplements 1 and 2, ANFB Crirical Power Correlation, Advanced Nuclear Fuels Corporation, Richland, WA, April 1990 5.19 5.20 5.21 Letter, R.C.Jones (NRC)to R.A.Copeland (ANF), NRC Approval of ANFB Additive Constants for 5%9-5K BWR Fuel, November 14, 1990.Letter ENWB-96-0067, J.B.Edgar (ANF)to Supply System, Supplemental Licensing Analysis Results, April 15, 1986.ANF-90-01, WNP-2 Cycle 6 Plant Transient Analysis, Advanced Nuclear Fuels Corporation, Richland, WA, January 1990.5.22 XN-NF-84-105(P)(A), Volume 1 and Supplements 1, 2,&4, XCOBRA-T: A Computer Code for BWR Transient Thermal Hydraulic Core Analysis, Exxon Nuclear Company, Inc., Richland, WA, February 1987.5.23 XN-NF-81-21(P)(A), Revision 1, Generic Mechanical Design for Exxon Nuclear Jet Pump BWR Relouf Fuel, Exxon Nuclear Company, Inc., Richland, WA, September 1982, and Supplement 1, March 1985.5.24 XN-NF-85-67(P)(A), Revision 1, Generic Mechanical Design for Exxon Nuclear Jet Pump BWR Reload Fuel, Exxon Nuclear Company, Inc., Richland, WA, September 1986.Washington Nuclear-Unit 2-34-COLR 92-8 Rev.0 5.25 TAC M83319, Docket 50-397, Proposed Bx8 Fuel Burnup Extension for Cycle 8-WNP-2 PAC No.M83319), R.R.Assa, NRC, to G.C.Sorensen, July 1, 1992.5.26 XN-NF-81-58(A), Revision 2, RODEX2: Fuel Rod Mechanical Response Evaluation Model, Exxon Nuclear Company, Inc., Richland, WA, March 1984.5.27 XN-NF-87-92 and Supplement 1, WNP-2 Plant Transient Analysis With Final Feedwater Temperature Reduction, Advanced Nuclear Fuels Corporation, Richland, WA, June 1987'and May 1988.5.28 ANF-87-119, WNP-2 Single Loop Operation Analysis, Advanced Nuclear Fuels Corporation, Richland, WA, September 1987.5.29 ANF-87-118, WNP-2 LOCA Analysis For Single Loop Operation, Advanced Nuclear Fuels Corporation, Richland, WA, September 1987.5.30 Letter, R.B.Samworth, USNRC, to G.C.Sorensen, Supply System, Issuance of Amendment No.62 to Facility Operating License No.NPF-21-WPPSS Nuclear Project 2 (TAC No.67538), August 5, 1988.5.31 XN-NF-85-138(P),LOCA Break Spectrum for a BWR 5, Exxon Nuclear Company, Inc., Richland, WA, December 1985.5.32 XN-NF-85-139, WNP-2 LOCA-ECCS Analysis, MAPLHGR Results, Exxon Nuclear Company, Inc., Richland, WA, December 1984.5.33 ANF-CC-33(P)(A), Supplement 2, HLXY: A Generalized Multirod Heatup Code with 10 CFR SOAppendix ZHeatup Option, Advanced Nuclear Fuels Corporation, Richland, WA, January 1991.5.34 XN-NF-81-22(P)(A), Generic Statistical Uncertainty Analysis Methodology, November 1983.5.35 NEDE-24011-P-A-6, General Elecmc Standard Application for Reactor Fuel, April 1983.Washington Nuclear-Unit 2-35-COLR 92-8 Rev.0}}
A power    dependent MCPR is specified in this report to define operating limits at other than rated power conditions. For the WNP-2 core, feedwater-controller-failure transients from reduced power are calculated to be more severe than from full power conditions. A flow dependent MCPR is specified in this report to define operating limits at other than rated flow conditions. The reduced flow MCPR operating limit provides bounding protection for the limiting recirculation flow increase transient. At less than rated conditions, the MCPR limit is the maximum of the rated power MCPR limit, the reduced power MCPR limit, and the reduced Washington Nuclear-Unit 2                                                     COLR 92-8 Rev. 0
 
920701 flow MCPR limit. This stipulation assures that the safety limit MCPR will not be violated throughout the WNP-2 operating regime.
The LHGR limits for the GEl1 LFA's are the same as the SNP 8x8 reload fuel, except that a ratio ([64-2]/[81-7]) is applied to account for the different number of fuel pins in the two designs. The LHGR limits for the SVEA-96 LFA's are taken directly from Reference 5.4.
Preparation, review and approval of this report were performed in accordance with applicable Supply System procedures. The specific topical report revisions and supplements which describe the methodology utilized in this cycle specific analysis are referenced in Section 5.0 2.0    Average Planar Linear Heat Generation Rate (APLHGR) Limits for Use in Technical Specification 3.2.1 The APLHGR's for use in Technical Specification 3.2.1 shall not exceed the limits shown in Figures 1, 2, 4, and 5 when in two-loop operation.and in Figures 1, 3, 4, and 5 when in single loop operation. The limits for each fuel type as a function of Average Planar Exposure are provided for the Siemens Nuclear Power fuel, including the SNP LFA's, the SVEA-96 LFA fuel, and the GE11 LFA fuel.
Washington Nuclear-Unit 2                                                   COLR 92-8 Rev. 0
 
HRIIIR~I=L+aHHHIHHHRh5-:~=IIIIIIIEIIIIIIII
  , I'IIIIP=lie--IIIIIII=11155al            "''
  'i55151:ill:sillls5lilliliIN I-.i=li'> IIP=-lillllIIIIINN5=---!IIIIIIIIIII 11:sllil-=5111 IillllllPI111515h~~e~gllailll5115
  , 1=.,-511  5111111555115sllll','=ll-=h~liillli III
,   111111                Isilills=*llialh'Hillillsl IIIIIII IIIIIR:                I!1155~151llalR'Hlllllal 51551115111&#xc3;llllhlllllll IIIIII),               lilllll
., IIIIIII                        Illsiliilllh55515 1155 115111111511115 alii IIII Illlllllllllili
,, IIIIIII                                      155I 515lllilhmumnn Illlllllllllllllllll          Illf
 
5    I    %%Kg Q A             gR              A/A Bl        I:ILa a I a II g
I        i>a I
I I hh.
B ma a      aam      am a      '%$1
                                                  ~  I gM        M a
all      111      laa          hi. wealIa CC l1i                                              Iwq ala                                      am      Q R I.a                                      Ia          R Iia                                              I5 R
~aaL'W                                  a 2             alia    ah%
Ima      I.R        im  <I ll                      ~  III aal III a
l    a==:IIPallllHI Ima
      ~ ~ ~    ~ ~ ~ ~    ~ ~ ~    ~ ~ ~ ~
055 t~~    ~ ~ ~ ~  ~ ~ ~  ~ ~ III ~
                                                                                  ~ II
 
IBRBBeBRRRBRRRRR                8    IB
                                    'I
                                          =    RRg I
IIRR BRAN R~~
II
        =g IB IR lailm IL 1 a I.'1 I~ 1 h% 1181811111 gg I~
1 Bh<
e=L IR~
RI
                                                =
                                                '1 18 ~aBa 1=1 8      11 a a 1
a RR wC 5
        ...    .: I
                  '          CC 88~
a=I e-=i kaa          1 I
g- III o  ~ e I I          II        RI "I.
I'      i        I~ I      I~
1 1      Ram      IR
    ~        ~                  ~    ~    ~ ~ ~    ~ I~ ~  ~ ~ ~
 
I-= IS:  SSSIIISS= 11      SIISISSSSSII
., IIIIIISIIISIIIIIISSI5llMISSSISSS NSIIL~S SSIISIIIISSSSSIlhlSSIISI
,   Illlilllllllli    11; 15555555a55555 II ...'..
PAIII Illhil IISISI            555511:~555~5'=ll  I~"
55555,            IISSII<-iII<5 SlIP 555551, 555555 Sl I IIIIII IIISI              55555555555>55515515 Ill.i  ....... 11115 55.55~55555555
  'lllllllllllllllllll llllllllllllll
                  ~ ~  ~
 
,'ii 11: illl-11111111- a5555iRRi555
  , O'.1 SR==i-551~51151i55--RRSR            illllll
                                    =:=-=555= 111111
                      'l s  ~ s-
                                  ~  ~
., 1=  ',ll              R=,-arne=-aa-      5554%
:, SSsRSI R SERAI 111111
            ~ .
                '"            ll:-111-=:illllll Sil'.ll.='=RRRPi555555 1 li551='RRii'555555 1 I-Rhh>mnmm 1 =-=55-==-55>Ra555555
.,11 555        =11111111illl 111 11111111
 
920701 3.0  MinimUm Critical Power Ratio (MCPR) Limit for Use in Technical Specification 3.2.3 The MCPR limit for use in Technical Specification 3.2.3 shall be:
a)   Greater than or equal to the greater of the limits determined from Tables la and 1b and Figures 6 and 7a through 14b.
b)    The full power limit is determined at 104% power and 106% core flow.
Washington Nuclear-Unit 2                                                  COLR 92-8 Rev. 0
 
Table    la WNP-2 Cycle 8 MCPR Operating Conditions Cycle Exposures      (  4244 MWd/MT SLMCPR    ~ 1,07+
SNP 8xg    SNP 9x9    SNP 9x9 SVEA-96 Condition Limit            GF.11 LFA              LFA Nss'"
Full Power      1.23+      1.23+      1,25    136+
Flow Dependent                    Figure 6 Power Dependent Fig. 7a    Fig. 7a    Fig. 8a  Fig, 7a Tsss~n Full Power      1.24        1.25      1.32    1.37 Flow Depcndcnt                    Figure 6 Power Dependent Fig. 9a    Fig, 9a    Fig. 10a Fig. 9a Nssu~
RFI'ull          Power      1.26        1.28      1.37    1.40 Inoperable Flow Dependent                    Figure 6 Power Dependent Fig. 13a    Fig. 13a    Fig. 14a Fig. 13a SLO    NSS Full Power      186          1.36      1:36    1,$ 5 Flow Depcndcnt                      None Power Dependent Fig. 7a    Fig. 7a    Fig. 8a  Fig. 7a SLO~VSSS Full Power      186          1.36      136      1.85 Flow Dependent                      None Power Dependent Fig. 9a    Fig. 9a    Fig. 10a Fig. 9a SLOP NSS RFr        Full Power      186          136        1.36    1.85 Inoperable Flow Dependent                      None Power Dependent Fig. 13a    Fig, 13a    Fig. 14a Fig, 13a
'ashington Nuclear-Unit    2                                                      COLR 92-8 Rev. 0
 
92%01 Table    lb WNP-2 Cycle 8 MCPR Operating Conditions Cycle Exposures > 4244 MWd/MT SLMCPR ~ 1.07m                        SLMCPR ~      1.07 FFfR SNP sx8    SNP 9x9    SNP 9x9 SVBA-96 SNP 8x8    SNP 9x9 SNP 9x9 SVBA-96 Condition Limit            GB11 LFA "            LFA              GB11 LFA            LFA Nssu)
Full Power      1.24      1.25      192      137    1.26      1.27      1.34   1.40 Flow Dependent                    Figurc 6                              Figure 6 Power Dependent Fig. 7b    Fig. 7b    Fig. 8b  Fig. 7b Fig. 11  Fig. 11  Fig. 12  Fig. 11 TSSS<'>
Full Power      1.28      1.29      138      1.43                Not Analyzed Flow Dependent                    Figure 6 Power Dependent Fig, 9b    Fig. 9b    Fig. 10b Fig. 9b NSSto RFI'ull Power              1.31      1.33      1.46      1.48                Not Analyzed inoperable Flow Dependent                ~  Figurc 6 Power Dependent  Fig. 13b  Fig. 13b  Fig. 14b Fig. 13b SLO(" NSS Full Power      186        1.36      1.36      1.85 - 1.56      1.36      136    1.85 Flow Dependent                      None                                  Noae Power Dependent Fig. 7b    Fig. 7b    Fig. 8b  Fig. 7b Fig. 11  Fig. 11    Fig. 12 Fig. 11 SLOmTSSS Full Power      1.56      1.36      1.36      1.85              Not Analyzed Flow Dependent                      None Power Depcadcat Fig. 9b    Fig. 9b    Fig. 10b Fig. 9b SLOP NSS RPT        Full Power      156        136        136      1.85                Not Analyzed Inoperable Flow Dependent                      None Power Dcpeadent Fig. 13b    Fig. 13b  Fig. 14b Fig. 13b W'ashington Nuclear-Unit 2                                                        COLR 92-8 Rev. 0
 
Notes for Table  1 Note 1: These MCPR values are based on the SNP Reload Safety Analysis performed using the control rod insertion times shown below (defined as normal scram speed: NSS). In the event that Surveillance 4.1.3.2 shows these scram insertion times have been exceeded, the plant thermal margin limits associated with NSS default to the values associated with the Technical Specification scram speed (TSSS). The scram insertion times must meet the requirements of Technical Specification 3.1.3.4.
Slowest measured average control rod insertion times t Position Inserted      specified notches for all operable control rods for each grou From Fully Withdrawn      of four control rods arranged in a two-by-two array (seconds)
Notch 45                                        0.380 Notch 39                                        0.690 Notch 25                                        1.500 Notch 5                                        2.750 Note 2: For Single Loop Operation, the SLMCPR increases by 0.01.
Note 3: The control rod withdrawal error (CRWB) analysis was performed with the nominal rod block monitor (RBM) setting value of 1.06. Use of the nominal setpoint is in accordance with the methodology described in Reference 5.12, consistent with approved industry practice. CRWH is limiting for the noted full power limits for cycle exposures less than 4244 MWd/MT. The load rejection without bypass (LRNB) event is limiting for the remaining full power events.
Washington Nuclear-Unit 2                                                  COLR 92-8 Rev. 0
 
m  f% g gg g%%%g
          %            wow g%        3 3333333333333                  ~
a            >>>>>>
3''"Em
                    ~  ~: ~
                                                ~ ~          ~
aaaaaaaaaaaa
                                                                                ~
5                                aC      a a I        I h<I I                                                El i      i          EE  hi<I      RRwwwawaaaeaaa
      ~El                I          hhsEi<          i El Isa<I
~ '>>            ~
                  ~  >>        ~ I'>>      I '>>        ~ ~ '>>    ~ g>>    ~ ~ '>>    ~ '>>
                                  \      ~ ~::      >>
 
w I g%%                                WWW %
g WWW                ~ o ~ s .. ~
F55
                                                                          ~ Ii
                                                                          %Kg 5RAR RP
                                                                          %AH
    ~5
                  ~ ~ ~  ~ ~ ~
                    ~ ~
        ~  I cl        555    CCCWOQRR            5
~ 'e      ~
4
                                      ~ ~
                                          '              ~
g 0  ~
                                                                    ~
                                            ~  ~
                                              ~ ~  ~ ~ :  .o
                                ~ ~ ~
                                  ~ ~
 
gaa
)P aaa RII aaa        aalu                IIIIIII
                                                                  ~i ~
I~I~
a ~ imp      I    ~            )I I11                  pI
                    %)$
ig>>
gmII
                                                                            ~
                                                                            )
50 s
                                                                                            ~  ~
                                                                                                ~ ~
s  ~
s
                                                                                                        ~
                                                                                                          ~
                                                                                                            ~I~~
                                                                                                              . s 55 aa                aaa a/a                  aaa g aaa                                          g~~
mh==-..l 5 QaC
          ~ ~
            ~
                  ~
                  ~
                        ~ ~  ~
I Ile I                            ~R            *1m          II I~
W' aa ala aaaa WRR gaa
                            ~  ~  ~  ~  ~
i'h)a I=~ma - Siilmm                                                  5 CCC RaC g,-l
                            ~  ~
    ~                                s
      ~
s      ~
hh I's s              I almlKIHillHIRIIIIBml
              ~  's                    ~
                                            '      ~ ~ 's      ~
                                                                '          ~ ~
BIN
                                                                                        ~
                                                                                          ~
s II        II'
                                                        ~ ~ ~
                                                                        ~ s:  . s
 
5%    58 55  855    WOO
                              %SR'O SOS aihh~il .IE      I li Iiii IIEEIEIEIIEIII  aalu IEI lij~P,  I    I  11    11 0%%
a S
a 8
I 580                8%
I 15 hh,.
ailli 515lallgiifP<I I Iiai I
                        %SR        OS%
al 0
I0 a h %OR        8RO    8    8 W 8 ~Q 0          0
    ~ I      I              I        wQgx ha<
w  a
..5955555551.555a55  I I aE.i.a              a  I I
 
a:a                                A s          ra            rrrr
                                                              %as rr r EaE      rrr rrr r r sa                rr 88 La err                I      ~  ~  I  ~ I
                                                              ~ 8                  ~  I  ~  ~  ~  . I rarh rrr >Ra RR7 E E QES rr r r                        rrrr rrr                                rr      ILS rrr rrr Ea                                rrr rrr                  err 5e r    r      rr rrr rrrr              rr rr rr              Irrr r er a                      55hlk r r                            r r rrr                      rrr aaa aa                                                  rrrrrr                    rrr              rrr aaa mm  $ &/&Mmmm
                  ~ ~ ~
ila                  iai            ilia.,aE I
    ~    I
    ~
    ~
        ~
aaa aaaaaaaa                                                < $ /a a I
II 'I Nallaaalliiillaiii
              ' 'i          ~ I'
                                  .          a              Iliaiii a~ ~
                                                                          '    ~
                                                                                    ~
EE
                                                                                                      ~ ~
                                  ~          ~        I      ~
I  ~
I    ~        I  I 0      . ~    ;    '    .
                                      ~    ~      ~    I
 
  'IP ag
              ~R Ilg  pl Sg 5R
      .M      55                                                                      ~    ~ I I    ~      I
    ~                                                                                    std I    ~  .  ~
m            RWRWWWWWWW%
I W            . hx-..                QQRRRRe A
      ~5      5 5  55                                                                              ~
Rl II~
I  '.
hgssss
          ~
                                                            ~  ~  ~        ~
I
                                                                                  ~  ~
                                                                ~  ~
S          RR      R    Q                  S            8      W            SOS      RRR
                                    ~  ~  'e          ~  'o            o ~  'o                      ~ ~
                                                      ~        ~
                                                  ~ ~
                                                          ~  ~
                                  ~ ~
                                          ~                          ~ I      I
                          ~ ~  ~      ~  ~  ~
                            ~  ~
 
gaa
              ~ 55 aa  I            I      RS%
Naa W
S WW S%
gga  SWO  IIa        g aa      gWSR RSRSaaa                    ~  ~ ~ ~ s.
SSO~ ISAAC                            aaa5 aaaawawwaaaa                QQR aaam        ar                SOS gaa                            ear
  ~ aa aalu  RWO WS I          SOS
                                                                                      ~ I raa ia. Iiii Pea maa
        ~ aa Imiha Lmma hpg $ 1.
E II:.. RRRHR QRR                              RES        Ia aalu 888 Raa    SQQ        ga
                                ~ kg Ile    khlhaa.h                              Ia E
SQS p          SOS'm C    -a%gg ha aa Ii                                        aaa
                                        ~  ~  ~    ~  ~  ~
mRil            aaa QSR  %SR  ala        RI        SR
                          ~ I 'o                  ~
                                                    ~
I          ~
g I
                                                                                  ~ I'i
                                      ~    ~
 
cR c
c c ~
c HER gSSR m W Icl
                                                      ~ s Ii
                                                          ~ ~ ~: . s ca 8  m    RwlR&#xc3;wwwwwQHQit c  I II SS    c.
58  Il5    ha; 58          ~
SO 'y      ~ ~ ~
cc
~c cc                          R Q cc ERR Ra~              c          c Sc&#xc3;S w    SgBQ)Rc clw      c a            ~
I'e                            la. I                  .I RQ cac ccc  IE
                      ~ ~ 'e II 8 0 SS
                                          ~ ~    ~
                                                    ~            ~ ~ 'i
                            ~      ~
 
ICC  EEE        E caa c52  EC2                          EEE        2        2 2 Cai                  EEEE EEEE EE iaa  EEEE            ~  I ~ ~ ~
EEEE SERI  RRRRL.22I EEE EL"QE          ECE QE      laiasseEEESEE EE EEE              EE CC2E ERE      SM          Sa  222  EEE    EE            EEE 2LI Cila                          ia  E E    EE EEE EE  r EER  E  E E  hh~J                                    RE%I
.ii            ~  ~  ~
ci        I SE2 CI aiba                                      LJ5 ICE CESS 2CRR
      ~      ~
aa'. E EEE E EE EEEE          E EEE    ha,    I iil  ~
      ~
I ~
CIEE I
I o
EI    E I2  EEE E
E E EES EEE EEEE SEEE EE    2          Iai    I22
                                                  ~
I al
                                                                  ~ 'o
 
g5    RCg  g g      55$          ~ Rg    gg55/gg) /QC/
89    E=R  a                      gM%%%
l
                                                  ~ ~
                                                      ~
                                                      ~
                                                        ~
                                                          ~
                                                          ~
                                                            ~
                                                              ~
                                                              . ~
55/
A5%          gWR hh            5W
                                                      ==5~        5 58$  8$                              J ~
gRI 5g )gag                $8 CRR  5 ma maaa Cml                  5g ae5 a~~ CmCm
~~5555~~55~1555555            g Wgg%% [HE            %&%
Hg&        %
W W
W                              g 5:
a
  'o              ~      I g<jg gg e RR1 0                    0 R %WA 5 WWRRha                    ml I
g
              ~ 's
                            ~    ~
 
8 il.
    ~ ah ORS WQ SWOR%      pOS I0            aa:
0 aaa    IPI ap ERa aalu OAR aalu SOS      S88
                                            ~              -I    RS      I~
aL Ia 5555 888 WSOWNS  8 Sh'0          8                  RQ  0 SOS      555        QS RER aaI                                                          aaa La            WQQ QQR I:I      aal wl aa aas 2+l      E al  SS      SS
      ~a ad%
Ila ia. I I        la0 gl    0 SR SQS lia      all WS L
aa
~ 'e          ~ o          ~ ~ 'a                            ~
                                                                ~    ~
                                                                        ~    I~ 's
                                  ~      e      ~      ~
                                        ~  i    . s
                              ~      I        ~  ~  ~
                                    ~  ~    ~
 
k      kk kk  k              k  Q    kkk F        I  I .I                IIla    ~'II III I 8      IIa III II Im ESESRRSSRRSR Ii I ~I I                      RS WRSggR WWLRLC I
a 5 ~
    ~iIIIiIL'IIlllih INN g)l 5                        aa kk k
II I.hh;.      ,I mhhp%$
I          /p mr~    I        Il
      ~
                    ~  I'o            ~ ~      ~
                                                    ~      I~ 'o I ~
                      ~  ~    ~
 
SgO                S        8        ES8 Igg  p$ pgg      g 51              m~l5        RWKWKHWHR gIC gS rr SS Ill gal%
aiba                      apl gR g RRI                    g                              g    gggg aaSQ                      0 o    ~  ~    ~  ~  o III 8 R SSR                                                  Q    %8 Ilg    ~ 55          S            SOS        aS S8 R    SO SOS gag          ~ EW
              $ 15        ~8 gE              gSE SE        LR IWg      Ep g
I al8 aaa y
4 IR ha    t al g
                                        ~
HhHa f
                                                ~
                                                    ~        ~ ~
8
                              ~ ~
                                      ~
 
k kk kk kkk ~
g'%g ~ kk ~ k        k kk  laa laal    II ~ I kkk  Qaa kkk kh>
Ila a kW k 5
                        ~ al k  55M
                              ~ ~
II IL ARR III kkk kkk kk    k 5 aaaI  IL  lla  aa kkkk la                      I aa IaaaII laI 'Iaa lllahmla Iaal    ll L
I ~ 'i                  I I haa<III    I OS I
kI
      ~
I  ~    ~ ~
k        Ik  Ik
 
ak    SSS      S          ~          R S  S S a                        a ilk SQS SS      S              S SS SS c
ak Slays/
l'l
                                                    ~ I ~
SSS SSS
~ ak  kaa    Illa kkk a~
S a:i  ala              'a ASS
        ~ kk
        ~ kk    Lkgk        kkk    ak
                                  ~ ak ASS  Si        Ilk  kl
                                                          ~ kk SSS SSS XSS ASS SSAII
        ~ ll SSS    SSh Q g S lla F.                  ~ kl SSS SS SS ISSS
                                                  ~
a
~ ka    SS    SSS          SOS SS  SS SSS
~ ka  I                                i(k 'a kkk      SS
                                                        ~
SSS
                                                                ~
SSS
            ~ ~    ~ I                    ha              a Iak lll SSS
        ~
RES 5IINIIHI                ~  kl  SSS                  S SS SSS akk SSS    SSS    SS            SS SSS
                                  ~ ak SSS
                                        'aii ll ASS SSSS S    SS kkkgk SSa
                                                        ~ ak q kk S
SSS SWISS      SSS          SSS  SSS    SSSS  SSS      SSS    S S I 'o
 
920701 4.0    Linear Heat Generation Rate (LHGR) Limit for Use in Technical Specification 3.2.4 The LHGR limit for use in Technical'Specification 3.2.4 shall not exceed the values shown in Figures 15, 16, 17, 18, and 19.
Washington Nuclear-Unit 2                                          COLR 92-8 Rev. 0
 
DIES    ESgSSEgE      Smg    EpE 0 8        SS                I Iil ill                                    il  liei~lll          ii  L~
'' I  Ill      Ill                              E IEgs gism%
REL 851i LR
                                                                      )san    gs I Ia Ig                                    I~  )'.ii Ii.                  i.
Ill ae Psa E~1 5555555a555 sa5  NS BL p      Ill  CII
                                              ..I IIIiii lul hii hau B5:.
RI~ 1<ggl1 I      ~ ~ I    I ~ II  ~ II I I
                                  ~    ~  'I ~ ~  ~      II ~ ~
I ~ ~ ~    I~ I  ~ I~ I
 
I'I II I I I I~ IgII    gII I            Ii  IIIII
                                      .I:.I:
ailllll Ill      I
                                    ~          i:IIIIII III ~ I SmkSISS5
  ~ ~  EH$
NSNNARSm Rmh'cl RNm sk N SNmmmw 50k'    Nmmsmmms  Nlm PPI                          IIII A iiQRAm I!'!ill  5 8 I
1,.
II
                                      ~ I  m  m I  SE Ia
                                                          ~
        - ''    '-                IQIRMR
                                      "'-lil  REIRmgI  IRRER I
I!maim
                          -    ll              i"i" IIIIII
                                                        ~
                                    ~ IIllhh50iRRIRIIII aLslaa ming>iARi
                            ,i. I IIILIIIR    LIhhlls $ IIIL Is IRRIRERI PREWRPlgRII  ~
~  Ill SSaaraaaaaaaaarar WNAA                        NAS  IIIIIIII IIILIIIR4L. SR RNNRiASS                Wi NARON IIII!illiI!i'.Ill! !I!11 ii
 
g aaaRaEQEggaaap)EEE              5  aa OSWSR    55 NSSSN 55 RS555 55        QiiSSRSSSiSSSSNSiRSRR        iiSSSR SOS  SQS    ASS>Iso' SSA N %RID a aa2aaiahgg 5
NSWiSN S
      ~ ggaagp    rnsuL AS %SEAR SIQSNNOO RANNSRNS ESSSSOSS AkS S RN aa  0 QRO                ass        Ia awmmrraa
~
  ~
ISSSSASS        I  ~  I
                                                ~ SRSSIk%5    IQSkSSSE11%1191%
Iia
  ,  aiiiiilalialiallliIElillilal lli.laaii aalalia.                    liil.ah..
  ~
alaiaiii liia
                ~ ~ ~
ill ~  ~ ~ ~
I en
                                            ~ ~ ~ ~
I iii Iiilll I
                                                        ~ ~ ~          ~
ialliii II      ~ ~ ~ I~
 
A Akk kk k            A                IIIimamilmmaaaIIIam
                                      .aalm aa aeaemm kkkkkk %%%%%%&$ 5%                  IISIIII kkkkkkkk  aCRamaas Akkkkk kkkkkkkk Akk MAX kk kkkk AWAA kkkr kAkkkkk      .        I; A
A  kkkkkkkkkk kkkkkkkk Akkk A amIRLa kkkkkk RIRIaa kkkkkkkk kkkkkk    s    I  ~  ~
I III WAMkkkkk Akkkkkk rkr  kkkk Akk MWW k kk k      Wk WWAAAAAXM kkkkkk kkkkkkkkk Akkkkk  W k
akkkkkkkkk  al r kkk sar Ia Akkkk aaa Akkkkkk        ARAA              kk I ~ ~ I
 
kkkSkkkkkkkkkk          )kg kk k kgkkkkkk                  g  kk
, haaKaiba        aaL11 1      Rs1 11as          sLassa1          1 1 s a s1sagagpgggassm            saass1I          sggsgsg          am ~
g                              ILas1s
  ~ sgsaa1s IgssgSChsh 11                                a 11 11
                                                                        ~ s1~
asRaRaa
                ~ s s                          sassssmLs as
~
is            ~)gas      s1sa              a k
I1 k kkk 1
kkk  k          k II I~II k $i  .e:Ik E
kk      kkkk I
I1  iiiii'-'-.-".,            ~    hh      h5imi      1    l1i    1.
kkkkkkkk                          ~ sass kkkkk    sassafras kkkkkkl~k      a1al1 ask LNLS:
OOOEkkkk O kkk kk
  ~  sasasa      ggilgip        I ROSE ua1 1raaas1 NsCa      asCs1L ONkkkkN kkkkkkkl. MOOOOEE O Iialggi haslLuah 1 a1aa sassa]ss ~ pa)lass
~  L1111 kk k kkk 11 kk ssLSRR      aasRaaL k        kk      sssLCs18 kk k kkk kkkkk      shah'. I
              ~ iii      ~ ~ ~ ~            ~ iii        ~ i ~ ii            ~ ~ ~
 
92070l 5.0  References 5.1  EMF-92-039, Revision 1, WNP-2 Cycle 8 Plant Transient Analysis, Siemens Nuclear Power Corporation, June 1992.
5.2  EMF-92-040, Revision 1, WNP-2 Cycle 8 Reload Analysis, Siemens Nuclear Power Corporation, June 1992.
5.3  GE11 Lead Fuel Assembly Report for Washington Public Power Supply System Nuclear Project No. 2, Reload 5, Cycle 6, General Electric Company, December 1989 (Proprietary).
5.4  UK 90-126, Supplemental Lead Fuel Assembly Licensing Report  SVE'A-96LFA's for WNP-2,  ABB Atom, January 1990 (Proprietary).
5.5  ATOP-91-120, W. R. Harris, ABB, to D. L. Whitcomb, Supply System, Assembly Treatment in WNP-2 Cycle 7 Core Operating Limits Report, May 1, 1991.
5.6  SNPWP-92-0059, Udell Fresk, Siemens Nuclear Power Corporation, to R. A. Vopalensky, Supply System, Comments on WNP-2 Cycle 8 Draft COLR Report, May 21, 1992.
5.7  JTW:92-087, J. T. Worthington, General Electric Company, to D. L. Whitcomb, Supply System, WNP-2 Cycle 8 Core Operating Limits Report, Contract No.
C-21099, Gall Lead Fuel Assemblies, May 22, 1992.
5.8  ATOP-92-062, W. R. Harris, ABB Atom, to D. L. Whitcomb, Supply System, SVE'A-96 Lead Fuel Assembly Treatment in'WNP-2 Cycle 8 Core Operating Limits Report, May 15, 1992.
5.9  SNPWP-92-0072, Udell Fresk, Siemens Nuclear Power Corporation, to R. A. Vopalensky, Power Dependent MCPR Limitsfor WNP-2 Cycle 8, June 24, 1992.
5.10  ANF-89-014(P)(A), Revision 1 and Supplement 1 & 2, Generic Mechanical Design for Advanced Nuclear Fuels 9'-1X and 9x9-9X Reload Fuel, Advanced Nuclear Fuels Corporation, Richland, WA, October 1991.
5.11  XN-NF-79-71(P), Revision 2, including Supplements 1,2 and 3(A), Enon Nuclear Plant Transient Methodology for Boiling Water Reactors, Exxon Nuclear Company, Inc., Richland, WA, November 1981.
5.12  XN-NF-80-19(P)(A), Volume 1 Supplement 1 and 2, Exron Nuclear Methodology for Boiling Water Reactors Neutronic Methods for Design Analysis, March 1983.
Washington Nuclear-Unit 2                                          COLR 92-8 Rev. 0
 
5.13 i                    92%01 XN-NF-80-19(P)(A), Volume 1 Supplements 3 and 4, Exxon Nuclear Methodology for Boiling Water Reactors Neutronic Methods for Design Analysis, Advanced Nuclear Fuels Corporation, Richland, WA, November 1990.
5.14  XN-NF-80-19(P)(A), Volume 3, Revision 2, Exxon Nuclear Methodology for Boiling Water Reactors THERMEK Thermal Limits Methodology Summary Description, Exxon Nuclear Company, Inc., Richland, WA, January 1987.
5.15  XN-NF-80-19(P)(A), Volume 4, Revision 1, Exxon Nuclear Methodology for Boiling Water Reactors: Application of the ENC Methodology to BWR Reloads, Exxon Nuclear Company, Inc., Richland, WA, June 1986.
5.16  ANF-913(P)(A), Volume 1, Revision 1 and Volume 1, Supplements 2, 3, and 4, COTRANSA2: A Computer Program for Boiling Water Reactor Transient Analyses, Advanced Nuclear Fuels Corporation, Richland, WA, August 1990.
5.17  ANF-524(P)(A), Revision 2 and Supplements 1 and 2, Advanced Nuclear Fuels Critical Power Methodology for Boiling Water Reactors, Advanced Nuclear Fuels Corporation, Richland, WA, November 1990.
5.18  ANF-1125(P)(A) and Supplements 1 and 2, ANFB Crirical Power Correlation, Advanced Nuclear Fuels Corporation, Richland, WA, April 1990 5.19  Letter, R. C. Jones (NRC) to R. A. Copeland (ANF), NRC Approval    of ANFB Additive Constants for 5%9-5K BWR Fuel, November 14, 1990.
5.20  Letter ENWB-96-0067, J. B. Edgar (ANF) to Supply System, Supplemental Licensing Analysis Results, April 15, 1986.
5.21  ANF-90-01, WNP-2 Cycle 6 Plant Transient Analysis, Advanced Nuclear Fuels Corporation, Richland, WA, January 1990.
5.22  XN-NF-84-105(P)(A), Volume    1  and Supplements  1, 2, & 4, XCOBRA-T: A Computer Code for BWR Transient Thermal Hydraulic Core Analysis, Exxon Nuclear Company, Inc., Richland, WA, February 1987.
5.23  XN-NF-81-21(P)(A), Revision 1, Generic Mechanical Design for Exxon Nuclear Jet Pump BWR Relouf Fuel, Exxon Nuclear Company, Inc., Richland, WA, September 1982, and Supplement 1, March 1985.
5.24  XN-NF-85-67(P)(A), Revision 1, Generic Mechanical Design for Exxon Nuclear Jet Pump BWR Reload Fuel, Exxon Nuclear Company, Inc., Richland, WA, September 1986.
Washington Nuclear-Unit 2                                        COLR 92-8 Rev. 0
 
5.25  TAC M83319, Docket 50-397, Proposed Bx8 Fuel Burnup Extension for Cycle 8  WNP-2 PAC No. M83319), R. R. Assa, NRC, to G. C. Sorensen, July 1, 1992.
5.26  XN-NF-81-58(A), Revision 2, RODEX2: Fuel Rod Mechanical Response Evaluation Model, Exxon Nuclear Company, Inc., Richland, WA, March 1984.
5.27  XN-NF-87-92 and Supplement 1, WNP-2 Plant Transient Analysis With Final Feedwater Temperature Reduction, Advanced Nuclear Fuels Corporation, Richland, WA, June 1987'and May 1988.
5.28  ANF-87-119, WNP-2 Single Loop Operation Analysis, Advanced Nuclear Fuels Corporation, Richland, WA, September 1987.
5.29  ANF-87-118, WNP-2 LOCA Analysis For Single Loop Operation, Advanced Nuclear Fuels Corporation, Richland, WA, September 1987.
5.30  Letter, R. B. Samworth, USNRC, to G. C. Sorensen, Supply System, Issuance ofAmendment No. 62 to Facility Operating License No. NPF-21-WPPSS Nuclear Project 2 (TAC No. 67538), August 5, 1988.
5.31  XN-NF-85-138(P),LOCA Break Spectrum    for a BWR 5, Exxon Nuclear Company, Inc., Richland, WA, December 1985.
5.32  XN-NF-85-139, WNP-2 LOCA-ECCS Analysis, MAPLHGR Results,            Exxon Nuclear Company, Inc., Richland, WA, December 1984.
5.33  ANF-CC-33(P)(A), Supplement 2, HLXY: A Generalized Multirod Heatup Code with 10 CFR SOAppendix ZHeatup Option, Advanced Nuclear Fuels Corporation, Richland, WA, January 1991.
5.34  XN-NF-81-22(P)(A), Generic Statistical Uncertainty Analysis Methodology, November 1983.
5.35  NEDE-24011-P-A-6, General Elecmc Standard Application for Reactor Fuel, April 1983.
Washington Nuclear-Unit 2                                       COLR 92-8 Rev. 0}}

Latest revision as of 06:37, 4 February 2020

Rev 0 to Washington Nuclear Plant 2 Cycle 8,Core Operating Limits Rept.
ML17289A722
Person / Time
Site: Columbia Energy Northwest icon.png
Issue date: 06/30/1992
From:
WASHINGTON PUBLIC POWER SUPPLY SYSTEM
To:
Shared Package
ML17289A721 List:
References
COLR-92-8, COLR-92-8-R, COLR-92-8-R00, NUDOCS 9207150308
Download: ML17289A722 (41)


Text

9207 0l COLR 92-8 Rev. 0 Controlled Copy No.

WNP-2 Cycle 8 Core Operating Limits Report June 1992 Washington Public Power Supply System 9207150308 92070b PDR ADOGY 05000397 PDg P-

I 1

r

920701 WNP-2 Cycle 8 Core Operating Limits Report List of Effective Pages

~Pa e ~Reviei 1 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 10 0 11 0 12 0 13 0 14 0 15 0 16 0 17 0 18 0 19 0 20 0 21 0 22 0 ~

23 0 24 0 25 0 26 0 27 0 28 0 29 0 30 0 31 0 32 0 33 0 34 0 35 0

I 920701 WNP-2 Cycle 8 Core Operating Limits Report Table of Contents

~Pa ~e 1.0 Introduction and Summary .................................. 1 2.0 Average Planar Linear Heat Generation Rate (APLHGR) Limits for Use in Technical Specification 3.2.1................................. 2 e

'3.0 Mnmnum Critical Power Ratio (MCPR) Limit for Use in Technical

~ g S pecuicahon 1J 3.2.3 ....................................... 8 4.0 Linear Heat Generation Rate (LHGR) Limit for Use in Technical pecuicabon3.2.4 ....................,.............,....

g\ 27

~

S 1J 5..0 References ....................................... .. .. ~ 33 W'ashington Nuclear-Unit 2 COLR 92-8 Rev. 0

I 920701 1.0 Introduction and Suxnlnary This report provides the Average Planar Linear Heat Generation Rate (APLHGR) limits, the Mnimum Critical Power Ratio (MCPR) limits, and the Linear Heat Generation Rate (LHGR) limits for WNP-2, Cycle 8 as required by Technical Specification 6.9.3.1. As required by Technical Specifications 6.9.3.2 and 6.9.3.3, these limits were determined using NRC-approved methodology and are established so that all applicable limits of the plant safety analysis are met. The thermal limits for SNP fuel given in this report are documented in the Cycle 8 Plant Transient Analysis Report (Reference 5.1), the Cycle 8 Reload Analysis Report (Reference 5.2), and the Power Dependent MCPR Limits for WÃP-2 Cycle 8 letter report (Reference 5.9). The thermal limits determined through the approved methodology are modified for the GE11 and SVEA-96 LFA's as discussed below.

The WNP-2 Cycle 8 reload will include four Siemens Nuclear Power (SNP), four General Electric (GE), and four ABB Atom (ABB) Lead Fuel Assemblies (LFA's). The four SNP LFA's were inserted during the reload for Cycle 5. The four GE and ABB LFA's were inserted at the beginning of Cycle 6 and were designed to be compatible with the reload fuel utilized in Cycle 6. The Supply System willload the LFA's in core locations which, according to analysis, have sufficient margin such that the LFA's are not expected to be the limiting assemblies. This approach is intended to exclude the LFA's ever being the limiting fuel assemblies on either a nodal or an assembly power basis. The GE11 LFA is described in the GEll Lead Fuel Assembly Report for washington Public Power Supply System Nuclear Project No. 2, Reload 5, Cycle 6 (Reference 5.3). This reference describes the design goals of the GE11 LFA's and provides support for monitoring the GE11 LFA's at thermal limits based on the SNP 8x8 reload fuel thermal limits. The SVEA-96 LFA is described in the Supplemental LFA Licensing Report SVZA-96LFA's for TVÃP-2 (Reference 5.4). The process for developing thermal limits for the SVEA-96 LFA fuel based upon the SNP 8x8 reload fuel thermal limits is described in this reference and Reference 5.5.

The MAPLHGR limits for the GE11 LFA's are the same as the SNP 8x8 reload fuel, except that a ratio ([64-2]/[81-7]) is applied to account for the different number of fuel pins in the two designs. The MAPLHGR limits for the SVEA-96 LFA's are the same as the SNP 8x8 reload fuel, except that a ratio ([64-2]/[100-4]) is applied to account for the different number of fuel pins in the two designs. Furthermore, the MAPLHGR limits for the SVEA-96 LFA's are multiplied 1) by 1.04 to account for a different estimation of the local power in the output from POWERPLEK compared to ABB 'Atom methods and 2) by 1.02 to account for a different estimation of exposure in the output from POVFEM'LEX compared ABB Atom methods. This produces a combined multiplier of 1.06.

A power dependent MCPR is specified in this report to define operating limits at other than rated power conditions. For the WNP-2 core, feedwater-controller-failure transients from reduced power are calculated to be more severe than from full power conditions. A flow dependent MCPR is specified in this report to define operating limits at other than rated flow conditions. The reduced flow MCPR operating limit provides bounding protection for the limiting recirculation flow increase transient. At less than rated conditions, the MCPR limit is the maximum of the rated power MCPR limit, the reduced power MCPR limit, and the reduced Washington Nuclear-Unit 2 COLR 92-8 Rev. 0

920701 flow MCPR limit. This stipulation assures that the safety limit MCPR will not be violated throughout the WNP-2 operating regime.

The LHGR limits for the GEl1 LFA's are the same as the SNP 8x8 reload fuel, except that a ratio ([64-2]/[81-7]) is applied to account for the different number of fuel pins in the two designs. The LHGR limits for the SVEA-96 LFA's are taken directly from Reference 5.4.

Preparation, review and approval of this report were performed in accordance with applicable Supply System procedures. The specific topical report revisions and supplements which describe the methodology utilized in this cycle specific analysis are referenced in Section 5.0 2.0 Average Planar Linear Heat Generation Rate (APLHGR) Limits for Use in Technical Specification 3.2.1 The APLHGR's for use in Technical Specification 3.2.1 shall not exceed the limits shown in Figures 1, 2, 4, and 5 when in two-loop operation.and in Figures 1, 3, 4, and 5 when in single loop operation. The limits for each fuel type as a function of Average Planar Exposure are provided for the Siemens Nuclear Power fuel, including the SNP LFA's, the SVEA-96 LFA fuel, and the GE11 LFA fuel.

Washington Nuclear-Unit 2 COLR 92-8 Rev. 0

HRIIIR~I=L+aHHHIHHHRh5-:~=IIIIIIIEIIIIIIII

, I'IIIIP=lie--IIIIIII=11155al "

'i55151:ill:sillls5lilliliIN I-.i=li'> IIP=-lillllIIIIINN5=---!IIIIIIIIIII 11:sllil-=5111 IillllllPI111515h~~e~gllailll5115

, 1=.,-511 5111111555115sllll','=ll-=h~liillli III

, 111111 Isilills=*llialh'Hillillsl IIIIIII IIIIIR: I!1155~151llalR'Hlllllal 51551115111Ãllllhlllllll IIIIII), lilllll

., IIIIIII Illsiliilllh55515 1155 115111111511115 alii IIII Illlllllllllili

,, IIIIIII 155I 515lllilhmumnn Illlllllllllllllllll Illf

5 I  %%Kg Q A gR A/A Bl I:ILa a I a II g

I i>a I

I I hh.

B ma a aam am a '%$1

~ I gM M a

all 111 laa hi. wealIa CC l1i Iwq ala am Q R I.a Ia R Iia I5 R

~aaL'W a 2 alia ah%

Ima I.R im <I ll ~ III aal III a

l a==:IIPallllHI Ima

~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

055 t~~ ~ ~ ~ ~ ~ ~ ~ ~ ~ III ~

~ II

IBRBBeBRRRBRRRRR 8 IB

'I

= RRg I

IIRR BRAN R~~

II

=g IB IR lailm IL 1 a I.'1 I~ 1 h% 1181811111 gg I~

1 Bh<

e=L IR~

RI

=

'1 18 ~aBa 1=1 8 11 a a 1

a RR wC 5

... .: I

' CC 88~

a=I e-=i kaa 1 I

g- III o ~ e I I II RI "I.

I' i I~ I I~

1 1 Ram IR

~ ~ ~ ~ ~ ~ ~ ~ I~ ~ ~ ~ ~

I-= IS: SSSIIISS= 11 SIISISSSSSII

., IIIIIISIIISIIIIIISSI5llMISSSISSS NSIIL~S SSIISIIIISSSSSIlhlSSIISI

, Illlilllllllli 11; 15555555a55555 II ...'..

PAIII Illhil IISISI 555511:~555~5'=ll I~"

55555, IISSII<-iII<5 SlIP 555551, 555555 Sl I IIIIII IIISI 55555555555>55515515 Ill.i ....... 11115 55.55~55555555

'lllllllllllllllllll llllllllllllll

~ ~ ~

,'ii 11: illl-11111111- a5555iRRi555

, O'.1 SR==i-551~51151i55--RRSR illllll

=:=-=555= 111111

'l s ~ s-

~ ~

., 1= ',ll R=,-arne=-aa- 5554%

, SSsRSI R SERAI 111111

~ .

'" ll:-111-=:illllll Sil'.ll.='=RRRPi555555 1 li551='RRii'555555 1 I-Rhh>mnmm 1 =-=55-==-55>Ra555555

.,11 555 =11111111illl 111 11111111

920701 3.0 MinimUm Critical Power Ratio (MCPR) Limit for Use in Technical Specification 3.2.3 The MCPR limit for use in Technical Specification 3.2.3 shall be:

a) Greater than or equal to the greater of the limits determined from Tables la and 1b and Figures 6 and 7a through 14b.

b) The full power limit is determined at 104% power and 106% core flow.

Washington Nuclear-Unit 2 COLR 92-8 Rev. 0

Table la WNP-2 Cycle 8 MCPR Operating Conditions Cycle Exposures ( 4244 MWd/MT SLMCPR ~ 1,07+

SNP 8xg SNP 9x9 SNP 9x9 SVEA-96 Condition Limit GF.11 LFA LFA Nss'"

Full Power 1.23+ 1.23+ 1,25 136+

Flow Dependent Figure 6 Power Dependent Fig. 7a Fig. 7a Fig. 8a Fig, 7a Tsss~n Full Power 1.24 1.25 1.32 1.37 Flow Depcndcnt Figure 6 Power Dependent Fig. 9a Fig, 9a Fig. 10a Fig. 9a Nssu~

RFI'ull Power 1.26 1.28 1.37 1.40 Inoperable Flow Dependent Figure 6 Power Dependent Fig. 13a Fig. 13a Fig. 14a Fig. 13a SLO NSS Full Power 186 1.36 1:36 1,$ 5 Flow Depcndcnt None Power Dependent Fig. 7a Fig. 7a Fig. 8a Fig. 7a SLO~VSSS Full Power 186 1.36 136 1.85 Flow Dependent None Power Dependent Fig. 9a Fig. 9a Fig. 10a Fig. 9a SLOP NSS RFr Full Power 186 136 1.36 1.85 Inoperable Flow Dependent None Power Dependent Fig. 13a Fig, 13a Fig. 14a Fig, 13a

'ashington Nuclear-Unit 2 COLR 92-8 Rev. 0

92%01 Table lb WNP-2 Cycle 8 MCPR Operating Conditions Cycle Exposures > 4244 MWd/MT SLMCPR ~ 1.07m SLMCPR ~ 1.07 FFfR SNP sx8 SNP 9x9 SNP 9x9 SVBA-96 SNP 8x8 SNP 9x9 SNP 9x9 SVBA-96 Condition Limit GB11 LFA " LFA GB11 LFA LFA Nssu)

Full Power 1.24 1.25 192 137 1.26 1.27 1.34 1.40 Flow Dependent Figurc 6 Figure 6 Power Dependent Fig. 7b Fig. 7b Fig. 8b Fig. 7b Fig. 11 Fig. 11 Fig. 12 Fig. 11 TSSS<'>

Full Power 1.28 1.29 138 1.43 Not Analyzed Flow Dependent Figure 6 Power Dependent Fig, 9b Fig. 9b Fig. 10b Fig. 9b NSSto RFI'ull Power 1.31 1.33 1.46 1.48 Not Analyzed inoperable Flow Dependent ~ Figurc 6 Power Dependent Fig. 13b Fig. 13b Fig. 14b Fig. 13b SLO(" NSS Full Power 186 1.36 1.36 1.85 - 1.56 1.36 136 1.85 Flow Dependent None Noae Power Dependent Fig. 7b Fig. 7b Fig. 8b Fig. 7b Fig. 11 Fig. 11 Fig. 12 Fig. 11 SLOmTSSS Full Power 1.56 1.36 1.36 1.85 Not Analyzed Flow Dependent None Power Depcadcat Fig. 9b Fig. 9b Fig. 10b Fig. 9b SLOP NSS RPT Full Power 156 136 136 1.85 Not Analyzed Inoperable Flow Dependent None Power Dcpeadent Fig. 13b Fig. 13b Fig. 14b Fig. 13b W'ashington Nuclear-Unit 2 COLR 92-8 Rev. 0

Notes for Table 1 Note 1: These MCPR values are based on the SNP Reload Safety Analysis performed using the control rod insertion times shown below (defined as normal scram speed: NSS). In the event that Surveillance 4.1.3.2 shows these scram insertion times have been exceeded, the plant thermal margin limits associated with NSS default to the values associated with the Technical Specification scram speed (TSSS). The scram insertion times must meet the requirements of Technical Specification 3.1.3.4.

Slowest measured average control rod insertion times t Position Inserted specified notches for all operable control rods for each grou From Fully Withdrawn of four control rods arranged in a two-by-two array (seconds)

Notch 45 0.380 Notch 39 0.690 Notch 25 1.500 Notch 5 2.750 Note 2: For Single Loop Operation, the SLMCPR increases by 0.01.

Note 3: The control rod withdrawal error (CRWB) analysis was performed with the nominal rod block monitor (RBM) setting value of 1.06. Use of the nominal setpoint is in accordance with the methodology described in Reference 5.12, consistent with approved industry practice. CRWH is limiting for the noted full power limits for cycle exposures less than 4244 MWd/MT. The load rejection without bypass (LRNB) event is limiting for the remaining full power events.

Washington Nuclear-Unit 2 COLR 92-8 Rev. 0

m f% g gg g%%%g

% wow g% 3 3333333333333 ~

a >>>>>>

3"Em

~ ~: ~

~ ~ ~

aaaaaaaaaaaa

~

5 aC a a I I h<I I El i i EE hi<I RRwwwawaaaeaaa

~El I hhsEi< i El Isa> ~

~ >> ~ I'>> I '>> ~ ~ '>> ~ g>> ~ ~ '>> ~ '>>

\ ~ ~:: >>

w I g%% WWW %

g WWW ~ o ~ s .. ~

F55

~ Ii

%Kg 5RAR RP

%AH

~5

~ ~ ~ ~ ~ ~

~ ~

~ I cl 555 CCCWOQRR 5

~ 'e ~

4

~ ~

' ~

g 0 ~

~

~ ~

~ ~ ~ ~ : .o

~ ~ ~

~ ~

gaa

)P aaa RII aaa aalu IIIIIII

~i ~

I~I~

a ~ imp I ~ )I I11 pI

%)$

ig>>

gmII

~

)

50 s

~ ~

~ ~

s ~

s

~

~

~I~~

. s 55 aa aaa a/a aaa g aaa g~~

mh==-..l 5 QaC

~ ~

~

~

~

~ ~ ~

I Ile I ~R *1m II I~

W' aa ala aaaa WRR gaa

~ ~ ~ ~ ~

i'h)a I=~ma - Siilmm 5 CCC RaC g,-l

~ ~

~ s

~

s ~

hh I's s I almlKIHillHIRIIIIBml

~ 's ~

' ~ ~ 's ~

' ~ ~

BIN

~

~

s II II'

~ ~ ~

~ s: . s

5% 58 55 855 WOO

%SR'O SOS aihh~il .IE I li Iiii IIEEIEIEIIEIII aalu IEI lij~P, I I 11 11 0%%

a S

a 8

I 580 8%

I 15 hh,.

ailli 515lallgiifP<I I Iiai I

%SR OS%

al 0

I0 a h %OR 8RO 8 8 W 8 ~Q 0 0

~ I I I wQgx ha<

w a

..5955555551.555a55 I I aE.i.a a I I

a:a A s ra rrrr

%as rr r EaE rrr rrr r r sa rr 88 La err I ~ ~ I ~ I

~ 8 ~ I ~ ~ ~ . I rarh rrr >Ra RR7 E E QES rr r r rrrr rrr rr ILS rrr rrr Ea rrr rrr err 5e r r rr rrr rrrr rr rr rr Irrr r er a 55hlk r r r r rrr rrr aaa aa rrrrrr rrr rrr aaa mm $ &/&Mmmm

~ ~ ~

ila iai ilia.,aE I

~ I

~

~

~

aaa aaaaaaaa < $ /a a I

II 'I Nallaaalliiillaiii

' 'i ~ I'

. a Iliaiii a~ ~

' ~

~

EE

~ ~

~ ~ I ~

I ~

I ~ I I 0 . ~  ; ' .

~ ~ ~ I

'IP ag

~R Ilg pl Sg 5R

.M 55 ~ ~ I I ~ I

~ std I ~ . ~

m RWRWWWWWWW%

I W . hx-.. QQRRRRe A

~5 5 5 55 ~

Rl II~

I '.

hgssss

~

~ ~ ~ ~

I

~ ~

~ ~

S RR R Q S 8 W SOS RRR

~ ~ 'e ~ 'o o ~ 'o ~ ~

~ ~

~ ~

~ ~

~ ~

~ ~ I I

~ ~ ~ ~ ~ ~

~ ~

gaa

~ 55 aa I I RS%

Naa W

S WW S%

gga SWO IIa g aa gWSR RSRSaaa ~ ~ ~ ~ s.

SSO~ ISAAC aaa5 aaaawawwaaaa QQR aaam ar SOS gaa ear

~ aa aalu RWO WS I SOS

~ I raa ia. Iiii Pea maa

~ aa Imiha Lmma hpg $ 1.

E II:.. RRRHR QRR RES Ia aalu 888 Raa SQQ ga

~ kg Ile khlhaa.h Ia E

SQS p SOS'm C -a%gg ha aa Ii aaa

~ ~ ~ ~ ~ ~

mRil aaa QSR %SR ala RI SR

~ I 'o ~

~

I ~

g I

~ I'i

~ ~

cR c

c c ~

c HER gSSR m W Icl

~ s Ii

~ ~ ~: . s ca 8 m RwlRÃwwwwwQHQit c I II SS c.

58 Il5 ha; 58 ~

SO 'y ~ ~ ~

cc

~c cc R Q cc ERR Ra~ c c ScÃS w SgBQ)Rc clw c a ~

I'e la. I .I RQ cac ccc IE

~ ~ 'e II 8 0 SS

~ ~ ~

~ ~ ~ 'i

~ ~

ICC EEE E caa c52 EC2 EEE 2 2 2 Cai EEEE EEEE EE iaa EEEE ~ I ~ ~ ~

EEEE SERI RRRRL.22I EEE EL"QE ECE QE laiasseEEESEE EE EEE EE CC2E ERE SM Sa 222 EEE EE EEE 2LI Cila ia E E EE EEE EE r EER E E E hh~J RE%I

.ii ~ ~ ~

ci I SE2 CI aiba LJ5 ICE CESS 2CRR

~ ~

aa'. E EEE E EE EEEE E EEE ha, I iil ~

~

I ~

CIEE I

I o

EI E I2 EEE E

E E EES EEE EEEE SEEE EE 2 Iai I22

~

I al

~ 'o

g5 RCg g g 55$ ~ Rg gg55/gg) /QC/

89 E=R a gM%%%

l

~ ~

~

~

~

~

~

~

~

. ~

55/

A5% gWR hh 5W

==5~ 5 58$ 8$ J ~

gRI 5g )gag $8 CRR 5 ma maaa Cml 5g ae5 a~~ CmCm

~~5555~~55~1555555 g Wgg%% [HE  %&%

Hg&  %

W W

W g 5:

a

'o ~ I g<jg gg e RR1 0 0 R %WA 5 WWRRha ml I

g

~ 's

~ ~

8 il.

~ ah ORS WQ SWOR% pOS I0 aa:

0 aaa IPI ap ERa aalu OAR aalu SOS S88

~ -I RS I~

aL Ia 5555 888 WSOWNS 8 Sh'0 8 RQ 0 SOS 555 QS RER aaI aaa La WQQ QQR I:I aal wl aa aas 2+l E al SS SS

~a ad%

Ila ia. I I la0 gl 0 SR SQS lia all WS L

aa

~ 'e ~ o ~ ~ 'a ~

~ ~

~ I~ 's

~ e ~ ~

~ i . s

~ I ~ ~ ~

~ ~ ~

k kk kk k k Q kkk F I I .I IIla ~'II III I 8 IIa III II Im ESESRRSSRRSR Ii I ~I I RS WRSggR WWLRLC I

a 5 ~

~iIIIiIL'IIlllih INN g)l 5 aa kk k

II I.hh;. ,I mhhp%$

I /p mr~ I Il

~

~ I'o ~ ~ ~

~ I~ 'o I ~

~ ~ ~

SgO S 8 ES8 Igg p$ pgg g 51 m~l5 RWKWKHWHR gIC gS rr SS Ill gal%

aiba apl gR g RRI g g gggg aaSQ 0 o ~ ~ ~ ~ o III 8 R SSR Q %8 Ilg ~ 55 S SOS aS S8 R SO SOS gag ~ EW

$ 15 ~8 gE gSE SE LR IWg Ep g

I al8 aaa y

4 IR ha t al g

~

HhHa f

~

~ ~ ~

8

~ ~

~

k kk kk kkk ~

g'%g ~ kk ~ k k kk laa laal II ~ I kkk Qaa kkk kh>

Ila a kW k 5

~ al k 55M

~ ~

II IL ARR III kkk kkk kk k 5 aaaI IL lla aa kkkk la I aa IaaaII laI 'Iaa lllahmla Iaal ll L

I ~ 'i I I haa<III I OS I

kI

~

I ~ ~ ~

k Ik Ik

ak SSS S ~ R S S S a a ilk SQS SS S S SS SS c

ak Slays/

l'l

~ I ~

SSS SSS

~ ak kaa Illa kkk a~

S a:i ala 'a ASS

~ kk

~ kk Lkgk kkk ak

~ ak ASS Si Ilk kl

~ kk SSS SSS XSS ASS SSAII

~ ll SSS SSh Q g S lla F. ~ kl SSS SS SS ISSS

~

a

~ ka SS SSS SOS SS SS SSS

~ ka I i(k 'a kkk SS

~

SSS

~

SSS

~ ~ ~ I ha a Iak lll SSS

~

RES 5IINIIHI ~ kl SSS S SS SSS akk SSS SSS SS SS SSS

~ ak SSS

'aii ll ASS SSSS S SS kkkgk SSa

~ ak q kk S

SSS SWISS SSS SSS SSS SSSS SSS SSS S S I 'o

920701 4.0 Linear Heat Generation Rate (LHGR) Limit for Use in Technical Specification 3.2.4 The LHGR limit for use in Technical'Specification 3.2.4 shall not exceed the values shown in Figures 15, 16, 17, 18, and 19.

Washington Nuclear-Unit 2 COLR 92-8 Rev. 0

DIES ESgSSEgE Smg EpE 0 8 SS I Iil ill il liei~lll ii L~

I Ill Ill E IEgs gism%

REL 851i LR

)san gs I Ia Ig I~ )'.ii Ii. i.

Ill ae Psa E~1 5555555a555 sa5 NS BL p Ill CII

..I IIIiii lul hii hau B5:.

RI~ 1<ggl1 I ~ ~ I I ~ II ~ II I I

~ ~ 'I ~ ~ ~ II ~ ~

I ~ ~ ~ I~ I ~ I~ I

I'I II I I I I~ IgII gII I Ii IIIII

.I:.I:

ailllll Ill I

~ i:IIIIII III ~ I SmkSISS5

~ ~ EH$

NSNNARSm Rmh'cl RNm sk N SNmmmw 50k' Nmmsmmms Nlm PPI IIII A iiQRAm I!'!ill 5 8 I

1,.

II

~ I m m I SE Ia

~

- '- IQIRMR

"'-lil REIRmgI IRRER I

I!maim

- ll i"i" IIIIII

~

~ IIllhh50iRRIRIIII aLslaa ming>iARi

,i. I IIILIIIR LIhhlls $ IIIL Is IRRIRERI PREWRPlgRII ~

~ Ill SSaaraaaaaaaaarar WNAA NAS IIIIIIII IIILIIIR4L. SR RNNRiASS Wi NARON IIII!illiI!i'.Ill! !I!11 ii

g aaaRaEQEggaaap)EEE 5 aa OSWSR 55 NSSSN 55 RS555 55 QiiSSRSSSiSSSSNSiRSRR iiSSSR SOS SQS ASS>Iso' SSA N %RID a aa2aaiahgg 5

NSWiSN S

~ ggaagp rnsuL AS %SEAR SIQSNNOO RANNSRNS ESSSSOSS AkS S RN aa 0 QRO ass Ia awmmrraa

~

~

ISSSSASS I ~ I

~ SRSSIk%5 IQSkSSSE11%1191%

Iia

, aiiiiilalialiallliIElillilal lli.laaii aalalia. liil.ah..

~

alaiaiii liia

~ ~ ~

ill ~ ~ ~ ~

I en

~ ~ ~ ~

I iii Iiilll I

~ ~ ~ ~

ialliii II ~ ~ ~ I~

A Akk kk k A IIIimamilmmaaaIIIam

.aalm aa aeaemm kkkkkk %%%%%%&$ 5% IISIIII kkkkkkkk aCRamaas Akkkkk kkkkkkkk Akk MAX kk kkkk AWAA kkkr kAkkkkk . I; A

A kkkkkkkkkk kkkkkkkk Akkk A amIRLa kkkkkk RIRIaa kkkkkkkk kkkkkk s I ~ ~

I III WAMkkkkk Akkkkkk rkr kkkk Akk MWW k kk k Wk WWAAAAAXM kkkkkk kkkkkkkkk Akkkkk W k

akkkkkkkkk al r kkk sar Ia Akkkk aaa Akkkkkk ARAA kk I ~ ~ I

kkkSkkkkkkkkkk )kg kk k kgkkkkkk g kk

, haaKaiba aaL11 1 Rs1 11as sLassa1 1 1 s a s1sagagpgggassm saass1I sggsgsg am ~

g ILas1s

~ sgsaa1s IgssgSChsh 11 a 11 11

~ s1~

asRaRaa

~ s s sassssmLs as

~

is ~)gas s1sa a k

I1 k kkk 1

kkk k k II I~II k $i .e:Ik E

kk kkkk I

I1 iiiii'-'-.-"., ~ hh h5imi 1 l1i 1.

kkkkkkkk ~ sass kkkkk sassafras kkkkkkl~k a1al1 ask LNLS:

OOOEkkkk O kkk kk

~ sasasa ggilgip I ROSE ua1 1raaas1 NsCa asCs1L ONkkkkN kkkkkkkl. MOOOOEE O Iialggi haslLuah 1 a1aa sassa]ss ~ pa)lass

~ L1111 kk k kkk 11 kk ssLSRR aasRaaL k kk sssLCs18 kk k kkk kkkkk shah'. I

~ iii ~ ~ ~ ~ ~ iii ~ i ~ ii ~ ~ ~

92070l 5.0 References 5.1 EMF-92-039, Revision 1, WNP-2 Cycle 8 Plant Transient Analysis, Siemens Nuclear Power Corporation, June 1992.

5.2 EMF-92-040, Revision 1, WNP-2 Cycle 8 Reload Analysis, Siemens Nuclear Power Corporation, June 1992.

5.3 GE11 Lead Fuel Assembly Report for Washington Public Power Supply System Nuclear Project No. 2, Reload 5, Cycle 6, General Electric Company, December 1989 (Proprietary).

5.4 UK 90-126, Supplemental Lead Fuel Assembly Licensing Report SVE'A-96LFA's for WNP-2, ABB Atom, January 1990 (Proprietary).

5.5 ATOP-91-120, W. R. Harris, ABB, to D. L. Whitcomb, Supply System, Assembly Treatment in WNP-2 Cycle 7 Core Operating Limits Report, May 1, 1991.

5.6 SNPWP-92-0059, Udell Fresk, Siemens Nuclear Power Corporation, to R. A. Vopalensky, Supply System, Comments on WNP-2 Cycle 8 Draft COLR Report, May 21, 1992.

5.7 JTW:92-087, J. T. Worthington, General Electric Company, to D. L. Whitcomb, Supply System, WNP-2 Cycle 8 Core Operating Limits Report, Contract No.

C-21099, Gall Lead Fuel Assemblies, May 22, 1992.

5.8 ATOP-92-062, W. R. Harris, ABB Atom, to D. L. Whitcomb, Supply System, SVE'A-96 Lead Fuel Assembly Treatment in'WNP-2 Cycle 8 Core Operating Limits Report, May 15, 1992.

5.9 SNPWP-92-0072, Udell Fresk, Siemens Nuclear Power Corporation, to R. A. Vopalensky, Power Dependent MCPR Limitsfor WNP-2 Cycle 8, June 24, 1992.

5.10 ANF-89-014(P)(A), Revision 1 and Supplement 1 & 2, Generic Mechanical Design for Advanced Nuclear Fuels 9'-1X and 9x9-9X Reload Fuel, Advanced Nuclear Fuels Corporation, Richland, WA, October 1991.

5.11 XN-NF-79-71(P), Revision 2, including Supplements 1,2 and 3(A), Enon Nuclear Plant Transient Methodology for Boiling Water Reactors, Exxon Nuclear Company, Inc., Richland, WA, November 1981.

5.12 XN-NF-80-19(P)(A), Volume 1 Supplement 1 and 2, Exron Nuclear Methodology for Boiling Water Reactors Neutronic Methods for Design Analysis, March 1983.

Washington Nuclear-Unit 2 COLR 92-8 Rev. 0

5.13 i 92%01 XN-NF-80-19(P)(A), Volume 1 Supplements 3 and 4, Exxon Nuclear Methodology for Boiling Water Reactors Neutronic Methods for Design Analysis, Advanced Nuclear Fuels Corporation, Richland, WA, November 1990.

5.14 XN-NF-80-19(P)(A), Volume 3, Revision 2, Exxon Nuclear Methodology for Boiling Water Reactors THERMEK Thermal Limits Methodology Summary Description, Exxon Nuclear Company, Inc., Richland, WA, January 1987.

5.15 XN-NF-80-19(P)(A), Volume 4, Revision 1, Exxon Nuclear Methodology for Boiling Water Reactors: Application of the ENC Methodology to BWR Reloads, Exxon Nuclear Company, Inc., Richland, WA, June 1986.

5.16 ANF-913(P)(A), Volume 1, Revision 1 and Volume 1, Supplements 2, 3, and 4, COTRANSA2: A Computer Program for Boiling Water Reactor Transient Analyses, Advanced Nuclear Fuels Corporation, Richland, WA, August 1990.

5.17 ANF-524(P)(A), Revision 2 and Supplements 1 and 2, Advanced Nuclear Fuels Critical Power Methodology for Boiling Water Reactors, Advanced Nuclear Fuels Corporation, Richland, WA, November 1990.

5.18 ANF-1125(P)(A) and Supplements 1 and 2, ANFB Crirical Power Correlation, Advanced Nuclear Fuels Corporation, Richland, WA, April 1990 5.19 Letter, R. C. Jones (NRC) to R. A. Copeland (ANF), NRC Approval of ANFB Additive Constants for 5%9-5K BWR Fuel, November 14, 1990.

5.20 Letter ENWB-96-0067, J. B. Edgar (ANF) to Supply System, Supplemental Licensing Analysis Results, April 15, 1986.

5.21 ANF-90-01, WNP-2 Cycle 6 Plant Transient Analysis, Advanced Nuclear Fuels Corporation, Richland, WA, January 1990.

5.22 XN-NF-84-105(P)(A), Volume 1 and Supplements 1, 2, & 4, XCOBRA-T: A Computer Code for BWR Transient Thermal Hydraulic Core Analysis, Exxon Nuclear Company, Inc., Richland, WA, February 1987.

5.23 XN-NF-81-21(P)(A), Revision 1, Generic Mechanical Design for Exxon Nuclear Jet Pump BWR Relouf Fuel, Exxon Nuclear Company, Inc., Richland, WA, September 1982, and Supplement 1, March 1985.

5.24 XN-NF-85-67(P)(A), Revision 1, Generic Mechanical Design for Exxon Nuclear Jet Pump BWR Reload Fuel, Exxon Nuclear Company, Inc., Richland, WA, September 1986.

Washington Nuclear-Unit 2 COLR 92-8 Rev. 0

5.25 TAC M83319, Docket 50-397, Proposed Bx8 Fuel Burnup Extension for Cycle 8 WNP-2 PAC No. M83319), R. R. Assa, NRC, to G. C. Sorensen, July 1, 1992.

5.26 XN-NF-81-58(A), Revision 2, RODEX2: Fuel Rod Mechanical Response Evaluation Model, Exxon Nuclear Company, Inc., Richland, WA, March 1984.

5.27 XN-NF-87-92 and Supplement 1, WNP-2 Plant Transient Analysis With Final Feedwater Temperature Reduction, Advanced Nuclear Fuels Corporation, Richland, WA, June 1987'and May 1988.

5.28 ANF-87-119, WNP-2 Single Loop Operation Analysis, Advanced Nuclear Fuels Corporation, Richland, WA, September 1987.

5.29 ANF-87-118, WNP-2 LOCA Analysis For Single Loop Operation, Advanced Nuclear Fuels Corporation, Richland, WA, September 1987.

5.30 Letter, R. B. Samworth, USNRC, to G. C. Sorensen, Supply System, Issuance ofAmendment No. 62 to Facility Operating License No. NPF-21-WPPSS Nuclear Project 2 (TAC No. 67538), August 5, 1988.

5.31 XN-NF-85-138(P),LOCA Break Spectrum for a BWR 5, Exxon Nuclear Company, Inc., Richland, WA, December 1985.

5.32 XN-NF-85-139, WNP-2 LOCA-ECCS Analysis, MAPLHGR Results, Exxon Nuclear Company, Inc., Richland, WA, December 1984.

5.33 ANF-CC-33(P)(A), Supplement 2, HLXY: A Generalized Multirod Heatup Code with 10 CFR SOAppendix ZHeatup Option, Advanced Nuclear Fuels Corporation, Richland, WA, January 1991.

5.34 XN-NF-81-22(P)(A), Generic Statistical Uncertainty Analysis Methodology, November 1983.

5.35 NEDE-24011-P-A-6, General Elecmc Standard Application for Reactor Fuel, April 1983.

Washington Nuclear-Unit 2 COLR 92-8 Rev. 0