1CAN030902, Inservice Inspection Summary Report for the Twenty-First Refueling Outage (1R21): Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
 
(One intermediate revision by the same user not shown)
Line 3: Line 3:
| issue date = 03/04/2009
| issue date = 03/04/2009
| title = Inservice Inspection Summary Report for the Twenty-First Refueling Outage (1R21)
| title = Inservice Inspection Summary Report for the Twenty-First Refueling Outage (1R21)
| author name = Bice D B
| author name = Bice D
| author affiliation = Entergy Operations, Inc
| author affiliation = Entergy Operations, Inc
| addressee name =  
| addressee name =  
Line 16: Line 16:


=Text=
=Text=
{{#Wiki_filter:1CAN030902  
{{#Wiki_filter:Entergy Operations, Inc.
 
1448 S.R. 333 Russellville, AR 72802 Tel 479-858-4710 David B. Bice Acting Manager, Licensing Arkansas Nuclear One 1CAN030902 March 4, 2009 U. S. Nuclear Regulatory Commission Attn.: Document Control Desk Washington, DC 20555-0001
March 4, 2009  
 
U. S. Nuclear Regulatory Commission Attn.: Document Control Desk Washington, DC 20555-0001  


==SUBJECT:==
==SUBJECT:==
Inservice Inspection Summary Report for the Twenty-First Refueling Outage (1R21)  
Inservice Inspection Summary Report for the Twenty-First Refueling Outage (1R21)
 
Arkansas Nuclear One, Unit 1 Docket No. 50-313 License No. DPR-51
Arkansas Nuclear One, Unit 1  
 
Docket No. 50-313 License No. DPR-51  


==Dear Sir or Madam:==
==Dear Sir or Madam:==


Article IWA-6000 of Section XI of the 2001 Edition with the 2003 Addenda of the ASME Code requires an inservice inspection (ISI) report be submitted to regulatory and enforcement authorities having jurisdiction at the plant site. The summary report is to contain the completed Form NIS-1, "Owner's Report for Inservice Inspection," and Form NIS-2, "Owner's Report for Repair or Replacement.
Article IWA-6000 of Section XI of the 2001 Edition with the 2003 Addenda of the ASME Code requires an inservice inspection (ISI) report be submitted to regulatory and enforcement authorities having jurisdiction at the plant site. The summary report is to contain the completed Form NIS-1, Owners Report for Inservice Inspection, and Form NIS-2, Owners Report for Repair or Replacement.
 
Regulatory Guide 1.147, Inservice Inspection Code Case Acceptability, ASME Section XI, Division 1, Revision 15 lists Code Case N-532-4 Alternative Requirements to Repair and Replacement Documentation Requirements and Inservice Summary Report Preparation and Submission as Required by IWA-4000 and IWA-6000, as a code case that is acceptable to the NRC for implementation in the ISI of light water reactors. Code Case N-532-4 has been incorporated into the ANO-1 ISI plan. This code case allows Entergy to prepare an Owners Activity Report Form OAR-1 in place of the code required NIS-1 and NIS-2 forms.
Regulatory Guide 1.147, "Inservice Inspection Code Case Acceptability, ASME Section XI, Division 1," Revision 15 lists Code Case N-532-4 "Alternative Requirements to Repair and Replacement Documentation Requirements and Inservice Summary Report Preparation and Submission as Required by IWA-4000 and IWA-6000," as a code case that is acceptable to the NRC for implementation in the ISI of light water reactors. Code Case N-532-4 has been incorporated into the ANO-1 ISI plan. This code case allows Entergy to prepare an Owner's Activity Report Form OAR-1 in place of the code required NIS-1 and NIS-2 forms.
This report is to be prepared at the completion of a refueling outage and submitted within 90 calendar days of the completion of the refueling outage.
This report is to be prepared at the completion of a refueling outage and submitted within 90 calendar days of the completion of the refueling outage.  
Attached is the completed Form OAR-1 for Arkansas Nuclear One, Unit 1 (ANO-1) for information. Included with the form are tables listing the Items with Flaws or Relevant Conditions that Required Evaluation for Continued Service and Abstract of Repairs Replacements or Corrective Measures Activities Required for Continued Service in accordance with Code Case N-532-4. The results contained in this completed form are for the twenty-first refueling outage for ANO-1 (1R21). This outage was completed on December 15, 2008.
 
This letter contains no new commitments.
Attached is the completed Form OAR-1 for Arkansas Nuclear One, Unit 1 (ANO-1) for information. Included with the form are tables listing the "Items with Flaws or Relevant Conditions that Required Evaluation for Continued Service" and "Abstract of Repairs Replacements or Corrective Measures Activities Required for Continued Service" in accordance with Code Case N-532-4. The results contained in this completed form are for the twenty-first refueling outage for ANO-1 (1R21). This outage was completed on December 15, 2008.
This letter contains no new commitments. Entergy Operations, Inc. 1448 S.R. 333 Russellville, AR  72802 Tel  479-858-4710 David B. Bice Acting Manager, Licensing Arkansas Nuclear One
 
1CAN030902 Page 2 of 2
 
By means of this submittal, the reporting requirements of IWA-6000 are fulfilled for 1R21.
 
If you have any questions or require additional information, please contact me.
 
Sincerely, 


DBB/rwc
1CAN030902 Page 2 of 2 By means of this submittal, the reporting requirements of IWA-6000 are fulfilled for 1R21.
If you have any questions or require additional information, please contact me.
Sincerely, DBB/rwc


==Attachment:==
==Attachment:==
Form OAR-1, Owner's Activity Report  
Form OAR-1, Owners Activity Report cc:     Mr. Elmo E. Collins Regional Administrator U. S. Nuclear Regulatory Commission Region IV 612 E. Lamar Blvd., Suite 400 Arlington, TX 76011-4125 NRC Senior Resident Inspector Arkansas Nuclear One P. O. Box 310 London, AR 72847 U. S. Nuclear Regulatory Commission Attn: Mr. Alan B. Wang MS O-7 D1 Washington, DC 20555-0001 Mr. Bernard R. Bevill Arkansas Department of Health Radiation Control Section 4815 West Markham Street Slot #30 Little Rock, AR 72205
 
cc: Mr. Elmo E. Collins Regional Administrator U. S. Nuclear Regulatory Commission Region IV 612 E. Lamar Blvd., Suite 400 Arlington, TX 76011-4125  
 
NRC Senior Resident Inspector Arkansas Nuclear One P. O. Box 310 London, AR 72847  
 
U. S. Nuclear Regulatory Commission Attn: Mr. Alan B. Wang MS O-7 D1 Washington, DC 20555-0001 Mr. Bernard R. Bevill  
 
Arkansas Department of Health Radiation Control Section 4815 West Markham Street Slot #30 Little Rock, AR 72205
 
ATTACHMENT TO 1CAN030902 FORM OAR-1  OWNER'S ACTIVITY REPORT
 
Attachment to 1CAN030902
 
Page 1 of 7 FORM OAR-1 OWNER'S ACTIVITY REPORT
 
Report Number  OAR-1411
 
Plant  Arkansas Nuclear One / 1448 S.R. 333, Russellville, AR. 72802
 
Unit No. 1  Commercial service date  December 19, 1974  Refueling outage no. 1R21 (If applicable)
 
Current inspection interval  Fourth (4th) Inspection Interval (1st, 2nd, 3rd, 4th, other)
 
Current inspection period  First (1st) Inspection Period (1st, 2nd, 3rd)
 
Edition and Addenda of Section XI applicable to the inspection plan 2001 Edition with 2003 Addenda
 
Date and revision of inspection plan May 27, 2008 / Revision 0
 
Edition and Addenda of Section XI applicable to repairs and replacements, if different than the inspection plan Same
 
Code Cases used: N-532-4 (if applicable)
 
CERTIFICATE OF CONFORMANCE I certify that (a)  the statements made in this report are correct; (b) the examinations, tests meet the Inspection Plan as required by the ASME Code, Section XI; and (c) the repair/replacement activities and evaluations supporting  the completion of    1R21    conform to the requirements of Section XI. (refueling outage number)
 
Signed Original signed by Richard E. Holman, Technical Specialist IV      Date  02/16/2009________
Owner or Owner's Designee, Title


CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of  Arkansas  and employed by  HSBCT  of    Hartford, Connecticut  have inspected the items  described in this Owner's Activity Report, and state that to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair/replacement activities and evaluation described in this report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
ATTACHMENT TO 1CAN030902 FORM OAR-1 OWNERS ACTIVITY REPORT
Commissions  NB-9985, ARK-1054 "A" "B" "N" "I" "NS"  Inspector's Signature  National Board, State, Province, and Endorsements Date 02/17/2009


Attachment to 1CAN030902  
Attachment to 1CAN030902 Page 1 of 7 FORM O AR-1 OWNER'S ACTIVITY REPORT Report Number          OAR-1411 Plant      Arkansas Nuclear One / 1448 S.R. 333, Russellville, AR. 72802 Unit No.        1                Commercial service date        December 19, 1974                        Refueling outage no.      1R21 (If applicable)
Current inspection interval    Fourth (4th) Inspection Interval (1st, 2nd, 3rd, 4th, other)
Current inspection period      First (1st) Inspection Period (1st, 2nd, 3rd)
Edition and Addenda of Section XI applicable to the inspection plan          2001 Edition with 2003 Addenda Date and revision of inspection plan        May 27, 2008 / Revision 0 Edition and Addenda of Section XI applicable to repairs and replacements, if different than the inspection plan      Same Code Cases used: N-532-4 (if applicable)
CERTIFICATE OF CONFORMANCE I certify that (a) the statements made in this report are correct; (b) the examinations, tests meet the Inspection Plan as required by the ASME Code, Section XI; and (c) the repair/replacement activities and evaluations supporting the completion of                          1R21                                  conform to the requirements of Section XI.
(refueling outage number)
Signed      Original signed by Richard E. Holman, Technical Specialist IV                          Date 02/16/2009________
Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of      Arkansas                            and employed by HSBCT                                        of Hartford, Connecticut                                                                              have inspected the items described in this Owner's Activity Report, and state that to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair/replacement activities and evaluation described in this report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Original signed by Carl Thompson                  Commissions        NB-9985, ARK-1054 "A" "B" "N" "I" "NS" Inspector's Signature                                      National Board, State, Province, and Endorsements Date    02/17/2009


Page 2 of 7 TABLE 1 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE 1R21 Examination Category and Item Number Item Description Evaluation Description B-D B3.90 Nozzle to Reactor Vessel Weld (ISI # 01-018) Indication exceeded IWB-3500 (CR-ANO-1-2008-2190)
Attachment to 1CAN030902 Page 2 of 7 TABLE 1 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE 1R21 Examination Category               Item Description                     Evaluation Description and Item Number B-D               Nozzle to Reactor Vessel Weld           Indication exceeded IWB-3500 B3.90                      (ISI # 01-018)                       (CR-ANO-1-2008-2190)
R-A R1.11 Safe-end to Nozzle Dissimilar Metal Weld (ISI # 21-064)
R-A         Safe-end to Nozzle Dissimilar Metal Weld           Surface Indications R1.11                      (ISI # 21-064)                       (CR-ANO-1-2008-1959)
Surface Indications (CR-ANO-1-2008-1959)
F-A                     Support MU-161                   Support Configuration Deficiencies F1.10B                      (ISI # 23-087)                       (CR-ANO-1-2008-1913)
F-A F1.10B Support MU-161 (ISI # 23-087) Support Configuration Deficiencies (CR-ANO-1-2008-1913)
F-A                     Support MU-169                   Support Configuration Deficiencies F1.10B                      (ISI # 23-094)                       (CR-ANO-1-2008-2002)
F-A F1.10B Support MU-169 (ISI # 23-094) Support Configuration Deficiencies (CR-ANO-1-2008-2002)
C-H                       Valve SF-42                         Bonnet / Body Leakage C7.10                    (ISI # A1.PT.5.20)           (CR-ANO-1-2008-1567 and BAE-08-1-0863)
C-H C7.10 Valve SF-42 (ISI # A1.PT.5.20)
Bonnet / Body Leakage (CR-ANO-1-2008-1567 and BAE-08-1-0863)
Attachment to Unit 1 Interval 4 Period 1 1CAN030902 (for Cycle 21)  


Page 3 of 7 TABLE 2 ABSTRACT OF REPAIRS, REPLACEMENTS OR CORRECTIVE ME ASURES REQUIRED FOR CONTIN UED SERVICE (see note 1)
Attachment to                            Unit 1    Interval 4    Period 1 1CAN030902                                          (for Cycle 21)
CODE CLASS REPAIR, REPLACEMENT OR CORRECTIVE MEASURE ITEM DESCRIPTION DESCRIPTION OF WORK FLAW OR RELEVANT CONDITION FOUND DURING SCHEDULED SECTION XI EXAMINATION OR TEST (YES/NO) DATE COMPLETEDREPAIR / REPLACEMENT PLAN NUMBER AND MAI OR WO NUMBER 2 Replacement Valve Normal rotation for MS valve PSV-2689 No 12/10/2008 Plan # 06-2106, WO 00084135 2 Replacement Valve Normal rotation for MS valve PSV-2691 No 12/10/2008 Plan # 06-2107, WO 00084133 2 Replacement Valve Normal rotation for MS valve PSV-2693 No 12/10/2008 Plan # 06-2108, WO 00084132 2 Replacement Valve Normal rotation for MS valve PSV-2694 No 12/10/2008 Plan # 06-2109, WO 00084131 2 Replacement Valve Normal rotation for MS valve PSV-2695 No 12/10/2008 Plan # 06-2110, WO 00084130 Attachment to Unit 1 Interval 4 Period 1 1CAN030902 (for Cycle 21)
Page 3 of 7 TABLE 2 ABSTRACT OF REPAIRS, REPLACEMENTS OR CORRECTIVE MEASURES REQUIRED FOR CONTINUED SERVICE (see note 1)
CODE         REPAIR,     ITEM     DESCRIPTION OF WORK                 FLAW OR     DATE        REPAIR /
CLASS    REPLACEMENT  DESCRIPTION                                    RELEVANT COMPLETED  REPLACEMENT OR                                                    CONDITION             PLAN NUMBER CORRECTIVE                                              FOUND DURING             AND MAI OR WO MEASURE                                                  SCHEDULED                 NUMBER SECTION XI EXAMINATION OR TEST (YES/NO) 2       Replacement   Valve   Normal rotation for MS valve           No     12/10/2008 Plan # 06-2106, PSV-2689                                          WO 00084135 2       Replacement   Valve   Normal rotation for MS valve           No     12/10/2008 Plan # 06-2107, PSV-2691                                          WO 00084133 2       Replacement   Valve   Normal rotation for MS valve           No     12/10/2008 Plan # 06-2108, PSV-2693                                          WO 00084132 2       Replacement   Valve   Normal rotation for MS valve           No     12/10/2008 Plan # 06-2109, PSV-2694                                          WO 00084131 2       Replacement   Valve   Normal rotation for MS valve           No     12/10/2008 Plan # 06-2110, PSV-2695                                          WO 00084130


Page 4 of 7 TABLE 2 CODE CLASS REPAIR, REPLACEMENT OR CORRECTIVE MEASURE ITEM DESCRIPTION DESCRIPTION OF WORK FLAW OR RELEVANT CONDITION FOUND DURING SCHEDULED SECTION XI EXAMINATION OR TEST (YES/NO) DATE COMPLETEDREPAIR / REPLACEMENT PLAN NUMBER AND MAI OR WO NUMBER 2 Replacement Valve Normal rotation for MS valve PSV-2697 No 12/10/2008 Plan # 06-2111, WO 00084129 2 Replacement Valve Replace valve disc for CV 1406 No 11/30/2008 Plan # 07-2000, WO 00079266 T3 Replacement Valve Replace valve disc for CV 1616 No 12/04/2008 Plan # 07-2003, WO 00065583 T3 Replacement Cooler Replaced Cooling Coil VUC 7C Invoked CC N-416-2 No 10/11/2007 Plan # 07-2060, WO 50033103 T2 Replacement Piping Modify HCD-3-4 & 8 Piping No 12/04/2008 Plan # 08-2035, WO 00050292 T2 Replacement Support Modify support DH-80 No 12/02/2008 Plan # 08-2036, WO 00050292 T2 Replacement Support Modify support DH-413 No 12/04/2008 Plan # 08-2037, WO 00050292 Attachment to Unit 1 Interval 4 Period 1 1CAN030902 (for Cycle 21)
Attachment to                            Unit 1    Interval 4    Period 1 1CAN030902                                          (for Cycle 21)
Page 4 of 7 TABLE 2 CODE         REPAIR,     ITEM     DESCRIPTION OF WORK                 FLAW OR     DATE        REPAIR /
CLASS    REPLACEMENT  DESCRIPTION                                    RELEVANT COMPLETED  REPLACEMENT OR                                                    CONDITION             PLAN NUMBER CORRECTIVE                                              FOUND DURING             AND MAI OR WO MEASURE                                                  SCHEDULED                 NUMBER SECTION XI EXAMINATION OR TEST (YES/NO) 2       Replacement   Valve   Normal rotation for MS valve           No     12/10/2008 Plan # 06-2111, PSV-2697                                          WO 00084129 2       Replacement   Valve       Replace valve disc for               No     11/30/2008 Plan # 07-2000, CV 1406                                          WO 00079266 T3       Replacement   Valve       Replace valve disc for               No     12/04/2008 Plan # 07-2003, CV 1616                                          WO 00065583 Replaced Cooling Coil T3       Replacement   Cooler                                           No     10/11/2007 Plan # 07-2060, VUC 7C Invoked CC N-416-2 WO 50033103 T2       Replacement   Piping   Modify HCD-3-4 & 8 Piping             No     12/04/2008 Plan # 08-2035, WO 00050292 T2       Replacement   Support     Modify support DH-80                 No     12/02/2008 Plan # 08-2036, WO 00050292 T2       Replacement   Support     Modify support DH-413                 No     12/04/2008 Plan # 08-2037, WO 00050292


Page 5 of 7 TABLE 2 CODE CLASS REPAIR, REPLACEMENT OR CORRECTIVE MEASURE ITEM DESCRIPTION DESCRIPTION OF WORK FLAW OR RELEVANT CONDITION FOUND DURING SCHEDULED SECTION XI EXAMINATION OR TEST (YES/NO) DATE COMPLETEDREPAIR / REPLACEMENT PLAN NUMBER AND MAI OR WO NUMBER T2 Replacement Support Modify support DH-411 No 12/02/2008 Plan # 08-2038, WO 00050292 2 Replacement Piping Modify HCB-6-4 Piping No 12/04/2008 Plan # 08-2039, WO 00050292 2 Replacement Valve Replaced valve disc on CV 1278 No 12/11/2008 Plan # 08-2049, WO 00104249 3 Replacement Valve Replaced valve disc on CV 1250 No 11/07/2008 Plan # 08-2077, WO 00163263 1 Replacement Piping Core Flood weld 01-025 Onlay and CCA-6-14 Piping No 12/10/2008 Plan # 08-2079, WO 00124774 1 Replacement Piping Core Flood weld 01-026 Onlay and CCA-6-14 Piping No 12/10/2008 Plan # 08-2080, WO 00124774 1 Replacement Support Modified support DH-164 No 12/03/2008 Plan # 08-2081, WO 00124774 Attachment to Unit 1 Interval 4 Period 1 1CAN030902 (for Cycle 21)
Attachment to                              Unit 1  Interval 4    Period 1 1CAN030902                                          (for Cycle 21)
Page 5 of 7 TABLE 2 CODE         REPAIR,     ITEM     DESCRIPTION OF WORK                 FLAW OR     DATE        REPAIR /
CLASS    REPLACEMENT  DESCRIPTION                                    RELEVANT COMPLETED  REPLACEMENT OR                                                    CONDITION             PLAN NUMBER CORRECTIVE                                              FOUND DURING             AND MAI OR WO MEASURE                                                  SCHEDULED                 NUMBER SECTION XI EXAMINATION OR TEST (YES/NO)
T2       Replacement   Support     Modify support DH-411               No     12/02/2008 Plan # 08-2038, WO 00050292 2       Replacement   Piping     Modify HCB-6-4 Piping               No     12/04/2008 Plan # 08-2039, WO 00050292 2       Replacement   Valve       Replaced valve disc on               No     12/11/2008 Plan # 08-2049, CV 1278                                          WO 00104249 3       Replacement   Valve       Replaced valve disc on               No     11/07/2008 Plan # 08-2077, CV 1250                                          WO 00163263 1       Replacement   Piping   Core Flood weld 01-025 Onlay           No     12/10/2008 Plan # 08-2079, and CCA-6-14 Piping                                    WO 00124774 1       Replacement   Piping   Core Flood weld 01-026 Onlay           No     12/10/2008 Plan # 08-2080, and CCA-6-14 Piping                                    WO 00124774 1       Replacement   Support     Modified support DH-164               No     12/03/2008 Plan # 08-2081, WO 00124774


Page 6 of 7 TABLE 2 CODE CLASS REPAIR, REPLACEMENT OR CORRECTIVE MEASURE ITEM DESCRIPTION DESCRIPTION OF WORK FLAW OR RELEVANT CONDITION FOUND DURING SCHEDULED SECTION XI EXAMINATION OR TEST (YES/NO) DATE COMPLETEDREPAIR / REPLACEMENT PLAN NUMBER AND MAI OR WO NUMBER 1 Replacement Support Modified support DH-196 No 12/01/2008 Plan # 08-2082, WO 00124774 1 Replacement Valve Replaced valve disc for SV 1073 No 12/09/2008 Plan # 08-2085, WO 00111854 1 Repair Piping Structural weld overlay CCA 12 Piping No 12/10/2008 Plan # 08-2088, WO 00124770 2 Replacement Valve Replaced valve bonnet for MU-20A No 12/09/2008 Plan # 08-2091, WO 00104247 2 Replacement Heat ExchangerReplaced secondary manway cover fasteners for E-24A No 11/09/2008 Plan # 08-2093, WO 00130799 2 Replacement Support Modify Support MU-201H-H2 No 11/21/2008 Plan # 08-2096, WO 00170974 2 Replacement Piping Modify GCB-3-3 & 8 Piping No 12/06/2008 Plan # 08-2098, WO 00170929 Attachment to Unit 1 Interval 4 Period 1 1CAN030902 (for Cycle 21)
Attachment to                                  Unit 1    Interval 4  Period 1 1CAN030902                                              (for Cycle 21)
Page 6 of 7 TABLE 2 CODE         REPAIR,       ITEM       DESCRIPTION OF WORK                 FLAW OR     DATE        REPAIR /
CLASS    REPLACEMENT  DESCRIPTION                                        RELEVANT COMPLETED  REPLACEMENT OR                                                        CONDITION             PLAN NUMBER CORRECTIVE                                                  FOUND DURING             AND MAI OR WO MEASURE                                                      SCHEDULED                 NUMBER SECTION XI EXAMINATION OR TEST (YES/NO) 1       Replacement   Support       Modified support DH-196               No     12/01/2008 Plan # 08-2082, WO 00124774 1       Replacement     Valve         Replaced valve disc for             No     12/09/2008 Plan # 08-2085, SV 1073                                        WO 00111854 1         Repair       Piping     Structural weld overlay CCA           No     12/10/2008 Plan # 08-2088, 12 Piping                                      WO 00124770 2       Replacement     Valve       Replaced valve bonnet for             No     12/09/2008 Plan # 08-2091, MU-20A                                          WO 00104247 2       Replacement Heat Exchanger Replaced secondary manway               No     11/09/2008 Plan # 08-2093, cover fasteners for E-24A                                WO 00130799 2       Replacement   Support     Modify Support MU-201H-H2               No     11/21/2008 Plan # 08-2096, WO 00170974 2       Replacement     Piping     Modify GCB-3-3 & 8 Piping             No     12/06/2008 Plan # 08-2098, WO 00170929


Page 7 of 7 TABLE 2 CODE CLASS REPAIR, REPLACEMENT OR CORRECTIVE MEASURE ITEM DESCRIPTION DESCRIPTION OF WORK FLAW OR RELEVANT CONDITION FOUND DURING SCHEDULED SECTION XI EXAMINATION OR TEST (YES/NO) DATE COMPLETEDREPAIR / REPLACEMENT PLAN NUMBER AND MAI OR WO NUMBER 1 Replacement Support Replace Support DH-197 piping U-bolt No 12/01/2008 Plan # 08-2102, WO 00124774 1 Repair Piping Non-welded repair to CCA-6-14" Piping for Carbon Steel splatter removal No 11/27/2008 Plan # 08-2103, WO 00124774 1 Replacement Heat ExchangerReplaced primary handhole cover fasteners for E-24B No 12/07/2009 Plan # 08-2104, WO 00161862 Note 1: Table 2 is an abstract of all Repair/Replacement activities performed during Cycle 21 to comply with site procedural requirements.}}
Attachment to                                            Unit 1    Interval 4    Period 1 1CAN030902                                                        (for Cycle 21)
Page 7 of 7 TABLE 2 CODE         REPAIR,               ITEM         DESCRIPTION OF WORK                 FLAW OR           DATE            REPAIR /
CLASS    REPLACEMENT        DESCRIPTION                                              RELEVANT     COMPLETED          REPLACEMENT OR                                                                  CONDITION                         PLAN NUMBER CORRECTIVE                                                              FOUND DURING                       AND MAI OR WO MEASURE                                                                  SCHEDULED                           NUMBER SECTION XI EXAMINATION OR TEST (YES/NO) 1       Replacement           Support         Replace Support DH-197                 No         12/01/2008       Plan # 08-2102, piping U-bolt                                                WO 00124774 1         Repair               Piping       Non-welded repair to CCA             No         11/27/2008       Plan # 08-2103, 14 Piping for Carbon Steel                                          WO 00124774 splatter removal 1       Replacement       Heat Exchanger      Replaced primary handhole               No         12/07/2009       Plan # 08-2104, cover fasteners for E-24B                                            WO 00161862 Note 1: Table 2 is an abstract of all Repair/Replacement activities performed during Cycle 21 to comply with site procedural requirements.}}

Latest revision as of 09:30, 14 November 2019

Inservice Inspection Summary Report for the Twenty-First Refueling Outage (1R21)
ML090630644
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 03/04/2009
From: David Bice
Entergy Operations
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
1CAN030902
Download: ML090630644 (10)


Text

Entergy Operations, Inc.

1448 S.R. 333 Russellville, AR 72802 Tel 479-858-4710 David B. Bice Acting Manager, Licensing Arkansas Nuclear One 1CAN030902 March 4, 2009 U. S. Nuclear Regulatory Commission Attn.: Document Control Desk Washington, DC 20555-0001

SUBJECT:

Inservice Inspection Summary Report for the Twenty-First Refueling Outage (1R21)

Arkansas Nuclear One, Unit 1 Docket No. 50-313 License No. DPR-51

Dear Sir or Madam:

Article IWA-6000 of Section XI of the 2001 Edition with the 2003 Addenda of the ASME Code requires an inservice inspection (ISI) report be submitted to regulatory and enforcement authorities having jurisdiction at the plant site. The summary report is to contain the completed Form NIS-1, Owners Report for Inservice Inspection, and Form NIS-2, Owners Report for Repair or Replacement.

Regulatory Guide 1.147, Inservice Inspection Code Case Acceptability, ASME Section XI, Division 1, Revision 15 lists Code Case N-532-4 Alternative Requirements to Repair and Replacement Documentation Requirements and Inservice Summary Report Preparation and Submission as Required by IWA-4000 and IWA-6000, as a code case that is acceptable to the NRC for implementation in the ISI of light water reactors. Code Case N-532-4 has been incorporated into the ANO-1 ISI plan. This code case allows Entergy to prepare an Owners Activity Report Form OAR-1 in place of the code required NIS-1 and NIS-2 forms.

This report is to be prepared at the completion of a refueling outage and submitted within 90 calendar days of the completion of the refueling outage.

Attached is the completed Form OAR-1 for Arkansas Nuclear One, Unit 1 (ANO-1) for information. Included with the form are tables listing the Items with Flaws or Relevant Conditions that Required Evaluation for Continued Service and Abstract of Repairs Replacements or Corrective Measures Activities Required for Continued Service in accordance with Code Case N-532-4. The results contained in this completed form are for the twenty-first refueling outage for ANO-1 (1R21). This outage was completed on December 15, 2008.

This letter contains no new commitments.

1CAN030902 Page 2 of 2 By means of this submittal, the reporting requirements of IWA-6000 are fulfilled for 1R21.

If you have any questions or require additional information, please contact me.

Sincerely, DBB/rwc

Attachment:

Form OAR-1, Owners Activity Report cc: Mr. Elmo E. Collins Regional Administrator U. S. Nuclear Regulatory Commission Region IV 612 E. Lamar Blvd., Suite 400 Arlington, TX 76011-4125 NRC Senior Resident Inspector Arkansas Nuclear One P. O. Box 310 London, AR 72847 U. S. Nuclear Regulatory Commission Attn: Mr. Alan B. Wang MS O-7 D1 Washington, DC 20555-0001 Mr. Bernard R. Bevill Arkansas Department of Health Radiation Control Section 4815 West Markham Street Slot #30 Little Rock, AR 72205

ATTACHMENT TO 1CAN030902 FORM OAR-1 OWNERS ACTIVITY REPORT

Attachment to 1CAN030902 Page 1 of 7 FORM O AR-1 OWNER'S ACTIVITY REPORT Report Number OAR-1411 Plant Arkansas Nuclear One / 1448 S.R. 333, Russellville, AR. 72802 Unit No. 1 Commercial service date December 19, 1974 Refueling outage no. 1R21 (If applicable)

Current inspection interval Fourth (4th) Inspection Interval (1st, 2nd, 3rd, 4th, other)

Current inspection period First (1st) Inspection Period (1st, 2nd, 3rd)

Edition and Addenda of Section XI applicable to the inspection plan 2001 Edition with 2003 Addenda Date and revision of inspection plan May 27, 2008 / Revision 0 Edition and Addenda of Section XI applicable to repairs and replacements, if different than the inspection plan Same Code Cases used: N-532-4 (if applicable)

CERTIFICATE OF CONFORMANCE I certify that (a) the statements made in this report are correct; (b) the examinations, tests meet the Inspection Plan as required by the ASME Code,Section XI; and (c) the repair/replacement activities and evaluations supporting the completion of 1R21 conform to the requirements of Section XI.

(refueling outage number)

Signed Original signed by Richard E. Holman, Technical Specialist IV Date 02/16/2009________

Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Arkansas and employed by HSBCT of Hartford, Connecticut have inspected the items described in this Owner's Activity Report, and state that to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair/replacement activities and evaluation described in this report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Original signed by Carl Thompson Commissions NB-9985, ARK-1054 "A" "B" "N" "I" "NS" Inspector's Signature National Board, State, Province, and Endorsements Date 02/17/2009

Attachment to 1CAN030902 Page 2 of 7 TABLE 1 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE 1R21 Examination Category Item Description Evaluation Description and Item Number B-D Nozzle to Reactor Vessel Weld Indication exceeded IWB-3500 B3.90 (ISI # 01-018) (CR-ANO-1-2008-2190)

R-A Safe-end to Nozzle Dissimilar Metal Weld Surface Indications R1.11 (ISI # 21-064) (CR-ANO-1-2008-1959)

F-A Support MU-161 Support Configuration Deficiencies F1.10B (ISI # 23-087) (CR-ANO-1-2008-1913)

F-A Support MU-169 Support Configuration Deficiencies F1.10B (ISI # 23-094) (CR-ANO-1-2008-2002)

C-H Valve SF-42 Bonnet / Body Leakage C7.10 (ISI # A1.PT.5.20) (CR-ANO-1-2008-1567 and BAE-08-1-0863)

Attachment to Unit 1 Interval 4 Period 1 1CAN030902 (for Cycle 21)

Page 3 of 7 TABLE 2 ABSTRACT OF REPAIRS, REPLACEMENTS OR CORRECTIVE MEASURES REQUIRED FOR CONTINUED SERVICE (see note 1)

CODE REPAIR, ITEM DESCRIPTION OF WORK FLAW OR DATE REPAIR /

CLASS REPLACEMENT DESCRIPTION RELEVANT COMPLETED REPLACEMENT OR CONDITION PLAN NUMBER CORRECTIVE FOUND DURING AND MAI OR WO MEASURE SCHEDULED NUMBER SECTION XI EXAMINATION OR TEST (YES/NO) 2 Replacement Valve Normal rotation for MS valve No 12/10/2008 Plan # 06-2106, PSV-2689 WO 00084135 2 Replacement Valve Normal rotation for MS valve No 12/10/2008 Plan # 06-2107, PSV-2691 WO 00084133 2 Replacement Valve Normal rotation for MS valve No 12/10/2008 Plan # 06-2108, PSV-2693 WO 00084132 2 Replacement Valve Normal rotation for MS valve No 12/10/2008 Plan # 06-2109, PSV-2694 WO 00084131 2 Replacement Valve Normal rotation for MS valve No 12/10/2008 Plan # 06-2110, PSV-2695 WO 00084130

Attachment to Unit 1 Interval 4 Period 1 1CAN030902 (for Cycle 21)

Page 4 of 7 TABLE 2 CODE REPAIR, ITEM DESCRIPTION OF WORK FLAW OR DATE REPAIR /

CLASS REPLACEMENT DESCRIPTION RELEVANT COMPLETED REPLACEMENT OR CONDITION PLAN NUMBER CORRECTIVE FOUND DURING AND MAI OR WO MEASURE SCHEDULED NUMBER SECTION XI EXAMINATION OR TEST (YES/NO) 2 Replacement Valve Normal rotation for MS valve No 12/10/2008 Plan # 06-2111, PSV-2697 WO 00084129 2 Replacement Valve Replace valve disc for No 11/30/2008 Plan # 07-2000, CV 1406 WO 00079266 T3 Replacement Valve Replace valve disc for No 12/04/2008 Plan # 07-2003, CV 1616 WO 00065583 Replaced Cooling Coil T3 Replacement Cooler No 10/11/2007 Plan # 07-2060, VUC 7C Invoked CC N-416-2 WO 50033103 T2 Replacement Piping Modify HCD-3-4 & 8 Piping No 12/04/2008 Plan # 08-2035, WO 00050292 T2 Replacement Support Modify support DH-80 No 12/02/2008 Plan # 08-2036, WO 00050292 T2 Replacement Support Modify support DH-413 No 12/04/2008 Plan # 08-2037, WO 00050292

Attachment to Unit 1 Interval 4 Period 1 1CAN030902 (for Cycle 21)

Page 5 of 7 TABLE 2 CODE REPAIR, ITEM DESCRIPTION OF WORK FLAW OR DATE REPAIR /

CLASS REPLACEMENT DESCRIPTION RELEVANT COMPLETED REPLACEMENT OR CONDITION PLAN NUMBER CORRECTIVE FOUND DURING AND MAI OR WO MEASURE SCHEDULED NUMBER SECTION XI EXAMINATION OR TEST (YES/NO)

T2 Replacement Support Modify support DH-411 No 12/02/2008 Plan # 08-2038, WO 00050292 2 Replacement Piping Modify HCB-6-4 Piping No 12/04/2008 Plan # 08-2039, WO 00050292 2 Replacement Valve Replaced valve disc on No 12/11/2008 Plan # 08-2049, CV 1278 WO 00104249 3 Replacement Valve Replaced valve disc on No 11/07/2008 Plan # 08-2077, CV 1250 WO 00163263 1 Replacement Piping Core Flood weld 01-025 Onlay No 12/10/2008 Plan # 08-2079, and CCA-6-14 Piping WO 00124774 1 Replacement Piping Core Flood weld 01-026 Onlay No 12/10/2008 Plan # 08-2080, and CCA-6-14 Piping WO 00124774 1 Replacement Support Modified support DH-164 No 12/03/2008 Plan # 08-2081, WO 00124774

Attachment to Unit 1 Interval 4 Period 1 1CAN030902 (for Cycle 21)

Page 6 of 7 TABLE 2 CODE REPAIR, ITEM DESCRIPTION OF WORK FLAW OR DATE REPAIR /

CLASS REPLACEMENT DESCRIPTION RELEVANT COMPLETED REPLACEMENT OR CONDITION PLAN NUMBER CORRECTIVE FOUND DURING AND MAI OR WO MEASURE SCHEDULED NUMBER SECTION XI EXAMINATION OR TEST (YES/NO) 1 Replacement Support Modified support DH-196 No 12/01/2008 Plan # 08-2082, WO 00124774 1 Replacement Valve Replaced valve disc for No 12/09/2008 Plan # 08-2085, SV 1073 WO 00111854 1 Repair Piping Structural weld overlay CCA No 12/10/2008 Plan # 08-2088, 12 Piping WO 00124770 2 Replacement Valve Replaced valve bonnet for No 12/09/2008 Plan # 08-2091, MU-20A WO 00104247 2 Replacement Heat Exchanger Replaced secondary manway No 11/09/2008 Plan # 08-2093, cover fasteners for E-24A WO 00130799 2 Replacement Support Modify Support MU-201H-H2 No 11/21/2008 Plan # 08-2096, WO 00170974 2 Replacement Piping Modify GCB-3-3 & 8 Piping No 12/06/2008 Plan # 08-2098, WO 00170929

Attachment to Unit 1 Interval 4 Period 1 1CAN030902 (for Cycle 21)

Page 7 of 7 TABLE 2 CODE REPAIR, ITEM DESCRIPTION OF WORK FLAW OR DATE REPAIR /

CLASS REPLACEMENT DESCRIPTION RELEVANT COMPLETED REPLACEMENT OR CONDITION PLAN NUMBER CORRECTIVE FOUND DURING AND MAI OR WO MEASURE SCHEDULED NUMBER SECTION XI EXAMINATION OR TEST (YES/NO) 1 Replacement Support Replace Support DH-197 No 12/01/2008 Plan # 08-2102, piping U-bolt WO 00124774 1 Repair Piping Non-welded repair to CCA No 11/27/2008 Plan # 08-2103, 14 Piping for Carbon Steel WO 00124774 splatter removal 1 Replacement Heat Exchanger Replaced primary handhole No 12/07/2009 Plan # 08-2104, cover fasteners for E-24B WO 00161862 Note 1: Table 2 is an abstract of all Repair/Replacement activities performed during Cycle 21 to comply with site procedural requirements.