1CAN031703, Steam Generator Tube Inspection Report - 1R26

From kanterella
Jump to navigation Jump to search
Steam Generator Tube Inspection Report - 1R26
ML17081A486
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 03/22/2017
From: Pyle S
Entergy Operations
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
1CAN031703
Download: ML17081A486 (146)


Text

Entergy Operations, Inc.

1448 S.R. 333 Russellville, AR 72802 Tel 479-858-4704 Stephenie L. Pyle Manager, Regulatory Assurance Arkansas Nuclear One 1CAN031703 March 22, 2017 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555

SUBJECT:

Steam Generator Tube Inspection Report - 1R26 Arkansas Nuclear One - Unit 1 Docket No. 50-313 License No. DPR-51

Dear Sir or Madam:

Entergy Operations, Inc. (Entergy) inspected the Arkansas Nuclear One, Unit 1 (ANO-1) steam generator (SG) tubes during the Fall 2016 refueling outage (1R26) in accordance with ANO-1 Technical Specification (TS) 5.5.9, Steam Generator (SG) Program. ANO-1 TS 5.6.7 requires that the results of inspections performed during the report period be submitted to the NRC within 180 days after the initial entry into Mode 4. The initial entry into Mode 4 post-1R26 was made on December 7, 2016. Enclosed is the subject inspection report.

The 1R26 inspection performed on both SGs involved an initial full-length bobbin coil examination. The X-probe used consists of an array of coils for diagnostic testing.

This submittal completes the reporting requirements of the ANO-1 TSs for this inspection.

This letter contains no new regulatory commitments. If you have any questions concerning this submittal, please contact me.

Sincerely, ORIGINAL SIGNED BY DAVID B. BICE (ACTING REGULATORY ASSURANCE MANAGER)

FOR STEPHENIE L. PYLE SLP/rwc

Enclosure:

Results of ANO-1 SG Tube Inspections During 1R26

1CAN031703 Page 2 of 2 cc: Mr. Kriss Kennedy Regional Administrator U. S. Nuclear Regulatory Commission, Region IV 1600 East Lamar Boulevard Arlington, TX 76011-4511 NRC Senior Resident Inspector Arkansas Nuclear One P.O. Box 310 London, AR 72847 U. S. Nuclear Regulatory Commission Attn: Mr. Thomas Wengert MS O-08B1A One White Flint North 11555 Rockville Pike Rockville, MD 20852

ENCLOSURE TO 1CAN031703 RESULTS OF ANO-1 SG TUBE INSPECTIONS DURING 1R26

Enclosure to 1CAN031703 Page 1 of 9 RESULTS OF ANO-1 SG TUBE INSPECTIONS DURING 1R26 1 INTRODUCTION Arkansas Nuclear One, Unit 1 (ANO-1) Technical Specification (TS) 5.6.7, Steam Generator Tube Inspection Reports, requires Entergy Operations, Inc. (Entergy) to submit a 180-day report to the NRC that outlines the details of the steam generator (SG) tubing inspections performed during the reporting period. The report shall include:

1. The scope of inspections performed on each SG.
2. Active degradation mechanisms found.
3. Nondestructive examination (NDE) techniques utilized for each degradation mechanism.
4. Location, orientation (if linear), and measured sizes (if available) of service induced indications.
5. Number of tubes plugged during the inspection outage for each active degradation mechanism.
6. Total number and percentage of tubes plugged to date.
7. The results of condition monitoring, including the results of tube pulls and in-situ testing.

The operating period for this report includes one refueling inspection outage (1R26) in October 2016. The previous inspection (1R24) was of limited scope that included only the tubes around the tie-rods, the purpose of which was to evaluate the extent of tie-rod bowing.

The results of that inspection concluded that an additional tie-rod inspection in 1R25 would not be required. The refueling outage prior to 1R24 (1R23) included a 100% bobbin inspection and based on the results, the next full inspection would not be required until 1R26.

This report details the result of the 1R26 inspection. The inspection was a 100% full-length bobbin inspection, as well as utilizing the X-probe for diagnostic testing. Three damage mechanisms were identified, all of which have been previously identified: tie-rod bowing, tube-to-support-plate (TSP) wear, and tube-to-tube wear (TTW). No identified damage mechanism challenged the performance criteria for leakage or burst.

2 DESIGN The replacement SGs for ANO-1 are Enhanced Once-Through Steam Generators (EOTSGs) manufactured by AREVA and installed in 2005 in refueling outage 1R19. The EOTSG is a straight shell-and-tube type heat exchanger installed in a vertical position with bottom supports and emergency supports as required to accommodate normal and accident loads. The tubing consists of Inconel 690 thermally-treated tubing that is 0.625" in diameter with a 0.037" wall thickness. The tubes are expanded full depth hydraulically in the tube sheet. There are 15 TSPs that are constructed of stainless steel (SA 240 Type 410) and are a broached trefoil-hole design.

Enclosure to 1CAN031703 Page 2 of 9 3 REPORT REQUIREMENTS 3.1 Scope of Inspections Performed on Each SG The 1R26 work scope included eddy current (ECT) inspections and primary side visual inspections in each of the SGs. Bobbin examination was performed on all in-service tubes, full-length upper tube-end to lower tube-end (UTE to LTE). Array examination was performed on the periphery tubes (two deep) from the UTE to the LTE to facilitate identification of potential loose parts and elevated wear.

Table 3.1.1 1R26 Inspection Scope Examination Type # Inspections  % Scope Extent Tested SG A Bobbin 15573 100 UTE to LTE Array (periphery) 930 6 UTE to LTE SG B Bobbin 15573 100 UTE to LTE Array (periphery) 922 6 UTE to LTE 3.2 Active Degradation Mechanisms Found The 1R26 inspection was the sixth inspection following replacement of the SGs. There are three active degradation mechanisms identified: mechanical wear at tube support plate (TSP),

tube-to-tube wear (TTW), and tie-rod bowing. These are listed in Table 3.2.1.

Table 3.2.1 Total Indication List for 1R26 SG TSP Wear TTW Proximity (tie-rod bowing)

A 2001 93 64 B 1918 142 41

Enclosure to 1CAN031703 Page 3 of 9 3.3 NDE Techniques Utilized for Each Degradation Mechanism Table 3.3.1 1R26 NDE Techniques Degradation EPRI Location Inspection Technique Mechanism ETSS Bobbin Detection & Sizing broached TSPs 1-96043.1 Rev 2 Bobbin Detection Drilled TSPs 1-96042.1 Rev 4

+PointTM Detection & Sizing at Broached TSPs 96910.1 Rev 10 27901.1 Rev 1 27902.1 Rev 2 TSP Wear TSPs 27903.1 Rev 1

+PointTM Detection & Sizing at Drilled TSPs 27904.1 Rev 2 27905.1 Rev 2 27906.1 Rev 1 27907.1 Rev 2 11956.3 Rev 2 Array Detection & Sizing at Broached TSPs 11956.4 Rev 2 13091.2 Rev 0 Bobbin Detection & Sizing TTW 13091.1 Rev 0 Free-span TTW or Tube-to -tube wear Tie Rod-to-tube +PointTM Detection & Sizing TTW 13901.1 Rev 1 wear 13902.1 Rev 0 Array Detection & Sizing TTW 13902.2 Rev 0 Bobbin Detection 27091.1 Rev 2 27901.1 Rev 1 27902.1 Rev 2 27903.1 Rev 1

+PointTM Detection & Sizing 27904.1 Rev 2 27905.1 Rev 2 27906.1 Rev 1 PLP Wear PLPs & PLP Wear 27907.1 Rev 2 20400.1 Rev 5 20402.1 Rev 5 20403.1 Rev 5 Array Detection 20500.1 Rev 4 20501.1 Rev 4 20502.1 Rev 4 Tie Rod Proximity Freespan Bobbin Proximity Detection [1]

Note: ETSS Examination Technical Specification Sheet

[1] AREVA Document 51-9094580-003, Measuring the Gap between Tubes and Tie Rods with the Bobbin Coil Eddy Current Method

Enclosure to 1CAN031703 Page 4 of 9 3.4 Location, Orientation (if linear), and Measured Sizes (if available) of Service Induced Indications The service-induced mechanisms were mechanical wear at TSPs and TTW. There were no wear indications associated with proximity tubes (tubes in close contact or contacting adjacent tubes due to tie-rod bowing). Due to the large number of indications, these are listed in the following attachments:

Attachment 1 SG A TTW Attachment 2 SG B TTW Attachment 3 SG A TSP Wear Attachment 4 SG B TSP Wear 3.5 Number of Tubes Plugged During the Inspection Outage for Each Active Degradation Mechanism.

There were 32 tubes plugged in 1R26, all of which were stabilized. Listed below in Tables 3.5.1 and 3.5.2 is a summary of the plugged tubes in each SG.

Table 3.5.1 SG A Repaired Tubes in 1R26 Row Tube Repair Type Reason 10 12 Plug and Stabilize Preventative @ 10S-0.62 TSP Wear 11 13 Plug and Stabilize Preventative @ 10S-0.65 TSP Wear 13 17 Plug and Stabilize Preventative @ 10S+0.00 TSP Wear 63 8 Plug and Stabilize Preventative [1]

63 9 Plug and Stabilize Preventative [1]

64 9 Plug and Stabilize Preventative [1]

65 7 Plug and Stabilize Preventative [1]

65 9 Plug and Stabilize Preventative [1]

66 8 Plug and Stabilize Preventative [1]

66 9 Plug and Stabilize Preventative [1]

86 8 Plug and Stabilize Preventative [1]

86 9 Plug and Stabilize Preventative [1]

87 7 Plug and Stabilize Preventative [1]

87 9 Plug and Stabilize Preventative [1]

89 8 Plug and Stabilize Preventative [1]

89 9 Plug and Stabilize Preventative [1]

141 60 Plug and Stabilize Preventative @ 11S+0.39 TSP Wear 142 13 Plug and Stabilize 41% @ 10S+0.00 TSP Wear 142 51 Plug and Stabilize Preventative @ 11S+0.37 TSP Wear Note: [1] Preventatively plugged and stabilized with full-length stabilizers to cage tubes that had been stabilized with short (105) tube sheet stabilizers.

Enclosure to 1CAN031703 Page 5 of 9 Table 3.5.2 SG B Repaired Tubes in 1R26 Row Tube Repair Type Reason 6 2 Plug and Stabilize Preventative @ 11S-0.69 TSP Wear 8 10 Plug and Stabilize Preventative @ 10S-0.71 TSP Wear 8 11 Plug and Stabilize Preventative @ 10S-0.71 TSP Wear 13 15 Plug and Stabilize Preventative @ 10S-0.67 TSP Wear 13 16 Plug and Stabilize Preventative @ 10S-0.71 TSP Wear 116 1 Plug and Stabilize Preventative @ 12S-0.71 TSP Wear 117 1 Plug and Stabilize 44% @ 12S-0.71 TSP Wear 126 1 Plug and Stabilize Preventative @ 12S-0.78 TSP Wear 130 92 Plug and Stabilize Preventative @ 12S-0.62 TSP Wear 149 1 Plug and Stabilize 44% @ 12S-0.67 TSP Wear 149 4 Plug and Stabilize Preventative @ 12S-0.71 TSP Wear 149 6 Plug and Stabilize Preventative @ 12S-0.68 TSP Wear 150 5 Plug and Stabilize 42% @ 12S-0.69 TSP Wear 3.6 Total Number and Percentage of Tubes Plugged to Date.

There were no sleeves installed in either generator. The aggregate plugging information is listed in Table 3.6.1 below.

Table 3.6.1 Cumulative Plugs in Service SG A Year Outage Installed Cumulative  % Plugged 2005 Fabrication 2 (welded) 2 0.013 2005 Baseline (1R19) 0 2 0.013 2007 First ISI 1R20 0 2 0.013 2008 1R21 8 10 0.064 2010 1R22 0 10 0.064 2011 1R23 7 17 0.109 2013 1R24 7 24 0.154 2016 1R26 19 43 0.276

Enclosure to 1CAN031703 Page 6 of 9 Table 3.6.1 (continued)

SG B Year Outage Installed Cumulative  % Plugged 2005 Fabrication 0 0 0 2005 Baseline (1R19) 0 0 0 2007 First ISI 1R20 1 1 0.006 2008 1R21 5 6 0.038 2010 1R22 0 6 0.038 2011 1R23 9 15 0.096 2013 1R24 9 24 0.154 2016 1R26 13 37 0.237 Note: 15597 total tubes in each SG 3.7 The Results of Condition Monitoring, Including the Results of Tube Pulls and In-Situ Testing.

The condition monitoring requirements for the tubing performance criteria were met. There were no indications that exceeded performance criteria or in-situ screening limits. There was no tube pulls required.

The Condition Monitoring and Operational Assessment (CMOA) for 1R23 evaluated an Operational Assessment of three operating cycles totaling 4.40 Effective Full Power Years (EFPY) to 1R26 (EOC26). At the conclusion of cycle 26, 4.28 EFPY had passed; therefore, the 1R23 CMOA is still applicable. The following is a summary of the three damage mechanism results identified in 1R26:

3.7.1 Tie-Rod Bowing Two new Tie-Rods were detected that were experiencing bow during the 1R26 inspection. Both were in Span 1 Ring 1 of SG B. No new tie-rod bowing was detected in SG A.

The first span tie-rod bow is plotted as a function of time (in cooldown cycles) with added allowable limits in Figure 3.7.1 and Figure 3.7.2. For SG A, which has the longest history of tie-rod bowing, a pattern is developing that shows the tie-rods bowing to a point and then stagnating. This is most evident in the first span tie-rods where even the preventative tube plugging proximity signals are still detected for each tie-rod to accurately calculate the magnitude and direction of the tie-rod bow. It is believed the same relationship is true for the upper span tie-rods with the majority experiencing a similar pattern; however, due to the lack of information for some tie-rods (affected tubes plugged in prior outages), a conservative

Enclosure to 1CAN031703 Page 7 of 9 maximum possible bow is calculated which shows a step change in tie-rod bow. This is assumed to be conservative for plugging projections as some of these tie-rods still show stagnation after multiple outages with no change in affected tubes.

The tie-rods were evaluated for a projected bow assuming two heat up / cool down (HU/CD) cycles per fuel cycle until the next scheduled SG inspection at 1R29 for a total of six CD cycles, which is bounding of the historical thermal cycle performance observed at ANO-1. The maximum projected tie-rod bow at 1R29 are less than the maximum allowable tie-rod bow of 2.30; therefore, the existing 140 HU/CD cycle design life structural integrity evaluation remains valid. No preventative plugging of tubes adjacent to tie-rods was required at 1R26 for tie-rod bow projections through 1R29 for a total of six CD cycles.

Figure 3.7.1 SG A First Span Tie Rod Bowing with Allowable Limits (14 Tie Rods, 3 Rings) 2.2 Ring 1 Ring 2 2.0 Ring 3 Historical Projections 1.8 Rod-Tube Contact Hot Tube-Tube Contact Hot Second Tube-Tube Contact Hot 1.6 Estimated 1R29 Affect Tube Plugged 2.0 CD Cycles per Fuel Cycle 1.4 Tie Rod Bow, inches 1.2 1.0 0.8 0.6 0.4 0.2 0.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1R19 1R20 1R2 1R22 1R23 1R24 1R26 Cooldown Cycles

Enclosure to 1CAN031703 Page 8 of 9 Figure 3.7.2 SG B First Span Tie Rod Bowing with Allowable Limits (10 Tie Rods, 2 Rings) 2.2 Ring 1 Ring 2 2.0 Ring 3 Historical Projections 1.8 Rod-Tube Contact Hot Tube-Tube Contact hot 2nd Tube-Tube Contact Hot 1.6 3 Cylce OA Affected Tubes Plugged 2.0 CD Cycles per Fuel Cycle 1.4 Tie Rod Bow, inches 1.2 1.0 0.8 0.6 0.4 0.2 0.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1R19 1R20 1R21 1R22 1R23 1R24 1R26 Cooldown Cycles 3.7.2 TSP Wear There were 536 new TSP wear indications in SG A and 531 new TSP wear indications in SG B.

The average wear depth was 10.55% through-wall (TW) in SG A and 11.70% TW in SG B. The largest TSP wear indication was 44% TW in SG B. One drilled TSP wear indication was found in SG B at the 15th support plate and sized at 19% TW using a qualified +Point technique.

Table 3.7.1 summarizes the broached TSP wear detected during the 1R26 inspection.

Enclosure to 1CAN031703 Page 9 of 9 Table 3.7.1 Summary of 1R26 Broached TSP Wear Number of New and Repeat Depths Growth Rate of Repeats SG Indications (% TW) (% TW / EFPY)

New Repeat Average Upper 95th Maximum Average Upper 95th Maximum A 536 1465 10.55 17 41 0.31 1.40 3.97 B 531 1387 11.70 22 44 0.26 1.40 6.07 3.7.3 TTW The new Bobbin TTW indications had the 1R23 raw ECT data reviewed. Almost all new indications had a signal that was near the reporting threshold in 1R23 resulting in only a few indications that were truly new in 1R26. Table 3.7.2 summarizes the TTW indications detected during the 1R26 inspections.

Table 3.7.2 Summary of 1R26 TTW Number of New and Repeat Depths Growth Rate of Repeats SG Indications (% TW) (% TW / EFPY)

New Repeat Average Upper 95th Maximum Average Upper 95th Maximum A 44 49 10.11 14 16 0.39 0.68 0.68 B 58 84 10.74 15 23 0.27 0.68 1.35

Attachment 1 SG A TTW Indications to 1CAN031703 Page 1 of 3 Attachment 1 SG A TTW Indications ROW COL VOLTS %TW TSP Elevation (Inches) 29 58 0.37 10 08S 18.07 29 59 0.34 9 08S 17.75 42 22 0.33 9 08S 18.98 43 22 0.50 12 08S 19.06 45 88 0.29 9 08S 18.57 46 21 0.27 8 08S 18.69 46 89 0.35 10 08S 18.65 47 21 0.26 8 08S 18.73 50 22 0.21 7 08S 17.62 50 23 0.42 11 08S 17.68 57 23 0.44 11 08S 19.11 58 24 0.26 8 08S 19.40 61 30 0.67 14 08S 19.20 62 29 0.80 15 08S 18.88 65 31 0.31 9 08S 19.01 66 30 0.32 9 08S 19.05 68 30 0.31 9 08S 18.36 69 30 0.25 8 08S 18.32 69 31 0.36 10 08S 18.91 70 30 0.43 11 08S 18.93 71 30 0.29 9 08S 18.63 71 109 0.29 9 08S 18.68 71 110 0.61 13 08S 18.85 72 29 0.29 9 08S 18.51 72 107 0.44 11 08S 18.68 72 108 0.44 11 08S 18.66 72 109 0.34 9 08S 18.64 72 110 0.56 12 08S 18.77 73 22 0.24 8 08S 17.95 73 23 0.23 8 08S 17.98 to 1CAN031703 Page 2 of 3 ROW COL VOLTS %TW TSP Elevation (Inches) 73 32 0.31 9 08S 18.35 74 22 0.36 10 08S 18.02 74 23 0.33 9 08S 18.19 74 31 0.33 9 08S 17.67 74 108 0.33 9 08S 18.2 74 109 0.81 15 08S 18.37 74 110 0.95 16 08S 18.39 75 108 0.49 11 08S 18.00 75 109 0.54 12 08S 17.85 76 24 0.33 9 08S 19.02 77 22 0.34 9 08S 17.25 77 24 0.23 8 08S 18.49 77 25 0.43 11 08S 18.99 77 108 0.42 11 08S 17.34 77 109 0.61 13 08S 17.67 78 21 0.41 10 08S 17.90 78 111 0.20 7 06S 19.77 79 111 0.31 9 06S 19.86 81 21 0.51 12 08S 18.37 81 110 0.57 12 08S 18.15 81 111 0.90 16 08S 18.63 81 112 0.37 10 07S 20.00 82 20 0.38 10 08S 18.36 82 31 0.35 10 08S 18.96 82 110 0.41 10 08S 18.58 82 111 0.37 10 07S 20.38 83 31 0.34 9 08S 18.19 87 113 0.26 8 06S 19.90 88 27 0.47 11 08S 18.95 88 28 0.30 9 08S 18.26 88 112 0.32 9 06S 19.70 89 27 0.42 11 08S 19.02 to 1CAN031703 Page 3 of 3 ROW COL VOLTS %TW TSP Elevation (Inches) 89 28 0.27 8 08S 18.21 90 106 0.68 14 07S 19.13 91 108 0.65 13 07S 19.30 99 101 0.40 10 08S 17.99 100 100 0.35 10 08S 18.16 107 87 0.30 9 08S 18.64 107 88 0.36 10 08S 18.94 117 35 0.48 11 08S 18.79 117 60 0.30 9 07S 19.69 117 61 0.33 9 07S 19.62 117 88 0.30 9 08S 18.76 118 35 0.50 12 08S 18.50 118 86 0.30 9 07S 20.71 118 87 0.39 10 08S 18.82 118 90 0.34 9 07S 20.14 119 44 0.50 12 08S 18.11 119 45 0.32 9 08S 18.11 119 70 0.43 11 08S 18.49 119 71 0.43 11 08S 18.48 119 84 0.33 9 07S 19.39 119 88 0.25 8 07S 20.08 120 44 0.27 8 08S 18.34 120 45 0.32 9 08S 18.38 120 73 0.42 11 08S 17.64 121 73 0.48 11 08S 17.53 124 62 0.41 10 06S 19.92 124 63 0.42 11 06S 20.08 126 47 0.22 7 08S 18.29 126 48 0.29 9 08S 18.58 126 52 0.43 11 08S 17.89 127 51 0.48 11 08S 17.93

Attachment 2 SG B TTW Indications to 1CAN031703 Page 1 of 5 Attachment 2 SG B TTW Indications ROW COL VOLTS %TW TSP Elevation (Inches) 20 51 0.53 12 08S 17.83 20 52 0.56 12 08S 18.87 21 47 0.46 11 08S 18.44 21 48 0.24 8 08S 18.63 21 50 0.41 10 08S 19.23 21 50 0.74 14 07S 19.97 21 51 0.76 15 07S 20.06 21 52 0.39 10 08S 18.95 21 53 0.32 9 08S 18.90 22 48 0.26 8 08S 18.41 22 49 0.50 12 08S 18.79 22 51 0.50 12 08S 19.34 22 62 0.60 13 08S 18.94 22 63 0.49 11 08S 19.36 23 59 0.34 9 08S 17.87 24 56 0.52 12 08S 17.87 25 71 0.56 12 08S 17.80 25 72 0.84 15 08S 17.78 26 39 0.50 12 08S 18.42 26 40 0.52 12 08S 18.35 26 67 0.47 11 08S 18.11 26 72 0.41 10 08S 17.80 26 73 0.47 11 08S 17.30 27 69 0.43 11 08S 18.23 28 43 0.45 11 08S 19.71 28 67 0.57 12 07S 20.38 28 68 0.37 10 08S 18.61 28 68 0.56 12 07S 20.06 28 69 0.49 11 08S 18.75 to 1CAN031703 Page 2 of 5 ROW COL VOLTS %TW TSP Elevation (Inches) 28 76 0.77 15 08S 18.05 28 77 0.93 16 08S 18.08 29 44 0.37 10 08S 19.86 29 62 0.23 8 08S 18.63 29 63 0.27 8 08S 18.71 29 68 0.30 9 08S 18.03 29 76 0.35 10 08S 18.60 29 77 0.45 11 08S 18.76 30 69 0.23 8 08S 18.09 30 71 0.21 7 08S 18.75 30 72 0.40 10 08S 18.89 31 34 0.70 14 08S 18.89 31 35 0.64 13 08S 19.07 31 38 0.33 9 08S 18.09 31 39 0.60 13 08S 18.36 31 61 0.21 7 07S 19.53 31 62 0.51 12 08S 19.20 31 62 0.48 11 07S 19.80 31 63 0.44 11 08S 19.52 31 74 0.35 10 08S 18.31 32 33 0.40 10 08S 19.41 32 36 0.29 9 08S 17.74 32 43 0.19 7 08S 19.13 32 74 0.36 10 08S 18.96 33 32 0.32 9 08S 19.48 33 34 0.30 9 08S 19.23 33 38 0.49 11 08S 17.79 33 44 0.34 9 08S 19.38 33 80 0.54 12 08S 19.73 33 82 0.27 8 08S 19.25 34 27 0.47 11 08S 19.23 to 1CAN031703 Page 3 of 5 ROW COL VOLTS %TW TSP Elevation (Inches) 34 33 0.21 7 08S 18.32 34 55 1.30 20 08S 19.30 34 56 1.22 19 08S 19.04 34 82 0.53 12 08S 19.76 34 84 0.40 10 08S 19.62 34 89 0.30 9 08S 18.58 34 90 0.40 10 08S 18.05 35 28 0.38 10 08S 19.45 36 31 0.33 9 08S 18.79 37 32 0.36 10 08S 18.80 38 29 0.49 11 08S 18.87 38 86 0.44 11 08S 20.27 38 87 0.52 12 08S 19.80 39 29 0.42 11 08S 19.30 39 37 0.36 10 08S 18.28 39 53 1.60 22 08S 18.93 39 54 1.46 21 08S 18.45 39 91 0.25 8 08S 19.50 39 92 0.42 11 08S 19.87 40 36 0.39 10 08S 18.41 43 25 0.44 11 08S 18.20 44 25 0.31 9 08S 19.28 44 26 0.49 11 08S 18.22 45 26 0.28 8 08S 19.52 46 21 0.46 11 08S 18.07 46 100 0.80 15 08S 18.79 47 21 0.32 9 08S 18.35 47 99 0.70 14 08S 18.79 55 21 0.36 10 08S 18.28 55 22 0.32 9 08S 18.69 57 26 0.25 8 08S 19.59 to 1CAN031703 Page 4 of 5 ROW COL VOLTS %TW TSP Elevation (Inches) 58 26 0.30 9 08S 19.35 59 20 0.39 10 08S 19.00 60 21 0.37 10 08S 18.90 66 21 0.37 10 08S 18.09 66 22 0.25 8 08S 18.34 67 22 0.20 7 08S 18.30 67 23 0.29 9 08S 18.31 67 108 0.47 11 08S 18.60 68 110 0.41 10 08S 18.42 74 114 0.27 8 08S 17.59 75 114 0.33 9 08S 18.28 77 20 0.17 6 08S 18.82 78 20 0.30 9 08S 18.33 89 25 0.54 12 08S 18.85 90 25 0.52 12 08S 19.06 94 24 0.33 9 08S 18.57 94 25 0.31 9 08S 18.42 96 109 0.22 8 08S 18.30 97 109 0.31 9 08S 18.36 102 102 0.30 9 08S 17.38 102 103 0.24 8 08S 17.75 103 21 0.35 10 08S 17.99 103 22 0.33 9 08S 17.74 105 23 0.35 10 08S 18.94 106 24 0.39 10 08S 18.87 109 97 0.41 10 08S 18.19 109 98 0.34 9 08S 18.16 114 82 0.50 12 08S 19.25 114 83 0.62 13 08S 19.08 115 30 0.59 13 08S 18.20 115 31 0.76 15 08S 18.06 to 1CAN031703 Page 5 of 5 ROW COL VOLTS %TW TSP Elevation (Inches) 116 29 1.73 23 07S 20.30 117 29 1.80 23 07S 20.37 117 89 0.27 8 08S 18.65 118 28 0.30 9 08S 18.34 118 29 0.40 10 08S 18.75 118 88 0.38 10 08S 18.62 119 25 0.85 15 07S 20.83 119 28 0.30 9 07S 20.46 119 29 0.43 11 07S 20.46 120 25 0.79 15 07S 20.83 123 32 0.34 9 08S 18.60 124 32 0.36 10 08S 18.20 128 44 0.38 10 07S 19.99 128 45 0.11 5 08S 18.64 128 45 0.34 9 07S 20.12 128 59 0.29 9 08S 18.76 128 60 0.26 8 08S 18.50 129 29 0.31 9 08S 17.83 129 30 0.42 11 08S 18.19 129 46 0.17 6 08S 18.50

Attachment 3 SG A TSP Wear Indications to 1CAN031703 Page 1 of 62 Attachment 3 SG A TSP Wear Indications ROW COL VOLTS %TW TSP Elevation (Inches) 1 6 0.33 14 13S -0.65 1 16 0.14 7 10S 0.48 1 17 0.13 7 10S 0.49 1 19 0.16 9 10S 0.51 1 19 0.17 9 13S -0.76 1 23 0.15 8 10S 0.44 2 4 0.19 9 13S -0.65 3 5 0.20 10 13S -0.67 3 11 0.07 4 10S 0.58 3 23 0.14 8 10S 0.06 3 27 0.17 10 13S -0.76 4 6 0.27 14 13S -0.68 4 19 0.28 12 13S 0.38 4 24 0.10 6 10S 0.04 4 25 0.32 16 10S 0.11 5 3 0.22 11 13S -0.65 5 18 0.13 7 12S -0.76 5 19 0.16 7 12S -0.77 5 19 0.23 10 10S -0.67 5 20 0.34 17 10S -0.67 5 22 0.18 10 10S -0.61 5 22 0.23 12 13S 0.41 5 23 0.27 11 10S -0.65 5 24 0.09 5 12S -0.76 5 25 0.17 10 14S 0.31 5 25 0.22 12 12S -0.71 5 25 0.22 12 13S 0.35 5 26 0.16 9 10S -0.64 5 26 0.29 15 12S -0.78 5 26 0.40 20 13S 0.37 to 1CAN031703 Page 2 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 5 27 0.17 10 12S -0.80 5 27 0.17 10 13S -0.74 5 27 0.19 11 10S -0.64 5 28 0.11 7 10S -0.64 5 28 0.35 18 10S 0.17 5 29 0.42 18 10S 0.09 6 2 0.21 10 13S -0.67 6 6 0.42 20 10S -0.65 6 9 0.43 17 10S -0.65 6 13 0.19 9 10S -0.65 6 15 0.40 16 10S -0.65 6 17 0.21 9 10S -0.68 6 18 0.16 9 10S -0.67 6 19 0.13 6 12S -0.79 6 19 0.25 11 13S 0.34 6 19 0.32 13 10S -0.67 6 20 0.18 10 15S 0.38 6 20 0.23 12 09S -0.65 6 21 0.12 6 12S -0.79 6 24 0.30 13 13S 0.36 6 25 0.10 6 12S -0.78 6 26 0.08 5 12S -0.78 6 26 0.31 16 13S 0.35 6 29 0.18 10 09S -0.67 6 30 0.13 8 12S -0.77 6 30 0.18 10 09S -0.67 6 30 0.20 11 13S -0.72 6 31 0.24 13 12S -0.77 6 31 0.33 17 09S -0.69 6 32 0.14 8 10S -0.65 6 32 0.18 10 12S -0.79 6 32 0.20 11 10S 0.11 to 1CAN031703 Page 3 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 6 33 0.14 8 10S 0.06 6 35 0.13 8 15S 0.33 6 37 0.17 10 13S 0.33 6 38 0.25 13 13S 0.37 6 39 0.17 10 14S 0.26 6 41 0.16 9 09S 0.40 7 1 0.23 11 13S -0.63 7 6 0.10 6 13S 0.47 7 6 0.21 11 13S -0.64 7 6 0.24 13 10S -0.68 7 9 0.39 16 10S -0.68 7 10 0.61 23 10S -0.69 7 12 0.18 10 10S -0.65 7 13 0.22 10 10S -0.70 7 14 0.25 13 10S -0.72 7 16 0.20 11 13S 0.45 7 17 0.24 10 09S -0.72 7 17 0.45 17 10S -0.67 7 21 0.28 12 09S -0.67 7 28 0.16 9 10S 0.41 7 32 0.23 12 12S 0.39 7 32 0.26 14 09S -0.69 7 33 0.21 12 09S -0.67 7 33 0.28 15 13S 0.37 7 34 0.23 13 12S -0.77 7 35 0.17 10 10S 0.09 7 35 0.18 10 12S -0.77 7 37 0.2 11 10S 0.15 7 38 0.13 8 10S 0.17 7 38 0.17 10 12S -0.80 8 1 0.25 12 13S -0.63 8 9 0.33 14 10S -0.63 to 1CAN031703 Page 4 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 8 11 0.25 11 10S -0.68 8 14 0.20 11 12S -0.72 8 14 0.29 15 10S -0.63 8 16 0.38 18 09S -0.67 8 17 0.49 20 09S -0.69 8 19 0.28 12 10S -0.65 8 19 0.47 18 09S -0.67 8 20 0.29 14 09S -0.60 8 29 0.17 10 12S -0.77 8 29 0.18 10 12S 0.37 8 34 0.20 11 09S -0.68 8 35 0.23 13 09S 0.44 8 36 0.17 10 15S 0.28 8 36 0.19 11 12S -0.77 8 37 0.19 11 12S -0.79 8 39 0.16 9 15S -0.81 8 39 0.18 11 14S 0.26 8 39 0.23 13 09S -0.68 8 39 0.32 17 12S -0.79 8 40 0.23 13 12S -0.79 8 41 0.27 14 09S -0.64 8 45 0.16 10 14S 0.24 8 49 0.21 12 14S -0.86 8 50 0.18 10 14S 0.28 8 51 0.14 7 14S 0.26 9 2 0.20 10 13S 0.56 9 8 0.21 9 10S -0.61 9 9 0.60 23 10S -0.69 9 10 0.10 6 10S 0.54 9 11 0.32 13 13S -0.66 9 12 0.10 6 09S 0.47 9 12 0.48 22 10S -0.61 to 1CAN031703 Page 5 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 9 17 0.12 7 09S 0.45 9 31 0.24 12 12S -0.74 9 42 0.21 12 13S 0.35 9 43 0.35 17 09S -0.66 9 54 0.18 10 14S 0.26 9 57 0.25 13 13S -0.74 10 1 0.24 12 13S 0.54 10 3 0.43 18 13S 0.54 10 9 0.66 24 10S -0.66 10 10 0.36 17 10S -0.61 10 12 0.11 6 10S 0.37 10 12 1.30 37 10S -0.62 10 13 0.13 7 10S -0.63 10 14 0.32 13 10S -0.70 10 15 0.28 14 10S -0.65 10 36 0.17 10 15S 0.29 10 40 0.28 15 12S -0.79 10 53 0.19 10 14S 0.27 10 54 0.19 11 14S 0.24 10 56 0.12 7 14S 0.24 10 57 0.19 10 14S 0.25 10 58 0.21 12 14S 0.24 10 60 0.11 6 10S -0.11 10 61 0.12 6 14S 0.23 10 61 0.21 10 13S 0.32 10 62 0.22 11 14S 0.26 10 63 0.30 13 14S 0.23 11 1 0.40 17 13S 0.58 11 2 0.16 8 14S -0.67 11 5 0.34 15 10S -0.64 11 6 0.11 6 10S 0.54 11 8 0.20 11 12S -0.63 to 1CAN031703 Page 6 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 11 8 0.39 18 10S -0.63 11 10 0.17 9 10S -0.61 11 11 0.22 10 13S 0.45 11 11 0.36 15 10S -0.61 11 12 0.87 29 10S -0.66 11 13 1.05 32 10S -0.65 11 14 0.11 6 12S -0.62 11 14 0.45 20 10S -0.47 11 15 0.24 12 10S -0.67 11 16 0.30 14 10S -0.64 11 27 0.20 11 15S 0.31 11 48 0.18 10 15S 0.26 11 49 0.22 12 15S -0.88 11 50 0.23 13 15S 0.28 11 51 0.29 15 12S -0.83 11 52 0.11 7 10S -0.74 11 55 0.15 8 09S 0.42 11 59 0.17 10 14S 0.22 11 64 0.19 10 10S 0.09 11 65 0.13 6 10S -0.11 11 68 0.23 11 13S -0.80 12 1 0.17 9 13S 0.54 12 2 0.18 8 13S 0.53 12 7 0.40 19 10S -0.61 12 8 0.24 11 13S 0.54 12 8 0.33 14 10S -0.65 12 8 0.36 15 12S -0.61 12 9 0.41 19 10S -0.61 12 11 0.59 23 10S -0.66 12 12 0.18 10 10S -0.61 12 13 0.35 14 10S -0.65 12 14 0.26 13 10S -0.67 to 1CAN031703 Page 7 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 12 15 0.11 6 10S 0.47 12 15 0.24 12 10S -0.69 12 22 0.13 7 09S -0.65 12 37 0.22 12 15S 0.24 12 42 0.20 11 12S 0.38 12 45 0.19 11 15S 0.26 12 48 0.24 13 15S -0.83 12 57 0.10 6 15S -0.86 13 1 0.19 9 13S 0.53 13 10 0.34 14 10S -0.65 13 11 0.35 17 10S -0.62 13 12 0.32 14 10S -0.67 13 13 0.49 20 10S -0.69 13 14 0.23 10 10S -0.69 13 16 0.47 18 10S -0.67 13 17 0.24 12 09S -0.60 13 17 0.96 33 10S 0.00 13 38 0.23 12 15S 0.29 13 57 0.15 9 09S -0.69 13 59 0.16 9 12S -0.85 13 60 0.14 8 09S 0.47 13 61 0.22 12 12S -0.83 13 67 0.17 10 14S 0.24 13 74 0.39 17 13S -0.76 14 11 0.22 11 10S -0.60 14 12 0.13 6 12S -0.63 14 15 0.17 9 11S -0.65 14 15 0.28 14 10S -0.67 14 16 0.25 11 14S -0.65 14 16 0.30 13 10S -0.67 14 17 0.11 6 07S -0.60 14 18 0.26 11 10S -0.67 to 1CAN031703 Page 8 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 14 19 0.36 17 10S -0.67 14 42 0.20 11 15S 0.27 14 52 0.20 11 15S 0.24 14 74 0.15 8 10S -0.05 14 77 0.20 10 13S -0.86 15 5 0.21 11 12S -0.63 15 7 0.21 11 10S -0.60 15 10 0.24 11 10S -0.63 15 15 0.21 11 11S -0.69 15 16 0.24 11 11S -0.67 15 16 0.27 12 10S -0.65 15 19 0.22 11 10S -0.67 15 49 0.06 4 09S -0.73 15 72 0.18 10 09S -0.71 15 80 0.38 17 13S -0.83 16 4 0.10 5 10S 0.27 16 6 0.23 12 13S -0.61 16 60 0.19 10 15S -0.90 16 61 0.16 9 15S -0.90 16 74 0.25 13 09S 0.42 16 76 0.11 7 10S 0.13 16 76 0.23 13 14S 0.25 17 5 0.56 22 10S -0.62 17 62 0.28 15 15S 0.24 17 64 0.18 10 15S 0.18 17 67 0.18 10 15S -0.90 17 68 0.20 11 10S -0.77 17 68 0.22 12 15S -0.91 17 76 0.21 12 09S -0.70 17 76 0.27 15 15S -0.95 17 77 0.19 10 14S 0.25 18 7 0.28 12 12S -0.65 to 1CAN031703 Page 9 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 18 21 0.17 8 09S -0.64 18 77 0.25 15 09S 0.40 18 78 0.37 14 09S -0.70 18 80 0.19 8 10S 0.13 19 7 0.30 13 10S -0.58 19 66 0.13 8 09S -0.75 19 71 0.18 8 12S 0.34 19 75 0.30 12 12S 0.34 19 80 0.38 20 09S -0.72 19 82 0.17 11 10S 0.13 19 87 0.34 15 13S -0.83 20 80 0.38 15 09S -0.72 20 81 0.19 12 09S 0.39 20 82 0.33 13 12S 0.32 20 85 0.17 11 14S 0.22 20 89 0.21 11 12S -0.78 21 45 0.10 5 08S 0.46 21 82 0.17 7 10S -0.77 21 84 0.21 9 10S 0.16 21 84 0.17 9 10S 0.18 21 84 0.23 11 12S -0.87 21 84 0.29 12 12S -0.86 21 85 0.18 11 14S 0.27 21 87 0.19 11 12S -0.79 21 90 0.47 20 12S -0.76 22 58 0.12 5 08S -0.70 22 84 0.36 14 10S -0.81 22 85 0.18 11 10S 0.33 22 85 0.18 11 09S 0.44 22 85 0.19 12 11S 0.28 22 85 0.25 14 09S -0.74 22 85 0.26 15 12S -0.83 to 1CAN031703 Page 10 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 22 85 0.37 19 10S -0.74 22 86 0.35 14 12S -0.83 22 88 0.29 12 12S -0.81 22 92 0.21 11 12S -0.79 22 92 0.40 18 13S -0.84 23 33 0.09 5 08S 0.48 23 40 0.13 7 08S -0.70 23 44 0.14 8 08S -0.70 23 85 0.55 20 10S -0.78 23 86 0.84 29 10S -0.78 23 87 0.62 21 12S -0.81 23 88 0.16 10 12S -0.85 23 88 0.16 10 12S 0.33 23 89 0.27 11 12S 0.32 23 93 0.18 9 12S -0.81 23 94 0.29 14 12S -0.81 24 30 0.21 11 08S -0.67 24 31 0.16 8 08S -0.66 24 38 0.16 8 08S 0.46 24 48 0.24 14 08S -0.70 24 53 0.13 6 08S 0.40 24 82 0.27 11 15S -0.90 24 83 0.26 15 12S 0.29 24 83 0.45 22 10S -0.81 24 84 0.25 10 10S -0.79 24 85 0.10 7 10S 0.17 24 85 0.18 11 12S -0.85 24 86 0.26 11 10S 0.07 24 90 0.28 13 12S -0.81 24 91 0.21 11 12S -0.76 25 30 0.10 6 08S 0.48 25 31 0.09 5 08S 0.46 to 1CAN031703 Page 11 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 25 34 0.16 8 08S -0.66 25 40 0.11 6 08S 0.44 25 42 0.19 10 08S -0.70 25 47 0.12 6 08S 0.46 25 50 0.11 6 08S -0.72 25 54 0.14 9 08S 0.44 25 56 0.14 9 08S -0.68 26 65 0.22 9 08S -0.70 26 67 0.12 5 08S -0.70 26 71 0.08 4 08S -0.70 26 91 0.31 12 12S -0.85 26 92 0.16 10 12S -0.83 26 93 0.42 16 12S -0.83 26 94 0.16 10 12S -0.85 26 94 0.19 12 10S 0.13 26 95 0.11 5 10S 0.11 26 99 0.15 8 12S -0.83 27 15 0.23 12 10S -0.62 27 27 0.16 8 08S -0.67 27 28 0.08 4 08S 0.50 27 29 0.11 6 08S 0.47 27 30 0.14 7 08S -0.67 27 31 0.20 10 08S -0.65 27 32 0.14 8 08S -0.68 27 34 0.21 10 08S -0.70 27 36 0.12 7 08S 0.46 27 36 0.17 9 08S -0.72 27 38 0.16 9 08S -0.68 27 39 0.15 8 08S 0.46 27 39 0.21 10 08S -0.73 27 40 0.16 8 08S -0.68 27 41 0.18 9 08S -0.70 to 1CAN031703 Page 12 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 27 42 0.13 7 09S -0.72 27 43 0.14 7 08S -0.72 27 45 0.07 4 08S -0.57 27 45 0.14 7 07S 0.48 27 46 0.16 8 08S 0.46 27 46 0.21 11 08S -0.72 27 49 0.22 11 08S -0.75 27 51 0.12 6 08S 0.44 27 51 0.30 14 08S -0.72 27 54 0.15 8 08S -0.70 27 55 0.11 6 08S -0.67 27 58 0.12 6 08S -0.70 27 63 0.07 4 08S -0.67 27 64 0.14 7 08S 0.40 27 66 0.10 5 08S 0.44 27 69 0.11 6 08S 0.38 27 71 0.06 4 08S 0.45 27 73 0.10 5 08S 0.45 27 92 0.16 10 15S 0.24 27 94 0.33 18 12S -0.85 27 95 0.55 20 12S -0.83 27 97 0.13 6 10S 0.09 27 102 0.14 7 10S -0.83 28 6 0.20 10 12S -0.65 28 15 0.35 16 10S -0.61 28 16 0.06 3 10S 0.44 28 27 0.19 10 08S -0.65 28 28 0.12 7 08S 0.46 28 31 0.14 7 08S 0.45 28 31 0.17 9 08S -0.69 28 32 0.19 10 08S -0.67 28 35 0.20 10 08S -0.69 to 1CAN031703 Page 13 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 28 38 0.16 9 08S -0.69 28 40 0.24 12 08S -0.73 28 41 0.14 7 08S 0.46 28 41 0.22 11 09S -0.69 28 41 0.26 12 08S -0.69 28 42 0.17 9 08S -0.73 28 43 0.11 6 07S -0.70 28 43 0.15 8 08S 0.44 28 43 0.22 11 08S -0.75 28 46 0.20 10 08S -0.76 28 54 0.09 5 08S 0.49 28 55 0.06 3 08S -0.67 28 56 0.16 8 08S -0.70 28 57 0.09 5 08S 0.43 28 57 0.10 6 08S -0.74 28 96 0.27 13 12S -0.83 28 96 0.39 17 12S 0.29 28 97 0.20 10 12S -0.83 28 98 0.22 11 12S -0.80 29 30 0.12 7 08S 0.46 29 31 0.25 12 08S -0.70 29 32 0.28 13 08S -0.68 29 33 0.12 6 08S 0.48 29 33 0.17 9 08S -0.72 29 34 0.14 7 08S 0.46 29 34 0.31 14 08S -0.70 29 41 0.11 6 08S -0.69 29 42 0.24 12 08S -0.72 29 44 0.19 9 08S -0.72 29 49 0.18 9 08S -0.75 29 51 0.21 11 08S -0.76 29 56 0.09 5 08S 0.45 to 1CAN031703 Page 14 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 29 56 0.16 8 08S -0.72 29 57 0.12 6 08S 0.40 29 58 0.17 9 08S 0.45 29 58 0.27 13 08S -0.70 29 60 0.09 5 08S 0.47 29 61 0.23 11 08S 0.44 29 61 0.25 12 08S -0.72 29 62 0.09 5 08S -0.72 29 63 0.11 6 08S 0.46 29 63 0.19 10 08S -0.72 29 64 0.11 6 08S 0.47 29 66 0.10 6 08S 0.45 29 71 0.20 10 08S 0.39 29 72 0.12 6 08S 0.43 29 73 0.14 7 08S 0.46 29 97 0.76 28 12S 0.30 29 98 0.15 8 12S -0.85 29 98 0.27 13 12S 0.32 29 99 0.24 11 12S -0.85 30 31 0.27 13 08S -0.69 30 32 0.20 10 08S -0.71 30 33 0.29 14 08S -0.71 30 34 0.22 11 08S -0.68 30 36 0.31 15 08S -0.70 30 37 0.24 12 08S -0.71 30 38 0.23 11 08S -0.72 30 39 0.22 11 08S -0.73 30 40 0.19 10 08S -0.71 30 41 0.19 10 08S -0.73 30 42 0.20 10 08S -0.72 30 47 0.19 10 08S 0.48 30 49 0.19 10 08S -0.69 to 1CAN031703 Page 15 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 30 53 0.19 10 08S -0.71 30 56 0.06 3 08S -0.67 30 67 0.10 5 08S 0.46 30 68 0.17 9 08S -0.72 30 70 0.07 4 08S 0.45 30 72 0.09 5 08S 0.45 30 73 0.12 6 08S 0.44 30 77 0.09 5 08S 0.43 30 98 0.21 11 14S 0.20 30 98 0.34 16 12S -0.83 30 99 0.23 11 10S 0.07 30 99 0.23 11 12S -0.87 30 99 0.22 11 12S 0.31 30 99 0.22 11 14S 0.22 30 100 0.17 9 12S -0.83 31 30 0.18 9 08S -0.69 31 32 0.13 7 08S 0.52 31 32 0.27 13 08S -0.70 31 33 0.14 7 08S 0.47 31 34 0.27 13 08S -0.71 31 37 0.33 15 08S -0.70 31 38 0.25 12 08S -0.71 31 41 0.22 11 08S -0.72 31 57 0.22 11 08S -0.70 31 67 0.13 7 08S 0.44 31 68 0.11 6 08S 0.40 31 70 0.16 8 08S 0.40 31 75 0.18 9 08S 0.39 31 79 0.13 7 08S 0.39 31 98 0.28 13 10S -0.76 31 100 0.16 9 12S 0.27 31 100 0.23 12 10S 0.11 to 1CAN031703 Page 16 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 31 101 0.15 8 10S 0.11 32 23 0.13 7 08S -0.68 32 25 0.12 7 08S 0.52 32 25 0.26 13 08S -0.63 32 29 0.15 8 08S 0.44 32 29 0.20 10 08S -0.62 32 31 0.12 7 08S 0.49 32 32 0.10 6 08S 0.52 32 32 0.22 11 08S -0.71 32 33 0.25 12 08S -0.68 32 36 0.08 5 08S -0.71 32 47 0.19 10 08S -0.70 32 48 0.22 11 08S -0.71 32 49 0.24 12 08S -0.72 32 50 0.19 10 08S -0.76 32 51 0.20 10 08S -0.69 32 52 0.19 10 08S -0.76 32 53 0.25 12 08S -0.67 32 54 0.26 13 08S -0.73 32 65 0.15 8 08S 0.46 32 67 0.09 5 08S 0.46 32 70 0.09 5 08S 0.47 32 73 0.12 6 08S 0.44 32 76 0.09 5 08S 0.38 32 81 0.20 10 08S -0.71 32 97 0.37 16 10S -0.76 32 98 0.11 6 11S 0.31 32 98 0.23 12 12S -0.83 32 98 0.30 14 12S 0.32 32 99 0.23 11 10S 0.15 32 99 0.29 13 12S 0.31 32 100 0.14 7 14S 0.23 to 1CAN031703 Page 17 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 32 100 0.16 8 10S 0.13 32 102 0.15 8 14S 0.18 33 18 0.22 11 08S -0.58 33 21 0.12 7 09S -0.67 33 21 0.17 9 08S -0.66 33 22 0.19 10 08S -0.65 33 23 0.10 6 08S 0.49 33 24 0.24 12 09S -0.67 33 29 0.24 12 08S -0.69 33 30 0.14 7 08S 0.44 33 31 0.27 13 08S -0.68 33 32 0.25 13 08S -0.69 33 34 0.21 11 08S -0.69 33 34 0.23 11 08S 0.47 33 36 0.26 13 08S -0.71 33 38 0.19 10 08S 0.47 33 38 0.20 10 09S -0.76 33 38 0.24 12 08S -0.73 33 43 0.18 10 08S -0.70 33 44 0.20 10 08S -0.70 33 45 0.24 12 08S -0.72 33 57 0.20 10 08S -0.70 33 60 0.20 10 08S -0.72 33 61 0.22 11 08S -0.72 33 66 0.24 12 08S -0.72 33 67 0.27 13 08S -0.72 33 71 0.14 8 08S 0.45 33 72 0.13 7 08S 0.44 33 75 0.19 10 08S 0.42 33 76 0.13 7 08S 0.44 33 77 0.14 7 08S 0.42 33 77 0.22 11 08S -0.71 to 1CAN031703 Page 18 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 33 78 0.18 9 08S 0.37 33 80 0.18 9 08S -0.72 33 103 0.19 10 12S -0.78 34 6 0.16 9 12S -0.63 34 6 0.18 10 09S -0.60 34 26 0.18 10 08S -0.66 34 27 0.22 11 08S -0.65 34 34 0.27 13 08S -0.72 34 36 0.11 6 08S -0.71 34 56 0.19 10 08S -0.72 34 57 0.23 12 08S -0.72 34 69 0.08 5 08S 0.47 34 75 0.15 8 08S -0.76 34 78 0.26 12 08S -0.72 34 79 0.10 6 08S 0.42 34 82 0.11 6 08S 0.45 34 103 0.26 13 10S -0.78 35 21 0.22 12 08S -0.55 35 23 0.11 7 08S 0.55 35 24 0.27 13 08S -0.63 35 35 0.20 11 08S -0.70 35 38 0.24 12 08S -0.69 35 48 0.21 11 08S -0.72 35 62 0.20 10 09S -0.77 35 62 0.27 13 08S -0.72 35 63 0.30 14 08S -0.72 35 76 0.12 6 08S 0.41 35 77 0.12 7 08S 0.47 35 80 0.09 5 08S 0.46 35 82 0.13 7 08S -0.73 35 82 0.19 9 08S 0.37 35 83 0.12 6 08S 0.44 to 1CAN031703 Page 19 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 35 84 0.15 7 08S 0.43 35 86 0.19 9 08S 0.39 35 87 0.07 4 08S 0.45 35 90 0.11 6 08S 0.39 35 106 0.14 7 11S 0.28 35 107 0.17 9 14S 0.25 35 107 0.19 10 10S 0.16 35 110 0.20 10 13S -0.85 36 19 0.12 7 08S 0.56 36 21 0.12 7 08S 0.56 36 22 0.14 8 08S 0.54 36 24 0.18 9 08S -0.56 36 25 0.17 9 08S -0.62 36 27 0.18 10 08S -0.66 36 30 0.18 9 08S -0.65 36 32 0.10 6 10S -0.74 36 69 0.24 12 08S -0.72 36 69 0.47 20 08S 0.39 36 78 0.10 5 08S 0.49 36 82 0.08 5 08S 0.47 36 84 0.16 8 08S 0.42 36 87 0.15 8 08S 0.39 36 89 0.22 11 08S 0.41 36 107 0.17 8 11S 0.33 36 108 0.20 10 10S 0.18 36 109 0.28 11 10S 0.18 37 7 0.10 6 10S 0.54 37 24 0.14 8 08S 0.51 37 39 0.28 13 08S -0.71 37 69 0.37 15 09S -0.74 37 77 0.14 6 08S 0.42 37 77 0.30 12 08S -0.72 to 1CAN031703 Page 20 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 37 84 0.10 5 08S 0.42 37 85 0.15 7 08S 0.39 37 86 0.21 10 08S 0.40 37 87 0.18 8 08S 0.41 37 88 0.14 7 08S 0.42 37 108 0.19 9 12S 0.25 37 110 0.21 10 10S 0.07 37 111 0.25 11 10S 0.13 38 18 0.20 10 08S -0.67 38 20 0.16 8 08S 0.54 38 23 0.22 12 08S -0.64 38 24 0.13 7 08S 0.52 38 25 0.21 11 08S -0.62 38 26 0.33 15 08S -0.67 38 27 0.22 12 08S -0.68 38 29 0.16 9 08S -0.70 38 31 0.18 10 09S 0.48 38 85 0.13 7 08S 0.42 38 86 0.26 11 08S -0.72 38 88 0.09 4 08S 0.37 38 89 0.17 9 08S 0.40 38 109 0.14 7 10S -0.81 38 110 0.16 7 11S 0.33 38 110 0.31 13 12S -0.83 38 111 0.10 5 10S -0.78 39 23 0.09 5 08S 0.48 39 25 0.11 7 08S 0.57 39 25 0.15 9 08S -0.62 39 27 0.12 7 08S 0.55 39 27 0.13 8 08S -0.64 39 32 0.13 7 08S 0.52 39 89 0.19 8 08S 0.41 to 1CAN031703 Page 21 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 39 111 0.25 11 12S -0.83 39 113 0.17 8 14S 0.20 40 19 0.14 8 08S 0.53 40 19 0.24 12 08S -0.60 40 23 0.26 14 08S -0.70 40 24 0.27 13 08S -0.65 40 25 0.30 15 08S -0.62 40 27 0.22 12 08S -0.55 40 28 0.19 10 08S -0.63 40 33 0.18 10 08S -0.72 40 87 0.32 13 08S -0.74 40 89 0.09 4 08S 0.41 40 89 0.33 13 08S -0.74 40 91 0.14 6 08S 0.41 40 92 0.19 9 08S 0.40 40 101 0.32 13 11S -0.85 41 20 0.16 8 08S -0.59 41 21 0.18 10 08S -0.64 41 22 0.23 11 08S -0.63 41 23 0.32 16 08S -0.64 41 24 0.23 11 08S -0.63 41 26 0.21 11 08S -0.61 41 27 0.25 13 08S -0.62 41 28 0.20 10 08S -0.63 41 29 0.24 13 08S -0.59 41 32 0.23 11 09S -0.70 41 93 0.17 8 08S 0.40 41 94 0.11 6 08S 0.41 42 5 0.14 8 10S 0.51 42 17 0.18 10 08S -0.60 42 17 0.20 11 09S 0.51 42 20 0.19 10 08S -0.61 to 1CAN031703 Page 22 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 42 22 0.22 11 08S -0.63 42 24 0.20 10 08S -0.61 42 25 0.19 10 08S -0.64 42 26 0.23 11 08S -0.65 42 30 0.16 8 08S -0.67 42 87 0.16 8 08S 0.43 43 14 0.09 5 08S 0.54 43 19 0.18 10 08S -0.64 43 20 0.27 13 08S -0.61 43 21 0.26 13 08S -0.66 43 24 0.21 10 08S -0.61 43 25 0.23 12 08S -0.64 43 26 0.24 12 08S -0.65 43 26 0.26 12 09S -0.65 43 27 0.21 11 08S -0.70 43 115 0.25 12 12S -0.80 44 15 0.09 5 08S 0.59 44 22 0.16 9 08S -0.68 44 23 0.21 11 08S -0.63 44 24 0.26 14 08S -0.59 44 29 0.23 11 08S -0.67 44 95 0.20 10 08S 0.43 44 96 0.15 8 08S 0.43 44 97 0.17 9 08S 0.45 45 1 0.20 10 13S 0.51 45 15 0.17 9 08S -0.63 45 20 0.19 11 09S -0.62 45 20 0.25 14 08S -0.55 45 22 0.24 12 08S -0.66 45 23 0.19 10 08S -0.64 45 24 0.21 12 09S -0.66 45 24 0.28 15 08S -0.64 to 1CAN031703 Page 23 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 45 25 0.22 11 08S -0.67 45 91 0.14 7 08S 0.40 45 96 0.13 7 08S 0.43 45 97 0.20 10 08S 0.45 45 115 0.18 9 12S -0.85 46 11 0.20 10 11S -0.65 46 20 0.17 9 08S -0.58 46 22 0.16 8 08S 0.55 46 23 0.11 6 08S 0.58 46 23 0.35 16 08S -0.62 46 24 0.28 14 08S -0.64 46 24 0.28 14 09S -0.64 46 25 0.18 10 08S -0.77 46 26 0.23 11 08S -0.70 46 92 0.11 6 08S 0.45 46 94 0.14 7 08S 0.45 46 96 0.18 9 08S 0.40 46 117 0.11 6 12S -0.84 47 7 0.10 6 10S 0.54 47 17 0.14 8 08S -0.60 47 21 0.23 12 08S -0.62 47 23 0.26 13 08S -0.62 47 82 0.14 8 08S 0.41 47 88 0.16 8 08S -0.75 47 94 0.11 6 08S -0.75 47 113 0.16 8 10S -0.80 47 118 0.15 8 14S 0.21 48 4 0.22 11 11S -0.61 48 22 0.22 11 08S -0.62 48 25 0.30 14 08S -0.68 48 27 0.26 13 08S -0.54 48 28 0.18 10 08S -0.66 to 1CAN031703 Page 24 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 48 98 0.11 6 08S 0.43 48 112 0.22 11 14S 0.18 49 8 0.15 9 09S 0.56 49 17 0.18 9 08S -0.61 49 25 0.21 11 08S -0.59 49 29 0.22 11 08S -0.67 49 91 0.18 9 08S 0.40 49 93 0.27 13 08S 0.42 49 100 0.17 8 08S 0.43 49 102 0.15 7 10S -0.84 49 102 0.16 8 07S 0.43 49 115 0.18 9 10S -0.78 50 31 0.17 10 08S -0.68 50 92 0.19 9 08S 0.43 50 94 0.16 8 08S 0.43 50 95 0.20 10 08S 0.45 50 96 0.24 11 08S -0.72 51 1 0.29 13 13S -0.58 51 7 0.37 18 10S 0.20 51 18 0.28 13 08S -0.56 51 22 0.21 11 08S -0.67 51 99 0.13 7 09S -0.75 51 100 0.24 11 08S 0.41 51 101 0.20 10 08S 0.44 51 104 0.14 7 08S 0.41 51 111 0.41 18 12S -0.87 51 112 0.23 11 10S -0.77 51 112 0.26 12 14S 0.20 52 16 0.21 11 08S -0.36 52 18 0.20 10 08S -0.54 52 104 0.22 11 08S 0.47 52 107 0.17 8 08S 0.41 to 1CAN031703 Page 25 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 52 113 0.26 12 09S 0.36 52 114 0.34 16 10S -0.75 52 118 0.26 13 10S -0.75 53 1 0.30 13 13S -0.61 53 8 0.28 14 10S 0.25 53 19 0.21 11 08S -0.60 53 20 0.15 8 08S 0.56 53 20 0.26 13 08S -0.61 53 22 0.43 19 08S -0.63 53 23 0.26 14 08S -0.59 53 24 0.34 16 08S -0.63 53 26 0.24 12 08S -0.61 53 98 0.22 10 08S 0.41 53 116 0.23 11 14S 0.16 53 121 0.27 13 12S 0.34 53 122 0.08 4 14S 0.23 53 123 0.24 11 14S 0.23 54 11 0.21 12 09S 0.53 54 19 0.17 10 08S 0.55 54 20 0.31 15 08S -0.61 54 21 0.15 9 08S 0.55 54 21 0.21 12 08S -0.59 54 22 0.25 12 08S -0.61 54 23 0.30 16 08S -0.64 54 24 0.19 10 08S -0.56 54 25 0.27 14 08S -0.64 54 26 0.27 13 08S -0.63 54 27 0.18 10 08S -0.64 54 28 0.24 12 08S -0.63 54 31 0.20 11 08S -0.63 54 95 0.12 6 06S -0.69 54 96 0.26 12 08S 0.39 to 1CAN031703 Page 26 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 54 106 0.14 7 08S 0.43 54 109 0.14 7 08S -0.71 54 109 0.20 10 08S 0.40 54 116 0.22 10 10S -0.77 54 119 0.32 15 10S -0.78 54 121 0.21 10 11S 0.29 54 123 0.15 8 12S -0.82 54 124 0.20 10 12S -0.86 55 8 0.15 9 09S 0.60 55 19 0.28 13 08S -0.61 55 22 0.19 10 08S -0.60 55 23 0.50 21 08S -0.59 55 24 0.24 12 08S -0.62 55 26 0.25 13 08S -0.64 55 27 0.23 11 08S -0.65 55 28 0.22 12 08S -0.64 55 94 0.26 12 08S 0.41 55 95 0.22 11 08S 0.40 55 99 0.16 9 08S 0.40 55 101 0.19 10 08S 0.42 55 101 0.24 12 08S -0.76 55 102 0.22 10 08S 0.39 55 103 0.20 10 08S 0.42 55 104 0.12 6 08S -0.75 55 118 0.26 12 11S 0.27 55 119 0.37 17 11S 0.29 55 121 0.25 12 11S 0.31 55 121 0.28 14 10S -0.78 55 121 0.35 16 12S 0.33 55 122 0.21 10 09S 0.41 55 122 0.32 14 11S 0.32 55 122 0.43 18 09S -0.73 to 1CAN031703 Page 27 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 56 7 0.12 7 09S -0.56 56 7 0.18 10 10S 0.58 56 19 0.10 6 08S 0.55 56 19 0.18 10 08S -0.62 56 20 0.18 9 08S 0.54 56 20 0.31 14 08S -0.59 56 21 0.23 12 08S -0.60 56 23 0.31 16 08S -0.60 56 26 0.24 11 08S -0.63 56 27 0.18 10 08S -0.64 56 28 0.21 10 08S -0.61 56 102 0.27 13 08S 0.40 56 118 0.20 10 09S 0.36 56 118 0.24 12 11S -0.87 56 119 0.24 15 10S -0.77 56 120 0.32 15 12S 0.20 56 121 0.22 14 09S -0.75 56 122 0.21 11 11S 0.22 56 122 0.29 14 09S -0.73 56 123 0.20 13 10S -0.79 56 123 0.26 16 12S 0.34 56 127 0.24 10 12S -0.84 57 21 0.12 7 08S 0.53 57 21 0.34 17 08S -0.60 57 22 0.26 12 08S -0.59 57 25 0.18 10 08S -0.66 57 27 0.23 12 08S -0.62 57 30 0.21 10 08S -0.60 57 105 0.19 10 08S -0.69 57 107 0.12 6 09S -0.76 57 107 0.12 6 10S -0.82 57 109 0.11 6 08S 0.47 to 1CAN031703 Page 28 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 57 125 0.22 11 12S -0.85 58 20 0.12 6 08S 0.52 58 21 0.11 6 08S 0.57 58 21 0.23 12 08S -0.57 58 22 0.26 12 08S -0.59 58 23 0.28 14 08S -0.60 58 24 0.14 7 08S 0.61 58 24 0.22 11 08S -0.58 58 25 0.21 11 08S 0.57 58 25 0.22 12 08S -0.64 58 29 0.18 10 08S -0.68 58 33 0.21 11 08S -0.68 58 104 0.15 11 07S 0.43 58 125 0.21 11 12S -0.85 59 20 0.25 12 08S -0.61 59 21 0.11 6 08S 0.55 59 29 0.28 14 08S -0.66 59 95 0.19 10 08S 0.40 59 105 0.13 7 08S -0.76 59 106 0.13 9 08S -0.74 59 124 0.31 19 11S 0.2 59 126 0.09 7 12S -0.83 60 21 0.12 7 08S 0.57 60 21 0.27 14 08S -0.59 60 22 0.25 12 08S -0.58 60 23 0.19 10 08S -0.61 60 24 0.33 15 08S -0.56 60 103 0.21 11 08S 0.42 60 108 0.26 17 08S 0.43 60 124 0.37 21 11S 0.31 60 125 0.16 8 12S -0.85 61 21 0.09 5 08S 0.56 to 1CAN031703 Page 29 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 61 21 0.23 11 08S -0.52 61 22 0.13 7 08S 0.53 61 22 0.27 14 08S -0.64 61 23 0.35 16 08S -0.61 61 100 0.17 12 08S 0.47 61 101 0.33 15 08S 0.40 61 124 0.17 12 12S -0.88 61 125 0.08 4 10S 0.29 61 125 0.33 15 11S 0.34 62 19 0.23 11 08S -0.61 62 22 0.19 10 08S -0.61 62 26 0.16 9 08S 0.54 62 26 0.19 10 08S -0.61 62 98 0.25 16 08S -0.74 62 98 0.26 16 08S 0.41 62 99 0.19 10 08S 0.40 62 100 0.14 10 08S -0.72 62 107 0.21 11 08S 0.40 62 122 0.20 13 14S 0.23 62 122 0.26 16 09S 0.38 63 19 0.30 14 08S -0.60 63 21 0.20 10 08S -0.63 63 22 0.08 5 08S 0.57 63 22 0.31 16 08S -0.61 63 23 0.26 12 08S -0.60 63 25 0.22 11 08S -0.65 63 26 0.17 10 08S -0.65 63 27 0.23 11 08S -0.60 63 110 0.15 10 08S 0.38 63 111 0.22 11 08S 0.44 64 20 0.19 10 08S -0.60 64 22 0.20 10 08S -0.62 to 1CAN031703 Page 30 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 64 24 0.31 14 08S -0.65 64 25 0.32 17 08S -0.65 64 27 0.16 10 08S -0.65 64 100 0.13 6 07S 0.46 64 103 0.19 11 08S 0.36 64 103 0.25 14 10S -0.82 64 104 0.11 5 08S -0.74 64 104 0.32 13 08S 0.39 64 105 0.18 11 08S -0.73 64 106 0.16 7 08S 0.42 64 106 0.19 8 06S 0.44 64 124 0.19 11 14S 0.22 64 126 0.20 12 14S 0.25 65 20 0.27 13 08S -0.62 65 21 0.41 18 08S -0.57 65 23 0.30 14 08S -0.66 65 24 0.24 12 08S -0.62 65 26 0.42 20 08S -0.65 65 27 0.13 7 08S 0.53 65 28 0.29 15 08S -0.67 65 32 0.24 13 08S -0.67 65 103 0.18 8 06S -0.70 65 107 0.38 15 10S -0.81 65 107 0.37 15 10S 0.24 65 110 0.18 9 09S -0.71 65 110 0.24 11 07S 0.39 65 110 0.23 11 10S 0.28 65 125 0.20 12 10S 0.27 66 20 0.27 13 08S -0.62 66 21 0.16 8 08S -0.49 66 22 0.35 16 08S -0.62 66 23 0.25 12 08S -0.64 to 1CAN031703 Page 31 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 66 24 0.29 14 08S -0.66 66 26 0.58 23 08S -0.67 66 27 0.26 14 08S -0.65 66 28 0.31 14 08S -0.67 66 106 0.23 10 08S -0.74 66 108 0.19 8 08S 0.42 66 123 0.17 8 10S 0.34 66 124 0.20 12 11S 0.31 67 2 0.29 13 13S 0.58 67 20 0.23 11 08S -0.56 67 21 0.24 12 08S -0.62 67 22 0.30 14 08S -0.60 67 23 0.37 17 08S -0.62 67 24 0.35 16 08S -0.62 67 25 0.27 13 08S -0.68 67 26 0.44 19 08S -0.60 67 27 0.27 15 08S -0.67 67 28 0.29 13 08S -0.67 67 29 0.35 18 08S -0.67 67 30 0.35 16 08S -0.64 67 102 0.16 9 07S -0.68 67 105 0.15 7 09S -0.74 67 105 0.18 8 07S 0.46 67 105 0.18 8 10S 0.35 67 124 0.16 9 11S 0.27 67 124 0.26 14 09S 0.36 67 125 0.18 8 09S 0.42 68 18 0.28 13 08S -0.58 68 22 0.30 14 08S -0.60 68 24 0.14 7 08S 0.56 68 24 0.38 17 08S -0.60 68 25 0.27 15 08S -0.63 to 1CAN031703 Page 32 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 68 26 0.30 14 08S -0.69 68 27 0.18 10 08S -0.65 68 28 0.48 20 08S -0.69 68 29 0.25 13 08S -0.65 68 31 0.28 15 08S -0.64 68 32 0.25 12 08S -0.64 68 111 0.14 6 09S -0.78 69 2 0.21 10 11S -0.60 69 4 0.25 11 10S 0.31 69 24 0.25 11 08S -0.62 69 25 0.09 6 08S 0.52 69 26 0.23 11 09S -0.65 69 26 0.32 14 08S -0.69 69 27 0.42 20 08S -0.59 69 28 0.28 13 08S -0.62 69 102 0.16 10 08S -0.75 69 110 0.14 9 10S 0.36 69 126 0.20 12 09S 0.40 69 126 0.40 20 11S 0.29 70 1 0.14 7 11S 0.58 70 3 0.18 11 13S -0.60 70 4 0.23 10 10S 0.29 70 19 0.19 11 08S -0.59 70 20 0.20 9 08S -0.60 70 21 0.22 12 08S -0.65 70 23 0.16 10 08S -0.65 70 25 0.28 15 08S -0.62 70 26 0.22 10 08S -0.60 70 28 0.25 11 08S -0.66 70 103 0.28 12 08S 0.41 70 104 0.14 9 07S 0.44 70 104 0.19 11 06S -0.61 to 1CAN031703 Page 33 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 70 104 0.29 16 09S -0.71 70 106 0.17 10 08S 0.40 70 114 0.09 5 09S -0.77 71 1 0.22 10 11S -0.60 71 5 0.23 13 09S -0.48 71 21 0.11 7 08S 0.52 71 23 0.14 8 08S 0.48 71 23 0.38 19 08S -0.65 71 24 0.41 16 08S -0.64 71 25 0.35 18 08S -0.58 71 26 0.38 16 08S -0.62 71 27 0.26 14 08S -0.68 71 31 0.24 13 08S -0.66 71 32 0.28 12 08S -0.66 71 102 0.25 14 08S 0.49 71 103 0.18 8 08S -0.76 71 104 0.18 8 08S -0.74 71 105 0.13 7 07S 0.46 71 105 0.20 9 10S -0.81 71 105 0.24 11 08S 0.44 71 105 0.28 13 09S -0.75 71 105 0.44 18 06S -0.67 71 107 0.16 9 08S 0.38 71 107 0.28 15 08S -0.77 71 110 0.26 11 08S 0.41 71 112 0.17 10 10S -0.80 71 126 0.19 11 06S -0.69 72 1 0.27 12 13S -0.56 72 22 0.30 13 08S -0.58 72 24 0.25 11 08S -0.60 72 25 0.39 20 08S -0.60 72 26 0.30 13 08S -0.60 to 1CAN031703 Page 34 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 72 27 0.17 10 08S -0.64 72 28 0.25 11 08S -0.67 72 29 0.30 16 08S -0.66 72 31 0.17 10 08S -0.66 72 103 0.15 7 08S 0.44 72 106 0.26 12 08S -0.77 72 107 0.20 12 08S -0.77 72 109 0.16 10 08S 0.42 72 109 0.23 13 10S -0.80 72 111 0.18 11 08S 0.44 72 111 0.23 13 10S -0.78 72 114 0.11 5 08S 0.41 72 124 0.28 10 10S 0.31 72 125 0.31 14 11S 0.26 73 2 0.12 6 11S 0.58 73 10 0.12 5 09S 0.56 73 17 0.23 12 08S -0.58 73 18 0.21 9 08S -0.55 73 19 0.18 10 08S -0.58 73 20 0.29 12 08S -0.60 73 25 0.48 23 08S -0.63 73 27 0.28 15 08S -0.62 73 28 0.28 12 08S -0.67 73 29 0.21 12 08S 0.43 73 104 0.16 6 09S -0.78 73 104 0.28 10 06S -0.68 73 105 0.13 6 08S 0.42 73 107 0.25 11 10S -0.83 73 109 0.25 11 08S -0.74 73 110 0.35 13 09S -0.76 73 115 0.18 9 07S 0.41 73 126 0.09 4 14S 0.20 to 1CAN031703 Page 35 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 73 131 0.21 10 12S 0.33 74 2 0.27 13 13S 0.51 74 6 0.11 6 09S 0.63 74 25 0.27 12 08S -0.67 74 26 0.31 16 08S -0.67 74 27 0.24 11 08S -0.67 74 28 0.17 10 08S -0.69 74 30 0.18 10 08S -0.67 74 39 0.28 12 08S -0.68 74 104 0.12 7 08S -0.75 74 108 0.24 12 08S 0.40 74 108 0.23 12 09S -0.78 74 109 0.21 10 08S 0.42 74 109 0.26 11 07S 0.44 74 109 0.25 11 08S -0.72 74 110 0.15 8 05S -0.66 74 110 0.14 8 07S 0.44 74 110 0.19 10 10S 0.31 74 110 0.22 12 08S 0.36 74 110 0.32 16 10S -0.76 74 110 0.35 17 06S 0.00 74 116 0.14 8 09S -0.76 74 124 0.18 10 11S 0.36 75 6 0.15 7 09S -0.52 75 18 0.25 11 08S -0.59 75 20 0.24 10 08S -0.61 75 21 0.23 12 08S -0.56 75 22 0.16 7 08S -0.59 75 26 0.31 13 08S -0.64 75 27 0.25 14 08S -0.67 75 28 0.25 11 08S -0.64 75 30 0.24 10 08S -0.64 to 1CAN031703 Page 36 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 75 105 0.20 9 07S 0.39 75 105 0.14 11 08S -0.64 75 107 0.22 10 08S 0.41 75 108 0.17 8 08S -0.68 75 108 0.24 11 09S 0.35 75 108 0.25 12 08S 0.35 75 108 0.29 13 09S -0.79 75 108 0.45 19 06S -0.69 75 109 0.14 7 07S 0.44 75 109 0.21 10 08S 0.42 75 109 0.51 20 06S 0.41 75 111 0.26 11 08S 0.35 75 112 0.07 4 06S -0.64 75 113 0.27 12 06S -0.69 76 5 0.09 5 09S 0.56 76 15 0.13 6 09S 0.54 76 17 0.10 5 08S 0.50 76 19 0.09 5 08S 0.54 76 20 0.25 11 08S -0.54 76 22 0.26 11 08S -0.58 76 23 0.13 6 09S -0.66 76 23 0.13 7 08S 0.48 76 23 0.24 11 08S -0.66 76 26 0.22 10 08S -0.60 76 27 0.11 6 08S 0.50 76 27 0.21 10 08S -0.66 76 28 0.28 12 08S -0.67 76 41 0.07 4 08S 0.50 76 89 0.09 4 05S 0.52 76 101 0.14 7 08S 0.37 76 102 0.32 16 10S -0.82 76 102 0.38 18 06S -0.70 to 1CAN031703 Page 37 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 76 105 0.15 7 08S -0.65 76 105 0.19 9 09S -0.77 76 106 0.21 11 08S 0.38 76 107 0.11 5 06S 0.44 76 107 0.13 6 08S 0.37 76 108 0.17 9 08S 0.42 76 110 0.19 10 08S 0.45 76 111 0.19 9 08S 0.44 76 122 0.16 9 12S -0.83 76 123 0.31 13 11S 0.29 76 124 0.16 9 12S 0.27 77 2 0.44 19 11S 0.53 77 19 0.15 7 08S 0.58 77 22 0.19 9 08S 0.57 77 23 0.12 6 08S 0.58 77 23 0.26 11 08S -0.60 77 27 0.18 8 08S 0.51 77 28 0.20 10 08S -0.76 77 104 0.16 9 08S 0.40 77 109 0.23 10 09S -0.76 77 109 0.31 13 08S 0.39 77 109 0.33 14 08S -0.74 77 110 0.18 10 08S 0.40 77 112 0.24 13 08S 0.42 77 117 0.13 6 09S -0.77 77 118 0.25 13 10S -0.80 77 132 0.74 24 10S 0.00 78 17 0.24 11 08S -0.52 78 23 0.21 10 08S -0.59 78 103 0.15 7 08S 0.44 78 107 0.28 12 08S -0.74 78 111 0.25 11 08S -0.74 to 1CAN031703 Page 38 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 78 115 0.28 12 07S -0.66 78 125 0.21 10 12S -0.86 78 131 0.21 9 10S -0.79 79 3 0.10 5 13S 0.45 79 19 0.14 6 08S 0.56 79 20 0.24 10 08S -0.63 79 21 0.13 6 08S 0.56 79 23 0.18 8 08S -0.58 79 24 0.31 13 08S -0.63 79 27 0.13 6 08S 0.56 79 28 0.36 14 08S -0.63 79 29 0.29 12 08S -0.65 79 30 0.11 5 08S 0.56 79 110 0.18 10 08S 0.38 79 111 0.26 11 08S 0.42 79 113 0.23 10 08S 0.42 80 5 0.20 9 09S 0.63 80 25 0.23 10 08S -0.60 80 109 0.08 4 08S 0.44 80 110 0.24 12 10S -0.82 80 113 0.14 6 08S 0.37 80 125 0.33 14 11S 0.31 81 1 0.10 5 13S 0.58 81 3 0.11 5 13S 0.54 81 15 0.22 11 08S -0.59 81 17 0.11 6 08S 0.54 81 17 0.24 12 08S -0.58 81 18 0.21 10 08S -0.51 81 23 0.17 9 08S 0.56 81 24 0.27 11 08S -0.60 81 25 0.12 7 08S 0.52 81 26 0.27 11 08S -0.60 to 1CAN031703 Page 39 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 81 36 0.27 11 02S -0.80 81 111 0.16 7 05S -0.65 81 111 0.47 18 06S -0.68 81 114 0.18 10 08S 0.44 81 115 0.27 12 08S 0.42 81 124 0.14 8 09S -0.69 81 126 0.19 10 11S 0.29 81 126 0.20 11 10S -0.76 81 128 0.15 8 12S 0.29 82 18 0.20 10 08S -0.58 82 19 0.29 12 08S -0.56 82 20 0.19 10 08S -0.56 82 22 0.13 6 08S 0.56 82 22 0.25 10 08S -0.60 82 23 0.13 6 08S 0.56 82 24 0.11 6 08S 0.54 82 24 0.31 15 08S -0.60 82 26 0.19 10 08S -0.67 82 34 0.16 7 08S 0.49 82 76 0.17 9 09S 0.59 82 111 0.19 9 08S 0.40 82 113 0.21 9 08S 0.39 82 115 0.11 5 09S -0.77 82 115 0.15 7 08S 0.42 82 117 0.20 9 08S 0.42 83 2 0.13 7 13S 0.56 83 6 0.11 5 10S 0.52 83 10 0.25 11 11S -0.63 83 15 0.19 10 08S -0.54 83 18 0.20 9 08S -0.58 83 19 0.09 5 08S 0.56 83 20 0.35 14 08S -0.61 to 1CAN031703 Page 40 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 83 21 0.14 7 08S 0.56 83 21 0.25 12 08S -0.61 83 23 0.12 7 08S 0.52 83 23 0.49 21 08S -0.70 83 24 0.28 12 08S -0.60 83 25 0.14 7 08S 0.50 83 25 0.25 12 08S -0.70 83 26 0.24 10 08S -0.65 83 28 0.24 10 08S -0.69 83 29 0.12 6 08S 0.47 83 29 0.23 11 08S -0.69 83 112 0.14 5 10S -0.76 83 114 0.13 5 08S 0.42 84 6 0.15 8 09S 0.57 84 15 0.10 5 08S 0.58 84 17 0.11 5 08S 0.54 84 17 0.21 9 08S -0.58 84 18 0.32 15 08S -0.61 84 21 0.11 5 08S 0.54 84 21 0.22 10 08S -0.56 84 22 0.16 8 08S 0.56 84 22 0.40 18 08S -0.62 84 23 0.35 16 08S -0.62 84 24 0.27 11 08S -0.60 84 26 0.30 12 08S -0.65 84 27 0.30 14 08S -0.67 84 29 0.22 11 08S -0.69 84 30 0.23 10 08S -0.67 84 107 0.12 5 08S -0.77 84 111 0.30 13 08S 0.39 84 113 0.18 8 08S 0.44 84 116 0.19 7 08S 0.42 to 1CAN031703 Page 41 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 84 116 0.19 7 09S -0.73 84 125 0.22 10 10S -0.74 84 125 0.26 11 09S 0.37 85 6 0.14 7 09S 0.54 85 6 0.16 8 09S -0.52 85 17 0.09 6 08S 0.59 85 19 0.11 6 08S 0.55 85 21 0.27 13 08S -0.67 85 23 0.12 7 08S 0.54 85 23 0.19 10 08S -0.67 85 24 0.21 11 08S -0.69 85 25 0.25 12 08S -0.67 85 27 0.18 8 08S 0.54 85 29 0.26 11 08S -0.67 85 97 0.20 9 07S 0.52 85 109 0.24 10 08S -0.75 85 112 0.16 6 08S 0.40 85 123 0.22 10 10S -0.77 85 123 0.30 13 10S 0.29 85 124 0.34 12 11S 0.29 86 6 0.11 6 09S 0.54 86 18 0.11 6 08S 0.54 86 22 0.16 8 08S 0.54 86 23 0.26 13 08S -0.69 86 24 0.24 12 08S -0.71 86 78 0.23 9 09S 0.56 86 112 0.18 7 08S 0.44 86 114 0.16 6 08S 0.42 87 5 0.10 5 09S 0.59 87 16 0.09 5 08S 0.53 87 18 0.11 5 08S 0.47 87 20 0.26 13 08S -0.63 to 1CAN031703 Page 42 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 87 21 0.25 12 08S -0.65 87 22 0.22 11 08S -0.65 87 27 0.12 6 08S 0.50 87 37 0.10 5 07S 0.54 87 113 0.18 7 08S 0.44 87 129 0.21 10 14S -0.90 88 5 0.13 6 09S 0.56 88 15 0.08 5 08S 0.56 88 21 0.09 5 08S 0.56 88 22 0.19 9 08S -0.58 88 23 0.14 7 08S 0.54 88 23 0.26 13 08S -0.61 88 28 0.22 10 08S -0.69 88 111 0.17 9 08S 0.42 88 115 0.13 7 08S 0.40 88 125 0.25 12 12S -0.84 88 127 0.24 12 13S -0.88 89 3 0.10 5 10S 0.11 89 20 0.22 10 08S -0.61 89 21 0.25 12 08S -0.61 89 22 0.19 8 08S 0.54 89 22 0.31 13 08S -0.61 89 23 0.16 9 08S 0.54 89 23 0.23 11 08S -0.65 89 24 0.23 10 08S 0.49 89 25 0.19 10 08S -0.70 89 106 0.25 13 08S 0.42 89 107 0.17 9 09S -0.78 90 3 0.11 5 10S 0.18 90 4 0.12 6 09S 0.52 90 5 0.12 6 09S 0.50 90 20 0.08 5 08S 0.52 to 1CAN031703 Page 43 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 90 22 0.11 6 08S 0.54 90 22 0.21 11 08S -0.67 90 24 0.13 7 08S 0.54 90 24 0.23 11 08S -0.70 90 26 0.13 7 08S 0.47 90 28 0.25 12 08S -0.67 91 19 0.21 11 08S -0.63 91 21 0.27 13 08S -0.65 91 22 0.26 11 08S -0.63 91 23 0.26 13 08S -0.63 91 24 0.35 14 08S -0.63 91 25 0.40 18 08S -0.63 91 106 0.21 11 08S 0.37 91 108 0.18 10 08S 0.42 91 127 0.16 9 10S 0.07 92 4 0.16 8 09S 0.57 92 21 0.29 12 08S -0.65 92 22 0.27 13 08S -0.65 92 23 0.31 13 08S -0.60 92 24 0.32 15 08S -0.63 92 25 0.28 12 08S -0.63 92 26 0.26 13 08S -0.67 92 109 0.09 5 08S 0.44 93 1 0.15 7 13S 0.53 93 22 0.47 20 08S -0.65 93 23 0.35 14 08S -0.63 93 24 0.15 8 08S 0.54 93 24 0.33 15 08S -0.65 93 25 0.24 10 08S -0.65 93 107 0.15 8 08S 0.42 94 1 0.14 7 13S 0.55 94 2 0.15 8 13S 0.56 to 1CAN031703 Page 44 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 94 24 0.37 17 08S -0.63 94 26 0.22 11 08S -0.61 94 28 0.19 10 08S -0.65 94 111 0.23 12 08S 0.44 94 111 0.33 16 07S -0.68 95 3 0.19 9 10S -0.63 95 21 0.25 11 08S -0.63 95 23 0.22 10 08S -0.63 95 25 0.29 12 08S -0.60 95 28 0.20 10 08S -0.69 95 106 0.24 8 07S -0.75 95 109 0.10 5 08S 0.44 95 111 0.21 9 08S 0.42 96 19 0.21 10 08S -0.63 96 23 0.27 12 08S -0.63 96 24 0.27 13 08S -0.70 96 26 0.28 14 08S -0.69 96 107 0.21 9 08S 0.37 97 21 0.26 13 08S -0.67 97 22 0.15 7 08S 0.54 97 22 0.20 9 08S -0.60 97 23 0.25 12 08S -0.65 97 24 0.24 10 08S -0.69 97 25 0.19 10 08S 0.47 97 25 0.21 11 08S -0.67 97 26 0.20 9 08S 0.47 97 26 0.26 11 08S -0.69 97 118 0.10 5 10S 0.31 98 4 0.33 15 09S 0.52 98 5 0.18 8 10S -0.61 98 5 0.23 10 11S -0.59 98 8 0.39 16 09S 0.49 to 1CAN031703 Page 45 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 98 9 0.17 9 09S 0.54 98 22 0.25 11 08S -0.60 98 23 0.19 10 08S -0.67 98 24 0.13 6 08S 0.52 98 24 0.32 13 08S -0.65 98 25 0.20 10 08S -0.63 98 25 0.19 10 08S 0.54 98 26 0.32 13 08S -0.67 98 105 0.15 7 08S 0.46 99 8 0.17 9 09S 0.54 99 9 0.20 9 09S 0.54 99 9 0.23 10 11S -0.63 99 19 0.17 8 08S -0.63 99 20 0.21 10 08S -0.63 99 22 0.23 12 08S -0.65 99 23 0.18 8 08S -0.65 99 23 0.17 8 08S 0.51 99 24 0.39 18 08S -0.69 99 25 0.14 7 08S -0.63 99 25 0.16 7 08S 0.52 99 26 0.34 16 08S -0.67 99 107 0.14 5 08S -0.73 99 107 0.16 5 08S 0.40 99 114 0.12 6 09S -0.61 99 117 0.23 8 09S 0.36 99 118 0.11 5 09S 0.33 99 119 0.18 6 09S 0.40 99 119 0.33 11 07S -0.69 100 1 0.16 7 13S -0.64 100 8 0.14 8 10S -0.59 100 24 0.17 9 08S -0.67 100 25 0.26 11 08S -0.69 to 1CAN031703 Page 46 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 101 1 0.23 10 13S -0.65 101 1 0.24 11 13S 0.47 101 7 0.12 6 10S -0.56 101 23 0.35 15 08S -0.67 101 102 0.20 9 08S 0.42 101 102 0.20 9 08S -0.64 101 111 0.25 8 09S 0.42 101 112 0.11 4 10S -0.07 102 5 0.13 6 10S -0.61 102 9 0.19 10 09S 0.52 103 5 0.20 9 10S -0.67 103 9 0.28 12 09S -0.57 103 9 0.28 12 09S 0.5 103 19 0.17 7 08S -0.67 103 20 0.07 4 08S 0.47 103 29 0.51 21 08S -0.67 103 103 0.13 6 08S 0.45 103 113 0.25 11 12S -0.87 104 8 0.20 10 09S -0.59 104 8 0.19 10 09S 0.52 104 9 0.21 9 09S -0.58 104 23 0.16 8 08S -0.62 104 25 0.17 9 08S -0.64 104 27 0.21 11 08S -0.69 104 29 0.21 11 08S -0.67 104 30 0.27 11 08S -0.69 104 31 0.20 10 08S -0.69 104 34 0.28 12 08S -0.67 105 7 0.13 6 09S 0.52 105 8 0.15 8 09S 0.50 105 8 0.18 9 09S -0.59 105 24 0.20 9 08S -0.67 to 1CAN031703 Page 47 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 105 25 0.19 10 08S -0.69 105 28 0.18 8 08S -0.65 105 29 0.20 10 08S -0.69 105 35 0.22 11 08S -0.67 106 5 0.31 13 10S 0.45 106 17 0.14 6 08S -0.65 106 20 0.21 11 09S 0.47 106 23 0.20 10 08S 0.45 106 23 0.26 13 08S -0.69 106 24 0.13 6 08S -0.67 106 25 0.28 14 08S -0.67 106 27 0.09 5 08S 0.47 106 27 0.27 13 08S -0.67 106 29 0.33 15 08S -0.67 106 31 0.49 21 08S -0.69 106 32 0.23 10 08S -0.69 106 33 0.20 10 08S -0.71 106 87 0.22 9 08S -0.71 106 98 0.20 10 08S -0.73 106 112 0.09 4 10S -0.80 106 119 0.64 22 10S -0.76 107 3 0.19 8 10S 0.27 107 5 0.17 7 09S 0.49 107 6 0.36 16 09S -0.65 107 17 0.19 10 08S -0.61 107 22 0.16 7 08S -0.67 107 26 0.35 14 08S -0.67 107 27 0.20 10 08S -0.67 107 29 0.19 10 08S 0.45 107 29 0.35 16 08S -0.69 107 30 0.29 12 08S -0.69 107 82 0.25 11 08S -0.71 to 1CAN031703 Page 48 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 107 88 0.29 12 08S 0.42 107 93 0.18 9 08S -0.71 107 112 0.22 10 10S -0.78 107 113 0.10 5 10S -0.82 107 114 0.21 9 10S -0.76 107 115 0.15 8 10S -0.77 108 5 0.24 10 09S -0.63 108 21 0.21 9 08S -0.65 108 25 0.23 10 08S -0.67 108 26 0.36 16 08S -0.65 108 28 0.22 11 08S 0.43 108 28 0.67 25 08S -0.70 108 30 0.47 20 08S -0.69 108 31 0.28 12 08S -0.71 108 109 0.26 13 10S -0.79 109 4 0.23 10 09S -0.54 109 18 0.15 8 10S -0.69 109 20 0.27 13 08S -0.65 109 24 0.34 15 08S -0.67 109 25 0.22 10 08S -0.65 109 27 0.23 10 08S 0.47 109 27 0.30 13 08S -0.71 109 29 0.31 13 08S -0.69 109 32 0.32 15 08S -0.69 109 90 0.14 7 08S -0.73 110 15 0.25 12 09S 0.47 110 21 0.22 11 08S -0.67 110 25 0.24 12 08S -0.67 110 26 0.20 9 08S -0.69 110 27 0.09 5 08S 0.47 110 28 0.24 10 08S -0.71 110 29 0.17 9 08S 0.47 to 1CAN031703 Page 49 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 110 29 0.23 11 08S -0.67 110 30 0.21 9 08S -0.71 110 31 0.27 13 08S -0.71 110 80 0.27 13 08S 0.44 110 83 0.27 11 08S -0.67 110 86 0.19 10 06S 0.42 111 15 0.18 8 09S 0.49 111 20 0.28 13 08S -0.65 111 24 0.19 9 08S 0.47 111 24 0.23 11 10S -0.72 111 25 0.24 10 08S -0.69 111 26 0.15 8 08S -0.67 111 27 0.12 6 09S -0.65 111 27 0.26 11 08S -0.69 111 29 0.18 8 08S 0.49 111 29 0.56 21 08S -0.69 111 30 0.35 16 08S -0.69 111 31 0.22 10 08S -0.69 111 32 0.20 10 08S -0.67 111 34 0.27 13 08S -0.69 111 35 0.22 10 08S -0.71 111 82 0.17 9 08S -0.73 111 89 0.27 13 08S 0.38 112 23 0.11 5 08S 0.49 112 27 0.17 8 08S 0.51 112 27 0.26 11 08S -0.67 112 29 0.24 10 08S -0.64 112 30 0.14 7 08S 0.45 112 30 0.26 12 08S -0.69 112 31 0.27 12 08S -0.69 112 32 0.28 13 08S -0.71 112 33 0.22 10 08S -0.73 to 1CAN031703 Page 50 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 112 34 0.26 12 08S -0.71 112 88 0.23 11 08S 0.38 112 95 0.24 12 08S 0.42 112 98 0.14 7 08S 0.44 113 3 0.28 13 10S -0.63 113 5 0.13 6 09S 0.52 113 24 0.14 7 08S -0.64 113 26 0.22 10 08S -0.69 113 27 0.10 5 08S 0.49 113 28 0.26 11 08S -0.71 113 30 0.42 17 08S -0.71 113 31 0.14 7 08S 0.47 113 37 0.24 11 08S -0.71 113 83 0.09 5 08S -0.74 113 88 0.15 8 08S -0.71 113 110 0.16 8 10S -0.78 113 113 0.25 13 13S -0.90 114 3 0.41 16 13S 0.52 114 4 0.18 9 10S -0.58 114 30 0.16 8 08S -0.67 114 31 0.26 11 08S -0.69 114 35 0.27 11 08S -0.67 114 36 0.35 15 08S -0.71 114 108 0.16 8 10S -0.76 114 109 0.18 9 10S -0.77 115 4 0.35 15 10S -0.65 115 27 0.19 8 08S 0.47 115 27 0.28 12 08S -0.62 115 29 0.46 17 08S -0.71 115 70 0.17 9 08S -0.74 115 71 0.25 12 08S -0.73 115 108 0.14 7 10S -0.77 to 1CAN031703 Page 51 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 115 109 0.18 10 10S 0.11 115 110 0.25 12 10S 0.11 116 5 0.61 24 09S 0.44 116 6 0.12 5 09S 0.49 116 26 0.15 6 08S 0.47 116 26 0.17 7 08S -0.69 116 28 0.31 13 08S -0.69 116 33 0.21 10 08S -0.71 116 40 0.42 16 08S -0.69 116 77 0.20 10 08S -0.73 116 79 0.16 8 08S -0.73 116 86 0.16 8 08S 0.43 116 87 0.10 5 08S 0.44 116 107 0.11 6 10S -0.13 116 109 0.13 7 10S 0.07 117 6 0.14 7 09S 0.54 117 7 0.12 5 09S 0.49 117 22 0.12 6 08S 0.47 117 28 0.18 8 08S -0.67 117 29 0.11 8 08S -0.61 117 37 0.16 7 08S 0.45 117 59 0.16 8 08S -0.74 117 62 0.25 12 08S -0.71 117 67 0.21 11 08S -0.74 117 68 0.13 7 08S -0.75 117 107 0.28 13 10S 0.09 118 36 0.27 12 08S -0.69 118 68 0.31 15 08S -0.73 118 76 0.13 7 09S -0.75 118 83 0.11 6 08S 0.45 118 105 0.10 5 14S 0.20 118 106 0.07 4 10S 0.09 to 1CAN031703 Page 52 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 119 6 0.24 10 09S 0.52 119 25 0.15 7 08S -0.65 119 27 0.13 6 08S -0.67 119 30 0.15 7 09S -0.69 119 30 0.32 14 08S -0.71 119 31 0.26 11 08S -0.67 119 34 0.15 7 08S -0.69 119 44 0.11 5 08S -0.68 119 44 0.33 14 07S 0.40 119 56 0.33 14 08S -0.72 119 57 0.24 11 08S -0.72 119 58 0.24 10 08S -0.71 119 59 0.23 11 08S -0.69 119 60 0.30 12 08S -0.71 119 67 0.29 13 08S -0.71 119 69 0.31 14 08S -0.69 119 70 0.16 7 08S 0.42 119 101 0.11 5 10S -0.77 119 104 0.09 5 10S 0.17 120 4 0.57 22 10S -0.67 120 5 0.23 11 10S -0.67 120 7 0.13 6 09S 0.52 120 22 0.23 11 09S 0.40 120 24 0.12 6 08S -0.67 120 40 0.26 12 08S -0.75 120 58 0.24 11 08S -0.72 120 62 0.18 9 08S -0.74 120 64 0.27 12 08S -0.69 120 66 0.20 10 08S -0.74 120 76 0.15 7 08S -0.73 120 78 0.19 9 08S -0.75 120 78 0.24 11 08S 0.40 to 1CAN031703 Page 53 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 120 80 0.21 10 08S 0.42 120 98 0.11 6 10S -0.80 120 99 0.16 7 12S -0.84 120 101 0.24 10 10S 0.15 120 102 0.17 9 10S 0.04 121 8 0.32 17 09S 0.47 121 26 0.11 5 08S -0.69 121 30 0.17 8 08S 0.42 121 31 0.19 11 08S -0.69 121 33 0.20 11 08S -0.69 121 54 0.29 15 08S -0.73 121 56 0.29 14 08S -0.74 121 59 0.16 7 08S -0.75 121 65 0.20 8 08S -0.75 121 76 0.15 8 08S 0.42 121 80 0.13 7 08S 0.47 121 100 0.18 10 10S -0.72 121 101 0.11 7 10S 0.11 121 102 0.16 9 10S 0.09 122 1 0.25 12 10S 0.51 122 7 0.32 17 10S -0.65 122 8 0.19 11 09S 0.49 122 34 0.12 7 07S 0.44 122 34 0.19 11 08S 0.42 122 34 0.21 12 08S -0.69 122 35 0.25 11 08S -0.73 122 39 0.16 10 08S -0.74 122 40 0.42 16 09S -0.71 122 50 0.27 14 08S -0.75 122 52 0.34 17 08S -0.77 122 61 0.31 12 08S -0.73 122 62 0.16 8 08S -0.74 to 1CAN031703 Page 54 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 122 63 0.11 5 08S 0.44 122 63 0.16 7 08S -0.73 122 72 0.16 8 07S -0.69 123 7 0.18 8 10S -0.65 123 8 0.11 7 09S 0.52 123 18 0.17 10 09S 0.45 123 28 0.13 8 08S -0.70 123 29 0.12 6 08S -0.69 123 36 0.28 15 09S -0.71 123 37 0.35 14 09S -0.69 123 38 0.18 10 08S 0.45 123 41 0.18 10 08S -0.75 123 51 0.19 11 08S -0.73 123 54 0.29 12 08S -0.73 123 60 0.20 8 08S -0.71 123 65 0.15 8 08S 0.47 123 71 0.19 10 08S 0.45 123 74 0.14 6 08S 0.46 123 99 0.14 8 10S 0.13 124 4 0.25 14 13S 0.43 124 8 0.16 9 09S 0.52 124 9 0.26 11 09S 0.42 124 14 0.29 15 10S -0.65 124 28 0.15 7 08S -0.64 124 30 0.12 5 08S -0.69 124 31 0.15 9 08S -0.69 124 32 0.19 9 08S -0.71 124 35 0.18 10 09S -0.69 124 36 0.11 5 08S -0.71 124 38 0.14 6 08S -0.69 124 38 0.17 8 08S 0.44 124 39 0.16 10 09S -0.74 to 1CAN031703 Page 55 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 124 42 0.08 4 08S -0.67 124 48 0.25 14 08S -0.73 124 49 0.35 18 08S -0.73 124 55 0.20 10 08S 0.43 124 76 0.16 7 08S -0.73 125 1 0.13 7 13S 0.49 125 7 0.21 12 10S -0.63 125 8 0.10 5 09S 0.47 125 9 0.14 6 09S 0.47 125 13 0.22 10 10S -0.62 125 17 0.29 15 10S -0.67 125 27 0.31 16 10S -0.72 125 28 0.23 10 08S 0.46 125 39 0.20 11 09S -0.71 125 44 0.17 10 08S -0.75 125 45 0.14 6 08S -0.73 125 46 0.18 10 08S -0.75 125 48 0.22 12 08S -0.75 125 51 0.23 10 09S -0.73 125 53 0.10 5 08S -0.66 125 54 0.13 6 06S 0.47 125 54 0.17 8 08S -0.65 125 54 0.17 8 09S -0.71 125 56 0.15 7 08S 0.45 125 58 0.09 4 08S -0.69 125 64 0.23 10 08S 0.47 125 65 0.26 11 08S 0.42 125 73 0.14 6 08S 0.44 125 93 0.30 13 10S -0.75 126 7 0.21 12 10S -0.63 126 21 0.17 10 10S -0.74 126 24 0.46 18 10S -0.71 to 1CAN031703 Page 56 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 126 32 0.22 9 08S -0.69 126 40 0.14 6 08S -0.73 126 42 0.28 12 08S -0.73 126 46 0.14 7 08S 0.42 126 47 0.24 13 08S -0.73 126 48 0.25 11 09S -0.71 126 50 0.23 10 08S -0.71 126 54 0.08 4 08S -0.73 126 55 0.17 8 08S -0.71 126 57 0.14 7 08S -0.73 127 40 0.17 10 09S -0.67 127 41 0.29 12 08S 0.38 127 47 0.22 10 09S 0.42 127 50 0.15 9 08S -0.73 127 64 0.19 9 08S 0.45 127 88 0.22 10 09S 0.39 127 89 0.14 6 10S -0.77 127 91 0.14 7 10S -0.71 127 98 0.41 17 13S -0.85 128 1 0.2 10 14S -0.65 128 1 0.34 15 13S 0.44 128 2 0.15 8 14S 0.54 128 2 0.26 12 12S -0.65 128 36 0.33 14 10S -0.78 128 48 0.12 5 08S -0.75 128 83 0.32 14 09S 0.37 128 84 0.20 9 09S 0.41 128 88 0.20 9 10S 0.04 129 9 0.51 22 09S 0.38 129 10 0.13 7 14S 0.43 129 15 0.18 10 10S 0.45 129 21 0.26 14 10S -0.67 to 1CAN031703 Page 57 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 129 22 0.18 11 10S -0.71 129 33 0.25 13 10S -0.78 129 40 0.09 4 08S -0.69 130 2 0.22 9 13S 0.44 130 8 0.18 10 10S -0.65 130 9 0.27 14 09S 0.45 130 10 0.26 11 09S 0.42 130 33 0.06 3 08S -0.66 130 34 0.10 6 08S -0.68 130 37 0.06 3 08S -0.69 130 39 0.09 4 08S -0.73 130 45 0.24 10 08S -0.73 130 49 0.16 8 08S -0.71 130 51 0.14 7 08S -0.69 130 85 0.37 15 11S 0.36 131 1 0.15 7 14S -0.62 131 7 0.16 7 10S -0.67 131 8 0.24 13 09S 0.45 131 9 0.10 4 09S 0.49 131 36 0.06 4 08S -0.73 131 83 0.23 10 11S 0.38 131 84 0.36 15 10S 0.04 131 85 0.09 5 10S 0.04 132 7 0.18 8 10S -0.65 132 8 0.41 19 09S 0.45 132 9 0.23 10 09S 0.45 132 19 0.23 10 10S -0.71 132 30 0.06 4 08S -0.67 132 38 0.06 4 08S -0.67 132 46 0.14 8 08S 0.47 133 1 0.13 6 13S 0.44 133 2 0.17 7 13S 0.46 to 1CAN031703 Page 58 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 133 2 0.14 8 14S -0.55 133 9 0.17 9 09S 0.49 133 10 0.19 8 09S 0.47 133 37 0.08 5 08S -0.71 133 81 0.37 15 11S 0.40 133 83 0.25 11 13S -0.85 133 87 0.22 11 13S -0.85 134 1 0.27 11 14S -0.63 134 2 0.27 11 10S -0.67 134 6 0.20 11 10S -0.63 134 7 0.38 15 10S -0.69 134 8 0.22 12 10S -0.63 134 9 0.34 14 09S 0.47 134 9 0.42 16 10S -0.67 134 79 0.46 17 11S 0.37 135 1 0.14 6 14S -0.65 135 1 0.24 10 13S 0.44 135 8 0.27 11 10S -0.64 135 9 0.22 11 09S 0.45 135 9 0.37 17 10S -0.63 135 10 0.33 13 10S -0.67 135 78 0.29 12 11S 0.38 136 6 0.29 14 10S -0.67 136 7 0.17 7 13S -0.69 136 7 0.24 10 10S -0.65 136 8 0.14 8 09S 0.47 136 9 0.26 11 09S 0.49 136 9 0.51 18 10S -0.65 136 67 0.20 10 09S 0.37 136 76 0.28 12 11S 0.37 136 77 0.23 12 11S 0.41 137 8 0.20 10 09S 0.40 to 1CAN031703 Page 59 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 137 12 0.13 7 09S 0.45 137 75 0.20 10 10S 0.38 138 7 0.16 7 10S -0.69 138 13 0.11 5 09S 0.44 138 15 0.31 12 10S -0.69 138 17 0.26 11 10S -0.71 138 19 0.35 13 10S -0.69 138 62 0.19 10 11S 0.33 138 64 0.23 12 11S 0.42 138 74 0.13 7 12S -0.81 139 10 0.20 10 10S -0.67 139 11 0.36 14 10S -0.67 139 12 0.34 16 10S -0.67 139 13 0.26 11 10S -0.69 139 14 0.35 17 10S -0.65 139 15 0.37 14 10S -0.71 139 16 0.42 19 10S -0.67 139 57 0.16 7 09S -0.66 139 62 0.26 13 11S 0.37 139 63 0.28 12 11S 0.38 139 65 0.25 10 11S 0.38 140 1 0.16 8 13S -0.70 140 7 0.44 16 10S -0.69 140 9 0.70 26 10S -0.70 140 11 0.26 13 10S -0.69 140 13 0.08 4 14S -0.69 140 13 0.28 14 10S -0.69 140 14 0.80 28 10S -0.67 140 15 0.43 19 10S -0.73 140 16 0.11 6 09S -0.67 140 16 0.58 24 09S 0.36 140 57 0.23 10 13S -0.87 to 1CAN031703 Page 60 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 140 58 0.18 10 11S 0.42 140 60 0.35 16 11S 0.42 140 61 0.34 13 11S 0.40 140 62 0.32 15 11S -0.81 140 66 0.18 9 10S 0.37 141 9 0.11 6 10S -0.69 141 10 0.20 8 10S -0.69 141 11 0.72 27 10S -0.72 141 14 0.25 10 09S 0.35 141 14 0.30 12 10S -0.62 141 15 0.25 13 09S 0.36 141 16 0.13 6 09S 0.42 141 16 0.18 8 10S -0.69 141 56 0.19 10 11S 0.35 141 59 0.31 12 11S 0.38 141 60 0.81 30 11S 0.39 141 62 0.20 10 11S -0.76 142 11 0.17 9 10S -0.69 142 12 0.61 24 10S -0.70 142 13 1.71 41 10S 0.00 142 14 0.24 13 10S -0.74 142 51 0.55 23 11S 0.37 142 53 0.53 22 11S 0.42 142 57 0.31 15 11S 0.44 142 60 0.21 10 11S 0.42 142 62 0.15 8 11S 0.46 143 1 0.31 14 14S -0.65 143 10 0.23 12 10S -0.67 143 12 0.25 13 10S -0.60 143 41 0.19 8 09S 0.42 143 52 0.46 20 11S 0.37 143 53 0.43 16 11S 0.38 to 1CAN031703 Page 61 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 143 55 0.15 8 10S 0.39 143 58 0.30 12 11S -0.74 143 60 0.24 10 11S -0.72 144 7 0.29 12 10S -0.69 144 8 0.13 8 10S -0.71 144 9 0.55 20 10S -0.71 144 13 0.26 14 10S 0.42 144 18 0.28 12 09S 0.38 144 20 0.24 10 09S 0.42 144 21 0.22 12 09S 0.42 144 35 0.21 9 09S 0.35 144 41 0.21 9 09S 0.42 144 46 0.34 14 11S 0.40 144 47 0.28 11 11S 0.40 145 3 0.24 10 11S -0.72 145 3 0.26 11 13S -0.72 145 3 0.32 13 13S 0.39 145 4 0.20 10 10S -0.72 145 7 0.18 10 10S -0.71 145 11 0.33 16 10S -0.74 145 19 0.24 13 09S 0.42 145 32 0.14 6 09S 0.44 145 36 0.22 9 11S 0.38 145 37 0.38 15 11S 0.35 145 44 0.19 8 11S 0.42 145 46 0.09 5 10S 0.00 145 47 0.17 9 11S 0.42 146 5 0.18 8 13S -0.76 146 10 0.51 21 10S -0.72 146 15 0.46 19 10S -0.74 146 16 0.19 8 10S -0.73 146 34 0.18 8 10S 0.02 to 1CAN031703 Page 62 of 62 ROW COL VOLTS %TW TSP Elevation (Inches) 146 36 0.22 9 11S 0.38 146 36 0.27 11 13S -0.87 146 43 0.13 7 10S -0.72 146 46 0.24 10 13S -0.81 146 47 0.16 7 10S -0.78 147 5 0.30 12 10S -0.71 147 6 0.31 16 10S -0.69 147 7 0.54 22 10S -0.69 147 8 0.92 32 10S -0.69 147 10 0.16 9 10S -0.69 147 13 0.27 11 10S -0.69 147 15 0.25 10 10S -0.75 147 16 0.13 7 10S -0.76 147 29 0.11 5 10S 0.04 147 29 0.20 9 11S 0.40 147 30 0.17 8 11S 0.38 148 11 0.26 11 10S -0.73 148 13 0.48 20 10S -0.71 148 14 0.17 8 10S -0.73 148 22 0.26 11 10S 0.38 148 23 0.15 7 10S 0.38 148 25 0.15 7 10S 0.13 149 4 0.21 10 11S -0.69 149 32 0.18 8 10S 0.39 150 4 0.34 14 11S -0.71 150 14 0.22 9 10S -0.75 151 19 0.18 9 10S -0.71 151 23 0.14 7 13S 0.26

Attachment 4 SG B TSP Wear Indications to 1CAN031703 Page 1 of 60 Attachment 4 SG B TSP Wear Indications ROW COL VOLTS %TW TSP Elevation (Inches) 1 1 0.20 9 11S -0.71 1 4 0.97 32 11S -0.73 1 8 0.50 21 11S -0.71 1 10 0.29 14 11S -0.76 1 14 0.45 20 11S -0.74 1 15 0.30 14 11S -0.76 1 16 0.77 27 11S -0.74 1 17 0.36 16 11S -0.74 1 18 0.38 16 11S -0.74 1 19 0.19 9 11S -0.71 1 20 0.50 21 11S -0.72 1 24 0.26 13 11S -0.72 2 1 0.18 9 11S -0.71 2 2 0.12 7 14S -0.81 2 2 0.29 14 10S 0.44 2 2 0.29 14 11S 0.44 2 4 0.56 23 11S -0.73 2 5 0.72 26 11S -0.73 2 6 0.14 8 10S -0.73 2 6 0.40 18 11S -0.71 2 7 1.05 34 11S -0.71 2 8 0.41 18 11S -0.69 2 9 0.52 21 11S -0.71 2 10 0.52 22 11S -0.71 2 16 0.17 9 11S -0.73 2 17 0.36 16 11S -0.71 2 18 0.24 12 11S -0.74 2 19 0.22 10 11S -0.71 2 20 0.50 20 11S -0.72 2 21 1.27 38 11S -0.74 to 1CAN031703 Page 2 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 2 23 0.62 24 11S -0.74 2 24 0.40 18 11S -0.74 2 25 0.22 10 11S -0.74 2 26 0.27 13 11S -0.72 2 27 0.32 15 11S -0.72 2 28 0.27 13 11S -0.72 2 31 0.13 7 12S -0.76 3 1 0.52 21 11S -0.71 3 1 0.16 8 11S 0.44 3 2 0.28 14 10S -0.71 3 2 0.87 31 11S -0.62 3 2 0.13 7 10S 0.46 3 3 0.42 18 11S -0.74 3 3 0.17 8 10S 0.48 3 4 0.33 15 11S -0.71 3 4 0.22 11 10S 0.44 3 5 0.45 22 11S -0.70 3 5 0.40 20 10S -0.67 3 5 0.15 9 10S 0.45 3 6 0.75 27 11S -0.74 3 6 0.18 9 11S 0.44 3 7 0.31 15 11S -0.71 3 8 0.32 17 11S -0.70 3 8 0.42 21 10S -0.70 3 8 0.15 9 08S -0.65 3 9 0.28 15 14S -0.76 3 9 0.28 15 12S 0.29 3 9 0.22 13 14S 0.36 3 9 0.18 10 11S 0.41 3 9 0.22 13 10S 0.41 3 10 0.33 17 11S -0.72 3 10 0.35 18 10S -0.70 to 1CAN031703 Page 3 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 3 11 0.13 6 12S -0.78 3 11 0.14 6 08S 0.45 3 12 0.12 8 10S -0.72 3 12 0.19 11 12S -0.72 3 12 0.33 17 12S 0.00 3 21 0.25 11 12S 0.29 3 32 0.21 10 11S -0.70 3 34 0.17 8 10S 0.51 3 35 0.13 7 10S 0.51 4 1 0.26 12 11S -0.71 4 1 0.11 6 10S 0.51 4 2 0.38 17 11S -0.74 4 2 0.25 12 10S -0.71 4 2 0.10 5 10S 0.44 4 3 0.28 13 11S -0.69 4 4 0.25 12 11S -0.71 4 5 0.59 23 11S -0.71 4 6 0.61 22 11S -0.74 4 7 0.42 17 11S -0.72 4 7 0.30 13 12S 0.00 4 8 0.39 17 12S 0.00 4 10 0.27 13 10S -0.71 4 10 0.64 24 12S 0.00 4 10 0.29 13 11S 0.35 4 12 0.18 11 10S -0.67 4 12 0.18 10 12S 0.27 4 27 0.19 11 12S 0.29 4 36 0.21 11 11S -0.72 4 37 0.26 12 11S -0.67 4 37 0.49 20 10S 0.42 4 37 0.23 11 11S 0.46 5 2 0.31 15 11S -0.69 to 1CAN031703 Page 4 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 5 3 0.17 8 10S 0.46 5 4 0.31 15 11S -0.73 5 5 0.36 19 11S -0.72 5 8 0.46 18 12S 0.00 5 9 0.17 10 10S -0.67 5 9 0.18 10 11S 0.43 5 10 0.23 10 11S 0.43 5 11 0.53 25 10S -0.70 5 11 0.33 17 12S 0.00 5 11 0.30 16 11S 0.40 5 12 0.21 10 14S -0.81 5 12 0.37 16 10S -0.69 5 12 0.51 21 12S 0.00 5 12 0.23 11 11S 0.32 5 13 0.22 13 14S -0.83 5 13 0.21 12 11S 0.38 5 14 0.24 10 11S 0.40 5 23 0.26 14 10S -0.72 5 24 0.16 10 12S 0.34 5 26 0.19 11 10S 0.09 5 27 0.20 9 10S 0.09 5 29 0.25 11 11S 0.40 5 31 0.24 11 11S 0.40 5 34 0.25 14 11S 0.36 5 37 0.20 9 11S 0.47 5 39 0.19 9 13S -0.79 5 39 0.23 11 11S -0.69 5 39 0.23 11 12S 0.37 5 39 0.20 10 11S 0.49 5 40 0.28 14 11S -0.69 5 41 0.36 16 11S -0.72 5 41 0.29 13 11S 0.23 to 1CAN031703 Page 5 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 5 42 0.20 10 11S -0.69 5 42 0.23 11 11S 0.49 5 42 0.21 11 10S 0.53 6 2 0.79 29 11S -0.69 6 3 0.10 5 10S 0.48 6 4 0.37 17 10S -0.72 6 4 0.17 9 10S 0.46 6 5 0.32 14 11S -0.69 6 6 0.17 10 10S -0.65 6 7 0.33 14 10S -0.69 6 8 0.36 18 10S -0.69 6 21 0.43 17 10S -0.74 6 23 0.24 10 10S -0.76 6 24 0.38 19 10S -0.67 6 24 0.22 13 11S 0.38 6 25 0.25 11 10S -0.72 6 30 0.21 9 10S 0.09 6 37 0.23 13 12S 0.32 6 37 0.38 19 11S 0.34 6 38 0.28 12 11S 0.40 6 39 0.29 16 11S -0.72 6 39 0.50 24 11S 0.43 6 40 0.28 12 11S 0.40 6 43 0.14 7 10S 0.46 6 44 0.43 19 11S -0.72 6 44 0.30 14 11S 0.46 6 44 0.23 11 10S 0.48 6 45 0.23 11 11S -0.72 6 45 0.21 10 12S 0.30 6 46 0.22 11 11S -0.71 6 46 0.41 18 11S 0.46 6 47 0.38 17 10S 0.49 to 1CAN031703 Page 6 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 7 1 0.24 11 11S -0.69 7 2 0.43 19 11S -0.71 7 8 0.46 22 10S -0.69 7 9 0.81 27 10S -0.71 7 10 0.69 28 10S -0.71 7 11 0.58 22 10S -0.69 7 12 0.38 19 10S -0.71 7 15 0.37 15 10S -0.70 7 36 0.23 13 11S 0.40 7 39 0.79 28 11S 0.30 7 40 0.32 13 11S 0.38 7 40 0.16 7 10S 0.45 7 41 0.17 10 11S 0.40 7 47 0.18 8 11S 0.49 7 47 0.25 11 10S 0.49 7 48 0.33 13 11S -0.70 7 48 0.29 11 10S 0.46 7 49 0.13 6 12S 0.35 7 49 0.36 14 11S 0.46 7 49 0.23 10 10S 0.51 7 50 0.23 10 10S 0.51 8 1 0.33 15 11S -0.73 8 1 0.21 10 10S 0.48 8 2 0.25 12 11S -0.71 8 4 0.39 18 11S -0.72 8 4 0.12 6 10S 0.46 8 5 0.55 22 10S -0.69 8 6 0.46 18 10S -0.69 8 7 0.27 12 11S -0.74 8 7 0.47 20 10S -0.69 8 7 0.20 10 11S 0.46 8 8 0.24 13 11S -0.74 to 1CAN031703 Page 7 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 8 8 0.47 22 11S 0.43 8 10 0.73 30 10S -0.71 8 11 0.85 28 10S -0.71 8 12 0.38 19 10S -0.71 8 12 0.18 10 10S 0.42 8 13 0.22 10 10S -0.71 8 38 0.25 14 10S 0.36 8 39 0.19 9 13S 0.32 8 39 0.27 12 10S 0.38 8 40 0.24 14 09S -0.67 8 43 0.10 5 13S -0.81 8 47 0.23 10 11S 0.43 8 50 0.20 8 10S 0.49 8 51 0.20 9 11S -0.70 8 51 0.51 19 10S 0.49 8 52 0.28 11 11S -0.69 8 53 0.16 7 11S -0.69 8 53 0.17 7 10S 0.53 8 54 0.27 11 12S -0.74 8 54 0.16 7 10S 0.53 9 1 0.19 9 10S 0.46 9 3 0.30 14 11S -0.71 9 4 0.19 10 11S -0.72 9 4 0.38 17 10S -0.69 9 5 0.39 17 10S -0.69 9 7 0.25 13 10S -0.67 9 9 0.33 17 11S -0.74 9 9 0.31 16 10S -0.69 9 11 0.23 13 11S -0.76 9 11 0.34 17 11S 0.38 9 12 0.28 12 10S -0.69 9 13 0.30 16 10S -0.69 to 1CAN031703 Page 8 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 9 14 0.16 8 10S 0.40 9 15 0.21 12 10S 0.42 9 28 0.18 9 10S 0.38 9 37 0.22 10 10S 0.36 9 41 0.29 12 14S -0.86 9 52 0.27 15 13S -0.70 9 53 0.21 9 13S -0.74 9 54 0.11 7 10S 0.49 9 55 0.51 18 11S 0.39 9 55 0.21 9 10S 0.51 9 56 0.30 12 12S -0.72 9 56 0.22 9 12S 0.42 9 56 0.20 9 10S 0.53 9 57 0.37 14 11S 0.44 9 58 0.81 26 10S 0.51 9 59 0.44 16 11S -0.71 9 59 0.14 6 11S 0.46 9 59 0.19 8 10S 0.53 9 60 0.34 14 12S -0.74 9 60 0.44 17 10S 0.51 10 2 0.25 11 11S -0.70 10 2 0.20 10 10S 0.43 10 3 0.27 12 11S -0.70 10 4 0.40 17 11S -0.69 10 4 0.25 12 10S 0.44 10 7 0.13 8 10S -0.67 10 9 0.44 19 10S -0.72 10 11 0.25 11 11S -0.76 10 11 0.22 10 11S 0.42 10 15 0.17 10 14S -0.83 10 16 0.23 10 10S -0.71 10 17 0.22 12 10S 0.38 to 1CAN031703 Page 9 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 10 29 0.16 9 08S -0.69 10 33 0.26 13 10S 0.38 10 44 0.27 15 14S 0.25 10 45 0.12 6 14S 0.29 10 54 0.23 13 11S 0.43 10 56 0.31 17 11S -0.72 10 56 0.12 8 10S 0.47 10 57 0.16 7 10S 0.47 10 58 0.20 12 11S -0.70 10 59 0.25 11 13S -0.74 10 59 0.19 9 10S 0.52 10 60 0.20 8 13S 0.28 10 61 0.27 11 11S -0.72 10 61 0.16 7 12S 0.37 10 62 0.24 10 11S 0.46 10 64 0.22 9 11S -0.69 10 65 0.29 12 10S 0.51 11 2 0.24 11 11S -0.75 11 2 0.22 10 11S 0.38 11 3 0.22 10 11S -0.74 11 7 0.33 14 10S -0.69 11 8 0.54 22 10S -0.69 11 9 0.49 21 10S -0.71 11 10 0.22 12 10S -0.67 11 13 0.23 10 10S -0.69 11 14 1.02 33 10S -0.69 11 17 0.21 10 10S -0.75 11 31 0.17 8 14S -0.78 11 34 0.15 8 10S 0.36 11 35 0.23 11 10S 0.37 11 36 0.18 10 10S 0.36 11 46 0.10 5 13S -0.81 to 1CAN031703 Page 10 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 11 49 0.17 10 14S -0.79 11 55 0.19 11 13S -0.75 11 58 0.19 8 10S 0.45 11 60 0.14 7 10S 0.45 11 61 0.13 8 10S 0.52 11 62 0.18 8 10S 0.47 11 63 0.27 15 11S -0.72 11 64 0.14 6 08S -0.67 11 64 0.17 7 11S 0.44 11 66 0.22 9 11S -0.69 12 1 0.18 9 11S -0.70 12 1 0.15 7 10S 0.41 12 2 0.32 14 11S -0.72 12 2 0.14 7 10S 0.41 12 6 0.21 11 10S -0.67 12 7 0.43 17 10S -0.67 12 9 0.30 13 10S -0.69 12 10 0.33 17 10S -0.70 12 11 0.55 21 10S -0.71 12 12 0.62 24 10S -0.71 12 13 0.43 19 10S -0.69 12 18 0.23 10 10S 0.40 12 24 0.22 10 14S 0.27 12 35 0.20 11 10S 0.33 12 38 0.20 13 14S 0.23 12 40 0.15 10 14S 0.25 12 57 0.15 7 10S 0.45 12 64 0.16 11 10S 0.49 12 65 0.16 7 10S 0.54 12 66 0.23 10 11S -0.71 12 67 0.43 17 11S -0.74 12 67 0.28 12 11S 0.44 to 1CAN031703 Page 11 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 12 68 0.28 11 11S -0.67 12 69 0.21 9 10S 0.51 13 3 0.24 11 11S -0.63 13 6 0.39 16 10S -0.69 13 7 0.31 16 10S -0.67 13 10 0.11 5 14S -0.83 13 13 0.22 12 10S 0.40 13 15 1.01 36 10S -0.67 13 16 1.25 36 10S -0.71 13 17 0.15 9 11S -0.81 13 18 0.15 7 10S -0.73 13 56 0.14 10 14S 0.29 13 60 0.22 14 10S 0.45 13 62 0.14 9 10S 0.45 13 68 0.13 9 10S 0.49 13 69 0.12 6 13S 0.31 13 72 0.54 20 11S -0.67 13 74 0.55 20 10S -0.71 13 74 0.23 10 10S 0.44 14 7 0.45 21 10S -0.67 14 8 0.36 15 10S -0.71 14 19 0.18 10 10S -0.74 14 24 0.29 12 14S 0.22 14 25 0.18 10 14S 0.25 14 38 0.19 9 14S 0.18 14 42 0.17 11 14S 0.23 14 62 0.26 16 10S 0.43 14 68 0.15 10 10S 0.45 14 69 0.12 6 10S 0.47 14 70 0.18 12 11S -0.72 14 70 0.33 19 11S 0.42 14 75 0.42 16 11S -0.72 to 1CAN031703 Page 12 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 14 75 0.71 24 11S 0.49 14 76 0.72 24 11S -0.71 14 77 0.21 9 10S 0.46 15 3 0.21 10 11S -0.70 15 5 0.16 9 10S 0.43 15 7 1.11 35 10S -0.72 15 8 0.31 16 10S -0.70 15 24 0.19 11 10S 0.36 15 25 0.24 11 14S 0.20 15 25 0.11 5 10S 0.35 15 30 0.15 8 14S -0.89 15 32 0.21 11 14S -0.87 15 36 0.26 13 14S 0.22 15 63 0.26 11 10S 0.40 15 65 0.29 12 10S 0.40 15 66 0.15 10 10S 0.43 15 67 0.10 5 13S -0.74 15 67 0.24 11 10S 0.40 15 69 0.24 10 10S 0.45 15 72 0.14 9 14S -0.72 15 72 0.18 12 14S 0.38 15 73 0.30 13 09S -0.67 15 77 0.37 14 11S -0.71 15 78 0.16 7 08S -0.69 15 78 0.32 13 11S -0.69 15 79 0.53 19 11S -0.69 15 79 0.32 13 10S 0.46 15 80 0.32 13 11S -0.74 15 80 0.42 16 10S -0.69 16 1 0.24 11 11S -0.75 16 2 0.20 10 11S -0.72 16 8 0.31 16 10S -0.70 to 1CAN031703 Page 13 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 16 28 0.22 10 14S 0.25 16 64 0.15 10 10S 0.40 16 66 0.25 16 10S 0.43 16 67 0.21 9 09S -0.72 16 68 0.12 8 10S 0.47 16 70 0.15 10 13S -0.77 16 70 0.18 12 09S -0.70 16 72 0.34 20 14S -0.81 16 72 0.21 13 09S -0.67 16 75 0.42 17 10S 0.47 16 79 0.82 26 11S -0.69 16 79 0.26 10 11S 0.37 16 80 0.23 10 13S -0.76 16 81 0.24 10 11S -0.72 16 81 0.49 18 10S 0.44 17 1 0.46 19 11S -0.73 17 8 0.28 15 11S 0.43 17 13 0.24 11 10S -0.76 17 28 0.17 10 14S -0.89 17 69 0.16 11 09S -0.70 17 71 0.15 10 09S -0.69 17 79 0.14 10 13S -0.74 17 82 0.49 18 11S -0.74 17 82 0.66 22 10S 0.42 17 84 0.36 14 11S -0.74 17 84 0.27 11 10S -0.69 18 1 0.59 22 11S -0.73 18 8 0.28 15 10S 0.31 18 12 0.19 11 14S 0.29 18 19 0.11 5 14S 0.27 18 54 0.17 11 08S -0.65 18 54 0.12 9 08S 0.43 to 1CAN031703 Page 14 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 18 78 0.17 11 13S -0.74 18 78 0.14 10 09S -0.69 18 78 0.16 10 09S 0.45 18 78 0.38 21 10S 0.45 18 83 0.30 12 11S -0.72 18 83 0.38 15 10S 0.42 18 84 0.41 15 11S -0.70 18 85 0.42 16 10S -0.72 19 1 1.07 33 11S -0.73 19 10 0.14 8 10S 0.38 19 42 0.21 11 08S 0.44 19 49 0.10 7 08S -0.68 19 80 0.35 14 10S 0.47 19 85 0.18 12 12S 0.41 19 87 0.33 13 10S 0.42 20 2 0.38 17 11S -0.77 20 7 0.23 13 10S -0.74 20 9 0.17 10 14S -0.90 20 11 0.19 11 10S 0.36 20 15 0.20 11 10S 0.38 20 29 0.21 12 08S 0.42 20 50 0.16 11 07S -0.67 20 51 0.17 8 09S -0.74 20 51 0.11 5 07S -0.67 20 51 0.15 7 08S -0.63 20 51 0.36 15 08S 0.43 20 54 0.13 9 08S 0.43 20 80 0.13 9 14S 0.36 20 81 0.13 6 14S -0.82 20 81 0.14 6 13S -0.77 20 81 0.16 7 10S 0.45 20 82 0.16 11 10S 0.49 to 1CAN031703 Page 15 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 20 83 0.31 13 11S 0.36 20 84 0.14 10 13S -0.74 20 84 0.18 12 13S 0.31 21 2 0.29 13 11S -0.77 21 7 1.00 31 10S -0.71 21 8 0.21 12 10S -0.72 21 33 0.14 6 08S 0.44 21 42 0.14 8 08S 0.45 21 47 0.16 8 08S 0.46 21 48 0.15 7 08S 0.45 21 57 0.16 7 08S 0.42 21 58 0.17 11 08S 0.45 21 60 0.13 9 07S 0.43 21 82 0.21 14 10S 0.42 21 83 0.19 9 10S 0.47 21 84 0.15 10 04S -0.60 21 89 0.21 9 10S -0.72 22 2 0.22 11 12S -0.80 22 3 0.60 23 11S -0.73 22 11 0.19 11 10S 0.38 22 12 0.15 7 10S 0.38 22 36 0.21 9 08S -0.67 22 36 0.16 8 08S 0.42 22 38 0.13 6 07S 0.42 22 38 0.12 6 08S 0.44 22 41 0.11 6 08S -0.73 22 41 0.17 9 06S -0.64 22 41 0.26 13 08S 0.45 22 56 0.13 9 07S 0.58 22 57 0.20 9 08S 0.45 22 58 0.17 11 08S 0.43 22 60 0.14 10 08S 0.47 to 1CAN031703 Page 16 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 22 62 0.13 9 08S 0.45 22 63 0.11 5 08S 0.45 22 66 0.21 14 08S 0.47 22 93 0.25 11 11S -0.72 22 93 0.20 9 10S -0.70 23 2 0.32 14 11S -0.77 23 5 0.12 6 10S -0.76 23 8 1.07 33 10S -0.73 23 19 0.42 20 14S -0.92 23 38 0.14 6 08S 0.38 23 45 0.39 18 08S 0.42 23 51 0.16 9 08S 0.47 23 56 0.13 6 08S 0.40 23 59 0.17 9 08S 0.45 23 85 0.23 12 09S -0.65 23 92 0.28 11 12S 0.35 24 1 0.37 16 11S -0.76 24 2 0.25 12 11S -0.75 24 5 0.24 11 10S -0.74 24 10 0.22 12 10S -0.74 24 11 0.11 5 10S 0.36 24 41 0.21 10 08S 0.44 24 43 0.23 11 08S 0.44 24 44 0.29 15 08S 0.42 24 45 0.15 7 08S -0.62 24 45 0.36 16 08S 0.42 24 49 0.11 6 08S -0.72 24 49 0.20 11 08S 0.43 24 51 0.19 10 08S 0.45 24 84 0.25 13 13S -0.72 24 84 0.27 14 11S 0.34 25 1 0.61 23 10S -0.74 to 1CAN031703 Page 17 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 25 2 0.26 12 10S -0.78 25 3 0.30 13 11S -0.76 25 4 0.28 15 11S -0.74 25 7 0.64 23 10S -0.74 25 31 0.17 8 08S 0.47 25 33 0.20 9 08S 0.44 25 34 0.19 11 08S 0.44 25 35 0.13 6 08S 0.47 25 36 0.26 14 08S 0.42 25 41 0.08 4 08S -0.73 25 44 0.16 9 07S 0.45 25 52 0.29 15 08S 0.43 25 53 0.20 8 07S 0.42 25 53 0.18 8 08S 0.43 25 55 0.12 5 08S 0.47 25 72 0.14 8 08S 0.45 25 84 0.16 7 13S -0.81 25 96 0.16 7 10S 0.51 26 4 0.31 16 11S -0.76 26 8 0.17 10 10S -0.77 26 13 0.18 8 10S 0.34 26 15 0.25 11 14S 0.20 26 24 0.18 11 10S 0.38 26 28 0.15 9 08S 0.43 26 31 0.15 7 08S 0.44 26 33 0.13 6 08S 0.42 26 34 0.12 7 08S 0.45 26 36 0.12 8 08S 0.42 26 39 0.22 10 06S 0.47 26 45 0.13 6 08S 0.49 26 45 0.15 7 07S 0.57 26 46 0.14 8 07S 0.40 to 1CAN031703 Page 18 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 26 46 0.21 11 08S 0.45 26 91 0.20 10 10S 0.43 26 92 0.23 9 10S 0.45 27 2 1.16 36 11S -0.75 27 4 0.17 10 11S -0.79 27 13 0.26 15 14S -0.88 27 19 0.15 9 10S 0.36 27 27 0.15 9 08S 0.45 27 30 0.18 8 08S 0.44 27 34 0.12 6 07S 0.42 27 48 0.12 6 07S 0.44 27 48 0.19 9 08S 0.44 27 56 0.26 10 08S 0.43 27 67 0.21 11 08S 0.45 27 68 0.08 4 08S 0.49 28 2 0.27 13 11S -0.78 28 3 0.27 12 11S -0.82 28 4 0.16 10 11S -0.86 28 42 0.15 10 08S 0.47 28 49 0.18 9 08S 0.44 28 61 0.20 10 08S 0.43 28 62 0.16 7 08S 0.47 28 66 0.17 7 08S 0.47 28 67 0.14 8 08S 0.45 28 68 0.12 5 08S 0.47 28 78 0.17 7 08S 0.45 28 82 0.15 6 08S 0.52 29 2 0.27 12 11S -0.69 29 3 0.17 10 11S -0.79 29 3 0.18 11 11S 0.41 29 31 0.16 10 08S 0.40 29 33 0.15 9 08S 0.45 to 1CAN031703 Page 19 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 30 14 0.21 12 14S -0.90 30 32 0.13 8 08S 0.40 30 33 0.16 7 08S 0.42 30 34 0.10 6 08S 0.45 30 36 0.18 11 08S 0.45 30 76 0.20 10 08S 0.45 30 77 0.11 5 07S 0.45 30 77 0.16 7 08S 0.45 30 79 0.13 5 08S 0.47 30 82 0.21 11 08S 0.43 30 102 0.18 10 13S -0.77 30 102 0.27 13 04S -0.67 30 103 0.38 14 12S -0.74 31 2 0.22 11 10S -0.75 31 2 0.25 12 11S -0.75 31 2 0.23 12 11S 0.37 31 23 0.12 8 08S 0.40 31 33 0.13 8 10S -0.74 31 33 0.37 19 08S 0.40 31 34 0.29 13 08S 0.42 31 36 0.09 4 10S -0.78 31 36 0.28 12 08S 0.42 31 37 0.18 11 06S -0.62 31 37 0.31 17 08S 0.42 31 73 0.20 9 08S 0.45 31 77 0.18 8 08S -0.72 31 77 0.20 9 08S 0.45 31 77 0.12 6 07S 0.47 31 78 0.24 14 08S 0.43 31 79 0.21 10 08S 0.40 31 98 0.15 8 08S -0.65 31 100 0.20 10 10S 0.43 to 1CAN031703 Page 20 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 32 1 0.57 23 11S -0.73 32 13 0.27 15 14S -0.92 32 30 0.27 15 08S 0.43 32 32 0.11 7 08S -0.72 32 32 0.16 10 08S 0.45 32 34 0.21 12 10S 0.36 32 36 0.17 10 08S 0.42 32 77 0.17 8 08S 0.43 32 100 0.19 9 10S 0.43 32 103 0.20 12 12S 0.41 33 1 0.68 24 11S -0.79 33 2 0.49 21 11S -0.73 33 28 0.13 6 08S 0.40 33 52 0.17 8 08S 0.44 33 79 0.22 11 08S 0.42 33 87 0.17 8 08S 0.51 33 88 0.11 5 07S 0.47 33 89 0.16 8 08S 0.42 34 1 0.33 15 11S -0.73 34 2 0.37 16 11S -0.78 34 3 0.32 14 11S -0.75 34 85 0.12 6 08S 0.44 34 90 0.13 6 08S 0.47 35 2 0.41 18 11S -0.73 35 89 0.14 7 08S 0.49 35 107 0.22 11 13S -0.71 36 37 0.09 4 07S 0.59 36 38 0.10 6 08S 0.40 36 40 0.11 7 08S 0.42 36 90 0.17 8 08S -0.67 36 97 0.11 6 08S 0.49 36 108 0.22 11 09S -0.67 to 1CAN031703 Page 21 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 36 110 0.35 15 12S 0.38 37 10 0.33 14 14S 0.22 37 24 0.12 6 08S 0.42 37 27 0.13 8 08S 0.45 37 31 0.16 9 09S 0.42 37 31 0.23 13 08S 0.45 37 83 0.10 5 08S 0.45 37 91 0.10 5 08S 0.49 37 93 0.16 8 08S -0.62 37 110 0.15 7 10S 0.45 37 112 0.20 10 13S -0.71 37 114 0.12 5 11S -0.67 38 1 0.22 11 10S 0.46 38 38 0.12 8 08S 0.47 38 39 0.10 5 08S 0.46 38 69 0.20 9 04S 0.56 38 110 0.21 10 13S -0.70 38 111 0.24 11 10S 0.47 38 115 0.12 5 10S -0.53 39 25 0.12 7 08S 0.45 39 27 0.15 9 08S 0.42 39 28 0.08 4 08S 0.42 39 28 0.09 4 07S 0.44 39 114 0.25 12 12S 0.42 40 1 0.20 10 11S -0.73 40 31 0.09 6 08S 0.45 40 93 0.11 6 08S -0.69 41 22 0.12 6 08S 0.42 41 25 0.12 8 08S -0.72 41 111 0.30 14 13S -0.74 41 113 0.12 6 10S 0.54 41 114 0.17 8 11S -0.65 to 1CAN031703 Page 22 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 41 114 0.15 7 14S -0.60 41 115 0.32 12 13S -0.70 42 2 0.25 12 11S -0.76 42 24 0.13 6 08S 0.40 42 25 0.08 5 08S 0.49 42 112 0.24 10 13S -0.72 43 100 0.15 7 08S 0.49 43 114 0.15 8 09S 0.49 44 1 0.15 7 10S 0.43 44 3 0.21 10 10S 0.11 44 4 0.21 12 10S 0.18 44 25 0.07 4 08S 0.47 44 100 0.15 8 08S 0.49 44 113 0.26 11 09S -0.65 44 116 0.43 16 13S -0.67 44 117 0.27 11 11S -0.65 45 5 0.23 13 10S 0.09 45 29 0.07 5 08S 0.47 45 101 0.07 3 08S 0.51 45 109 0.08 4 08S 0.49 45 113 0.29 13 09S -0.54 45 113 0.11 5 09S 0.54 45 114 0.24 11 13S -0.67 45 114 0.30 14 09S -0.65 45 115 0.13 6 10S 0.54 45 116 0.15 8 10S 0.51 46 2 0.16 8 10S 0.46 46 6 0.22 13 10S 0.09 46 103 0.09 5 08S 0.51 46 103 0.12 6 07S 0.55 46 114 0.19 8 14S -0.63 46 115 0.16 8 10S 0.56 to 1CAN031703 Page 23 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 46 116 0.20 9 10S 0.58 46 119 0.19 8 11S -0.65 46 119 0.52 19 13S 0.00 47 2 0.14 7 10S 0.44 47 7 0.29 16 10S 0.14 47 111 0.38 16 09S -0.61 47 114 0.22 11 10S 0.51 47 117 0.19 8 13S -0.67 48 1 0.27 14 11S 0.43 48 20 0.08 4 09S -0.71 48 38 0.08 4 08S 0.47 48 113 0.29 13 09S -0.60 48 114 0.30 14 09S -0.67 48 115 0.15 7 14S 0.47 48 115 0.14 7 10S 0.49 48 116 0.24 11 13S -0.67 48 121 0.29 12 12S -0.69 48 121 0.49 18 13S -0.60 48 121 0.21 9 11S 0.58 49 1 0.26 13 11S -0.75 49 2 0.20 11 11S 0.39 49 7 0.09 6 13S 0.25 49 8 0.23 12 10S 0.11 49 20 0.08 4 08S 0.42 49 85 0.14 7 06S 0.51 49 102 0.12 6 08S 0.49 49 113 0.25 11 09S -0.67 49 113 0.15 7 09S 0.45 49 115 0.18 8 13S -0.68 49 115 0.14 6 10S 0.52 49 122 0.29 12 13S -0.65 50 1 0.33 16 11S -0.75 to 1CAN031703 Page 24 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 50 8 0.09 5 13S 0.22 50 20 0.09 5 08S 0.38 50 105 0.14 6 08S 0.51 50 113 0.23 10 09S -0.65 50 114 0.18 9 10S 0.54 50 116 0.15 8 10S 0.56 51 120 0.17 8 10S 0.65 52 4 0.25 14 10S -0.70 52 4 0.14 9 13S 0.27 52 114 0.17 8 13S -0.72 52 120 0.10 5 13S -0.61 52 121 0.25 12 13S -0.58 52 121 0.21 10 10S 0.67 53 1 0.12 7 06S 0.49 53 3 0.23 11 14S -0.91 53 104 0.12 6 08S 0.51 53 116 0.32 14 13S -0.72 53 117 0.26 11 13S -0.67 53 117 0.21 9 10S 0.52 53 118 0.28 13 13S -0.65 53 118 0.34 15 10S 0.53 53 119 0.32 13 10S 0.52 53 120 0.11 6 14S -0.56 53 120 0.25 12 10S 0.56 53 121 0.43 17 10S 0.56 53 122 0.24 11 10S 0.69 53 124 0.25 12 13S -0.65 53 124 0.10 5 10S 0.67 54 1 0.26 13 14S -0.80 54 22 0.12 6 08S 0.43 54 23 0.18 9 08S 0.43 54 118 0.32 14 13S -0.67 to 1CAN031703 Page 25 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 54 119 0.26 11 09S -0.65 54 119 0.13 6 10S 0.54 54 120 0.22 11 09S -0.63 54 120 0.15 7 10S 0.56 54 121 0.23 10 09S -0.65 54 122 0.16 8 10S 0.56 54 123 0.35 14 13S -0.63 54 123 0.19 8 11S 0.56 54 123 0.18 8 10S 0.58 54 124 0.30 13 12S -0.65 54 124 0.41 17 13S -0.62 54 124 0.34 15 12S 0.49 54 125 0.18 9 12S 0.44 55 4 0.12 6 13S -0.79 55 26 0.15 7 08S 0.40 55 116 0.18 9 13S -0.60 55 120 0.10 5 09S 0.57 55 124 0.19 9 09S 0.53 55 125 0.34 15 12S 0.44 55 125 0.30 14 10S 0.67 56 25 0.11 5 08S 0.43 56 112 0.13 6 08S 0.56 56 125 0.24 11 12S -0.64 56 125 0.14 7 10S 0.61 56 126 0.23 11 10S 0.60 56 127 0.19 9 12S -0.65 57 17 0.13 7 08S 0.41 57 20 0.15 7 08S 0.43 57 22 0.13 6 08S 0.43 57 124 0.21 10 09S -0.62 57 126 0.28 13 12S 0.47 57 126 0.11 6 10S 0.68 to 1CAN031703 Page 26 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 57 127 0.18 9 10S 0.67 58 18 0.06 3 09S -0.70 58 108 0.10 5 09S 0.48 58 126 0.26 11 13S -0.63 58 126 0.15 7 11S 0.58 58 127 0.10 5 10S 0.67 58 129 0.15 7 12S -0.53 59 124 0.25 11 09S 0.54 59 125 0.15 7 11S 0.63 59 126 0.13 6 10S 0.63 59 127 0.19 9 10S 0.62 59 128 0.23 11 13S -0.67 60 19 0.17 9 08S 0.38 60 124 0.26 12 09S -0.58 60 125 0.21 9 09S 0.52 60 125 0.17 8 10S 0.54 60 125 0.30 12 14S 0.54 60 125 0.13 6 11S 0.56 60 127 0.16 7 10S 0.61 61 1 0.32 16 11S -0.76 61 122 0.16 8 13S -0.67 61 125 0.11 5 14S -0.54 61 125 0.21 9 09S 0.56 61 126 0.15 7 10S 0.58 61 127 0.15 7 10S 0.63 61 128 0.24 11 13S -0.60 61 129 0.14 7 12S -0.65 61 129 0.08 4 11S -0.51 61 130 0.16 8 10S 0.65 62 5 0.14 8 14S -0.79 62 110 0.11 6 08S 0.56 62 124 0.11 5 10S 0.56 to 1CAN031703 Page 27 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 63 4 0.72 29 11S 0.39 63 125 0.22 10 09S -0.55 63 125 0.28 13 09S 0.57 63 126 0.15 7 10S 0.65 63 128 0.32 14 13S -0.60 63 128 0.26 12 12S 0.51 63 129 0.22 11 12S 0.51 64 111 0.19 10 09S -0.66 64 123 0.19 10 10S -0.64 64 124 0.14 7 09S 0.58 64 125 0.23 11 10S 0.60 64 129 0.26 12 10S 0.60 65 110 0.19 10 09S -0.61 65 110 0.21 11 09S 0.48 65 110 0.18 9 10S 0.50 65 114 0.13 6 08S 0.56 65 118 0.22 10 09S 0.54 65 128 0.10 6 12S 0.54 66 37 0.11 6 08S 0.49 66 109 0.14 8 08S 0.57 66 119 0.13 6 09S 0.54 67 5 0.21 11 10S 0.20 67 6 0.12 5 13S -0.81 67 125 0.11 5 09S -0.54 67 129 0.12 6 10S 0.60 67 130 0.21 10 13S -0.62 67 130 0.25 12 13S 0.51 67 130 0.19 9 12S 0.60 68 7 0.34 14 14S 0.25 68 110 0.17 8 08S 0.56 68 111 0.11 6 08S 0.55 68 113 0.11 6 08S 0.57 to 1CAN031703 Page 28 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 68 114 0.12 5 08S 0.56 68 117 0.11 6 09S 0.53 68 124 0.12 5 09S 0.56 68 126 0.16 7 09S -0.51 68 126 0.12 5 09S 0.54 68 130 0.17 8 12S 0.53 68 131 0.20 10 10S -0.60 68 131 0.39 17 13S 0.51 68 131 0.19 9 10S 0.60 69 4 0.25 11 11S 0.41 69 8 0.36 15 14S -0.91 69 114 0.14 7 08S 0.60 69 128 0.17 9 13S -0.61 69 130 0.22 11 12S 0.49 69 131 0.24 11 13S 0.49 69 131 0.25 12 12S 0.51 70 6 0.19 10 13S 0.27 70 20 0.10 5 08S 0.45 70 114 0.09 4 08S 0.58 70 124 0.22 11 09S -0.59 70 124 0.13 7 09S 0.50 70 130 0.17 8 12S 0.51 70 131 0.11 6 09S -0.53 71 1 0.16 9 12S -0.82 71 5 0.19 10 10S 0.09 71 116 0.10 5 08S 0.62 71 121 0.13 6 09S 0.53 71 132 0.20 9 10S -0.62 72 128 0.14 6 12S 0.52 72 129 0.19 10 12S -0.57 72 129 0.28 13 12S 0.51 72 130 0.38 16 12S 0.46 to 1CAN031703 Page 29 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 72 130 0.20 10 11S 0.48 72 131 0.24 11 10S -0.60 72 131 0.09 5 09S -0.48 72 131 0.26 12 11S 0.62 72 131 0.25 12 12S 0.67 73 7 0.26 13 14S -0.88 73 108 0.16 7 08S 0.45 73 120 0.18 8 09S 0.58 73 125 0.26 12 09S -0.57 73 126 0.28 13 09S -0.54 73 127 0.19 8 09S -0.58 73 131 0.23 11 09S -0.58 73 131 0.22 10 12S 0.51 73 131 0.27 12 13S 0.55 73 132 0.67 25 10S -0.58 73 132 0.09 5 08S -0.55 73 132 0.13 7 08S 0.58 73 132 0.13 7 12S 0.58 74 114 0.18 8 08S 0.60 74 117 0.31 13 09S -0.60 74 124 0.14 7 13S -0.53 74 125 0.24 12 09S -0.63 74 127 0.20 10 13S -0.58 74 127 0.18 9 12S 0.51 74 128 0.16 7 09S -0.49 74 130 0.26 12 10S 0.55 74 131 0.22 10 11S -0.62 74 131 0.30 14 13S 0.53 74 131 0.24 11 12S 0.60 75 2 0.19 10 11S -0.75 75 5 0.22 11 10S -0.05 75 125 0.48 20 14S 0.49 to 1CAN031703 Page 30 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 75 126 0.19 10 09S -0.54 75 126 0.09 5 09S 0.61 75 127 0.14 6 13S -0.54 75 129 0.15 7 12S 0.54 75 131 0.24 11 12S 0.51 75 131 0.12 6 11S 0.62 75 132 0.20 10 11S -0.62 75 132 0.35 15 13S 0.55 75 132 0.19 9 12S 0.65 76 1 0.21 11 11S -0.77 76 4 0.08 4 10S 0.02 76 123 0.25 13 09S -0.56 76 123 0.45 20 14S 0.47 76 123 0.15 8 09S 0.59 76 124 0.33 16 09S -0.60 76 124 0.14 8 14S 0.58 77 1 0.49 21 11S -0.80 77 18 0.09 5 08S 0.45 77 118 0.16 9 09S 0.54 77 120 0.13 7 09S 0.56 77 126 0.31 15 09S -0.64 77 126 0.11 6 09S 0.58 77 127 0.23 12 09S -0.47 77 130 0.26 13 11S 0.45 77 131 0.20 10 10S 0.51 77 132 0.11 6 09S -0.55 77 132 0.25 13 12S 0.51 78 1 0.24 12 12S -0.73 78 4 0.14 7 10S 0.07 78 4 0.23 11 12S 0.32 78 114 0.11 7 08S 0.58 78 118 0.13 7 08S 0.60 to 1CAN031703 Page 31 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 78 125 0.18 10 09S -0.59 78 125 0.13 7 09S 0.58 78 126 0.26 13 09S -0.60 78 128 0.20 11 12S 0.51 78 129 0.11 6 06S 0.61 79 1 0.40 19 12S -0.76 79 2 0.29 13 12S -0.81 79 123 0.13 7 09S 0.56 79 126 0.20 11 09S -0.56 79 126 0.14 8 09S 0.63 79 130 0.44 20 11S 0.51 79 131 0.27 13 12S 0.53 79 132 0.21 11 10S 0.51 80 1 0.30 15 11S -0.81 80 1 0.30 15 12S -0.74 80 4 0.22 11 10S 0.02 80 25 0.22 11 09S -0.74 80 114 0.15 8 08S 0.55 80 115 0.14 8 08S 0.62 80 126 0.32 16 09S -0.61 80 130 0.19 10 11S 0.53 81 2 0.22 11 12S -0.79 81 5 0.28 14 10S 0.14 81 6 0.07 4 14S 0.27 81 112 0.27 14 08S 0.59 81 113 0.27 14 07S -0.51 81 113 0.19 10 08S 0.60 81 118 0.25 13 11S -0.68 81 126 0.23 12 09S -0.59 81 126 0.15 8 09S 0.55 81 130 0.18 10 13S -0.60 81 131 0.21 11 12S 0.53 to 1CAN031703 Page 32 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 81 132 0.13 7 09S -0.62 82 1 0.32 15 12S -0.71 82 4 0.26 13 10S 0.05 82 22 0.14 7 08S 0.45 82 112 0.24 13 09S -0.60 82 112 0.18 10 08S 0.56 82 114 0.24 12 09S -0.67 82 114 0.10 6 08S 0.58 82 115 0.19 10 09S -0.60 82 115 0.14 8 08S 0.55 82 116 0.14 8 09S 0.53 82 116 0.19 10 08S 0.56 82 119 0.18 10 09S 0.53 82 120 0.11 6 08S 0.59 82 122 0.16 9 09S 0.55 82 126 0.20 11 09S 0.57 82 131 0.12 7 12S -0.60 83 1 0.24 12 12S -0.78 83 4 0.09 5 10S 0.02 83 5 0.31 15 10S 0.11 83 23 0.17 9 08S 0.45 83 25 0.13 7 08S 0.45 83 116 0.14 8 08S 0.57 83 117 0.19 10 09S 0.51 83 127 0.15 8 09S -0.58 83 128 0.19 10 13S -0.62 84 1 0.29 14 12S -0.76 84 2 0.23 11 12S 0.30 84 4 0.25 13 10S 0.11 84 18 0.13 7 08S -0.78 84 112 0.12 6 08S 0.54 84 115 0.11 6 08S 0.62 to 1CAN031703 Page 33 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 84 117 0.20 11 09S 0.51 84 126 0.20 11 09S 0.55 85 1 0.19 10 08S -0.74 85 29 0.15 8 08S 0.47 85 111 0.14 7 08S 0.59 85 125 0.15 8 09S -0.54 85 125 0.17 9 14S 0.54 85 125 0.12 7 09S 0.56 85 129 0.18 9 09S -0.58 85 129 0.19 10 07S -0.55 86 4 0.26 13 10S 0.11 86 20 0.14 8 08S -0.76 86 20 0.11 6 08S 0.41 86 25 0.25 13 08S 0.43 86 115 0.22 11 09S 0.55 87 3 0.30 15 10S 0.14 87 3 0.28 14 12S 0.34 87 25 0.16 8 08S 0.47 87 28 0.09 5 08S 0.45 87 119 0.15 8 09S 0.54 88 4 0.20 10 10S 0.18 88 110 0.13 7 08S 0.58 88 112 0.13 7 08S 0.54 88 115 0.20 10 09S 0.55 88 116 0.15 8 09S 0.54 89 4 0.13 8 10S 0.14 89 111 0.24 12 14S 0.40 89 111 0.11 6 08S 0.62 89 119 0.50 21 14S -0.69 89 122 0.21 11 09S 0.56 89 126 0.12 6 14S 0.56 90 5 0.19 11 10S 0.05 to 1CAN031703 Page 34 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 90 109 0.10 5 08S 0.61 90 112 0.22 11 09S 0.53 90 116 0.20 10 09S 0.53 90 124 0.16 8 14S 0.62 91 5 0.22 11 12S -0.79 91 110 0.13 7 08S 0.56 91 111 0.21 11 08S 0.55 91 112 0.15 8 08S 0.56 91 116 0.29 14 09S 0.54 91 126 0.09 5 14S 0.56 92 24 0.17 9 08S -0.76 92 109 0.20 10 08S 0.58 92 112 0.20 10 09S 0.53 92 112 0.26 12 08S 0.57 92 116 0.19 10 09S 0.52 92 118 0.15 8 09S 0.53 92 129 0.07 4 12S -0.44 93 4 0.19 10 11S -0.81 93 4 0.33 15 12S -0.77 93 4 0.32 15 12S 0.32 93 21 0.09 6 08S 0.43 93 23 0.10 6 08S 0.43 93 107 0.11 6 08S 0.58 93 108 0.15 8 08S 0.52 93 111 0.13 7 08S 0.58 93 112 0.24 12 09S 0.51 93 125 0.26 13 09S 0.61 93 125 0.12 7 14S 0.63 93 128 0.30 15 12S -0.58 94 11 0.22 12 14S 0.27 94 109 0.21 11 08S 0.58 94 111 0.20 9 08S 0.60 to 1CAN031703 Page 35 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 94 112 0.14 8 08S 0.59 94 114 0.18 10 09S 0.54 94 115 0.19 8 09S 0.53 94 116 0.18 11 09S 0.54 94 121 0.16 10 09S 0.54 94 125 0.24 14 09S -0.59 94 126 0.14 6 09S 0.64 95 107 0.17 10 08S 0.54 95 108 0.14 7 08S 0.53 95 109 0.16 10 09S 0.52 95 109 0.13 8 08S 0.59 95 111 0.12 8 08S 0.61 95 112 0.16 7 09S 0.51 95 112 0.14 7 08S 0.58 95 113 0.18 11 09S 0.50 95 115 0.17 10 09S 0.52 95 116 0.16 7 09S 0.55 95 117 0.19 11 09S 0.54 95 118 0.17 8 09S 0.53 95 121 0.16 10 09S 0.54 95 126 0.20 12 12S 0.50 96 1 0.35 17 12S -0.74 96 109 0.16 10 08S 0.57 96 111 0.11 7 08S 0.57 96 114 0.17 8 09S 0.53 96 116 0.20 9 09S 0.53 96 118 0.32 13 09S 0.53 96 119 0.18 11 11S -0.63 96 120 0.12 6 09S 0.58 96 124 0.16 7 14S 0.56 96 126 0.19 10 12S 0.51 97 9 0.23 11 14S -0.81 to 1CAN031703 Page 36 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 97 22 0.08 5 08S 0.47 97 23 0.28 13 08S 0.43 97 26 0.14 8 08S 0.42 97 96 0.13 8 08S 0.59 97 109 0.15 7 08S 0.60 97 114 0.16 10 09S 0.52 97 116 0.13 8 09S -0.54 97 116 0.34 18 09S 0.54 97 117 0.26 11 09S 0.56 97 119 0.21 9 09S 0.65 97 124 0.16 10 14S 0.64 98 6 0.10 5 10S 0.25 98 107 0.20 9 08S 0.60 98 108 0.18 11 08S -0.54 98 108 0.17 10 08S 0.57 98 109 0.21 9 08S -0.56 98 109 0.17 8 08S 0.58 98 110 0.16 10 08S 0.54 98 115 0.33 14 09S -0.58 98 116 0.19 11 09S 0.55 98 117 0.21 9 11S -0.62 98 117 0.16 7 09S 0.62 98 118 0.15 9 11S -0.64 98 120 0.13 8 11S -0.64 98 122 0.18 10 11S -0.62 98 122 0.19 11 14S 0.62 98 124 0.12 6 10S 0.33 98 125 0.20 10 12S -0.60 99 1 0.19 10 12S 0.35 99 4 0.09 5 10S 0.11 99 6 0.19 10 10S 0.02 99 7 0.21 11 10S 0.02 to 1CAN031703 Page 37 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 99 105 0.16 10 08S 0.57 99 107 0.19 11 08S -0.52 99 107 0.15 9 08S 0.59 99 113 0.16 10 09S 0.52 99 115 0.26 15 11S -0.64 99 115 0.26 14 09S -0.59 99 115 0.19 11 09S 0.55 99 116 0.20 9 13S -0.65 99 116 0.24 10 11S -0.65 99 119 0.27 15 14S 0.48 99 124 0.12 7 12S 0.56 99 124 0.19 10 13S 0.67 100 3 0.21 11 10S 0.27 100 4 0.21 10 14S -0.83 100 5 0.17 10 10S 0.11 100 7 0.29 15 10S 0.07 100 8 0.31 14 14S 0.23 100 21 0.20 11 08S 0.47 100 99 0.22 12 08S 0.61 100 108 0.12 6 08S 0.58 100 114 0.22 12 11S -0.64 100 114 0.17 10 09S -0.55 100 114 0.28 15 09S 0.57 100 115 0.26 11 11S -0.62 100 115 0.21 9 09S 0.60 100 118 0.12 7 14S 0.57 100 123 0.12 7 12S 0.63 101 7 0.20 11 10S 0.05 101 20 0.15 8 08S 0.43 101 22 0.12 6 08S 0.42 101 23 0.21 11 08S 0.43 101 104 0.11 7 08S 0.57 to 1CAN031703 Page 38 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 101 106 0.12 7 08S 0.61 101 108 0.19 11 09S 0.50 101 111 0.24 10 09S -0.56 101 112 0.37 19 11S -0.57 101 117 0.12 6 14S 0.56 101 120 0.26 13 12S 0.53 101 120 0.14 8 13S 0.63 102 7 0.28 15 10S 0.02 102 104 0.20 11 09S 0.48 102 108 0.17 10 09S 0.50 102 113 0.53 21 11S -0.65 102 114 0.21 12 11S -0.62 103 7 0.16 8 10S 0.13 103 110 0.16 8 08S 0.60 103 113 0.16 9 09S -0.55 104 6 0.27 14 04S -0.67 104 6 0.28 15 10S 0.07 104 7 0.22 10 10S 0.00 104 99 0.13 7 10S 0.52 104 99 0.19 10 09S 0.52 104 104 0.26 12 08S 0.58 104 105 0.17 10 09S 0.50 104 105 0.18 10 08S 0.57 104 106 0.13 7 08S 0.62 104 107 0.22 12 09S 0.55 104 108 0.22 10 08S 0.58 104 112 0.13 7 09S 0.56 104 113 0.31 16 11S -0.64 104 114 0.29 12 11S -0.61 104 118 0.24 11 14S 0.61 104 119 0.22 12 11S 0.55 104 121 0.18 10 12S 0.49 to 1CAN031703 Page 39 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 105 5 0.19 9 10S 0.13 105 29 0.16 8 08S 0.45 105 104 0.17 10 09S 0.53 105 104 0.13 8 08S 0.55 105 106 0.13 8 08S 0.55 105 110 0.21 12 09S 0.55 105 114 0.12 7 12S 0.60 105 115 0.15 7 10S 0.56 105 116 0.18 10 11S 0.59 105 117 0.26 13 12S -0.53 106 2 0.45 19 12S -0.74 106 2 0.38 17 12S 0.37 106 2 0.26 12 13S 0.42 106 102 0.17 8 08S 0.62 106 106 0.24 13 08S 0.57 106 112 0.18 10 09S 0.52 106 114 0.11 7 14S 0.64 107 3 0.20 10 10S 0.09 107 4 0.25 13 14S -0.79 107 100 0.11 5 08S 0.62 107 101 0.16 9 08S 0.57 107 102 0.14 7 08S 0.57 107 104 0.16 8 08S 0.57 107 113 0.32 17 11S 0.5 107 114 0.22 10 14S 0.52 107 117 0.15 8 11S -0.63 107 117 0.23 12 12S -0.58 107 117 0.20 10 12S 0.51 107 117 0.33 15 11S 0.53 108 2 0.12 6 10S 0.12 109 23 0.18 10 08S 0.45 109 26 0.14 7 08S 0.45 to 1CAN031703 Page 40 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 109 98 0.12 7 08S 0.57 109 99 0.15 7 08S 0.57 109 115 0.19 10 12S 0.51 110 1 0.26 13 12S -0.71 110 22 0.14 8 08S -0.74 110 22 0.22 12 08S 0.43 110 24 0.18 10 08S 0.42 110 25 0.15 7 08S 0.42 110 100 0.20 11 09S 0.53 110 109 0.15 8 14S 0.59 111 19 0.08 5 08S 0.42 111 98 0.18 10 08S 0.57 111 111 0.21 11 11S -0.61 112 28 0.15 7 08S 0.42 112 98 0.17 10 08S 0.57 112 113 0.27 15 11S 0.55 113 1 0.39 18 12S -0.71 113 24 0.17 8 08S 0.42 113 95 0.17 8 08S 0.60 113 96 0.14 9 08S 0.57 114 1 0.24 12 12S -0.74 114 22 0.12 6 08S 0.45 114 99 0.18 10 09S 0.50 114 110 0.25 11 11S -0.62 114 115 0.08 5 13S 0.58 115 1 0.43 20 12S -0.71 115 23 0.25 11 08S -0.74 115 88 0.29 13 06S -0.62 115 93 0.13 8 08S 0.61 115 95 0.15 9 08S 0.59 115 97 0.14 8 08S 0.52 116 1 0.66 27 12S -0.71 to 1CAN031703 Page 41 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 116 27 0.15 8 08S 0.45 116 86 0.18 10 08S 0.48 116 87 0.19 9 08S 0.54 116 113 0.51 22 10S 0.53 116 113 0.30 14 11S 0.58 117 1 1.67 44 12S -0.71 117 2 0.39 17 12S -0.72 117 91 0.14 8 08S 0.59 117 112 0.07 4 11S -0.55 117 112 0.28 14 10S -0.55 117 112 0.29 14 11S 0.58 118 3 0.39 17 12S -0.70 118 28 0.10 6 08S 0.45 118 31 0.19 10 08S 0.45 118 86 0.17 10 08S 0.57 118 87 0.26 12 08S -0.54 118 93 0.11 6 08S 0.56 118 106 0.23 13 11S -0.64 118 106 0.20 10 09S 0.55 118 111 0.15 8 10S -0.62 118 111 0.07 4 13S -0.49 118 111 0.22 11 11S 0.55 118 111 0.28 14 13S 0.63 119 6 0.21 10 14S -0.86 119 26 0.16 8 08S -0.65 119 26 0.17 8 08S 0.42 119 79 0.23 11 09S -0.62 119 79 0.19 10 08S 0.51 119 86 0.42 19 08S -0.52 119 86 0.33 16 08S 0.57 119 87 0.26 12 08S -0.62 119 87 0.19 9 08S 0.54 to 1CAN031703 Page 42 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 119 88 0.12 6 08S 0.57 119 107 0.21 11 11S 0.55 120 1 0.39 18 12S -0.76 120 22 0.16 8 08S 0.42 120 30 0.17 9 08S 0.46 120 32 0.22 11 08S 0.43 120 50 0.16 9 08S 0.49 120 80 0.17 10 08S 0.57 120 89 0.17 8 08S 0.54 120 100 0.29 13 11S -0.63 120 104 0.18 9 11S 0.58 121 1 0.32 16 12S -0.71 121 2 0.25 12 12S -0.74 121 9 0.21 11 14S 0.27 121 83 0.14 8 08S 0.57 121 101 0.17 10 10S 0.30 121 105 0.20 10 12S -0.60 121 105 0.21 11 11S 0.55 121 106 0.22 11 11S 0.58 122 1 0.59 25 12S -0.71 122 79 0.16 8 08S 0.56 122 89 0.15 8 08S 0.56 122 99 0.37 19 11S -0.62 122 99 0.12 7 09S -0.50 122 104 0.25 12 12S -0.53 122 104 0.20 10 12S 0.56 122 104 0.71 27 11S 0.58 122 105 0.23 12 10S -0.63 122 105 0.65 26 12S -0.62 122 105 0.65 26 11S 0.53 123 1 0.89 32 12S -0.76 123 10 0.31 14 14S -0.82 to 1CAN031703 Page 43 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 123 21 0.11 6 08S 0.43 123 31 0.17 9 08S -0.74 123 31 0.21 11 08S 0.47 123 78 0.11 6 08S 0.57 123 88 0.18 9 09S 0.52 123 98 0.14 7 09S -0.46 123 103 0.20 10 12S -0.65 123 103 0.36 17 11S 0.53 124 1 0.92 33 12S -0.69 124 2 0.25 13 12S -0.76 124 30 0.18 10 08S 0.45 124 32 0.14 8 08S 0.45 124 40 0.20 10 08S 0.45 124 77 0.14 7 08S 0.57 124 98 0.19 11 11S -0.57 124 101 0.19 10 11S -0.63 124 101 0.22 11 12S -0.60 124 101 0.22 11 11S 0.58 124 102 0.22 11 12S -0.60 124 102 0.15 8 12S 0.56 124 102 0.40 18 11S 0.60 124 103 0.42 19 10S -0.63 124 103 0.26 13 09S -0.62 125 1 0.22 12 11S -0.76 125 1 0.59 24 12S -0.71 125 1 0.21 11 12S 0.32 125 31 0.19 9 08S 0.43 125 39 0.24 11 08S 0.38 125 68 0.22 11 08S 0.54 125 70 0.37 17 08S -0.61 125 70 0.39 17 08S 0.52 125 71 0.24 14 08S 0.52 to 1CAN031703 Page 44 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 125 73 0.14 7 08S 0.55 125 86 0.22 11 09S -0.61 125 86 0.18 9 08S -0.56 125 86 0.22 10 08S 0.54 125 96 0.13 7 09S -0.54 125 97 0.16 8 11S -0.59 125 98 0.18 9 10S 0.36 125 100 0.18 9 12S -0.65 125 100 0.25 12 11S -0.63 125 101 0.22 11 12S -0.60 125 101 0.31 15 12S 0.56 126 1 0.95 33 12S -0.78 126 1 0.31 15 12S 0.32 126 7 0.27 13 12S 0.32 126 11 0.22 11 14S -0.88 126 40 0.09 5 08S 0.45 126 62 0.19 10 08S 0.48 126 73 0.11 6 08S 0.56 126 76 0.18 9 08S -0.55 126 76 0.20 12 08S 0.57 126 95 0.21 11 11S -0.63 126 96 0.20 11 10S 0.41 126 98 0.25 12 12S -0.62 126 99 0.16 9 12S 0.56 126 99 0.21 11 11S 0.60 127 1 0.86 31 12S -0.76 127 2 0.27 13 11S -0.83 127 7 0.36 16 12S 0.29 127 63 0.17 10 08S 0.50 127 65 0.21 12 08S 0.48 127 69 0.19 11 08S 0.43 127 74 0.13 7 08S 0.56 to 1CAN031703 Page 45 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 127 75 0.14 8 08S 0.55 127 80 0.21 11 08S -0.58 127 93 0.30 15 11S -0.61 127 96 0.42 19 12S -0.62 127 96 0.27 13 11S -0.53 127 96 0.22 11 11S 0.53 127 97 0.42 19 12S -0.58 127 97 0.32 15 11S -0.55 127 98 0.22 11 12S -0.60 127 98 0.45 20 11S 0.51 127 98 0.16 8 07S 0.53 127 98 0.27 13 12S 0.56 128 1 0.53 23 12S -0.74 128 6 0.28 13 10S -0.70 128 28 0.13 7 08S 0.45 128 28 0.07 4 07S 0.47 128 53 0.11 6 08S 0.43 128 58 0.18 10 08S 0.48 128 60 0.21 12 08S 0.62 128 64 0.18 10 08S 0.46 128 66 0.12 7 08S 0.55 128 68 0.15 9 08S 0.55 128 70 0.18 10 08S 0.52 128 81 0.19 10 11S -0.65 128 86 0.22 11 11S -0.63 128 87 0.18 10 11S -0.62 128 88 0.16 8 10S 0.34 128 91 0.32 15 12S -0.60 128 91 0.18 9 12S 0.58 129 1 0.95 33 12S -0.74 129 28 0.16 9 08S 0.42 129 29 0.15 8 08S 0.43 to 1CAN031703 Page 46 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 129 38 0.13 7 08S 0.45 129 83 0.15 8 09S 0.56 129 84 0.19 10 09S 0.54 129 87 0.19 10 11S -0.63 129 90 0.10 6 14S 0.55 129 93 0.15 8 12S 0.60 129 94 0.36 17 12S 0.56 130 1 0.31 15 12S -0.78 130 2 0.30 15 14S -0.86 130 2 0.31 15 12S -0.78 130 2 0.43 20 11S -0.74 130 32 0.10 6 08S 0.47 130 34 0.07 4 10S -0.78 130 38 0.14 8 06S 0.47 130 38 0.22 12 08S 0.49 130 41 0.18 9 08S 0.47 130 48 0.14 8 08S 0.49 130 49 0.26 14 08S 0.43 130 63 0.18 10 08S 0.50 130 69 0.13 8 08S -0.55 130 69 0.12 7 08S 0.52 130 85 0.19 10 12S -0.62 130 86 0.19 10 12S -0.62 130 86 0.23 12 12S 0.52 130 86 0.09 5 11S 0.56 130 88 0.16 9 10S 0.27 130 92 0.19 10 10S -0.63 130 92 0.71 27 12S -0.62 130 93 0.29 14 11S 0.53 131 1 0.34 16 12S -0.78 131 8 0.20 11 10S -0.76 131 13 0.22 11 14S 0.23 to 1CAN031703 Page 47 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 131 59 0.18 10 08S 0.43 131 82 0.14 7 09S -0.55 131 83 0.18 10 11S -0.57 131 83 0.15 9 09S 0.55 131 84 0.18 10 11S -0.62 131 86 0.25 13 12S 0.56 131 87 0.18 10 12S 0.59 131 89 0.21 11 12S -0.60 131 90 0.31 15 12S -0.65 132 1 0.60 25 12S -0.76 132 3 0.22 11 12S -0.79 132 7 0.31 14 14S -0.86 132 7 0.25 12 06S -0.63 132 38 0.18 10 08S 0.36 132 82 0.35 17 11S -0.62 132 82 0.21 11 09S 0.54 132 86 0.14 8 13S 0.57 132 87 0.19 10 12S -0.63 132 87 0.21 11 11S -0.56 132 88 0.57 23 12S -0.58 132 88 0.40 18 11S -0.53 132 88 0.23 11 13S -0.51 132 88 0.14 7 09S 0.56 132 88 0.19 10 12S 0.56 132 88 0.24 12 13S 0.60 132 89 0.18 9 12S -0.60 132 89 0.49 21 10S -0.53 132 89 0.38 17 11S 0.58 133 8 0.27 13 13S 0.20 133 9 0.16 9 07S -0.71 133 9 0.21 11 13S 0.27 133 14 0.20 10 14S -0.88 to 1CAN031703 Page 48 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 133 80 0.16 9 14S 0.48 133 81 0.23 12 12S -0.60 133 82 0.26 14 12S -0.59 133 84 0.14 8 12S -0.57 133 84 0.17 10 10S -0.57 133 86 0.44 19 12S -0.60 133 86 0.24 12 11S 0.58 133 87 0.43 19 12S -0.67 133 87 0.22 11 11S 0.55 133 87 0.23 12 13S 0.65 133 88 0.41 19 12S -0.62 133 88 0.19 10 11S 0.58 134 1 0.38 18 12S -0.76 134 1 0.13 7 12S 0.37 134 4 0.21 10 12S -0.78 134 4 0.20 10 12S 0.38 134 78 0.11 6 09S 0.52 134 79 0.25 13 11S -0.65 134 79 0.28 14 13S 0.54 134 84 0.70 27 12S -0.64 134 84 0.18 9 10S -0.60 134 84 0.40 18 11S -0.60 134 84 0.14 7 09S 0.55 134 84 0.19 10 08S 0.55 134 84 0.22 11 11S 0.55 134 85 0.22 11 10S -0.62 134 85 0.42 19 12S -0.62 134 85 0.14 7 13S 0.65 135 15 0.24 12 14S -0.85 135 32 0.28 13 14S 0.25 135 77 0.14 8 09S 0.54 135 78 0.19 11 11S -0.62 to 1CAN031703 Page 49 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 135 78 0.20 11 14S 0.53 135 82 0.37 17 12S -0.60 135 82 0.28 14 11S -0.53 135 82 0.46 20 12S 0.58 135 83 0.19 10 11S -0.60 135 83 0.38 17 12S -0.58 135 83 0.27 13 13S -0.51 135 83 0.23 11 11S 0.58 135 83 0.37 17 13S 0.62 135 84 0.28 14 12S -0.62 135 84 0.21 11 13S -0.46 136 7 0.21 10 13S 0.32 136 8 0.31 14 12S -0.73 136 8 0.34 15 12S 0.36 136 67 0.19 10 11S -0.65 136 71 0.38 18 14S -0.65 136 73 0.20 10 14S 0.50 136 76 0.12 7 14S 0.55 136 77 0.33 16 12S 0.61 136 77 0.15 8 13S 0.63 136 79 0.31 15 12S -0.62 136 79 0.17 9 13S -0.51 136 80 0.48 21 12S -0.60 136 80 0.22 11 13S -0.44 136 80 0.15 8 07S 0.55 136 80 0.24 12 11S 0.55 136 80 0.24 12 13S 0.63 136 81 0.23 12 10S -0.64 136 81 0.15 8 11S -0.62 136 81 0.35 17 12S -0.53 136 81 0.21 11 13S -0.39 136 81 0.42 19 11S 0.53 to 1CAN031703 Page 50 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 136 81 0.36 17 13S 0.65 137 1 0.11 6 12S 0.32 137 3 0.21 11 12S -0.76 137 8 0.07 4 11S -0.77 137 8 0.20 10 12S 0.38 137 9 0.24 12 13S 0.31 137 10 0.44 19 14S 0.23 137 65 0.22 11 09S -0.67 137 65 0.23 11 11S -0.65 137 66 0.24 12 11S -0.64 137 67 0.20 10 11S -0.65 137 69 0.34 16 11S -0.62 137 70 0.52 23 11S 0.00 137 77 0.25 12 10S -0.67 137 77 0.14 7 13S -0.51 137 77 0.17 9 13S 0.60 137 78 0.43 19 12S -0.60 137 79 0.26 13 11S -0.58 137 79 0.42 19 12S -0.53 137 79 0.57 23 13S -0.49 137 80 0.16 8 11S 0.58 138 7 0.26 12 14S 0.25 138 7 0.25 12 13S 0.31 138 9 0.23 11 14S -0.85 138 9 0.24 12 14S 0.25 138 9 0.25 12 13S 0.36 138 62 0.42 19 11S -0.65 138 63 0.22 11 11S -0.66 138 64 0.25 12 11S -0.67 138 67 0.10 5 13S 0.48 138 68 0.22 11 10S 0.16 138 69 0.31 15 11S -0.55 to 1CAN031703 Page 51 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 138 74 0.25 12 11S -0.65 138 75 0.21 11 11S -0.65 138 75 0.36 17 12S -0.62 138 76 0.24 12 12S -0.58 138 76 0.37 17 13S -0.53 138 77 0.15 8 11S 0.57 139 7 0.08 4 10S -0.74 139 57 0.11 6 09S -0.56 139 58 0.22 11 11S -0.70 139 59 0.33 15 11S -0.67 139 60 0.27 14 11S -0.64 139 64 0.16 9 12S -0.62 139 64 0.12 7 12S 0.55 139 67 0.24 12 10S 0.27 139 68 0.22 12 11S -0.64 139 71 0.19 10 12S -0.65 139 72 0.20 10 12S -0.62 139 72 0.28 13 12S -0.62 139 72 0.29 14 12S 0.58 139 72 0.34 15 12S 0.60 139 73 0.19 10 11S -0.67 139 73 0.25 12 12S -0.62 139 74 0.52 23 12S -0.55 139 74 0.23 12 12S 0.64 140 3 0.23 12 13S -0.69 140 7 0.32 15 13S -0.76 140 10 0.34 15 15S 0.25 140 10 0.23 11 14S 0.27 140 11 0.20 10 13S 0.34 140 12 0.15 8 15S 0.22 140 12 0.20 10 14S 0.27 140 15 0.25 12 13S 0.27 to 1CAN031703 Page 52 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 140 55 0.24 12 11S -0.70 140 55 0.27 13 13S 0.45 140 56 0.59 24 11S 0.00 140 56 0.25 12 10S 0.16 140 56 0.23 11 12S 0.45 140 59 0.18 10 13S -0.55 140 59 0.32 16 14S 0.44 140 62 0.29 14 14S 0.45 140 65 0.11 6 11S -0.62 140 65 0.15 8 14S 0.46 140 67 0.36 17 12S -0.64 140 69 0.19 10 11S -0.65 140 69 0.45 20 12S -0.53 141 6 0.16 8 13S -0.75 141 9 0.38 17 15S 0.24 141 10 0.24 11 15S 0.27 141 10 0.23 11 13S 0.34 141 12 0.15 8 15S -0.79 141 14 0.17 9 12S 0.36 141 16 0.11 6 14S -0.77 141 16 0.27 13 10S -0.72 141 17 0.29 14 14S -0.79 141 27 0.27 13 14S 0.31 141 54 0.13 7 11S -0.54 141 55 0.30 14 11S -0.65 141 56 0.23 12 14S -0.65 141 56 0.30 14 10S 0.31 141 58 0.18 10 13S -0.57 141 59 0.24 12 13S -0.56 141 60 0.19 10 14S 0.48 141 61 0.13 7 13S -0.50 141 61 0.20 10 14S 0.52 to 1CAN031703 Page 53 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 141 62 0.13 7 13S -0.60 141 62 0.11 6 14S 0.44 141 63 0.24 12 13S -0.50 141 63 0.14 7 14S 0.50 141 63 0.14 7 12S 0.63 141 64 0.13 7 12S 0.62 141 67 0.25 12 11S -0.67 141 68 0.27 13 13S -0.56 141 68 0.18 10 12S -0.55 142 4 0.28 13 11S -0.72 142 23 0.25 12 14S -0.74 142 52 0.20 10 11S -0.65 142 53 0.27 13 11S -0.65 142 54 0.14 7 10S 0.38 142 54 0.33 15 14S 0.41 142 56 0.22 11 14S 0.43 142 64 0.28 13 12S -0.60 142 64 0.16 8 11S 0.53 142 64 0.50 21 12S 0.62 142 65 0.11 6 11S -0.68 142 65 0.16 9 10S -0.59 142 65 0.12 7 13S -0.48 143 3 0.20 11 14S 0.18 143 7 0.12 6 13S -0.72 143 12 0.27 13 14S -0.76 143 12 0.20 10 13S 0.34 143 13 0.28 13 14S 0.27 143 13 0.33 15 13S 0.32 143 21 0.23 11 14S -0.72 143 50 0.23 12 11S 0.46 143 51 0.23 11 14S 0.38 143 56 0.08 5 13S -0.50 to 1CAN031703 Page 54 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 143 56 0.14 8 13S 0.50 143 60 0.18 10 12S -0.62 143 60 0.22 12 13S -0.55 144 9 0.22 11 15S -0.75 144 11 0.25 12 13S -0.68 144 11 0.29 14 14S 0.20 144 11 0.20 10 12S 0.41 144 13 0.30 14 10S -0.72 144 38 0.15 8 09S -0.65 144 40 0.37 17 09S -0.65 144 48 0.24 12 13S -0.52 144 48 0.22 11 13S 0.43 144 51 0.36 17 13S -0.60 144 51 0.40 19 14S 0.49 144 52 0.21 10 13S -0.46 144 52 0.14 7 13S 0.53 144 53 0.18 10 13S 0.53 145 2 0.29 13 08S -0.66 145 10 0.25 12 10S -0.74 145 11 0.30 14 11S -0.75 145 13 0.20 10 14S -0.78 145 13 0.31 14 12S -0.73 145 13 0.24 12 12S 0.38 145 15 0.60 23 10S -0.70 145 16 0.25 12 11S -0.72 145 28 0.20 10 12S 0.38 145 33 0.18 10 13S 0.37 145 35 0.09 5 10S 0.32 145 36 0.25 12 11S -0.67 145 47 0.21 10 14S -0.63 145 47 0.20 10 13S -0.51 145 47 0.49 20 14S 0.35 to 1CAN031703 Page 55 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 145 48 0.27 14 12S 0.48 145 48 0.47 21 13S 0.48 145 48 0.23 12 14S 0.51 145 49 0.32 15 14S 0.37 145 50 0.26 13 12S -0.62 145 50 0.21 11 13S 0.55 146 1 0.25 13 11S -0.73 146 7 0.29 14 12S -0.70 146 9 0.28 13 14S -0.75 146 10 0.16 8 10S -0.68 146 12 0.29 13 10S -0.67 146 12 0.18 9 12S 0.39 146 13 0.20 10 12S -0.71 146 13 0.24 12 12S 0.38 146 14 0.26 12 10S -0.70 146 20 0.28 13 14S -0.77 146 20 0.12 6 10S -0.02 146 22 0.28 13 11S -0.70 146 24 0.29 14 11S -0.70 146 25 0.28 13 11S -0.68 146 30 0.21 10 13S -0.65 146 32 0.21 10 10S 0.13 146 33 0.19 10 10S 0.23 146 36 0.24 12 10S 0.18 146 37 0.21 11 10S 0.23 146 40 0.14 8 11S -0.64 146 44 0.18 10 10S 0.14 146 47 0.33 16 13S 0.51 147 8 0.24 11 10S -0.68 147 9 0.25 12 10S -0.67 147 13 0.21 10 14S -0.77 147 15 0.20 10 14S 0.36 to 1CAN031703 Page 56 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 147 21 0.34 15 14S -0.75 147 26 0.17 9 11S -0.70 147 26 0.26 13 13S -0.65 147 27 0.08 5 10S 0.16 147 28 0.14 7 10S 0.13 147 29 0.25 13 10S 0.21 147 40 0.21 11 14S 0.46 147 41 0.23 11 14S 0.35 147 41 0.15 8 13S 0.53 147 42 0.21 11 11S -0.66 147 42 0.32 16 14S 0.35 147 42 0.20 11 13S 0.53 148 1 0.19 10 13S -0.74 148 3 0.21 10 11S -0.69 148 3 0.22 11 13S -0.69 148 4 0.21 11 11S -0.76 148 4 0.43 19 12S -0.71 148 4 0.27 14 13S -0.69 148 4 0.39 18 10S -0.69 148 23 0.23 11 12S 0.43 148 25 0.17 9 10S 0.13 148 26 0.12 7 10S 0.16 148 26 0.21 11 12S 0.44 148 32 0.11 6 13S 0.53 148 38 0.21 11 14S 0.42 148 39 0.45 21 14S 0.46 149 1 0.18 10 11S -0.73 149 1 1.65 44 12S -0.67 149 1 0.33 16 14S 0.00 149 2 0.27 13 13S -0.67 149 4 0.21 10 11S -0.71 149 4 0.71 26 12S -0.71 to 1CAN031703 Page 57 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 149 5 0.28 14 11S -0.71 149 5 0.21 11 13S -0.69 149 5 0.52 22 12S -0.66 149 6 0.61 23 11S -0.76 149 6 1.30 38 12S -0.69 149 6 0.23 11 13S -0.64 149 7 0.50 22 12S -0.69 149 8 0.51 21 12S -0.65 149 9 0.31 14 12S -0.69 149 14 0.11 6 10S 0.45 149 17 0.18 9 13S 0.38 149 31 0.30 14 11S -0.69 150 1 0.31 15 12S -0.71 150 2 0.21 11 12S -0.69 150 3 0.50 20 12S -0.69 150 5 0.25 13 13S -0.72 150 5 1.52 42 12S -0.69 150 6 0.22 11 13S -0.69 150 6 0.64 24 12S -0.66 150 7 0.42 19 12S -0.71 150 7 0.27 14 13S -0.69 150 7 0.31 15 10S 0.41 150 8 0.29 13 12S -0.69 150 9 0.19 10 11S -0.71 150 9 0.55 23 12S -0.67 150 9 0.21 11 12S 0.37 150 10 0.24 11 13S -0.67 150 12 0.26 13 10S -0.66 150 16 0.23 12 12S -0.68 150 16 0.43 20 10S -0.68 150 16 0.14 8 12S 0.44 150 17 0.27 14 11S -0.73 to 1CAN031703 Page 58 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 150 17 0.29 15 12S -0.64 150 18 0.31 16 11S -0.70 150 18 0.25 13 12S -0.68 150 19 0.20 11 13S -0.69 150 19 0.35 17 11S -0.68 150 19 0.23 12 12S -0.66 150 20 0.27 14 11S -0.73 150 20 0.39 19 12S -0.63 150 20 0.20 11 12S 0.43 150 21 0.23 12 11S -0.70 150 21 0.25 13 12S 0.41 150 22 0.29 15 11S -0.70 150 22 0.36 17 12S -0.66 150 23 0.33 16 11S -0.70 150 23 0.23 12 12S -0.66 150 23 0.18 10 12S 0.48 150 24 0.49 22 11S -0.71 150 24 0.19 10 12S -0.66 150 25 0.56 24 11S -0.71 150 25 0.22 12 13S -0.69 150 25 0.31 15 13S 0.41 150 25 0.37 18 12S 0.50 150 26 0.48 22 11S -0.73 150 26 0.14 8 13S -0.66 150 26 0.32 16 13S 0.44 150 26 0.48 22 12S 0.46 150 27 0.45 21 11S -0.71 150 27 0.26 13 13S -0.69 150 27 0.40 19 12S -0.68 150 27 0.65 27 12S 0.39 150 28 0.28 13 11S -0.67 150 29 0.37 18 11S -0.69 to 1CAN031703 Page 59 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 150 29 0.21 11 13S -0.57 150 30 0.37 17 12S -0.62 150 30 0.25 12 12S 0.51 150 31 0.25 13 12S -0.62 151 1 0.43 19 12S -0.69 151 1 0.20 10 10S 0.46 151 2 0.27 12 11S -0.73 151 2 0.79 28 12S -0.69 151 2 0.21 10 12S 0.37 151 3 0.60 25 12S -0.71 151 3 0.31 15 13S -0.67 151 3 0.21 11 10S 0.44 151 4 0.33 15 12S -0.69 151 4 0.56 22 11S 0.41 151 4 0.86 30 10S 0.44 151 5 0.57 24 12S -0.68 151 5 0.41 19 10S 0.46 151 6 0.57 22 12S -0.69 151 6 0.22 11 10S 0.44 151 7 0.27 14 12S -0.71 151 7 0.17 9 13S 0.39 151 8 0.21 11 11S -0.69 151 8 0.49 22 12S -0.66 151 8 0.17 9 10S 0.48 151 9 0.24 13 12S -0.68 151 9 0.42 19 10S -0.68 151 9 0.29 15 13S 0.41 151 10 0.17 10 08S -0.70 151 10 0.37 18 13S -0.69 151 10 0.27 14 12S -0.68 151 11 0.44 20 12S -0.66 151 12 0.19 10 13S -0.69 to 1CAN031703 Page 60 of 60 ROW COL VOLTS %TW TSP Elevation (Inches) 151 12 0.34 17 12S -0.66 151 12 0.20 11 12S 0.37 151 13 0.19 10 12S -0.66 151 14 0.18 10 13S -0.69 151 14 0.20 11 12S -0.68 151 15 0.27 14 11S -0.73 151 15 0.43 20 13S -0.69 151 15 0.92 33 12S -0.68 151 15 0.65 27 12S 0.39 151 15 0.40 19 13S 0.41 151 15 0.19 10 11S 0.48 151 16 0.40 19 11S -0.70 151 16 0.36 17 13S -0.68 151 16 0.54 23 12S -0.68 151 16 0.33 16 13S 0.41 151 16 0.21 11 12S 0.46 151 17 0.22 12 11S -0.73 151 17 0.34 17 13S -0.71 151 17 0.61 26 12S -0.68 151 17 0.28 14 13S 0.41 151 18 0.19 10 11S -0.70 151 18 0.41 19 13S -0.69 151 18 0.25 13 12S -0.66 151 19 0.41 19 11S -0.73 151 19 0.29 15 13S -0.69 151 19 0.53 23 12S -0.68 151 19 0.34 17 12S 0.44 151 20 0.24 13 13S -0.69 151 20 0.27 14 12S -0.64 151 21 0.48 22 12S -0.66 151 24 0.18 10 12S 0.55