ML100321371: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
 
Line 17: Line 17:


=Text=
=Text=
{{#Wiki_filter:ATTACHMENT 14 Mechanical Drawings for Leading Edge Flowmeter Installation  
{{#Wiki_filter:ATTACHMENT 14 Mechanical Drawings for Leading Edge Flowmeter Installation LIST OF DRAWINGS INCLUDED M-802, Sheet 2, Rev. V, Feedwater Piping System (LSCS, Unit 1)


LIST OF DRAWINGS INCLUDED M-802, Sheet 2, Rev. V, Feedwater Piping System (LSCS, Unit 1)
8                    7                                    6                    5            4                            3                              2 Z 'lHS Z08-V'l
 
                                                                                                                                      --------+--rl~
F c B 1" PLUG CONN.lYP, (2)CHORDAL SPOOL PIECE (CALDON)FEEDWATER PIPING SYSTEM (FOR FLUSHING PURPOSES)DETAIL B (lYPICAL 2 PLACES)SCALE: lit'=1'-0 24"-1500#W.N.FLANGE TYP.24" SCH 160 PIPE (APPROX.19'-2¥" LG)2 v FLOW STRAIGHTENER (INSIDE 24" NPS PIPE)24" SCH 160 PIPE (APPROX.5'-8¥" LG)(EXISTING)
F F
¥.'-6000 LB 2 PLS (PRESSURE CONN.)(EXISTING)
v (FOR FLUSHING PURPOSES) 24" -1500# W.N.
....
FLANGE   TYP.
A 3 3 4 4"---4---FOR CONT.SEE DWe M-S66 SHT.71:>5 5 1.SEE CAMERON OWG'S 300C096 SHEETS 1 THRU 5 FOR LEFM CHORDAL SPOOL PIECE DETAILS 2.SEE DWG 131 C7599 SHEET 1 FOR REFERENCE DETAILS R 6 7 7 SECTION SEC.TION"21-2'-8 8 Z'lHS Z08-V'l F E o c B A}}
                                                                                                    " - - - - FOR CONT. SEE DWe E                                                                                                                    M-S66 SHT. 71:>
FLOW STRAIGHTENER (INSIDE 24" NPS PIPE) o                                                                                                                                                              24" SCH 160 PIPE (APPROX. 19'-2¥" LG)
                                          ---I-----I~              R c                                                                                                                                                                                                                              c 1" PLUG CONN.
lYP, (2)
CHORDAL SPOOL PIECE (CALDON)
SEC.T ION  "21-2'-
B B                                                                                                                                                                24" SCH 160 PIPE (APPROX. 5'-8¥" LG)
(EXISTING)
                                                                                                                                                                ¥.' -6000 LB   2 PLS (PRESSURE CONN.)
(EXISTING)       ~----~....
SECTION                                                                                                                                                              DETAIL B (lYPICAL 2 PLACES)
SCALE: lit' = 1'-0
:BCtFO;;;R:;R&#xa3;:COR1l:::PER~~~C3SJ<<8~RlPll~ON~.===4!!~~ngr----------------I A A
FEEDWATER PIPING SYSTEM LEFM
: 1. SEE CAMERON OWG'S 300C096 SHEETS 1 THRU 5 FOR CHORDAL SPOOL PIECE DETAILS
: 2. SEE DWG 131 C7599 SHEET 1 FOR REFERENCE DETAILS 8                    7                                                         5            4                            3}}

Latest revision as of 23:13, 13 November 2019

Attachment 14 - Mechanical Drawings for Leading Edge Flowmeter Installation
ML100321371
Person / Time
Site: LaSalle  Constellation icon.png
Issue date: 01/27/2010
From:
Exelon Generation Co, Exelon Nuclear
To:
Office of Nuclear Reactor Regulation
Shared Package
ML100321303 List:
References
RS-10-001
Download: ML100321371 (2)


Text

ATTACHMENT 14 Mechanical Drawings for Leading Edge Flowmeter Installation LIST OF DRAWINGS INCLUDED M-802, Sheet 2, Rev. V, Feedwater Piping System (LSCS, Unit 1)

8 7 6 5 4 3 2 Z 'lHS Z08-V'l


+--rl~

F F

v (FOR FLUSHING PURPOSES) 24" -1500# W.N.

FLANGE TYP.

" - - - - FOR CONT. SEE DWe E M-S66 SHT. 71:>

FLOW STRAIGHTENER (INSIDE 24" NPS PIPE) o 24" SCH 160 PIPE (APPROX. 19'-2¥" LG)

---I-----I~ R c c 1" PLUG CONN.

lYP, (2)

CHORDAL SPOOL PIECE (CALDON)

SEC.T ION "21-2'-

B B 24" SCH 160 PIPE (APPROX. 5'-8¥" LG)

(EXISTING)

¥.' -6000 LB 2 PLS (PRESSURE CONN.)

(EXISTING) ~----~....

SECTION DETAIL B (lYPICAL 2 PLACES)

SCALE: lit' = 1'-0

BCtFO;;;R:;R£:COR1l:::PER~~~C3SJ<<8~RlPll~ON~.===4!!~~ngr----------------I A A

FEEDWATER PIPING SYSTEM LEFM

1. SEE CAMERON OWG'S 300C096 SHEETS 1 THRU 5 FOR CHORDAL SPOOL PIECE DETAILS
2. SEE DWG 131 C7599 SHEET 1 FOR REFERENCE DETAILS 8 7 5 4 3