Line 3: |
Line 3: |
| | issue date = 05/31/2006 | | | issue date = 05/31/2006 |
| | title = Relief, Third 10-Year ISI Interval | | | title = Relief, Third 10-Year ISI Interval |
| | author name = Monarque S R | | | author name = Monarque S |
| | author affiliation = NRC/NRR/ADRO/DORL | | | author affiliation = NRC/NRR/ADRO/DORL |
| | addressee name = Christian D A | | | addressee name = Christian D |
| | addressee affiliation = Virginia Electric & Power Co (VEPCO) | | | addressee affiliation = Virginia Electric & Power Co (VEPCO) |
| | docket = 05000280 | | | docket = 05000280 |
Similar Documents at Surry |
---|
Category:Code Relief or Alternative
MONTHYEARML23244A2352023-09-18018 September 2023 Request to Use a Subsequent Edition of the ASME Code, Section XI ML23102A2832023-04-25025 April 2023 ASME OM Code Inservice Testing Program Request for Approval of Alternative Request V-01 Use of Mechanical Agitation Process for Pressure Isolation Valve 1-SI-241 Seat Leakage Testing ML23073A1912023-04-21021 April 2023 Alternative for Inservice Inspections of Pressurizer and Steam Generator Weld Examinations ML22342A1002022-12-0707 December 2022 Relief Request Acceptance Review Results; Surry ISI Alternative, Prz and SG Welds and Nozzles ML19043A8242019-03-15015 March 2019 Relief Requests Examination Coverage for Pressurizer Nozzle Inner Radius Sections and Certain Stainless Steel Piping Welds (S2-15-LMT-CO1 and S2-15-LMT-P01) ML18331A0602019-02-28028 February 2019 Relief Requests Regarding Examination Coverage for Pressurizer Nozzle Inner Radius Section and Certain Stainless Steel Piping Welds (S1-I5-LMT-C01 and S1-I5-LMT-P01) ML18236A2362018-09-26026 September 2018 Relief from the Requirements of the ASME Code - Proposed Alternatives S1-I5-ISI-04 and S2-I5-ISI-04 ML18068A0642018-03-26026 March 2018 Relief from the Requirements of the ASME Code Repair/Replacement of Buried Circulating and Service Water Class 3 Piping with Carbon Fiber Reinforced Polymer (CAC Nos. MF8987 and MF8988; EPID L-2016-LLR-0019) ML17303A0682017-12-20020 December 2017 Nonproprietary Relief from the Requirements of the ASME Code (CAC Nos. MF8987 and MF8988; EPID L-2016-LLR-0019) ML16365A1182017-02-17017 February 2017 Requests for Relief LMT-R01, LMT-SS01, LMT-CS01, LMT-P01, LMT-C01, LMT-C02, LMT-C03, and LMT-C04 - for Limited Coverage Examinations Performed in the Fourth 10-Year Inservice Inspection Interval ML16208A0092016-08-24024 August 2016 Requests for Relief LMT-R01, LMT-R02, LMT-R03, LMT-P01, and LMT-C01, Alternatives to ASME Code Requirements for Limited Coverage from the Requirements of the ASME Code ML15023A4412015-03-16016 March 2015 Alternatives to the Requirements of the ASME Code and Use of a Subsequent Edition and Addenda of the ASME B&PV Code, Section XI ML15029A4242015-02-10010 February 2015 Fifth 10-Year Inservice Inspection Interval Request for Subsequent Edition/Addenda ML14309A6662014-11-25025 November 2014 Relief from the Requirements of the ASME Code ML14125A4712014-05-0909 May 2014 Relief from the Requirements of the ASME Code ML14115A1992014-04-30030 April 2014 Relief from the Requirements of the ASME OM Code ML14113A3462014-04-25025 April 2014 Relief from the Requirements of the ASME Code ML13204A2972013-08-0101 August 2013 Relief from the Requirements of the ASME Code (Tacs. MF0329 and MF0330) ML13106A1402013-04-30030 April 2013 Relief from the Requirements of the ASME Code Section XI for the Fourth Ten-Year Inservice Inspection Program Interval ML12348A0082012-11-0909 November 2012 ASME Section XI Inservice Inspection (Isl) Program Request for Alternative - Reactor Vessel Nozzle to Safe End Butt Welds Examination Relief Requests CMP-008 and CMP-010 ML12130A2172012-04-25025 April 2012 ASME Section XI Inservice Inspection (ISI) Program Request for Alternative - Implementation of Extended Reactor Vessel Inservice Inspection Interval Relief Requests CMP-007 and CMP-009 ML0930003522009-10-27027 October 2009 Submittal of Relief Request SPT-004, Revision 2, SPT-003, Revision 2 and Elimination of NRC Bulletin 2003-02 Commitment ML0714403422007-08-0303 August 2007 Relief Request to Use Portion of 2001 Edition of American Society of Mechanical Engineers Code ML0712700162007-06-0505 June 2007 Relief, Forth 10-Year Inservice Inspection Interval Relief Request CMP-001, Revision 1 ML0633402942006-11-29029 November 2006 Surrry, Unit No. 2, Reply to Fourth 10-Year Inservice Inspection Interval Relief Request CMP-007, TAC MD2673 ML0615103652006-05-31031 May 2006 Relief, Third 10-Year ISI Interval ML0611706232006-04-27027 April 2006 Relief, Section XI Inservice Inspection Program Relief Requests PRT-07 and PRT-08 NRC Safety Evaluation Report Discrepancy ML0608701372006-04-14014 April 2006 Third 10-Year Inservice Inspection Interval Relief Requests PRT-01 and PRT-02 ML0607304682006-03-28028 March 2006 Relief, Third 10-Year Inservice Inspection Interval PRT-07 ML0605402842006-03-28028 March 2006 Third 10-Year Inservice Inspection Interval Relief Request PRT-08 ML0604405462006-02-0202 February 2006 Relief, Containment Relief Request IWL1 ML0530402032005-11-0101 November 2005 Relief Request, Fourth 10-Year Inservice Inspection SPT-008 ML0529300322005-11-0101 November 2005 Relief, Fourth 10-Year Inservice Inspection Program, MC5586, MC5587, MC5596, MC5597, MC5598, and MC5600 ML0526903172005-09-28028 September 2005 Relief Request, ASME Section XI ISI on Partial Examination (Tac No. MC4633, MC4634, MC4635, MC4636, MC4637) ML0520800062005-08-0808 August 2005 Relief, Safety Significant Socket Weld Examinations, TAC MC3134 ML0515302482005-05-20020 May 2005 ASME Section XI Inservice Inspection Relief Request Main Steam Line Branch Connection Weldolets ML0514604312005-05-20020 May 2005 RR, Correction Letter for SR-36 ML0510101962005-04-11011 April 2005 ASME Section XI Relief Request Alternative Acceptance Criteria for Surface Examinations ML0510204862005-04-0808 April 2005 RR-8, ASME IST Requirements on Spray Pumps for Revised Relief P-8 (Tac No. MC6258) ML0504806682005-02-17017 February 2005 SE, Correction for ASME ISI (Tac No. MC3142, MC3143) ML0503406172005-02-0101 February 2005 Ltr, Authorization of RR SR-036 & SR-037 ML0501804952005-01-10010 January 2005 ASME Section XI Inservice Inspection Program, End of Intervals System Pressure Testing ML0500400542005-01-0404 January 2005 Relief, Interval Request for Relief SR-004, Rev. 2, TAC MC3693 ML0429504442004-10-16016 October 2004 Relief Request, American Society of Mechanical Engineers Inservice Inspection Program Third 10-Year Interval ML0429402892004-10-11011 October 2004 ASME Section Xl Inservice Inspection Program Partial Examination Relief Request ML0427304532004-09-28028 September 2004 American Society of Mechanical Engineers Inservice Testing Program, Revised Relief Requests P-2 ML0425900412004-09-13013 September 2004 Relief, Risk-Informed Inservice Inspection Relief Request R-1 ML0424606322004-09-0101 September 2004 Fourth Interval Inservice Testing Program Revised Relief Requests P-2 ML0419101182004-07-0202 July 2004 7/2/04, Surry, Units 1 & 2, Relief, Certain American Society of Mechanical Engineers (ASME) Inservice Testing (IST) Requirements. Proposed Alternatives in Relief Requests P-1, P3, P-4, P-5, P-6, P-7, V-2, V-3, V-4, V-5 & V-6 Acceptable ML0412700022004-05-0404 May 2004 Request to Use Code Case N-663 as an Alternative for Surface Examination of ASME Code Class 2 Piping Welds(Tac MC2489, MC2490, MC2491, MC2523 & MC2524) 2023-09-18
[Table view] Category:Letter
MONTHYEARIR 05000280/20244012024-02-0606 February 2024 Security Baseline Inspection Report 05000280/2024401, 05000281/2024401 and 07200002/2024401 IR 05000280/20230102024-01-18018 January 2024 Age Related Degradation Inspection Report 05000280-2023010 and 05000281-2023010 ML23312A1922024-01-18018 January 2024 Issuance of Amendment Nos. 316 & 316 Regarding a Risk Informed Approach for Tornado Classification of the Fuel Handling Trolley Support Structure ML24003A9022024-01-0303 January 2024 Stations, Units 1 and 2, Emergency Plan Revision - Relocation of the Technical Support Center (TSC) - Editorial Correction IR 05000280/20233012023-12-28028 December 2023 NRC Operator License Examination Report 05000280/2023301 and 05000281/2023301 ML23283A3052023-12-20020 December 2023 Review of Appendix F to DOM-NAF2, Qualification of the Framatome ORFEO-GAIA and ORFEO-NMGRID CHF Correlations in the Dominion Energy VIPRE-D Computer Code (EPID L-2022-LLT-0003) (Nonproprietary) ML23352A3692023-12-18018 December 2023 Associated Independent Spent Fuel Storage Installation, Revision to Emergency Plan Report of Change ML23334A2342023-11-30030 November 2023 Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation ML23242A2292023-11-0707 November 2023 Issuance of Amendment Nos. 315 and 315, Regarding Emergency Procedure Relocation of the Technical Support Center ML23200A2622023-11-0202 November 2023 Issuance of Amendment Nos. 314 and 314, Regarding Technical Specification and Spent Fuel Pool Criticality Change IR 05000280/20230032023-10-25025 October 2023 Integrated Inspection Report 05000280/2023003 and 05000281/2023003 ML23286A0372023-10-13013 October 2023 Annual Submittal of Technical Specifications Bases Changes Pursuant to Technical Specification 6.4.J ML23285A0922023-10-12012 October 2023 Inservice Testing Program for Pumps and Valves Sixth Interval Update and Associated Relief and Alternative Requests ML23277A1172023-10-0303 October 2023 Operator Licensing Examination Approval 05000280/2023301 and 05000281/2023301 ML23230A0502023-10-0202 October 2023 5 of the Quality Assurance Topical Report - Review of Program Changes ML23256A2672023-09-21021 September 2023 Review of the Fall 2022 Steam Generator Tube Inspection Report ML23244A2352023-09-18018 September 2023 Request to Use a Subsequent Edition of the ASME Code, Section XI ML23230A0012023-09-15015 September 2023 Request to Use a Provision of a Previous Edition of the ASME Boiler and Pressure Vessel Code, Section XI, for Non-Destructive Examinations IR 05000280/20220042023-09-0101 September 2023 Reissue - Surry Power Station - Integrated Inspection Report 05000280/2022004 and 05000281/2022004 ML23244A0142023-08-30030 August 2023 Inservice Inspection Owner'S Activity Report IR 05000280/20230052023-08-23023 August 2023 Updated Inspection Plan for Surry Power Station, Units 1 and 2 (Report 05000280/2023005 and 05000281/2023005) ML23226A1862023-08-10010 August 2023 Proposed License Amendment Request - Reclassification of Regulatory Guide 1.97 Variable for Low Head Safety Injection Flow Instrumentation ML23220A1492023-08-0707 August 2023 Independent Spent Fuel Storage Installation - Submittal of Cask Registrations for Spent Fuel Storage ML23220A1482023-08-0707 August 2023 Proposed Emergency Plan Revision - Relocation of the Technical Support Center (TSC) Response to Request for Additional Information IR 05000280/20230022023-08-0404 August 2023 Integrated Inspection Report 05000280/2023002 and 05000281/2023002 ML23208A0922023-07-26026 July 2023 Request for Approval of Appendix F of Fleet Report DOM-NAF-2-P Qualification of Framatome ORFEO-GAIA and OORFE-NMGRID CHF Correlations in the Dominion Energy Vipre-D Computer Code Response ML23207A1102023-07-26026 July 2023 NRC Regulatory Issues Summary 2023-01 Preparation and Scheduling of Operator Licensing Examinations ML23198A0322023-07-18018 July 2023 Regulatory Audit Report Regarding Review of License Amendment to Modify Emergency Plan Staff Augmentation Times ML23193A9382023-07-18018 July 2023 Closeout of Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors ML23173A0602023-07-11011 July 2023 Audit Summary for License Amendment Request Revision of the Emergency Plan to Support Relocation of the Technical Support Center ML23136B1392023-06-29029 June 2023 Issuance of Amendment No. 313 Administrative Changes to Subsequent Renewed Operating Licenses and Technical Specifications ML23178A1682023-06-26026 June 2023 2022 Annual Report of Emergency Core Cooling System (ECCS) Model Changes Pursuant to the Requirements of 10 CFR 50.46 ML23152A0432023-06-22022 June 2023 Audit Plan License Amendment Requests to Change Emergency Plan Staff Augmentation Times ML23153A1732023-06-16016 June 2023 Correction to Amendment Nos. 346 & 286 Millstone, 294 & 277 North Anna, 311 & 311 Surry, and 225 Summer to Revise Technical Specifications to Adopt TSTF-554,Rev Reactor Coolant Leakage Requirement ML23163A2352023-06-12012 June 2023 Request to Use a Later Edition of the ASME Boiler and Pressure Vessel Code, Section XI, for the SPS Sixth Inservice Inspection (Isi) Intervals and VCSNS Fifth ISI Interval ML23151A6612023-05-31031 May 2023 ES-2.1-1, Surry 2023-301 Corporate Notification Letter (Revised) ML23167B0072023-05-31031 May 2023 Proposed Emergency Plan Revision - Relocation of the Technical Support Center (TSC) Supplemental Information - LOCA Dose Calculation Summary ML23117A0952023-05-10010 May 2023 Audit Plan License Amendment Request to Support Relocation of the Technical Support Center ML23130A3742023-05-10010 May 2023 Request to Delay NRC Intial Licensing Examination 2024-02-06
[Table view] |
Text
May 31, 2006Mr. David A. Christian Senior Vice President and Chief Nuclear Officer Virginia Electric and Power Company Innsbrook Technical Center 5000 Dominion Boulevard Glen Allen, VA 23060-6711
SUBJECT:
SURRY POWER STATION, UNIT NO. 1 (SURRY 1 ) - CORRECTION TORELIEF REQUESTS PRT-07 AND PRT-08 (TAC NOS. MC6690 AND MC6707)
Dear Mr. Christian:
On March 28, 2006, the Nuclear Regulatory Commission (NRC) issued Relief RequestsPRT-07 and PRT-08 for Surry 1. These reliefs were in response to your application dated April 11, 2005. By letter dated April 27, 2006, you informed the NRC that the safety evaluations (SEs) for bothrelief requests contained a discrepancy. Your letter stated that these SEs provided the datesfor the third 10-year inservice inspection interval (ISI) at Surry 2, instead of the dates for the third 10-year ISI at Surry 1. The corrected pages for these SEs are enclosed with this letter.
The revisions to the SEs are identified by lines in the margin.Sincerely,/RA/Stephen R. Monarque, Project Manager Plant Licensing Branch II-1 Division of Operating Reactor Licensing Office of Nuclear Reactor RegulationDocket No. 50-280
Enclosure:
Safety Evaluation cc w/encl: See next page
ML061510365 NRR-028OFFICENRR/LPL2-1/PMNRR/LPL2-1/LANRR/LPL2-1/BCNAMESMonarque:srmMO'BrienEMarinos DATE5/17/065/18/065/26/06 listed therein. The ASME Code of record for the Surry 1 ISI program is the 1989 edition ofASME Code,Section XI. The licensee requested relief for the third 10-year ISI interval at Surry 1, which began on October 14, 1993, and ended on December 31, 2004.
l
3.0TECHNICAL EVALUATION
3.1ASME Code,Section XI Requirement The 1989 edition of ASME Code,Section XI, Article IWB-2500 requires that components beexamined and tested as specified in Table IWB-2500-1. Table IWB-2500-1, examination category B-A, item number B1.11 requires a volumetric examination of the RV circumferential shell welds once each 10-year ISI interval with essentially 100-percent volumetric coverage of the examination volume cross section specified in Figure IWB-2500-1 of ASME Code,Section XI, for essentially 100-percent of the weld length.3.2Component for Which Relief is RequestedCategory Item Description B-A B1.11 RV Circumferential Shell WeldsThe licensee has specifically requested relief for Circumferential Shell Weld 1-04 at Surry 1. This weld adjoins the RV shell with the lower vessel head.3.3Licensee's Basis for Relief Request The ultrasonic examination of the reactor pressure vessel circumferential shellweld is conducted in accordance with techniques qualified by demonstration for Appendix VIII, Supplements 4 and 6 of the 1995-96 Addenda of ASME [Code],Section XI.There are four core support lugs located at 0 degree, 90 degree, 180 degree,and 270 degree [azimuth] positions [at] the vessel inside surface just above the
[circumferential shell] weld which restrict[s] complete coverage of the required examination volume. The ultrasonic examination of this weld was performed by scanning the accessible scan surfaces between the support lugs and below the support lugs. Figure 1 [in the licensee's submittal] shows the general configuration of the reactor vessel and location of weld 1-04. Figures 2 and 3 [in the licensee's submittal] show the ultrasonic scanning boundaries for this weld with the restrictions due to the core support lugs. The size of the ultrasonic manipulator end effector limits how close the individual transducers can be positioned to the support lugs while scanning. The proximity of the end effector to the support lugs limits the amount of coverage obtained with each of the qualified transducers. Table 1 [in the licensee's submittal] provides the breakdown of percent [of] coverage of the required examination volume by scan direction and transducer. The achieved coverage of the required examinationvolume applying the qualified techniques is 73.4 [percent]. Relief Request PRT-08 lMay 26, 2006 l subject to the limitations and modifications listed therein. The ASME Code of record for theSurry 1 ISI program is the 1989 edition of ASME Code,Section XI. The licensee requested relief for the third 10-year ISI interval at Surry 1, which began on October 14, 1993, and ended lon December 31, 2004.
l
3.0TECHNICAL EVALUATION
3.1ASME Code,Section XI Requirement The 1989 edition of ASME Code,Section XI, Article IWB-2500, requires that components beexamined and tested as specified in Table IWB-2500-1. Table IWB-2500-1, examination category B-A, Item Number B1.30, requires a volumetric examination of the RV shell-to-flange weld once each 10-year ISI interval, with essentially 100-percent volumetric coverage of the examination volume specified in Figure IWB-2500-4 of ASME Code,Section XI.3.2Component for Which Relief is Requested Category Item Description B-A B1.30 RV Shell-to-Flange Weld 3.3Licensee's Basis for Relief Request The ultrasonic examination of the reactor vessel shell-to-flange weld wasperformed using a combination of manual and remote automated ultrasonic examination techniques. The manual examination was applied from the flange surface with techniques in accordance with the requirements of ASME Section V, Article 4. The remote automated ultrasonic examinations were performed from the vessel shell inside surface using techniques qualified by demonstration for Appendix VIII, Supplements 4 and 6 of the 1995-1996 Addenda of ASME Section XI as allowed by approved relief request SR-030 (NRC letter datedOctober 16, 2004). These automated techniques are noted to produce more accurate, reliable and repeatable procedures of examinations than the standard
[ASME Code] Section V techniques previously used.Figure 1 [of the licensee's submittal] shows the reactor vessel and associatedwelds. Figures 2 and 3 [of the licensee's submittal] illustrate the weld profile andshow scan orientation and directions. Coverage of the examination volume is obtained by combining the manual examination performed from the flange surface with the automated coverage obtained from the vessel shell surface. The examination performed from the flange surface provides examination coverage with the ultrasonic sound beam directed essentially normal to the weld axis. Coverage from the flange provides coverage of the examination volume in one beam direction, perpendicular to the weld axis. The ASME Section XI, Appendix VIII, Supplements 4 and 6 techniques are applied from the vesselinside surface, scanning in four directions to the extent possible. Due to the surface geometry of the flange, the ability to scan the necessary areas to providecomplete coverage of the examination volume in four directions is limited. The examination tool end effector, which holds the ultrasonic transducers, is not able to maintain the necessary surface contact on the non-parallel surface of theRelief Request PRT-07 lMay 26, 2006 l
Surry Power Station, Units 1 & 2 cc:Ms. Lillian M. Cuoco, Esq.Senior Counsel Dominion Resources Services, Inc.
Building 475, 5th Floor Rope Ferry Road Waterford, Connecticut 06385Mr. Donald E. JerniganSite Vice President Surry Power Station Virginia Electric and Power Company 5570 Hog Island Road Surry, Virginia 23883-0315Senior Resident InspectorSurry Power Station U. S. Nuclear Regulatory Commission 5850 Hog Island Road Surry, Virginia 23883ChairmanBoard of Supervisors of Surry County Surry County Courthouse Surry, Virginia 23683Dr. W. T. LoughVirginia State Corporation Commission Division of Energy Regulation Post Office Box 1197 Richmond, Virginia 23218Dr. Robert B. Stroube, MD, MPHState Health Commissioner Office of the Commissioner Virginia Department of Health Post Office Box 2448 Richmond, Virginia 23218Office of the Attorney GeneralCommonwealth of Virginia 900 East Main Street Richmond, Virginia 23219Mr. Chris L. Funderburk, DirectorNuclear Licensing & Operations Support Dominion Resources Services, Inc.
Innsbrook Technical Center 5000 Dominion Blvd.
Glen Allen, Virginia 23060-6711