Line 1: |
Line 1: |
| #REDIRECT [[JAFP-13-0148, James a FitzPatrick - Registration of Spent Fuel Cask Use]] | | {{Adams |
| | | number = ML13325B097 |
| | | issue date = 11/21/2013 |
| | | title = James a FitzPatrick - Registration of Spent Fuel Cask Use |
| | | author name = Adner C M |
| | | author affiliation = Entergy Nuclear Northeast, Entergy Nuclear Operations, Inc |
| | | addressee name = |
| | | addressee affiliation = NRC/Document Control Desk, NRC/NRR |
| | | docket = 05000333, 07200012, 07201014 |
| | | license number = DPR-059 |
| | | contact person = |
| | | case reference number = JAFP-13-0148 |
| | | document type = Letter |
| | | page count = 2 |
| | }} |
| | |
| | =Text= |
| | {{#Wiki_filter:JAFP-13-0148 November 21, 2013 |
| | |
| | U.S. Nuclear Regulatory Commission |
| | |
| | ATTN: Document Control Desk Washington, DC 20555 |
| | |
| | ==Subject:== |
| | Registration of Spent Fuel Cask Use James A FitzPatrick Nuclear Power Plant Docket No.s 50-333 and 72-12 License No. DPR-59 |
| | |
| | ==Dear Sir or Madam:== |
| | |
| | Entergy Nuclear Operations, Inc. (ENO), operates the James A. FitzPatrick (JAF) Nuclear Power Plant Independent Spent Fuel Storage Installation (ISFSI) in accordance with the general license provisions of 10 CFR 72.210. The conditions of 10 CFR 72.212(b)(2) include the registration of a spent fuel cask within 30 days of using a cask for storage of spent nuclear fuel. |
| | Accordingly, JAF provides the following registration information associated with three (3) HI-STORM 100 spent fuel cask systems that were recently placed into storage in the JAF ISFSI. |
| | |
| | Cask Certificate: 72-1014 Amendment 5 Cask Model: HI-STORM 100S Version B MPC Serial Number: 415 Overpack Serial Number: 690 Number of Fuel Bundles: 68 Placed in Service: 10/26/2013 Cask Certificate: 72-1014 Amendment 5 Cask Model: HI-STORM 100S Version B MPC Serial Number: 416 Overpack Serial Number: 691 Number of Fuel Bundles: 68 Placed in Service: 11/2/2013 |
| | |
| | Cask Certificate: 72-1014 Amendment 5 Cask Model: HI-STORM 100S Version B MPC Serial Number: 417 Overpack Serial Number: 692 Number of Fuel Bundles: 68 Placed in Service: 11/8/2013 Entergy Nuclear NortheastEntergy Nuclear Operations, Inc. James A. FitzPatrick NPP P.O. Box 110 Lycoming, NY 13093 Tel 315-342-3840 |
| | |
| | Chris M. Adner Regulatory Assurance Manager - JAF JAFP-13-0 148 Page 2 of 2 Total Cask Systems stored in the JAF ISFSI: Eighteen (18) HI-STORM 100 Cask Systems This letter contains no new commitments. |
| | Should you have any questions or require further information, please contact me, at (315) 349-6766. |
| | Chris M. Adner Regulatory Assurance Manager JP/mh cc: Director, Spent Fuel Project Office Office of Nuclear Material and Safeguards U. S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 NRC Regional Administrator NRC Resident Inspector Mr. Mohan Thadani, Senior Project Manager Ms. Bridget Frymire, NYSPSC Mr. Francis J. Murray Jr., President NYSERDA}} |
|
---|
Category:Letter
MONTHYEARIR 05000333/20240032024-11-12012 November 2024 Integrated Inspection Report 05000333/2024003 ML24317A1432024-11-0404 November 2024 Constellation Energy Generation, LLC, 2024 Annual Report - Guarantees of Payment of Deferred Premiums ML24309A2872024-11-0404 November 2024 International, HI-STORM 100 Amendment 19 Responses to Requests for Additional Information JAFP-24-0055, Response to Request for Additional Information for License Amendment Request to Add Temporary Change to TS 3.3.2.1, Condition C, Control Rod Block Instrumentation2024-10-29029 October 2024 Response to Request for Additional Information for License Amendment Request to Add Temporary Change to TS 3.3.2.1, Condition C, Control Rod Block Instrumentation IR 05000333/20240902024-10-29029 October 2024 Final Significance Determination of a White Finding with Assessment Follow-Up and Notice of Violation; Inspection Report 05000333/2024090 IR 05000333/20244022024-10-28028 October 2024 Material Control and Accounting Program Inspection Report 05000333/2024402 (Cover Letter Only) ML24276A1332024-10-17017 October 2024 Issuance of Amendment No. 357 Revise Technical Specifications to Adopt TSTF-529, Clarify Use and Application Rules, Revision-4, and Administrative Changes AEP-NRC-2024-80, Independent Spent Fuel Storage Installation Registration of Dry Spent Fuel Storage Cask2024-10-15015 October 2024 Independent Spent Fuel Storage Installation Registration of Dry Spent Fuel Storage Cask ML24282B0302024-10-11011 October 2024 Project Manager Assignment RS-24-093, Response to Request for Additional Information - Alternative Request to Utilize Code Case OMN-32, Alternative Requirements for Range and Accuracy of Pressure, Flow, and Differential Pressure Instruments Used in Pump Tests2024-10-10010 October 2024 Response to Request for Additional Information - Alternative Request to Utilize Code Case OMN-32, Alternative Requirements for Range and Accuracy of Pressure, Flow, and Differential Pressure Instruments Used in Pump Tests ML24274A3032024-10-0909 October 2024 Amendment 19 to Certificate of Compliance 1014 for Hi-Storm 100 Multi-Purpose Canister Storage System Request for Additional Information ML24207A0192024-10-0909 October 2024 SE Addendum Related to the License Amendment No. 338 for Implementation of the Alternative Source Term (DPO-2021-001) ML24240A1182024-10-0808 October 2024 0 Issuance Letter Amendment 18 to Renewed Certificate of Compliance No. 1014 for the HI-STORM 100 Cask System SVP-24-059, Correction to Registration of Use of Casks to Store Spent Fuel2024-10-0404 October 2024 Correction to Registration of Use of Casks to Store Spent Fuel ML24275A2442024-10-0303 October 2024 Reassignment of the U.S. Nuclear Regulatory Commission Branch Chief, Division of Operating Reactor Licensing JAFP-24-0051, Reply to Preliminary White Finding and Apparent Violation in NRC Inspection Report 05000333/2024011; EA-24-0882024-10-0303 October 2024 Reply to Preliminary White Finding and Apparent Violation in NRC Inspection Report 05000333/2024011; EA-24-088 ML24270A0742024-09-30030 September 2024 Individual Notice of Consideration of Issuance of Amendments to Renewed Facility Operating Licenses, Proposed No Significant Hazards Consideration Determination, & Opportunity for a Hearing (EPID L-2024-LLA-0134) - LTR AEP-NRC-2024-79, Unit 2, Independent Spent Fuel Storage Installation - Registration of Dry Spent Storage Cask2024-09-26026 September 2024 Unit 2, Independent Spent Fuel Storage Installation - Registration of Dry Spent Storage Cask ML24270A1452024-09-26026 September 2024 Notice of Enforcement Discretion for James A. Fitzpatrick Nuclear Power Plant JAFP-24-0046, Request for Enforcement Discretion for Technical Specification (TS) 3.3.2.1 Control Rod Block Instrumentation2024-09-25025 September 2024 Request for Enforcement Discretion for Technical Specification (TS) 3.3.2.1 Control Rod Block Instrumentation JAFP-24-0047, License Amendment Request – Temporary Addition to TS 3.3.2.1 Condition C, Control Rod Block Instrumentation to Support Upgrade to Rod Worth Minimizer Software2024-09-25025 September 2024 License Amendment Request – Temporary Addition to TS 3.3.2.1 Condition C, Control Rod Block Instrumentation to Support Upgrade to Rod Worth Minimizer Software JAFP-24-0045, Supplemental Information for License Amendment Request to Revise Technical Specifications to Adopt TSTF-529, Clarify Use and Application Rules, Revision 4, and Administrative Changes to the Technical Specifications2024-09-20020 September 2024 Supplemental Information for License Amendment Request to Revise Technical Specifications to Adopt TSTF-529, Clarify Use and Application Rules, Revision 4, and Administrative Changes to the Technical Specifications ML24263A2062024-09-19019 September 2024 Request for Exemption from Certain Requirements of 10 CFR 72.212 and 10 CFR 72.214 for LaSalle County Station - Holtec MPC-68MCBS IR 05000333/20240112024-09-19019 September 2024 Follow-up to Inspection Procedure 71153 Report 05000333/2024011 and Preliminary White Finding and Apparent Violation JAFP-24-0044, Core Operating Limits Report Cycle 272024-09-16016 September 2024 Core Operating Limits Report Cycle 27 NL-24-0351, – ISFSI - Registration of Spent Fuel Cask Use2024-09-13013 September 2024 – ISFSI - Registration of Spent Fuel Cask Use JAFP-24-0043, Revision to Commitment Relating to Resolution of Anchor Darling Double Disc Gate Valve Part 21 Issues2024-09-12012 September 2024 Revision to Commitment Relating to Resolution of Anchor Darling Double Disc Gate Valve Part 21 Issues 05000333/LER-2024-002, Reactor Protection System Electric Power Monitoring System Trip Caused Primary Containment Isolation2024-09-0404 September 2024 Reactor Protection System Electric Power Monitoring System Trip Caused Primary Containment Isolation ML24165A0382024-09-0404 September 2024 Issuance of Amendment No. 356 Update Fuel Handling Accident Analysis IR 05000333/20240052024-08-29029 August 2024 Updated Inspection Plan for James A. Fitzpatrick Nuclear Power Plant (Report 05000333/2024005) 05000333/LER-2024-001-01, EDG Lube Oil Check Valve Bonnet Cap Leak Due to Failed Gasket2024-08-21021 August 2024 EDG Lube Oil Check Valve Bonnet Cap Leak Due to Failed Gasket ML24222A6772024-08-0909 August 2024 Response to Request for Additional Information for Application to Revise Technical Specifications to Adopt TSTF-591-A, Revise Risk Informed Completion Time (RICT) Program Revision 0 and Revise 10 CFR 50.69 License Condition ML24222A8592024-08-0909 August 2024 International - HI-STORM 100 Multipurpose Canister Storage System Amendment 19 Request ML24221A2702024-08-0808 August 2024 Unit 2 Independent Spent Fuel Storage Installation - Registration of Dry Spent Fuel Storage Cask IR 05000333/20240022024-08-0707 August 2024 Integrated Inspection Report 05000333/2024002 AEP-NRC-2024-62, Unit 2, Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Cask2024-08-0707 August 2024 Unit 2, Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Cask JAFP-24-0034, 10 CFR 50.46 Annual Report2024-07-31031 July 2024 10 CFR 50.46 Annual Report SVP-24-048, Registration of Use of Casks to Store Spent Fuel2024-07-31031 July 2024 Registration of Use of Casks to Store Spent Fuel ML24208A0492024-07-30030 July 2024 Notice of Consideration of Issuance of Amendments to Facility Operating Licenses and Proposed No Significant Hazards Consideration Determination (Letter) ML24178A4312024-07-29029 July 2024 Issuance of Certificate of Compliance No. 1014, Amendment No. 16 for the HI-STORM 100 Cask System, Cover Letter JAFP-24-0036, Supplement to License Amendment Request to Update the Technical Specification Bases to Change the Fuel Handling Accident Analysis2024-07-29029 July 2024 Supplement to License Amendment Request to Update the Technical Specification Bases to Change the Fuel Handling Accident Analysis JAFP-24-0033, Response to Request for Information Pertaining to a Licensed Operator Positive Fitness-For-Duty Test2024-07-23023 July 2024 Response to Request for Information Pertaining to a Licensed Operator Positive Fitness-For-Duty Test IR 05000333/20244032024-07-18018 July 2024 Biennial Problem Identification and Resolution Inspection Report 05000333/2024403 (Cover Letter Only) IR 05000333/20244012024-07-15015 July 2024 Security Baseline Inspection 05000333/2024401 RS-24-070, Independent Spent Fuel Storage Installation, Nine Mile Point, Units 1 and 2, Quad Cities, Units 1 and 2, R. E. Ginna - Nuclear Radiological Emergency Plan Document Revisions2024-07-12012 July 2024 Independent Spent Fuel Storage Installation, Nine Mile Point, Units 1 and 2, Quad Cities, Units 1 and 2, R. E. Ginna - Nuclear Radiological Emergency Plan Document Revisions ML24190A1932024-07-0909 July 2024 Correction Letter of Amendment No. 355 Revise Technical Specifications Section 3.4.3.1, Safety Relief Valves Setpoint Lower Tolerance IR 05000333/20240102024-07-0808 July 2024 Commercial Grade Dedication Inspection Report 05000333/2024010 AEP-NRC-2024-56, Unit 2, Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Cask2024-07-0808 July 2024 Unit 2, Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Cask ML24184A1662024-07-0303 July 2024 Senior Reactor and Reactor Operator Initial License Examinations ML24136A1162024-06-26026 June 2024 Issuance of Amendment No. 355 Revise Technical Specifications Section 3.4.3.1, Safety Relief Valves Setpoint Lower Tolerance 2024-09-04
[Table view] |
Text
JAFP-13-0148 November 21, 2013
U.S. Nuclear Regulatory Commission
ATTN: Document Control Desk Washington, DC 20555
Subject:
Registration of Spent Fuel Cask Use James A FitzPatrick Nuclear Power Plant Docket No.s 50-333 and 72-12 License No. DPR-59
Dear Sir or Madam:
Entergy Nuclear Operations, Inc. (ENO), operates the James A. FitzPatrick (JAF) Nuclear Power Plant Independent Spent Fuel Storage Installation (ISFSI) in accordance with the general license provisions of 10 CFR 72.210. The conditions of 10 CFR 72.212(b)(2) include the registration of a spent fuel cask within 30 days of using a cask for storage of spent nuclear fuel.
Accordingly, JAF provides the following registration information associated with three (3) HI-STORM 100 spent fuel cask systems that were recently placed into storage in the JAF ISFSI.
Cask Certificate: 72-1014 Amendment 5 Cask Model: HI-STORM 100S Version B MPC Serial Number: 415 Overpack Serial Number: 690 Number of Fuel Bundles: 68 Placed in Service: 10/26/2013 Cask Certificate: 72-1014 Amendment 5 Cask Model: HI-STORM 100S Version B MPC Serial Number: 416 Overpack Serial Number: 691 Number of Fuel Bundles: 68 Placed in Service: 11/2/2013
Cask Certificate: 72-1014 Amendment 5 Cask Model: HI-STORM 100S Version B MPC Serial Number: 417 Overpack Serial Number: 692 Number of Fuel Bundles: 68 Placed in Service: 11/8/2013 Entergy Nuclear NortheastEntergy Nuclear Operations, Inc. James A. FitzPatrick NPP P.O. Box 110 Lycoming, NY 13093 Tel 315-342-3840
Chris M. Adner Regulatory Assurance Manager - JAF JAFP-13-0 148 Page 2 of 2 Total Cask Systems stored in the JAF ISFSI: Eighteen (18) HI-STORM 100 Cask Systems This letter contains no new commitments.
Should you have any questions or require further information, please contact me, at (315) 349-6766.
Chris M. Adner Regulatory Assurance Manager JP/mh cc: Director, Spent Fuel Project Office Office of Nuclear Material and Safeguards U. S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 NRC Regional Administrator NRC Resident Inspector Mr. Mohan Thadani, Senior Project Manager Ms. Bridget Frymire, NYSPSC Mr. Francis J. Murray Jr., President NYSERDA