TAC:M82809
From kanterella
Jump to navigation
Jump to search
Request for: Approved, Closed | |
From | |
MONTHYEARML20134H7621996-11-0606 November 1996
[table view]Proposed Tech Specs 3.4.6.1 Re Reactor Coolant Leakage Detection Systems ML20137W3311997-04-17017 April 1997 Summary of 970407 Meeting W/Util & Transco Products,Inc Re Versawrap,New Electrical Raceway Firewrap Sys.Attachment 1 Describes Components of Typical Veraswrap Barrier & Attachment 2 Re Transco Products,Inc Test Procedure Encl ML20141B4751997-05-0909 May 1997 Forwards RAI Re Util 961106 Response to GL 92-08, Thermo- Lag 330-1 Fire Barriers. NRC Identified Number of Open Issues & Concerns Requiring Clarification.Response Requested within 60 Days of Ltr Date ML20140H9181997-05-0909 May 1997 Trip Rept of 970410-11 Visit to Ul to Observe full-scale Fire Endurance Test of 1 & 3 Hour Versawrap Fire Barrier Sys.List of Participants Encl ML20141A9341997-05-12012 May 1997 Responds to Util Responding to NRC RAI Re GL 92-08, Thermo-Lag 330-1 Fire Barriers. Encl Contractor Rept Identified Number of Open Issues & Concerns Requiring Clarification ML20141A8601997-05-12012 May 1997 Forwards RAI Re GL 92-08, Thermo-Lag 330-1 Fire Barriers. NRC Staff Reviewed & Identified Number of Open Issues & Concerns Requiring Clarification ML20141B6211997-05-13013 May 1997 Forwards RAI Re GL 92-08, Thermo-Lag 330-1 Fire Barriers, for Plant,Units 1 & 2 Re Ampacity Derating Issues.Technical Rept Encl ML20140F6731997-06-10010 June 1997 Forwards Request for Addl Info Re 970331 Response to NRC GL 92-08 for Plant Thermo-Lag Related Ampacity Derating Issues.Snl Ltr Rept Also Encl RBG-43994, Ack Receipt of NRC RAI Ltr Re Thermo-Lag-Related Ampacity Derating at River Bend Station.Draft Calculations Provided to Support Plant Response & Resolution of Associated Questions1997-06-16016 June 1997 Ack Receipt of NRC RAI Ltr Re Thermo-Lag-Related Ampacity Derating at River Bend Station.Draft Calculations Provided to Support Plant Response & Resolution of Associated Questions ML20149E0881997-07-0909 July 1997 Forwards Request for Addl Info Re Thermo-Lag Related Ampacity Derating Issues for Byron & Braidwood Stations Re GL 92-08 ML20217J5661997-08-11011 August 1997 Informs of Completion of Licensing Action for GL 92-08, Thermo-Lag 330-1 Fire Barriers. Requests Notification in Writing If Schedule or Resolution Plans Described in Submittal Change RBG-44186, Informs That Detailed Response to NRC RAI & Final Calculations Re Thermo-Lag Related Ampacity Derating,Will Be Submitted by 9709261997-08-28028 August 1997 Informs That Detailed Response to NRC RAI & Final Calculations Re Thermo-Lag Related Ampacity Derating,Will Be Submitted by 970926 ML20211J4861997-10-0202 October 1997 Discusses Completion of Licensing Action for GL 92-08, Thermo-Lag 330-1 Fire Barriers, Dtd 921217,for Plant ML20199H6641997-11-14014 November 1997 Forwards Request for Addl Info Re 970324 Response to NRC RAI Re GL 92-08, Thermo-Lag 330-1 Fire Barriers, for Peach Bottom & Limerick.Requests Response within Sixty Days to Support Review Schedule RBG-44325, Notifies That Actions Associated W/Resolution of Thermo-Lag Issues at Plant Completed,Per GL 92-08.First Phase Completed by Development of Revised Safe Shutdown Analysis1997-11-25025 November 1997 Notifies That Actions Associated W/Resolution of Thermo-Lag Issues at Plant Completed,Per GL 92-08.First Phase Completed by Development of Revised Safe Shutdown Analysis ML20249B7801998-06-19019 June 1998 Forwards Request for Addl Info Related to Thermo-Lag Fire Barriers & GL 92-08 for Grand Gulf Nuclear Station,Unit 1 ML20199H5821999-01-20020 January 1999 Forwards SE Re Ampacity Derating Issues Due to Application of Thermo-Lag Fire Barrier Matl at Plant ML20202E4631999-01-25025 January 1999 Provides Confirmation That Corrective Actions Re Thermo-Lag 330-1 Issues,Per GL 92-08,have Been Completed.Ltr Also Confirms Completion of Actions Required by Confirmatory Order Modifying License for Plant,Issued by NRC on 980622 ML20202B3671999-01-26026 January 1999 Forwards Safety Evaluation Addressing Thermo-Lag Related Ampacity Derating Issues & Technical Evaluation of Duane Arnold Energy Ctr Analysis of Ampacity Loads for Fire Barrier Clad Power Cables. Technical Evaluation Rept Encl 1997-06-10 |
Retrieved from "https://kanterella.com/w/index.php?title=TAC:M82809&oldid=3422219"