Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML18038A304 +
- ML17328A717 +
- ML17328A715 +
- ML17305A872 +
- ML18033B301 +
- ML18033B299 +
- ML18095A210 +
- ML18095A205 +
- ML13309A915 +
- ML100331228 +
- ML20043C077 +
- ML20043B271 +
- ML20043B250 +
- ML20043B150 +
- ML20043A921 +
- ML20043A902 +
- ST-HL-AE-3454, Clarifies Operation of Telephone Autodialer Sys,As Part of Prompt Notification Sys.Autodialer Sys,As Currently Configured,Can Autodial & Deliver Prerecorded Message to Residents at Rate of Approx 20 Calls Per Minute +
- ML20043A835 +
- ML20043A666 +
- ML20043A655 +
- RBG-32834, Forwards Authorization of Util Board of Directors for Tf Plunkett & Wh Odell to Sign Ltrs to NRC Transmitting Amends to OL or Responses to Insp Repts +
- ML20043A409 +
- ML20043A408 +
- ML20043A334 +
- ML20043A332 +
- ML20043A236 +
- ML20043A122 +
- ML20042H067 +
- ML20042H065 +
- ML20042H061 +
- ML20042H013 +
- ML20261E262 +
- ML20058K182 +
- ML23152A239 +
- ML20117Q032 +
- 05000457/LER-1990-005-08, :on 900416,diesel Generator 2A Speed Oscillations Occurred Due to Defective Resistor.Caused by Failure of One Dropping Resistor in Governor Unit.Resistors Replaced +
- BSEP-90-0382, Forwards Corrected Graph for 900531 Integrated Action Plan Status Rept Illustrating Level 1 Items Projected as of 900331 +
- ML20043B743 +
- ML20043A829 +
- 05000445/LER-1990-006, :on 900412,P-6 Permissive Signal Received & Source Range Flux Doubling (Srfd) Actuation Occurred.Caused by Inadvertent Reset of Srfd Block.Integrated Plant Operations Procedures Changed +
- 05000321/LER-1990-006, :on 900418,discovered That Wiring Error Existed in Junction Box Leading to Strip Recorder That Resulted in Inadequate Tech Spec Surveillance.Caused by Personnel Error. Wiring Error Corrected & Personnel Counseled +
- 05000457/LER-1990-004-08, :on 900416,diesel Generator 2A Speed Oscillated Prior to Maint Teardown.Caused by Component Failure.Resistors Replaced & Placed on 3-yr Replacement Frequency +
- 05000327/LER-1990-007-01, :on 900413,discovered That Tech Spec Surveillance Requirement Not Performed within Required Interval.Caused by Personnel Error.Surveillance Successfully Performed Since Missed +
- 05000317/LER-1990-013, :on 900413,determined That Axial Shape Index Channels Out of Spec & Inoperable.Caused by Inadequate Understanding of Design Basis for Excore/Incore Comparison. Design Basis for Excore/Incore Improved +
- 05000277/LER-1990-007-02, :on 900412,evaluation Involving Seismic Qualification Performed Due to Postulated Failure of Condensate & Vacuum Pumps During Design Seismic Events. Caused by Design Oversight.Program Updated +
- ELV-01632, Forwards Summary of Corrective Actions for 900320 Site Area Emergency Due to Loss of Offsite Power Concurrent W/Loss of Onsite Emergency Diesel Generator Capability.Truck Driver Disciplined for Lack of Attention +
- 05000321/LER-1990-007-01, :on 900419,determined That Errors in Calculations for Measuring Feedwater Flow Resulted in Nonconservative Calibr of Flow Transmitters.Caused by Error in Design Calculation.Transmitters Recalibr +
- 05000328/LER-1990-009, :on 900404,lower Containment Radiation Monitor Found Inoperable & Lower Containment Atmosphere Aligned to Upper Containment Radiation Monitor During Sampling.Caused by Personnel Error.Chemistry Training Revised +
- 05000327/LER-1990-006-01, :on 900414,auxiliary Bldg Isolation Occurred from Spent Fuel Pit Area Radiation Monitors 0-RM-90-102 & 103.Caused by Personnel Error.Training Ltr Issued to Instrument Mechanics & Operations Personnel +
- ML20042H026 +