- 05000311/LER-1991-002, :on 910116,radiation Monitoring Sys Channel Failed.Caused by Equipment Design Concerns.Sys Design Mods Under Investigation.Channel Inspected & Repaired +
- ML20029C190 +
- ML20029B636 +
- ML20029B633 +
- ML20029A445 +
- ML20029A442 +
- ML20029A343 +
- ML20070L667 +
- ML20066K115 +
- ML20066J524 +
- ML20066H692 +
- ML20066H597 +
- ML20066H510 +
- ML20066H258 +
- ML20066H196 +
- ML20066H146 +
- ML20066H139 +
- ML20066G518 +
- ML20066G090 +
- ML20081E977 +
- ML20073H231 +
- ML20066H670 +
- ML20217B354 +
- U-601795, Responds to NRC Re Violations Noted in Insp Rept 50-461/90-26.Corrective Actions:Procedure 1905.21 Re Restricted High Radiation Area Key Control Revised to Restrict Issuance of Keys to Radiation Protection Personnel +
- ELV-02530, Forwards Response to Unresolved Item Noted in Insp Repts 50-424/90-31 & 50-425/90-31 from Insp on 901210-14.Response Withheld +
- 2CAN029107, Submits Annual Rept for Activity of Primary Coolant for 1990.Primary Coolant Did Not Exceed Limits of Tech Spec 3.4.8 +
- HL-1470, Special Rept:On 901119,discrepancy Noted in Number of SRM & IRM Detectors During Inventory.Caused by Inadequate Recordkeeping Controls.Responsibility for Control & Accountability of Detectors Returned to Reactor Engineering +
- SNRC-1789, Forwards Request for Mod of SPDES Permit 0026344,reflecting Sale & Impending Transfer of Facility +
- ML20206Q707 +
- ML20206Q701 +
- ML20206Q674 +
- 05000259/LER-1990-021, :on 900927,hourly Fire Watch Could Not Enter a 4,160-volt Shutdown Board Room to Perform Visual Insp of Area in Violation of Tech Spec.Caused by Procedural Deficiency.Fire Protection Plan Revised +
- 05000317/LER-1990-030, :on 901204,cracks Found in Safety Injection Tank Nitrogen Vent Line Welds.Caused by Design Engineering Personnel error.CCI-126 Will Be Revised to Clarify Walkdown Requirements +
- 05000327/LER-1991-001-03, :on 910115,sequence Timers for Electrical Board Room & Main Control Room Air Handling Units Not Calibr at Required Frequency.Caused by Failure to Recognize Timers as within Scope of DG Surveillance Requirement +
- 05000260/LER-1991-001-02, :on 910116,unplanned Actuations of Various ESFs Occurred Due to Blown Fuse in Primary Containment Isolation Sys Logic Circuitry.Caused by Failure of GE Type CR120 Relay Due to Faulted Coil.Coils Replaced +
- 05000259/LER-1990-019, :on 901229,hourly Fire Watch Not Established When Instrument & Control Bus 1A Tripped Resulting in Loss of Power to Fire Detection Panels.Caused by Inadequate Procedure.Bus Returned to Svc +
- 05000317/LER-1990-030-01, :on 901204,cracks Found in Structural Weld at coulping-to-vent Line Junction During Insp of Nitrogen Vent Lines on Top of Tanks 11B & 12B.Caused by Personnel Error.Relief Valves Relocated +
- 05000424/LER-1990-024-01, :on 900807,Unit 2 Containment Isolation Valves Associated W/Train a Closed & Unit 1 Valves Opened for Testing.Caused by Procedural Inadequacy.Procedures Revised & Procedure Coordinator Informed +
- 05000461/LER-1991-016, :on 901129,secondary Containment Access to RHR a HX Room Breached.Caused by Lack of Knowledge of Requirements for Secondary Containment Integrity & Controlled Boundary Doors.Personnel Counseled +
- ML20045G132 +
- ML20034D161 +
- ELV-02478, Forwards Response to Notice of Violations Re Insp Repts 50-424/90-30 & 50-425/90-30 on 901124-1221.Corrective Actions:Complete Audit of Operations Drawing & Correction of Discrepancies Initiated & Completed in Dec 1990 +
- ML20029A458 +
- IR 05000416/1991001 +
- ML20029B001 +
- ML20029B122 +
- ML20029B333 +
- ML20155F992 +