ML20066H692

From kanterella
Jump to navigation Jump to search
Proposed Tech Specs Re Limiting Conditions for Operation & Surveillance Requirements for Auxiliary Feedwater Sys
ML20066H692
Person / Time
Site: North Anna  Dominion icon.png
Issue date: 02/14/1991
From:
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
Shared Package
ML20066H678 List:
References
NUDOCS 9102210241
Download: ML20066H692 (10)


Text

{{#Wiki_filter:. +e ;a.g y .avr. --ns y,, - + <+ e.. ,.,,.,> r M((g'h h. + i F.] / e pv - - v,-, g. m. ,m. vo, s m 1-a ( !,1 a u:d _: 4. en n 2- , [ ' m;[($, o.',, ' S.?![e C u;7, vo ,.a. [f OY\\+ $ i N' gh'. ,'_~) ? '] QK.' l1 d y s - i. p.T' jl 4H ,:1 + h.s/p. ;(m " w "5 m - c in y., R sg 1 g j-- te m,4: c g' 3 ,'r.IT ,i-ij.><i i n\\g, p r. :.,) H

m,

1 . 33 t %# ;l s i a) # M3 4 :^- ,h '... w ....su - w t hG , y)u, ) , s' j.., m i: U se w.. ..s -i,v : t'. a f: w %' + -y l., sa, te'r 4 g 1 f

1. -{ --

..I< 3-h ~.(1 g o / - '(;h g Yc. _ 'i. - -. t4 .? p + >M }. i' 'iQ 1 1 ,p L' ~ Proposed?TechnicalESpeeltication Change' 4 m '. North Anna Unit 11 '. c m ,~.) .^ 1

7

.N% h I. '.'n.' t f \\ q _[ 2 ':,$ '$(M < ,s,... o t ?,; < '; - ((z- - . -;i f, i s W.l.. ' ;O 1 f j' ?'4.w, %: Mi ' a# D t 3- . !. C., f 1 ). *

  • i g

l b w' j h - _.;, [' ( fs- - m,, < [ ..'.')-l .c 3 ; _ y 3,,.-

J.

-jg 5 4 r p. '}]-_ j:= s ' K1 o+

Virginia Electric > and _ Power 1 Company.-

ARe m tm. s T {' t 1 1 - 4 1 r h j, $ } _'i't s [5x t ..;>;,b Y' 1 ' 8 e '/ {.t< r 1 Y p.; 8 s... l _? E Q ' r...' Y h ff

[

. m,-,, 1 m; ( ',!e u,

PL ANT 'tYSIEMS AUXILIARY FEEDWATER SYSTEM L.IMITING CONDITION FOR OPERATION 3.7.1.2 At ' least three independent steam generato. auxiliary feedwater pumps and associated flow paths shall be OPERABLE with:

a. Two motor driven aaxiliary feedwater pumps, each capable of being powered from separate emergency busses, and
b. One steam turbine criven auxiliary feedwater pump capable of being powered from an OPER AblE steam supply system.

APf[,1CABILITY: MODES 1,2 and 3, ACTION:

a. With one auxiliary feedwater pmap inoperable, restore the equired auxiliary feedwater pumps to an OPERABLE slams within 72 hours or be in at least ilOT SHUTDOWN within the following 6 houre
b. With two auxiliary feedwater pumps inopetab'e be in at ast HC t' STANDBY within 6 hours and in HOT SHUTDOWN within the following 6 hours,
c. With three auxiliary feedwater pumps inoperable, immediately initiate corrective action to restore at least one auxiliary feedwater pump to OPERABLE status as soon as possible.

SURVEILLANCE REQUIREMENTS (Continued) 4.7.1.2 In addition to the requirements of Specification 4.0.5, each auxiliary feedwater pump, shall be demonstrated OPERABLE:

a. At least once per 31 days by;
l. Verifying that c;ch pump develops adequate discharge pressure and flow.

The acceptance criterion shall be consistent with Specification 4.0.5. The provisions of Specification 4.0.4 are not applicable to steam turbine driven pump testing. NORTH ANNA - UNIT 1 3/4 7-5 Amendment No.

.~g . 11 ANT SYST" J SURVEILLANCE REQUIREMENTS (Continued)

2. Verifying that each valve (manual, power operated or automatic) in the l flow path that is not locked, scaled, or otherwise secured in position, is in

. Its correct position,

b. At least once per 18 months during shutdown by:
1. Verifying - that each automatic valve in the flow path actuates to its correct position on an auxiliary feedwater actuation test signal.

2 Verifying that cach auxiliary feedwater pump starts automatically upon receipt of an auxiliary feedwater actuation test signal,

c. The auxiliary feedwater system shall be demonstrated OPERABLE prior to eniry into MODE 3 following each COLD SIIUTDOWN by performing a flew test to verify the normal flow path from the emergency condensate storage tank through each auxiliary feedwater pump to its associated steam genierator.

A 1 ( NORTil ANNA - UNIT 1 3/47-6 Amendment No.

+ Proposed Technical Specification Change North-Anna Unit 2 1 J e e.,. -s Virginia Electric and Power Company 2_________-__-__

n .-k c 3-Y iPLANT SVSTEMS' ' ' AUXILIARY FFEL 4 E i' STEM ; LIMITING CONDITION FOR OPERATION __ .g .s ...,....L 3.7.1.2 At.least. three independent - steam generator auxiliary feedwater pumps and l ~ associated flow. paths shall be OPERABLE with:

a. ' Two motor ' driven auxiliary feedwater pumps, each capable of being powered
from. separate, emergency busses..and
b. ' One steam turbine' driven auxiliary. feedwater pump capable of' being 1

powered from an OPERABLE steam supply system. . APPLICABILITY: MODES 1,'2 and 3. ACTION: a,- lWith Jone f auxiliary feedwater pump inoperable, restore the required auxiliary ' feedwater pumps lo. an' OPERABLE status within 72 hours or be in at least IIOT. c CSHUTDOWN*within ' the,following 6 hours. ) i --b,1With' two' auxiliary-feedwater pumps inoperable be in at least HOT. STANDBY within '6l hours and in HOT SHUTDOWN within the following 6 hours ] -.c. With threc. auxiliary feedwater pumps inoperable, immediately initia.te -corrective ~ .' action to restore at least one auxiliary feedwater pump to. OPERABLE status as soon as possible. ? SURVEILLA'NCE REQUIREMENTS (Continued) C4,7.1.2'. Ein Eaddition to the' requirements of Specification 4.0.5, each auxiliary feedwater pump -shall be -demonstrated OPERABLE: . a. At least once per 31 days by:

1. Verifying that each - pump develops adequate discharge pressure Land-flow.

i ' The acceptancer criterion shall be consistent with': Specification 4.0.5. The provisions 'of: Specification 4.0.4 are not applicable to ' steam ' turbine - 1 driven pump' testing. 'i i NORTH ANNA - UNIT 2 3/4 75 Amendment No. i .2-i w m

/ g l 4 4 r t. ' ';i f c s = ;, ,4 j. [ - PIjdNT SYSTEMS ;. o ~ .x 1 SURVEILLANCE REQUIREMENTS (Continued)- t J 'j f. s 3 2 iVerifyingithat.' each valve (manual, power operated ;or automatic) in the [ ' flow ; path that is not, iocked, scaled, or' otherwise secured in; position,'is in' t ? > its. l correct position. o .b. AtLleast once per 18 months.during. shutdown by: } ~ .J .F 1.- TVerifying; that ' cach automatic valve in the. flow. path actuates to = 'its. L z 3 correct position 1 onEan' auxiliary feedwater actuation test signal. w m 4 X.: . 2. ' Verifying that1 each ' auxiliary feedwater pump starts automatically upon . receipt of an.' auxiliary feedwater actuation test signal. -d s W. :. ' c. The_. auxiliary - feedwater system shall' be demonstrated ' OPERABLE - prior ~ -to -f - entryf nto MODE 3.following each COLD ' SHUTDOWN by performing a flow test i g /e m '.toi verify Jthe normal, flow path. from the - emergency condensate storage tank 4" ' through each auxiliary feedwater pump to its associated steam generator < .. i /} J . i v s a + k 9 3 l-

L

(.h :: }) L i r A. l e l-y P

l-y
y

_f f I y 1 ( l.- o I;~ L . N.' ORTH ANNA - UNIT 2 3/47-6 Amendment No. 1 = -

~ . ~. .. u a o,.., m . m. r J i f g 1 t -"I t.. ?

5.,,

,l i N ^ j n11 gi; 8' 2 D h. 'fyj# .j ' - t N. i f m r",' . iJ f j vl ,i.'. r 1 ;> [.g ' d.; y e

Attachment -3 p J T..,4 4

w n c (i}l}s x) - - J ? 1 [I [ ^ g P.;I n..j.. esrs, A b u'.g%. D 5 53..'*:- i - ( 3.s r

7 0

i YY h, ' Y .\\ U };,3

i ll-Q il_}

f' <

  • vu 1
w.,. f :.

. 7; , "- 4z_-fc a p { I '8 .,c m, 9 o i -< i - ._) (,,;y ' \\ 1,l i 'l t if(k e-5 s% '1 l

Vi,,

,. I'Q. ' h l'*y ) i (

^

f " M i { ; _; ~ W'f i ii?, o c, - %..s..r t. e n F, !M - Discussion:of Proposed Change x m North Anna: Units 1 Land 2 u, g , 3, 9, r s m, . n, m

o a

'b"1L l;.., ip '<d E b 4 u) pp'ji : y t W.j,, J j 5 s s, 5,,i .t - -u 'pgi' -)' 3: 1-p i ,1 f ; ' - Y+ L 4 ".'(' :,.'] I' 'l,; ' ' .i 1 e f t.., m' .. t, }'n vi. #. . ;i " '- 1 r3 i -,(: x ',l -.f.- s

g.

_i i. e 1 c r - f,, x: ^ {' s ,a w , '. ~ i' i s

ic l,{\\. c k

~ii .. s ,' f g u i d. ~I g ll t.h ']ql.. . {:7 4 4 t 1 ',.-( w, ,g .c. .^T',' 4'} f.(s } ;... ' iI ..g f-b_.. { -l _r l 1.:. $ h ', --} i .\\-. t v, r~ ltIV e ( ite-2r' t '} t e - Virginia. Electric and Power Company 1 4 a t hb + Y 'p 'y^ ci g.. ,s i; y, r p-s. L h i, 'd b I-l l' s I V .'. l :, l , ' l' h -1; i:1 - t, D:. 1 < + , C.., .J.. ,,...a. ,,,,l J-

) .s., 4 7 Discussion: of Proposed Changes 1

This change involves the acceptance criteria for the monthly auxiliary feedwater (AFW) pum'p test required by Specification 4.7.1.2.a. The current specification requires a specific _ discharge pressure and flow. The change deletes those specific values and

_ l will allow the ~ acceptable discharge pressure and flow rates to be establ!shed and l periodically reevaluated through our procedures.for ASME Section XI testing. l A previous proposed Technical Specification change was submitted to the NRC ' December 28J1989, which would have deleted the monthly testing requirement,.and4 only required a quarterly test in accordance with ASME Section XI. This new-proposed change will replace the previously submitted request. The auxiliary feidwater system is used to cool the steam generators, and therefore the l-reactor, when no, mal feedwater is lost or after a reactor trip. The AFW system includes - ? 1two motor driven and one turbine driven.pumpi Specification 3.7,1.2 requires all three o pumps to be OPERABLE in modes 1; 2 or 3 and Specification 4.7.1.2 requires monthly a testing on minimum flow recirculation, The pumps.are equ.j ped with minimum flow recirculation lines which include crifices p pjust large enough to ensure that the pumps will not overheat when run'with all other ' flow paths closed. This minimum flow was the basis for the original specification. ' NRC Bulletin 88-04 " Safety Related Pump Loss" identified concerns with hydraulic - , < m- _ instability in pumps operating.near their shut off heads. In our August 8,1988 reply to that bulletin we committed to disassembling and inspecting the auxiliary feedwater-1 pumps and to minimize operation at low flow. The inspections indicated that some -degradation had occurred which was not revealed by the high pressure-low flow lestirgc The pumps hr.ve since been overhauled. The new benchmark performance

data for ASME Section XI testing was gathered by pumping at full flow to the steam generators. A new 1011 flow recirculation line was adr%d during the latest Unit 2 refueling outage and le Seing installed during the current Unit 1 outage to permit full-p flow testing at power ', tnout affecting the steam generators or normal feedwater regulation; Ourquarterly Section XI testing is now done at flow conditions near the -

oump's best efficiency pointJ This. test provides early warning of degradation and'is similar to' conditions when the pump is periorming its safety function. If the monthly test could be done under similar conditions, safety would be enhanced because there would be less pump wear and more effective to r ig. The specific values for pressure and flow will no. longer be in the Technical l Specifications. Rather, they can be reevaluated as required by the Code. Removal of the pressure and flow figures is consistent with the NRC's policy on Technical Specification improvements. Because the specific values are not in the Merits ~ Techn; cal Specifications, no~ Merits change is attached. 'f V' a

. -. ~ m' 'f... m-r ' j } f.+ s i

elf,

' r m,_ _ ;-. k 5 . D.

1; ' e

'nt p7 r; ga 1. - -.- f. ;.

$ 3-

?. k. it.? t

y*;h;' ;c[.

V r,. M

n.

4 4~. 4s i '9 .g g.. b.a. A f-A< grng f,4 jh[.' h ','. i.,) f O fa j[ ? 1 4 r nw <- _. y e -. y M.. ;Q!( m .s .os.. j% ;@ l.

(

I** 2) .b j 'i l 4 '( 'P.:,.f. @W.n@k - 'i u J n m,, a .~ a m1

V
\\

)i : shs\\W L s { GY I ) I., 1

H. v. 1

< '.'i: u FC a i cy : ', )l

?

wm, < ;1t..ic. ,,, i., c -, 7<; .,,i

1. t i- -'

1 q,' ve. m.f 4.,, , y > M" U 6 3 g'r,'y 3310 HCFR,50.92 Eval'u' at' ion : .4 .y.: n ,cs,+ n = u. li! E > North Anna UnitsL1:and 2 4 m e s o hk ,J<,.Yj ;.. A i

g.,

>.r g, '. 1 v nf. .b 3 t il-y 7 g t A ,t -o , m 4 r i. .. t II I f .') i; Virginia Electric 'and Power -Company-a i If' h 9 n l; 1 5 g n v yn.4-. . w u-e g-sre-.--

.- t I

Basis for No Significant Hazards Determination Virginia Electric and Power Company proposes to revise the acceptance criteria for the monthly testing of auxiliary feedwater pumps required by Technical Specification 4.7.1.2.a. This specification requires a flow test to ensure that the pumps develop a specified discharge pressure and flow. The pumps are also tested quarterly as required by Section XI of the ASME code. The pumps are equipped with minimum flow recirculation lines which :clude orifices just large enough to ensure that the pumps will not overheat when run with all other flow paths closed. This minimum flow was the basis for the original specification. Because the resulting discharge pressure is near the pump's shut off head, the pump is degraded by this operation. This test is also relatively insensitive to degradation. The quarterly test is done at flow conditions near the pump's best efficiency point. The acceptance criteria is based on performance measured after the pumps were overhauled. This test does not hurt the pump,it provides early warning of degradation and is similar to conditions when the pump is performing its safety function. If the mor'thly test could be done under similar conditions, safety would be enhanced because there would be less pump wear and more effective testing. The proposed change deletes the specific pressure and flow requirements for the monthly test and requires that the acceptance criteria be consistent with the monthly test. The_ specific criteria need not be in the Technical Specifications because the ASME code. requires revising the criteria whenever the pump is overhauled. Deleting these parameters is also consistent with the Commission's policy on Technical Specification improvement. The proposed change does not involve an increase in the probability or consequence of an accicient previously evaluated. The auxiliary feedwater system provides water to the steam generators when normal feedwater is unavailable. The consequence of a pump failure will not be changed by this proposed change. The probability of failure will be reduced because there will be less pump wear and testing will be more effective. The proposed change will not create the possibility of a new or different kind of accident. This is not an actual hardware change and does not alter any conditions or assumptions used in accident analysis or Technical Specification basis. The proposed change does not involve a reduction in a margin of safety. The change will not affect the quantity or pressure of auxiliary feedwater provided. Therefore, based on the above considerations, it has been determined that this change does not involve a significant hazards consideration as defined by 10 CFR l 50.92.

}}