- ML17223B234 + (19:10:24, 8 January 2025)
- L-91-203, Special Rept:On 910626,failure of 2B Emergency Diesel Generator Occurred During post-maint Testing Following Implementation of Plant Mod.Caused by Failed Relay.Relay R1X1 Replaced + (19:10:25, 8 January 2025)
- L-91-207, Forwards Response to Suppl 2 to NRC Bulletin 89-001, Failure of Westinghouse Steam Generator Tube Mechanical Plugs + (19:10:26, 8 January 2025)
- ML17223B231 + (19:10:28, 8 January 2025)
- L-91-213, Advises That Payment of Civil Penalty in Amount of $37,500 Electronically Transmitted to NRC on 910723,in Response to Notice of Violation Forwarded Via NRC + (19:10:29, 8 January 2025)
- L-91-198, Forwards Description & Summary of Safety Evaluation of Plant Changes/Mods Made,Reportable Per 10CFR50.59.Rept Includes Plant Changes/Mods Completed Between 900123-910122 + (19:10:31, 8 January 2025)
- ML17223B228 + (19:10:32, 8 January 2025)
- L-91-191, Forwards Corrected Table 3.9 for Semi-Annual Rept - Jan- June 1990 + (19:10:33, 8 January 2025)
- L-91-195, Monthly Operating Repts for June 1991 for St Lucie Units 1 & 2 + (19:10:34, 8 January 2025)
- ML17223B224 + (19:10:36, 8 January 2025)
- ML17223B223 + (19:10:37, 8 January 2025)
- IR 05000335/1991010 + (19:10:43, 8 January 2025)
- ML17223B220 + (19:10:44, 8 January 2025)
- L-91-182, Forwards Results of Plant Beach Dune Survey Conducted on 910530-0604 + (19:10:45, 8 January 2025)
- ML17223B218 + (19:10:47, 8 January 2025)
- ML17223B217 + (19:10:48, 8 January 2025)
- L-91-179, Forwards Unusual or Important Environ Event to Correct Typo Detected in Paragraph a of Attachment in Util Ltr L-91-158 + (19:10:49, 8 January 2025)
- IR 05000335/1991011 + (19:11:01, 8 January 2025)
- L-91-163, Forwards Closeout Summary Rept for NRC Bulletin 79-02,per NRC Request During Insps 50-335/91-02 & 50-389/91-02 Including Schedule for Completion of Remaining as-built Activities + (19:11:05, 8 January 2025)
- 05000335/LER-1991-004-01, :on 910516,late Fire Watch Patrol of Shield Bldg Discovered.Caused by Personnel Error.Shield Bldg Exhaust Fan Secured to Allow Access to Annulus & Fire Watch Entered Annulus & Performed Patrol + (19:11:20, 8 January 2025)
- L-91-169, Monthly Operating Repts for May 1991 for St Lucie + (19:11:21, 8 January 2025)
- L-91-158, Special Rept:On 910513,determined That Plant Criteria for Fishkill Had Been Met.Cause of Mortality Is Insufficient Food Supply.Fish Removed & Disposed of on Site & Velocity Caps Rebuilt + (19:11:24, 8 January 2025)
- ML17223B210 + (19:11:33, 8 January 2025)
- 05000335/LER-1991-003-01, :on 910506,heater Drain Pump 1A Tripped & 4 Later SG Feedwater Pump 1A Tripped Causing Turbine Runback. Caused by Possible Grounding of Heater hi-hi Level Switch. Circuit Breaker 27 Replaced + (19:11:34, 8 January 2025)
- ML17223B207 + (19:11:35, 8 January 2025)
- IR 05000335/1991300 + (19:11:37, 8 January 2025)
- L-91-172, Forwards Response to Request for Addl Info During 910530 Enforcement Conference Re Results of Interviews Conducted in Area of Operations.Interview Topics Include,Procedural Compliance,Independent Verification & Clearances + (19:11:39, 8 January 2025)
- ML17223B204 + (19:11:39, 8 January 2025)
- L-91-166, Informs of Intent to Use ASME Code Case N-426 + (19:11:41, 8 January 2025)
- ML17223B201 + (19:11:43, 8 January 2025)
- ML17223B199 + (19:11:44, 8 January 2025)
- ML17223B197 + (19:11:45, 8 January 2025)
- 05000389/LER-1991-003, :on 910426,shutdown Cooling HX 2A Discovered Out of Svc While Searching for Dc Ground.On 910417,outlet Valve V-3457 Out of Svc.Caused by Mispositioned Cooling Water Valve.Valve Realigned + (19:11:46, 8 January 2025)
- 05000389/LER-1991-004, :on 910503,two Containment Fan Coolers Inoperable Based on Low Component Cooling Water Flow.Caused by Design Error.Flows Returned to Normal Values & Verified to Be Above Tech Specs Limits + (19:11:48, 8 January 2025)
- ML17223B194 + (19:11:49, 8 January 2025)
- ML17223B192 + (19:11:50, 8 January 2025)
- IR 05000335/1991008 + (19:11:53, 8 January 2025)
- ML17223B189 + (19:11:54, 8 January 2025)
- IR 05000335/1991003 + (19:12:15, 8 January 2025)
- ML17223B186 + (19:12:17, 8 January 2025)
- 05000389/LER-1991-002-01, :on 910415,missed Tech Spec Surveillance Discovered.Caused by Procedural Error.Surveillance Procedure Revised to Require Testing of Equipment Relays for Boric Acid Gravity Feed Valves & Cooling Fans + (19:12:18, 8 January 2025)
- IR 05000335/1991009 + (19:12:24, 8 January 2025)
- ML17223B182 + (19:12:25, 8 January 2025)
- L-91-140, Monthly Operating Repts for Apr 1991 for St Lucie Units 1 & 2 + (19:12:26, 8 January 2025)
- ML17223B180 + (19:12:28, 8 January 2025)
- TAC:62278 + (19:12:29, 8 January 2025)
- ML17223B178 + (19:12:29, 8 January 2025)
- ML17223B177 + (19:12:30, 8 January 2025)
- L-91-131, Quarterly Turtle Activities Rept for First Quarter 1991 + (19:12:31, 8 January 2025)
- ML17223B175 + (19:12:32, 8 January 2025)
- L-91-123, Forwards St.Lucie Unit 2 Annual Environ Operating Rept,Vols 1 & 2 for 1990 + (19:12:34, 8 January 2025)