L-91-169, Monthly Operating Repts for May 1991 for St Lucie
| ML17223B212 | |
| Person / Time | |
|---|---|
| Site: | Saint Lucie |
| Issue date: | 05/31/1991 |
| From: | Breen J, Sager D FLORIDA POWER & LIGHT CO. |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| References | |
| L-91-169, NUDOCS 9106210130 | |
| Download: ML17223B212 (16) | |
Text
~ ACCELERATED DIS
- ~
UTION DEMONSTPA.TION SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
ACCESSION NBR: 9106210130 DOC. DATE: 91/05/31 NOTARIZED: NO FACIL:50-335 St. Lucie Plant, Unit 1, Florida Power 6 Light Co.
50-389 St. Lucie Plant, Unit 2, Florida Power 6 Light Co.
AUTH.NAME AUTHOR AFFILIATION BREEN,J.J.
Florida Power 6 Light Co.
SAGER,D.A.
Florida Power S Light Co.
RECIP.NAME RECIPIENT AFFILIATION DOCKET 05000335 05000389
SUBJECT:
Monthly 'operating repts for May 1991 for St Lucie.N/910613 ltr.
DISTRIBUTION CODE:
IE24D COPIES RECEIVED:LTR g ENCL Q SIZE: lO TITLE: Monthly Operating Report (per Tech Specs)
NOTES RECIPIENT ID CODE/NAME PD2'-2 LA NORRIS,J INTERNAL: ACRS AEOD/DSP/TPAB NRR/DOEA/OEAB RGN2 EXTERNAL:
EGS(G BRYCE,J.H NSIC COPIES LTTR ENCL 3
3 1
1 10 10 1
1 1
1 1
1 1
1 1
1 RECIPIENT ID CODE/NAME PD2-2 PD AEOD/DOA
+~&. <<+/ PEB10 REG FILE 01 NRC PDR COPIES LTTR ENCL 1
1 1
1 1
1 1
1 1
1 NOTE TO ALL"RIDS" RECIPIENTS:
PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 20079) TO ELIMINATEYOUR NAlvKFROM DISHUBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!
TOTAL NUMBER OF COPIES REQUIRED:
LTTR 24 ENCL 24
l 1
~
p v
"t
~
P.O. Box 12, Ft. Pierce, FL 34954-0128 JUN 1 3 t99t L-91-169 10 CFR 50.36 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Gentlemen:
Re:
St. Lucie Units 1 and 2
Docket Nos.
50-335 and 50-389 Monthl 0 eratin Re ort Attached are the May 1991 Operating Status and Summary of Operating Experience Reports for St. Lucie Units 1 and 2.
Very truly yours, D. A.
ager Vice esident St.
L ie Plant DAS:JJB:kw cc:
Stewart D. Ebneter, Regional Administrator, Region II, USNRC Senior Resident Inspector, USNRC, St. Lucie Plant Attachments DAS/PSL 4451 9106210130 910531 PDR ADOCK 05000335 R
PDR p~+ Q ~~ ~ Q an FPL Group company pk
P l
~
~
t
~ 4
~
AVERAGE DAILY UNIT PO'HER LEVEL DOCKET NO ~
50-335 DATE COMPLETED BY Z.Z. Breen TELEPHONE 407 465-3550 DAY MONTH MAY AVERAGE DAILY 1991 POSER LEVEL (MWe-Net) 5/ 2/91 5/ 3/91 5/ 4/91 5/ 5/91 5/ 6/91 5/ 7/91 5/ 8/91 5/ 9/91 5/10/91 5/1 1/91 5/12/91 5/13/91 5/14/91 5/15/91 5/16/91 5/17/91 5/1$ /91 5/19/91 5/20/91 5/21/91 5/22/91 5/23/91 5/24/91 5/25/91 5/26/91'/27/91 5/28/91 5/29/91 5/30/91 5/31/91 856 854 849 842 40 142 575 700 846
- 846, 844 848 721 849 845 807 737 851 858 841 588
~
~
~ ~
~
~
~
OPERATING STATUS OPERATING DATA REPORT DOCKET NO 50 335 DATE JUN 1
S 't991 COMPLETFD BY Je iJi BREEN TELEPHONE 407/465/3550 1.
lJNXT NAME)
ST+
LUCXE UNIT 1
2.
REPORTING PERIOD:
MAY 1991 3i LICENSED THERMAL POWER (MWT)i
~780 4i NAMEPI ATE RATING (GROSS MWE)f 8
e 5+
DESIGN ELECTRXCAL RATING (NET MWE)+
838 6i MAXIMUM DEPENDABLE CAPACXTY (GROSS MWE>t 872 7i MAXIMtJM DEPENDABLE CAPACITY (NET MWE) l 839 8
XF CHANGES OCCUR XN CAPACXTY RATINGS <ITEMS NUMBER 3 THROUGH 7)
SINCE LAST REPORT
~
GIVE REASONS:
POWER LEVEL TO WHXCH RESTRICTED~
XF ANY (NET MWE) 10.
REASONS FOR RESTRICTIONS~
XF ANY'ONTHLY
-YTD-CUMULATIVE lii HOURS XN REPORT PERXOD:
12'UMBER OF HOURS REACTOR WAS CRITICAL 13.
REACTOR RESERVE SHUTDOWN HOURS 14.
HOURS GENERATOR ON-LXNE 15'NXT RESERVE SHUTDOWN HOURS 16+
GROSS THERMAL ENERGY GENERATED
<MWH) 17'ROSS ELECTRICAL ENERGY GENERATED (MWH>
18.
NET ELECTRICAL ENERGY GENERATED
<MWH) 19 UNIT SERVXCE FACTOR 28.
UNIT AVAXLABXLXTYFACTOR 21.
CAPACITY FACTOR (USING MDC NET) 22'APACXTY FACTOR (USING DER NET) 23'NIT FORCED OUTAGE RATE 24.
SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS 18/18/91
~
REFUELING 63 DAYS 744 715eie 709+8 Oie 1825086 600690 567661 95' 95i4 9e
'91i9 ii9 3623 3576+4 OiO 3566' OiO 9450032 3154818 2991924 98 '
98i4 98 i 4 99' 0+4 126599iO 96534i9 205+3 95670i9 39i3 246692086 81363450 76884666 75.6 75.6 7I 74i2 4 i 2 25 XF SHUT DOWN AT END OF REPORT PERXOD ESTIMATED DATE OF STARTUP:
UNIT S&JTDOWNS AND POWER REDUCTIONS DOCKET NO.
UNITNAME DATE COMPLETED BY TELEPHONE 0- 35 ST L IE NIT 1 gUN i 3 199>
J. J. BREEN 40 465-35 0 REPORT MONTH MAY 1
1 No.
Date Type Duration (Hours)
Reason'ethod of Shutting Down Reactor'icensee Event Report
¹ System Code'omponent Code'ause
&Corrective Action to Prevent Recurrence 910505 910505 0.0 20.7 N/A N/A RB CONROD RB CONROD Downpowered for Control Rod Testing.
Unit 1 down for Control Rod Testing.
910506 0.0 N/A RC ZZZZZZ Unit 1 held at approximately 45% power for Nuclear Instrumentation Calibration.
910506 910506 F
13.5 0.0 91-03 N/A HH PUMPXX HH PUMPXX Unit 1 was manually tripped due to Feedwater Pump tripping.
Power held at approximately 709o to monitor the 1A Heater Drain Pump and ASI stabilization.
F Forced S
Scheduled Reasea A - Equipmeat failure (cxphsin)
B - Maintcaaacc or Test C - Refueling D - Regulatory astriction E - Operator Traiuag gt Liccase Exaaiinatioa F - Administrative G - Operatioasl Error (Expalin)
H - Other (Explain)
Method 1 - Maaual 2 - Manual Scram 3 - Automatic Scram 4 - Continued 5 - Load Red uctioa 9 - Other (Explam) cubit G - Insttuctions for Pcpatatioa ofData Entry Sheets Licensee Eveat Report (LER) File (NUREG-0161)
Extubit 1 - Same Source
UNIT SHUTDOWNS AND POWER REDUCTIONS DDQEBT NQ.
~5U 3 UNU NANB
~SLU 53 DATE JUN f 3 199l COMPLETED BY J. J. BREEN TELEPHONE
~40 465-3 5 ~
REPORT MONTH MAY 1
1 No.
Date Type Duration (Hours)
Reason'ethod of Shutting
= Down Reactor'icensee Event Report System Code'omponent Code'ause
& Corrective Action to Prevent Recurrence 10 910508 910530 0.0 0.0 B
N/A N/A HH HF PUMPXX XXXXXX Power held at approximately 80Fo to monitor the IA Heater Drain Pump and ASI stabilization.
Unit I downpowered for cleaning of the 1A2 & IB2 waterboxes.
910531 0.0 N/A HF XXXXXX Unit 1 downpowered to approximately 709o for continued waterbox cleaning.
F Forced S Schedukd Rcasoa A - Equipmcat failure (explain)
B - Maintenance or Test C - Rcfueliag D - Reguhtory xatrictioa E - Operator Training gc License Examination F - Administtative G - Opcratioaal Error (Expalia)
H - Other (Exphin)
Method 1 - Manual 2 - Manual Scram 3 - Automatic Scram 4 - Coatinued 5 - Load Reduction 9 - Other (Exphin)
Ed'>it G - nnsttuctioas for Preparation of Data Entry Sheets Liccascc Exeat Report (LER) File (NUREG-0161)
~bit 1 - Same Source
A>
SUMMARY
OF OPERATING EXPERIENCE DOCKET NO ~
50-335 UNIT St. Lucie 1
DATE UH 1 8 199'OMPLETED BX Z.Z. Breen TELEPHONE 407 465-3550 REPORT MONTH MAY 1991 On May 5, 1991, Unit 1 began a controlled shutdown for control rod testing.
Power was then held at 33%
for Transmission and Distribution(T&D) troubleshooting of voltage readings; the Unit then continued to decrease in power for control rod testing until it was taken offline. Control rod testing was completed on May 6,
- 1991, and Unit 1 began to increase in power.
At approximately 454 power a hold was placed upon the Unit for a Nuclear Instrumentation Calibration. At 98% of full power the reactor was manually tripped in response to a runback initiated by the 1A Main Feedwater Pump.
The Unit was returned to power following corrective actions to the 5A feedwater heater level switch and the main feedwater pump low pressure trip setpoint.
The Unit had hold points at approximately 704 and 80%
to monitor the 1A Heater Drain Pump and ASI stabilization.
On May 9,
- 1991, Unit 1 reached 1004 power and remained there until May 30, 1991.
On May 30,
- 1991, Unit 1 reduced power to approximately 70% for cleaning of the lA2
& 1B2 waterboxes.
Due to a need for electrical power Unit 1 was increased to approximately 904 power, and then lowered again to 70% for completion of waterbox cleaning.
In accordance with the requirements of Technical Specification 6.9.1.6, there were no challenges to the PORVs or safety valves during the report period.
AVERAGE DAILY UNIT POWER LEVEL DOCKET NO ~
50-389 I~
DATE COMPLETED BY J.
reen TELEPHONE 407 465-3550 MONTH MAY 1991 DAY AVERAGE DAILY POWER LEVEL (MWe-Net) 5/ 1/91 5/ 2/91 5/ 3/91 5/ 4/91 5/ 5/91 5/ 6/91 5/ 7/91 5/ 8/91 5/ 9/91 5/10/91 5/11/91 5/12/91 5/13/91 5/14/91 5/15/91 5/16/91 5/17/91 5/18/91 5/19/91 5/28/91 5/21/91 5/22/91 5/23/91 5/24/91 5/25/91 5/26/91 5/27/91 5/28/91 5/29/91 5/38/91 5/31/91 806 861
- 857, 868 862 859 86O 838 787 859 859 859 858 860 859 857 852 851 854 821 616 653 701 718 709 829 864 864 862 859 860
p QPERATTNG STATUS OPERATING DATA REPORT DOCVET NO 50 389 DATE ggn 1 8 $ 9t COMPLETED BY Ji iJ+
BREEN TEI EPHONE 407/465/3550 1.
UNXT NAMEl ST.
LUCIF lJNIT 2 2.
REPORTXNG PERIOD f MAY 1991 3i LXCENSED THERMAL POHER (MHT):
2700 NAMEPLATE RATING (GROSS MHE) l 850 5i DESXGN ELECTRICAL RATING (NET MHE):
838 6i MAXIMUM DEPENDABLE CAPACXTY (GROSS MNE) l 882 7r MAXIMUM DEPENDABLE CAPACITY (NET MHE) l 839 Bi IF CH*NGES OCCUR IN CAP*CITY RATXNGS (XTEMS NUMBER 3 THROUGH 7)
SXNCE LAST REPORT r GIVE REASONS l POWER LEVEL To HHICH RESTRICTED ~
XF ANY (NET MME) 10'EASONS FOR RESTRICTIQNSr XF ANY'ONTHLY
-YTD-CUMULATIVE 11.
HOURS XN REPORT PERIOD l 12'UMBER QF HOURS REACTOR HAS CRITXCAL 13.
RE*CTQR RESERVE SHUTDOHN HOURS 14, HOURS GENERATOR ON-l INE 15'NIT RESERVE SHUTDOWN'HOURS 16.
GROSS THERMAL ENERGY GENERATED (MHH) 17'ROSS ELECTRICAL ENERGY GENERATED (MHH)
, 18'ET ELECTRXCAL ENERGY GENERATED (MWH) 19.
UNIT SERVICE FACTOR
'> ~
28.
UNXT AVAILABXLXTYFACTOR 21.
CAPACITY FACTOR (USING MDC NET) 22, CAPACITY FACTOR (USING DER NET) 23m UNIT FORCED OUTAGE RATE 24'HUTDOWNS SCHEDULED OVER NEXT 6 MONTHS 744 744.0 Oi0 744ie Or0 1935709 646280 612337 100i0 100.0 98+1 99+2 OiO 3623 3623+0 Oi0 3623i0 0 '
9699100 3273880 3108685 100 i 0 100+0 102i3 103' OiO 68496.0 58483+3 Or0 57467.3 0 i 0 150488181 50170800 47442788 83.9 83+9 84.1 84.2 5i6 25, XF SHUT DOWN AT END QF REPORT PERXODr ESTIM*TED DATE OF STARTUP:
J v
UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO.
UNITNAME DATE COMPLETED BY TELEPHONE 50-38 ST L CIEUNIT2 JUN Z3 <99' J. BREEN 40 465-3550 REPORT MONTH MAY 1991 No.
Date Type Duration (Hours)
Reason'ethod of Shutting Down Reactor'icensee Event Report
¹ System Code'omponent Code'ause
&Corrective Action to Prevent Recurrence 910520 0.0 B
N/A HF XXXXXX Unit 2 downpowered for waterbox cleaning.
~
I Reason A - Etptipmcnt failure (explain)
B - Maintenance or Test C - Refueling D - Restdatory rcricion E - Operator Training 4t'. License Emnination F - Admmistrative G - Operational Error (Expalin)
H - Other (Explam)
Method 1 - Manual 2 - Manual Scram 3 - Autcinatic Scnun 4 - Continued 5 - Load Reduction 9 - Other (Exphun)
~bit G - Instructions for Preparation ofData Enny Sheets Licensee Event Report (LER) File (NUREG-0161)
Exhil)it 1 - Same Source s
I
~
~
~
SUMMARY
OF OPERATING EXPERIENCE DOCKET NO 50-389~R COMPLETED BY J.J.
Breen TELEPHONE 407 465-3550 REPORT MONTH MAY 1991 On May 20, 1991, until May 25,
- 1991, Unit 2 reduced power for waterbox cleaning.
On May 27, 1991, Unit 2 was at 100% power and remained there for the rest of the month.
In accordance with the requirements of Technical Specification 6.9.1.6, there were no challenges to the PORVs or safety valves during the report period.
~
~
)
~ l 4
~