Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML17326A522 + (20:17:09, 7 January 2025)
- ML17326A520 + (20:17:10, 7 January 2025)
- ML17326A518 + (20:17:11, 7 January 2025)
- ML17326A517 + (20:17:12, 7 January 2025)
- ML17326A515 + (20:17:16, 7 January 2025)
- ML17326A514 + (20:17:17, 7 January 2025)
- IR 05000315/1979028 + (20:17:18, 7 January 2025)
- ML17326A510 + (20:17:20, 7 January 2025)
- ML17326A507 + (20:17:22, 7 January 2025)
- ML17326A503 + (20:17:22, 7 January 2025)
- ML17326A502 + (20:17:23, 7 January 2025)
- ML17326A501 + (20:17:24, 7 January 2025)
- ML17326A499 + (20:17:25, 7 January 2025)
- 05000316/LER-1980-002-03, /03L-0:on 800115,during Integrity Testing of South Safety Injection Train,Excessive Leakage from Safety Injection Valve to Pressurizer Relief Tank Observed.Caused by Undersized Disc Insert.Disc Insert & Nozzle Replaced + (20:17:28, 7 January 2025)
- IR 05000324/2017008 + (20:17:36, 7 January 2025)
- 05000316/LER-1980-001-03, /03L-0:on 800119,during Normal Startup & W/Power Level at Approx 10%,steam Generators Fed Too Much Feedwater Flow Resulting in Drop in Temp Average to 539 F.Cause Not Stated + (20:17:41, 7 January 2025)
- ML17326A487 + (20:17:43, 7 January 2025)
- ML17326A486 + (20:17:44, 7 January 2025)
- ML17326A471 + (20:17:53, 7 January 2025)
- ML17326A470 + (20:17:54, 7 January 2025)
- ML17326A469 + (20:17:55, 7 January 2025)
- 05000316/LER-1979-053-03, /03L-0:on 791226,while Performing Type B & C Leak Tests Several Valves Exhibited Leakage Exceeding Tech Spec Limit.Caused by Sand Deposits on Valve Seating Surfaces & Pitted Valve Seats on Check Valves + (20:17:57, 7 January 2025)
- 05000316/LER-1979-053, Forwards LER 79-053/03L-0 + (20:18:00, 7 January 2025)
- 05000315/LER-1979-065-01, /01T-0:on 791224,during in-house Evaluation of Containment Air Recirculation/Hydrogen Skimmer Sys, Discrepancies Noted Between Math Models & Design Drawings. Cause Not Stated.Mods Made to Supports + (20:18:03, 7 January 2025)
- 05000315/LER-1979-067-03, /03L-0:on 791221,after Update of Axial Power Distribution Monitoring Sys Fz Setpoints,Two of Four Thimbles Used Found Lacking Lowest Sigma.Caused by Personnel Error in Readout.Fz Recalculated Using Correct Thimbles + (20:18:07, 7 January 2025)
- 05000315/LER-1979-066-03, /03L-0:on 791218,glycol Containment Isolation Valve VCR-10 Did Not Close When Control Switch Turned to Closed Position.Cause Not Known.Valve Operated Properly When Manually Shut + (20:18:12, 7 January 2025)
- ML17326A462 + (20:18:13, 7 January 2025)
- ML17326A461 + (20:18:14, 7 January 2025)
- ML17326A456 + (20:18:16, 7 January 2025)
- ML17326A455 + (20:18:17, 7 January 2025)
- ML17326A452 + (20:18:18, 7 January 2025)
- ML17326A449 + (20:18:19, 7 January 2025)
- ML17326A447 + (20:18:20, 7 January 2025)
- 05000316/LER-1979-049-01, /01T-0:on 791218,during Insp of Seismic Class 1 safety-related Piping Sys Per IE Bulletin 79-14,noted Discrepancy in Auxiliary Pipe.Caused by Pipe 3-ft Longer than Specified in Model.Two Addl Restraints Installed + (20:18:24, 7 January 2025)
- 05000316/LER-1979-049, Forwards LER 79-049/01T-0 + (20:18:27, 7 January 2025)
- ML17326A436 + (20:18:28, 7 January 2025)
- ML17326A434 + (20:18:29, 7 January 2025)
- 05000315/LER-1979-063-03, /03L-0:on 791127,in Mode 1,both Boric Acid Transfer Pumps Were Made Inoperable.Caused Intentionally to Unplug Branch Line That Had Solidified + (20:18:37, 7 January 2025)
- 05000316/LER-1979-048-03, /03L-0:on 791201,while in Mode 6,w/refueling Complete,Containment Air Particulate & Air Gaseous Sample Pump Tripped W/Containment Purge in Progress.Caused by Closed Sample Pump Bypass Valve.Valve Adjusted + (20:18:41, 7 January 2025)
- 05000316/LER-1979-043-03, /03X-1:on 791102,during Surveillance Insp,Ice Condenser Divider Barrier Seal Found to Have Cracks in Rubber.Caused by Excessive Compression During Installation. Seal Ring Replaced in Manner Limiting Compression + (20:18:43, 7 January 2025)
- ML17326A429 + (20:18:45, 7 January 2025)
- ML17326A426 + (20:18:45, 7 January 2025)
- 05000316/LER-1979-047-03, /03L-0:on 791124,during Grid Degraded Voltage Relay Calibr,Relay 27-1-201-AB Dropped Out at Nonconservative Value.Caused by Zener Diode Failure.Diode Replaced & Relay Recalibr + (20:18:47, 7 January 2025)
- 05000316/LER-1979-046-03, /03L-0:on 791119,during Refueling,Source Range Neutron Flux Monitor N-31 Failed.Caused by Excessive Moisture in Detector Wells.Detectors Replaced & Dried + (20:18:49, 7 January 2025)
- ML17326A422 + (20:18:51, 7 January 2025)
- ML17326A421 + (20:18:52, 7 January 2025)
- ML17326A415 + (20:18:54, 7 January 2025)
- ML17326A412 + (20:18:56, 7 January 2025)
- ML17326A411 + (20:18:57, 7 January 2025)
- ML17326A410 + (20:18:58, 7 January 2025)
- 05000316/LER-1979-045-03, /03L-0:on 791113,penetration Provided Access from Containment to Auxiliary Bldg Atmosphere Contrary to Tech Specs.Caused by Repair of Bonnet Removed from Hand Valve.Valve Work Suspended + (20:19:00, 7 January 2025)