Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- TAC:45988 + (17:04:33, 7 January 2025)
- ML17342A708 + (17:04:37, 7 January 2025)
- ML17342A702 + (17:04:39, 7 January 2025)
- ML17342A701 + (17:04:40, 7 January 2025)
- ML17342A699 + (17:04:41, 7 January 2025)
- L-86-264, Submits Update on Spds,Per 840214 Commitment to Implement Sys by End of Current Refueling Outage.Spds Hardware Installed & Software Runs on Safety Assessment Sys (SAS) Central Computer.Sas Implementation Program Schedule Encl + (17:04:42, 7 January 2025)
- IR 05000250/1986034 + (17:04:45, 7 January 2025)
- L-86-344, Responds to Violations Noted in Insp Repts 50-250/86-18 & 50-251/86-18.Corrective Actions:Maint Procedure Writers Instructed to Review Plant Changes/Mods to Identify Any Required Changes Per Performance Enhancement Program + (17:04:47, 7 January 2025)
- ML17342A694 + (17:04:47, 7 January 2025)
- ML17342A690 + (17:04:51, 7 January 2025)
- TAC:59178 + (17:04:52, 7 January 2025)
- L-86-341, Forwards Schedule for Completion of Open Human Engineering Discrepancies Listed in Section 3 & App 6B of 860401 Dcrdr Supplemental Summary rept.Long-term Plant Change & Mod Program for Control Room Will Begin by 871231 + (17:04:53, 7 January 2025)
- L-86-338, Responds to Noncompliances Noted in Insp Repts 50-250/86-24 & 50-251/86-24.Corrective Actions:Personnel Counseled to Ensure Training Process Implemented as Designed & Clearance Tags Placed on 480-volt Tie Breakers + (17:04:55, 7 January 2025)
- L-86-358, Forwards Swri Reactor Vessel Matl Surveillance Program for Turkey Point Unit 3:Analysis of Capsule V, Providing Fracture Toughness Test Results for Capsule V Withdrawn on 850316 + (17:04:57, 7 January 2025)
- L-86-340, Informs That WCAP-11145 Will Be Ref to Satisfy NUREG-0737, TMI Action Item II.K.3.31 in plant-specific small-break LOCA Analysis + (17:04:59, 7 January 2025)
- L-86-332, Application for Amends to Licenses DPR-31 & DPR-41,modifying Tech Spec Limiting Condition for Operation for Control Room Ventilation Sys to Allow Implementation of Mods to Satisfy NUREG-0737,Item III.D.3.4.Fee Paid + (17:05:04, 7 January 2025)
- ML17342A678 + (17:05:04, 7 January 2025)
- L-86-348, Confirms Recent Discussions Re Limiting Condition for Operation (LCO) of Emergency Diesel Generators.Interim Administrative Controls Implementing 7-day LCO in Modes 1,2, 3 & 4 Established as Suppl to Tech Spec 3.7.2.b + (17:05:06, 7 January 2025)
- ML17342A673 + (17:05:08, 7 January 2025)
- ML17342A671 + (17:05:09, 7 January 2025)
- L-86-334, RO 86-05:on 860817,during Repair of Control Rod in Position J-5,technician Caught Foot in IAEA Seal String.String Broke. Four Remaining Seals Intact.Seal & String Will Be Turned Over to IAEA During Insp on 860821 & 22 + (17:05:10, 7 January 2025)
- L-86-320, Discusses Rev to Inservice Test Program for Pumps & Valves. Flow Measure Device Will Be Installed on Spent Fuel Pit Cooling Sys Prior to Offload & Storage of Discharged Fuel + (17:05:12, 7 January 2025)
- L-86-346, RO 86-06:on 860821,IAEA Safeguards Inspectors View of Reactor Head Revealed Second Missing Seal in Addition to Missing Seal Reported in RO 86-05.Remaining Seals Provided Indication That Reactor Head Not Removed Since Installation + (17:05:13, 7 January 2025)
- ML17342A664 + (17:05:16, 7 January 2025)
- ML17342A659 + (17:05:17, 7 January 2025)
- ML17342A662 + (17:05:17, 7 January 2025)
- L-86-329, Requests NRC Order Re Emergency Response Capability Re ex-core Neutron Monitors,Per Suppl 1 to NUREG-0737 & Reg Guide 1.97,be Modified to Allow Power Operation Sections of Startup Procedures to Be Completed After Startup + (17:05:19, 7 January 2025)
- ML17342A657 + (17:05:19, 7 January 2025)
- L-86-331, Remits Fee for 860806 Request for Relief from Inservice Insp Program Exam Requirements for First & Second Intervals + (17:05:21, 7 January 2025)
- L-86-254, IAEA RO 86-4:on 860806,IAEA Surveillance Interrupted During Loss of Lighting in Spent Fuel Pool.Caused by Deenergized C-bus,lights & Bridge Crane During Test to Verify Emergency Diesel Generator Loading Evaluation + (17:05:22, 7 January 2025)
- ML17342A647 + (17:05:25, 7 January 2025)
- ML17342A643 + (17:05:26, 7 January 2025)
- ML17342A640 + (17:05:27, 7 January 2025)
- ML17342A638 + (17:05:28, 7 January 2025)
- L-86-309, Responds to Violations Noted in Insp Repts 50-250/86-25 & 50-251/86-25.Corrective Actions:Procedure OP 1004.2 Completed Prior to Unit 3 Restart & Procedure OP 4304.1 Revised.Response to Finding D.2 Will Be Provided by 860806 + (17:05:29, 7 January 2025)
- ML17342A636 + (17:05:31, 7 January 2025)
- ML17342A634 + (17:05:32, 7 January 2025)
- L-86-294, Responds to NRC 860430 Request for Addl Info Re Generic Ltr 83-28,Item 3.1.2, Post-Maint Testing (Reactor Trip Sys Components) & Items 3.2.1 & 3.2.2, Post-Maint Testing (All Other Safety-Related Components) + (17:05:33, 7 January 2025)
- ML17342A631 + (17:05:37, 7 January 2025)
- L-86-304, Forwards Revised Tech Specs Re Adminisrative Control of nonsafety-grade Standby Feedwater Sys,Per NRC Comments. Revs Supersede 860130 Submittal + (17:05:38, 7 January 2025)
- ML17342A627 + (17:05:41, 7 January 2025)
- ML17342A626 + (17:05:42, 7 January 2025)
- ML17342A624 + (17:05:43, 7 January 2025)
- ML17342A622 + (17:05:47, 7 January 2025)
- ML17342A621 + (17:05:48, 7 January 2025)
- ML17342A618 + (17:05:49, 7 January 2025)
- ML17342A619 + (17:05:49, 7 January 2025)
- L-86-303, Forwards Responses to 860616 Request for Addl Info Re Resistor Temp for Pressurized Thermal Shock Projected Values + (17:05:52, 7 January 2025)
- L-86-226, Responds to IE Bulletin 85-003 Re motor-operated Valve Common Mode Failures During Plant Transients Due to Improper Switch Settings.Actual Torque Switch Settings Will Be Calculated & Maintained in Controlled Document + (17:05:54, 7 January 2025)
- L-86-203, Advises That Response to IE Bulletin 85-003 Re motor- Operated Valve Common Mode Failures During Plant Transients Due to Improper Switch Settings Will Be Submitted by 860525 + (17:05:56, 7 January 2025)
- L-86-295, Forwards Response to 860708 Request for Addl Info Re Emergency Diesel Generator Load Evaluation + (17:05:57, 7 January 2025)
- L-86-293, Forwards Updated Listing of Implementation of Generic Items. Addl Info Requested from NRC to Determine Specific Licensing Actions Required for Open Items + (17:05:59, 7 January 2025)