- 05000311/LER-1980-027, Forwards LER 80-027/03L-0 + (10:31:24, 6 January 2025)
- ML18082B173 + (10:31:25, 6 January 2025)
- ML18082B171 + (10:31:26, 6 January 2025)
- ML18082B172 + (10:31:26, 6 January 2025)
- ML18082B169 + (10:31:27, 6 January 2025)
- ML18082B167 + (10:31:28, 6 January 2025)
- ML18082B165 + (10:31:29, 6 January 2025)
- ML18082B163 + (10:31:30, 6 January 2025)
- 05000311/LER-1980-026-03, /03L-0:on 800811,during Review of Records, Determined That Reactor Was Taken Critical W/O Performing Functional Test on Source Range Instruments.Caused by Personnel Error + (10:31:34, 6 January 2025)
- CAC:001094 + (10:31:35, 6 January 2025)
- 05000311/LER-1980-026, Forwards LER 80-026/03L-0 + (10:31:39, 6 January 2025)
- ML18082B153 + (10:31:40, 6 January 2025)
- ML18082B151 + (10:31:41, 6 January 2025)
- ML18082B149 + (10:31:42, 6 January 2025)
- ML18082B148 + (10:31:43, 6 January 2025)
- ML18082B147 + (10:31:44, 6 January 2025)
- 05000272/LER-1980-046-03, /03L-0:on 800810,during Routine Operation,Steam Generator Level Feed flow-steam Flow Mismatch Circuit 12 Failed.Caused by Failure of Comparator in Circuit.Unit Replaced & Tested Satisfactorily + (10:31:47, 6 January 2025)
- 05000272/LER-1980-046, Forwards LER 80-046/03L-0 + (10:31:51, 6 January 2025)
- 05000272/LER-1980-045-03, /03L-0:on 800806,air Particulate Detector Pump Seized.Apparently Caused by Equipment Failure.Pump Replaced + (10:31:55, 6 January 2025)
- 05000272/LER-1980-045, Forwards LER 80-045/03L-0 + (10:31:59, 6 January 2025)
- 05000272/LER-1980-044-03, /03L-0:on 800805,during Routine Containment Entry, Containment Air Lock Became Inoperable.Caused by Broken Roller on Outer Door.Roller Replaced & Tested Satisfactorily + (10:32:01, 6 January 2025)
- 05000272/LER-1980-044, Forwards LER 80-044/03L-0 + (10:32:02, 6 January 2025)
- ML18082B136 + (10:32:07, 6 January 2025)
- ML18082B135 + (10:32:08, 6 January 2025)
- ML18082B134 + (10:32:09, 6 January 2025)
- ML18082B133 + (10:32:10, 6 January 2025)
- PNO-I-80-110, on 800725,IBEW Union Went on Strike.Unit 1 Operations Are Continuing W/Licensed Supervisory Personnel. All Phone Lines at Facility Have Been Disabled + (10:32:13, 6 January 2025)
- IR 05000454/2018411 + (10:32:14, 6 January 2025)
- ML18082B129 + (10:32:14, 6 January 2025)
- ML18082B118 + (10:32:16, 6 January 2025)
- ML18082B116 + (10:32:17, 6 January 2025)
- ML18082B115 + (10:32:18, 6 January 2025)
- TAC:8670 + (10:32:19, 6 January 2025)
- ML18082B113 + (10:32:20, 6 January 2025)
- 05000272/LER-1980-043-03, /03L-0:on 800801,during Routine Surveillance of Control Console,Water Level in Refueling Water Storage Tank Determined to Be Below Min Level (350,000 Gallons).Cause Due to Addition of Water to Spent Fuel Pit.Tank Refilled + (10:32:21, 6 January 2025)
- 05000272/LER-1980-043, Forwards LER 80-043/03L-0 + (10:32:23, 6 January 2025)
- 05000272/LER-1979-057-01, During IE Bulletin 79-14 Insp of Pipe Hangers on Seismic I Sys,Three Hangers Found to Hve Broken Weld,Bolt & Pipe Guide.Caused by Irregular Pulsations of Charging Pump 13,stressing Supports + (10:32:25, 6 January 2025)
- 05000272/LER-1979-057, Forwards Updated LER 79-057/01X-1 + (10:32:26, 6 January 2025)
- 05000272/LER-1979-004, Forwards Updated LER 79-004/03X-1 + (10:32:28, 6 January 2025)
- 05000311/LER-1980-022-03, /03L-0:on 800731,jacket Water Heater Developed Leak Which Caused Jacket Water Heater for 2A Diesel to Trip. Caused by Equipment Failure.Heater Replaced.Design Change Issued for Different Type Heater + (10:32:29, 6 January 2025)
- 05000311/LER-1980-022, Forwards LER 80-022/03L-0 + (10:32:31, 6 January 2025)
- 05000311/LER-1980-023-03, /03L-0:on 800731,chemical Analysis of Refueling Water Storage Tank Revealed Boron Concentration at 1980 Ppm. Caused by Personnel Error.Action Was Taken to Increase Concentration Above Min of 2,000 Ppm + (10:32:33, 6 January 2025)
- 05000311/LER-1980-023, Forwards LER 80-023/03L-0 + (10:32:34, 6 January 2025)
- 05000311/LER-1980-024-03, /03L-0:on 800801,while Withdrawing Rods in Preparation for Entering Mode 2,position Indicator Read 20 Steps Lower than Bank Demand Position.Caused by Equipment Failure.Individual Rod Position Indicator Replaced + (10:32:38, 6 January 2025)
- ML18082B094 + (10:32:40, 6 January 2025)
- ML18082B084 + (10:32:41, 6 January 2025)
- ULNRC-06414, Request to Extend Enforcement Discretion Provided in Enforcement Guidance Memorandum 15-002 for Tornado-Generated Missile Protection Non-Conformances Identified in Response to Regulatory Issue Summary 2015-06, Tornado . + (10:32:42, 6 January 2025)
- ML18082B074 + (10:32:45, 6 January 2025)
- ML18082B076 + (10:32:45, 6 January 2025)
- ML18082B071 + (10:32:46, 6 January 2025)
- ML18082B039 + (10:32:47, 6 January 2025)