- 05000353/LER-1999-004-02, :on 990701,determined That Thirteen MSRVs Failed to Meet 1% Setpoint Tolerance Due to Setpoint Drift.Caused by Corrosion Induced Bonding Between Pilot Disc & Seat.All Fourteen Srvs Pilot Valves Were Replaced + (21:38:20, 6 December 2024)
- ML20210D576 + (21:38:21, 6 December 2024)
- ML20210D581 + (21:38:21, 6 December 2024)
- ML20210D575 + (21:38:22, 6 December 2024)
- ML20210D574 + (21:38:23, 6 December 2024)
- 05000353/LER-1999-004, Forwards LER 99-004-00 Re 990701 Discovery of Pressure Setpoint Drift of Thirteen Mss SRV Due to Corrosion Induced Bonding within SRVs + (21:38:24, 6 December 2024)
- ML20210D567 + (21:38:24, 6 December 2024)
- ML20210D565 + (21:38:25, 6 December 2024)
- ML20210D561 + (21:38:26, 6 December 2024)
- ML20210D559 + (21:38:27, 6 December 2024)
- ML20210D560 + (21:38:27, 6 December 2024)
- ML20210D556 + (21:38:30, 6 December 2024)
- ML20210D551 + (21:38:31, 6 December 2024)
- ML20210D550 + (21:38:31, 6 December 2024)
- ML20210D548 + (21:38:32, 6 December 2024)
- ML20210D547 + (21:38:32, 6 December 2024)
- ML20210D543 + (21:38:33, 6 December 2024)
- ML20210D541 + (21:38:34, 6 December 2024)
- 05000440/LER-1986-051, :on 860818,discovered That RHR Containment Upper Pool Cooling Isolation Valves Did Not Receive Reactor Vessel High Pressure Isolation Signal as Stated in FSAR Table 6.2-32.Surveillance Instruction Revised + (21:38:37, 6 December 2024)
- RBG-36909, Forwards Update to Gsu Previous Response to Final Rule for ERDS & Final Data Point Library,Including Revised Stability Class Data Sheets Indicating Stability Classes 1-7 + (21:38:38, 6 December 2024)
- ML20210D531 + (21:38:39, 6 December 2024)
- ML20210D530 + (21:38:40, 6 December 2024)
- ML20210D528 + (21:38:41, 6 December 2024)
- ML20210D527 + (21:38:43, 6 December 2024)
- ML20210D525 + (21:38:44, 6 December 2024)
- 05000364/LER-1992-005, :on 920512,following Refueling Outage,Reactor Tripped Due to Low Water Level in SG Coincident W/Feedwater Flow than Steam Flow Signal.Caused by Personnel Error. Control Room Staff Reinstructed + (21:38:46, 6 December 2024)
- ML20210D520 + (21:38:47, 6 December 2024)
- 05000440/LER-1986-049, :on 860818 & 19,gaseous Effluent Vent Stack Flow Estimates Not Performed Once Per 4 H as Required by Tech Specs.Caused by Personnel Error.Operators Counseled & Administrative Procedures Revised + (21:38:49, 6 December 2024)
- ML20210D517 + (21:38:51, 6 December 2024)
- ML20210D515 + (21:38:51, 6 December 2024)
- ML20210D514 + (21:38:52, 6 December 2024)
- ML20210D510 + (21:38:54, 6 December 2024)
- ML20210D508 + (21:38:54, 6 December 2024)
- 05000440/LER-1986-048, :on 860819 & 20,unexpected RHR Sys Isolations Occurred During Performance of Maint Retest.Caused by Inadequate Surveillance Test Instruction (Svi) & Poor Jumper Connection,Respectively.Svi Revised + (21:38:57, 6 December 2024)
- ML20210D503 + (21:38:58, 6 December 2024)
- IR 05000298/1986036 + (21:39:08, 6 December 2024)
- ML20210D496 + (21:39:11, 6 December 2024)
- ML20210D494 + (21:39:12, 6 December 2024)
- ML20210D488 + (21:39:13, 6 December 2024)
- ML20210D489 + (21:39:13, 6 December 2024)
- ML20210D487 + (21:39:15, 6 December 2024)
- ML20210D485 + (21:39:15, 6 December 2024)
- ML20210D482 + (21:39:16, 6 December 2024)
- ML20210D481 + (21:39:17, 6 December 2024)
- ML20210D476 + (21:39:19, 6 December 2024)
- LD-86-038, Provides Info for Reactor Coolant Pump Data Bases on C-E Designed NSSS 80 for facilities.WPPSS-3 Should Be Added to Data Base + (21:39:24, 6 December 2024)
- 05000313/LER-1992-004-03, :on 920515,discovered That TS Required Post Maint Test for Containment Isolation Valve Not Performed Prior to Heatup/Startup from Outage on 920504.Caused by Faulty Work Process.Action Team Formed + (21:39:26, 6 December 2024)
- ML20210D465 + (21:39:30, 6 December 2024)
- ML20210D464 + (21:39:31, 6 December 2024)
- NOC-AE-000598, Forwards Four Copies of 1RE08 Refueling Outage ISI Summary Rept for Steam Generator Tubing + (21:39:32, 6 December 2024)
- ML20210D459 + (21:39:33, 6 December 2024)