Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19242A445 + (18:54:21, 4 January 2025)
- ML19242A444 + (18:54:22, 4 January 2025)
- ML19242A443 + (18:54:22, 4 January 2025)
- ML19242A442 + (18:54:37, 4 January 2025)
- ML19242A440 + (18:54:38, 4 January 2025)
- ML19242A439 + (18:54:39, 4 January 2025)
- ML19242A438 + (18:54:40, 4 January 2025)
- ML19242A437 + (18:54:43, 4 January 2025)
- ML19242A436 + (18:54:44, 4 January 2025)
- ML19242A434 + (18:54:45, 4 January 2025)
- ML19242A433 + (18:54:46, 4 January 2025)
- ML19242A432 + (18:54:47, 4 January 2025)
- ML19242A431 + (18:54:48, 4 January 2025)
- ML19242A430 + (18:54:49, 4 January 2025)
- ML19242A428 + (18:54:50, 4 January 2025)
- ML19242A427 + (18:54:51, 4 January 2025)
- ML19242A426 + (18:54:52, 4 January 2025)
- ML19242A424 + (18:54:53, 4 January 2025)
- ML19242A425 + (18:54:53, 4 January 2025)
- ML19242A422 + (18:54:54, 4 January 2025)
- ML19242A419 + (18:54:55, 4 January 2025)
- ML19242A418 + (18:54:56, 4 January 2025)
- ML19242A416 + (18:54:57, 4 January 2025)
- ML19242A417 + (18:54:57, 4 January 2025)
- ML19242A415 + (18:54:58, 4 January 2025)
- ML19242A414 + (18:55:06, 4 January 2025)
- ML19242A412 + (18:55:08, 4 January 2025)
- ML19242A411 + (18:55:08, 4 January 2025)
- ML19242A410 + (18:55:09, 4 January 2025)
- ML19242A409 + (18:55:10, 4 January 2025)
- ML19242A406 + (18:55:12, 4 January 2025)
- ML19242A408 + (18:55:12, 4 January 2025)
- ML19242A405 + (18:55:13, 4 January 2025)
- ML19242A404 + (18:55:13, 4 January 2025)
- ML19242A402 + (18:55:14, 4 January 2025)
- ML19242A401 + (18:55:15, 4 January 2025)
- 05000309/LER-1979-015-03, /03L-0 on 790712:during Operation,Rps Channel a Hi Power Matrix Trip Lights Illuminated But pre-trip & Trip Lights Did Not.Caused by Failed 15 Volt Dc Power Supply.Unit Replaced in Kind & Returned for Analysis + (18:55:35, 4 January 2025)
- 05000309/LER-1979-015, Forwards LER 79-015/03L-0 + (18:55:38, 4 January 2025)
- ML19242A397 + (18:55:45, 4 January 2025)
- ML19242A396 + (18:55:47, 4 January 2025)
- 05000298/LER-1979-016-03, /03L-0 on 790531:RHR Pump 1A Tripped During Start on Overcurrent in Phase C.Caused by Failure of GE Model 121AC66K8A Overcurrent Relay Operating Disc to Return to Normal Position.Relay Cleaned,Recalibr & Retested + (18:55:48, 4 January 2025)
- 05000298/LER-1979-016, Forwards LER 79-016/03L-0 + (18:55:50, 4 January 2025)
- 05000259/LER-1979-011-03, /03L-0 on 790628:scram Discharge Level Switch, LS-85-45B,found Failed in Unsafe Direction.Caused by Buildup of Foreign Matl in Pivot Pin Area Which Prevented Movement of Switch Actuator Rod.Swich Was Cleaned + (18:55:52, 4 January 2025)
- 05000348/LER-1979-028-03, /03L-0 on 790627:radiation Monitor R-5 Declared Inoperable Due to Loss of Power.Feedbreaker Found Open. Cause Unknown.Breaker Closed & R-5 Declared Operable + (18:55:54, 4 January 2025)
- ML19242A390 + (18:55:55, 4 January 2025)
- 05000259/LER-1979-011, Forwards LER 79-011/03L-0 + (18:55:57, 4 January 2025)
- 05000348/LER-1979-026-03, /03L-0 on 790716:total of 135 Hydraulic Snubbers Did Not Meet Surveillance Test Requirements.Caused by Loss of Oil Due to Seal Leakage & Failure to Meet Lockup & Bleed Acceptance Criteria.Snubbers Repaired & Tested + (18:55:58, 4 January 2025)
- 05000277/LER-1979-035-01, /01T-0 on 790706:insp Program,Performed in Response to IE Bulletin 79-02,revealed 18 shell-type Anchors Which Failed to Torque Properly.Caused by Incorrect Installation.Anchors Properly Replaced + (18:56:00, 4 January 2025)