ANNUAL OPERATING REPORT FOR LICENSE R-74 TO THE UNITED STATES NUCLEAR REGULATORY COMMISSION FOR FISCAL YEAR 1978-1979 4 ', 3 287 PREPARED BY:

R. J. CASHWELt.

DEPARTMErlT OF MijCLEAR EtlGitlEERiflG

'9 08010 S9 f, 7

ANNUAL REPORT A.

SUMMARY

_OF OPERATIONS l.

Instructional Use - UW-Madison Formal Classes Three Nuclear Engineering Department classes make use of the reactor.

[

The 45 Students enrolled in NE 231 participated in a two-hour experiment designed to acquaint students with behavior characteristics of a nuclear reactor. Thic experiment was repeated four times.

NE 427 had a total en-t rollment of 29 students as 't was offered in both Fall and Spring semesters.

Several NE 427 experiments use materials that are activated in the reactor while one experiment entitled, " Radiation Survey' requires that students I

make measurements of radiation levels in and arounc ;'ie reactor laboratory.

l NE 428 makes extensive use of the reactor as it is taught during both I

semesters and summer school.

32 students completed NE 428 during the fis-cal year.

NE 428 incorporates three experiments (" Critical Experiment",

" Control Element Calibration", and " Pulsing") which require exclusive use of the reactor. These experiments were repeated f *ve times for NE 428 classes. Two additional 428 experiments (" Fast Neutron Flux Measurements by Threshold Foil Techniques" and " Resonance Absorption") were repeated ten times each during the year. These experiments use the reactor for activation of foils for the measurements.

At least one session in the reactor laboratory was included in the courses of tne Departments of General Engineering, Metallurgical and Mineral Engineering, Physics, Chemist.y. Journalism, and Mechanical En-gineering.

In addition, laboratory personnel presented formal lectures for Introductory Chemistry ar.d Physics classes on the general subject of nuclear power and with specific applications to the Three-Mile Island ac-cident.

I 2.

Reactor Sharing Procram c

^Q3 The work by the University of Minnesota-Duluth group (b 7sta ff[mes bers and 2 graduate students) on identificc. tion of copper ar.d tin arti-facts and nres by multielement Ins;rumental Neutren Activation Analysis 1

continued.

Personnel from the University of Wisconsin-Stevens Point pet-ticipated in the Reactor Sharing Progrcm two ways.

First, during the summer, they brought a group of 25 high scicol students enrolled in a summer program for a reaccor operation demonstration.

In addition, during the serester, a group of s':udents (5 students, I staff member) came to our laboratory and participated in the reacter operation demon-stration previously developed for our flE 2.}! classes.

12 students from the University of Wisconsin-fiilwaukee spent th ee hours in a laboratory session on Instrumental fleutron Activation Analysis as a part of their course number CE 891-3. A group of 8 Advanced Physics students from Lcercil College attended a 3-hour fleutron Activation Analysis laboratory at ou. facility. 8 students from Beloit College attended a reactor opera-tion demonstration.

Finally, '2 students from the University of Wisconsin-Platteville attended a 3-hour fleutron Activation Analysis laboratory session.

3.

Utility Operating Personnel Training Two-week research reactor familiarization courses were held for two groups of 6 trainees from Cleveland Electric Illuminating Company. The 12 people trained will be part of the operating staff of the two-unit BW'i Perry Generating Plant.

The program occurs early in the academic training of individuals who are car.didates for operator and senior operator licens-ing and who do not have considerable previous nuclear training.

Most of the students in the two groups are persons with operating experience in

%nventional power plants.

The progras acquaints the students with reac-tor kinetic behavior, instrumentation, operating practice, and general tech-niques involved in dealing with radioactive materials. The session at Wisconsin is essentially the laboratory portion of a training program con-ducted for Cleveland Electric Illuminating by the General Physics Corpora-tion.

4.

Sample Irradiation and fleutron Activation Analysis Services During the year, 4,803 samples were irradiated.

1217 of these sam-pie irradiations were for 15 c;.iutes or less, while the remainder accumu-lated 9,121.95 samnle hours of irradiation.

The irradiation work can be further classified into 862 irradiations and 447.7 irradiation space hours.

3,637 of the samples irradiated (76f of the total) were irradiated as part of the laboratory's fluetron Activation Analysis Service in which samples are submitted by outside users for subsequent sample preparation and analy-sis by Instrumental fleutron Activation Analysis.

A listing of the individual groups for whom irradiations were per--

formed follaws.

In this listing, information is supplied on the object of the research, personnel involved, and sponsoring organization where known.

c,r. ~i 7

o

. The parenthetical expression (flAA) with an entry indicates the work was performed by the UWNR tieutron Activation Analysis Service.

Agricultural Engineering.

(NAA) 8 samples, all less than 15 minutes.

Professor J. Converse and 1 graduate student. Use of flAA in study to find methods of controlling odor in stored pig manure. Supported by Hatch Act.

Allis Chalmers.

95 samples, all less than 15 minutes. Activation of limestone for use in tests of grinding and mixing equipment.

Beloit (Wisconsin) Sewage Treatment District.

(NAA) 36 samples, 72 sample hours. NAA of sewage sludges for determination of suitability for use on agricultural lands.

Biochemis try.

(NAA) 30 samples,14 less tha'i 15 minutes, 25.6 sample hours.

Professor M. A. Stahmann and 1 graduate student.

Estab-lish levels of metals influencing the fruiting of the mushroom Lentinus Edodes.

Supported by WARF.

Biochemistry.

7 samples, 21 sample hours.

Professors W. Orme-Johnson,

fl. Orme-Johnson, and T. Rademacher, M. D.

Production of copper-64 for tracer use in atloradiography of cells.

Supported by NIH.

Chemical Engineering.

(NAA) 47 samples all less than 15 minute irra-diations.

Professor E. Lightfoot and i graduata student.

Determination of amount of glass suspended in mineral oil by NAA of sodium content.

Supported by NSF.

Chemistry.

(NAA) 35 samples,14 less than 15 minutes,10.5 sample hours.

Graduate student M. Louise Bleam studies the binding of small cations to nucleac acids using sodium.

Supported by NSF.

Civil and Environmental Engineering (Water Chemistry).182 samples, 82 less than 15 minutes, 282 sample hours.

Professor A. Andren, 3 graduate students, and 1 post-doctoral fellow. Use of NAA for qualification of com-position of sediments and particulates.

Supported by EPA, Corps of Engineers, and Sea Grant Program.

Dairy Science Department.

(NAA) 1707 samples, 5223 sample hors.

Professors t.. Satter and N. Jorgensen, 2 graduate students,1 undergraduate student.

Use of stable tracers in feed to determine digestability, runen turnover, and rate of passage in dairy cattle.

Supported by Hatch Act, state funds, and gi f t funds.

Geology and Geophysics.

(NAA) 116 samples, 53 less than 15 minutes.

126 sample hours.

Professor 6. Medaris and 3 graduate students.

Chemical g f> 7

} 'l O analysis of baalt to investigate geological history of the area and for mi.;eral exploration purposes. Supported by Geology Department fund and Industrial Grant.

Globe Union.

(NAA) 148 samples, 269 sample hours. NAA for quality control purposes, primarily investigation of radiomechanism in lead acid storage batteries by multielement analysis of rejected battery components.

Institute of Paper Chemistry (NAA) 3 samples, all less than 15 minutes; other 72 samples, 78 sample hours. flAA of fibers to determine their utilization as tracers and irradiation of fibers to be used in tracer experiments in laboratory scale process investigations.

ficArdle Labs.

6 samples, 3 less than 15 minutes, 6 sample hours.

Professor C. Kasper and I graduate student. NAA of trace quantities of metals in microsomal membrane.

Funded by National Cancer Institute.

Mechanical Engineering.

(NAA) 2 samples, both less than 15 minutes.

Professor Seireg and 1 graduate student.

Determination of amount of tung-sten in tool bit fragment. Supported by Falk Corporation.

tiechanical Engineering. 13 samples, all less than 15 r;inute irradi-ations.

Professor G. Borman and I graduate student.

Production of Argon-41 tracer used to trace fluid motion in a deisel engine combustion chamber.

Supported by 20E and Detroit Deisel-Allison Division of General Motors.

Mechanical Engineering.

(NAA) 208 samples, 205 less than 15 minutes 1.5 sample hours.

Professor K. Ragland, 2 graduate students.

Use of NAA in air pollution emissions control for combustion of coal and refuse.

Sup-ported by DOE.

Medicine.

(NAA) 51 samples, all less than 15 minute irradiations.

Professor R. Barreras and 1 staff member.

Determination of relative dis-solution of aluminum and magnesium hydroxides from mixed gals reacting with acio and gastric juice (studying efficiency of mixed antacids for human use).

Supported by a gift from the Louis Howe Corporation.

Medicine.

(NAA) 6 samples, 2 less than 15 minutes, 5 sample hours.

Professor M. Evenson, 3 additional staff members, 2 graduate students, and 1 post-doctoral fellow.

NAA of trace elements in biological specimens.

Funded by University Hospitals.

Medicine.

8 samples, all less that. 15 minute irradiations.

Pro fes so r S. Updike, 2 additional staff members, and i post-doctoral fellow.

Production of tracers used to measure catalytic effects in membranes used in artificial kidneys.

Supported by National Institutes of Health.

,2 q y3 Metallurgical and Mineral Engineering (Energy Storage Project). (NAA) 65 samples,130 sample hours.

Professor R. Boom, 4 graduate students,1 post-doctoral fellow. Use of NAA to measure concentration of impurities in superconducting alloys. Supported by DOE, NSF.

Nuclear Engineering - NE 427.

110 samples, 84 less than 15 minutes, 26 sample hours.

Irradiations of foils and Neutron Activation Analysis samples for a student laboratory course.

Nuclear Engineering - Reactor Laboratory.

188 samples, 69 less than 15 minutes, 256.3 sample hours.

Irradiation of materials for fleutron Acti-vation Analysis tests, production of materials for instrument calibrations, and irradiations incident to operator training programs.

Radiology-fluclear Medicine Section.

30 samples, J0.56 sample hours.

Professor S. Gatley and 2 graduate students.

Production of fluorine-18 labeled radiopharmaceuticals.

Supported by a Medical School Research Com-mittee.

Radiology-Human Oncology.

(NAA) 61 samples, 32 less than 15 minutes.

14.5 san.oie hours.

Professor A. Wiley and 1 graduate student.

Detection and monitiring of heavy elements in human tumors.

Supported by private patient dcnations, University Radiotherapy Associates R & D Funds, and Nationai Cincer Institute.

Ral t !ch Incorporated.

(flAA) 25 samples,16 less than 15 minutes,18 sample hot rs.

NAA of biological material for contamination checks.

Reat tor Sharing Program.

(NAA) 116 samples, 8 less than 15 minutes, 162 sampi+ hours. Most of these samples were irradiated for the research group at the University of Minnesota-Duluth.

Professor Rapp, 2 additional staff members,1 graduate student, and 1 undergraduate are concerned with this study in which fleutron Activation Analysis is used to investigate the composition of copper and tin containing archaeological samples for deter-mination of origin and technology.

This work is supported by the Departnent of Energy through the Reactor Sharing Program, and the remainder of Profes-sor Rapp's work is sup~

d by a private philanthropist.

Department of Soil Science. 273 samples, 24 less than 15 minutes, 945 sample hours.

Professor P. Helmke, 2 graduate students,1 post-doc-toral fellow, and 1 undergraduate use the reactor as an irradiation device in their Neutron Activation Analysis of soils, rocks and biological samples.

Research is supported by EPA, Wisconsin Power & Light, 00E, and the Coopera-tive State Researcn Service (Hatch).

C. $. $

2

,L

- g University of Wisconsin-Milwaukee.

(NAA) 82 samples, 82 sampi ! hours.

Professor E. Christensen and 1 graduate student.

Use of Neutron Acti ration Analysis for analysis of *ediment samples in studies of environmental pro-i l

tection.

Supported by Advanced Opportunity Program.

U.S. Army Cold Regions Research Laboratory.

(NAA) 543 samplas, 306 less than 15 minute irradiations. 474 sample hours. Samples of soil, par-ticulates, sediments, and foliage were investigated to determine impact on the environment of human activity in a polar area.

i U.S. Department of Aariculture, Be'tsville, Maryland.

(?!AA) 315 samples, 27 less than 15 minutes,144 sample hours.

Dr. Haaland is using stable tra-cers and Neutron Activation Analysis in a study of dairy cattle foodstuff utilization.

Wisconsin Department of Natural Resources - Rhinelander, Nisconsin.

Analysis of municipal w.ste water sludges and soils.

i 5.

Chanr'es in Personnel, Facility, and Procedures Don,'l E. Range, a full-time reactor operator / technician joined the staff during the summer of 1978 and is presently licensed as a reactor oper-ator.

Three part-time employees, Herbert O. Nelson, Michael C. Jensea, and Jeffrey P. Ladewig have been licensed as operators during the year.

No reporta'.

Changes in the facility as described in the Safety Ant.-

lysis Report were made during the year.

The refueling of the core toward a l

full FLIP core was continued.

The last run with a mixed core was completed on 14 June 1979.

Six additional FLIP bundles were received on 13 June 1979 i

and loaded by Critical Experiment into 'he core on 15 June 1979.

The full FLIP core was critical at 1432 on 15 June 1979, on 18 bundles, with an ex-cess reactivity of.08% and a shutdown margin of 7.5%.

The core was loaded to a 21-bundle all-FLIP configuration which was checked for compliance with Technical Specification requirements on shutdown margin and transient rod worth and then operated at power in order to bring the new FLIP fuel to self-protecting levels.

This was necessary to assure that the license requirement limiting quanti +y of non-protected 70% enriched fuel was met. An additional shipment of FLIP to complete the 25-bundle FLIP core i', expected the last week in July, and a full test program will then be completed. A complete description of the reloading and test program on the full FLIP core will be issued subsequent to completion of the test program.

Only minor changes to procedures were made to update procedures for current conditions.

None of the changes are reportable under conditicns of 7

. !; 7 3

b o

the Technical Specifications.

Some changes were made in the 130 series of procedures (dealing with sample irradiation) in order to conform to the changes in campus requirements for transfer of nterial to the University's broad license. The changes require a -lephone check of the current status of the authorization of individuals to whom.eactor-produced radioisotopes are to be transferred.

In addition, the i..dividual picking up a sample will receive a copy of the irradiation request, and another copy of the irradia-tion request with information on Ate and time of the irradiation will be submitted to University Health F. 3 cs as a receipt document.

6.

Results of Surveillance Tests Surveillance tests and inspections during the year revealed no pro-blems in safety-related systems.

Surveillance of licensed operator per-formance under the Operator Proficiency Maintenance Program showed no de-ficiencies on written examinations. One operator was suspended from li-censed duties because of an unsatisfactory evaluation in oral exanination.

He is required to undergo additional training and at least ten reactor startup cycles before Se may be re-evaluated and restos ad to operating status.

B.

OFdRATING STATISTICS AND FUEL EXPOSURE Startups Critical Hours MW H 1

Pulses

~

FY 78-79 155 480.27 13.

55 Total on TRIGA Cores

  • 2065 7111.E7 211.65 1361
  • Summary of exposures since converting to TRIGA fuel Initial Standard TRIGA Core - 1st Critical - 14 November 1967 Total on Standard Core 4807.5 144.96 941 9 Bundle FLIP - 16 Bundle Standard - 1st Critical - 4 March 1974 Accumulated 1575.30 49.54 303 For Total of (6382.80)

(194.52)

(1224) 15 Bundle FLIP

_10 Buncle Standard - 1st Critical - 3 January 1978 Accumulated 696.95 15.99 137 For Total of (7079.75)

(210.51)

(1361)

At last run, excess reactivity had decreased 0.13"> from the initial value for this cc. e of 3.90% AK/K.

21 o"odle ALL FLIP - 1st Critical - 15 June 1979 e cunulated (to 30 June) 32.12 1.15 0

(Totals Above)

E li },

29 C.

EMERGENCY SHUTDOWNS AND INADVERTENT SCR/.MS There were no emergency shutdowns during the year.

There were, how-ever,13 inadvertent automatic shutdowns (scrams). Nine of these were due to operator errors (12 utility operator trainees and 4 UW trainees during the year). Two were due to noise spikes from bumping control element drive or instrument channel cceonents while loading samples, and two were due to instrument failure. A de';ription of each of these events is inc"cated be-low in chronoligical or.er.

On one additional occasion (24 October 1978),

the cperator on duty manually scrammed the reactor when the log-N period channel indication drifted downscale after reaching a level power. An in-vestigation indicated the insulation resistance of the detector had de-creased due to moisture buildup.

20 July 1978 - Tra' ne= turned picoammeter #1 range switch to a lower range while intending to switch to the highest range to fire a pulse.

15 September 1978 -- Trainee failed to uprange #1 picoammeter in a timely fashion while increasing power level.

15 September 1978 -- Control blade #1 drive bumped while loading a sanple into irradiation position. The blade was knocked loose from its magnet.

10 and 12 January 1979 -- Trainee turned range switch on #1 picoam-meter in wrong direction while increasing power level.

16 Janua.y 1979 -- Period trip due to trainee increasing power level too rapidly as log-N period channel came on scale.

18 January 1979 -- Trainee failed to uprange #1 picoammeter in time while increasing power level.

1 February 1979 -- Trainee failed to uprange #2 picoammeter in time while increasing power level (had changed #1 in time).

6 February 1979 -- Period trip from noise induced in channel when cables were bumped during sample loading. A second trip from the channel the same day while level at full power led to further investigation which showed a decrease in insulation mistance at the input to the instrument.

This channel becomes sensitive to ground loop noise when the insulatinn resistance between electrodes or between the detector can and the water-proof housing decreases below about 10 ohms.

In this case, the insula-Lion resistance of the log diode fe' dback element had decraased to about 10" chms, causing extreme noise sensitivity.

79b i

-ut

_g_

16 March 1979 -- Trip from both #1 and #2 picoammeters when operator failed to uprange in time during a rapid power increase.

5 April 1979 -- Trip from both picoammeters when setting up for pulse mode.

Reactor was level at 300 watts with all permissives for pulse mode met. The operator was preparing to initiate a pulse.

The pulsing switch was stuck in the actuated position because of mechanical binding. When the mode switch was turned into square wave position (intermediate between manual and pulse positions), the transieat rod fired, initiating the pulse be_ fore the power level scram was defeated ~ by the mode switch and pulsing interlocks. The switch housing was modified to prevent recurrence.

14 June 1979 -- Operator failed to downrange picoammeter #1 in time while increasing power level because his attention was on period channel at that time.

It should ce noted that #1 picoammeter is involved in most of the '

operator error trips.

This is not due to a deficiency in that instrument but to the fact that it is usually the first range switch to be switched by the operator.

D.

MAINTENANCE OPERATIONS Ordinary preventative maintenance was performed on equipment and re-sulted in acceptable performance except for two items of corrective main-tenance on the log-N period channel detailed in section C above. There were no reportable maintenance operations.

E.

CHANGES IN THE FACILITY OR PROCEDURES PURSUANT TO SECTION 50.59 0F i0 CFR PART 50 There were none.

F.

RADI0 ACTIVE WASTE DISPOSAL 1.

Solid Waste There was no solid waste trans ferred out of the laboratory during the year.

2.

Liquid llaste Table 1 shows the record of liquid waste disposal during the fiscal year.

3.

Particulate and Gaseous Radioactivity Released tg_ the Atmosphere Table 2 presents information on stark activity disc.'1arged during the year.

-fO

,,, 7, r

TABLE 1 LIQUID WASTE TO SANITARY SEWER 11 SEPT 78 7 FEB 1979 5 JUNE 1979 TOTAL i

TOTAL ACTIVITY DISCHARGED (Microcuries) 7.00 5.48 177.1 189.St LIQUID QUANTITY (Gallons) 950.

800.

900.

2650.

0 Ra

- MPC USED - 4x10-AMOUNT (pCi) 1.33 0

0.42 1.7C CONC (pCi/ml) 1.48x10 0

4.7x10

-8 9

06

-4 Rt

- MPC USED - 4x10 l

AMOUNT (pCi) 0 9.3x10, 2 0

9.3x10-CONC (pCi/ml) 0 1.0x10 0

Co

- MPC USED - 1x10' AMOUNT (pCi) 2.90 0.43 0.62 3.95 CONC

( pCi/ml) 3.22x10 4.73x10-9

-9

-8 6.83x10 65

-3 Zn

- MPC USED - 3x10 AMOUNT (pCi) 2.09 1.42 0

3.51 CONC (pCi/ml) 2.32x10 1.58x10~

-8 0

-3 Mn

- MPC USED - 4x10 AMOUNT (pCi) 0.37 0

0.14 0.51 CONC (LCi/ml) 4.11x10'9 0

1.6xin'9 Co

- MPC USED - 4x10-AMOUNT (pCi) 0.31 0

0.29 0.60 CONC (pci/nl) 3.41x10 0

3.2x10

_g 9

P! - MPC USED - 9x10' AMOUNT (pCi) 0 3.63 32.6 CONC (pCi/ml) 4.03x10'8

~7 36.23 0

3.Sx10 Fe -MPC USED - 2x10-3 AMOUNT (pCi) 0 0-2.60 2.60 CONC (pCi/ml) 0 0

2. Mx1 ')

,g

-2 Fe

- MPC USED - 2x10 AMOUNT (pCi) 0 0

140.5 140.5 CONC

(;.C i /ml )

1.Mx10'6 Average,ncentration at point of release to sewer = 1.89x10 -5 na tural raaicactivity).

Ci/ml (includes Average daily sewage flow for dilution = 2 37x10 ga ll ons.

Average concentration after dilution = 5.79x10' uCi /nl.

q C, h l, b

-11 TABLE 2 EFFLUENT FROM STACK 1.

particulate Activity There was no discharge of particulate activity in excess of background levels.

2.

Gaseous Activity - All Argon 41 Activity Maximum Instantaneous Average Stack Discharged Month (Curies)

Concentratign Concentratign MPC Used uCi/ mix 10-pCi/ mix 10-pCi/ml July 78 0.1327 6.0 7.18 2.4x10-5 August 0.0125 0.3 0.72 September 0.0009 0.08 0.05 October 0.1486 1.8 8.64 Noveiber 0.1605 1.8 9.14 December 0.1075 1.6 5.69 January 79 0.0847 0.7 5.00 Februa ry 0.0777 0.4 4.80 March 0.0774 0.6 4.20 April 0.1283 0.9 7.58 May 0.0850 1.0 7.34 June 0.1990 1.0 11.10 TOTAL 1.215 6.0x10 Maximum 5.74x10 Yearly Average

-6

-8 The.'1PC value above is that calculated in the SAR to be equivalent to 3x10"8 pCi/ml in the area surrounding the laboratory.

/..a G.

SUW4ARY 0_F_ RADIATION EXPOSURES (1 July 1978 - 14 April 1979) fio significant exposure of personnel occurred due to operation of the reactor.

For occupationally exposed personnel, the highest annual whole body dose was 145 mrems, while the highest extremity dose for the entire year was 440 mrems.

For laboratory students, the highest annual whole body dose was 20 mrems.

ilo facility visitor received any measurable dose.

Routine radiation and contamination surveys of the fccility revealed no areas of high e.posure rates or contamination.

H.

RESULTS Z ENVIRONiiENTAL SURVEYS The er,vironmental monitoring program at Wisconsin censists of thermo-luminescert dosimeters (LiF TLD service from Eberline) located in the area surrounding the Reactor Laboratory.

The table below lists doses for persons continuously in the area for representative dosimeter readings.

Annual Dose Data-Er.vironmental Monitors Location Average Dose Rate-mrem / week Inside Wall of Reactor Laboratory 2.33 Inside Reactor Laboratory Stack

.87 Highest Dose Outside Reactor Laboratory (Reactor Lab roof entrance window: Monitor adjacent to stone surface) 2.27 Highest Dose in Occupied tionrestricted area (third floor classroom facing away from Reactor Lab)

.61 Average Dose in Occupied Nonrestricted Area

.42 Avcrage Dose in All Unrestricted Areas (29 Monitor Points)

.58

- r 7, 21

-c I.

PUBLICATIONS AND PRESENTATIONS ON WORK BASED ON REACTOR USE Dairy Science N. A. Jorgensen. Two papers have been sutmitted for publication.

Engineering Experiment Station (Energy Storage Project)

V. Mizutani, K. T. Hartwig, R. W. Hopper, T. B. Massalski, " Low Temperature Specific Heats of Glassy Pd1 Si Cu Alloys", to be published in Journal of Aoplied Physics Letters in/x yAugust$978.

x Mechanical Engineering G. L. Borman, " Heterogeneous Engine In-Cylinder Mixing Measurtments Using a Tracer Technique--Part 2", Department of Energy Report C00-4492-2, Ma rch, 1979.

A. J. Jessel, PhD Thesis, " Measurement of Fluid Motion in a Diesel Engine Cylindar by Use of a Tracer Gas Technique", May,1979 Medicine M. C. Shults, S. J. Updike, P. M. Treichel, and I. U. Treichel, "High Effi-ciency Oxford Type Oxygenator Based on Hemodialysis and fransmemt,rane Cata-lysis of Hydrogen Peroxide", Trans. Ame. Soc. Arti f. Int. Organs, 20, 286-292, 197,.

-~

S. J. Updike, M. Y.-D.

Chen, M.- Shults, " Membrane Oxygenator Based on Trans-membrane Catalysis of Hydrogen Peroxide.

Trans. Am. Soc. Arti f. Int.

Organs, M. 40;-497, 1977.

M.Y.-D Chen, M. C. Shults, and S. J. Updike, " Rotating Disk Membrane Oxygenator Based on Transmembrane Catalysis of Hydrogen Peroxide", Trans.

Am. Soc. Arti f. Organs, 24, 632-636, 1978.

Metalluriqical and Mineral Enaineering Ali A. Nayeb Hashemi, PhD preliminary report.

R. C. Voigt and C. R. Loper, Jr., "A Technique for Measuring Tungsten Con-tamination During GTA Welding", to be presented at American Welding Society Con ference, 1980.

Radiolocy - Human Oncology _

W. S. Kan, A. L. Wiley.

D. Moran, G. Wirtanen, T. A. Lang, and R. J. Cashwell,

" Detection and Quantitition of High Z Elements in Human Sarcomata by Multi-Energy Computerized Tomographic Scanning and Neutron Activation Analysia",

submitted to the American Journal of Roentgenology.

Soil Science R. D. Koons and P. A. Helmke, " Neutron Activation Analysis of Standard Soils",

Soil Science Society of A merica Journal 42, pp 237-240 (1978).

A. C. Stamm, M. S. Thesis, " Trace Elements in Whole Shales and Selected Shale Components", 1978.

n r; t-t ut

. Soil Science (Continued)

R. D. Koons and P. A. Helmke, " Control of Trace Element Concentrations by Iron Oxides during Rock Weathering".

Presented at Annual Meeting of Ameri-can Society of Agronomy, Chicago, IL, December,1978.

P. A. Helmke and R. D.

Koons, " Behavior of Trace and Major Elements During Early Stages of Weathering of Diabase and Granite".

Presented at ilth Inter-national Society of Soil Science, Edmonton, Alberta, Canada, July,1978.

University-Industry Research Program Reports in preparation.

Water Chemistry A. Andren, " Mass Balance and Speciation of Arseric in the Menominee River, Wisconsin". Project report to U.S.E.P. A., Athens. Georgia.

In preparation.

A. Andren, J. Hendricks, "Menominee-Marinette Sediment Investigation".