- 05000338/LER-1979-135, Forwards LER 79-135/03L-0 + (11:25:08, 4 January 2025)
- 05000368/LER-1979-084-03, /03L-0:on 790927,during Mode 2 Operation,Control Element Assembly 46 Dropped to Lower Electrical Limit.Cause Not Stated.Gripper Voltage Was Increased to Facilitate Rod Withdrawal.Rod Was Realigned to Group Average + (11:25:11, 4 January 2025)
- ML19254E300 + (11:25:16, 4 January 2025)
- 05000368/LER-1979-083-03, /03L-0:on 790926,during Mode 2 Operation,Rod 46 Dropped Four Times to Lower Electrical Limit.Cause Not Stated.Voltage to CEDM Gripper Coils Was Increased & Rod Exercised Successfully.Control Element Assembly Realigned + (11:25:19, 4 January 2025)
- ML19254E298 + (11:25:21, 4 January 2025)
- ML19254E297 + (11:25:23, 4 January 2025)
- 05000368/LER-1979-075-03, /03X-1:on 790822,during Mode 1 Operation,Data Link from Control Element Assembly Cluster to B Core Protection Computer Dropped,Resulting in B Channel Tripping.Caused by Failed Optical Amplifier.Data Link Was Repaired + (11:25:25, 4 January 2025)
- ML19254E294 + (11:25:30, 4 January 2025)
- ML19254E293 + (11:25:32, 4 January 2025)
- ML19254E292 + (11:25:34, 4 January 2025)
- ML19254E290 + (11:25:40, 4 January 2025)
- ML19254E289 + (11:25:41, 4 January 2025)
- ML19254E287 + (11:25:42, 4 January 2025)
- 05000338/LER-1979-134-03, /03L-0:on 790928,six Valves Failed to Close on First Signal of Containment Depressurization Test But Did So on Second Signal.Cause Undetermined.Valves Will Be Rechecked & Repaired as Necessary + (11:25:45, 4 January 2025)
- ML19254E285 + (11:25:47, 4 January 2025)
- ML19254E284 + (11:25:49, 4 January 2025)
- 05000325/LER-1979-072-03, /03L-0:on 791003,main Steam Line High Radiation Instrument D12-RM-K603A Intermittently Spiked.Caused by Loose Condition of Voltage Cable,Resulting in Poor Contact. Connector Removed & Cleaned + (11:25:51, 4 January 2025)
- ML19254E282 + (11:25:53, 4 January 2025)
- 05000338/LER-1979-134, Forwards LER 79-134/03L-0 + (11:25:55, 4 January 2025)
- ML19254E279 + (11:25:58, 4 January 2025)
- ML19254E278 + (11:25:58, 4 January 2025)
- ML19254E277 + (11:26:05, 4 January 2025)
- 05000325/LER-1979-072, Forwards LER 79-072/03L-0 + (11:26:08, 4 January 2025)
- ML19254E273 + (11:26:10, 4 January 2025)
- ML19254E272 + (11:26:12, 4 January 2025)
- ML19254E271 + (11:26:14, 4 January 2025)
- 05000325/LER-1979-076-03, /03L-0:on 791002,valve E11-F068B Failed to Open. Caused by Contacts Sticking in Relay Ri in Position Modulator,Resulting in Constant Close Signal.Relay Freed & Replacement Ordered + (11:26:16, 4 January 2025)
- ML19254E269 + (11:26:19, 4 January 2025)
- ML19254E268 + (11:26:21, 4 January 2025)
- ML19254E267 + (11:26:22, 4 January 2025)
- ML19254E266 + (11:26:24, 4 January 2025)
- 05000325/LER-1979-076, Forwards LER 79-076/03L-0 + (11:26:26, 4 January 2025)
- ML19254E262 + (11:26:31, 4 January 2025)
- ML19254E261 + (11:26:33, 4 January 2025)
- ML19254E260 + (11:26:33, 4 January 2025)
- ML19254E259 + (11:26:37, 4 January 2025)
- ML19254E258 + (11:26:42, 4 January 2025)
- ML19254E257 + (11:26:44, 4 January 2025)
- ML19254E256 + (11:26:46, 4 January 2025)
- ML19254E255 + (11:26:48, 4 January 2025)
- 05000325/LER-1979-069-03, /03L-0:on 790926,reactor Core Isolation Cooling Turbine Trip Alarm Annunciated.Caused by Tripping of Local Mechanical Trip as Result of Employee Dropping Something on Latch.Covers Being Installed + (11:26:49, 4 January 2025)
- ML19254E253 + (11:26:52, 4 January 2025)
- ML19254E251 + (11:26:55, 4 January 2025)
- 05000219/LER-1979-035-03, /03L-0:on 790926,during Normal Operation,Reading on Main Steam Line Radiation Monitor Lower than Other Three Monitors.Caused by Drift of Zero Setpoint of Amplifier in Monitor.Setpoint Reset to Zero + (11:26:57, 4 January 2025)
- ML19254E248 + (11:26:59, 4 January 2025)
- 05000325/LER-1979-069, Forwards LER 79-069/03L-0 + (11:27:01, 4 January 2025)
- 05000346/LER-1979-095-03, /03L-0:on 790925,auxiliary Feed Pump Turbine Steam Inlet Valve MS106 on Sys 1 Lost Its Indication.Caused by Loose Lamp Retainer Ring Which Grounded & Blew Control Power Fuse.Ring Was Tightened & Fuse Replaced + (11:27:04, 4 January 2025)
- 05000219/LER-1979-035, Forwards LER 79-035/03L-0 + (11:27:09, 4 January 2025)
- 05000346/LER-1979-095, Forwards LER 79-095/03L-0 + (11:27:11, 4 January 2025)
- ML19254E240 + (11:27:13, 4 January 2025)
- ML19254E239 + (11:27:14, 4 January 2025)