Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000346/LER-1978-004, Forwards LER 78-004/03L-0 + (21:52:19, 31 December 2024)
- ML19326A182 + (21:52:21, 31 December 2024)
- 05000346/LER-1978-005-03, /03L-0:on 780106,auxiliary Feed Pump Turbine 1-1 Speed Control Lost & Declared Inoperable.Caused by Short Circuits & Blown Fuses Due to Design Deficiency.Higher Current Rated Relays Installed & Circuit Modified + (21:52:22, 31 December 2024)
- ML19326A180 + (21:52:24, 31 December 2024)
- 05000346/LER-1978-005, Forwards LER 78-005/03L-0 + (21:52:25, 31 December 2024)
- ML19326A177 + (21:52:27, 31 December 2024)
- 05000346/LER-1978-006-03, /03L-0:on 780107,computer Alarm Indicated That Steam & Feedwater Rupture Control Sys Steam Generator to Feedwater Differential Pressure Channel 1 Had Tripped.Caused by Component Failure.Input Buffer 1-3 in Channel 1 Replaced + (21:52:28, 31 December 2024)
- ML19326A175 + (21:52:29, 31 December 2024)
- ML19326A174 + (21:52:31, 31 December 2024)
- 05000346/LER-1978-039-03, /03L-0:on 780417,containment High Radiation Channel 4 Setpoint Out of Tolerance.Caused by Component Failure.Bistable Drifted from Manual Setpoint.Setpoint for Channel 4 Adjusted to Value within Tolerance + (21:52:32, 31 December 2024)
- 05000346/LER-1978-006, Forwards LER 78-006/03L-0 + (21:52:34, 31 December 2024)
- 05000346/LER-1978-039, Forwards LER 78-039/03L-0 + (21:52:35, 31 December 2024)
- ET 19-0020, Supplemental Response to Request for Additional Information Revision to Technical Specification 3.3.5, Loss of Power (LOP) Diesel Generator (DG) Start Instrumentation + (21:52:37, 31 December 2024)
- AEP-NRC-2019-58, Core Operating Limits Report, Revision 0 + (21:52:37, 31 December 2024)
- 05000346/LER-1978-007-03, /03L-0:on 780109,during Monthly Surveillance Test ST 5081.01,diesel Generator 1-1 Tripped on High Crankcase Pressure.Caused by Dirty Crankcase Vent Oil Collector.Vent Oil Collector Disassembled & Cleaned + (21:52:39, 31 December 2024)
- ML19326A160 + (21:52:40, 31 December 2024)
- ML19326A159 + (21:52:42, 31 December 2024)
- ML19326A158 + (21:52:43, 31 December 2024)
- 05000346/LER-1978-007, Forwards LER 78-007/03L-0 + (21:52:45, 31 December 2024)
- 05000346/LER-1978-009-03, /03L-0:on 780112,component Cooling Water Heat Exchanger 1-1 Outlet Isolation Valve SW 1424 Declared Inoperable.Caused by Component Failure.Solenoid Valve in Control Scheme Found Burned Out.Unit Removed + (21:52:47, 31 December 2024)
- ML19326A152 + (21:52:49, 31 December 2024)
- ML19326A151 + (21:52:50, 31 December 2024)
- ML19326A150 + (21:52:51, 31 December 2024)
- 05000346/LER-1978-009, Forwards LER 78-009/03L-0 + (21:52:52, 31 December 2024)
- ML19326A147 + (21:52:54, 31 December 2024)
- 05000346/LER-1978-010-03, /03L-0:on 780115, Reactor Coolant Pump Monitor on Channel 1 Found Out of Tolerance & Reactor Protection Sys Declared Inoperable.Caused by Defective Module.New Module Calibr & Installed + (21:52:55, 31 December 2024)
- ML19326A145 + (21:52:57, 31 December 2024)
- 05000346/LER-1978-010, Forwards LER 78-010/O3L-0 + (21:52:58, 31 December 2024)
- 05000346/LER-1978-011-03, /03L-0:on 780116,during Surveillance Test,Decay Heat Pump 1-1 Failed to Start.Caused by Fuses in Breaker for Decay Heat Motor Failing to Make Proper Contact.Control Power Fuese Pulled & Reinserted.Pump Returned to Svc + (21:53:00, 31 December 2024)
- ML19326A140 + (21:53:01, 31 December 2024)
- 05000346/LER-1978-011, Forwards LER 78-011/03L-0 + (21:53:03, 31 December 2024)
- ML19326A137 + (21:53:05, 31 December 2024)
- ML19326A136 + (21:53:07, 31 December 2024)
- ML19326A135 + (21:53:08, 31 December 2024)
- ML19326A133 + (21:53:09, 31 December 2024)
- ML19326A132 + (21:53:10, 31 December 2024)
- ML19326A130 + (21:53:12, 31 December 2024)
- ML19326A131 + (21:53:12, 31 December 2024)
- ML19326A129 + (21:53:13, 31 December 2024)
- ML19326A127 + (21:53:14, 31 December 2024)
- ML19326A126 + (21:53:15, 31 December 2024)
- ML19326A124 + (21:53:15, 31 December 2024)
- ML19326A123 + (21:53:16, 31 December 2024)
- ML19326A122 + (21:53:17, 31 December 2024)
- 05000346/LER-1978-078-03, /03L-0:on 780713,ST 5099.08 & ST 5099.11 Not Performed Per Tech Spec 4.0.5 & Not Included in Computer Schedule.St 5099.08 Incorporated in Test Program on 780727. Passive Valves Identified & Operational Log Used + (21:53:19, 31 December 2024)
- ML19326A120 + (21:53:20, 31 December 2024)
- ML19326A117 + (21:53:21, 31 December 2024)
- 05000346/LER-1978-078, Forwards LER 78-078/03L-0 + (21:53:22, 31 December 2024)
- ML19326A114 + (21:53:24, 31 December 2024)
- 05000346/LER-1978-077-03, /03L-0:on 780710,component Cooling Water Pump Vibration Readings Exceeded Max Limits.Caused by Component Failure.Pump Bearings Found Failing.Bearing to Shell Clearance Increased & Pump Bearing Replaced + (21:53:25, 31 December 2024)
- ML19326A111 + (21:53:27, 31 December 2024)