- 05000295/LER-1979-003-01, /01T-0 on 790109:Westinghouse Results of Feb 1978 ECCS Model Analysis Determined That Fq Limit Should Be 1.86 Rather than the Current Limit of 2.02.Plant Operations Modified to Adhere to New Limit + (16:58:07, 3 January 2025)
- ML19261A851 + (16:58:08, 3 January 2025)
- 05000295/LER-1979-003, Forwards LER 79-003/01T-0 + (16:58:10, 3 January 2025)
- ML19261A848 + (16:58:11, 3 January 2025)
- 05000295/LER-1978-130-99, /99X-0 on 781205:two Safety Injections Ocurred from False Steam Pressure Differential Signals.False Signals Caused by Shocks from Water Hammers + (16:58:13, 3 January 2025)
- ML19261A846 + (16:58:14, 3 January 2025)
- ML19261A845 + (16:58:15, 3 January 2025)
- 05000295/LER-1978-130, Forwards LER 78-130/99X-0 + (16:58:20, 3 January 2025)
- ML19261A842 + (16:58:21, 3 January 2025)
- ML19261A840 + (16:58:22, 3 January 2025)
- 05000265/LER-1978-039-03, /03L-0 on 781218:test Results Found HPCI Initiation Switches Associated W/Drywell Pressure Instruments Not in Accordance W/Tech Specs.Caused by Procedural Inadequacy;Switches Excluded from Test Program + (16:58:24, 3 January 2025)
- 05000254/LER-1978-033-03, /03L-0 on 781219:during Automatic Isolation of Ventilation Sys,Inlet Isolation Dampers 1-5741 a & B Failed to Close.Pilot Solenoid on Air Operator of Damper Valves Stuck & Failed to Supply Air Signal Needed to Close Valve + (16:58:26, 3 January 2025)
- ML19261A836 + (16:58:27, 3 January 2025)
- ML19261A835 + (16:58:28, 3 January 2025)
- 05000265/LER-1978-039, Forwards LER 78-039/03L-0 + (16:58:29, 3 January 2025)
- 05000254/LER-1978-033, Forwards LER 78-033/03L-0 + (16:58:31, 3 January 2025)
- ML19261A828 + (16:58:34, 3 January 2025)
- 05000295/LER-1978-140-03, /03L-0 on 781227:steam Generator Pressure Channel 1P-546 Pegged High Several Times.Caused by Detuned Oscillator in Transmitter Model 50EP 1041BCXA.Oscillator Replaced & Sys Returned to Normal + (16:58:37, 3 January 2025)
- 05000295/LER-1978-027-03, /03X-1 on 780402:steam Flow Channel 1F522 Failed Low Due to Plugging of High Side Sensing of Transmitter While Sealing Valve Steam Leak.Valve Was Replaced + (16:58:42, 3 January 2025)
- 05000295/LER-1978-140, Forwards LER 78-140/03L-0 + (16:58:46, 3 January 2025)
- 05000295/LER-1978-027, Forwards LER 78-027/03X-1 + (16:58:50, 3 January 2025)
- ML19261A821 + (16:58:52, 3 January 2025)
- ML19261A820 + (16:58:53, 3 January 2025)
- ML19261A819 + (16:58:54, 3 January 2025)
- 05000295/LER-1978-144-03, /03L-0 on 780925:generator 1NM-441B Output Out of Tolerance;Low 2.5%.Caused by Instrument Drift Resulting in Nontolerance of Function Generator Model 113.Model Recalibrated & System Returned to Normal + (16:58:56, 3 January 2025)
- ML19261A817 + (16:58:58, 3 January 2025)
- ML19261A816 + (16:58:59, 3 January 2025)
- 05000295/LER-1978-138-03, /03L-0 on 781224:during Normal Operation Component Cooling Liquid Radiation Monitor 1RE-0017 Failed Low & Was Taken Out of Svc.Cause Was Defective High Voltage Power Supply + (16:59:01, 3 January 2025)
- 05000318/LER-1979-003-01, /01T-0 on 790120:during Normal operation,22A Lower Seal Temp Alarm Was Received & RCS Leak Rate Increased. Caused by Cracked Weld on 22A Lower Seal Pressure Sensing Line.Design Change Is in Progress + (16:59:04, 3 January 2025)
- 05000295/LER-1978-144, Forwards LER 78-144/03L-0 + (16:59:15, 3 January 2025)
- ML19261A811 + (16:59:17, 3 January 2025)
- 05000295/LER-1978-138, Forwards LER 78-138/03L-0 + (16:59:19, 3 January 2025)
- 05000318/LER-1979-003, Forwards LER 79-003/01T-0 + (16:59:21, 3 January 2025)
- 05000254/LER-1978-032-03, /03L-0 on 781218:calibr & Functional Test for Drywell Pressure Instruments PS1-1001-89 a Thru D Found Not in Accordance W/Tech Specs.Caused by Instrument Drift + (16:59:25, 3 January 2025)
- ML19261A804 + (16:59:31, 3 January 2025)
- ML19261A800 + (16:59:37, 3 January 2025)
- 05000254/LER-1978-032, Forwards LER 78-032/03L-0 + (16:59:39, 3 January 2025)
- 05000263/LER-1979-001, Forwards LER 79-001/03L-0 + (16:59:41, 3 January 2025)
- ML19261A795 + (16:59:42, 3 January 2025)