- 05000315/LER-1983-002, Forwards LER 83-002/03L-0 + (14:47:23, 26 May 2025)
- ML20071C177 + (14:48:37, 26 May 2025)
- 05000324/LER-1983-010-03, /03L-0:on 830119,during Plant Operation,Both Doors of Reactor Bldg 20-ft Elevation Personnel Air Lock Opened Simultaneously.Caused by Misalignment of Inner Door Due to Normal Wear Preventing Proper Bolt Engagement + (14:49:09, 26 May 2025)
- 05000318/LER-1983-006-03, /03L-0:on 830123,auxiliary Feedwater Actuating Sys Channel Zd for Steam Generator 21 Level Indicated Low.Caused by Failure of Level Transmitter 2-LT-1114A Due to Defective Zero Adjustment Potentiometer.Transmitter Replaced + (14:49:11, 26 May 2025)
- 05000315/LER-1983-001-03, /03L-0:on 830118,Unit 2 Auxiliary Cable Vault Experienced Inadvertent Carbon Dioxide Discharge,Resulting in Isolation of Unit 1 & 2 Carbon Dioxide Tanks.Valve Closed & Main Isolation Reopened + (14:50:36, 26 May 2025)
- 05000315/LER-1983-001, Forwards LER 83-001/03L-0 (Previously Submitted as Unit 2 LER 83-022/03L-0) + (14:50:42, 26 May 2025)
- 05000321/LER-1981-129-01, Torus to Reactor Bldg Vacuum Relief Isolation Valve Failed to Close.Caused by Water Accumulation in Reactor Bldg Pressure Sensing Lines, Due to Improper Installation.Design Change Implemented + (14:51:01, 26 May 2025)
- 05000416/LER-1983-031, Forwards LER 83-031/99X-0 + (14:51:10, 26 May 2025)
- ML20071B222 + (14:51:54, 26 May 2025)
- ML20071B052 + (14:52:11, 26 May 2025)
- 05000373/LER-1982-090-03, During Startup Test Procedure 17,mechanical Snubber Found Damaged.Caused by Application of Excessive Forces in Lateral Direction Causing Snubber to Bend or Twist.Snubber Replaced + (14:52:16, 26 May 2025)
- 05000373/LER-1982-090, Forwards Revised LER 82-090/03X-1 + (14:52:22, 26 May 2025)
- TXX-9403, Forwards Addl Info Re License Amend Request 93-003 Re Control Room HVAC Sys,Including Control Room Air Conditioning Sys,Per Discussions W/Nrc + (14:52:27, 26 May 2025)
- ML20071A953 + (14:52:30, 26 May 2025)
- 05000318/LER-1983-004, Forwards LER 83-004/03L-0 + (14:52:58, 26 May 2025)
- ML20070W260 + (14:54:01, 26 May 2025)
- TAC:48501 + (14:54:07, 26 May 2025)
- ML20070V984 + (14:54:35, 26 May 2025)
- ML20070V631 + (14:54:52, 26 May 2025)
- 05000416/LER-1982-059-01, While Performing RHR High to Low Pressure Interface Valve Leakage Test,Setpoints for RHR Injection Valve Differential Pressure Switches Found Greater than Tech Specs.Caused by Misinterpretation + (14:55:02, 26 May 2025)
- 05000416/LER-1982-059, Forwards Updated LER 82-059/01X-1 + (14:55:05, 26 May 2025)
- 05000260/LER-1982-035-03, During Refueling Outage, While Performing Surveillance Insp 4.6.H-2,upper Mechanical Snubber on Main Steam Line D Found Inoperable.Snubber Replaced.Engineering Analysis Encl + (14:55:45, 26 May 2025)
- 05000366/LER-1980-073-03, Hydrogen Combiner B Failed to Start During Test.Caused by Temp Controller Setpoint Too Close to Sys Trip Setpoint.Procedure Revised to Lower Controller Setpoint + (14:55:57, 26 May 2025)
- 05000366/LER-1980-073, Forwards Updated LER 80-073/03X-1 + (14:56:00, 26 May 2025)
- 05000281/LER-1981-052-03, Valve MOV-SW-202A Failed to Close Due to Grounded Motor.Grounding Caused by Flooding in Sump.Motor Replaced + (14:56:09, 26 May 2025)
- 05000321/LER-1979-076-01, Plant Engineering Personnel Confirmed NSSS Vendor Info Re Cable Separation Irregularities in HPCI Sys.Caused by Design Error.Cable Will Be Rerouted Per Design Change Request 79-379 + (14:56:18, 26 May 2025)
- 05000321/LER-1979-076, Forwards Updated LER 79-076/01X-1 + (14:56:21, 26 May 2025)
- 05000366/LER-1980-130-03, Primary Containment Hydrogen & Oxygen Analyzer Found Inoperable.Caused by Analyzer Being Out of Calibr.Analyzer Calibr + (14:56:28, 26 May 2025)
- 05000366/LER-1980-130, Forwards Updated LER 80-130/03X-1 + (14:56:31, 26 May 2025)
- ML20070U803 + (14:56:34, 26 May 2025)
- 05000260/LER-1982-026, Forwards Updated LER 82-026/03X-2 + (14:56:52, 26 May 2025)
- TAC:48295 + (14:58:07, 26 May 2025)
- ML20070T568 + (14:58:24, 26 May 2025)
- 05000445/LER-1991-003-01, Advises That LER 91-003-01 Re Less than Adequate Procedure Review Leading to Failure to Fully Satisfy ASME Section XI Testing Requirements Delayed from 910329 to 0429 + (14:58:48, 26 May 2025)
- ML20070T376 + (14:58:52, 26 May 2025)
- 05000305/LER-1982-030-01, Instrumentation Lines Found Capped,Rendering Containment narrow- & wide-range Pressure Transmitters & Containment Vacuum Breakers Inoperable.Caused by Personnel Error.Caps Removed + (14:59:16, 26 May 2025)
- 05000305/LER-1982-030, Forwards Updated LER 82-030/01X-1 + (14:59:19, 26 May 2025)
- 05000346/LER-1982-064, Forwards Revised LER 82-064/03X-1 + (14:59:44, 26 May 2025)
- TAC:51033 + (14:59:54, 26 May 2025)
- ML20070S698 + (15:00:03, 26 May 2025)
- ML20070S398 + (15:00:31, 26 May 2025)
- SNRC-2169, Advises of Listed Clarification to Util Re Resignation of Jc Brons from Position of Executive Vice President of Shoreham Decommissioning Project + (15:01:00, 26 May 2025)
- A08646, Revises 900703 Response to NRC Bulletin 90-001, Loss of Fill-Oil in Transmitters Mfg by Rosemount. Training of Instrumentation & Control Personnel Completed in Jul 1990. Revised Operability Acceptance Criteria Listed on Encl + (15:02:40, 26 May 2025)
- ML20070Q546 + (15:03:45, 26 May 2025)
- 05000278/LER-1982-022, Revised LER 82-022/01X-1:on 821025-1102,RHR HX 3D Leaked Slightly Radioactive Water Into Intake Structure.Caused by Expansion Bellows Leak Between Inner Floating Head & Drain. HX Repaired + (15:04:12, 26 May 2025)
- BECO-94-054, Provides Response to Request for Addl Info for Relief Requests PRR-17,PRR-18 & PRR-19.Encl B Provides Revised Relief PRR-17.Encl C Provides Informational Drawing Packages for Revised PRR-17,Rev 1,PRR-18 & PRR-19 + (15:05:21, 26 May 2025)
- ML20070P365 + (15:06:00, 26 May 2025)
- ML20070N316 + (15:07:38, 26 May 2025)
- ML20070N306 + (15:07:41, 26 May 2025)
- ML20070M962 + (15:08:06, 26 May 2025)
- 05000272/LER-1982-008, Supplemental LER 82-008/03X-1:on 820126,boric Acid Concentrations in Boric Acid Storage Tanks 11 & 12 Found Below Tech Spec Limit.Caused by Dilution of Concentration by Flushing Water in Tank Following Maint.Boric Acid Added + (15:08:09, 26 May 2025)