- TAC:56336 + (23:33:26, 25 May 2025)
- 05000366/LER-1981-093-03, /03X-1:on 811006,while Performing Normal Surveillance,Pressure Switch 2B21-NO15D Found to Actuate at 5 Psig Lower than Tech Spec Limit.Caused by Setpoint Drift. Pressure Switch Recalibr + (23:33:33, 25 May 2025)
- IR 05000315/1999010 + (23:34:22, 25 May 2025)
- IR 05000313/2001006 + (23:34:42, 25 May 2025)
- ML20112F099 + (23:34:56, 25 May 2025)
- 05000254/LER-1991-003-02, Forwards LER 91-003-02.Containment Atmosphere Monitoring Piping & Mark I Support Installation Work Will Be Completed Prior to Startup from Current Forced Outage Q2F41 + (23:36:24, 25 May 2025)
- TAC:55983 + (23:38:11, 25 May 2025)
- 05000352/LER-1996-006, :on 960207,control Room Emergency Fresh Air Sys Declared Inoperable.Caused by Flow Switch Coordination Deficiency.Flow Switches Adjusted,Station Guidance Revised & Site Staff Training Performed + (23:39:03, 25 May 2025)
- 05000298/LER-1996-003, :on 960320,single Train RCIC Sys Inoperable Due to Equipment Malfunction.Specific Cause of Failure Could Not Be Determined.Malfunctioning EGM Control Box Was Replaced + (23:39:13, 25 May 2025)
- 05000321/LER-1981-052-03, /03X-1:on 810621,LPCI Inverter B R44-S003 Tripped, Resulting in Loss of Power to Suction & Discharge Valves & LPCI Injection Valve.Caused by Defective Thermal Temp Switch in Inverter Leg.Switch Replaced + (23:39:24, 25 May 2025)
- ML20112C340 + (23:39:47, 25 May 2025)
- ML20112C267 + (23:39:54, 25 May 2025)
- ML20112B239 + (23:41:20, 25 May 2025)
- 05000346/LER-1982-008-03, /03X-1:on 820208,mechanical Penetration Room Pressure Gauge PDI-5000 Failed,Rendering Emergency Ventilation Sys Train 1-1 Inoperable.Caused by Ice Buildup on Transmitter Vent Line.Ice Removed + (23:42:22, 25 May 2025)
- 05000354/LER-1996-015, :on 960410,potential to Operate in Unanalyzed Condition Occurred.Caused by Original Design Calculation Deficiency.Appropriate Maximum UHS Temp Will Be re-evaluated + (23:43:16, 25 May 2025)
- ML20111B024 + (23:44:59, 25 May 2025)
- RA20-016, Corrected Drawing for One-Line Electrical Power Supply for Containment Vent System Final Integrated Plan + (23:46:09, 25 May 2025)
- PMNS20200260, NRC Webinar on Indian Point Nuclear Plant Decommissioning + (23:46:13, 25 May 2025)
- ML20108F052 + (23:47:43, 25 May 2025)
- 05000298/LER-1995-020, :on 951125,found That Drawing Change Process Deficiency Resulted in Noncompliance w/1CFR50 App R.Design Change Process Being Revised & Training Will Be Presented to Appropriate Design Personnel on Process Revs + (23:48:31, 25 May 2025)
- ML20108E749 + (23:48:35, 25 May 2025)
- ML20108D610 + (23:50:02, 25 May 2025)
- A002561, NPDES Permit PA0025615,issued to Duquesne Light Co + (23:50:55, 25 May 2025)
- 05000362/LER-1996-001, :on 960304,voltage Signal Actuation Loss Due to Inadvertent Relay Trip.Enhanced Turbine Startup Sequence by Slowing (from 2.5 Seconds to 8 Seconds) Operation of Trip/ Throttle Valve + (23:51:03, 25 May 2025)
- 05000368/LER-1981-014-03, /03X-1:on 810328,operator Insp Found Excessive Packing Leakage from Emergency Feedwater Pump & Water in Bearing Lubricating Oil.Caused by Excessive Shaft Packing Leakages During Pump Idle Time + (23:51:23, 25 May 2025)
- 05000368/LER-1981-013-03, /03X-1:on 810304,RCS Cold Leg Temp Indicator Discovered to Be Reading High.Caused by Defective Servo Motor.Motor Replaced.Indicator Calibr + (23:51:26, 25 May 2025)
- 05000293/LER-1996-003, :on 960403,RCICS Made Inoperable Due to Anomalies Noted During Testing.Caused by Malfunctioning Speed Control Sys Hydraulic Actuator (EG-R).EG-R Replaced & Rcics Declared Operable on 960405 + (23:52:00, 25 May 2025)
- TAC:53458 + (23:54:05, 25 May 2025)
- 05000369/LER-1996-001, :on 960203,manual Reactor Tripped When 1A RCP Upper Thrust Bearing Reached Administrative Limit of 195 Degrees.Caused by Unknown Equipment Failure.Associated Sys & Components Evaluated/Tested.Unit Returned to Svc on 960205 + (23:54:42, 25 May 2025)
- 05000368/LER-1979-047-04, /04X-1:on 790627,condenser Vacuum Pump Radiation Monitors 2RE0645 & 2RE0646 Inoperable for More than Seven Days.Caused by Moisture Buildup Due to Condensation.Heat Tracing Installed to Minimize Buildup + (23:55:18, 25 May 2025)
- 05000368/LER-1982-006-03, /03X-2:on 820212,17,0319 & 29,containment Isolation Valve 2CV-2061-2 for Reactor Bldg Sump Drain Failed to Close.Caused by Failing Actuator.Actuator Reassembled & Air Supply Line Relocated + (23:55:40, 25 May 2025)
- 05000400/LER-1996-002, :on 960117,failure to Perform Required Surveillance Testing During Planned Maint Outage in Oct 1994 Identified.Caused by Personnel Error.Personnel Involved in Procedure Counseled + (23:55:42, 25 May 2025)
- TAC:53266 + (23:57:26, 25 May 2025)
- 05000311/LER-1984-024, :on 841004,reactor Tripped Due to Turbine Generator Trip on Differential Relay Protection.Caused by phase-to-ground Fault on Stator Coils B-40 & B-41.Generator Replaced.Investigation Continuing + (23:58:08, 25 May 2025)
- NUREG-1102, Unexecuted Amend 7 to Indemnity Agreement B-75,revising Item 3 in Entirety as Listed.Tech Specs (NUREG-1102) Encl + (23:58:40, 25 May 2025)
- ML20107L150 + (23:58:44, 25 May 2025)
- ML20107L139 + (23:58:45, 25 May 2025)
- ML20107L124 + (23:58:47, 25 May 2025)
- 05000318/LER-1984-008-01, :on 841003,automatic Trip Occurred Due to Steam Generator Feed Pump (SGFP) 22 Trip.Possibly Caused by Spurious Fault in Common SGFP Control Circuitry.Sgfp Control Oil & Lube Oil Sys Checked + (23:58:49, 25 May 2025)
- 05000416/LER-1984-044, :on 841006,Div 1 Reactor Water Cleanup Sys Containment Isolated.Caused by Main Steam Line Temp Switch 5-amp Fuse Failure.Half Isolation Signal in Logic for Main Steam Line Isolation Valves Also Produced + (23:58:50, 25 May 2025)
- ML20107L050 + (23:58:54, 25 May 2025)
- ML20107L039 + (23:58:56, 25 May 2025)
- ML20107L033 + (23:58:58, 25 May 2025)
- ML20107L025 + (23:59:00, 25 May 2025)
- 05000395/LER-1984-044, :on 841002,following Removal of Two Fuses from Solid State Protection Sys Cabinet XPN-7020,relay Activated, Causing Train a RHR Suction Isolation Valves XVG-8702 a & B to Close.Caused by Drawing Errors + (23:59:03, 25 May 2025)
- ML20107K848 + (23:59:17, 25 May 2025)
- 05000325/LER-1996-004-01, :on 960321,standby Gas Treatment Sys Charcoal Testing to Pre & Post Sweep Temperature Not Performed.Caused by Vendor Interpretation of Reg Guide 1.52,rev 1.C/A: Testing Samples Completed on 960326 + (23:59:19, 25 May 2025)
- 05000483/LER-1984-011, :on 840704,containment Purge Isolation & Control Room Ventilation Isolation Signals Actuated by Radiation Alarm from Loss of Power to Radiation Elements GT-RE-31 & 33.Info Deleted + (23:59:23, 25 May 2025)
- ML20107K735 + (23:59:34, 25 May 2025)
- ML20107K710 + (23:59:36, 25 May 2025)
- 05000298/LER-1984-011, :on 840828,HPCI Overspeed Trip Control Valve Diaphragm Failed.Caused by Problem W/Procurement of Valve Diaphragms for Subj Control Valve Application. Preventative Maint Instituted + (23:59:44, 25 May 2025)