Amends 116 & 78 to Licenses NPF-39 & NPF-85,respectively, Changing Concentration of Calibr Gas Required for Calibr Hydrogen & Oxygen Analyzers & Support LGS Trip T-102
ML20107L025
Person / Time
Site: Limerick  
(NPF-039, NPF-085)
Issue date: 04/23/1996
From: Stolz J
Office of Nuclear Reactor Regulation
To:
Philadelphia Electric Co
Shared Package
ML20107L028 List:
References
NPF-39-A-116, NPF-85-A-078 NUDOCS 9604290133
Download: ML20107L025 (8)


Text

._-

.. - =. - -.

paarog$%

p UNITED STATES j

NUCLEAR REGULATORY COMMISSION 2

WASHINGTON, D.C 2006H001

.....,$ ' ~ '

PHILADELPHIA FLECTRIC COMPANY, DOCKET NO. 50-352 LIMERICK GENERATING STATION. UNIT 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.116 License No. NPF-39 1.

The Nuclear Regulatory Comission (the Comission) has found that:

A.

The application for amendment by Philadelphia Electric Company (the licensee) dated March 1,1995, as supplemented by letter dated April 16, 1996, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuance of this amendment will not be inimical to the comon defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

9604290133 960423 PDR ADOCK 05000352 P

PDR

2.

Accordihgly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-39 is hereby amended to read as follows:

Technical Specifications The Technical Specifications contained in Appendix A and the Environmental Protection Plan contained in Appendix B, as revised through Amendment No.116

, are hereby incorporated into this license.

Philadelphia Electric Company shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

3.

This license amendment is effective as of its date of issuance, to be implemented within 45 days.

FOR THE NUCLEAR REGULATORY COMMISSION

), h/U =-~

[JohnF.Stolz, Director Project Directorate I-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation l

Attachment:

Changes to the Technical Specifications Date of Issuance: April 23, 1996

i.

ATTACHMENT TO LICENSE AMENDMENT NO.116 FACILITY OPERATING LICENSE NO. NPF-39 DOCKET NO. 50-352 Replace the following page of the Appendix A Technical Specifications with the attached page.

The revised page is identified by Amendment number and contains vertical lines indicating the area of change.

Remove Insert 3/4 3-87 3/4 3-87 A

TABLE 4.3.7.5-1 ACCIDENT MONITORING INSTRUMENTATION SURVEILLANCE REOUIREMENTS r

CHANNEL CHANNEL j

INSTRUMENT CHECK CALIBRATION

n f

y 1.

Reactor Vessel Pressure M

R

[

2.

Reactor Vessel Water Level M

R z

3.

Suppression Chamber Water Level M

R 4.

Suppression Chamber Water Temperature M

R 5.

Suppression Chamber Air Temperature M

R 6.

Primary Containment Pressure M

R 7.

Drywell Air Temperature M

R w

8.

Drywell Oxygen Concentration Analyzer M

Q#

a w

9.

Drywell Hydrogen Concentration Analyzer M

Q*

10.

Safety / Relief Valve Position Indicators M

R 11.

Primary Containment Post LOCA Radiation Monitors M

R**

12.

North Stack Wide Range Accident Monitor ***

M R

3.

13.

Neutron Flux M

R R

R g

  • Using calibration gas containing:

Seven volume percent hydrogen, balance nitrogen.

l

    • CHANNEL CALIBRATION shall consist of an electronic calibration of the channel, not including the detector, 5

for range decades above 10 R/h and a one point calibration check of the detector below 10 R/h with an installed or portable gamma source.

      • High range noble gas monitors.
  1. Using calibration gas containing:

Seven volume percent oxygen, balance nitrogen.

I

o nog)&

UNITED STATES y-NUCLEAR REGULATORY COMMISSION f~~

WASHINGTON, D.C. 20666 4001

/

l PHILADELPHIA ELECTRIC COMPANY DOCKET NO. 50-353 LIMERICK GENERATING STATION. UNIT 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 78 License No. NPF-85 1.

The Nuclear Regulatory Comission (the Comission) has found that:

A.

The application for amendment by Philadelphia Electric Company (the licensee) dated March 1, 1995, as supplemented by letter dated April 16, 1996, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Comission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the

~

provisions of the Act, and the rules and regulations of the Comission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuance of this amendment will not be inimical to the comon i

defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-85 is hereby amended to read as follows:

Technical Specifications The Technical Specifications contained in Appendix A and the Environmental Protection. Plan contained in Appendix B, as revised through Amendment No. 78

, are hereby incorporated into this license.

Philadelphia Electric Company shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

3.

This license amendment is effective as of its date of issuance, to be implemented within 45 days.

FOR THE NUCLEAR REGULATORY COMilSSION

& W. b

[JohnF.Stolz, Director Project Directorate I-2 s

Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance: April 23, 1996 i

l I

. = -

1 ATTACHMENT TO LICENSE AMENDMENT NO. 78 FACILITY OPERATING LICENSE NO. NPF-85 DOCKET NO. 50-353 l

Replace the following page of the Appendix A Technical Specifications with the attached page. The revised page is identified by Amendment number and contains vertical lines indicating the area of change.

Remove Insert 3/4 3-87 3/4 3-87 I

l l

L L

I l

TABLE 4.3.7.5-I ACCIDENT MONITORING INSTRUMENTATION SURVEILLANCE REQUIREMENTS CHANNEL CHANNEL INSTRUMENT CHECK CALIBRATION 1.

Reactor Vessel Pressure M

R E

2.

Reactor Vessel Water Level M

R f

i 3.

Suppression Chamber Water Level M

R

~

g

[

4.

Suppression Chamber Water Temperature M

R 5.

Suppression Chamber Air Temperature M

R 6.

Primary Containment Pressure M

R 7.

Drywell Air Temperature M

R 8.

Drywell Oxygen Concentration Analyzer M

Qi 9.

Drywell Hydrogen Concentration Analyzer M

Q*

10.

Safety / Relief Valve Position Indicators M

R 11.

Primary Containment Post LOCA Radiation Monitors M

R**

12.

North Stack Wide Range Accident Monitor ***

M R

{

13.

Neutron Flux M

R

s
  • Using calibration gas containing:

i Seven volume percent hydrogen, balance nitrogen.

1

    • CHANNEL CALIBRATION shall consist of an electronic calibration of the channel, not including the detector, for range decades above 10 R/h and a one point calibration check of the detector below 10 R/h with an a

installed or portable gamma source.

      • High range noble gas monitors.
  1. Using calibration gas containir.g:

Sevan volume percent oxyeca, balance nitrogen.

I E.