Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
05000293/LER-1996-003, :on 960403,RCICS Made Inoperable Due to Anomalies Noted During Testing.Caused by Malfunctioning Speed Control Sys Hydraulic Actuator (EG-R).EG-R Replaced & Rcics Declared Operable on 960405 +, 05000293/LER-1996-003, :on 960403,RCICS Made Inoperable Due to Anomalies Noted During Testing.Caused by Malfunctioning Speed Control Sys Hydraulic Actuator (EG-R).EG-R Replaced & Rcics Declared Operable on 960405 +, 05000293/LER-1996-003, :on 960403,RCICS Made Inoperable Due to Anomalies Noted During Testing.Caused by Malfunctioning Speed Control Sys Hydraulic Actuator (EG-R).EG-R Replaced & Rcics Declared Operable on 960405 +, 05000293/LER-1996-003, :on 960403,RCICS Made Inoperable Due to Anomalies Noted During Testing.Caused by Malfunctioning Speed Control Sys Hydraulic Actuator (EG-R).EG-R Replaced & Rcics Declared Operable on 960405 +, 05000293/LER-1996-003, :on 960403,RCICS Made Inoperable Due to Anomalies Noted During Testing.Caused by Malfunctioning Speed Control Sys Hydraulic Actuator (EG-R).EG-R Replaced & Rcics Declared Operable on 960405 +, 05000293/LER-1996-003, :on 960403,RCICS Made Inoperable Due to Anomalies Noted During Testing.Caused by Malfunctioning Speed Control Sys Hydraulic Actuator (EG-R).EG-R Replaced & Rcics Declared Operable on 960405 +, 05000293/LER-1996-003, :on 960403,RCICS Made Inoperable Due to Anomalies Noted During Testing.Caused by Malfunctioning Speed Control Sys Hydraulic Actuator (EG-R).EG-R Replaced & Rcics Declared Operable on 960405 +, 05000293/LER-1996-003, :on 960403,RCICS Made Inoperable Due to Anomalies Noted During Testing.Caused by Malfunctioning Speed Control Sys Hydraulic Actuator (EG-R).EG-R Replaced & Rcics Declared Operable on 960405 +, 05000293/LER-1996-003, :on 960403,RCICS Made Inoperable Due to Anomalies Noted During Testing.Caused by Malfunctioning Speed Control Sys Hydraulic Actuator (EG-R).EG-R Replaced & Rcics Declared Operable on 960405 +, 05000293/LER-1996-003, :on 960403,RCICS Made Inoperable Due to Anomalies Noted During Testing.Caused by Malfunctioning Speed Control Sys Hydraulic Actuator (EG-R).EG-R Replaced & Rcics Declared Operable on 960405 +, 05000293/LER-1996-003, :on 960403,RCICS Made Inoperable Due to Anomalies Noted During Testing.Caused by Malfunctioning Speed Control Sys Hydraulic Actuator (EG-R).EG-R Replaced & Rcics Declared Operable on 960405 +, 05000293/LER-1996-003, :on 960403,RCICS Made Inoperable Due to Anomalies Noted During Testing.Caused by Malfunctioning Speed Control Sys Hydraulic Actuator (EG-R).EG-R Replaced & Rcics Declared Operable on 960405 +, 05000293/LER-1996-003, :on 960403,RCICS Made Inoperable Due to Anomalies Noted During Testing.Caused by Malfunctioning Speed Control Sys Hydraulic Actuator (EG-R).EG-R Replaced & Rcics Declared Operable on 960405 +, 05000293/LER-1996-003, :on 960403,RCICS Made Inoperable Due to Anomalies Noted During Testing.Caused by Malfunctioning Speed Control Sys Hydraulic Actuator (EG-R).EG-R Replaced & Rcics Declared Operable on 960405 +  and 05000293/LER-1996-003, :on 960403,RCICS Made Inoperable Due to Anomalies Noted During Testing.Caused by Malfunctioning Speed Control Sys Hydraulic Actuator (EG-R).EG-R Replaced & Rcics Declared Operable on 960405 +
0.0117 d (0.282 hours, 0.00168 weeks, 3.862075e-4 months)  +, 0.0119 d (0.286 hours, 0.0017 weeks, 3.91915e-4 months)  +, 0.0142 d (0.342 hours, 0.00203 weeks, 4.68015e-4 months)  +, 0.02 d (0.481 hours, 0.00286 weeks, 6.58265e-4 months)  +, 0.0106 d (0.254 hours, 0.00151 weeks, 3.481575e-4 months)  +, 0.0116 d (0.278 hours, 0.00166 weeks, 3.808805e-4 months)  +, 0.0152 d (0.366 hours, 0.00218 weeks, 5.011185e-4 months)  +  and 0.00231 d (0.0556 hours, 3.306878e-4 weeks, 7.61e-5 months)  +
April 29, 1996  +
1,996  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
23:52:00, 25 May 2025  +
Processing error"Processing error" is a predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> and represents errors that appeared in connection with improper value annotations or input processing.
Request  +
April 29, 1996  +
:on 960403,RCICS Made Inoperable Due to Anomalies Noted During Testing.Caused by Malfunctioning Speed Control Sys Hydraulic Actuator (EG-R).EG-R Replaced & Rcics Declared Operable on 960405   +