- 05000302/LER-1980-041-03, /03L-0:on 801002,during Normal Operation,Reactor Coolant Tank Isolation Valve WDV-94 Would Not Close Due to Inadequate Torque Switch Setting.Setting Adjusted to Higher Value + (17:47:59, 25 December 2024)
- L-80-357, Forwards Security Plan.Plan Withheld (Ref 10CFR2.790) + (17:48:00, 25 December 2024)
- ML19339A668 + (17:48:02, 25 December 2024)
- ML19339A667 + (17:48:03, 25 December 2024)
- ML19339A666 + (17:48:04, 25 December 2024)
- ML19339A665 + (17:48:05, 25 December 2024)
- ML19339A664 + (17:48:06, 25 December 2024)
- 05000277/LER-1980-021-03, /03L-0:on 800924,ST Revealed That Indication for SV-2671A - G Control Switches Was Lost.Caused by Short in Coil of Dymo Type Solenoid Valve Which Blew Common Fuse in Control Circuit for All Seven Valves.Common Fuse Replaced + (17:48:07, 25 December 2024)
- ML19339A662 + (17:48:08, 25 December 2024)
- ML19339A660 + (17:48:09, 25 December 2024)
- 05000302/LER-1980-041, Forwards LER 80-041/03L-0 + (17:48:10, 25 December 2024)
- 05000336/LER-1980-033-03, /03L-0:on 800930,one of Two Wide Range Neutron Flux Instrumentation (Ni) Channels Failed.Caused by Personnel Lifting Ni Signal Leads to Install Heat Shrink Tubing Over Cable Connector.Leads Reterminated + (17:48:12, 25 December 2024)
- 05000293/LER-1980-072, Forwards LER 80-072/01T-0 + (17:48:14, 25 December 2024)
- ML19339A654 + (17:48:15, 25 December 2024)
- ML19339A653 + (17:48:16, 25 December 2024)
- 05000336/LER-1980-033, Forwards LER 80-033/03L-0 + (17:48:17, 25 December 2024)
- 05000324/LER-1980-079-03, /03L-0:on 801015,review of Containment Atmospheric Dilution Sys in Response to NUREG-0578 Revealed Logic Circuit Relay Which Does Not Meet Single Active Failure Criteria of Sys as Stated in Fsar.Revision Written + (17:48:19, 25 December 2024)
- ML19339A649 + (17:48:27, 25 December 2024)
- ML19339A647 + (17:48:28, 25 December 2024)
- ML19339A645 + (17:48:29, 25 December 2024)
- 05000320/LER-1980-045-03, /03L-0:on 800929,diesel Failed to Start While Performing Surveillance Procedure on Emergency Diesel Generator.Caused by Personnel Error.Control Reset & Operators Reinstructed + (17:48:31, 25 December 2024)
- 05000324/LER-1980-079, Forwards LER 80-079/03L-0 + (17:48:32, 25 December 2024)
- 05000327/LER-1980-150-03, /03L-0:on 800927 During Surveillance in Mode 3, Check Valve Leak Rate Exceeded Tech Spec Limit.Caused by Valve 63-635 Stuck in Open Position Due to Interference Between Disc Nut Lockwire Tack Weld & Valve Body + (17:48:38, 25 December 2024)
- ML19339A640 + (17:48:39, 25 December 2024)
- 05000320/LER-1980-045, Forwards LER 80-045/03L-0 + (17:48:40, 25 December 2024)
- ML19339A637 + (17:48:42, 25 December 2024)
- 05000320/LER-1980-046-01, /01L-0:on 800930,feeder Breadkers for Buses 2-38 & 2-48 Were Removed for Maint & Remained Out of Svc in Excess of Tech Spec Limit.Caused by Failure to Initiate Time Clock.Bus Feeder Breakers Replaced + (17:48:43, 25 December 2024)
- 05000327/LER-1980-150, Forwards LER 80-150/03L-0 + (17:48:45, 25 December 2024)
- ML19339A632 + (17:48:47, 25 December 2024)
- ML19339A631 + (17:48:47, 25 December 2024)
- ML19339A628 + (17:48:48, 25 December 2024)
- 05000320/LER-1980-046, Forwards LER 80-046/01L-0 + (17:48:50, 25 December 2024)
- 05000219/LER-1980-044-03, /03L-0:on 800930,motor Leads in Core Spray Booster Pumps a & C Became Wet When Fire Protection Sys Initiated Inadvertently.Caused by Personnel Error.Pumps Dried, Inspected & Returned to Svc + (17:48:53, 25 December 2024)
- ML19339A623 + (17:48:54, 25 December 2024)
- ML19339A621 + (17:48:55, 25 December 2024)
- ML19339A622 + (17:48:55, 25 December 2024)
- ML19339A620 + (17:48:56, 25 December 2024)
- 05000219/LER-1980-044, Forwards LER 80-044/03L-0 + (17:48:58, 25 December 2024)
- A01204, Forwards Environ Qualification of Safety-Related Electrical Equipment & App 1, Master Listing of Electrical Components by Sys, in Response to NRC 800919 Order for Mod of License & IE Bulletin 79-01B + (17:49:00, 25 December 2024)
- ML19339A613 + (17:49:02, 25 December 2024)
- ML19339A612 + (17:49:06, 25 December 2024)
- ML19339A611 + (17:49:08, 25 December 2024)
- ML19339A610 + (17:49:08, 25 December 2024)
- ML19339A609 + (17:49:09, 25 December 2024)
- ML19339A608 + (17:49:11, 25 December 2024)
- ML19339A607 + (17:49:13, 25 December 2024)
- ML19339A606 + (17:49:14, 25 December 2024)
- ML19339A605 + (17:49:15, 25 December 2024)
- ML19339A604 + (17:49:15, 25 December 2024)
- ML19339A602 + (17:49:16, 25 December 2024)
- ML19339A601 + (17:49:16, 25 December 2024)