Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000368/LER-1980-073, Forwards LER 80-073/03L-0 + (17:19:48, 25 December 2024)
- 05000368/LER-1980-074-03, /03L-0:on 801004,steam Generator Level Indicator 2LI-1031-2 Failed Acceptance Criteria Per Surveillance Test. Caused by Indicating Needle Occasionally Sticking.Needle Adjusted & Calibr Performed + (17:19:51, 25 December 2024)
- 05000368/LER-1980-074, Forwards LER 80-074/03L-0 + (17:19:55, 25 December 2024)
- 05000265/LER-1980-024-03, /03L-0:on 801010,valve MO-2-1-1001-34A Would Only Open Far Enough to Give Dual Position Indication.Caused by Limit Switches on Valve Operator Being Out of Adjustment. Limit Switches Adjusted & Control Switch Cleaned + (17:19:58, 25 December 2024)
- 05000265/LER-1980-024, Forwards LER 80-024/03L-0 + (17:20:01, 25 December 2024)
- 05000339/LER-1980-072-03, /03L-0:on 801008 & 20,boron Injection Tank & Boric Acid Storage Tank Were Sampled & Found to Contain Boron Concentration Below Tech Spec Limit.Caused by Leakage Past Water Shutoff Valve.Valves Readjusted + (17:20:04, 25 December 2024)
- 05000339/LER-1980-072, Forwards LER 80-072/03L-0 + (17:20:06, 25 December 2024)
- AECM-80-265, Requests 60-day Extension So GE May Complete Evaluation of NSSS Portions of Station Affected by IE Bulletin 80-16. Partial Response Submitted on 800827 + (17:20:08, 25 December 2024)
- 05000295/LER-1980-043-03, /03L-0:on 801001,while Testing Charcoal Filter Banks OAVO40 & OAVO41,found Filter Banks 95% Below Required Tech Specs.Caused by Change in Tech Specs.Charcoal Filters Replaced + (17:20:31, 25 December 2024)
- ML19339B910 + (17:20:33, 25 December 2024)
- ML19339B909 + (17:20:34, 25 December 2024)
- ML19339B908 + (17:20:35, 25 December 2024)
- 05000295/LER-1980-043, Forwards LER 80-043/03L-0 + (17:20:37, 25 December 2024)
- ML19339B905 + (17:20:40, 25 December 2024)
- 05000295/LER-1980-044-03, /03L-0:on 801001,during Routine Surveillance,Maint Personnel Found 1C Rx Coolant Flow Channel 1F-424 Comparator Setpoint Low Contrary to Tech Specs.Caused by Instrument Drift.Comparator Recalibr & Returned to Svc + (17:20:42, 25 December 2024)
- 05000254/LER-1980-027-01, /01T-0:on 801015,during IE Bulletin 79-14 Reanalysis of safety-related Piping,Ten Pipes Failed to Meet Operability Criteria.Caused by Improper Const.Pipes Will Be Modified to Meet Requirements Prior to Startup + (17:20:45, 25 December 2024)
- 05000295/LER-1980-044, Forwards LER 80-044/03L-0 + (17:20:47, 25 December 2024)
- 05000254/LER-1980-027, Forwards LER 80-027/01T-0 + (17:20:50, 25 December 2024)
- ML19339B898 + (17:20:51, 25 December 2024)
- ML19339B896 + (17:20:52, 25 December 2024)
- ML19339B897 + (17:20:52, 25 December 2024)
- ML19339B894 + (17:20:53, 25 December 2024)
- IR 05000333/1980013 + (17:20:55, 25 December 2024)
- ML19339B892 + (17:20:56, 25 December 2024)
- ML19339B891 + (17:20:57, 25 December 2024)
- ML19339B889 + (17:20:59, 25 December 2024)
- IR 05000213/1980014 + (17:21:02, 25 December 2024)
- ML19339B886 + (17:21:03, 25 December 2024)
- ML19339B885 + (17:21:07, 25 December 2024)
- ML19339B883 + (17:21:09, 25 December 2024)
- ML19339B881 + (17:21:10, 25 December 2024)
- ML19339B880 + (17:21:11, 25 December 2024)
- ML19339B879 + (17:21:11, 25 December 2024)
- IR 05000443/1980009 + (17:21:19, 25 December 2024)
- ML19339B877 + (17:21:21, 25 December 2024)
- ML19339B875 + (17:21:23, 25 December 2024)
- ML19339B873 + (17:22:04, 25 December 2024)
- IR 05000352/1980014 + (17:22:07, 25 December 2024)
- ML19339B870 + (17:22:08, 25 December 2024)
- ML19339B869 + (17:22:09, 25 December 2024)
- ML19339B867 + (17:22:11, 25 December 2024)
- ML19339B865 + (17:22:18, 25 December 2024)
- ML19339B864 + (17:22:20, 25 December 2024)
- ML19339B863 + (17:22:21, 25 December 2024)
- IR 05000199/1980001 + (17:22:23, 25 December 2024)
- ML19339B861 + (17:22:25, 25 December 2024)
- ML19339B859 + (17:22:26, 25 December 2024)
- ML19339B857 + (17:22:29, 25 December 2024)
- IR 05000289/1980007 + (17:22:32, 25 December 2024)
- ML19339B855 + (17:22:34, 25 December 2024)
- IR 05000289/1980020 + (17:22:38, 25 December 2024)