- 05000213/LER-1976-003-03, /03L-0:on 760202,Channel 33 Overpower Trip Setpoint Exceeded Limit.Caused by Normal Instrument Drift. Setpoint Reset to Allow for Drift W/O Exceeding Limit + (17:15:53, 24 December 2024)
- 05000213/LER-1976-001-01, /01T-0:on 760122,steam Flow Transmitter Sensing Lines Froze,Simulating High Steam Flow Trip Signals in Reactor Protection Sys & Tripping Reactor.Caused by sub-zero Weather & Openings Inadvertently Left in Wall + (17:15:55, 24 December 2024)
- ML19343C285 + (17:15:56, 24 December 2024)
- 05000213/LER-1976-005-03, /03L-0:on 760124,1A Centrifugal Charging Pump Outboard Seal Leaked Excessively.Caused by O-ring Failure. Seal Replaced + (17:15:58, 24 December 2024)
- 05000213/LER-1976-007-03, /03L-0:on 760219,nuclear Instrumentation Channel 34 Overpower Trip Setpoint Exceeded Limits.Caused by Normal Instrument Drift.Setpoint Adjusted to Allow for Some Drift W/O Exceeding Limit + (17:16:00, 24 December 2024)
- 05000213/LER-1976-008-03, /03L-0:on 760330,rupture Disk PSE-1172B Ruptured, Causing Waste Gas Decay Tank TK-60B Pressure to Drop.Cause Under Investigation by Vendor.Disk Removed for Insp & Sys Design to Be Reviewed + (17:16:02, 24 December 2024)
- ML19343C281 + (17:16:03, 24 December 2024)
- 05000213/LER-1976-014, /01T-0:on 760626,power to Residual Heat Removal Pump Interrupted for 30-s.Caused by Automatic Circuit Breaker Trip on Station Svc Transformer Due to Spurious 115 Kv Fault Signal.Backup Sensing Circuits to Be Changed + (17:16:06, 24 December 2024)
- ML19343C277 + (17:16:07, 24 December 2024)
- 05000213/LER-1976-015-03, /03L-0:on 760629,abnormal Pressure Noted on Waste Gas Decay Tank TK-6013.Caused by Rupture Disk Rupture at 52 Psig,Rather than 225 Psig.Rupture Disk Replaced & Plant Design Change Prepared to Relocate Rupture Disk + (17:16:09, 24 December 2024)
- 05000213/LER-1976-017-03, /03L-0:on 760720,loop 2 Steam Line Flow Indicator Failed Low,Annunciating on Main Control Board.Caused by Leaking Sensing Line cross-threaded Fitting on High Side of Loop 2 Pressure Transmitter.Damage Fitting Replaced + (17:16:11, 24 December 2024)
- ML19343C274 + (17:16:12, 24 December 2024)
- ML19343C272 + (17:16:13, 24 December 2024)
- ML19343C271 + (17:16:14, 24 December 2024)
- ML19343C270 + (17:16:15, 24 December 2024)
- 05000213/LER-1976-018-01, /01T-0:on 760820,Westinghouse Informed Util of Error Found in ECCS Analysis.Cause Noted in Encl + (17:16:17, 24 December 2024)
- 05000213/LER-1976-019-03, /03L-0:on 761001,concentrated Boric Acid Pump 1A (Canned Motor) Developed Leak in Can.Caused by Wiped Pump Bearings Allowing Rotor to Drop & Wear Hole Through Can.Pump Replaced W/Spare & Rebuilt + (17:16:19, 24 December 2024)
- 05000213/LER-1976-016-03, /03l-2:on 760705,auxiliary Feed Pump Failed to Develop Proper Discharge Pressure for Startup.Caused by Back Leakage from Steam Generator 3 Through Check Valve in Feed Line.Faulty Check Valve Removed,Cleaned & Repaired + (17:16:21, 24 December 2024)
- 05000213/LER-1976-004-04, /04L-1:on 760202,Jan 1976 Monthly Impingement Loss for Spottail Shiners Exceeded ETS Limits.No Corrective Action Taken + (17:16:23, 24 December 2024)
- 05000213/LER-1977-001-03, /03L-0:on 761214,small Leak Found at Juncture of Waste Liquid/Steam Generator Blowdown Line & Svc Water Effluent Line.Caused by Pipe Matl Deterioration from Steam Generator Blowdown Stream & Cold Svc Water Interaction + (17:16:26, 24 December 2024)
- 05000213/LER-1977-002-03, /03L-0:on 770224,leak Found at Recycle Test Tank a Manway.Caused by Corroded Aluminum Bolts & Nuts. Temporary Clamps Applied to Stop Leakage.Aluminum Nuts & Bolts Replaced W/Stainless Steel + (17:16:28, 24 December 2024)
- ML19343C260 + (17:16:29, 24 December 2024)
- 05000213/LER-1977-005-03, /03L-0:on 770404,decrease in Charging Pump Discharge Pressure & Increase in Motor Amperage Noted.Caused by Pump Shaft Circumferential Cracks Under Pressure Reducing Sleeve.Shaft & Pump Wear Rings Replaced + (17:16:31, 24 December 2024)
- 05000213/LER-1977-006-03, /03L-0:on 770426,while Filling & Venting Charging Pump 1A,small Weep Noted on Suction End Mechanical Seal Housing 1A.Caused by Small Leak Path Opened Through Slight Porosity During Decontamination of Housing.Housing Replaced + (17:16:33, 24 December 2024)
- 05000213/LER-1977-007-03, /03L-0:on 770428,inboard Motor Bearing Temp Increase Caused Charging Pump 1A to Be Shut Down.Caused by Excessive Thrust on Motor Bearing Thrust Plate Due to Axial Misalignment Between Pump & Motor.Bearings Replaced + (17:16:34, 24 December 2024)
- ML19343C256 + (17:16:35, 24 December 2024)
- 05000213/LER-1977-008-03, /03L-0:on 770523,containment Air Recirculation Fan 2 Vibration Exceeded Alarm Setpoints.Caused by Normal Wear. Bearing Replaced + (17:16:37, 24 December 2024)
- 05000213/LER-1977-009-03, /03L-0:on 770531,overhead Crane Control Malfunctioned,Lifting Spent Fuel Racks Approx 12 & 6 Inches. Caused by Button Stuck in Depressed Position Due to Mechanical Wear of Button Internal Mechanism.Button Replaced + (17:16:39, 24 December 2024)
- GO2-19-162, Amendment 65 to Final Safety Analysis Report, Chapter 12, Radiation Protection + (17:16:41, 24 December 2024)
- ML19343C252 + (17:16:43, 24 December 2024)
- ML19343C251 + (17:16:44, 24 December 2024)
- ML19343C250 + (17:16:45, 24 December 2024)
- ML19343C249 + (17:16:46, 24 December 2024)
- ML19343C248 + (17:16:47, 24 December 2024)
- ML19343C247 + (17:16:47, 24 December 2024)
- ML19343C246 + (17:16:48, 24 December 2024)
- ML19343C245 + (17:16:49, 24 December 2024)
- 05000213/LER-1978-001-01, /01T-0:on 780126,Marathon Terminal Blocks Failed in twenty-second Hour of Scheduled 24-h Screening Type Test to Show Ability to Function in Postulated Containment Environ After Loca.Caused by Current Path + (17:16:51, 24 December 2024)
- ML19343C242 + (17:16:52, 24 December 2024)
- ML19343C241 + (17:16:53, 24 December 2024)
- ML19343C240 + (17:16:54, 24 December 2024)