- 05000298/LER-1980-027, Forwards LER 80-027/03L-0 + (16:12:25, 24 December 2024)
- 05000029/LER-1980-015, Forwards LER 80-015/03L-0 + (16:12:29, 24 December 2024)
- 05000321/LER-1980-090, Forwards LER 80-090/03L-0 + (16:12:30, 24 December 2024)
- 05000368/LER-1980-047-03, /03L-0:on 800703,during Mode 1 Operation,While Making Routine Check of Radiation Monitoring Sys,Containment Atmosphere Radiation Monitor Found Inoperable.Caused by Overload Trip Due to High Room Temp + (16:12:32, 24 December 2024)
- ML19344E037 + (16:12:34, 24 December 2024)
- 05000317/LER-1980-036-03, /03L-0:on 800721,after Performing Preventative Maint,Discovered That Diesel Generator 11 Had No Speed or Voltage Control.Caused by Water Dripping on Generator Voltage Transformer & Regulator from Jacket Cooling Sys + (16:12:35, 24 December 2024)
- 05000321/LER-1980-088-03, /03L-0:on 800725,w/reactor in start-up Mode & Reactor Pressure at 150 1b & 0% Power,During HPCI Overspeed Trip Test,Turbine Failed to Trip at or Below 5,000 Revolutions Per Minute.Caused by Setpoint Drift + (16:12:37, 24 December 2024)
- ML19344E034 + (16:12:38, 24 December 2024)
- ML19344E032 + (16:12:39, 24 December 2024)
- ML19344E033 + (16:12:39, 24 December 2024)
- 05000298/LER-1980-026-03, /03L-0:on 800701,during Routine Measurement of Identified Reactor Leakage,Drywell Equipment Drain Sump Flow Instrument Found Inoperable.Caused by Broken Slide Wire in Recorder & Blown Fuse in Power Supply.Fuse & Wire Replace + (16:12:41, 24 December 2024)
- 05000321/LER-1980-088, Forwards LER 80-088/03L-0 + (16:12:42, 24 December 2024)
- 05000302/LER-1980-030-03, /03L-0:on 800731,during Monthly Diesel Generator Surveillance,Emergency Diesel Generator B Tripped as Result of Separation of Turbocharger Discharge Ductwork Due to Sheared Bolts on Mounting Bracket.Caused by Vibration + (16:12:44, 24 December 2024)
- ML19344E026 + (16:12:46, 24 December 2024)
- 05000298/LER-1980-026, Forwards LER 80-026/03L-0 + (16:12:47, 24 December 2024)
- ML19344E022 + (16:12:48, 24 December 2024)
- 05000302/LER-1980-030, Forwards LER 80-030/03L-0 + (16:12:49, 24 December 2024)
- ML19344E019 + (16:12:50, 24 December 2024)
- ML19344E018 + (16:12:51, 24 December 2024)
- 05000321/LER-1980-089-03, /03L-0:on 800726,during Normal Operation,Drywell & Torus Temp Recorder lT47-R611 Found Inoperative.Caused by Stripped Gear in Print Drive Mechanism.Gear Replaced.Design Change Initiated to Replace Recorder + (16:12:52, 24 December 2024)
- 05000366/LER-1980-121-01, /01T-0:on 800813,w/unit at 2412 MW While Performing HNP-2-3102,pressure Switches Actuated Out of Tolerance.Caused by Setpoint Drift.Switches Recalibr. HNP-2-3102 Performed Satisfactorily + (16:12:55, 24 December 2024)
- 05000317/LER-1980-036, Forwards LER 80-036/03L-0 + (16:12:57, 24 December 2024)
- 05000321/LER-1980-089, Forwards LER 80-089/03L-0 + (16:12:58, 24 December 2024)
- ML19344E011 + (16:13:00, 24 December 2024)
- 05000338/LER-1980-063-01, /01T-0:on 800808,w/unit at 100% Power,Feedwater Flow Signal to Reactor Trip Sys Determined to Be in Error by Approx 4%.Caused by Venturi Fouling in Lines.Fouling Will Be Monitored by Comparing Feed Flow to Steam Flow + (16:13:02, 24 December 2024)
- 05000312/LER-1980-036-41, /041-0:on 800710,review of Jul 1980 Effluent Monitoring Charts Indicated Plant Liquid Effluent Ph in Excess of 8.5 Tech Spec Limit.Cause Unknown.Automatic Diversion Setpoint Lowered to Minimize Recurrence + (16:13:05, 24 December 2024)
- 05000312/LER-1980-036, Forwards LER 80-036/041-0 + (16:13:07, 24 December 2024)
- 05000338/LER-1980-063, Forwards LER 80-063/01T-0 + (16:13:09, 24 December 2024)
- 05000312/LER-1980-038-41, /041-0:on 800729,review of Plant Effluent Data for Jul 1980 Indicated That on 800629 & 30,sample Indicated 0.25 & 0.3 Mg/Liter Chlorine.Second Followup Sample Not Obtained.Caused by Personnel Error.Personnel Reinstructed + (16:13:11, 24 December 2024)
- ML19344E001 + (16:13:12, 24 December 2024)
- ML19344E000 + (16:13:13, 24 December 2024)
- ML19344D999 + (16:13:13, 24 December 2024)
- 05000312/LER-1980-038, Forwards LER 80-038/041-0 + (16:13:15, 24 December 2024)
- 05000267/LER-1980-042-03, /03L-0:on 800725,plant Was Operated at Approx 47% Thermal Power & 131 Mwe W/Two Inoperable Reserve Shutdown Units in 30 Hopper Subsystem.Caused by Isolation of Bottle for Repair of Leakage at Brass Fitting for Region 15 Hook + (16:13:17, 24 December 2024)
- 05000293/LER-1980-040-03, /03L-0:on 800724,standby Gas Treatment Sys Found Inoperable.Caused by Breaker Being Unintentionally Moved to Open Position,Possibly During Daily Operator Tour.Breaker Returned to Normal.Operational Check Satisfactory + (16:13:18, 24 December 2024)
- ML19344D994 + (16:13:19, 24 December 2024)
- ML19344D993 + (16:13:20, 24 December 2024)
- ML19344D992 + (16:13:21, 24 December 2024)
- 05000293/LER-1980-040, Forwards LER 80-040/03L-0 + (16:13:22, 24 December 2024)
- ML19344D989 + (16:13:23, 24 December 2024)
- 05000267/LER-1980-039-03, /03L-0:on 800721,liquid Nitrogen Storage Tank Level Determined Below Tech Specs.Caused by Use of Nitrogen Blanket During Loop Shutdown & Late Delivery of Liquid Nitrogen Shipment.More Liquid Nitrogen Ordered + (16:13:25, 24 December 2024)
- ML19344D987 + (16:13:26, 24 December 2024)
- 05000344/LER-1980-016-03, /03L-0:on 800719,during Low Power Physics Testing, South Boric Acid Tank Boron Concentration & North Boric Acid Tank Level Exceeded Tech Specs.Caused by Personnel Error + (16:13:30, 24 December 2024)
- 05000344/LER-1980-016, Forwards LER 80-016/03L-0 + (16:13:33, 24 December 2024)
- ML19344D981 + (16:13:34, 24 December 2024)
- ML19344D980 + (16:13:34, 24 December 2024)
- ML19344D979 + (16:13:35, 24 December 2024)
- ML19344D978 + (16:13:38, 24 December 2024)
- 05000366/LER-1980-114-03, /03L-0:on 800726,while Taking Unit to Cold Shutdown,Hpci Sys Failed to Isolate at Greater than or Equal to 100 Psig.Caused by Corrosion of B Isolation Logic Pressure Switch 2E41-N001D.Instrument Replaced + (16:13:39, 24 December 2024)
- ML19344D976 + (16:13:40, 24 December 2024)
- 05000366/LER-1980-114, Forwards LER 80-114/03L-0 + (16:13:42, 24 December 2024)