Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000293/LER-1981-031-03, /03L-0:on 810618 & 19,main Stack Sample Pump a Tripped.Caused by Increased Internal Friction + (13:30:12, 21 December 2024)
- 05000293/LER-1981-031, Forwards LER 81-031/03L-0 + (13:30:14, 21 December 2024)
- 05000293/LER-1981-029-03, /03L-0:on 810617 & 18,RBV Sample Pump a Tripped. Caused by Internal Pump Friction Due to Normal Wear.Pumps Rebuilt & Spare Pump Installed + (13:30:15, 21 December 2024)
- ML20009E797 + (13:30:16, 21 December 2024)
- 05000293/LER-1981-029, Forwards LER 81-029/03L-0 + (13:30:18, 21 December 2024)
- ML20009E794 + (13:30:19, 21 December 2024)
- ML20009E792 + (13:30:19, 21 December 2024)
- 05000293/LER-1981-032-03, /03L-0:on 810619,reactor Coolant Leak Detection Air Sampling Sys C-19 Declared Inoperable.Caused by Valves Sticking in Closed Position Due to Dirt in Sys Check Valves. Valves Disassembled & Cleaned + (13:30:21, 21 December 2024)
- 05000293/LER-1981-032, Forwards LER 81-032/03L-0 + (13:30:22, 21 December 2024)
- ML20009E788 + (13:30:24, 21 December 2024)
- ML20009E787 + (13:30:25, 21 December 2024)
- ML20009E786 + (13:30:26, 21 December 2024)
- ML20009E785 + (13:30:27, 21 December 2024)
- ML20009E782 + (13:30:28, 21 December 2024)
- ML20009E783 + (13:30:28, 21 December 2024)
- IR 05000334/1981017 + (13:30:29, 21 December 2024)
- ML20009E775 + (13:30:31, 21 December 2024)
- ML20009E777 + (13:30:31, 21 December 2024)
- ML20009E773 + (13:30:32, 21 December 2024)
- IR 05000461/1981017 + (13:30:33, 21 December 2024)
- ML20009E771 + (13:30:35, 21 December 2024)
- ML20009E769 + (13:30:36, 21 December 2024)
- 05000366/LER-1981-064-03, /03L-0:on 810626,while Performing Diesel Generator Manual Start Surveillance Procedure on 2P43-5001A Generator, Speed Adjust Switch Found Inoperable.Caused by Synchronizing Motor.Motor Disassembled,Cleaned & Returned to Svc + (13:30:37, 21 December 2024)
- ML20009E766 + (13:30:39, 21 December 2024)
- ML20009E765 + (13:30:40, 21 December 2024)
- ML20009E764 + (13:30:41, 21 December 2024)
- ML20009E759 + (13:30:42, 21 December 2024)
- 05000366/LER-1981-064, Forwards LER 81-064/03L-0 + (13:30:43, 21 December 2024)
- ML20009E755 + (13:30:44, 21 December 2024)
- ML20009E752 + (13:30:45, 21 December 2024)
- ML20009E751 + (13:30:46, 21 December 2024)
- ML20009E750 + (13:30:47, 21 December 2024)
- ML20009E749 + (13:30:47, 21 December 2024)
- ML20009E748 + (13:30:48, 21 December 2024)
- IR 05000454/1981007 + (13:30:49, 21 December 2024)
- ML20009E746 + (13:30:50, 21 December 2024)
- ML20009E744 + (13:30:51, 21 December 2024)
- 05000321/LER-1981-060-03, /03L-0:on 810624,during steady-state Operation, 1D11-K619B,reactor Bldg Stack Monitor B Found Inoperative. Caused by Component Failure.Component Replaced & Monitor Recalib.Instrument Returned to Svc + (13:30:53, 21 December 2024)
- ML20009E740 + (13:30:55, 21 December 2024)
- ML20009E739 + (13:30:56, 21 December 2024)
- 05000321/LER-1981-060, Forwards LER 81-060/03L-0 + (13:31:00, 21 December 2024)
- ML20009E735 + (13:31:01, 21 December 2024)
- ML20009E734 + (13:31:02, 21 December 2024)
- IR 05000483/1981012 + (13:31:04, 21 December 2024)
- ML20009E732 + (13:31:05, 21 December 2024)
- ML20009E729 + (13:31:07, 21 December 2024)
- ML20009E728 + (13:31:07, 21 December 2024)
- ML20009E727 + (13:31:08, 21 December 2024)
- IR 05000438/1981012 + (13:31:09, 21 December 2024)
- ML20009E723 + (13:31:11, 21 December 2024)
- 05000369/LER-1981-101-03, /03L-0:on 810617,10 Batch Releases of Used Powdex Resin Were Transferred to Chemical Treatment Ponds W/O Making Estimates of Sr-89 & Sr-90 Per Previous Monthly Analysis.Caused by Health Physics Group Error.Mod Requested + (13:31:12, 21 December 2024)