Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000296/LER-1981-054-03, /03L-0:on 810930,while Performing Special Instructions 4.2.F-10,pressure Switch PS-64-67 Found to Operate at 0.14 Psig Above Limit.Caused by Instrument Drift. Switch Recalibr & Returned to Svc + (16:59:43, 20 December 2024)
- ML20032B576 + (16:59:44, 20 December 2024)
- ML20032B575 + (16:59:48, 20 December 2024)
- 05000369/LER-1981-009, Forwards LER 81-009/03L-0.Detailed Event Analysis Encl + (16:59:49, 20 December 2024)
- ML20032B571 + (16:59:51, 20 December 2024)
- 05000296/LER-1981-054, Forwards LER 81-054/03L-0 + (16:59:52, 20 December 2024)
- IR 05000277/1981022 + (16:59:54, 20 December 2024)
- 05000366/LER-1981-097-03, /03L-0:on 810930,during Steady State Power,Water Discovered Leaking from Penetration in Condensate Transfer Pumps Encl Wall Onto Ground.Caused by Pump Seal Failure & Open Penetration in Wall.Seal Repaired & Dirt Removed + (16:59:56, 20 December 2024)
- IR 05000324/1981018 + (17:00:01, 20 December 2024)
- ML20032B565 + (17:00:03, 20 December 2024)
- ML20032B564 + (17:00:04, 20 December 2024)
- 05000296/LER-1981-056-03, /03L-0:on 811003,after Lubrication of 3EA Rmov Motor Generator Set Generator,Set Removed from Svc Due to Increased Vibration & Noise.Caused by Low Lubrication Level. Generator Side of Flywheel Bearing Replaced + (17:00:06, 20 December 2024)
- 05000369/LER-1981-013-03, /03L-0:on 810212,radiation Detectors EMF 33,35,36, 37,38,39 & 40 Were Declared Inoperable Due to Loss of Sample Flows.Caused by Individual Nonrelated Failures of Each Emf. Repairs Performed & EMFs Declared Operable + (17:00:08, 20 December 2024)
- ML20032B560 + (17:00:09, 20 December 2024)
- 05000366/LER-1981-097, Forwards LER 81-097/03L-0.Detailed Event Analysis Encl + (17:00:11, 20 December 2024)
- ML20032B556 + (17:00:13, 20 December 2024)
- ML20032B554 + (17:00:14, 20 December 2024)
- ML20032B552 + (17:00:15, 20 December 2024)
- 05000296/LER-1981-053-03, /03L-0:on 810929,during Normal Operation,Torus Water Level Transmitter 3-LT-64-66 Was Indicating 6.5% Lower than Allowed by Tech Specs.Caused by Instrument Drift. Transmitter Recalibr + (17:00:17, 20 December 2024)
- 05000366/LER-1981-092-03, /03L-0:on 811006,rod Out Permission Light Was Lost & Control Rods Could Not Be Withdrawn.Caused by Failure of Contacts on 2C11-K1 & K2 in Relay Module 2.Relays Replaced & Relay Block Monitor B Returned to Svc + (17:00:19, 20 December 2024)
- IR 05000369/1981029 + (17:00:20, 20 December 2024)
- 05000366/LER-1981-002-03, /03L-0:on 810106,reactor Core Isolation Cooling Steamline Pressure Switches 2E51-NO19A & C Were Found to Actuate Below Tech Spec Limits.Caused by Setpoint Drift. Switches Recalibr + (17:00:22, 20 December 2024)
- 05000296/LER-1981-053, Forwards LER 81-053/03L-0 + (17:00:24, 20 December 2024)
- IR 05000416/1981031 + (17:00:26, 20 December 2024)
- ML20032B543 + (17:00:28, 20 December 2024)
- 05000366/LER-1981-092, Forwards LER 81-092/03L-0 + (17:00:29, 20 December 2024)
- IR 05000309/1981023 + (17:00:31, 20 December 2024)
- 05000296/LER-1981-056, Forwards LER 81-056/03L-0 + (17:00:33, 20 December 2024)
- 05000366/LER-1981-002, Forwards LER 81-002/03L-0 + (17:00:35, 20 December 2024)
- 05000369/LER-1981-013, Forwards LER 81-013/03L-0.Detailed Event Analysis Encl + (17:00:37, 20 December 2024)
- ML20032B533 + (17:00:38, 20 December 2024)
- 05000325/LER-1981-069-03, /03L-0:on 810930,primary Containment Atmosperic Monitor 1-CAC-ATH-1259 Tripped.Caused by Frozen Condensate in Condenser Coils of Monitor Analyzer Air Dryer Due to Misadjusted Hotgas Bypass Valve.Valve Adjusted + (17:00:41, 20 December 2024)
- 05000321/LER-1981-113-03, /03L-0:on 811008,while Performing High Pressure Instrumentation Surveillance,Pressure Switch 1B21-N023B Found Actuating in Excess of Tech Spec Limits.Caused by Setpoint Drift.Instrument Recalibr & Returned to Svc + (17:00:43, 20 December 2024)
- 05000327/LER-1981-015-03, /03L-0:on 810216,during Surveillance Testing,Ice Condenser Basket Bays 1,18 & 24 Were Found Below Limits for Average Basket Weight.Caused by Sublimation.Ice Added Throughout Ice Condenser + (17:00:45, 20 December 2024)
- ML20032B528 + (17:00:46, 20 December 2024)
- ML20032B526 + (17:00:48, 20 December 2024)
- 05000280/LER-1981-059-03, /03L-0:on 811005,w/reactor Coolant at Approx 200 F & Heating up,TV-CC-109A (Component Cooling to RHR) Isolation Valve Would Not Close.Cause Undetermined.Air Line Disconnected & Observed to Blow Clear.Air Line Reconnected + (17:00:49, 20 December 2024)
- 05000325/LER-1981-069, Forwards LER 81-069/03L-0 + (17:00:51, 20 December 2024)
- AECM-81-378, Responds to NRC Re Violations Noted in IE Insp Repts 50-416/81-31 & 50-417/81-13.Corrective Actions:Lesson Plans Revised to Familiarize Students W/Methods of Decontamination of Personnel & Equipment + (17:00:53, 20 December 2024)
- ML20032B521 + (17:00:55, 20 December 2024)
- 05000321/LER-1981-113, Forwards LER 81-113/03L-0 + (17:00:57, 20 December 2024)
- 05000335/LER-1981-045-03, /03L-0:on 810930,reactor Protection Sys loss-of- Load Pressure Switch Points Found 50 Psi Below Limit.Caused by Setpoint Drift.Switches Recalibr to 800 Psig.Procedure Changed to Calibr Switches at 1,000 Psig + (17:00:59, 20 December 2024)
- 05000327/LER-1981-015, Forwards LER 81-015/03L-0 + (17:01:04, 20 December 2024)
- 05000270/LER-1981-003-03, /03L-0:on 810302,alarm Sounded to Indicate High Temp on Reactor Bldg Cooling Unit.Caused by Grease Starvation.Reactor Bldg Cooling Unit 2C Was Secured & Grease Added to Motor Bearings.Cooling Unit Restarted + (17:01:06, 20 December 2024)
- ML20032B513 + (17:01:11, 20 December 2024)
- 05000335/LER-1981-045, Forwards LER 81-045/03L-0 + (17:01:12, 20 December 2024)
- 05000327/LER-1981-025-03, /03L-0:on 810217,during Surveillance Instruction SI-7,diesel Generator 1B-B Failed to Load Properly.Caused by Blown Fuse in Governor Potentiometer Circuit.Fuse Replaced + (17:01:15, 20 December 2024)
- ML20032B508 + (17:01:16, 20 December 2024)
- 05000270/LER-1981-003, Forwards LER 81-003/03L-0.Detailed Event Analysis Encl + (17:01:18, 20 December 2024)
- 05000325/LER-1981-062-03, /03L-0:on 811002,during Butterfly Valve Actuation Test,Butterfly Valve 1-CAC-V17 Opened at Simulated Pressure Differential of 0.35 Psid.On 811017 Butterfly Valve 1-CAC-V16 Opened at 0.37 Psid.Caused by Instrument Drift + (17:01:20, 20 December 2024)
- ML20032B503 + (17:01:21, 20 December 2024)