Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000266/LER-1982-002, Forwards LER 82-002/03L-0 + (01:58:41, 20 December 2024)
- 05000272/LER-1982-003-03, /03L-0:on 820106,1B & 1C Diesels Locked Out, Rendering Diesels Inoperable at Same Time.On 820106,diesel Generator 1C Declared Inoperable While Diesel 1B Out of Svc for Maint.Caused by Misinterpretation of Lockout Switch Tag + (01:58:42, 20 December 2024)
- 05000364/LER-1981-055-03, /03L-0:on 811208,2B Recombiner Oxygen Inlet Analyzer Declared Inoperable.Caused by Faulty Analyzer Cell. Cell Replaced & Analyzer Recalibr + (01:58:47, 20 December 2024)
- ML20040G568 + (01:58:48, 20 December 2024)
- 05000259/LER-1982-002, Forwards LER 82-002/03L-0 + (01:58:50, 20 December 2024)
- ML20040G565 + (01:58:51, 20 December 2024)
- 05000259/LER-1982-001-03, /03L-0:on 820103,meteorological Instrumentation O-Tdr-90-103 Air Temp Delta T & O-XR-90-102-1 (30 Ft Air Speed) Failed.Caused by Lightning Damage to Transistors Q3 & Q4 & Blown Fuses in Panel 9-34 & at Meterological Station + (01:58:52, 20 December 2024)
- 05000364/LER-1981-053-03, /03L-0:on 811210,diesel Generator 2C Failed to Start.Caused by Personnel Closing Air Start Header Isolation Valves Instead of Air Header Cross Connect Valves.Valves Realigned + (01:58:54, 20 December 2024)
- 05000336/LER-1982-003-03, /03L-0:on 820104,fan F394 Tripped on Overload, Rendering Radiation Monitors 8123A & B Inoperable.Caused by Seized Bearings Due to Lack of Lubricaton.Blower Replaced. Proper Drainplug Installation Will Be Verified + (01:58:55, 20 December 2024)
- 05000336/LER-1982-003, Forwards LER 82-003/03L-0 + (01:59:03, 20 December 2024)
- ML20040G556 + (01:59:04, 20 December 2024)
- ML20040G555 + (01:59:05, 20 December 2024)
- 05000339/LER-1982-004-03, /03L-0:on 820110,containment Isolation Steam Operator Blowdown Valve TV-BD-200C Would Not Remain Closed from Control Room.Caused by Excessive Moisture in Limit Switch Housing.Housing Drained + (01:59:06, 20 December 2024)
- 05000259/LER-1981-094-03, /03L-0:on 811226,B Dihydrogen Dioxide Sample Return Pump Tripped & Would Not Reset.Caused by Locked Cam Bearing Due to Misalignment or Insufficient Lubrication. Cams & Cam Bearings Replaced + (01:59:08, 20 December 2024)
- 05000259/LER-1982-001, Forwards LER 82-001/03L-0 + (01:59:10, 20 December 2024)
- 05000272/LER-1982-004-03, /03L-0:on 820109,primary Coolant Water Sample Results Indicated Excessive Boron Concentration,Constituting Positive Reactivity Change.Caused by Water Draining Out of Steam Generator Tubes.Rcs Rapid Boration Initiated + (01:59:12, 20 December 2024)
- 05000280/LER-1982-001-03, /03L-0:on 820106,spurious Safety Injection Caused Phase 1 Containment Isolation.Trip Valve TV-CC-109B Failed to Close.Caused by Teflon Tape Preventing Operation of 3-way SOV That Controls TV-CC-109B + (01:59:14, 20 December 2024)
- ML20040G548 + (01:59:15, 20 December 2024)
- ML20040G547 + (01:59:16, 20 December 2024)
- 05000324/LER-1982-005-01, /01T-0:on 820116,both RHR Svc Water Loops Inoperable,Rendering RHR Shutdown & Suppression Pool Cooling Modes Inoperable.Caused by Loop Pumps Failure Due to Plugging of Sensing Line to Suction Header Pressure Switch + (01:59:17, 20 December 2024)
- 05000339/LER-1982-004, Forwards LER 82-004/03L-0 + (01:59:22, 20 December 2024)
- 05000280/LER-1982-001, Forwards LER 82-001/03L-0 + (01:59:23, 20 December 2024)
- 05000259/LER-1981-094, Forwards LER 81-094/03L-0 + (01:59:25, 20 December 2024)
- ML20040G537 + (01:59:28, 20 December 2024)
- ML20040G536 + (01:59:28, 20 December 2024)
- 05000324/LER-1982-005, Forwards LER 82-005/01T-0 + (01:59:29, 20 December 2024)
- ML20040G531 + (01:59:33, 20 December 2024)
- ML20040G532 + (01:59:33, 20 December 2024)
- ML20040G530 + (01:59:35, 20 December 2024)
- ML20040G528 + (01:59:35, 20 December 2024)
- ML20040G526 + (01:59:36, 20 December 2024)
- ML20040G521 + (01:59:41, 20 December 2024)
- ML20040G522 + (01:59:41, 20 December 2024)
- ML20040G519 + (01:59:42, 20 December 2024)
- ML20040G518 + (01:59:42, 20 December 2024)
- ML20040G517 + (01:59:43, 20 December 2024)
- ML20040G516 + (01:59:44, 20 December 2024)
- ML20040G515 + (01:59:45, 20 December 2024)
- ML20040G513 + (01:59:47, 20 December 2024)
- ML20040G512 + (01:59:48, 20 December 2024)
- ML20040G510 + (01:59:49, 20 December 2024)
- ML20040G508 + (01:59:51, 20 December 2024)
- ML20040G507 + (01:59:52, 20 December 2024)
- ML20040G506 + (01:59:54, 20 December 2024)
- ML20040G504 + (01:59:55, 20 December 2024)
- ML20040G501 + (01:59:56, 20 December 2024)
- ML20040G497 + (01:59:57, 20 December 2024)
- ML20040G484 + (01:59:58, 20 December 2024)
- ML20040G483 + (01:59:59, 20 December 2024)
- ML20040G481 + (02:00:00, 20 December 2024)
- ML20040G480 + (02:00:01, 20 December 2024)