f Enclosura to S rial:RSEP/82-186 I
Pags 1 of 3 OPERATING DATA REPORT DOCKET NO: 50-261 DATE: 820201 l.
COMPLETED BY: H. Ray-Norris TELEP110NE: (803) 383-4524 OPERATING STATUS Notes:
- 1. Unit Name:
H. B. Robinson Unit Two There are presently 113 spent-
- 2. Reporting Period: 820101,0000/820131,2400 fuel assemblies in the spent-
- 3. Licensed Thermal Power (MWt): 2300 fuel pool.
- 4. Nameplate Rating (Gross We): 739
- 5. Design Electrical Rating (Net MWe): 700
- 6. Maximum Dependable Capacity (Gross'MWe): 700
- 7. Maximum Dependable Capacity (Net MWe):
665
- 8. If Changes Occur in Capacity Ratings (Item Number 3 through 7) Since Last Report, Give Reasons:
No change.
- 9. Power Level to Which Restricted, If Any (Net MWe): N535 (80% reactor power)
- 10. Reasons for Restrictions, If Any: Although the unit is not restricted by any outside agency, the power level is presently reduced due to steam generator considerations.
This Month Yr.-to-Date Cumulative.
- 11. Ilours in Reporting Period 744 744 95670
- 12. Number of Hours Reactor Was Critical 744 744 73089.42
- 13. Reactor Reserve Shutdown Hours 0
0 1085.30
- 14. Hours Generator On-Line 744 744 71299.31
- 15. Unit Reserve Shutdown Hours 0
0 23.20
- 16. Gross Thermal Energy Generated (MWH) 1361248 1361248_
144456622
- 17. Gross Electrical Energy Generated (MWil) 436215 436215 46512185
- 18. Net Electrical Energy Generated (MW11) 411076 411076 44031327
- 19. Unit Service Factor 100
- 100 74.52 l
- 20. Unit Availability Factor 100 100 7M
- 21. Unit Capacity Factor (Using MD': Net) 83.08 83.08 69.21
- 22. Unit Capacity Factor (Using DER Net) 78.93 78.93 65.74
- 23. Unit Forced Outage Rate 0
0 14.46
- 24. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each):
Refuelinn/ Maintenance Outane in Late Wintor, fourteen weeks.
- 25. If Shut Down At End of Report Period, Estimated Date of Startup On Line.
- 26. Units In Test Status (Prior to Commercial Operation):
Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION 8202160222 820208 PDR ADOCK 05000261 R
PDR (9/77) l.
18
< eg ;
r
..ww.
we u
~
nx rnaumgy
AVERAGE D.gity UNIT POWER LEVEL-Paga.2 of 3 l
DOCKET NO, 50-261 Tw UNIT
/
DATE 820201
/
/
CO\\1PLElED llY 11. Ray Norris TELEPilONE (803)383-4524 SiONill
.Tanua rv' DAY AVERAG$ DAILY POWER LEVEL DAY AVER AGE D.\\lLY POWER LEVEL (31We Net) 131We Ncs; 562 568 g
37 2
561 18 57a 3
559 19 523 557 4
20 305 556 5
21 479 562 565 6
22 7
565 565 23 566 g
24 565 565 566 25 10 565 26 566 566 567 33 27 566 12 28 567 568-567 13 29 565 I4 30 567 567 33 3g 16 569 s
.)
INSTRUCTIONS On this format list the average daily unit power leselin htwe.Nei rin eJegi day in slic reportmg month Compute to the nearest uhule enegaware, (9/77) 5 4
9 fi
,7
[f
.;gg,'
.~
- 4,, y'**,,,, y _z,,g,yy t - -# ' '. fkh4
,,g4 j g'{.
.. j.g
^N Page 3 of 3 4
.,- 2 r
J D
UNIT Sl!U1 DOWNS AND POWER REDUCTIONS il B Robinson Two' Ui A E DATE 820101
,f? H COMPLETED BY H. Rav Norrie A4 REPORT MONTil January TELEPl!ONE _ (803) 38%4524
+
d<
~ - '
7' r.
E E
- 14
_{ 7 3
4Yy Licensee j-r, h
Cause & Cauiective
_'f ~]
y
~ Attion to No.
Date y,
3g
{
jj$
Event
[?
gO g
H R=
s' 2 " =gr Report a mO Prevent Recurrence
~;p.
t e.
o g
u n: 31 6
N.
,1-l' ? i 1
s 01-01 820101 S
0.
,A 4
HB HTEXCH Power Reduction to =80% Due to Steam xl j
f/
Generator Consideration.
f
>r 01-02 820119 S
0 rB 4
HC HTEXCH Power Reduction to =50% Due to
~
Condenser Leaking Tubes e
Were Plugg, Tube Leaks.
'n ed and the Unit Returned 7'
f
~7 to =80% Power.
/~
~
y
.,),
, ~ -
'I J
).-
4 t
2 3
4 1
. Forced Reau n.
Method:
Exlubit G Instrutiions
(
1 F:
S: Scheduled A l'onipmen, Failure ( Lxplain) 1 -Manual for Preparation of Data i
it.M.iinier.ance of Test 2.M.mual Scism.
Entr> Sheets for I.ieensee C. Refueling 3 Autonpiic Scram.
Esen Rep.ni (LLR) Fde (NUREG-
_ f,,
D Repilatin) Resitiction 4 Other (Eatplain) 0161) t -Opesatm Training & License Examination F Adnumstrative 5
G Operational Eeror (Explain)
Exhibit I Same Sourec pl/77)
Il-Other ( Explain) tg