Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19296B395 + (12:42:52, 2 January 2025)
- ML19296B394 + (12:42:53, 2 January 2025)
- 05000333/LER-1980-014-03, /03L-0:on 800116,during Normal Operation,Torus Water Level Limits Exceeded Tech Specs for 20 Minutes. Caused by Testing of HPCI Sys,Adding Water to Torus Via Min Flow Valve.Torus Pumped Down to Tech Spec Limit + (12:42:54, 2 January 2025)
- 05000029/LER-1980-004-03, /03L-0:on 800119,during Scheduled Shutdown,While Performing Secondary Plant Chemistry,Steam Generators 1,3 & 4 Chloride Concentration Was Above 0.5 Ppm.Caused by Steam Generators Chemical Hideout.Generators Drained + (12:42:56, 2 January 2025)
- ML19296B391 + (12:42:58, 2 January 2025)
- 05000336/LER-1980-001, Forwards LER 80-001/03L-0 + (12:42:59, 2 January 2025)
- 05000029/LER-1980-004, Forwards LER 80-004/03L-0 + (12:43:01, 2 January 2025)
- 05000333/LER-1980-014, Forwards LER 80-014/03L-0 + (12:43:03, 2 January 2025)
- ML19296B382 + (12:43:04, 2 January 2025)
- 05000029/LER-1980-003-03, /03L-0:on 800118,while Performing Radioactive Source Inventory & Leak Testing Procedure,Discovered That 121.8 Uci of Cs-137 Sealed Source Had Not Been Inventoried or Leak Tested Since 781213.Caused by Procedural Failure + (12:43:05, 2 January 2025)
- 05000029/LER-1980-003, Forwards LER 80-003/03L-0 + (12:43:10, 2 January 2025)
- ML19296B372 + (12:43:11, 2 January 2025)
- ML19296B367 + (12:43:15, 2 January 2025)
- ML19296B364 + (12:43:16, 2 January 2025)
- 05000282/LER-1980-004-03, /03L-0:on 800118,discovered That Loop a Steam Flow Transmitter Had Drifted Out of Spec.Caused by Failure of Differential Pressure Unit in Barton Flow Transmitter Model 384.Pressure Unit Replaced,Transmitter Recalibr + (12:43:20, 2 January 2025)
- 05000368/LER-1980-006-03, /03L-0:on 800123,during Mode 1 Operation,Core Protection Calculator B Failed,Generating DNBR & Linear Power Density Trips in Primary Power Sys.Cause Undetermined. Channel Restarted & Declared Operable + (12:43:22, 2 January 2025)
- 05000282/LER-1980-004, Forwards LER 80-004/03L-0 + (12:43:24, 2 January 2025)
- 05000368/LER-1980-005-03, /03L-0:on 800123,during Steady State Mode 1 Operation,Reactor Coolant Leakage Calculation Indicated Approx 3.6 Gpm Unidentified Leakage.Caused by Packing on Pressurized Spray Valves Leaking Excessively + (12:43:26, 2 January 2025)
- ML19296B358 + (12:43:28, 2 January 2025)
- 05000368/LER-1980-004-03, /03L-0:on 800107,during Mode 1 Operation,Core Protection Calculator B Failed.Channel B DNBR & Linear Power Density Trips Were Bypassed Placing Reactor Trip Logic in two-out-of-three Trip Sequence.Cause Unknown + (12:43:29, 2 January 2025)
- 05000368/LER-1980-003-03, /03L-0:on 800120,during Mode 3 Operation, Emergency Feedwater Flow Control Valve Failed to Close on Demand.Caused by Lack of Hydraulic Pressure + (12:43:31, 2 January 2025)
- ML19296B354 + (12:43:32, 2 January 2025)
- ML19296B353 + (12:43:33, 2 January 2025)
- ML19296B352 + (12:43:34, 2 January 2025)
- 05000324/LER-1980-014-03, /03L-0:on 800116,during Evolutions,Torus Filled to -25.5 Inches Exceeding -27 Inch Limit.Caused by Operator Error.Operation Procedure OP-17 Revised to Require Second Operator to Monitor Torus + (12:43:35, 2 January 2025)
- ML19296B350 + (12:43:36, 2 January 2025)
- 05000324/LER-1980-014, Forwards LER 80-014/03L-0 + (12:43:37, 2 January 2025)
- 05000324/LER-1980-020-03, /03L-0:on 800123,during Normal operation,2B Reactor Recirculating Pump Tripped.Caused by Blown Fuses. Fuses Replaced & Pump Successfully Restarted + (12:43:39, 2 January 2025)
- ML19296B346 + (12:43:40, 2 January 2025)
- 05000324/LER-1980-020, Forwards LER 80-020/03L-0 + (12:43:41, 2 January 2025)
- 05000325/LER-1980-011-03, /03L-0:on 800121,during 10-minute Run of HPCI Auxiliary Oil Pump,Stoppage Occurred When Switch Moved from Start to Auto Position.Caused by Loose Wire on RTGB Control Switch.Wire Reattached & Tightened + (12:43:43, 2 January 2025)
- 05000325/LER-1980-011, Forwards LER 80-011/03L-0 + (12:43:45, 2 January 2025)
- ML19296B338 + (12:43:46, 2 January 2025)
- ML19296B337 + (12:43:47, 2 January 2025)
- ML19296B335 + (12:43:48, 2 January 2025)
- ML19296B334 + (12:43:49, 2 January 2025)
- ML19296B332 + (12:43:49, 2 January 2025)
- ML19296B331 + (12:43:50, 2 January 2025)
- ML19296B330 + (12:43:50, 2 January 2025)
- ML19296B329 + (12:43:51, 2 January 2025)
- ML19296B328 + (12:43:52, 2 January 2025)
- ML19296B327 + (12:43:52, 2 January 2025)
- ML19296B323 + (12:43:53, 2 January 2025)
- ML19296B325 + (12:43:53, 2 January 2025)
- ML19296B322 + (12:43:54, 2 January 2025)
- ML19296B320 + (12:43:55, 2 January 2025)
- ML19296B317 + (12:43:56, 2 January 2025)
- ML19296B318 + (12:43:56, 2 January 2025)
- ML19296B316 + (12:43:57, 2 January 2025)
- ML19296B314 + (12:43:57, 2 January 2025)
- ML19296B313 + (12:43:58, 2 January 2025)